1
|
Kozak J, Tyszczuk-Rotko K, Keller A, Wójciak M, Sowa I. Activated Screen-Printed Boron-Doped Diamond Electrode for Rapid and Highly Sensitive Determination of Curcumin in Food Products. Materials (Basel) 2023; 16:6826. [PMID: 37959423 PMCID: PMC10649004 DOI: 10.3390/ma16216826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 10/18/2023] [Accepted: 10/20/2023] [Indexed: 11/15/2023]
Abstract
Due to a great interest in the beneficial properties of polyphenolic antioxidant curcumin (CCM), sensitive and accurate methods for determining CCM are needed. The purpose of our research was to develop a very simple, fast, and sensitive differential pulse adsorptive stripping voltammetric (DPAdSV) procedure using an electrochemically activated screen-printed boron-doped diamond electrode (aSPBDDE) for the determination of CCM. The activation of the SPBDDE was accomplished in a solution of 0.1 mol/L NaOH by performing five cyclic voltammetric scans in the range of 0-2 V, at ν of 100 mV/s. The changes in surface morphology and the reduction of the charge transfer resistance due to the activation of the electrode resulted in the amplification of the CCM analytical signal on the aSPBDDE. As a result, an extremely sensitive measurement tool was formed, which under optimized conditions (0.025 mol/L PBS of pH = 2.6, Eacc of 0.3 V, tacc of 90 s, ΔEA of 100 mV, ν of 150 mV/s, and tm of 10 ms) allowed us to obtain a limit of detection (LOD) of 5.0 × 10-13 mol/L. The aSPBDDE has proven to be a highly effective tool for the direct determination of CCM in food samples with high accuracy and precision. The results are in agreement with those obtained using ultra-high-performance liquid chromatography coupled with mass spectrometry and electrospray ionization (UHPLC-ESI/MS).
Collapse
Affiliation(s)
- Jędrzej Kozak
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland
| | - Katarzyna Tyszczuk-Rotko
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland
| | - Aleksy Keller
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland
| | - Magdalena Wójciak
- Department of Analytical Chemistry, Medical University of Lublin, 20-093 Lublin, Poland
| | - Ireneusz Sowa
- Department of Analytical Chemistry, Medical University of Lublin, 20-093 Lublin, Poland
| |
Collapse
|
2
|
Brun E, Cottinet PJ, Pelletier A, Ducharne B. Printed Eddy Current Testing Sensors: Toward Structural Health Monitoring Applications. Sensors (Basel) 2023; 23:8345. [PMID: 37837175 PMCID: PMC10575164 DOI: 10.3390/s23198345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 10/02/2023] [Accepted: 10/07/2023] [Indexed: 10/15/2023]
Abstract
Reliable measurements in structural health monitoring mean for the instrumentation to be set in perfect reproducible conditions. The solution described in this study consists of printing the sensors directly on the parts to be controlled. This method solves the reproducibility issue, limits human error, and can be used in confined or hazardous environments. This work was limited to eddy current testing, but the settings and conclusions are transposable to any non-destructive testing methods (ultrasounds, etc.). The first salve of tests was run to establish the best dielectric and conductive ink combination. The Dupont ink combination gave the best performances. Then, the dispenser- and the screen-printing methods were carried out to print flat spiral coils on flexible substrates. The resulting sensors were compared to flex-printed circuit boards (PCB-flex) using copper for the electrical circuit. The conductive ink methods were revealed to be just as efficient. The last stage of this work consisted of printing sensors on solid parts. For this, 20-turn spiral coils were printed on 3 mm thick stainless-steel plates. The permanent sensors showed good sensibility in the same range as the portative ones, demonstrating the method's feasibility.
