1
|
Song J, Guan K. The Impact of Piano Game-Based Learning on the Mental Health of Elderly Individuals. J Nerv Ment Dis 2025; 213:82-89. [PMID: 39894963 DOI: 10.1097/nmd.0000000000001820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2025]
Abstract
ABSTRACT The main research purpose was to investigate the impact of piano courses on the mental health of the elderly. The sample consisted of 30 individuals. The age range of the participants was from 60 to 70 years. For 6 months, the respondents had piano lessons two times a week. One lesson lasted 2 hours and included the development of playing skills and improvisation techniques. The results confirmed the validity of the proposed learning strategy. The Taylor anxiety scale decreased by 19 points. These results showed a decrease of more than half of its original value. The Beck test for depression decreased by 21.5 points. The result shows a decrease two times. The test on the emotional background (the WAM questionnaire) shows an improvement in Well-Being by 3.3 points. In the group of respondents, Activity increased by 3.3 points, and the Mood factor increased by 3.5 points. The direction of further research should be related to the study of the impact of musical practices on various components of the clinical picture of depression and negative emotional states. The results can find practical implementation in the practice of psychotherapeutic work in reducing anxiety and eliminating depression in the elderly in clinics, hospitals, and other medical institutions.
Collapse
Affiliation(s)
- Jie Song
- College of Music, Guangzhou College of Technology and Business, Guangzhou, China
| | | |
Collapse
|
2
|
Salehi MRP, Reisi J, Marandi SM, Abdollahi M. Effect of Whole-Body Electrical Muscle Stimulation Training on Inflammatory and Anti-inflammatory Cytokines in Overweight Men. J Obes Metab Syndr 2024; 33:270-274. [PMID: 39317384 PMCID: PMC11443329 DOI: 10.7570/jomes23070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 03/29/2024] [Accepted: 09/19/2024] [Indexed: 09/26/2024] Open
Abstract
BACKGROUND The aim of this study was to investigate the effects of whole-body electrical muscle stimulation (WB-EMS) training on inflammatory and anti-inflammatory cytokines in overweight men. METHODS We divided 30 participants into EMS and control groups. The training program for the EMS group comprised 20 WB-EMS sessions (7 weeks, three sessions per week). RESULTS The results showed that EMS training caused significant increase in interferon γ (P<0.001) and interleukin 10 (IL-10; P<0.01) and significant decrease in IL-17 and IL-23 (P<0.05). Also, the lipid profile showed significant positive changes in the EMS training group. CONCLUSION EMS training, a novel exercise method that uses electric stimulation, can affect the levels of various cytokines that are involved in inflammation and immunity. EMS training can have both beneficial and harmful effects on the body depending on the type and balance of involved cytokines.
Collapse
Affiliation(s)
| | - Jalil Reisi
- Department of Exercise Physiology, Faculty of Sport Sciences, University of Isfahan, Isfahan, Iran
| | - Sayed Mohammad Marandi
- Department of Exercise Physiology, Faculty of Sport Sciences, University of Isfahan, Isfahan, Iran
| | - Milad Abdollahi
- Department of Exercise Physiology, Faculty of Sport Sciences, University of Isfahan, Isfahan, Iran
| |
Collapse
|
3
|
Beier M, Schoene D, Kohl M, von Stengel S, Uder M, Kemmler W. Non-Athletic Cohorts Enrolled in Longitudinal Whole-Body Electromyostimulation Trials-An Evidence Map. SENSORS (BASEL, SWITZERLAND) 2024; 24:972. [PMID: 38339689 PMCID: PMC10857049 DOI: 10.3390/s24030972] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 01/25/2024] [Accepted: 01/26/2024] [Indexed: 02/12/2024]
Abstract
Whole-body electromyostimulation (WB-EMS) can be considered as a time-efficient, joint-friendly, and highly customizable training technology that attracts a wide range of users. The present evidence map aims to provide an overview of different non-athletic cohorts addressed in WB-EMS research. Based on a comprehensive systematic search according to PRISMA, eighty-six eligible longitudinal trials were identified that correspond with our eligibility criteria. In summary, WB-EMS research sufficiently covers all adult age categories in males and females. Most cohorts addressed (58%) were predominately or exclusively overweight/obese, and in about 60% of them, diseases or conditions were inclusion criteria for the trials. Cohorts specifically enrolled in WB-EMS trials suffer from cancer/neoplasm (n = 7), obesity (n = 6), diabetes mellitus (n = 5), metabolic syndrome (n = 2), nervous system diseases (n = 2), chronic heart failure (n = 4), stroke (n = 1), peripheral arterial diseases (n = 2), knee arthrosis (n = 1), sarcopenia (n = 3), chronic unspecific low back pain (n = 4), and osteopenia (n = 3). Chronic kidney disease was an eligibility criterion in five WB-EMS trials. Finally, three studies included only critically ill patients, and two further studies considered frailty as an inclusion criterion. Of importance, no adverse effects of the WB-EMS intervention were reported. In summary, the evidence gaps in WB-EMS research were particular evident for cohorts with diseases of the nervous and cerebrovascular system.
