1
|
Dodevska T, Shterev I. Nanomaterials as catalysts for the sensitive and selective determination of diclofenac. ADMET AND DMPK 2023; 12:151-165. [PMID: 38560716 PMCID: PMC10974820 DOI: 10.5599/admet.2116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 11/15/2023] [Indexed: 04/04/2024] Open
Abstract
Background and purpose Diclofenac (DCF) is a non-steroidal anti-inflammatory drug possessing analgesic and antipyretic properties. It is used for the treatment of rheumatoid arthritis pain, osteoarthritis, and acute muscle pain conditions and can be administrated orally, topically or intravenously. Because of its widespread use, hydrophilicity, stability and poor degradation (bioaccumulation in the food chain), DCF is an emerging chemical contaminant that can cause adverse effects in the ecosystems. Taking into account the consumption of DCF in pharmaceutical formulations and its negative impact on the environment, the development of new sensitive, selective, cheap, fast, and online capable analytical devices is needed for on-site applications. Experimental approach This brief review attempts to cover the recent developments related to the use of nanomaterials as catalysts for electrochemical determination of DCF in pharmaceutical formulations, biological fluids and environmental samples. Key results The article aims to prove how electrochemical sensors represent reliable alternatives to conventional methods for DCF analysis. Conclusion The manuscript highlights the progress in the development of electrochemical sensors for DCF detection. We have analyzed numerous recent papers (mainly since 2019) on sensors developed for the quantitative determination of DCF, indicating the limit of detection, linear range, stability, reproducibility, and analytical applications. Current challenges related to the sensor design and future perspectives are outlined.
Collapse
Affiliation(s)
- Totka Dodevska
- Department of Organic Chemistry and Inorganic Chemistry, University of Food Technologies, Plovdiv, Bulgaria
| | | |
Collapse
|
2
|
Silva RM, da Silva AD, Camargo JR, de Castro BS, Meireles LM, Silva PS, Janegitz BC, Silva TA. Carbon Nanomaterials-Based Screen-Printed Electrodes for Sensing Applications. BIOSENSORS 2023; 13:bios13040453. [PMID: 37185528 PMCID: PMC10136782 DOI: 10.3390/bios13040453] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 03/27/2023] [Accepted: 03/27/2023] [Indexed: 05/17/2023]
Abstract
Electrochemical sensors consisting of screen-printed electrodes (SPEs) are recurrent devices in the recent literature for applications in different fields of interest and contribute to the expanding electroanalytical chemistry field. This is due to inherent characteristics that can be better (or only) achieved with the use of SPEs, including miniaturization, cost reduction, lower sample consumption, compatibility with portable equipment, and disposability. SPEs are also quite versatile; they can be manufactured using different formulations of conductive inks and substrates, and are of varied designs. Naturally, the analytical performance of SPEs is directly affected by the quality of the material used for printing and modifying the electrodes. In this sense, the most varied carbon nanomaterials have been explored for the preparation and modification of SPEs, providing devices with an enhanced electrochemical response and greater sensitivity, in addition to functionalized surfaces that can immobilize biological agents for the manufacture of biosensors. Considering the relevance and timeliness of the topic, this review aimed to provide an overview of the current scenario of the use of carbonaceous nanomaterials in the context of making electrochemical SPE sensors, from which different approaches will be presented, exploring materials traditionally investigated in electrochemistry, such as graphene, carbon nanotubes, carbon black, and those more recently investigated for this (carbon quantum dots, graphitic carbon nitride, and biochar). Perspectives on the use and expansion of these devices are also considered.
