1
|
Hajaj T, Lile IE, Veja I, Titihazan F, Rominu M, Negruțiu ML, Sinescu C, Novac AC, Talpos Niculescu S, Zaharia C. Influence of Pontic Length on the Structural Integrity of Zirconia Fixed Partial Dentures (FPDs). J Funct Biomater 2025; 16:116. [PMID: 40278224 PMCID: PMC12027926 DOI: 10.3390/jfb16040116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2025] [Revised: 03/23/2025] [Accepted: 03/24/2025] [Indexed: 04/26/2025] Open
Abstract
OBJECTIVE This study aims to evaluate the influence of pontic length and design on the fracture resistance of zirconia fixed dental prostheses (FDPs). By assessing different span lengths under controlled mechanical loading conditions, the research seeks to provide insights into optimizing the structural integrity of zirconia dental bridges. MATERIALS AND METHODS A total of 20 zirconia bridges were fabricated and tested in vitro. Ten bridges were designed to replace a single missing molar (tooth 46), with a pontic span of 11 mm, while the remaining ten were crafted for two missing teeth (35 and 36), featuring a longer pontic span of 17 mm. The zirconia frameworks were milled using the Wieland Zenotec® Select Hybrid system and cemented onto metal abutments with Voco Meron Plus QM resin-reinforced glass ionomer cement. The specimens were subjected to occlusal loading using a ZwickRoell ProLine Z005 testing machine at a crosshead speed of 1 mm/min until fracture occurred. RESULTS The mechanical testing revealed a significant correlation between pontic length and fracture resistance. The mean fracture resistance for three-unit bridges (single pontic) was 3703 N, whereas four-unit bridges (double pontic) exhibited a significantly lower resistance of 1713 N. These findings indicate that increased span length reduces the fracture resistance of zirconia restorations due to higher stress accumulation and reduced rigidity. CONCLUSIONS This study underscores the importance of pontic length and design in determining the fracture resistance of zirconia restorations. Shorter spans exhibit greater structural stability, reinforcing the need for careful treatment planning when designing multi-unit zirconia bridges. By optimizing bridge parameters, clinicians can improve clinical outcomes and extend the longevity of zirconia prostheses in restorative dentistry.
Collapse
Affiliation(s)
- Tareq Hajaj
- Department of Prostheses Technology and Dental Materials, Faculty of Dentistry, Victor Babes University of Medicine and Pharmacy, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania; (T.H.); (F.T.); (M.R.); (M.L.N.); (C.S.); (A.C.N.); (C.Z.)
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy of Timisoara, 9 Revolutiei 1989 Ave, 300070 Timisoara, Romania
| | - Ioana Elena Lile
- Department of Dental Medicine, Faculty of Dentistry, “Vasile Goldis” Western University of Arad, Str. Liviu Rebreanu 86, 310045 Arad, Romania;
| | - Ioana Veja
- Department of Dental Medicine, Faculty of Dentistry, “Vasile Goldis” Western University of Arad, Str. Liviu Rebreanu 86, 310045 Arad, Romania;
| | - Florina Titihazan
- Department of Prostheses Technology and Dental Materials, Faculty of Dentistry, Victor Babes University of Medicine and Pharmacy, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania; (T.H.); (F.T.); (M.R.); (M.L.N.); (C.S.); (A.C.N.); (C.Z.)
| | - Mihai Rominu
- Department of Prostheses Technology and Dental Materials, Faculty of Dentistry, Victor Babes University of Medicine and Pharmacy, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania; (T.H.); (F.T.); (M.R.); (M.L.N.); (C.S.); (A.C.N.); (C.Z.)
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy of Timisoara, 9 Revolutiei 1989 Ave, 300070 Timisoara, Romania
| | - Meda Lavinia Negruțiu
- Department of Prostheses Technology and Dental Materials, Faculty of Dentistry, Victor Babes University of Medicine and Pharmacy, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania; (T.H.); (F.T.); (M.R.); (M.L.N.); (C.S.); (A.C.N.); (C.Z.)
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy of Timisoara, 9 Revolutiei 1989 Ave, 300070 Timisoara, Romania
| | - Cosmin Sinescu
- Department of Prostheses Technology and Dental Materials, Faculty of Dentistry, Victor Babes University of Medicine and Pharmacy, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania; (T.H.); (F.T.); (M.R.); (M.L.N.); (C.S.); (A.C.N.); (C.Z.)
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy of Timisoara, 9 Revolutiei 1989 Ave, 300070 Timisoara, Romania
| | - Andreea Codruta Novac
- Department of Prostheses Technology and Dental Materials, Faculty of Dentistry, Victor Babes University of Medicine and Pharmacy, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania; (T.H.); (F.T.); (M.R.); (M.L.N.); (C.S.); (A.C.N.); (C.Z.)
