1
|
Kasahara M, Shoji N. Visual Function After Schlemm's Canal-Based MIGS. J Clin Med 2025; 14:2531. [PMID: 40217980 PMCID: PMC11989462 DOI: 10.3390/jcm14072531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2025] [Revised: 03/21/2025] [Accepted: 04/02/2025] [Indexed: 04/14/2025] Open
Abstract
Filtration surgery is highly effective in lowering intraocular pressure; however, it is associated with a higher risk of severe complications. Visual dysfunction may persist in relatively uneventful cases because of induced astigmatism or worsening optical aberrations. Therefore, for early- to moderate-stage glaucoma, an increasing number of surgeons are prioritizing surgical safety and preserving postoperative visual function by opting for minimally invasive glaucoma surgery (MIGS). Among the various MIGS techniques, canal-opening surgery-targeting aqueous outflow through the Schlemm's canal (Schlemm's canal-based MIGS, CB-MIGS)-has gained increasing popularity. Unlike filtration surgery, CB-MIGS does not require creating an aqueous outflow pathway between the intraocular and extraocular spaces. Consequently, it is considered a minimally invasive procedure with a reduced risk of severe complications and is increasingly being chosen for suitable cases. Although this surgical technique has limitations in lowering intraocular pressure, it avoids the manipulation of the conjunctiva or sclera and is primarily performed through a small corneal incision. Therefore, a minimal impact on induced astigmatism or postoperative refractive changes is expected. However, few reviews comprehensively summarize postoperative changes in visual function. Therefore, this study reviews the literature on visual function after CB-MIGS, focusing on changes in best-corrected visual acuity (BCVA), refraction, astigmatism, and the effectiveness of visual field preservation to assess the extent of these postoperative changes. Hyphema is the primary cause of early postoperative vision loss and is often transient in cases in which other complications would have led to visual impairment. Severe complications that threaten vision are rare. Additionally, compared with filtration surgery, postoperative visual recovery tends to be faster, and the degree of induced astigmatism is comparable to that of standalone cataract surgery. When combined with cataract surgery, the refractive error is at the same level as that of cataract surgery alone. However, in some cases, mild hyperopic shifts may occur because of axial length shortening, depending on the extent of intraocular pressure reduction. This possibility has been highlighted in several studies. Regarding the effectiveness of slowing the progression of visual field defects, most studies have focused on short- to medium-term postoperative outcomes. Many of these studies have reported the sufficient suppression of progression rates. However, studies with large sample sizes and long-term prospective designs are limited. To establish more robust evidence, future research should focus on conducting larger-scale, long-term investigations.
Collapse
Affiliation(s)
- Masayuki Kasahara
- Department of Ophthalmology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara 252-0374, Kanagawa, Japan;
| | | |
Collapse
|
2
|
Guedes J, Amaral DC, de Oliveira Caneca K, Cassins Aguiar EH, de Oliveira LN, Mora-Paez DJ, Cyrino LG, Louzada RN, Moster MR, Myers JS, Schuman JS, Shukla AG, Shalaby WS. Kahook Dual Blade Goniotomy Versus iStent Implantation Combined With Phacoemulsification: A Systematic Review and Meta-Analysis. J Glaucoma 2025; 34:232-247. [PMID: 39641580 DOI: 10.1097/ijg.0000000000002522] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2024] [Accepted: 11/17/2024] [Indexed: 12/07/2024]
Abstract
PRCIS In this meta-analysis, Kahook dual blade (KDB) goniotomy achieved higher rates of surgical success compared with iStent/iStent inject implantation combined with phacoemulsification. KDB goniotomy demonstrated better intraocular pressure (IOP) reduction at month 6 compared with the stent group. OBJECTIVE To compare the outcomes of phacoemulsification combined with either KDB goniotomy (phaco-KDB) or trabecular microbypass stent (iStent and iStent inject) implantation (phaco-Stent). METHODS A literature search was performed on PubMed, Embase, Web of Science, and Cochrane Library from inception to April 2024. Randomized clinical trials and observational studies that compared KDB goniotomy to the first or second-generation iStent combined with phacoemulsification were included. The main outcome measures were surgical success, mean change in IOP and medication number, and complication rates. Mean differences (MDs) and pooled odds ratios were used to analyze continuous and binary outcomes, respectively. RESULTS Fourteen studies were included with a total of 1959 eyes (958 phaco-KDB, and 1000 phaco-Stent including 753 phaco-iStent and 207 phaco-iStent inject). The combined findings showed significantly higher rates of surgical success in the phaco-KDB group versus the phaco-Stent group (odds ratio: 0.68; 95% CI: 0.50 to 0.92; P = 0.01; I2 = 40%), and greater IOP reduction in the phaco-KDB group versus the phaco-Stent group at month 6 (MD: 1.13 mm Hg; 95% CI: 0.43 to 1.83; P = 0.002; I2 = 51%). By month 12, both groups demonstrated similar IOP reduction. Subgroup analysis at month 12 showed greater IOP reduction in the phaco-KDB group versus the phaco-iStent group (MD: 1.69 mm Hg; 95% CI: 0.44 to 2.95; P = 0.008; I2 = 74%). However, compared with the phaco-iStent inject group, there was no significant difference in IOP reduction (MD: -0.72 mm Hg; 95% CI: -3.69 to 2.24; P = 0.63; I2 = 64%). Medication reduction and the incidence of adverse events were comparable between groups. CONCLUSION KDB goniotomy may offer better surgical success compared with Stent implantation when used in combination with phacoemulsification. KDB goniotomy demonstrated better IOP reduction at month 12 compared with iStent. However, iStent inject showed a similar IOP reduction to KDB.
