1
|
Mycobiome Diversity of the Cave Church of Sts. Peter and Paul in Serbia-Risk Assessment Implication for the Conservation of Rare Cavern Habitat Housing a Peculiar Fresco Painting. J Fungi (Basel) 2022; 8:jof8121263. [PMID: 36547596 PMCID: PMC9782640 DOI: 10.3390/jof8121263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 11/23/2022] [Accepted: 11/23/2022] [Indexed: 12/03/2022] Open
Abstract
The mycobiome of the cave Church of Sts. Peter and Paul, housing the peculiar fresco painting of “The Bald-headed Jesus”, was analyzed via culture-dependent and -independent methods. Salt efflorescence, colored patinas, and biofilm, as well as biopitting, discolorations, and fruiting bodies of wood-decay fungi were observed on surfaces within the church. Microscopic analyses showed an abundance of fungal structures, i.e., conidiophores, conidia, chlamydospores, and ascospores. The estimated values of the contamination classified all surfaces as the “Danger zone”. A total of 24 fungi from 17 genera were determined as part of the culturable mycobiome, with a dominance of Ascomycota of genera Penicillium. Biodegradative profiles analyzed via plate assays demonstrated positive reactions for 16 isolates: most commonly acid production (8), followed by pigment production and ligninolytic activity (6), protein degradation (5), cellulolytic activity (3) and carbonate dissolution (2). Metabarcoding analysis showed a dominance of Ascomycota in all samples (79.9−99.7%), with high relative abundance documented for Hypoxylon fuscopurpureum on the iconostasis and unclassified Mycosphaerellaceae family within order Capnodiales on fresco and stone, as well as moderate relative abundance for unclassified Dothideomycetes, Botryolepraria lesdainii, Verrucaria sp. and Cladosporium sp. on stone walls. The used set of integrative methods pointed out species of genus Neodevriesia and H. fuscopurpureum as the main deteriogenic agents of fresco and iconostasis surfaces, respectively.
Collapse
|
2
|
Frasca F, Verticchio E, Merello P, Zarzo M, Grinde A, Fazio E, García-Diego FJ, Siani AM. A Statistical Approach for A-Posteriori Deployment of Microclimate Sensors in Museums: A Case Study. SENSORS 2022; 22:s22124547. [PMID: 35746334 PMCID: PMC9230798 DOI: 10.3390/s22124547] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 06/13/2022] [Accepted: 06/14/2022] [Indexed: 02/01/2023]
Abstract
The deployment of sensors is the first issue encountered when microclimate monitoring is planned in spaces devoted to the conservation of artworks. Sometimes, the first decision regarding the position of sensors may not be suitable for characterising the microclimate close to climate-sensitive artworks or should be revised in light of new circumstances. This paper fits into this context by proposing a rational approach for a posteriori deployment of microclimate sensors in museums where long-term temperature and relative humidity observations were available (here, the Rosenborg Castle, Copenhagen, Denmark). Different statistical tools such as box-and-whisker plots, principal component analysis (PCA) and cluster analysis (CA) were used to identify microclimate patterns, i.e., similarities of indoor air conditions among rooms. Box-and-whisker plots allowed us to clearly identify one microclimate pattern in two adjoining rooms located in the basement. Multivariate methods (PCA and CA) enabled us to identify further microclimate patterns by grouping not only adjoining rooms but also rooms located on different floors. Based on these outcomes, new configurations about the deployment of sensors were proposed aimed at avoiding redundant sensors and collecting microclimate observations in other sensitive locations of this museum.
Collapse
Affiliation(s)
- Francesca Frasca
- Department of Physics, Sapienza University of Rome, P.le A. Moro 5, 00185 Rome, Italy;
| | - Elena Verticchio
- Department of Earth Sciences, Sapienza University of Rome, P.le A. Moro 5, 00185 Rome, Italy;
| | - Paloma Merello
- Department of Accounting, University of Valencia, Av. dels Tarongers s/n, 46022 Valencia, Spain;
| | - Manuel Zarzo
- Department of Applied Statistics, Operations Research and Quality, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain;
| | - Andreas Grinde
- Royal Danish Collections, Øster Voldgade 4A, 1355 Copenhagen, Denmark;
| | - Eugenio Fazio
- Department of Fundamental and Applied Sciences for Engineering, Sapienza Università di Roma, Via A. Scarpa 16, 00161 Roma, Italy;
| | - Fernando-Juan García-Diego
- Department of Applied Physics (U.D. Industrial Engineering), Universitat Politècnica de València, 46022 Valencia, Spain;
| | - Anna Maria Siani
- Department of Physics, Sapienza University of Rome, P.le A. Moro 5, 00185 Rome, Italy;
- Correspondence: ; Tel.: +39-06-4991-3479
| |
Collapse
|
3
|
Mitigating Harmful Effects of Climate Warming on Ceiling Paintings by Ceiling Insulation: An Evaluation Using Timed IR Imaging and Numeric Modelling. SUSTAINABILITY 2021. [DOI: 10.3390/su14010308] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Due to climate change, ceiling paintings in many historic buildings are subjected to increasingly high short-term temperature change, resulting in high thermal tension caused by the construction assembly. This article focuses on the combined use of timed IR imaging and numeric modelling to evaluate insulation measures on the upper side of a ceiling to reduce thermal tensions in the painting layers, overheating in summer as well as cooling down in winter. As a model room, the southern splendour stair hall in the Burgtheater Vienna was chosen. Famous ceiling paintings created from 1886 to 1888 by Gustav Klimt and his brother Ernst Klimt can be found on this ceiling. The results show that timed IR imaging is an adequate tool to study the transient thermal behaviour of ceiling paintings which are not accessible to standard sensor measurements. Moreover, it could be shown that the presented measurement technique is well suited to validate a numeric model. The latter was applied to evaluate the potential insulation on the top of the ceiling. It was shown that cooling loads and energy loss in the room underneath can be reduced and most importantly the thermal stress in painting layers is reduced. The findings are relevant as, due to global warming, the current situation in many buildings is worsening. Considering the great intangible cultural value of many ceiling paintings, the application of the presented evaluation strategy for building physical boundaries on a ceiling with paintings seems to be appropriate.