Collapse
Affiliation(s)
- Miriam Beier
- Institute of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany; (M.B.); (D.S.); (S.v.S.); (M.U.)
| | - Daniel Schoene
- Institute of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany; (M.B.); (D.S.); (S.v.S.); (M.U.)
| | - Matthias Kohl
- Department of Medical and Life Sciences, University of Furtwangen, 78056 Villingen-Schwenningen, Germany;
| | - Simon von Stengel
- Institute of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany; (M.B.); (D.S.); (S.v.S.); (M.U.)
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany; (M.B.); (D.S.); (S.v.S.); (M.U.)
| | - Wolfgang Kemmler
- Institute of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany; (M.B.); (D.S.); (S.v.S.); (M.U.)
- Institute of Medical Physics, Friedrich-Alexander University of Erlangen-Nürnberg, 91052 Erlangen, Germany
| |
Collapse
|
4
|
Sugiharto, Merawati D, Pranoto A, Susanto H. Physiological response of endurance exercise as a growth hormone mediator in adolescent women's. J Basic Clin Physiol Pharmacol 2023; 34:61-67. [PMID: 35499967 DOI: 10.1515/jbcpp-2022-0060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Accepted: 04/09/2022] [Indexed: 01/29/2023]
Abstract
OBJECTIVES Overweight status decreases the growth hormone (GH) secretion, thus, increasing the risk factors for medical complications. However, proper exercise is reported to enhance GH and affect the energy balance. Therefore, exercise is proclaimed to be an accurate and engaging therapy to increase GH in preventing overweight. This study aims to investigate the physiological response of exercise in mediating the increase of GH secretion in female adolescents. METHODS 22 overweight women aged 19-20 years old, with maximal oxygen consumption of 27-35 mL/kg/min, were selected as sample size. They were divided into three groups, namely (CONT, n=7) Control, (MIEE, n=7) Moderate-intensity interval endurance exercise, and (MCEE, n=8) Moderate-intensity continuous endurance exercise. The exercise was carried out by running for 30-35 min using treadmills with an intensity of 60-70% HRmax. The blood sampling for GH examination was carried out four times before exercise, 10 min, 6 h, and 24 h after exercise. The enzyme-linked immunosorbent assay (ELISA) was used to measure the GH and IGF-1 levels. The data analysis was carried out using a one-way ANOVA test, with a significance level of 5%. RESULTS The results of the one-Way ANOVA test suggested a significantly different average GH and IGF-1 before and after the exercise between the three groups (CON, MIEE, and MCEE) (p≤0.05). CONCLUSIONS MCEE increases the GH and IGF-1 levels more considerably than MIEE. Therefore, exercise is a mediator to increase GH and IGF-1 secretion in overweight individuals. Exercise could be a viable therapy for overweight people.
Collapse
Affiliation(s)
- Sugiharto
- Department of Sport Science, Faculty of Sport Science, Universitas Negeri Malang, Malang, Indonesia
| | - Desiana Merawati
- Department of Sport Science, Faculty of Sport Science, Universitas Negeri Malang, Malang, Indonesia
| | - Adi Pranoto
- Doctoral Program of Medical Science, Faculty of Medicine, Universitas Airlangga, Surabaya, Indonesia
| | - Hendra Susanto
- Department of Biology, Faculty of Mathematics and Natural Sciences, Universitas Negeri Malang, Malang, Indonesia
| |
Collapse
|
5
|
Bibliometric Analysis of Studies on Whole Body Electromyostimulation. BIOLOGY 2022; 11:biology11081205. [PMID: 36009832 PMCID: PMC9405447 DOI: 10.3390/biology11081205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 08/05/2022] [Accepted: 08/08/2022] [Indexed: 11/17/2022]
Abstract
Simple Summary This work consists of a review with bibliometric analysis on WB-EMS. One hundred and two articles were analyzed in the period from 2010 to 2022 to find out which country, author and institutions produce the most knowledge on this topic. The results of this work are important to know to determine publication growth trend as well as the most relevant clusters and authors. Abstract Whole Body Electromyostimulation [WB-EMS] is a training methodology that applies electrostimulation in the main muscle groups of the human body superimposed with active training exercises. This study aims to carry out a bibliometric analysis on WB-EMS to provide an overview of the state of research and provide new insights for research in the field. Method: One hundred and two citations extracted were examined using a bibliometric approach based on data stored in the Web of Science Core Collection, applying traditional bibliometric laws, and using VOSviewer and excel for data and metadata processing. Results: Among the results, this study points out that Germany is the country that produces more scientific knowledge on WB-EMS. Wolfgang Kemmler is the most relevant author in this field. Moreover, Frontier of Physiology is the journal where the authors publish the most. Conclusion: Research on WB-EMS has been growing in recent years. German and Spanish researchers lead two clusters where most studies and collaborations in this field are carried out. These findings will provide a better understanding of the state of WB-EMS research and may guide the emergence of new lines of investigation and research ideas.
