1
|
Argüelles-Arias F, Donat E, Fernández-Urien I, Alberca F, Argüelles-Martín F, Martínez MJ, Molina M, Varea V, Herrerías-Gutiérrez JM, Ribes-Koninckx C. Guideline for wireless capsule endoscopy in children and adolescents: A consensus document by the SEGHNP (Spanish Society for Pediatric Gastroenterology, Hepatology, and Nutrition) and the SEPD (Spanish Society for Digestive Diseases). REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS 2017; 107:714-31. [PMID: 26671584 DOI: 10.17235/reed.2015.3921/2015] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
INTRODUCTION Capsule Endoscopy (CE) in children has limitations based mainly on age. The objective of this consensus was reviewing the scientific evidence. MATERIAL AND METHODS Some experts from the Spanish Society of Gastroenterology (SEPD) and Spanish Society for Pediatric Gastroenterology, Hepatology, and Nutrition (SEGHNP) were invited to answer different issues about CE in children. These sections were: a) Indications, contraindications and limitations; b) efficacy of CE in different clinical scenarios; c) CE performance; d) CE-related complications; e) Patency Capsule; and f) colon capsule endoscopy. They reviewed relevant questions on each topic. RESULTS The main indication is Crohn's disease (CD). There is no contraindication for the age and in the event that the patient not to swallow it, it should be administered under deep sedation with endoscopy and specific device. The CE is useful in CD, for the management of OGIB in children and in Peutz-Jeghers syndrome (in this indication has the most effectiveness). The main complication is retention, which should be specially taken into account in cases of CD already diagnosed with malnutrition. A preparation regimen based on a low volume of polyethylene glycol (PEG) the day before plus simethicone on the same day is the best one in terms of cleanliness although does not improve the results of the CE procedure. CONCLUSIONS CE is safe and useful in children. Indications are similar to those of adults, the main one is CD to establish both a diagnosis and disease extension. Moreover, only few limitations are detected in children.
Collapse
Affiliation(s)
| | | | | | - Fernando Alberca
- DIGESTIVO/ENDOSCOPIAS, Hospital Universitario Virgen de la Arrixaca. Murcia, España
| | | | | | | | | | | | | |
Collapse
|
2
|
Ciuti G, Tognarelli S, Verbeni A, Menciassi A, Dario P. Intraoperative bowel cleansing tool in active locomotion capsule endoscopy. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:4843-6. [PMID: 24110819 DOI: 10.1109/embc.2013.6610632] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Capsule endoscopy (CE) can be considered an example of "disruptive technology" since it represents a bright alternative to traditional diagnostic methodologies. If compared with traditional endoscopy, bowel cleansing procedure in CE becomes of greater importance, due to the impossibility to intraoperatively operate on unclean gastrointestinal tract areas. Considering the promising results and benefits obtained in the field of CE for gastrointestinal diagnosis and intervention, the authors approached the bowel cleansing issue with the final aim to propose an innovative and easy-to-use intraoperative cleansing system to be applied to an active locomotion softly-tethered capsule device, already developed by the authors. The system, that has to be intended as an additional tool for intraoperatively cleansing procedure of the colonic tract, is composed by a flexible tube with a metallic deflector attached to the distal end; it can be headed to the target area through the capsule operating channel. Performances of the colonoscopic capsule and intraoperative cleansing capabilities were successfully confirmed both in an in-vitro and ex-vivo experimental session. The innovative intraoperative cleansing system demonstrated promising results in terms of water injection, colonic wall cleansing procedure and subsequent water suction, thus guaranteeing to reduce the risk of inadequate visualization of the mucosa in endoscopic procedures.