Collapse
Affiliation(s)
- Eliott Brun
- LGEF, INSA-Lyon, EA682, University Lyon, 69621 Villeurbanne, France; (E.B.); (P.-J.C.)
| | - Pierre-Jean Cottinet
- LGEF, INSA-Lyon, EA682, University Lyon, 69621 Villeurbanne, France; (E.B.); (P.-J.C.)
| | | | - Benjamin Ducharne
- ELyTMaX UMI 3757, CNRS, Univ. Lyon, INSA Lyon, Centrale Lyon, Université Claude Bernard Lyon 1, Tohoku University, Sendai 980-8577, Japan
| |
Collapse
|
3
|
Kozak J, Tyszczuk-Rotko K, Sztanke K, Sztanke M. Sensitive and Selective Voltammetric Sensor Based on Anionic Surfactant-Modified Screen-Printed Carbon for the Quantitative Analysis of an Anticancer Active Fused Azaisocytosine-Containing Congener. Int J Mol Sci 2022; 24. [PMID: 36614007 DOI: 10.3390/ijms24010564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 12/23/2022] [Accepted: 12/27/2022] [Indexed: 12/30/2022] Open
Abstract
3-(4-Nitrophenyl)-8-(2,3-dimethylphenyl)-7,8-dihydroimidazo[2,1-c][1,2,4]triazin-4(6H)-one (NDIT) is one of the most promising candidates for anticancer agents. Hence, a sensitive and selective sodium dodecyl sulfate-modified screen-printed carbon sensor (SPCE/SDS) was used for its quantitative analysis. The SPCE/SDS, in contrast to the SPCE, showed excellent behavior in the electrochemical reduction of NDIT by differential-pulse adsorptive stripping voltammetry (DPAdSV). Cyclic voltammetric (CV) studies reveal an irreversible, two-stage and not purely diffusion-controlled reduction process in 0.01 M HNO3. The sensor was characterized by CV and electrochemical impedance spectroscopy (EIS). Under the optimized conditions (t 45 s, ΔE 175 mV, ν 150 mV/s, and tm 5 ms), the DPAdSV procedure with the SPCE/SDS presented a very wide linear range from 1 to 2000 nM and a low detection limit of 0.29 nM. A 1000-fold excess concentration of potential interferents commonly present in biological samples did not significantly alter the peak current of NDIT. The practical application of the proposed DPAdSV procedure with the SPCE/SDS was successfully checked by analyzing spiked human serum samples.
Collapse
|
4
|
Matvieiev O, Šelešovská R, Vojs M, Marton M, Michniak P, Hrdlička V, Hatala M, Janíková L, Chýlková J, Skopalová J, Cankař P, Navrátil T. Novel Screen-Printed Sensor with Chemically Deposited Boron-Doped Diamond Electrode: Preparation, Characterization, and Application. Biosensors (Basel) 2022; 12:bios12040241. [PMID: 35448301 PMCID: PMC9027657 DOI: 10.3390/bios12040241] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 04/08/2022] [Accepted: 04/11/2022] [Indexed: 05/27/2023]
Abstract
New screen-printed sensor with a boron-doped diamond working electrode (SP/BDDE) was fabricated using a large-area linear antenna microwave chemical deposition vapor system (LA-MWCVD) with a novel precursor composition. It combines the advantages of disposable printed sensors, such as tailored design, low cost, and easy mass production, with excellent electrochemical properties of BDDE, including a wide available potential window, low background currents, chemical resistance, and resistance to passivation. The newly prepared SP/BDDEs were characterized by scanning electron microscopy (SEM) and Raman spectroscopy. Their electrochemical properties were investigated by cyclic voltammetry and electrochemical impedance spectroscopy using inner sphere ([Fe(CN)6]4-/3-) and outer sphere ([Ru(NH3)6]2+/3+) redox probes. Moreover, the applicability of these new sensors was verified by analysis of the anti-inflammatory drug lornoxicam in model and pharmaceutical samples. Using optimized differential pulse voltammetry in Britton-Robinson buffer of pH 3, detection limits for lornoxicam were 9 × 10-8 mol L-1. The oxidation mechanism of lornoxicam was investigated using bulk electrolysis and online electrochemical cell with mass spectrometry; nine distinct reaction steps and corresponding products and intermediates were identified.
