Berteloot S, Correia Barão R, Abegão Pinto L, Vandewalle E, Stalmans I, Lemmens S. Treatment Outcomes Comparing the Paul and Baerveldt Glaucoma Implants After One Year of Follow-Up. J Glaucoma 2024; 33:594-600. [PMID: 38700482 PMCID: PMC11319072 DOI: 10.1097/ijg.0000000000002366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Accepted: 01/20/2024] [Indexed: 05/05/2024]
Abstract
PRCIS In reducing intraocular pressure (IOP), Paul (PGI) and Baerveldt (BGI) glaucoma implants are safe and effective in patients with glaucoma. OBJECTIVE To compare efficacy and safety profiles of the PGI and BGI in the treatment of medically uncontrolled glaucoma at 1 year of follow-up. METHODS Retrospective analysis of patients implanted with a PGI or BGI with a minimum of 12 months follow-up. The primary outcome was surgical success defined as IOP ≥6 and ≤18 mm Hg and at least 20% IOP reduction from baseline. Secondary outcomes included IOP measurements, number of medications, and complications. RESULTS Twenty-three patients implanted with PGI and 27 with BGI were included. At last visit (12 mo), mean IOP had decreased from 23.7 ± 6.9 to 0.1 ± 2.9 mm Hg in the PGI group versus 26 ± 7.3 to 10.4 ± 4.9 mm Hg with the BGI ( P < 0.001 for both comparisons). Overall qualified success rates were similar between groups (PGI 91% vs BGI 89%, P = 0.784). IOP was significantly lower in the PGI at week 1 and month 1 of follow-up versus the BGI (13.6 ± 6.1 vs 20.1 ± 7.4; 14.6±3.8 vs 21.2 ± 5.8 mm Hg; P < 0.002 for both) with a lower number of medications (1.57 ± 1.47 vs 2.52 ± 1.16 at mo 1, P = 0.015). Most complications were minor and similar in both groups. CONCLUSION Both PGI and BGI are safe and effective in reducing IOP in patients with glaucoma, with similar success rates.
Collapse
Affiliation(s)
| | - Rafael Correia Barão
- Department of Ophthalmology, Hospital de Santa Maria, CHULN
- Visual Sciences Study Center (CECV), Lisbon Academic Medical Center (CAML), Faculty of Medicine, University of Lisbon, Lisbon, Portugal
| | - Luís Abegão Pinto
- Department of Ophthalmology, Hospital de Santa Maria, CHULN
- Visual Sciences Study Center (CECV), Lisbon Academic Medical Center (CAML), Faculty of Medicine, University of Lisbon, Lisbon, Portugal
| | - Evelien Vandewalle
- Department of Ophthalmology, University Hospitals of Leuven
- Department of Neurosciences, Research Group Ophthalmology, KU Leuven, Leuven, Belgium
| | - Ingeborg Stalmans
- Department of Ophthalmology, University Hospitals of Leuven
- Department of Neurosciences, Research Group Ophthalmology, KU Leuven, Leuven, Belgium
| | - Sophie Lemmens
- Department of Ophthalmology, University Hospitals of Leuven
- Department of Neurosciences, Research Group Ophthalmology, KU Leuven, Leuven, Belgium
| |
Collapse
|
2
|
Tang M, Anchala AR, Tanna AP. Intraluminal Suture Placement for Management of Hypotony After Glaucoma Drainage Device Surgery. J Glaucoma 2024; 33:607-611. [PMID: 38546238 DOI: 10.1097/ijg.0000000000002381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 03/03/2024] [Indexed: 08/15/2024]
Abstract
PRCIS Intraluminal 3-0 Supramid stent placement can be an effective long-term solution for hypotony after glaucoma drainage device surgery. This procedure may obviate the need for conjunctival dissection. In some cases, additional procedures are required. PURPOSE To describe the utility of implantation of a multifilament polyamide suture (Supramid) in the tube lumen to reverse hypotony after glaucoma drainage device (GDD) surgery. PATIENTS Patients who underwent tube revision with intraluminal placement of a 3-0 Supramid stent, with or without external ligature, to manage hypotony following GDD surgery between January 2010 and October 2020. METHODS Resolution of hypotony was defined as