Collapse
|
6
|
Bloeckl J, Raps S, Weineck M, Kob R, Bertsch T, Kemmler W, Schoene D. Feasibility and Safety of Whole-Body Electromyostimulation in Frail Older People—A Pilot Trial. Front Physiol 2022; 13:856681. [PMID: 35812334 PMCID: PMC9263209 DOI: 10.3389/fphys.2022.856681] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 05/30/2022] [Indexed: 01/04/2023] Open
Abstract
Whole-body electromyostimulation (WB-EMS) induces high-intense stimuli to skeletal muscles with low strain on joints and the autonomic nervous system and may thus be suitable for frail, older people. However, if trained at very high intensities, WB-EMS may damage muscles and kidneys (rhabdomyolysis). This study aimed at investigating the feasibility, safety and preliminary efficacy of WB-EMS in frail, older people. Seven frail (81.3 ± 3.5 years), 11 robust (79.5 ± 3.6 years), 10 young (29.1 ± 6.4 years) participants completed an eight-week WB-EMS training (week 1–4: 1x/week; week 5–8: 1.5x/week) consisting of functional exercises addressing lower extremity strength and balance. Feasibility was assessed using recruitment, adherence, retention, and dropout rates. The satisfaction with WB-EMS was measured using the Physical Activity Enjoyment Scale for older adults (PACES-8). In week 1, 3, and 8 creatine kinase (CK) was assessed immediately before, 48 and 72 h after WB-EMS. Symptoms of rhabdomyolysis (muscle pain, muscle weakness, myoglobinuria) and adverse events were recorded. Functional capacity was assessed at baseline and after 8 weeks using the Short Physical Performance Battery (SPPB), Timed Up-and-Go Test (TUG), Choice Stepping Reaction Time Test (CSRT), 30-second Chair-Stand Test (30-STS), maximum isometric leg strength and handgrip strength. The recruitment rate of frail individuals was 46.2%, adherence 88.3% and the dropout rate 16.7%. All groups indicated a high satisfaction with WB-EMS. CK activity was more pronounced in young individuals with significant changes over time. Within older people CK increased borderline-significantly in the frail group from baseline to week 1 but not afterwards. In robust individuals CK increased significantly from baseline to week 1 and 3. No participant reached CK elevations close to the threshold of ≥5,000 U/l and no symptoms of rhabdomyolysis were observed. With the exception of the TUG (p = 0.173), frail individuals improved in all tests of functional capacity. Compared to the young and robust groups, frail individuals showed the greater improvements in the SPPB, handgrip strength, maximum isokinetic hip-/knee extension and flexion strength. WB-EMS is feasible for frail older people. There were no clinical signs of exertional rhabdomyolysis. WB-EMS proved to be sufficiently intense to induce meaningful changes in functional capacity with frail individuals showing greater improvements for several measures.
