1
|
López L, Martínez LM, Caicedo JR, Fernández-Vega L, Cunci L. Measurement of Neuropeptide Y in Aptamer-Modified Planar Electrodes. Electrochim Acta 2024; 488:144243. [PMID: 38654828 PMCID: PMC11034791 DOI: 10.1016/j.electacta.2024.144243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
Electrochemical impedance spectroscopy (EIS) is a powerful technique for studying the interaction at electrode/solution interfaces. The adoption of EIS for obtaining analytical signals in biosensors based on aptamers is gaining popularity because of its advantageous characteristics for molecular recognition. Neuropeptide Y (NPY), the most abundant neuropeptide in the body, plays a crucial role with its stress-relieving properties. Quantitative measurement of NPY is imperative for understanding its role in these and other biological processes. Although aptamer-modified electrodes for NPY detection using EIS present a promising alternative, the correlation between the data obtained and the adsorption process on the electrodes is not fully understood. Various studies utilize the change in charge transfer resistance when employing an active redox label. In contrast, label-free measurement relies on changes in capacitance. To address these challenges, we focused on the interaction between aptamer-modified planar electrodes and their target, NPY. We proposed utilizing -ω*Zimag as the analytical signal, which facilitated the analysis of the adsorption process using an analogous Langmuir isotherm equation. This approach differs from implantable microelectrodes, which adhere to the Freundlich adsorption isotherm. Notably, our method obviates the need for a redox label and enables the detection of NPY at concentrations as low as 20 pg/mL. This methodology demonstrated exceptional selectivity, exhibiting a signal difference of over 20-to-1 against potential interfering molecules.
Collapse
Affiliation(s)
- Luis López
- Department of Chemistry, University of Puerto Rico – Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, Puerto Rico 00931, United States
| | - Lyza M. Martínez
- Department of Chemistry, Universidad Ana G. Méndez – Gurabo, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
| | - Jaileen R. Caicedo
- Department of Chemistry, University of Puerto Rico – Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, Puerto Rico 00931, United States
| | - Lauren Fernández-Vega
- Department of Chemistry, Universidad Ana G. Méndez – Gurabo, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
- Department of Chemistry, Universidad Ana G. Méndez – Cupey, 1399 Ave Ana G Mendez, Cupey, Puerto Rico 00925, United States
| | - Lisandro Cunci
- Department of Chemistry, University of Puerto Rico – Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, Puerto Rico 00931, United States
| |
Collapse
|
2
|
Joseph S, Rajpal S, Kar D, Devinder S, Pandey S, Mishra P, Joseph J. Guided mode resonance immunosensor for label-free detection of pathogenic bacteria Pseudomonas aeruginosa. Biosens Bioelectron 2023; 241:115695. [PMID: 37776624 DOI: 10.1016/j.bios.2023.115695] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 07/10/2023] [Accepted: 09/15/2023] [Indexed: 10/02/2023]
Abstract
Photonic biosensors are promising platforms for the rapid detection of pathogens with the potential to replace conventional diagnostics based on microbiological culturing methods. Intricately designed sensing elements with robust architectures can offer highly sensitive detection at minimal development cost enabling rapid adoption in low-resource settings. In this work, an optical detection scheme is developed by structuring guided mode resonance (GMR) on a highly stable, transparent silicon nitride (SiN) substrate and further biofunctionalized to identify a specific bacteria Pseudomonas aeruginosa. The resonance condition of the GMR chip is optimized to have relatively high bulk sensitivity with a good quality factor. The biofunctionalization aims at oriented immobilization of specific antibodies to allow maximum bacteria attachment and improved specificity. The sensitivity of the assays is evaluated for clinically relevant concentrations ranging from 102 to 108 CFU/mL. From the calibration curves, the sensitivity of the chip is extracted as 0.134nm/Log10 [concentration], and the detection modality possesses a favorably good limit of detection (LOD) 89 CFU/mL. The use of antibodies as a biorecognition element complemented with a good figure of merit of GMR sensing element allows selective bacteria identification compared to other non-specific pathogenic bacteria that are relevant for testing physiological samples. Our developed GMR biosensor is low-cost, easy to handle, and readily transformable into a portable handheld detection modality for remote usage.