Collapse
Affiliation(s)
- Jaime Guedes
- Glaucoma Service, Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University
| | - Dillan Cunha Amaral
- Drexel University School of Biomedical Engineering, Science and Health Studies, Philadelphia, PA
| | | | | | | | - Denisse J Mora-Paez
- Glaucoma Service, Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University
| | | | - Ricardo Noguera Louzada
- Faculty of Medicine, Federal University of Rio de Janeiro, Rio de Janeiro, RJ
- University of São Paulo, São Paulo, SP, Brazil
| | - Marlene R Moster
- Glaucoma Service, Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University
| | - Jonathan S Myers
- Glaucoma Service, Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University
| | - Joel S Schuman
- Glaucoma Service, Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University
- University of São Paulo, São Paulo, SP, Brazil
| | | | - Wesam Shamseldin Shalaby
- Glaucoma Service, Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University
- Department of Ophthalmology, Tanta Medical School, Tanta University, Tanta, Gharbia, Egypt
| |
Collapse
|
3
|
Khoo PY, Tang SF, Lam C, Cheng TC, Din NM. One-Year comparative analysis between standalone iStent implantation versus combined iStent implantation with phacoemulsification. Eur J Ophthalmol 2025; 35:611-617. [PMID: 39109547 DOI: 10.1177/11206721241273678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2025]
Abstract
PURPOSE To evaluate the real-world efficacy and safety of iStent implanted standalone or combined with phacoemulsification in open-angle glaucoma (OAG) patients. METHODS This is a retrospective observational study of OAG patients who underwent standalone or combined iStent procedures were reviewed. Inclusion criteria included age over 18 years and open angle on gonioscopy. Exclusion criteria were prior incisional glaucoma surgeries, missing data, or follow-up shorter than 6 months. The primary outcome was surgical success between the two groups after one year. Secondary outcomes included differences in IOP reduction and medication use. RESULTS We included 48 eyes with primary (n = 44) and secondary OAG (n = 4). Nineteen eyes had standalone while 29 eyes had combined procedures. Kaplan-Meier analysis revealed overall surgical success in 31.3% of eyes after one year. Qualified success was higher in the combined group than the standalone group [62.5% (10 eyes) vs 27.3% (3 eyes), p = 0.239]. At 24 months, mean IOP reduced by 2.2 ± 2.5 mmHg vs 3.3 ± 2.9 mmHg, p = 0.333), and the number of medications reduced by 1.1 ± 1.2 vs 1.3 ± 0.1, p < 0.001) in the standalone and combined group, respectively. Stent occlusion occurred in two eyes. CONCLUSIONS While both standalone and combined iStent procedures provide safe IOP reduction throughout 12 months, there was no statistically significant difference in surgical success between them.
Collapse
Affiliation(s)
- Phong Yue Khoo
- Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Cheras, Kuala Lumpur, Malaysia
| | - Seng Fai Tang
- Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Cheras, Kuala Lumpur, Malaysia
- Optimax Eye Specialist Center, Taman Tun Dr Ismail, Kuala Lumpur, Malaysia
| | - Chenshen Lam
- Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Cheras, Kuala Lumpur, Malaysia
| | - Teck Chee Cheng
- Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Cheras, Kuala Lumpur, Malaysia
| | - Norshamsiah Md Din
- Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Cheras, Kuala Lumpur, Malaysia
| |
Collapse
|
4
|
Algorinees R, Almohizea A, Aldalgan H, Alobaida I, Schargel K, Aljohar S. Outcomes of iStent versus endocyclophotocoagulation (ECP) as adjunct to cataract surgery by phacoemulsification for glaucoma patients. Eur J Ophthalmol 2025; 35:206-213. [PMID: 38860310 DOI: 10.1177/11206721241261418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2024]
Abstract
PURPOSE To compare the efficacy and safety of iStent versus Endocyclophotocoagulation (ECP) as an adjunct to cataract surgery by Phacoemulsification for treating glaucoma patients in a tertiary eye center. METHODS Retrospective study of 67 eyes of 61 patients with glaucoma and cataract who underwent either phaco-ECP or phaco-iStent. Primary efficacy endpoint is the Intraocular pressure (IOP) reduction, while reduction of glaucoma medications is the secondary outcome. In addition to IOP and number of glaucoma medications; visual acuity, degree of disc cupping, safety profiles were all assessed at different intervals up to 12 months. RESULTS A total of 40 eyes underwent phaco-ECP, and 27 eyes underwent phaco-iStent. Both groups were associated with a significant reduction in the number of glaucoma medications; however phaco-iStent group achieved slightly lower IOP levels than the phaco-ECP group. Furthermore, iStent inject had better control of IOP at the last follow-up compared to first-generation stents. Moreover; 2 or more stents significantly reduced IOP than single stent (p = 0.009 vs. p = 0.618, respectively). Phaco-iStent achieved a better reduction in the number of glaucoma medications for primary open-angle glaucoma (p = 0.007) compared to pseudoexfoliation glaucoma patients (p = 0.084). Complications were seen in 12 eyes (18%), of which five eyes in phaco-ECP (7.4%) and 7 eyes in phaco-iStent (10.4%), majority were mild and treated conservatively. CONCLUSIONS Both groups had equal efficacy in reducing the IOP. However, phaco-iStent seems superior in reducing the number of glaucoma medications after 1 year of follow-up compared to phaco-ECP, particularly when 2 or more stents are used. Both groups showed an overall good safety profile.