Collapse
Affiliation(s)
- Rafael Matias Silva
- Department of Chemistry, Federal University of Viçosa, Viçosa 36570-900, MG, Brazil
| | | | - Jéssica Rocha Camargo
- Laboratory of Sensors, Nanomedicine, and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, SP, Brazil
| | | | - Laís Muniz Meireles
- Federal Center for Technological Education of Minas Gerais, Timóteo 35180-008, MG, Brazil
| | | | - Bruno Campos Janegitz
- Laboratory of Sensors, Nanomedicine, and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, SP, Brazil
| | - Tiago Almeida Silva
- Department of Chemistry, Federal University of Viçosa, Viçosa 36570-900, MG, Brazil
| |
Collapse
|
3
|
Sahragard A, Dvořák M, J. Carrasco-Correa E, Varanasupakul P, Kubáň P, Miró M. Programmable Millifluidic Platform Integrating Automatic Electromembrane Extraction Cleanup and In-Line Electrochemical Detection: A Proof of Concept. ACS Sens 2022; 7:3161-3168. [PMID: 36200176 PMCID: PMC9623577 DOI: 10.1021/acssensors.2c01648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
A fully automatic millifluidic sensing platform coupling in-line nonsupported microelectromembrane extraction (μ-EME) with electrochemical detection (ECD) is herein proposed for the first time. Exploiting the features of the second generation of flow analysis, termed sequential injection (SI), the smart integration of SI and μ-EME-ECD enables (i) the repeatable formation of microvolumes of phases for the extraction step in a membrane-less (nonsupported) arrangement, (ii) diverting the acceptor plug to the ECD sensing device, (iii) in-line pH adjustment before the detection step, and (iv) washing of the platform for efficient removal of remnants of wetting film solvent, all entirely unsupervised. The real-life applicability of the miniaturized sensing system is studied for in-line sample cleanup and ECD of diclofenac as a model analyte after μ-EME of urine as a complex biological sample. A comprehensive study of the merits and the limitations of μ-EME solvents on ECD is presented. Under the optimal experimental conditions using 14 μL of unprocessed urine as the donor, 14 μL of 1-nonanol as the organic phase, and 14 μL of 25 mM NaOH as the acceptor in a 2.4 mm ID PTFE tubing, an extraction voltage of 250 V, and an extraction time of 10 min, an absolute (mass) extraction recovery of 48% of diclofenac in urine is obtained. The proposed flow-through system is proven to efficiently remove the interfering effect of predominantly occurring organic species in human urine on ECD with RSD% less than 8.6%.
Collapse
Affiliation(s)
- Ali Sahragard
- Department
of Chemistry, Faculty of Science, Chulalongkorn
University, Bangkok10330, Thailand
| | - Miloš Dvořák
- Institute
of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, BrnoCZ-60200, Czech Republic
| | - Enrique J. Carrasco-Correa
- CLECEM
group, Department of Analytical Chemistry, University of Valencia, C/Doctor Moliner 50, Burjassot, Valencia46100, Spain
| | - Pakorn Varanasupakul
- Department
of Chemistry, Faculty of Science, Chulalongkorn
University, Bangkok10330, Thailand
| | - Pavel Kubáň
- Institute
of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, BrnoCZ-60200, Czech Republic
| | - Manuel Miró
- FI-TRACE
Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Carretera de Valldemossa km 7.5, Palma de Mallorca, Illes BalearsE-07122, Spain,
| |
Collapse
|
4
|
Tyszczuk-Rotko K, Kozak J, Czech B. Screen-Printed Voltammetric Sensors-Tools for Environmental Water Monitoring of Painkillers. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22072437. [PMID: 35408052 PMCID: PMC9003516 DOI: 10.3390/s22072437] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 03/18/2022] [Accepted: 03/20/2022] [Indexed: 05/03/2023]
Abstract
The dynamic production and usage of pharmaceuticals, mainly painkillers, indicates the growing problem of environmental contamination. Therefore, the monitoring of pharmaceutical concentrations in environmental samples, mostly aquatic, is necessary. This article focuses on applying screen-printed voltammetric sensors for the voltammetric determination of painkillers residues, including non-steroidal anti-inflammatory drugs, paracetamol, and tramadol in environmental water samples. The main advantages of these electrodes are simplicity, reliability, portability, small instrumental setups comprising the three electrodes, and modest cost. Moreover, the electroconductivity, catalytic activity, and surface area can be easily improved by modifying the electrode surface with carbon nanomaterials, polymer films, or electrochemical activation.