IOP >5 mm Hg and the absence of hypotony-related structural abnormalities. Overall success was the absence of failure criteria (IOP ≤5 mm Hg, >21 mm Hg, or <20% reduction below baseline IOP after 3 months for 2 consecutive study visits; additional glaucoma surgery; or loss of light perception), with or without adjunctive ocular hypotensive therapy. RESULTS Nine eyes of 9 patients underwent placement of a 3-0 Supramid stent with a resolution of hypotony in all eyes with a mean follow-up duration of 33.3 ±24.0 months. Overall success was achieved in 7 of 9 eyes. Four eyes required intervention after stent placement: 1 eye required selective laser trabeculoplasty followed by replacement of the original stent with a shorter 3-0 Supramid suture and external ligature; 1 eye underwent revision for tube exposure; and 2 eyes underwent laser suture lysis to release an external suture ligature. CONCLUSIONS In cases of hypotony after GDD, particularly when it is desirable to reduce the extent of additional conjunctival dissection, intraluminal placement of a 3-0 Supramid stent via an intracameral approach can be an effective long-term solution. Postoperative adjustments were required in many cases.
Collapse
Affiliation(s)
- Minjia Tang
- Department of Ophthalmology, Northwestern University Feinberg School of Medicine, Chicago, IL
| | | | - Angelo P Tanna
- Department of Ophthalmology, Northwestern University Feinberg School of Medicine, Chicago, IL
| |
Collapse
|
3
|
Mladenovic T, Zivic F, Petrovic N, Njezic S, Pavic J, Kotorcevic N, Milenkovic S, Grujovic N. Application of Silicone in Ophthalmology: A Review. MATERIALS (BASEL, SWITZERLAND) 2024; 17:3454. [PMID: 39063747 PMCID: PMC11278226 DOI: 10.3390/ma17143454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 07/01/2024] [Accepted: 07/09/2024] [Indexed: 07/28/2024]
Abstract
This paper reviews the latest trends and applications of silicone in ophthalmology, especially related to intraocular lenses (IOLs). Silicone, or siloxane elastomer, as a synthetic polymer, has excellent biocompatibility, high chemical inertness, and hydrophobicity, enabling wide biomedical applications. The physicochemical properties of silicone are reviewed. A review of methods for mechanical and in vivo characterization of IOLs is presented as a prospective research area, since there are only a few available technologies, even though these properties are vital to ensure medical safety and suitability for clinical use, especially if long-term function is considered. IOLs represent permanent implants to replace the natural lens or for correcting vision, with the first commercial foldable lens made of silicone. Biological aspects of posterior capsular opacification have been reviewed, including the effects of the implanted silicone IOL. However, certain issues with silicone IOLs are still challenging and some conditions can prevent its application in all patients. The latest trends in nanotechnology solutions have been reviewed. Surface modifications of silicone IOLs are an efficient approach to further improve biocompatibility or to enable drug-eluting function. Different surface modifications, including coatings, can provide long-term treatments for various medical conditions or medical diagnoses through the incorporation of sensory functions. It is essential that IOL optical characteristics remain unchanged in case of drug incorporation and the application of nanoparticles can enable it. However, clinical trials related to these advanced technologies are still missing, thus preventing their clinical applications at this moment.
Collapse
Affiliation(s)
- Tamara Mladenovic
- Faculty of Engineering, University of Kragujevac, Sestre Janjic 6, 34000 Kragujevac, Serbia; (T.M.); (J.P.); (N.K.); (S.M.); (N.G.)