Collapse
|
4
|
Zarzo M, Perles A, Mercado R, García-Diego FJ. Multivariate Characterization of Temperature Fluctuations in a Historical Building Using Energy-Efficient IoT Wireless Sensors. SENSORS (BASEL, SWITZERLAND) 2021; 21:7795. [PMID: 34883797 PMCID: PMC8659786 DOI: 10.3390/s21237795] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Revised: 11/17/2021] [Accepted: 11/20/2021] [Indexed: 11/17/2022]
Abstract
Adequate thermic conditions are required for the preventive conservation of artworks, but such optimum conditions cannot always be achieved in historical buildings such as ancient churches. In those cases, it is of interest to assess the potential risk of punctual changes in indoor environments that can be harmful to artworks. These conditions can be assessed by means of a microclimate monitoring system comprised of a set of energy-efficient wireless sensors connected to the cloud using IoT techniques. This approach was followed at the baroque church of Saint Thomas and Saint Philip Neri in Valencia (Spain). A set of 26 wireless nodes was installed, which recorded values of temperature and relative humidity every hour for a period of 7 months. Small differences of temperature were obtained among sensors, so that an efficient methodology based on principal component analysis (PCA) was applied for the characterization of similarities and dissimilarities between sensors. Daily ranges of temperatures were studied as well as mean trajectories, differences between days of the week, and changes in the correlation structure of daily median values over time. Results provide a framework for an efficient characterization of temperatures in heritage buildings based on a network of wireless sensors. Such a framework is useful to assess the potential risk of temperature fluctuations on the preventive conservation of historical buildings and artworks.
Collapse
Affiliation(s)
- Manuel Zarzo
- Department of Applied Statistics, Operations Research and Quality, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain;
| | - Angel Perles
- ITACA Institute, Universitat Politècnica de València, 46022 Valencia, Spain;
| | - Ricardo Mercado
- ITACA Institute, Universitat Politècnica de València, 46022 Valencia, Spain;
| | - Fernando-Juan García-Diego
- Department of Applied Physics (U.D. Industrial Engineering), Universitat Politècnica de València, 46022 Valencia, Spain;
| |
Collapse
|
5
|
Ramírez S, Zarzo M, Perles A, García-Diego FJ. Characterization of Temperature Gradients According to Height in a Baroque Church by Means of Wireless Sensors. SENSORS 2021; 21:s21206921. [PMID: 34696134 PMCID: PMC8540709 DOI: 10.3390/s21206921] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 10/05/2021] [Accepted: 10/14/2021] [Indexed: 11/30/2022]
Abstract
The baroque church of Saint Thomas and Saint Philip Neri (Valencia, Spain), which was built between 1727 and 1736, contains valuable paintings by renowned Spanish artists. Due to the considerable height of the central nave, the church can experience vertical temperature gradients. In order to investigate this issue, temperatures were recorded between August 2017 and February 2018 from a wireless monitoring system composed of 21 sensor nodes, which were located at different heights in the church from 2 to 13 m from the floor level. For characterizing the temperature at high, medium and low altitude heights, a novel methodology is proposed based on sparse Partial Least Squares regression (sPLS), Linear Discriminant Analysis (LDA), and the Holt-Winters method, among others, which were applied to a time series of temperature. This approach is helpful to discriminate temperature profiles according to sensor height. Once the vertical thermal gradients for each month were characterized, it was found that temperature reached the maximum correlation with sensor height in the period between August 10th and September 9th. Furthermore, the most important features from the time series that explain this correlation are the mean temperature and the mean of moving range. In the period mentioned, the vertical thermal gradient was estimated to be about 0.043 ∘C/m, which implies a difference of 0.47 ∘C on average between sensor nodes at 2 m from the floor with respect to the upper ones located at 13 m from the floor level. The gradient was estimated as the slope from a linear regression model using height and hourly mean temperature as the predictor and response, respectively. This gradient is consistent with similar reported studies. The fact that such gradient was only found in one month suggests that the mechanisms of dust deposition on walls involved in vertical thermal gradients are not important in this case regarding the preventive conservation of artworks. Furthermore, the methodology proposed here was useful to discriminate the time series at high, medium and low altitude levels. This approach can be useful when a set of sensors is installed for microclimate monitoring in churches, cathedrals, and other historical buildings, at different levels and positions.