Collapse
Affiliation(s)
- Oleksandr Matvieiev
- Institute of Environmental and Chemical Engineering, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic; (O.M.); (L.J.); (J.C.)
| | - Renáta Šelešovská
- Institute of Environmental and Chemical Engineering, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic; (O.M.); (L.J.); (J.C.)
| | - Marian Vojs
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 812 19 Bratislava, Slovakia; (M.V.); (M.M.); (P.M.)
| | - Marián Marton
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 812 19 Bratislava, Slovakia; (M.V.); (M.M.); (P.M.)
| | - Pavol Michniak
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 812 19 Bratislava, Slovakia; (M.V.); (M.M.); (P.M.)
| | - Vojtěch Hrdlička
- J. Heyrovsky Institute of Physical Chemistry of the Academy of Sciences of the Czech Republic, Dolejškova 3, 182 23 Prague, Czech Republic;
| | - Michal Hatala
- Department of Graphic Arts Technology and Applied Photochemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 812 37 Bratislava, Slovakia;
| | - Lenka Janíková
- Institute of Environmental and Chemical Engineering, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic; (O.M.); (L.J.); (J.C.)
| | - Jaromíra Chýlková
- Institute of Environmental and Chemical Engineering, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 532 10 Pardubice, Czech Republic; (O.M.); (L.J.); (J.C.)
| | - Jana Skopalová
- Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, 17. listopadu 1192/12, 779 00 Olomouc, Czech Republic;
| | - Petr Cankař
- Department of Organic Chemistry, Faculty of Science, Palacký University in Olomouc, 17. listopadu 1192/12, 779 00 Olomouc, Czech Republic;
| | - Tomáš Navrátil
- J. Heyrovsky Institute of Physical Chemistry of the Academy of Sciences of the Czech Republic, Dolejškova 3, 182 23 Prague, Czech Republic;
| |
Collapse
|
5
|
Tyszczuk-Rotko K, Kozak J, Czech B. Screen-Printed Voltammetric Sensors-Tools for Environmental Water Monitoring of Painkillers. Sensors (Basel) 2022; 22:s22072437. [PMID: 35408052 PMCID: PMC9003516 DOI: 10.3390/s22072437] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 03/18/2022] [Accepted: 03/20/2022] [Indexed: 05/03/2023]
Abstract
The dynamic production and usage of pharmaceuticals, mainly painkillers, indicates the growing problem of environmental contamination. Therefore, the monitoring of pharmaceutical concentrations in environmental samples, mostly aquatic, is necessary. This article focuses on applying screen-printed voltammetric sensors for the voltammetric determination of painkillers residues, including non-steroidal anti-inflammatory drugs, paracetamol, and tramadol in environmental water samples. The main advantages of these electrodes are simplicity, reliability, portability, small instrumental setups comprising the three electrodes, and modest cost. Moreover, the electroconductivity, catalytic activity, and surface area can be easily improved by modifying the electrode surface with carbon nanomaterials, polymer films, or electrochemical activation.
Collapse
|
6
|
Kozak J, Tyszczuk-Rotko K, Sadok I, Sztanke K, Sztanke M. Application of a Screen-Printed Sensor Modified with Carbon Nanofibers for the Voltammetric Analysis of an Anticancer Disubstituted Fused Triazinone. Int J Mol Sci 2022; 23:ijms23052429. [PMID: 35269572 PMCID: PMC8910141 DOI: 10.3390/ijms23052429] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 02/18/2022] [Accepted: 02/18/2022] [Indexed: 01/01/2023] Open
Abstract
In this paper, we propose the first analytical procedure—using a screen-printed carbon electrode modified with carbon nanofibers (SPCE/CNFs)—for the detection and quantitative determination of an electroactive disubstituted fused triazinone, namely 4-Cl-PIMT, which is a promising anticancer drug candidate. The electrochemical performances of the sensor were investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square-wave adsorptive stripping voltammetry (SWAdSV). The presence of carbon nanofibers on the sensor surface caused a decrease in charge-transfer resistance and an increase in the active surface compared to the bare SPCE. Under the optimised experimental conditions, the proposed voltammetric procedure possesses a good linear response for the determination of 4-Cl-PIMT in the two linear ranges of 0.5–10 nM and 10–100 nM. The low limits of detection and quantification were calculated at 0.099 and 0.33 nM, respectively. In addition, the sensor displays high reproducibility and repeatability, as well as good selectivity. The selectivity was improved through the use of a flow system and a short accumulation time. The SWAdSV procedure with SPCE/CNFs was applied to determine 4-Cl-PIMT in human serum samples. The SWAdSV results were compared to those obtained by the ultra-high-performance liquid chromatography coupled with electrospray ionization/single-quadrupole mass spectrometry (UHPLC-ESI-MS) method.