- Institute for Information Technologies Kragujevac, University of Kragujevac, Jovana Cvijica bb, 34000 Kragujevac, Serbia
| | - Fatima Zivic
- Faculty of Engineering, University of Kragujevac, Sestre Janjic 6, 34000 Kragujevac, Serbia; (T.M.); (J.P.); (N.K.); (S.M.); (N.G.)
| | - Nenad Petrovic
- Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac, Serbia;
| | - Sasa Njezic
- Faculty of Medicine, University of Banja Luka, Save Mrkalja 14, 78000 Banja Luka, Bosnia and Herzegovina;
| | - Jelena Pavic
- Faculty of Engineering, University of Kragujevac, Sestre Janjic 6, 34000 Kragujevac, Serbia; (T.M.); (J.P.); (N.K.); (S.M.); (N.G.)
- Institute for Information Technologies Kragujevac, University of Kragujevac, Jovana Cvijica bb, 34000 Kragujevac, Serbia
| | - Nikola Kotorcevic
- Faculty of Engineering, University of Kragujevac, Sestre Janjic 6, 34000 Kragujevac, Serbia; (T.M.); (J.P.); (N.K.); (S.M.); (N.G.)
| | - Strahinja Milenkovic
- Faculty of Engineering, University of Kragujevac, Sestre Janjic 6, 34000 Kragujevac, Serbia; (T.M.); (J.P.); (N.K.); (S.M.); (N.G.)
| | - Nenad Grujovic
- Faculty of Engineering, University of Kragujevac, Sestre Janjic 6, 34000 Kragujevac, Serbia; (T.M.); (J.P.); (N.K.); (S.M.); (N.G.)
| |
Collapse
|
4
|
Wagner IV, Stewart MW, Dorairaj SK. Updates on the Diagnosis and Management of Glaucoma. Mayo Clin Proc Innov Qual Outcomes 2022; 6:618-635. [PMID: 36405987 PMCID: PMC9673042 DOI: 10.1016/j.mayocpiqo.2022.09.007] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Glaucoma is the leading cause of blindness throughout the world (after cataracts); therefore, general physicians should be familiar with the diagnosis and management of affected patients. Glaucomas are usually categorized by the anatomy of the anterior chamber angle (open vs narrow/closed), rapidity of onset (acute vs chronic), and major etiology (primary vs secondary). Most glaucomas are primary (ie, without a contributing comorbidity); however, several coexisting ophthalmic conditions may serve as the underlying etiologies of secondary glaucomas. Chronic glaucoma occurs most commonly; thus, regular eye examinations should be performed in at-risk patients to prevent the insidious loss of vision that can develop before diagnosis. Glaucoma damages the optic nerve and retinal nerve fiber layer, leading to peripheral and central visual field defects. Elevated intraocular pressure (IOP), a crucial determinant of disease progression, remains the only modifiable risk factor; thus, all current treatments (medications, lasers, and operations) aim to reduce the IOP. Pharmacotherapy is the usual first-line therapy, but noncompliance, undesirable adverse effects, and cost limit effectiveness. Laser and surgical treatments may lower IOP significantly over long periods and may be more cost effective than pharmacotherapy, but they are plagued by greater procedural risks and frequent treatment failures. Traditional incisional procedures have recently been replaced by several novel, minimally invasive glaucoma surgeries with improved safety profiles and only minimal decreases in efficacy. Minimally invasive glaucoma surgeries have dramatically transformed the surgical management of glaucoma; nevertheless, large, randomized trials are required to assess their long-term efficacy.