Collapse
|
5
|
Kozak J, Tyszczuk-Rotko K, Sadok I, Sztanke K, Sztanke M. Application of a Screen-Printed Sensor Modified with Carbon Nanofibers for the Voltammetric Analysis of an Anticancer Disubstituted Fused Triazinone. Int J Mol Sci 2022; 23:ijms23052429. [PMID: 35269572 PMCID: PMC8910141 DOI: 10.3390/ijms23052429] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 02/18/2022] [Accepted: 02/18/2022] [Indexed: 01/01/2023] Open
Abstract
In this paper, we propose the first analytical procedure—using a screen-printed carbon electrode modified with carbon nanofibers (SPCE/CNFs)—for the detection and quantitative determination of an electroactive disubstituted fused triazinone, namely 4-Cl-PIMT, which is a promising anticancer drug candidate. The electrochemical performances of the sensor were investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square-wave adsorptive stripping voltammetry (SWAdSV). The presence of carbon nanofibers on the sensor surface caused a decrease in charge-transfer resistance and an increase in the active surface compared to the bare SPCE. Under the optimised experimental conditions, the proposed voltammetric procedure possesses a good linear response for the determination of 4-Cl-PIMT in the two linear ranges of 0.5–10 nM and 10–100 nM. The low limits of detection and quantification were calculated at 0.099 and 0.33 nM, respectively. In addition, the sensor displays high reproducibility and repeatability, as well as good selectivity. The selectivity was improved through the use of a flow system and a short accumulation time. The SWAdSV procedure with SPCE/CNFs was applied to determine 4-Cl-PIMT in human serum samples. The SWAdSV results were compared to those obtained by the ultra-high-performance liquid chromatography coupled with electrospray ionization/single-quadrupole mass spectrometry (UHPLC-ESI-MS) method.
Collapse
Affiliation(s)
- Jędrzej Kozak
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland; (J.K.); (K.T.-R.)
| | - Katarzyna Tyszczuk-Rotko
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland; (J.K.); (K.T.-R.)
| | - Ilona Sadok
- Laboratory of Separation and Spectroscopic Method Applications, Centre for Interdisciplinary Research, Faculty of Science and Health, The John Paul II Catholic University of Lublin, 20-708 Lublin, Poland;
| | - Krzysztof Sztanke
- Laboratory of Bioorganic Synthesis and Analysis, Chair and Department of Medical Chemistry, Medical University of Lublin, 4A Chodźki Street, 20-093 Lublin, Poland
- Correspondence:
| | - Małgorzata Sztanke
- Chair and Department of Medical Chemistry, Medical University of Lublin, 4A Chodźki Street, 20-093 Lublin, Poland;
| |
Collapse
|
6
|
Electrochemical Method for Ease Determination of Sodium Diclofenac Trace Levels in Water Using Graphene-Multi-Walled Carbon Nanotubes Paste Electrode. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 19:ijerph19010029. [PMID: 35010286 PMCID: PMC8750901 DOI: 10.3390/ijerph19010029] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 12/16/2021] [Accepted: 12/18/2021] [Indexed: 01/10/2023]
Abstract
Sodium diclofenac (DCF) presence reported in water use cycle at various concentrations including trace levels necessitates continuous development of advanced analytical method for its determination. In this work, ease electrochemical methods for DCF determination based on voltammetric and amperometric techniques were proposed using a simple combination of graphene with multi-walled carbon nanotubes as paste electrode. Integration of the graphene with multi-walled carbon nanotubes enlarged the electroactive surface area of the electrode and implicitly enhanced the electrochemical response for DCF determination. On the basis of the sorption autocatalytic effect manifested at low concentration of DCF, we found that the preconcentration step applied prior to differential-pulsed voltammetry (DPV) and multiple-pulsed amperometry (MPA) allowed for the enhancement of the electroanalytical performance of the DCF electrochemical detections, which were validated by testing in tap water. The lowest limit of detection (LOD) of 1.40 ng·L−1 was found using preconcentration prior to DPV under optimized operating conditions, which is better than that reached by other carbon-based electrodes reported in the literature.