Collapse
Affiliation(s)
- Jędrzej Kozak
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland; (J.K.); (K.T.-R.)
| | - Katarzyna Tyszczuk-Rotko
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland; (J.K.); (K.T.-R.)
| | - Ilona Sadok
- Laboratory of Separation and Spectroscopic Method Applications, Centre for Interdisciplinary Research, Faculty of Science and Health, The John Paul II Catholic University of Lublin, 20-708 Lublin, Poland;
| | - Krzysztof Sztanke
- Laboratory of Bioorganic Synthesis and Analysis, Chair and Department of Medical Chemistry, Medical University of Lublin, 4A Chodźki Street, 20-093 Lublin, Poland
- Correspondence:
| | - Małgorzata Sztanke
- Chair and Department of Medical Chemistry, Medical University of Lublin, 4A Chodźki Street, 20-093 Lublin, Poland;
| |
Collapse
|
7
|
Dăscălescu D, Apetrei C. Voltammetric Determination of Levodopa Using Mesoporous Carbon-Modified Screen-Printed Carbon Sensors. Sensors (Basel) 2021; 21:6301. [PMID: 34577507 DOI: 10.3390/s21186301] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 09/16/2021] [Accepted: 09/17/2021] [Indexed: 12/11/2022]
Abstract
Levodopa is a precursor of dopamine, having important beneficial effects in the treatment of Parkinson’s disease. In this study, levodopa was accurately detected by means of cyclic voltammetry using carbon-based (C-SPCE), mesoporous carbon (MC-SPCE) and ordered mesoporous carbon (OMC-SPCE)-modified screen-printed sensors. Screen-printed carbon sensors were initially used for the electrochemical detection of levodopa in a 10−3 M solution at pH 7.0. The mesoporous carbon with an organized structure led to better electroanalysis results and to lower detection and quantification limits of the OMC-SPCE sensor as compared to the other two studied sensors. The range of linearity obtained and the low values of the detection (0.290 µM) and quantification (0.966 µM) limit demonstrate the high sensitivity and accuracy of the method for the determination of levodopa in real samples. Therefore, levodopa was detected by means of OMC-SPCE in three dietary supplements produced by different manufacturers and having various concentrations of the active compound, levodopa. The results obtained by cyclic voltammetry were compared with those obtained by using the FTIR method and no significant differences were observed. OMC-SPCE proved to be stable, and the electrochemical responses did not vary by more than 3% in repeated immersions in a solution with the same concentration of levodopa. In addition, the interfering compounds did not significantly influence the peaks related to the presence of levodopa in the solution to be analyzed.
Collapse
|
8
|
Tyszczuk-Rotko K, Kozak J, Sztanke M, Sztanke K, Sadok I. A Screen-Printed Sensor Coupled with Flow System for Quantitative Determination of a Novel Promising Anticancer Agent Candidate. Sensors (Basel) 2020; 20:s20185217. [PMID: 32933116 PMCID: PMC7571158 DOI: 10.3390/s20185217] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Revised: 09/05/2020] [Accepted: 09/11/2020] [Indexed: 11/25/2022]
Abstract
A carbon nanofibers modified screen-printed carbon sensor (SPCE/CNFs) was applied for the determination of a novel promising anticancer agent candidate (ethyl 8-(4-methoxyphenyl)-4-oxo-4,6,7,8-tetrahydroimidazo[2,1-c][1,2,4]triazine-3-carboxylate, EIMTC) using square-wave voltammetry (SWV). It is the first method for the quantitative determination of EIMTC. The modified screen-printed sensor exhibited excellent electrochemical activity in reducing EIMTC. The peak current of EIMTC was found to be linear in two concentration ranges of 2.0 × 10−9 – 2.0 × 10−8 mol L−1 and 2.0 × 10−8 – 2.0 × 10−7 mol L−1, with a detection limit of 5.0 × 10−10 mol L−1. The connection of flow-cell for the SPCE/CNFs with SWV detection allowed for the successful determination of EIMTC in human serum samples. Ultra-high-performance liquid chromatography coupled to electrospray ionization triple quadrupole mass spectrometry (UHPLC-ESI-MS/MS) acted as a comparative method in the serum samples analysis.