Collapse
Affiliation(s)
- Shereena Joseph
- Department of Physics, Indian Institute of Technology Delhi, New Delhi, India
| | - Soumya Rajpal
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, New Delhi, India
| | - Debashree Kar
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, New Delhi, India
| | - Shital Devinder
- Centre for Sensors, Instruments and Cyber Physical System Engineering, Indian Institute of Technology Delhi, New Delhi, India
| | - Saurabh Pandey
- Department of Physics, Indian Institute of Technology Delhi, New Delhi, India
| | - Prashant Mishra
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, New Delhi, India
| | - Joby Joseph
- Department of Physics, Indian Institute of Technology Delhi, New Delhi, India; Optics and Photonics Centre, Indian Institute of Technology Delhi, New Delhi, India.
| |
Collapse
|
3
|
Taheri A, Shokooh-Saremi M. Generalized homogenization method for subwavelength periodic lattices. Opt Express 2022; 30:42712-42727. [PMID: 36366719 DOI: 10.1364/oe.473746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Accepted: 10/22/2022] [Indexed: 06/16/2023]
Abstract
Periodic photonic lattices based on Guided-Mode Resonance (GMR) enable the manipulation of the incident light, making them essential components in a plethora of optical elements including filters, sensors, lasers, and polarizers. The GMR is regarded as a resonance phenomenon in the resonant-subwavelength regime of periodic lattices. We present a method that homogenizes these periodic structures in the subwavelength regime and provides an appropriate analytical interpretation of the resonance effect. Here, we propose a technique based on utilizing the dispersion relation for homogenization, which can be applied to multi-part period lattices under oblique incidence. The effect of asymmetry and emergence of the odd/even modes, not considered in previous methods, will also be taken into account and discussed. As a result of this analytical procedure, resonance lines are obtained, which are useful in designing optical elements such as wideband/narrowband reflectors and polarizers.
Collapse
|
4
|
Uludağ İ, Sezgintürk MK. Ultrasensitive and Cost-Effective Detection of Neuropeptide-Y by a Disposable Immunosensor: A New Functionalization Route for Indium-Tin Oxide Surface. Biosensors (Basel) 2022; 12:925. [PMID: 36354435 PMCID: PMC9688368 DOI: 10.3390/bios12110925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 10/22/2022] [Accepted: 10/24/2022] [Indexed: 06/16/2023]
Abstract
Neuropeptide Y (NPY) is one of the most abundant neuropeptides in the human brain, and its levels in the blood change in neurodegenerative and neuroimmune disorders. This indicates that NPY may serve as a diagnostic and monitoring marker for associated disorders. In this paper, an electrochemical immunosensor was created to detect NPY biomarkers using a novel immobilization technique. The proposed biosensor system enables accurate, specific, cost-effective, and practical biomarker analysis. Indium tin oxide-coated polyethylene terephthalate (ITO-PET) sheets were treated with hexamethylene diisocyanate (HMDC) to covalently immobilize antibodies. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques were used to analyze each step of the biosensors. The proposed NPY biosensor has a broad linear detection range (0.01-100 pg mL-1), a low limit of detection (LOD) (0.02968 pg mL-1), and a low limit of quantification (LOQ) (0.0989 pg mL-1). Atomic force microscopy (AFM) was used to support in the optimization process, study the surface morphology, and visualize it. Studies of repeatability, reproducibility, storage, and Kramers-Kronig transformation were conducted during electrochemical characterization. After analytical experiments, the biosensor's responses to human serum samples were evaluated. According to the obtained data, the error margin is small, and the created biosensor offers a great deal of promise for the clinical measurement of NPY.
Collapse
|
5
|
Zhou J, Dong S, Wei Z, Zhang J, Deng X, Wang Z, Cheng X. Two-dimensional guided-mode resonance gratings with an etch-stop layer and high tolerance to fabrication errors. Opt Express 2022; 30:25907-25917. [PMID: 36237110 DOI: 10.1364/oe.464065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 06/19/2022] [Indexed: 06/16/2023]
Abstract
Guided-mode resonance (GMR) bandpass filters have many important applications. The tolerance of fabrication errors that easily cause the transmission wavelength to shift has been well studied for one-dimensional (1D) anisotropic GMR gratings. However, the tolerance of two-dimensional (2D) GMR gratings, especially for different design architectures, has rarely been explored, which prevents the achievement of a high-tolerance unpolarized design. Here, GMR filters with common 2D zero-contrast gratings (ZCGs) were first investigated to reveal their differences from 1D gratings in fabrication tolerance. We demonstrated that 2D ZCGs are highly sensitive to errors in the grating linewidth against the case of 1D gratings, and the linewidth orthogonal to a certain polarization direction has much more influence than that parallel to the polarization. By analyzing the electromagnetic fields, we found that there was an obvious field enhancement inside the gratings, which could have a strong effect on the modes in the waveguide layer through the field overlap. Therefore, we proposed the introduction of an etch-stop (ES) layer between the gratings and the waveguide-layer, which can effectively suppress the interaction between the gratings and modal evanescent fields, resulting in 4-fold increased tolerance to the errors in the grating linewidth. Finally, the proposed etch-stop ZCGs (ES-ZCGs) GMR filters were experimentally fabricated to verify the error robustness.