Collapse
|
7
|
Electrochemical Determination of Diclofenac by Using ZIF-67/g-C3N4 Modified Electrode. ADSORPT SCI TECHNOL 2021. [DOI: 10.1155/2021/7896286] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
A facial differential pulse voltammetric procedure using a glassy carbon electrode modified with zeolite imidazolate framework-67/graphitic carbon nitride (ZIF-67/g-C3N4) for the diclofenac (DCF) determination is demonstrated. ZIF-67/g-C3N4 with different mass ratios of the components was synthesized in a self-assembly process. The obtained materials were characterized by using X-ray diffraction, scanning electron microscopy (SEM), EDX-mapping, and nitrogen adsorption/desorption isotherms. The peak current varies linearly with the DCF concentration in the range of 0.2–2.2 μmol·L−1 and has a detection limit of 0.071 μmol·L−1. The modified electrode exhibits acceptable repeatability, reproducibility, and selectivity towards DCF. The proposed electrode allows determining DCF in human urine without pretreatment, and the results are comparable with those determined with HPLC.
Collapse
|
8
|
Boumya W, Taoufik N, Achak M, Bessbousse H, Elhalil A, Barka N. Electrochemical sensors and biosensors for the determination of diclofenac in pharmaceutical, biological and water samples. TALANTA OPEN 2021. [DOI: 10.1016/j.talo.2020.100026] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
|
9
|
Kozak J, Tyszczuk-Rotko K, Wójciak M, Sowa I. Electrochemically Activated Screen-Printed Carbon Sensor Modified with Anionic Surfactant (aSPCE/SDS) for Simultaneous Determination of Paracetamol, Diclofenac and Tramadol. MATERIALS 2021; 14:ma14133581. [PMID: 34206920 PMCID: PMC8269727 DOI: 10.3390/ma14133581] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 06/21/2021] [Accepted: 06/23/2021] [Indexed: 11/18/2022]
Abstract
In this work, an electrochemically activated screen-printed carbon electrode modified with sodium dodecyl sulfate (aSPCE/SDS) was proposed for the simultaneous determination of paracetamol (PA), diclofenac (DF), and tramadol (TR). Changes of surface morphology and electrochemical behaviour of the electrode after the electrochemical activation with H2O2 and SDS surface modification were studied by scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The influence of various parameters on the responses of the aSPCE/SDS such as pH and concentration of the buffer, SDS concentration, and techniques parameters were investigated. Using optimised conditions (Eacc. of −0.4 V, tacc. of 120 s, ΔEA of 150 mV, ν of 250 mV s−1, and tm of 10 ms), the aSPCE/SDS showed a good linear response in the concentration ranges of 5.0 × 10−8–2.0 × 10−5 for PA, 1.0 × 10−9–2.0 × 10−7 for DF, and 1.0 × 10−8–2.0 × 10−7 and 2.0 × 10−7–2.0 × 10−6 mol L−1 for TR. The limits of detection obtained during the simultaneous determination of PA, DF, and TR are 1.49 × 10−8 mol L−1, 2.10 × 10−10 mol L−1, and 1.71 × 10−9 mol L−1, respectively. The selectivity of the aSPCE/SDS was evaluated by examination of the impact of some inorganic and organic substances that are commonly present in environmental and biological samples on the responses of PA, DF, and TR. Finally, the differential pulse adsorptive stripping voltammetric (DPAdSV) procedure using the aSPCE/SDS was successfully applied for the determination of PA, DF, and TR in river water and serum samples as well as pharmaceuticals.
Collapse
Affiliation(s)
- Jędrzej Kozak
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland;
| | - Katarzyna Tyszczuk-Rotko
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland;
- Correspondence: (K.T.-R.); (M.W.)
| | - Magdalena Wójciak
- Department of Analytical Chemistry, Medical University of Lublin, 20-093 Lublin, Poland;
- Correspondence: (K.T.-R.); (M.W.)