Collapse
Affiliation(s)
- Rakan Algorinees
- Glaucoma Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
- Faculty of Ophthalmology, College of Medicine, University of Ha'il, Ha'il, Saudi Arabia
| | - Asma Almohizea
- Glaucoma Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
| | - Hind Aldalgan
- Faculty of Ophthalmology, College of Medicine, Imam Abdulrahman bin Faisal university, Al Khobar, Saudi Arabia
| | - Ibrahim Alobaida
- Glaucoma Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
| | - Konrad Schargel
- Glaucoma Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
| | - Seham Aljohar
- Epidemiology Section, Research Department, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
| |
Collapse
|
5
|
Oo HH, Hong ASY, Lim SY, Ang BCH. Angle-based minimally invasive glaucoma surgery in normal tension glaucoma: A systematic review and meta-analysis. Clin Exp Ophthalmol 2024; 52:740-760. [PMID: 38853535 DOI: 10.1111/ceo.14408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Accepted: 05/23/2024] [Indexed: 06/11/2024]
Abstract
BACKGROUND This systematic review and meta-analysis quantitatively examines the efficacy of angle-based minimally invasive glaucoma surgery (MIGS) in normal tension glaucoma (NTG). METHODS A literature search was performed on Medline, Embase, PubMed, CINAHL and Cochrane Library from inception until 20 December 2022. Pilot, cohort, observational studies and randomised controlled trials including at least 5 subjects undergoing angle-based MIGS (trabecular-bypass devices, excisional trabeculotomy, goniotomy and ab-interno canaloplasty) for NTG, with or without cataract surgery, were included. Meta-analysis of continuous outcome using the meta routine in R version 2022.12.0+353 was performed to determine mean intraocular pressure (IOP) and anti-glaucoma medication (AGM) reduction post-operatively. RESULTS Of the 846 studies initially identified, 15 studies with a pooled total of 367 eyes which underwent combined phacoemulsification and angle-based MIGS were included for final meta-analysis. Outcomes of the iStent were reported in 5 studies, iStent inject in 7 studies, Hydrus Microstent in 1 study, Kahook Dual Blade in 3 studies, and Trabectome in 2 studies. There was significant reduction in both IOP and AGM post-operatively at 6 months (2.44 mmHg, 95%CI: 1.83-3.06; 1.21 AGM, 95%CI: 0.99-1.44), 12 months (2.28 mmHg, 95%CI: 1.71-2.84; 1.18 AGM, 95%CI: 0.90-1.47), 24 months (2.10 mmHg, 95%CI: 1.51-2.68; 1.26 AGM, 95%CI: 0.85-1.68) and 36 months (2.43 mmHg, 95%CI: 1.71-3.15, 0.87 AGM, 95%CI: 0.21-1.53) (all p < 0.05). Subgroup analysis on combined phacoemulsification-iStent inject surgery demonstrated a reduction in both IOP (2.31 mmHg, 95%CI: 1.07-3.56, p < 0.001) and AGM (1.07 AGM, 95%CI: 0.86-1.29, p < 0.001) at 12 months post-operatively. CONCLUSIONS Angle-based MIGS combined with phacoemulsification effectively reduces IOP and AGM in NTG eyes for up to 36 months after surgery.