Collapse
Affiliation(s)
- Sandra Ramírez
- Department of Applied Statistics, Operations Research and Quality, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain; (S.R.); (M.Z.)
- Department of Natural Sciences and Mathematics, Pontificia Universidad Javeriana Cali, Cali 760031, Colombia
| | - Manuel Zarzo
- Department of Applied Statistics, Operations Research and Quality, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain; (S.R.); (M.Z.)
| | - Angel Perles
- ITACA Institute, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain;
| | - Fernando-Juan García-Diego
- Department of Applied Physics (U.D. Industrial Engineering), Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain
- Correspondence: ; Tel.: +34-96-387-7000
| |
Collapse
|
6
|
A Sensing System Based on Public Cloud to Monitor Indoor Environment of Historic Buildings. SENSORS 2021; 21:s21165266. [PMID: 34450715 PMCID: PMC8398254 DOI: 10.3390/s21165266] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 07/25/2021] [Accepted: 07/30/2021] [Indexed: 11/16/2022]
Abstract
Monitoring the indoor environment of historic buildings helps to identify potential risks, provide guidelines for improving regular maintenance, and preserve cultural artifacts. However, most of the existing monitoring systems proposed for historic buildings are not for general digitization purposes that provide data for smart services employing, e.g., artificial intelligence with machine learning. In addition, considering that preserving historic buildings is a long-term process that demands preventive maintenance, a monitoring system requires stable and scalable storage and computing resources. In this paper, a digitalization framework is proposed for smart preservation of historic buildings. A sensing system following the architecture of this framework is implemented by integrating various advanced digitalization techniques, such as Internet of Things, Edge computing, and Cloud computing. The sensing system realizes remote data collection, enables viewing real-time and historical data, and provides the capability for performing real-time analysis to achieve preventive maintenance of historic buildings in future research. Field testing results show that the implemented sensing system has a 2% end-to-end loss rate for collecting data samples and the loss rate can be decreased to 0.3%. The low loss rate indicates that the proposed sensing system has high stability and meets the requirements for long-term monitoring of historic buildings.
Collapse
|
7
|
Multivariate Time Series Analysis of Temperatures in the Archaeological Museum of L'Almoina (Valencia, Spain). SENSORS 2021; 21:s21134377. [PMID: 34206737 PMCID: PMC8271729 DOI: 10.3390/s21134377] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 06/07/2021] [Accepted: 06/19/2021] [Indexed: 11/17/2022]
Abstract
An earlier study carried out in 2010 at the archaeological site of L’Almoina (Valencia, Spain) found marked daily fluctuations of temperature, especially in summer. Such pronounced gradient is due to the design of the museum, which includes a skylight as a ceiling, covering part of the remains in the museum. In this study, it was found that the thermal conditions are not homogeneous and vary at different points of the museum and along the year. According to the European Standard EN10829, it is necessary to define a plan for long-term monitoring, elaboration and study of the microclimatic data, in order to preserve the artifacts. With the aforementioned goal of extending the study and offering a tool to monitor the microclimate, a new statistical methodology is proposed. For this propose, during one year (October 2019–October 2020), a set of 27 data-loggers was installed, aimed at recording the temperature inside the museum. By applying principal component analysis and k-means, three different microclimates were established. In order to characterize the differences among the three zones, two statistical techniques were put forward. Firstly, Sparse Partial Least Squares Discriminant Analysis (sPLS-DA) was applied to a set of 671 variables extracted from the time series. The second approach consisted of using a random forest algorithm, based on the same functions and variables employed by the first methodology. Both approaches allowed the identification of the main variables that best explain the differences between zones. According to the results, it is possible to establish a representative subset of sensors recommended for the long-term monitoring of temperatures at the museum. The statistical approach proposed here is very effective for discriminant time series analysis and for explaining the differences in microclimate when a net of sensors is installed in historical buildings or museums.