Collapse
|
3
|
Palimaka S, Blackhouse G, Goeree R. Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Economic Analysis. ONTARIO HEALTH TECHNOLOGY ASSESSMENT SERIES 2015; 15:1-43. [PMID: 26366240 PMCID: PMC4561761] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
BACKGROUND Colorectal cancer is a leading cause of mortality and morbidity in Ontario. Most cases of colorectal cancer are preventable through early diagnosis and the removal of precancerous polyps. Colon capsule endoscopy is a non-invasive test for detecting colorectal polyps. OBJECTIVES The objectives of this analysis were to evaluate the cost-effectiveness and the impact on the Ontario health budget of implementing colon capsule endoscopy for detecting advanced colorectal polyps among adult patients who have been referred for computed tomographic (CT) colonography. METHODS We performed an original cost-effectiveness analysis to assess the additional cost of CT colonography and colon capsule endoscopy resulting from misdiagnoses. We generated diagnostic accuracy data from a clinical evidence-based analysis (reported separately), and we developed a deterministic Markov model to estimate the additional long-term costs and life-years lost due to false-negative results. We then also performed a budget impact analysis using data from Ontario administrative sources. One-year costs were estimated for CT colonography and colon capsule endoscopy (replacing all CT colonography procedures, and replacing only those CT colonography procedures in patients with an incomplete colonoscopy within the previous year). We conducted this analysis from the payer perspective. RESULTS Using the point estimates of diagnostic accuracy from the head-to-head study between colon capsule endoscopy and CT colonography, we found the additional cost of false-positive results for colon capsule endoscopy to be $0.41 per patient, while additional false-negatives for the CT colonography arm generated an added cost of $116 per patient, with 0.0096 life-years lost per patient due to cancer. This results in an additional cost of $26,750 per life-year gained for colon capsule endoscopy compared with CT colonography. The total 1-year cost to replace all CT colonography procedures with colon capsule endoscopy in Ontario is about $2.72 million; replacing only those CT colonography procedures in patients with an incomplete colonoscopy in the previous year would cost about $740,600 in the first year. LIMITATIONS The difference in accuracy between colon capsule endoscopy and CT colonography was not statistically significant for the detection of advanced adenomas (≥ 10 mm in diameter), according to the head-to-head clinical study from which the diagnostic accuracy was taken. This leads to uncertainty in the economic analysis, with results highly sensitive to changes in diagnostic accuracy. CONCLUSIONS The cost-effectiveness of colon capsule endoscopy for use in patients referred for CT colonography is $26,750 per life-year, assuming an increased sensitivity of colon capsule endoscopy. Replacement of CT colonography with colon capsule endoscopy is associated with moderate costs to the health care system.
Collapse
Affiliation(s)
- Stefan Palimaka
- Programs for Assessment of Technology in Health (PATH) Research Institute, St. Joseph's Healthcare, Hamilton, ON, Canada
| | - Gord Blackhouse
- Programs for Assessment of Technology in Health (PATH) Research Institute, St. Joseph's Healthcare, Hamilton, ON, Canada ; Department of Clinical Epidemiology and Biostatistics, Faculty of Health Sciences, McMaster University, Hamilton, ON, Canada
| | - Ron Goeree
- Programs for Assessment of Technology in Health (PATH) Research Institute, St. Joseph's Healthcare, Hamilton, ON, Canada ; Department of Clinical Epidemiology and Biostatistics, Faculty of Health Sciences, McMaster University, Hamilton, ON, Canada
| |
Collapse
|
4
|
Romero-Vázquez J, Argüelles-Arias F, García-Montes JM, Caunedo-Álvarez &A, Pellicer-Bautista FJ, Herrerías-Gutiérrez JM. Capsule endoscopy in patients refusing conventional endoscopy. World J Gastroenterol 2014; 20:7424-7433. [PMID: 24966612 PMCID: PMC4064087 DOI: 10.3748/wjg.v20.i23.7424] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2013] [Revised: 01/20/2014] [Accepted: 03/13/2014] [Indexed: 02/06/2023] Open
Abstract
Capsule endoscopy is nowadays the diagnostic technique of choice in the study of small bowel pathologies, allowing the non-invasive study of the entire mucosa. This has led, together with new technical advances, to the creation of two new models (PillCam ESO and PillCam Colon) for the study of esophageal and colonic diseases. These two new capsules offer an interesting alternative to conventional endoscopy in the study of the upper and lower digestive tracts, because traditional endoscopy is often unpleasant and uncomfortable for the patient, can be painful, often requires moderate or deep sedation and is not without complications (hemorrhage, perforation, etc.). PillCam Colon is particularly important for its usefulness in the diagnosis of colonic polyps, and is a potentially useful tool in cases of incomplete colonoscopy or in colorectal cancer screening, even more when most patients are reluctant to undergo screening programs due to the said disadvantages of conventional colonoscopy. This article discusses the advantages of capsule endoscopy over conventional endoscopy, its current application possibilities and indications in routine clinical practice. In the various sections of the work, we assess the application of endoscopic capsule in different sections of the digestive tract (esophagus, stomach, and colon) and finally the potential role of panendoscopy with PillCam Colon.