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy of Timisoara, 9 Revolutiei 1989 Ave, 300070 Timisoara, Romania
| | - Serban Talpos Niculescu
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Victor Babes University of Medicine and Pharmacy, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania
| | - Cristian Zaharia
- Department of Prostheses Technology and Dental Materials, Faculty of Dentistry, Victor Babes University of Medicine and Pharmacy, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania; (T.H.); (F.T.); (M.R.); (M.L.N.); (C.S.); (A.C.N.); (C.Z.)
- Research Center in Dental Medicine Using Conventional and Alternative Technologies, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy of Timisoara, 9 Revolutiei 1989 Ave, 300070 Timisoara, Romania
| |
Collapse
|
2
|
Bakitian F. Effect of placement strategies and connector designs in CAD/CAM technology on fracture resistance of multilayered monolithic zirconia fixed dental prostheses: An in vitro study. Dent Mater J 2024; 43:693-700. [PMID: 39085143 DOI: 10.4012/dmj.2024-018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/02/2024]
Abstract
This study evaluated fracture resistance of monolithic fixed dental prostheses (FDPs) fabricated using different placement strategies of various connector designs in multilayered zirconia disc. Monolithic FDPs were placed in translucent and dentin layers of multilayered zirconia disc and fabricated with V-shaped and U-shaped connector designs gained by sharp and blunt millings. The FDPs were cemented on abutment models made of polymer material, underwent thermal cycles, and loaded to fracture using the universal testing machine. Fracture loads and modes were analyzed using two-way ANOVA, Tukey's post hoc test, and Fisher exact test (p≤0.05). The chosen placement strategy and connector designs gained by different milling procedures in computer-aided design/computer-aided manufacturing technology affect fracture resistance of monolithic FDPs made of multilayered zirconia materials. Placing the connector in translucent layer rather than dentin layer of multilayered zirconia disc and using sharp milling significantly reduces fracture resistance of monolithic multilayered zirconia FDPs.
Collapse
Affiliation(s)
- Fahad Bakitian
- Department of Restorative Dentistry, Faculty of Dental Medicine, Umm Al-Qura University
| |
Collapse
|
3
|
Bakitian F. Flexural Strength of Translucent Zirconia Materials Produced with Different Multilayer Technologies: An In Vitro Study. Int J Dent 2024; 2024:8410101. [PMID: 38571767 PMCID: PMC10990640 DOI: 10.1155/2024/8410101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 03/08/2024] [Accepted: 03/10/2024] [Indexed: 04/05/2024] Open
Abstract
Objective To evaluate the flexural strength of two translucent multilayered zirconia materials produced with different multilayer technologies. Methodology. Eighty bar-shaped zirconia specimens were prepared from two different multilayered zirconia materials (IPS e.max® ZirCAD Prime and KATANA™ Multilayered Zirconia HTML) and divided into eight groups (n = 10) based on the materials used and the individual layers of the disc for each material: Dentin Prime, Transition Prime, Translucent Prime, Multilayered Prime, Dentin HTML, Transition HTML, Translucent HTML, and Multilayered HTML. The bar-shaped zirconia specimens were cut to include all the layers from translucent to dentin In Multilayered Prime and Multilayered HTML groups. All specimens were fully sintered after cutting from multilayered zirconia discs and subjected to three-point flexural strength test using the universal testing machine. Results The specimens made of HTML zirconia material showed significantly (P < 0.001) higher flexural strength than those made of IPS e.max® ZirCAD Prime material, with no significant difference (P > 0.05) compared to the specimens in the Dentin Prime group. The Dentin Prime specimens had the highest flexural strength (743 ± 116 MPa) compared to those in the Translucent Prime (514 ± 120 MPa), Transition Prime (575 ± 102 MPa), and Multilayered Prime (531 ± 132 MPa) groups. The flexural strength of the specimens from the individual layers of HTML zirconia material was not significantly different (P > 0.05) among the Dentin HTML (763 ± 56 MPa), Translucent HTML (791 ± 106 MPa), Transition HTML (816 ± 85 MPa), and Multilayered HTML (793 ± 102 MPa) groups. Conclusion Multilayered zirconia materials produced with different yttria contents by layer have lower flexural strength than those produced with gradient shade technology and the same yttria content for each layer. Therefore, various factors such as the type of prostheses, nesting strategies of prostheses within the zirconia disc, and the desired aesthetical requirements should be considered when selecting the multilayered zirconia materials.
Collapse
Affiliation(s)
- Fahad Bakitian
- Department of Restorative Dentistry, Faculty of Dental Medicine, Umm Al-Qura University, Makkah, Saudi Arabia
| |
Collapse
|