Collapse
|
8
|
Ramírez S, Zarzo M, Perles A, García-Diego FJ. A Methodology for Discriminant Time Series Analysis Applied to Microclimate Monitoring of Fresco Paintings. SENSORS 2021; 21:s21020436. [PMID: 33435459 PMCID: PMC7827762 DOI: 10.3390/s21020436] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Revised: 12/23/2020] [Accepted: 12/31/2020] [Indexed: 11/16/2022]
Abstract
The famous Renaissance frescoes in Valencia’s Cathedral (Spain) have been kept under confined temperature and relative humidity (RH) conditions for about 300 years, until the removal of the baroque vault covering them in 2006. In the interest of longer-term preservation and in order to maintain these frescoes in good condition, a unique monitoring system was implemented to record both air temperature and RH. Sensors were installed at different points at the vault of the apse during the restoration process. The present study proposes a statistical methodology for analyzing a subset of RH data recorded by the sensors in 2008 and 2010. This methodology is based on fitting different functions and models to the time series, in order to classify the different sensors.The methodology proposed, computes classification variables and applies a discriminant technique to them. The classification variables correspond to estimates of model parameters of and features such as mean and maximum, among others. These features are computed using values of functions such as spectral density, sample autocorrelation (sample ACF), sample partial autocorrelation (sample PACF), and moving range (MR). The classification variables computed were structured as a matrix. Next, sparse partial least squares discriminant analysis (sPLS-DA) was applied in order to discriminate sensors according to their position in the vault. It was found that the classification of sensors derived from Seasonal ARIMA-TGARCH showed the best performance (i.e., lowest classification error rate). Based on these results, the methodology applied here could be useful for characterizing the differences in RH, measured at different positions in a historical building.
Collapse
Affiliation(s)
- Sandra Ramírez
- Department of Applied Statistics, Operations Research and Quality, Universitat Politècnica de València, Camino de Vera, s/n 46022 Valencia, Spain;
- Department of Natural Sciences and Mathematics, Pontificia Universidad Javeriana Cali, 760031 Cali, Colombia
| | - Manuel Zarzo
- Department of Applied Statistics, Operations Research and Quality, Universitat Politècnica de València, Camino de Vera, s/n 46022 Valencia, Spain;
- Correspondence: (M.Z.); (F.-J.G.-D.); Tel.: +34-96-387-4900 (M.Z.)
| | - Angel Perles
- ITACA Institute, Universitat Politècnica de València, Camino de Vera, s/n 46022 Valencia, Spain;
| | - Fernando-Juan García-Diego
- Department of Applied Physics (U.D. Agriculture Engineering), Universitat Politècnica de València, Camino de Vera, s/n 46022 Valencia, Spain
- Correspondence: (M.Z.); (F.-J.G.-D.); Tel.: +34-96-387-4900 (M.Z.)
| |
Collapse
|
9
|
Marcelli A, Sebastianelli M, Conte A, Lucci F, Della Ventura G. Micro-climatic investigation and particulate detection in indoor environments: the case of the historical museum of Bersaglieri in Rome. RENDICONTI LINCEI. SCIENZE FISICHE E NATURALI 2020. [DOI: 10.1007/s12210-020-00935-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
10
|
Costantini I, Veneranda M, Irazola M, Aramendia J, Castro K, Madariaga JM. The green grass was never green: How spectroscopic techniques should have assisted restoration works. Microchem J 2018. [DOI: 10.1016/j.microc.2018.01.010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
11
|
Merello P, García-Diego FJ, Beltrán P, Scatigno C. High Frequency Data Acquisition System for Modelling the Impact of Visitors on the Thermo-Hygrometric Conditions of Archaeological Sites: A Casa di Diana (Ostia Antica, Italy) Case Study. SENSORS 2018; 18:s18020348. [PMID: 29370142 PMCID: PMC5854964 DOI: 10.3390/s18020348] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Revised: 01/20/2018] [Accepted: 01/21/2018] [Indexed: 11/22/2022]
Abstract
The characterization of the microclimatic conditions is fundamental for the preventive conservation of archaeological sites. In this context, the identification of the factors that influence the thermo-hygrometric equilibrium is key to determine the causes of cultural heritage deterioration. In this work, a characterization of the thermo-hygrometric conditions of Casa di Diana (Ostia Antica, Italy) is carried out analyzing the data of temperature and relative humidity recorded by a system of sensors with high monitoring frequency. Sensors are installed in parallel, calibrated and synchronized with a microcontroller. A data set of 793,620 data, arranged in a matrix with 66,135 rows and 12 columns, was used. Furthermore, the influence of human impact (visitors) is evaluated through a multiple linear regression model and a logistic regression model. The visitors do not affect the environmental humidity as it is very high and constant all the year. The results show a significant influence of the visitors in the upset of the thermal balance. When a tourist guide takes place, the probability that the hourly temperature variation reaches values higher than its monthly average is 10.64 times higher than it remains equal or less to its monthly average. The analysis of the regression residuals shows the influence of outdoor climatic variables in the thermal balance, such as solar radiation or ventilation.