Collapse
Key Words
- ACA, anterior chamber angle
- ACG, angle-closure glaucoma
- AIT, ab-interno trabeculotomy
- CAI, carbonic anhydrase inhibitor
- CE, cataract extraction
- GDD, glaucoma drainage device
- IOP, intraocular pressure
- KDB, Kahook Dual Blade
- MIGS, minimally invasive glaucoma surgery
- MMC, mitomycin C
- OAG, open-angle glaucoma
- OCT, optical coherence tomography
- ONH, optic nerve head
- PGA, prostaglandin analog
- PGI, PAUL glaucoma implant
- POAG, primary open-angle glaucoma
- RNFL, retinal nerve fiber layer
- SLT, selective laser trabeculoplasty
- TM, trabecular meshwork
Collapse
Affiliation(s)
- Isabella V. Wagner
- Department of Ophthalmology, Mayo Clinic School of Medicine, Jacksonville, FL
| | - Michael W. Stewart
- Department of Ophthalmology, Mayo Clinic School of Medicine, Jacksonville, FL
| | - Syril K. Dorairaj
- Department of Ophthalmology, Mayo Clinic School of Medicine, Jacksonville, FL
| |
Collapse
|
5
|
Al Houssien AO, Al Owaifeer AM, Ahmad SI, Owaidhah O, Malik R. Efficacy and Safety of Temporary in situ Stenting of Ahmed Glaucoma Valve in Eyes with High Risk of Hypotony. Clin Ophthalmol 2022; 16:3689-3700. [DOI: 10.2147/opth.s383489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 10/11/2022] [Indexed: 11/10/2022] Open
|
6
|
Outcomes of Anterior Chamber, Sulcus, and Pars Plana Glaucoma Drainage Device Placement in Glaucoma Patients. J Ophthalmol 2022; 2022:5947992. [PMID: 35909463 PMCID: PMC9328986 DOI: 10.1155/2022/5947992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 07/01/2022] [Indexed: 12/01/2022] Open
Abstract
Purpose To assess outcomes of anterior chamber (AC), sulcus, and pars plana (PP) glaucoma drainage device (GDD) placement in glaucoma patients. Patients and Methods. Retrospective evaluation of glaucoma patients who underwent GDD insertion in the AC, sulcus, or PP at Massachusetts Eye and Ear between November 2016 and May 2021. Patients who received AC, sulcus, and pars plana tubes were selected using simple random sampling, and the first 40 patients meeting inclusion criteria were analyzed. Main outcome measures were cumulative success probabilities from Kaplan-Meier (KM) analyses, intraocular pressure (IOP), medication burden, and complication rates. Results The PP group had a larger proportion of Ahmed GDDs and was younger on average with less severe glaucoma compared to patients with AC or sulcus tubes. The PP group had a higher proportion of mixed-mechanism glaucoma and lower proportion of primary open-angle glaucoma. With success defined as IOP reduction ≥20% and 5 < IOP ≤ 21 mm Hg, the Kaplan-Meier cumulative success probabilities for all three GDD locations were not significantly different. No significant differences were found in complication rates between all groups after 3 months. Patients with PP GDD had significantly lower medication burden than those with AC or sulcus GDDs up to 1.5 years postoperatively (1.7 ± 1.1, 3.0 ± 1.4, and 2.8 ± 1.2 for PP, AC, and sulcus, respectively; P=0.017). Conclusion PP GDDs may be more effective in lowering medication burden than AC or sulcus tubes without compromising long-term safety.
Collapse
|
7
|
Izquierdo-Villavicencio JC, Rubio-Lastra B, Mejías-Smith JA, Agudelo N. Primary outcomes of Baerveldt glaucoma implants with a modified technique to control intraocular pressure in different cases of glaucoma. Int Ophthalmol 2021; 41:2547-2554. [PMID: 33770303 DOI: 10.1007/s10792-021-01813-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Accepted: 03/10/2021] [Indexed: 11/28/2022]
Abstract
INTRODUCTION To describe the outcomes of Baerveldt glaucoma implants implanted via a modified technique with regard to early intraocular pressure (IOP) reduction in cases of uncontrolled glaucoma. METHODS The medical records of patients who had Baerveldt glaucoma implants of 350 or 250 mm2 implanted via a modified technique and were followed up for a period of at least 6 months were reviewed. The primary outcome measures were the mean IOP and number of glaucoma medications at each visit. We evaluated complete success rates at 1 day, 1 week and 1 month, defined as IOP values [Formula: see text] 5 mmHg and ≤ 21 mmHg prior to ligature rupture. RESULTS A total of 42 eyes had Baerveldt glaucoma implants and met the inclusion criteria. The mean preoperative intraocular pressure (IOP) was 34.2 ± 11.2 mmHg. The postoperative mean IOP values were 15.1 mmHg ± 8.8 (p < 0.05), 17.7 ± 7.1 mmHg (p < 0.05), 12.3 ± 4.0 mm Hg (p < 0.05) at 1 day, 1 month, and 6 months, respectively. The rate of complete success on the first day was 78%, at the first month was 69%, and at 6 months was 95.2%. The number of glaucoma medications used was significantly lower at 6 months (P = < 0.001). CONCLUSION The modified surgical technique using Baerveldt implants enables a safe, effective, and reliable IOP control in early postoperative patients with uncontrolled glaucomas.