Collapse
Affiliation(s)
- Katarzyna Tyszczuk-Rotko
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland;
- Correspondence:
| | - Jędrzej Kozak
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland;
| | - Małgorzata Sztanke
- Chair and Department of Medical Chemistry, Medical University of Lublin, 20-093 Lublin, Poland;
| | - Krzysztof Sztanke
- Laboratory of Bioorganic Synthesis and Analysis, Chair and Department of Medical Chemistry, Medical University of Lublin, 20-093 Lublin, Poland;
| | - Ilona Sadok
- Laboratory of Separation and Spectroscopic Method Application, Centre for Interdisciplinary Research, Faculty of Science and Health, The John Paul II Catholic University of Lublin, 20-708 Lublin, Poland;
| |
Collapse
|
9
|
Papadopoulos F, Diamanteas K, Economou A, Kokkinos C. Rapid Drop-Volume Electrochemical Detection of the "Date Rape" Drug Flunitrazepam in Spirits Using a Screen-Printed Sensor in a Dry-Reagent Format. Sensors (Basel) 2020; 20:s20185192. [PMID: 32933037 PMCID: PMC7570630 DOI: 10.3390/s20185192] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 09/08/2020] [Accepted: 09/08/2020] [Indexed: 06/11/2023]
Abstract
Flunitrazepam is an extremely potent benzodiazepine sedative which is associated with "drug-facilitated sexual assault" when administered within an alcoholic drink. This work describes a simple electrochemical method for on-site rapid detection of flunitrazepam in untreated spirits (whiskey, vodka and gin) using a single-use screen-printed sensor (featuring graphite working and auxiliary electrodes and an Ag/AgCl reference electrode) in a dry reagent format. Analysis was performed by placing a drop of sample on the sensor, which was previously coated with dry KCl, and recording selected reduction/oxidation peaks of the target compound in a cyclic voltammetry scan. The limit of quantification of flunitrazepam was at the sub-mg L-1 range. The between-sensor % relative standard deviation of the analytically useful reduction peak in a solution containing 11.4 mg L-1 flunitrazepam was 9.8% (n = 5). Quantification was performed using calibration curves constructed from pooled samples spiked with flunitrazepam with relative errors <15%. The main advantages of the methodology are that it involves no sample pretreatment (such as deoxygenation, extraction or reagent(s) addition) and requires only drop-sized volumes of the sample, thus facilitating rapid on-site screening using portable equipment.