Collapse
Affiliation(s)
- Paloma Merello
- Department of Accounting, University of Valencia, Av. de los Naranjos s/n, 46071 Valencia, Spain.
| | - Fernando-Juan García-Diego
- Department of Applied Physics, Universitat Politècnica de València, Av. de los Naranjos s/n, 46022 Valencia, Spain.
| | - Pedro Beltrán
- Department of Applied Physics, Universitat Politècnica de València, Av. de los Naranjos s/n, 46022 Valencia, Spain.
| | - Claudia Scatigno
- Nanoscience & Nanotechnology & Innovative Instrumentation (NAST Centre), University of Rome "Tor Vergata", Via della Ricerca Scientifica 1, 00133 Rome, Italy.
| |
Collapse
|
12
|
Visco G, Plattner SH, Fortini P, Sammartino M. A multivariate approach for a comparison of big data matrices. Case study: thermo-hygrometric monitoring inside the Carcer Tullianum (Rome) in the absence and in the presence of visitors. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2017; 24:13990-14004. [PMID: 28374205 DOI: 10.1007/s11356-017-8751-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2016] [Accepted: 03/02/2017] [Indexed: 06/07/2023]
Abstract
In the last decades, the very fast improvement of the analytical instrumentation has led to the possibility of quickly and easily getting a lot of data; in turn, the need of advanced statistical methods suitable to extract the full information furnished by instruments has increased. Such kind of data treatments is particularly important in any case of continuous monitoring of one or more parameters, so the microclimate monitoring is a typical example for this application. Microclimate control is essential in the conservation of Cultural Heritage (CH), but decisions on optimal conservation parameters cannot base only on existing norms that do not take into account the environment's history. Often CH has survived for many centuries in conditions that must be considered risky but also a stable state (equilibrium) resulting from a long adaptation process during which a more or less heavy damage occurred to the materials. Any successive change of microclimate parameters has interrupted this equilibrium conditions and has induced further damage to material until a new equilibrium is reached; dimension and frequency of changes are proportional to the expected damage. This thermodynamic consideration provides the background for a CH conservation project based on microclimate control and highlights the importance of environmental monitoring for the identification of equilibrium parameters to be maintained. In 2010, we monitored the microclimate of an important historical building in Rome, the Mamertino Carcer, before its opening to visitors. One year later, we repeated the monitoring in the presence of visitors, and here, we present a careful choice of multivariate data treatments adopted for an enough, simple and immediate evaluation of the microclimatic changes; this allows an easier understanding also for persons with not too deep scientific background, such as Superintendents and, in turn, really useful information to provide suggestions for a conservation project. Results evidenced the expected loss of isolation of the site that occurred by opening to visitors; this led to wider excursions of both temperature and relative humidity and, in turn, to a worsening of the conservative conditions. Surely, a monitoring of particulate matter, correlated to air fluxes and, in turn, to microclimate, is of fundamental importance for the conservation of frescoes and will be object of one of our future diagnostic interventions in the site.
Collapse
Affiliation(s)
- Giovanni Visco
- Chemistry Department, La Sapienza University, p.le A. Moro 5, 00185, Rome, Italy
| | - Susanne H Plattner
- Chemistry Department, La Sapienza University, p.le A. Moro 5, 00185, Rome, Italy
| | - Patrizia Fortini
- Cultural Heritage Superintendence of Rome City Council, Pz. Lovatelli 35, 00185, Rome, Italy
| | - Mariapia Sammartino
- Chemistry Department, La Sapienza University, p.le A. Moro 5, 00185, Rome, Italy.
| |
Collapse
|
13
|
Li H, Zhang J, Sun J. A visual analytics approach for deterioration risk analysis of ancient frescoes. J Vis (Tokyo) 2016. [DOI: 10.1007/s12650-015-0327-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
14
|
Merello P, García-Diego FJ, Zarzo M. Diagnosis of abnormal patterns in multivariate microclimate monitoring: a case study of an open-air archaeological site in Pompeii (Italy). THE SCIENCE OF THE TOTAL ENVIRONMENT 2014; 488-489:14-25. [PMID: 24814033 DOI: 10.1016/j.scitotenv.2014.04.068] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2013] [Revised: 04/16/2014] [Accepted: 04/17/2014] [Indexed: 06/03/2023]
Abstract
Chemometrics has been applied successfully since the 1990s for the multivariate statistical control of industrial processes. A new area of interest for these tools is the microclimatic monitoring of cultural heritage. Sensors record climatic parameters over time and statistical data analysis is performed to obtain valuable information for preventive conservation. A case study of an open-air archaeological site is presented here. A set of 26 temperature and relative humidity data-loggers was installed in four rooms of Ariadne's house (Pompeii). If climatic values are recorded versus time at different positions, the resulting data structure is equivalent to records of physical parameters registered at several points of a continuous chemical process. However, there is an important difference in this case: continuous processes are controlled to reach a steady state, whilst open-air sites undergo tremendous fluctuations. Although data from continuous processes are usually column-centred prior to applying principal components analysis, it turned out that another pre-treatment (row-centred data) was more convenient for the interpretation of components and to identify abnormal patterns. The detection of typical trajectories was more straightforward by dividing the whole monitored period into several sub-periods, because the marked climatic fluctuations throughout the year affect the correlation structures. The proposed statistical methodology is of interest for the microclimatic monitoring of cultural heritage, particularly in the case of open-air or semi-confined archaeological sites.