Collapse
Affiliation(s)
- Hnin Hnin Oo
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| | | | - Sheng Yang Lim
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| | - Bryan Chin Hou Ang
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
- Department of Ophthalmology, National Healthcare Group Eye Institute, Woodlands Health, Singapore, Singapore
- Department of Ophthalmology, Mayo Clinic, Jacksonville, Florida, USA
| |
Collapse
|
6
|
Dada T, Beri N, Mahalingam K, Sharma N. Functional assessment of trabecular bypass created by iStent inject using aqueous angiography. BMJ Case Rep 2024; 17:e258741. [PMID: 38531556 PMCID: PMC10966727 DOI: 10.1136/bcr-2023-258741] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/28/2024] Open
Affiliation(s)
- Tanuj Dada
- Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Nitika Beri
- Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Karthikeyan Mahalingam
- Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Namrata Sharma
- Ophthalmology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
7
|
Morita S, Sakanishi Y, Riyu I, Watanabe S, Ebihara N. Comparative evaluation of iStent versus iStent inject W combined with phacoemulsification in open angle glaucoma. PLoS One 2024; 19:e0297514. [PMID: 38315707 PMCID: PMC10843132 DOI: 10.1371/journal.pone.0297514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 12/29/2023] [Indexed: 02/07/2024] Open
Abstract
PURPOSE The study aimed to compare the 12-month post-operative outcomes of iStent and iStent inject W (inject W), and the factors associated with their success in open-angle glaucoma. METHODS This single-center, retrospective comparative case series evaluated the medical records of patients who underwent iStent (comprising 1 stent) or inject W (comprising 2 stents) implantation with cataract surgery for primary open-angle glaucoma and normal tension glaucoma between January 2019 and March 2022. The 12-month post-operative efficacy outcomes included intraocular pressure (IOP), glaucoma medications, and survival analysis of the probability of success. "Failure" was defined as any of the following conditions compared to baseline: 1) IOP elevation, 2) increased glaucoma medication, or 3) IOP decline not exceeding 20% when glaucoma medication scores were comparable, and 4) need for additional glaucoma surgery. The safety outcomes included intra- and post-operative adverse events and changes in the best-corrected visual acuity and visual field. RESULTS The study comprised 55 eyes in the iStent and 105 in the inject W groups. At 12 months, treatment success was achieved in 66.0% of iStent and 78.4% of inject W eyes. The mean IOP was lower, and the percent reduction from baseline was equal in iStent-treated eyes (8.0% reduction, 14.8 mmHg to 13.7 mmHg, P<0.01) and inject W-treated eyes (11.9% reduction, 15.0 mmHg to 13.8 mmHg, P<0.01) (between-group comparison, P = 0.23). The mean medication burden decreased significantly from 2.5 to 1.1 for iStent (55.0% reduction, P<0.01) and 2.9 to 1.7 for iStent inject (46.8% reduction, P<0.01), with no significant differences between the two groups (P = 0.17). Both devices exhibited excellent safety. CONCLUSIONS Both devices significantly reduced IOP and glaucoma medication 12 months post-operatively. The outcome measures did not differ significantly between the two groups, and lower baseline IOP was predictive of surgical failure.
Collapse
Affiliation(s)
- Shuu Morita
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Yoshihito Sakanishi
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Ikari Riyu
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Satoshi Watanabe
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Nobuyuki Ebihara
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| |
Collapse
|
8
|
Khaimi MA, Koerber N, Ondrejka S, Gallardo MJ. Consistency in Standalone Canaloplasty Outcomes Using the iTrack Microcatheter. Clin Ophthalmol 2024; 18:173-183. [PMID: 38250597 PMCID: PMC10799572 DOI: 10.2147/opth.s441113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 01/05/2024] [Indexed: 01/23/2024] Open
Abstract
Purpose To study the consistency in outcomes of standalone canaloplasty performed via an ab-interno surgical technique in reducing intraocular pressure (IOP) and number of medications in uncontrolled open-angle glaucoma (OAG) eyes over a 12-month period. Methods This retrospective multicenter case series included patients who underwent standalone canaloplasty via an ab-interno surgical technique using the iTrack microcatheter (Nova Eye, Inc., Fremont, USA) and had preoperative uncontrolled OAG (IOP≥18mmHg) along with no previous glaucoma surgery. The iTrack microcatheter is used to circumnavigate 360° and viscodilate Schlemm's canal. Consistency of IOP and medications reduction on an eye-by-eye basis were evaluated to understand the outcomes in each single eye. Results Sixty-four eyes of 60 patients (age 71.5±13.4 years) were included. Six eyes (9%) that underwent additional glaucoma surgery were considered a failure and were subsequently excluded from analysis. At 12 months, IOP was reduced in 57 of the 58 (89%) remaining eyes; one eye had the same IOP with a reduced number of medications. Of the 57/58 eyes with a reduced IOP: 44 eyes (69%) required fewer medications; 12 eyes (19%) required the same number of medications. Of these 58 eyes, 78% of eyes had a ≥20% reduction in IOP compared to baseline; 69% eyes had a postoperative IOP ≤15 mmHg, and 86% eyes ≤18 mmHg at 12 months. Forty percent of the eyes were medication-free at 12 months compared to none at baseline. Conclusion Canaloplasty performed via an ab-interno surgical technique as a standalone procedure consistently reduced IOP and glaucoma medications in almost all eyes.