| | - Ireneusz Sowa
- Department of Analytical Chemistry, Medical University of Lublin, 20-093 Lublin, Poland;
| |
Collapse
|
10
|
Tyszczuk-Rotko K, Kozak J, Sztanke M, Sztanke K, Sadok I. A Screen-Printed Sensor Coupled with Flow System for Quantitative Determination of a Novel Promising Anticancer Agent Candidate. SENSORS 2020; 20:s20185217. [PMID: 32933116 PMCID: PMC7571158 DOI: 10.3390/s20185217] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Revised: 09/05/2020] [Accepted: 09/11/2020] [Indexed: 11/25/2022]
Abstract
A carbon nanofibers modified screen-printed carbon sensor (SPCE/CNFs) was applied for the determination of a novel promising anticancer agent candidate (ethyl 8-(4-methoxyphenyl)-4-oxo-4,6,7,8-tetrahydroimidazo[2,1-c][1,2,4]triazine-3-carboxylate, EIMTC) using square-wave voltammetry (SWV). It is the first method for the quantitative determination of EIMTC. The modified screen-printed sensor exhibited excellent electrochemical activity in reducing EIMTC. The peak current of EIMTC was found to be linear in two concentration ranges of 2.0 × 10−9 – 2.0 × 10−8 mol L−1 and 2.0 × 10−8 – 2.0 × 10−7 mol L−1, with a detection limit of 5.0 × 10−10 mol L−1. The connection of flow-cell for the SPCE/CNFs with SWV detection allowed for the successful determination of EIMTC in human serum samples. Ultra-high-performance liquid chromatography coupled to electrospray ionization triple quadrupole mass spectrometry (UHPLC-ESI-MS/MS) acted as a comparative method in the serum samples analysis.
Collapse
Affiliation(s)
- Katarzyna Tyszczuk-Rotko
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland;
- Correspondence:
| | - Jędrzej Kozak
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland;
| | - Małgorzata Sztanke
- Chair and Department of Medical Chemistry, Medical University of Lublin, 20-093 Lublin, Poland;
| | - Krzysztof Sztanke
- Laboratory of Bioorganic Synthesis and Analysis, Chair and Department of Medical Chemistry, Medical University of Lublin, 20-093 Lublin, Poland;
| | - Ilona Sadok
- Laboratory of Separation and Spectroscopic Method Application, Centre for Interdisciplinary Research, Faculty of Science and Health, The John Paul II Catholic University of Lublin, 20-708 Lublin, Poland;
| |
Collapse
|
11
|
Simultaneous Analysis of Paracetamol and Diclofenac Using MWCNTs-COOH Modified Screen-Printed Carbon Electrode and Pulsed Potential Accumulation. MATERIALS 2020; 13:ma13143091. [PMID: 32664310 PMCID: PMC7412038 DOI: 10.3390/ma13143091] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 07/02/2020] [Accepted: 07/06/2020] [Indexed: 11/17/2022]
Abstract
A differential-pulse adsorptive stripping voltammetric (DPAdSV) procedure with the use of pulsed potential accumulation and carboxyl functionalized multiwalled carbon nanotubes modified screen-printed carbon electrode (SPCE/MWCNTs-COOH) was delineated for simultaneous analysis of paracetamol (PA) and diclofenac (DF). The use of carboxyl functionalized MWCNTs and pulsed potential accumulation improves the analytical signals of PA and DF, and minimizes interferences from surfactants. After optimization of analytical conditions for this sensor, the peak currents of the two compounds were found to increase linearly with the increase in their concentration (5.0 × 10-9-5.0 × 10-6 mol L-1 with a detection limit of 1.4 × 10-9 mol L-1 for PA, and 1.0 × 10-10-2.0 × 10-8 mol L-1 with a detection limit of 3.0 × 10-11 mol L-1 for DF). For the first time, the electrochemical sensor allows simultaneous determination of PA and DF at concentrations of 24.3 ± 0.5 nmol L-1 and 3.7 ± 0.7 nmol L-1, respectively, in wastewater samples purified in a sewage treatment plant.
Collapse
|
12
|
Carbonaceous Nanomaterials Employed in the Development of Electrochemical Sensors Based on Screen-Printing Technique—A Review. Catalysts 2020. [DOI: 10.3390/catal10060680] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
This paper aims to revise research on carbonaceous nanomaterials used in developing sensors. In general, nanomaterials are known to be useful in developing high-performance sensors due to their unique physical and chemical properties. Thus, descriptions were made for various structural features, properties, and manner of functionalization of carbon-based nanomaterials used in electrochemical sensors. Of the commonly used technologies in manufacturing electrochemical sensors, the screen-printing technique was described, highlighting the advantages of this type of device. In addition, an analysis was performed in point of the various applications of carbon-based nanomaterial sensors to detect analytes of interest in different sample types.
Collapse
|