Collapse
Affiliation(s)
- Paloma Merello
- Department of Applied Physics (UD Industrial Engineering), Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain; Valencian Institute for Conservation and Restoration of Cultural Heritage (IVC+R), C/Genaro Lahuerta 25-3°, 46010 Valencia, Spain.
| | - Fernando-Juan García-Diego
- Department of Applied Physics (UD Industrial Engineering), Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain; Center of Physical Technologies, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain.
| | - Manuel Zarzo
- Department of Applied Statistics, Operations Research and Quality, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain.
| |
Collapse
|
15
|
Fernández-Navajas Á, Merello P, Beltrán P, García-Diego FJ. Multivariate thermo-hygrometric characterisation of the archaeological site of Plaza de l'Almoina (Valencia, Spain) for preventive conservation. SENSORS 2013; 13:9729-46. [PMID: 23899937 PMCID: PMC3812577 DOI: 10.3390/s130809729] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2013] [Revised: 07/16/2013] [Accepted: 07/23/2013] [Indexed: 12/04/2022]
Abstract
Preventive conservation requires monitoring and control of the parameters involved in the deterioration process, mainly temperature and relative humidity. It is important to characterise an archaeological site prior to carrying out comparative studies in the future for preventive conservation, either by regular studies to verify whether the conditions are constant, or occasional ones when the boundary conditions are altered. There are numerous covered archaeological sites, but few preventive conservation works that give special attention to the type of cover installed. In particular, there is no background of microclimatic studies in sites that are in the ground and, as in the Plaza de l’Almoina (Valencia, Spain), are buried and partially covered by a transparent roof. A large effect of the transparent cover was found by the sensors located below this area, with substantial increases in temperature and a decrease in the relative humidity during the day. Surrounding zones also have values above the recommended temperature values. On the other hand, the influence of a buried water drainage line near the site is notable, causing an increase in relative humidity levels in the surrounding areas. Multivariate statistical analyses enabled us to characterise the microclimate of the archaeological site, allowing future testing to determine whether the conservation conditions have been altered.
Collapse
Affiliation(s)
- Ángel Fernández-Navajas
- Departamento de Física Aplicada (U.D. Industriales), Universitat Politècnica de València, Av. de los Naranjos s/n, Valencia 46022, Spain; E-Mails: (Á.F.-N.); (P.M.); (P.B.)
| | - Paloma Merello
- Departamento de Física Aplicada (U.D. Industriales), Universitat Politècnica de València, Av. de los Naranjos s/n, Valencia 46022, Spain; E-Mails: (Á.F.-N.); (P.M.); (P.B.)
- Instituto Valenciano de Conservación y Restauración de Bienes Culturales (IVC+R), Complejo Socio-Educativo de Penyeta Roja s/n, Castellón 12080, Spain
| | - Pedro Beltrán
- Departamento de Física Aplicada (U.D. Industriales), Universitat Politècnica de València, Av. de los Naranjos s/n, Valencia 46022, Spain; E-Mails: (Á.F.-N.); (P.M.); (P.B.)
| | - Fernando-Juan García-Diego
- Departamento de Física Aplicada (U.D. Industriales), Universitat Politècnica de València, Av. de los Naranjos s/n, Valencia 46022, Spain; E-Mails: (Á.F.-N.); (P.M.); (P.B.)
- Centro de Tecnologías Físicas, Unidad Asociada ICMM- CSIC/UPV, Universitat Politècnica de València, Av. de los Naranjos s/n, Valencia 46022, Spain
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +34-61-063-3671
| |
Collapse
|
16
|
Array of Hall Effect sensors for linear positioning of a magnet independently of its strength variation. a case study: monitoring milk yield during milking in goats. SENSORS 2013; 13:8000-12. [PMID: 23793020 PMCID: PMC3715257 DOI: 10.3390/s130608000] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2013] [Revised: 06/10/2013] [Accepted: 06/11/2013] [Indexed: 11/17/2022]
Abstract
In this study we propose an electronic system for linear positioning of a magnet independent of its modulus, which could vary because of aging, different fabrication process, etc. The system comprises a linear array of 24 Hall Effect sensors of proportional response. The data from all sensors are subject to a pretreatment (normalization) by row (position) making them independent on the temporary variation of its magnetic field strength. We analyze the particular case of the individual flow in milking of goats. The multiple regression analysis allowed us to calibrate the electronic system with a percentage of explanation R2 = 99.96%. In our case, the uncertainty in the linear position of the magnet is 0.51 mm that represents 0.019 L of goat milk. The test in farm compared the results obtained by direct reading of the volume with those obtained by the proposed electronic calibrated system, achieving a percentage of explanation of 99.05%.