Collapse
Affiliation(s)
- Mahmoud A Khaimi
- Dean McGee Eye Institute – Oklahoma Health Center, Oklahoma City, OK, USA
| | | | | | | |
Collapse
|
9
|
Qin Q, Zhang C, Yu N, Jia F, Liu X, Zhang Q, Chen M, Wang K. Development and material characteristics of glaucoma surgical implants. ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH 2023; 3:171-179. [PMID: 38106549 PMCID: PMC10724012 DOI: 10.1016/j.aopr.2023.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Revised: 09/12/2023] [Accepted: 09/21/2023] [Indexed: 12/19/2023]
Abstract
BACKGROUND Glaucoma is the leading cause of irreversible blindness worldwide. The reduction of intraocular pressure has proved to be the only factor which can be modified in the treatment, and surgical management is one of the important methods for the treatment of glaucoma patients. MAIN TEXT In order to increase aqueous humor outflow and further reduce intraocular pressure, various drainage implants have been designed and applied in clinical practice. From initial Molteno, Baerveldt and Ahmed glaucoma implants to the Ahmed ClearPath device, Paul glaucoma implant, EX-PRESS and the eyeWatch implant, to iStent, Hydrus, XEN, PreserFlo, Cypass, SOLX Gold Shunt, etc., glaucoma surgical implants are currently undergoing a massive transformation on their structures and performances. Multitudinous materials have been used to produce these implants, from original silicone and porous polyethylene, to gelatin, stainless steel, SIBS, titanium, nitinol and even 24-carat gold. Moreover, the material geometry, size, rigidity, biocompatibility and mechanism (valved versus nonvalved) among these implants are markedly different. In this review, we discussed the development and material characteristics of both conventional glaucoma drainage devices and more recent implants, such as the eyeWatch and the new minimally invasive glaucoma surgery (MIGS) devices. CONCLUSIONS Although different in design and materials, these delicate glaucoma surgical implants have widely expanded the glaucoma surgical methods, and improved the success rate and safety of glaucoma surgery significantly. However, all of these glaucoma surgical implants have various limitations and should be used for different glaucoma patients at different conditions.
Collapse
Affiliation(s)
- Qiyu Qin
- Department of Ophthalmology, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Zhejiang Provincial Key Lab of Ophthalmology, Hangzhou, China
| | - Chengshou Zhang
- Department of Ophthalmology, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Zhejiang Provincial Key Lab of Ophthalmology, Hangzhou, China
| | - Naiji Yu
- Department of Ophthalmology, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Zhejiang Provincial Key Lab of Ophthalmology, Hangzhou, China
| | - Fan Jia
- MOE Key Laboratory of Macromolecule Synthesis and Functionalization of Ministry of Education, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou, China
- Key Laboratory of Cardiovascular Intervention and Regenerative Medicine of Zhejiang Province, Department of Cardiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Xin Liu
- Department of Ophthalmology, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Zhejiang Provincial Key Lab of Ophthalmology, Hangzhou, China
| | - Qi Zhang
- Department of Ophthalmology, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Zhejiang Provincial Key Lab of Ophthalmology, Hangzhou, China
| | - Min Chen
- Department of Ophthalmology, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Zhejiang Provincial Key Lab of Ophthalmology, Hangzhou, China
| | - Kaijun Wang
- Department of Ophthalmology, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Zhejiang Provincial Key Lab of Ophthalmology, Hangzhou, China
| |
Collapse
|
10
|
Balas M, Mathew DJ. Minimally Invasive Glaucoma Surgery: A Review of the Literature. Vision (Basel) 2023; 7:54. [PMID: 37606500 PMCID: PMC10443347 DOI: 10.3390/vision7030054] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 07/24/2023] [Accepted: 08/17/2023] [Indexed: 08/23/2023] Open
Abstract
Minimally invasive glaucoma surgery (MIGS) has emerged as a novel approach in the glaucoma treatment spectrum, offering a range of diverse procedures and devices aimed at reducing intraocular pressure (IOP). MIGS can be broadly classified into several categories: those that enhance trabecular outflow (Trabectome, iStent, Hydrus Microstent, Kahook Dual Blade, high frequency deep sclerotomy, and gonioscopy-assisted transluminal trabeculotomy), those that augment suprachoroidal outflow (CyPass Microstent and iStent Supra), those that target Schlemm's canal (TRAB360 and the OMNI Surgical System, Streamline, and Ab Interno Canaloplasty), and conjunctival bleb-forming procedures (EX-PRESS Glaucoma Filtration Device, Xen Gel Stent and PreserFlo MicroShunt). MIGS is considered to have a shorter surgical time and fewer severe complications when compared to traditional glaucoma surgeries such as trabeculectomy and glaucoma drainage device implantation (Ahmed, Baerveldt, and Molteno valves). This literature review comprehensively examines the distinct MIGS devices and procedures, their underlying mechanisms, and clinical outcomes, emphasizing the importance of evaluating the efficacy and complications of each approach individually. As the field of MIGS continues to evolve, it is crucial to prioritize high-quality, long-term studies to better understand the safety and effectiveness of these innovative interventions in glaucoma management.