Collapse
Affiliation(s)
- Joerg Bloeckl
- Institute of Medical Physics, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany
- *Correspondence: Joerg Bloeckl,
| | - Sebastian Raps
- Institute of Medical Physics, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany
| | - Michael Weineck
- Institute of Medical Physics, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany
| | - Robert Kob
- Institute for Biomedicine of Aging, Friedrich-Alexander University Erlangen-Nürnberg, Nuremberg, Germany
| | - Thomas Bertsch
- Institute of Clinical Chemistry, Laboratory Medicine and Transfusion Medicine, Nuremberg General Hospital, Paracelsus Medical University, Nuremberg, Germany
| | - Wolfgang Kemmler
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany
| | - Daniel Schoene
- Institute of Medical Physics, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany
- Institute of Exercise and Public Health, University of Leipzig, Leipzig, Germany
| |
Collapse
|
7
|
de Oliveira TM, Felício DC, Filho JE, Fonseca DS, Durigan JLQ, Malaguti C. Effects of whole-body electromyostimulation on health indicators of older people: Systematic review and meta-analysis of randomized trials. J Bodyw Mov Ther 2022; 31:134-145. [DOI: 10.1016/j.jbmt.2022.03.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 02/08/2022] [Accepted: 03/17/2022] [Indexed: 10/18/2022]
|
8
|
Park S, Min S, Park SH, Yoo J, Jee YS. Influence of Isometric Exercise Combined With Electromyostimulation on Inflammatory Cytokine Levels, Muscle Strength, and Knee Joint Function in Elderly Women With Early Knee Osteoarthritis. Front Physiol 2021; 12:688260. [PMID: 34326779 PMCID: PMC8313868 DOI: 10.3389/fphys.2021.688260] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 06/15/2021] [Indexed: 12/16/2022] Open
Abstract
Background and Objectives: Muscle strengthening exercise is suggested to beneficial for patients with knee osteoarthritis (OA) and electrical muscular stimulation is reported to be effective in improvement of muscle strength. This study examined whether isometric exercise combined with whole body-electromyostimulation (WB-EMS) can improve serum cytokine levels, muscle strength, and knee function in elderly women with early knee OA. Materials and Methods: This randomized controlled study included 75 participants assigned into three groups: the control group (CON), isometric exercise group (ISOM), and isometric exercise and electromyostimulation group (ISOM + EMS). The two exercise groups performed their respective programs for 8 weeks, 3 days a week, 30 min a day. The main exercises for both groups were performed continuously during the 20 min in an alternation of a 6-s contraction with a 4-s break. At pre- and post-intervention, anthropometric variables, muscle strength, Knee Injury and Osteoarthritis Outcome Score (KOOS), and blood sampling for biomarkers including interleukin-6, tumor necrosis factor-α, C-reactive protein, and resistin were performed. Results: All variables at pre-intervention showed no significant differences among the three groups. However, there were significant differences between groups for body composition, muscle strength, KOOS subscale scores, and biomarkers. ISOM + EMS group resulted in a significant reduction in body weight, fat mass, fat percentage, inflammatory cytokine levels, and increased muscle strength. An ISOM + EMS group had the best KOOS score among all groups. Conclusion: Isometric exercise combined with WB-EMS resulted in the best overall improvements in knee function and alleviating the pain and symptoms of patients with early knee OA. Further, reduced levels of inflammatory cytokines were observed. These non-pharmacologic, non-invasive interventions should be considered by healthcare specialists for elderly patients with early knee OA.
Collapse
Affiliation(s)
- Sunhee Park
- Research Institute of Sports and Industry Science, Hanseo University, Seosan, South Korea
| | - Sukyung Min
- Research Institute of Sports and Industry Science, Hanseo University, Seosan, South Korea
| | - Si-Hwa Park
- Research Institute of Sports and Industry Science, Hanseo University, Seosan, South Korea
| | - Jaehyun Yoo
- Department of Physical Education, Sahmyook University, Seoul, South Korea
| | - Yong-Seok Jee
- Research Institute of Sports and Industry Science, Hanseo University, Seosan, South Korea
| |
Collapse
|
9
|
Kemmler W, Shojaa M, Steele J, Berger J, Fröhlich M, Schoene D, von Stengel S, Kleinöder H, Kohl M. Efficacy of Whole-Body Electromyostimulation (WB-EMS) on Body Composition and Muscle Strength in Non-athletic Adults. A Systematic Review and Meta-Analysis. Front Physiol 2021; 12:640657. [PMID: 33716787 PMCID: PMC7952886 DOI: 10.3389/fphys.2021.640657] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Accepted: 01/19/2021] [Indexed: 12/12/2022] Open
Abstract
This systematic review and meta-analysis set out to determine the efficacy on whole-body electromyostimulation (WB-EMS) on body composition and strength parameters in non-athletic cohorts. A systematic review of the literature according to the PRISMA statement included (a) controlled trials, (b) WB-EMS trials with at least one exercise and one control group, (c) WB-EMS as primary physical intervention, (d) WB-EMS with at least six electrodes covering most muscle groups, (e) non-athletic cohorts. We searched eight electronic databases up to June 30, 2020, without language restrictions. Standardized mean differences (SMD) for muscle mass parameters, total body fat mass, maximum leg extension, and trunk extension strength were defined as outcome measures. In summary, 16 studies with 19 individual WB-EMS groups representing 897 participants were included. Studies vary considerably with respect to age, BMI, and physical conditions. Impulse protocols of the studies were roughly comparable, but training frequency (1-5 sessions/week) and intervention length (6-54 weeks) differed between the studies. SMD average was 1.23 (95%-CI: 0.71-1.76) for muscle mass, 0.98 (0.74-1.22) for maximum leg, and 1.08 (0.78-1.39) for maximum trunk extension strength changes (all p < 0.001). SMD for body fat changes (-0.40, [-0.98 to 0.17]), however, did not reach significance. I 2 and Q-statistics revealed substantial heterogeneity of muscle and fat mass changes between the trials. However, rank and regression tests did not indicate positive evidence for small-study bias and funnel plot asymmetries. This work provided further evidence for significant, large-sized effects of WB-EMS on muscle mass and strength parameters, but not on body fat mass. Clinical Trial Registration: ClinicalTrials.gov, PROSPERO; ID: CRD42020183059.