Collapse
|
17
|
Evaluation of corrective measures implemented for the preventive conservation of fresco paintings in Ariadne's house (Pompeii, Italy). Chem Cent J 2013; 7:87. [PMID: 23683173 PMCID: PMC3672094 DOI: 10.1186/1752-153x-7-87] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2012] [Accepted: 05/13/2013] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND A microclimate monitoring study was conducted in 2008 aimed at assessing the conservation risks affecting the valuable wall paintings decorating Ariadne's House (Pompeii, Italy). It was found that thermohygrometric conditions were very unfavorable for the conservation of frescoes. As a result, it was decided to implement corrective measures, and the transparent polycarbonate sheets covering three rooms (one of them delimited by four walls and the others composed of three walls) were replaced by opaque roofs. In order to examine the effectiveness of this measure, the same monitoring system comprised by 26 thermohygrometric probes was installed again in summer 2010. Data recorded in 2008 and 2010 were compared. RESULTS Microclimate conditions were also monitored in a control room with the same roof in both years. The average temperature in this room was lower in 2010, and it was decided to consider a time frame of 18 summer days with the same mean temperature in both years. In the rooms with three walls, the statistical analysis revealed that the diurnal maximum temperature decreased about 3.5°C due to the roof change, and the minimum temperature increased 0.5°C. As a result, the daily thermohygrometric variations resulted less pronounced in 2010, with a reduction of approximately 4°C, which is favorable for the preservation of mural paintings. In the room with four walls, the daily fluctuations also decreased about 4°C. Based on the results, other alternative actions are discussed aimed at improving the conservation conditions of wall paintings. CONCLUSIONS The roof change has reduced the most unfavorable thermohygrometric conditions affecting the mural paintings, but additional actions should be adopted for a long term preservation of Pompeian frescoes.
Collapse
|
18
|
Software for storage and management of microclimatic data for preventive conservation of cultural heritage. SENSORS 2013; 13:2700-18. [PMID: 23447005 PMCID: PMC3658708 DOI: 10.3390/s130302700] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/06/2013] [Revised: 01/23/2013] [Accepted: 02/15/2013] [Indexed: 11/17/2022]
Abstract
Cultural Heritage preventive conservation requires the monitoring of the parameters involved in the process of deterioration of artworks. Thus, both long-term monitoring of the environmental parameters as well as further analysis of the recorded data are necessary. The long-term monitoring at frequencies higher than 1 data point/day generates large volumes of data that are difficult to store, manage and analyze. This paper presents software which uses a free open source database engine that allows managing and interacting with huge amounts of data from environmental monitoring of cultural heritage sites. It is of simple operation and offers multiple capabilities, such as detection of anomalous data, inquiries, graph plotting and mean trajectories. It is also possible to export the data to a spreadsheet for analyses with more advanced statistical methods (principal component analysis, ANOVA, linear regression, etc.). This paper also deals with a practical application developed for the Renaissance frescoes of the Cathedral of Valencia. The results suggest infiltration of rainwater in the vault and weekly relative humidity changes related with the religious service schedules.
Collapse
|
19
|
Merello P, García-Diego FJ, Zarzo M. Microclimate monitoring of Ariadne's house (Pompeii, Italy) for preventive conservation of fresco paintings. Chem Cent J 2012. [PMID: 23190798 PMCID: PMC3541997 DOI: 10.1186/1752-153x-6-145] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Background Ariadne’s house, located at the city center of ancient Pompeii, is of great archaeological value due to the fresco paintings decorating several rooms. In order to assess the risks for long-term conservation affecting the valuable mural paintings, 26 temperature data-loggers and 26 relative humidity data-loggers were located in four rooms of the house for the monitoring of ambient conditions. Results Data recorded during 372 days were analyzed by means of graphical descriptive methods and analysis of variance (ANOVA). Results revealed an effect of the roof type and number of walls of the room. Excessive temperatures were observed during the summer in rooms covered with transparent roofs, and corrective actions were taken. Moreover, higher humidity values were recorded by sensors on the floor level. Conclusions The present work provides guidelines about the type, number, calibration and position of thermohygrometric sensors recommended for the microclimate monitoring of mural paintings in outdoor or semi-confined environments.