Collapse
Affiliation(s)
- Michael Balas
- Temerty Faculty of Medicine, University of Toronto, Toronto, ON M5S 1A8, Canada;
| | - David J. Mathew
- Donald K. Johnson Eye Institute, Krembil Research Institute, University Health Network, Toronto, ON M5T 0S8, Canada
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, ON M5T 2S8, Canada
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON M5S 1A8, Canada
| |
Collapse
|
11
|
Wagner IV, Ang B, Checo L, Simsek D, Draper C, Dorairaj S. Spotlight on Schlemm's Canal MicroStent Injection in Patients with Glaucoma. Clin Ophthalmol 2023; 17:1557-1564. [PMID: 37288002 PMCID: PMC10243342 DOI: 10.2147/opth.s388293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 05/30/2023] [Indexed: 06/09/2023] Open
Abstract
Minimally invasive glaucoma surgery (MIGS) has revolutionized glaucoma care with its favorable safety profile and ability to delay or minimize the need for traditional, bleb-based procedures. Microstent device implantation is a type of angle-based MIGS, which reduces intraocular pressure (IOP) through bypass of the juxtacanalicular trabecular meshwork (TM) and facilitation of aqueous outflow into the Schlemm's canal. Although there are limited microstent devices on the market, multiple studies have evaluated the safety and efficacy of iStent® (Glaukos Corp.), iStent Inject® (Glaukos Corp.), and Hydrus® Microstent (Alcon) in the treatment of mild-to-moderate open-angle glaucoma, with and without concurrent phacoemulsification. This review attempts to provide a comprehensive evaluation of injectable angle-based microstent MIGS devices in the treatment of glaucoma.
Collapse
Affiliation(s)
| | - Bryan Ang
- Department of Ophthalmology, Tan Tock Seng Hospital, Singapore
| | - Leticia Checo
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USA
| | - Derya Simsek
- Department of Ophthalmology, Baskent University Medical School, Ankara, Turkey
| | | | - Syril Dorairaj
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USA
| |
Collapse
|
12
|
Klabe K, Rüfer F. [Minimally invasive glaucoma surgery-Comparison of angle based procedures]. DIE OPHTHALMOLOGIE 2023; 120:358-371. [PMID: 37010578 DOI: 10.1007/s00347-023-01844-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Accepted: 03/07/2023] [Indexed: 04/04/2023]
Abstract
Surgical procedures are playing an increasing role in the care of patients with glaucoma. Within the last decade, new surgical procedures have been established, which are summarized under the term minimally invasive glaucoma surgery (MIGS). A wide variety of different procedures are aimed at the structures in the angle of the anterior chamber, such as the trabecular meshwork and Schlemm's canal, to improve the physiological outflow or to improve the alternative uveoscleral outflow. The implementation of the treatment goal differs in the individual procedures, as does the maximum pressure reduction that can be achieved. Compared to trabeculectomy with the use of cytostatic agents, the achievable pressure reduction is usually significantly lower. In contrast, the significantly lower intraoperative and postoperative complication rates are emphasized as an advantage of these procedures. With increasing clinical experience and the growth of sufficient data on these new surgical procedures, a well-founded classification in the treatment algorithm of glaucoma surgery becomes easier; nevertheless, due to the small differences with respect to efficacy and safety profile, the final decision for an individual procedure often remains dependent on the surgeon's personal preferences.
Collapse
Affiliation(s)
- Karsten Klabe
- Breyer Kaymak Klabe Augenchirurgie, Martin-Luther-Platz 22, 40212, Düsseldorf, Deutschland.
| | | |
Collapse
|
13
|
Saeed E, Gołaszewska K, Dmuchowska DA, Zalewska R, Konopińska J. The PreserFlo MicroShunt in the Context of Minimally Invasive Glaucoma Surgery: A Narrative Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:2904. [PMID: 36833599 PMCID: PMC9957246 DOI: 10.3390/ijerph20042904] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 01/29/2023] [Accepted: 02/01/2023] [Indexed: 05/13/2023]
Abstract
Recently, the quest for novel glaucoma surgical techniques and devices has been underway. Trabeculectomy remains the gold standard, but it requires the implantation of glaucoma drainage devices and frequent follow-ups, and it also carries a high risk of serious complications. The need for less invasive and safer procedures has led to the development of minimally invasive glaucoma surgery (MIGS), particularly for patients with mild-to-moderate disease. Among them, minimally invasive bleb surgery seems to be effective in classical glaucoma surgery, while maintaining MIGS benefits. The relatively new PreserFlo® MicroShunt (Santen, Osaka, Japan) is registered in Europe. It was released in 2019 for the treatment of patients with early-to-advanced open-angle glaucoma, where intraocular pressure (IOP) remains uncontrolled while on maximum tolerated medication and/or where glaucoma progression warrants surgery. This review focuses on the place of the PreserFlo MicroShunt, characterized by ab externo implantation, among MIGS procedures, discussing its advantages and disadvantages. The mechanisms of action, technical aspects, efficacy, and safety issues are summarized. The surgical technique, its efficacy, and safety profile are described, and directions for future studies are indicated. The PreserFlo MicroShunt ensures a high safety profile, minimal anatomical disruption, meaningful IOP-lowering effect, and ease of use for patients and physicians.