Collapse
|
10
|
Hauke A, Oertel S, Knoke L, Fein V, Maier C, Brinkmann F, Jank MPM. Screen-Printed Sensor for Low-Cost Chloride Analysis in Sweat for Rapid Diagnosis and Monitoring of Cystic Fibrosis. Biosensors (Basel) 2020; 10:bios10090123. [PMID: 32933070 PMCID: PMC7558764 DOI: 10.3390/bios10090123] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 09/01/2020] [Accepted: 09/07/2020] [Indexed: 02/06/2023]
Abstract
Analysis of sweat chloride levels in cystic fibrosis (CF) patients is essential not only for diagnosis but also for the monitoring of therapeutic responses to new drugs, such as cystic fibrosis transmembrane conductance regulator (CFTR) modulators and potentiators. Using iontophoresis as the gold standard can cause complications like burns, is uncomfortable, and requires repetitive hospital visits, which can be particularly problematic during a pandemic, where distancing and hygiene requirements are increased; therefore, it is necessary to develop fast and simple measures for the diagnosis and monitoring of CF. A screen-printed, low-cost chloride sensor was developed to remotely monitor CF patients. Using potentiometric measurements, the performance of the sensor was tested. It showed good sensitivity and a detection limit of 2.7 × 10-5 mol/L, which covered more than the complete concentration range of interest for CF diagnosis. Due to its fast response of 30 s, it competes well with standard sensor systems. It also offers significantly reduced costs and can be used as a portable device. The analysis of real sweat samples from healthy subjects, as well as CF patients, demonstrates a proper distinction using the screen-printed sensor. This approach presents an attractive remote measurement alternative for fast, simple, and low-cost CF diagnosis and monitoring.
Collapse
Affiliation(s)
- Alicia Hauke
- Fraunhofer Institute for Integrated Systems and Device Technology, 91058 Erlangen, Germany; (S.O.); (M.P.M.J.)
- Correspondence:
| | - Susanne Oertel
- Fraunhofer Institute for Integrated Systems and Device Technology, 91058 Erlangen, Germany; (S.O.); (M.P.M.J.)
| | - Leona Knoke
- Department of Paediatric Pneumology, University Children’s Hospital, Ruhr-University Bochum, 44791 Bochum, Germany; (L.K.); (V.F.); (C.M.); (F.B.)
| | - Vanessa Fein
- Department of Paediatric Pneumology, University Children’s Hospital, Ruhr-University Bochum, 44791 Bochum, Germany; (L.K.); (V.F.); (C.M.); (F.B.)
| | - Christoph Maier
- Department of Paediatric Pneumology, University Children’s Hospital, Ruhr-University Bochum, 44791 Bochum, Germany; (L.K.); (V.F.); (C.M.); (F.B.)
| | - Folke Brinkmann
- Department of Paediatric Pneumology, University Children’s Hospital, Ruhr-University Bochum, 44791 Bochum, Germany; (L.K.); (V.F.); (C.M.); (F.B.)
| | - Michael P. M. Jank
- Fraunhofer Institute for Integrated Systems and Device Technology, 91058 Erlangen, Germany; (S.O.); (M.P.M.J.)
| |
Collapse
|
11
|
Kostelnik A, Kopel P, Cegan A, Pohanka M. Construction of an Acetylcholinesterase Sensor Based on Synthesized Paramagnetic Nanoparticles, a Simple Tool for Neurotoxic Compounds Assay. Sensors (Basel) 2017; 17:E676. [PMID: 28338634 DOI: 10.3390/s17040676] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 03/20/2017] [Accepted: 03/22/2017] [Indexed: 12/27/2022]
Abstract
Magnetic particles (MPs) have been widely used in biological applications in recent years as a carrier for various molecules. Their big advantage is in repeated use of immobilized molecules including enzymes. Acetylcholinesterase (AChE) is an enzyme playing crucial role in neurotransmission and the enzyme is targeted by various molecules like Alzheimer's drugs, pesticides and warfare agents. In this work, an electrochemical biosensor having AChE immobilized onto MPs and stabilized through glutaraldehyde (GA) molecule was proposed for assay of the neurotoxic compounds. The prepared nanoparticles were modified by pure AChE and they were used for the measurement anti-Alzheimer's drug galantamine and carbamate pesticide carbofuran with limit of detection 1.5 µM and 20 nM, respectively. All measurements were carried out using screen-printed sensor with carbon working, silver reference, and carbon auxiliary electrode. Standard Ellman's assay was used for validation measurement of both inhibitors. Part of this work was the elimination of reversible inhibitors represented by galantamine from the active site of AChE. For this purpose, we used a lower pH to get the original activity of AChE after inhibition by galantamine. We also observed decarbamylation of the AChE-carbofuran adduct. Influence of organic solvents to AChE as well as repeatability of measurement with MPs with AChE was also established.
Collapse
|