Collapse
Affiliation(s)
- Paloma Merello
- Department of Applied Physics (UD Agriculture Engineering), Universitat Politècnica de València, Camino de Vera s/n, 46022, Valencia, Spain.
| | | | | |
Collapse
|
20
|
Hung SS, Chang CY, Hsu CJ, Chen SW. Analysis of building envelope insulation performance utilizing integrated temperature and humidity sensors. SENSORS 2012; 12:8987-9005. [PMID: 23012529 PMCID: PMC3444087 DOI: 10.3390/s120708987] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Revised: 06/12/2012] [Accepted: 06/25/2012] [Indexed: 11/16/2022]
Abstract
A major cause of high energy consumption for air conditioning in indoor spaces is the thermal storage characteristics of a building's envelope concrete material; therefore, the physiological signals (temperature and humidity) within concrete structures are an important reference for building energy management. The current approach to measuring temperature and humidity within concrete structures (i.e., thermocouples and fiber optics) is limited by problems of wiring requirements, discontinuous monitoring, and high costs. This study uses radio frequency integrated circuits (RFIC) combined with temperature and humidity sensors (T/H sensors) for the design of a smart temperature and humidity information material (STHIM) that automatically, regularly, and continuously converts temperature and humidity signals within concrete and transmits them by radio frequency (RF) to the Building Physiology Information System (BPIS). This provides a new approach to measurement that incorporates direct measurement, wireless communication, and real-time continuous monitoring to assist building designers and users in making energy management decisions and judgments.
Collapse
Affiliation(s)
- San-Shan Hung
- Department of Automatic Control Engineering, Feng Chia University, No. 100, Wenhwa Road, Seatwen, Taichung 40724, Taiwan; E-Mail:
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +886-4-245-172-50 (ext. 3934); Fax: +886-4-245-199-51
| | - Chih-Yuan Chang
- Department of Civil Engineering, Feng Chia University, No. 100, Wenhwa Road, Seatwen, Taichung 40724, Taiwan; E-Mails: (C.-Y.C.); (C.-J.H.)
| | - Cheng-Jui Hsu
- Department of Civil Engineering, Feng Chia University, No. 100, Wenhwa Road, Seatwen, Taichung 40724, Taiwan; E-Mails: (C.-Y.C.); (C.-J.H.)
| | - Shih-Wei Chen
- Department of Automatic Control Engineering, Feng Chia University, No. 100, Wenhwa Road, Seatwen, Taichung 40724, Taiwan; E-Mail:
| |
Collapse
|
21
|
Multisensor system for isotemporal measurements to assess indoor climatic conditions in poultry farms. SENSORS 2012; 12:5752-74. [PMID: 22778611 PMCID: PMC3386710 DOI: 10.3390/s120505752] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2012] [Revised: 04/16/2012] [Accepted: 04/22/2012] [Indexed: 11/17/2022]
Abstract
The rearing of poultry for meat production (broilers) is an agricultural food industry with high relevance to the economy and development of some countries. Periodic episodes of extreme climatic conditions during the summer season can cause high mortality among birds, resulting in economic losses. In this context, ventilation systems within poultry houses play a critical role to ensure appropriate indoor climatic conditions. The objective of this study was to develop a multisensor system to evaluate the design of the ventilation system in broiler houses. A measurement system equipped with three types of sensors: air velocity, temperature and differential pressure was designed and built. The system consisted in a laptop, a data acquisition card, a multiplexor module and a set of 24 air temperature, 24 air velocity and two differential pressure sensors. The system was able to acquire up to a maximum of 128 signals simultaneously at 5 second intervals. The multisensor system was calibrated under laboratory conditions and it was then tested in field tests. Field tests were conducted in a commercial broiler farm under four different pressure and ventilation scenarios in two sections within the building. The calibration curves obtained under laboratory conditions showed similar regression coefficients among temperature, air velocity and pressure sensors and a high goodness fit (R(2) = 0.99) with the reference. Under field test conditions, the multisensor system showed a high number of input signals from different locations with minimum internal delay in acquiring signals. The variation among air velocity sensors was not significant. The developed multisensor system was able to integrate calibrated sensors of temperature, air velocity and differential pressure and operated successfully under different conditions in a mechanically-ventilated broiler farm. This system can be used to obtain quasi-instantaneous fields of the air velocity and temperature, as well as differential pressure maps to assess the design and functioning of ventilation system and as a verification and validation (V&V) system of Computational Fluid Dynamics (CFD) simulations in poultry farms.
Collapse
|
22
|
Development of a low-cost airborne ultrasound sensor for the detection of brick joints behind a wall painting. SENSORS 2012; 12:1299-311. [PMID: 22438711 PMCID: PMC3304113 DOI: 10.3390/s120201299] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2011] [Revised: 01/11/2012] [Accepted: 01/21/2012] [Indexed: 11/30/2022]
Abstract
Non-destructive methods are of great interest for the analysis of cultural heritage. Among the different possible techniques, this paper presents a low cost prototype based on the emission and reception of airborne ultrasound without direct contact with the test specimen. We successfully performed a method test for the detection of brick joints under a XVth century Renaissance fresco of the Metropolitan Cathedral of the city of Valencia (Spain). Both laboratory and in situ results are in agreement. Using this prototype system, an early moisture detection system has been installed in the dome that supports the fresco. The result is encouraging and opens interesting prospects for future research.
Collapse
|