Collapse
Affiliation(s)
| | | | | | | | - Joanna Konopińska
- Department of Ophthalmology, Medical University of Bialystok, Kilinskiego 1 STR, 15-089 Bialystok, Poland
| |
Collapse
|
14
|
Minimally Invasive Glaucoma Surgery: Safety of Individual Devices. J Clin Med 2022; 11:jcm11226833. [PMID: 36431310 PMCID: PMC9696404 DOI: 10.3390/jcm11226833] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 10/30/2022] [Accepted: 11/11/2022] [Indexed: 11/22/2022] Open
Abstract
Primary open-angle glaucoma progression in those already on maximal medical therapy has traditionally been treated with trabeculectomy, a surgical procedure that carries a high degree of morbidity. In the last few decades, significant advances have been made in the field of minimally invasive glaucoma surgery (MIGS) devices, which aim to defer or prevent trabeculectomy via less arduous surgical techniques in certain types of glaucoma. Although reviews have been published examining the efficacy of various MIGS techniques, no article synthesises the comparative safety of all available devices. We performed a literature review examining the safety of MIGS devices. Fifteen devices were included, variously attempting to increase aqueous outflow through the trabecular meshwork or the suprachoroidal space, shunting into the subconjunctival space, or reducing aqueous production through ciliary body ablation. Notably, the earliest product attempting to increase outflow to the suprachoroidal space, Alcon's CyPass Micro-Stent, was withdrawn from the market due to concerns regarding increased corneal endothelial cell loss at five years post-implantation. All other devices were described as well-tolerated, with the most common adverse effects including hyphaema, intraocular pressure spikes, and device migration or obstruction. MIGS devices are purported to be uniformly safe, and many studies report no statistically significant increased complications beyond those associated with cataract surgery alone. It is important to note, however, the generally poor quality of current studies, with a dearth of randomised, or even prospective, data, and a large proportion of studies funded by device producers.
Collapse
|
15
|
Luo J, Tan G, Thong KX, Kafetzis KN, Vallabh N, Sheridan CM, Sato Y, Harashima H, Tagalakis AD, Yu-Wai-Man C. Non-Viral Gene Therapy in Trabecular Meshwork Cells to Prevent Fibrosis in Minimally Invasive Glaucoma Surgery. Pharmaceutics 2022; 14:pharmaceutics14112472. [PMID: 36432663 PMCID: PMC9693853 DOI: 10.3390/pharmaceutics14112472] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 11/07/2022] [Accepted: 11/12/2022] [Indexed: 11/18/2022] Open
Abstract
The primary cause of failure for minimally invasive glaucoma surgery (MIGS) is fibrosis in the trabecular meshwork (TM) that regulates the outflow of aqueous humour, and no anti-fibrotic drug is available for intraocular use in MIGS. The myocardin-related transcription factor/serum response factor (MRTF/SRF) pathway is a promising anti-fibrotic target. This study aims to utilise a novel lipid nanoparticle (LNP) to deliver MRTF-B siRNA into human TM cells and to compare its effects with those observed in human conjunctival fibroblasts (FF). Two LNP formulations were prepared with and without the targeting peptide cΥ, and with an siRNA concentration of 50 nM. We examined the biophysical properties and encapsulation efficiencies of the LNPs, and evaluated the effects of MRTF-B silencing on cell viability, key fibrotic genes expression and cell contractility. Both LNP formulations efficiently silenced MRTF-B gene and were non-cytotoxic in TM and FF cells. The presence of cΥ made the LNPs smaller and more cationic, but had no significant effect on encapsulation efficiency. Both TM and FF cells also showed significantly reduced contractibility after transfection with MRTF-B siRNA LNPs. In TM cells, LNPs with cΥ achieved a greater decrease in contractility compared to LNPs without cΥ. In conclusion, we demonstrate that the novel CL4H6-LNPs are able to safely and effectively deliver MRTF-B siRNA into human TM cells. LNPs can serve as a promising non-viral gene therapy to prevent fibrosis in MIGS.