Collapse
|
5
|
Abstract
Colorectal cancer is the second leading cause of mortality in men and women in the United States. While there is a definite advantage regarding the use of colonoscopies in screening, there is still a lack of widespread acceptance of colonoscopy use in the general public. This is evident by the fact that up to 75% of patients diagnosed with colorectal cancer present with locally advanced disease. In order to make colonoscopy and in turn colorectal cancer screening a patient friendly and a comfortable test some changes in tool are necessary. The conventional colonoscope has not changed much since its development. There are several new advances in colorectal screening practices. One of the most promising new advances is the advent of robotic endoscopic techniques.
Collapse
Affiliation(s)
- Dan Cater
- Department of Surgery, College of Human Medicine, Michigan State University, Lansing, MI 48912, USA
| | - Arpita Vyas
- Department of Pediatrics, Michigan State University, Lansing, MI 48912, USA
| | - Dinesh Vyas
- Department of Surgery, College of Human Medicine, Michigan State University, Lansing, MI 48912, USA
| |
Collapse
|
6
|
Valdastri P, Ciuti G, Verbeni A, Menciassi A, Dario P, Arezzo A, Morino M. Magnetic air capsule robotic system: proof of concept of a novel approach for painless colonoscopy. Surg Endosc 2011; 26:1238-46. [PMID: 22179445 DOI: 10.1007/s00464-011-2054-x] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2011] [Accepted: 10/27/2011] [Indexed: 12/11/2022]
Abstract
BACKGROUND Despite being considered the most effective method for colorectal cancer diagnosis, colonoscopy take-up as a mass-screening procedure is limited mainly due to invasiveness, patient discomfort, fear of pain, and the need for sedation. In an effort to mitigate some of the disadvantages associated with colonoscopy, this work provides a preliminary assessment of a novel endoscopic device consisting in a softly tethered capsule for painless colonoscopy under robotic magnetic steering. METHODS The proposed platform consists of the endoscopic device, a robotic unit, and a control box. In contrast to the traditional insertion method (i.e., pushing from behind), a "front-wheel" propulsion approach is proposed. A compliant tether connecting the device to an external box is used to provide insufflation, passing a flexible operative tool, enabling lens cleaning, and operating the vision module. To assess the diagnostic and treatment ability of the platform, 12 users were asked to find and remove artificially implanted beads as polyp surrogates in an ex vivo model. In vivo testing consisted of a qualitative study of the platform in pigs, focusing on active locomotion, diagnostic and therapeutic capabilities, safety, and usability. RESULTS The mean percentage of beads identified by each user during ex vivo trials was 85 ± 11%. All the identified beads were removed successfully using the polypectomy loop. The mean completion time for accomplishing the entire procedure was 678 ± 179 s. No immediate mucosal damage, acute complications such as perforation, or delayed adverse consequences were observed following application of the proposed method in vivo. CONCLUSIONS Use of the proposed platform in ex vivo and preliminary animal studies indicates that it is safe and operates effectively in a manner similar to a standard colonoscope. These studies served to demonstrate the platform's added advantages of reduced size, front-wheel drive strategy, and robotic control over locomotion and orientation.
Collapse
Affiliation(s)
- P Valdastri
- STORM Lab, Mechanical Engineering Department, Vanderbilt University, 2301 Vanderbilt Place PMB 351592, Nashville, TN 37235-1592, USA.