Collapse
|
6
|
Samudrala SC, Das S, Lee KJ, Abdallah MG, Wenner BR, Allen JW, Allen MS, Magnusson R, Vasilyev M. Silicon-nitride microring resonators for nonlinear optical and biosensing applications. Appl Opt 2021; 60:G132-G138. [PMID: 34613202 DOI: 10.1364/ao.427731] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 06/25/2021] [Indexed: 06/13/2023]
Abstract
We discuss the design, fabrication, and characterization of silicon-nitride microring resonators for nonlinear-photonic and biosensing device applications. The first part presents new theoretical and experimental results that overcome highly normal dispersion of silicon-nitride microresonators by adding a dispersive coupler. The latter parts review our work on highly efficient second-order nonlinear interaction in a hybrid silicon-nitride slot waveguide with nonlinear polymer cladding and silicon-nitride microring application as a biosensor for human stress indicator neuropeptide Y at the nanomolar level.
Collapse
|
7
|
Lee SG, Kim SH, Kee CS. Creation of Fano resonances and bound states in the continuum in metallic metasurface superlattices. Opt Express 2021; 29:21492-21501. [PMID: 34265935 DOI: 10.1364/oe.428602] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 06/15/2021] [Indexed: 06/13/2023]
Abstract
A perfect metal film with a periodic arrangement of cut-through slits, an anisotropic metallic metamaterial film, mimics a dielectric slab and supports guided electromagnetic waves in the direction perpendicular to the slits. Since the guided Bloch modes exist only below the light line, conventional metallic metamaterial films do not exhibit interesting leaky-wave effects, such as bound states in the continuum and Fano resonances. Here, we introduce metallic metasurface superlattices that include multiple slits in a period and demonstrate that the superlattices support the Fano resonances and bound states in the continuum. We show that the number of Fano resonances and bound states depend on the number of slits in a period of superlattices through rigorous finite element method simulations. Experimental results in microwave region also support the creation of Fano resonance and bound states in the continuum by the increment of the number of slits in a period of superlattices.
Collapse
|
8
|
López L, Hernández N, Reyes Morales J, Cruz J, Flores K, González-Amoretti J, Rivera V, Cunci L. Measurement of Neuropeptide Y Using Aptamer-Modified Microelectrodes by Electrochemical Impedance Spectroscopy. Anal Chem 2021; 93:973-980. [PMID: 33297678 PMCID: PMC7856015 DOI: 10.1021/acs.analchem.0c03719] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Aptamer-modified microelectrodes for Neuropeptide Y measurement by electrochemical impedance spectroscopy was described here. The advantages of using carbon fiber or platinum microelectrodes are because they are promising materials with high electrical conductivity, chemical stability, and high surface area that can be easily modified on their surface. The immobilization and biofouling were studied and compared using EIS. Moreover, the adsorption of NPY to the aptamer-modified microelectrodes was also demonstrated by EIS. Changes of -ω*Zimag, an impedance factor that gives information of the capacitance, is directly correlated with concentrations. A widely linear range was obtained from 10 to 1000 ng/mL of NPY. This method was able to detect NPY without performing a redox reaction by adsorption at the surface of the microelectrodes, with the specificity provided by aptamer functionalization of the microelectrode surface.
Collapse
Affiliation(s)
- Luis López
- Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
| | - Nerika Hernández
- Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
| | - Joshua Reyes Morales
- Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
| | - John Cruz
- Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
| | - Krystal Flores
- Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
| | - John González-Amoretti
- Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
| | - Vitmary Rivera
- Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
| | - Lisandro Cunci
- Department of Chemistry, Universidad Ana G. Méndez, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
| |
Collapse
|
9
|
Zhou Y, Guo Z, Zhou W, Li S, Liu Z, Zhao X, Wu X. High-Q guided mode resonance sensors based on shallow sub-wavelength grating structures. Nanotechnology 2020; 31:325501. [PMID: 32330903 DOI: 10.1088/1361-6528/ab8cf0] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
We present a systematic investigation on the enhancement of the quality (Q) factors for guided-mode resonance (GMR) sensors with shallow subwavelength grating structures. By introducing the coupled-mode model, a theoretical high-Q factor can be achieved by choosing the proper geometric structure. Based on this method, a GMR sensor with a Q factor up to 8000, which is an order of magnitude larger than those of typical GMR sensors with Q factors within 100 ∼ 300, was demonstrated experimentally. Besides, the approached GMR sensor achieved a bulk sensitivity of 135 nm RIU-1 with a high signal to noise ratio, which supports a detection limit of 1 ng ml-1 for bovine serum albumin detection. This high performance GMR sensor paves the way towards high-throughput industrial mass production, and shows great potential for other applications, such as optical filters, spectrometer, and bio-imaging.
Collapse
Affiliation(s)
- Yi Zhou
- Key Laboratory of Micro and Nano Photonic Structures (Ministry of Education), Department of Optical Science and Engineering, Shanghai Engineering Research Center of Ultra Precision Optical Manufacturing, Fudan University, Shanghai 200433, People's Republic of China
| | | | | | | | | | | | | |
Collapse
|