Collapse
Affiliation(s)
- Jinyuan Luo
- Faculty of Life Sciences & Medicine, King’s College London, London SE1 7EH, UK
- Department of Ophthalmology, Renmin Hospital of Wuhan University, Wuhan 430060, China
| | - Greymi Tan
- Faculty of Life Sciences & Medicine, King’s College London, London SE1 7EH, UK
| | - Kai Xin Thong
- Faculty of Life Sciences & Medicine, King’s College London, London SE1 7EH, UK
| | | | - Neeru Vallabh
- Department of Eye and Vision Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool L69 3BX, UK
| | - Carl M. Sheridan
- Department of Eye and Vision Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool L69 3BX, UK
| | - Yusuke Sato
- Faculty of Pharmaceutical Sciences, Hokkaido University, Kita-12, Nishi-6, Kita-ku, Sapporo 060-0812, Japan
| | - Hideyoshi Harashima
- Faculty of Pharmaceutical Sciences, Hokkaido University, Kita-12, Nishi-6, Kita-ku, Sapporo 060-0812, Japan
| | - Aristides D. Tagalakis
- Department of Biology, Edge Hill University, Ormskirk L39 4QP, UK
- Correspondence: (A.D.T.); (C.Y.-W.-M.); Tel.: +44-(0)1695-650923 (A.D.T.); +44-(0)2071-881504 (C.Y.-W.-M.)
| | - Cynthia Yu-Wai-Man
- Faculty of Life Sciences & Medicine, King’s College London, London SE1 7EH, UK
- Correspondence: (A.D.T.); (C.Y.-W.-M.); Tel.: +44-(0)1695-650923 (A.D.T.); +44-(0)2071-881504 (C.Y.-W.-M.)
| |
Collapse
|
16
|
Clement C, Howes F, Ioannidis A, Shiu M, Manning D, Lusthaus JA, Skalicky SE, Goodwin TW. Multicenter Effectiveness and Disease Stability Through 3 Years After iStentTrabecular Micro-Bypass with Phacoemulsification in Glaucoma and Ocular Hypertension. Clin Ophthalmol 2022; 16:2955-2968. [PMID: 36071724 PMCID: PMC9444145 DOI: 10.2147/opth.s373290] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose To evaluate 3-year safety and efficacy of two second-generation trabecular micro-bypass stents. (iStent inject®) with phacoemulsification. Materials and Methods This multicenter retrospective study of iStent inject implantation with phacoemulsification included data from eight surgeons across Australia. Eyes with cataract and mild to advanced glaucoma [predominantly primary open-angle (POAG), primary angle closure (PAC), or normal-tension (NTG) glaucoma] or ocular hypertension (OHT) were included. Study assessments included intraocular pressure (IOP); number of ocular hypotensive medications; proportions of eyes with 0, 1, 2, or ≥3 IOP-lowering medications; IOP ≤15 mmHg or ≤18 mmHg; visual fields (VF); retinal nerve fiber layer thickness (RNFL); central corneal thickness (CCT); intraoperative complications; adverse events; and secondary surgeries. Results A total of 273 eyes underwent surgery and had 36-month follow-up. At 36 months versus preoperative, mean IOP decreased by 15.5% (16.4±4.6 mmHg to 13.9±3.5 mmHg; p<0.001), and 70.3% of eyes achieved IOP of ≤15 mmHg (versus 49.1% preoperatively; p<0.001). The mean medication burden decreased by 68.5% (from 1.51±1.17 to 0.48±0.89 medications; p<0.001); 71.4% of eyes were medication-free (versus 21.6% preoperatively; p<0.001), while 6.2% of eyes were on ≥3 medications (versus 22.3% preoperatively; p<0.001); 96.3% of eyes maintained or reduced medications vs preoperative. Significant IOP and medication reductions occurred across glaucoma subtypes (POAG, PAC, NTG, OHT): 13–22% for IOP (p<0.05 for all) and 42–94% for medication (p<0.05 for all). Favorable safety included few adverse events; stable VF, RNFL, and CCT; and filtering surgery in only 8 eyes (2.9%) over 3 years. Conclusion In this multicenter cohort from 8 surgeons across Australia, significant IOP and medication reductions were sustained through 3 years after iStent inject implantation with phacoemulsification. Results were favorable across different glaucoma subtypes (including POAG, PAC, NTG, OHT), severities, and surgeons, thereby underscoring the real-world relevance and efficacy of iStent inject implantation for glaucoma treatment.
Collapse
Affiliation(s)
- Colin Clement
- Eye Associates, Sydney, NSW, Australia
- Fairfield Eye Surgery, Fairfield, NSW, Australia
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Correspondence: Colin Clement, Eye Associates, Level 4, 187 Macquarie Street, Sydney, NSW, 2000, Australia, Tel +612 9247 9972, Email
| | - Frank Howes
- Eye & Laser Centre, Gold Coast, QLD, Australia
| | | | | | - David Manning
- Hunter Cataract & Eye Centre, Charlestown, NSW, Australia
| | - Jed A Lusthaus
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Eyehaus, Sydney, NSW, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | | |
Collapse
|