| | | | | | | | | | | | | |
Collapse
|
7
|
Filip D, Yadid-Pecht O, Andrews CN, Mintchev MP. Self-stabilizing colonic capsule endoscopy: pilot study of acute canine models. IEEE TRANSACTIONS ON MEDICAL IMAGING 2011; 30:2115-2125. [PMID: 21803680 DOI: 10.1109/tmi.2011.2163165] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Video capsule endoscopy (VCE) is a noninvasive method for examining the gastrointestinal tract which has been successful in small intestine studies. Recently, VCE has been attempted in the colon. However, the capsule often tumbles in the wider colonic lumen, resulting in missed regions. Self-stabilizing VCE is a novel method to visualize the colon without tumbling. The aim of the present study was to comparatively quantify the effect of stabilization of a commercially available nonmodified capsule endoscope (CE) MiroCam and its modified self-stabilizing version in acute canine experiments. Two customized MiroCam CEs were reduced in volume at the nonimaging back-end to allow the attachment of a self-expanding, biocompatible stabilizing device. Four mongrel dogs underwent laparotomy and exteriorization of a 15-cm segment of the proximal descending colon. A single CE, either self-stabilizing or nonmodified was inserted through an incision into the lumen of the colon followed by pharmacologically induced colonic peristalsis. The inserted capsule was propelled distally through the colon and expelled naturally through the anus. Novel signal processing method was developed to quantify the video stabilization based on camera tracking a predetermined target point (locale). The average locale trajectory, the average radius movement of the locale, and the maximum rate of change of the locale for sequential images were significantly lower for the stabilized capsules compared to the nonstabilized ones . The feasibility of self-stabilized capsule endoscopy has been demonstrated in acute canine experiments.
Collapse
Affiliation(s)
- Dobromir Filip
- Department of Electrical and Computer Engineering, University of Calgary, Calgary, AB T2N 1N4 Canada
| | | | | | | |
Collapse
|
8
|
Tumino E, Sacco R, Bertini M, Bertoni M, Parisi G, Capria A. Endotics system vs colonoscopy for the detection of polyps. World J Gastroenterol 2010; 16:5452-6. [PMID: 21086563 PMCID: PMC2988238 DOI: 10.3748/wjg.v16.i43.5452] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2010] [Revised: 06/21/2010] [Accepted: 06/28/2010] [Indexed: 02/06/2023] Open
Abstract
AIM To compare the endotics system (ES), a set of new medical equipment for diagnostic colonoscopy, with video-colonoscopy in the detection of polyps. METHODS Patients with clinical or familial risk of colonic polyps/carcinomas were eligible for this study. After a standard colonic cleaning, detection of polyps by the ES and by video-colonoscopy was performed in each patient on the same day. In each single patient, the assessment of the presence of polyps was performed by two independent endoscopists, who were randomly assigned to evaluate, in a blind fashion, the presence of polyps either by ES or by standard colonoscopy. The frequency of successful procedures (i.e. reaching to the cecum), the time for endoscopy, and the need for sedation were recorded. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the ES were also calculated. RESULTS A total of 71 patients (40 men, mean age 51.9 ± 12.0 years) were enrolled. The cecum was reached in 81.6% of ES examinations and in 94.3% of colonoscopies (P = 0.03). The average time of endoscopy was 45.1 ± 18.5 and 23.7 ± 7.2 min for the ES and traditional colonoscopy, respectively (P < 0.0001). No patient required sedation during ES examination, compared with 19.7% of patients undergoing colonoscopy (P < 0.0001). The sensitivity and specificity of ES for detecting polyps were 93.3% (95% CI: 68-98) and 100% (95% CI: 76.8-100), respectively. PPV was 100% (95% CI: 76.8-100) and NPV was 97.7% (95% CI: 88-99.9). CONCLUSION The ES allows the visualization of the entire colonic mucosa in most patients, with good sensitivity/specificity for the detection of lesions and without requiring sedation.
Collapse
|
9
|
Jenkinson F, Steele RJC. Colorectal cancer screening - methodology. Surgeon 2010; 8:164-71. [PMID: 20400027 DOI: 10.1016/j.surge.2009.10.015] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2009] [Accepted: 10/22/2009] [Indexed: 12/27/2022]
Abstract
Colorectal cancer (CRC) is a major problem worldwide with the highest incidence being found in developed countries, and is the 3rd most common cancer in Scotland. Patients do not generally have symptoms related to CRC until late in the disease process, so there has been much interest in developing screening programmes to detect CRC early. Most commonly, screening involves the identification of occult blood in stool samples. Alternatives include flexible sigmoidoscopy, colonoscopy, radiological investigation and the identification of DNA mutations or proteins in stool. Candidate markers for mutation identification are K-ras, BRAF, p53 and APC which may be used alone or in combination to identify those with colorectal cancer.