Collapse
Affiliation(s)
- Wolfgang Kemmler
- Institute of Medical Physics, University of Erlangen-Nürnberg, Erlangen, Germany
| | - Mahdieh Shojaa
- Institute of Medical Physics, University of Erlangen-Nürnberg, Erlangen, Germany
| | - James Steele
- Ukactive Research Institute, London, United Kingdom.,Faculty of Sport, Health, and Social Sciences, Solent University, Southampton, United Kingdom
| | - Joshua Berger
- Department of Sports Science, Technische Universität Kaiserslauter, Kaiserslautern, Germany
| | - Michael Fröhlich
- Department of Sports Science, Technische Universität Kaiserslauter, Kaiserslautern, Germany
| | - Daniel Schoene
- Institute of Medical Physics, University of Erlangen-Nürnberg, Erlangen, Germany
| | - Simon von Stengel
- Institute of Medical Physics, University of Erlangen-Nürnberg, Erlangen, Germany
| | | | - Matthias Kohl
- Faculty Medical and Life Sciences, University of Furtwangen, Villingen-Schwenningen, Germany
| |
Collapse
|
10
|
Kim K, Eun D, Jee YS. Higher Impulse Electromyostimulation Contributes to Psychological Satisfaction and Physical Development in Healthy Men. ACTA ACUST UNITED AC 2021; 57:medicina57030191. [PMID: 33668740 PMCID: PMC7996253 DOI: 10.3390/medicina57030191] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 02/18/2021] [Accepted: 02/19/2021] [Indexed: 12/02/2022]
Abstract
Background and Objectives: This study investigated the various impulse effects of whole-body electromyostimulation (WB-EMS) on psychophysiological responses and adaptations. Materials and Methods: The participants included fifty-four men between 20 and 27 years of age who practiced isometric exercises for 20 min, three days a week, for 12 weeks while wearing WB-EMS suits, which enabled the simultaneous activation of eight muscle groups with three types of impulse intensities. Participants were allocated to one of four groups: control group (CON), low-impulse-intensity group (LIG), mid-impulse-intensity group (MIG), and high-impulse-intensity group (HIG). Psychophysiological conditions were measured at week 0, week 4, week 8, and week 12. Results: Compared with the CON, (1) three psychological conditions in LIG, MIG, and HIG showed positive tendencies every four weeks, and the analysis of covariance (ANCOVA) test revealed that body image (p = 0.004), body shape (p = 0.007), and self-esteem (p = 0.001) were significantly different among the groups. (2) Body weight, fat mass, body mass index, and percent fat in the CON showed decreasing tendencies, whereas those in LIG, MIG, and HIG showed a noticeable decrease, which revealed that there were significant differences among the groups. Specifically, a higher impulse intensity resulted in a greater increase in muscle mass. (3) Although there was no interaction effect in the abdominal visceral fat area, there were significant interactions in the abdominal subcutaneous fat (ASF) and total fat (ATF) areas. Both the ASF and ATF in the CON showed decreasing tendencies, whereas those in other groups showed a noticeable decrease. The ANCOVA revealed that the ASF (p = 0.002) and ATF (p = 0.001) were significantly different among the groups. In particular, the higher the impulse intensity, the greater the decrease in abdominal fat. Conclusions: This study confirmed that high-impulse-intensity EMS can improve psychophysiological conditions. In other words, healthy young adults felt that the extent to which their body image, body shape, and self-esteem improved depended on how intense their EMS impulse intensities were. The results also showed that higher levels of impulse intensity led to improved physical conditions.
Collapse
|