Collapse
Affiliation(s)
- F Jenkinson
- Department of Surgery and Oncology, Ninewells Hospital and Medical School, University of Dundee, Scotland DD1 9SY, UK.
| | | |
Collapse
|
10
|
Koulaouzidis A, Douglas S. Capsule endoscopy in clinical practice: concise up-to-date overview. Clin Exp Gastroenterol 2009; 2:111-6. [PMID: 21694834 PMCID: PMC3108640 DOI: 10.2147/ceg.s4758] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2009] [Indexed: 12/22/2022] Open
Abstract
Until recently, the small bowel was considered a ‘no man’s land’ as the imaging modalities available for its investigation were laborious, invasive, costly, or involve significant radiation exposure. Wireless capsule endoscopy (WCE) has changed the field dramatically, over the last eight years. The established indications for small bowel WCE are obscure gastrointestinal bleed/anemia, Crohn’s disease, hereditary polyposis syndromes, and to a lesser extent, evaluation of side effects of nonsteroidal anti-inflammatory medications and coeliac disease. We herein present an overview of the capsule examination, which seems to be a quickly improving area.
Collapse
|
11
|
Abstract
Capsule endoscopy (CE) is a simple, safe, non-invasive, reliable technique, well accepted and tolerated by the patients, which allows complete exploration of the small intestine. The advent of CE in 2000 has dramatically changed the diagnosis and management of many diseases of the small intestine, such as obscure gastrointestinal bleeding, Crohn's disease, small bowel tumors, polyposis syndromes, etc. CE has become the gold standard for the diagnosis of most diseases of the small bowel. Lately this technique has also been used for esophageal and colonic diseases.
Collapse
|
12
|
Is PillCam COLON capsule endoscopy ready for colorectal cancer screening? A prospective feasibility study in a community gastroenterology practice. Am J Gastroenterol 2009; 104:848-54. [PMID: 19240710 DOI: 10.1038/ajg.2008.163] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Colorectal cancer (CRC) screening with colonoscopy was introduced into the National Cancer Prevention Program in Germany in 2002. As compliance for screening is low (around 3% per year), colon capsule endoscopy (CCE) could be an alternative approach. In this study, feasibility and performance of CCE were evaluated in comparison with colonoscopy in ambulatory patients with special attention to a short colon transit time. METHODS CCE was prospectively tested in ambulatory patients enrolled for colonoscopy who presented for screening or with positive fecal occult blood test. Study subjects underwent colon preparation and ingested the capsule in the morning. Colonoscopy was performed after excretion of the capsule. Colonoscopy and CCE were performed by independent physicians who were blinded to the results. RESULTS In total, 38 patients were included. One patient was excluded because the capsule remained in the stomach during the entire period of examination. Another patient had limited time and the procedure had to be stopped when the capsule was still in the transverse colon. We therefore report the results of 36 patients (30 men and 6 women; mean age 56 years, range 23-73 years) who successfully completed CCE and the conventional colonoscopy examination. The capsule was excreted within 6 h in 84% of the patients (median transit time 4.5 h). If oral sodium phosphate was excluded from the preparation, the colon transit time increased to a median of 8.25 h. In total, 7 of 11 small polyps (<6 mm) detected by colonoscopy were identified by CCE. One small polyp detected by CCE was not identified by colonoscopy. In this series, no large polyps were found. One CRC was detected by both methods. The mean rates of colon cleanliness (range from 1=excellent to 4=poor) in the cecum (2.1), transverse colon (1.6), and in the descending colon (1.5) were significantly better than in the rectosigmoid colon (2.6), and the overall mean rate during colonoscopy was significantly better than during CCE. No adverse effects occurred. CONCLUSIONS CCE appears to be a promising new modality for colonic evaluation and may increase compliance with CRC screening. To achieve a short colon transit time, sodium phosphate seems to be a necessary adjunct during preparation. The short transit time is a prerequisite to abandon the delay mode of the capsule. With an undelayed PillCam COLON capsule, a "pan-enteric" examination of the gastrointestinal tract would be possible. Further studies are needed to improve the cleanliness, especially in the rectum and to evaluate the method as a potential screening tool.
Collapse
|