Collapse
Affiliation(s)
- Juan Carlos Izquierdo-Villavicencio
- Research Department, Instituto de Ojos Oftalmosalud, Javier Prado Este 1142, San Isidro, Lima, Peru.,Head of Sub-Specialty Department of Glaucoma at Instituto de Ojos Oftalmosalud, Lima, Peru
| | - Bárbara Rubio-Lastra
- Research Department, Instituto de Ojos Oftalmosalud, Javier Prado Este 1142, San Isidro, Lima, Peru.
| | - Josefina A Mejías-Smith
- Research Department, Instituto de Ojos Oftalmosalud, Javier Prado Este 1142, San Isidro, Lima, Peru
| | - Natalia Agudelo
- Research Department, Instituto de Ojos Oftalmosalud, Javier Prado Este 1142, San Isidro, Lima, Peru
| |
Collapse
|
8
|
Crichton P, Sanders E, Docherty G, Crichton A. Analysis of Efficacy and Safety of Pediatric Ahmed Glaucoma Valve (FP8) in Advanced Age Populations. J Glaucoma 2021; 30:164-169. [PMID: 33955945 DOI: 10.1097/ijg.0000000000001701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 09/22/2020] [Indexed: 11/27/2022]
Abstract
PRECIS The FP8 glaucoma valve was demonstrated to be reasonably safe with reliable results in an advanced age patient population. PURPOSE As life expectancy increases, a growing number of patients with glaucoma are of an advanced age. There are little to no data looking at glaucoma surgical treatment options in patients over the age of 85. Our study describes the safety and efficacy of the FP8 Ahmed glaucoma valve in this patient population. MATERIALS AND METHODS This was a retrospective study of patients over 85 years of age undergoing FP8 Ahmed glaucoma valve implantation. Preoperative age, sex, intraocular pressure (IOP), and number of glaucoma medications were recorded. Primary outcome variables were IOP and number of medications. Secondary outcome variables included any intraoperative or postoperative complications. RESULTS Mean IOP preoperatively was 26 mm Hg on an average of 3 glaucoma medications (n=56). IOP was significantly reduced at all time points in follow-up for an overall reduction of 42% at 1 year and 46% at 2 years. Mean IOP at 1 year follow-up was 15 mm Hg and 14 mm Hg at 2 years follow-up. Glaucoma medications were reduced from a mean of 3 preoperatively to 2 postoperatively. CONCLUSIONS Implantation of an FP8 Ahmed glaucoma valve is a relatively safe procedure to achieve satisfactory IOP and decreased reliance on glaucoma medications in an advanced age population.
Collapse
Affiliation(s)
- Paul Crichton
- Department of Ophthalmology and Visual Sciences, Faculty of Science, University of Alberta, Vancouver, BC
| | | | - Gavin Docherty
- Ophthalmology, University of Calgary, Calgary, AB, Canada
| | | |
Collapse
|
9
|
Koentjoro SL, Artini W, Soebijantoro I, Istiantoro VW, Rusmayani E, Sulastiwaty R, Djamal ZE, Akbar ASN, Yoserizal M. Comparison of complications after Ahmed versus Baerveldt implant in glaucoma patients: one year follow-up. Int J Ophthalmol 2020; 13:1908-1914. [PMID: 33344189 DOI: 10.18240/ijo.2020.12.10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Accepted: 08/27/2020] [Indexed: 11/23/2022] Open
Abstract
AIM To compare surgical results of the Ahmed and Baerveldt implant procedures in glaucoma patients at 1y follow-up at Jakarta Eye Center (JEC) Eye Hospitals. METHODS This cohort retrospective study was conducted on glaucoma patients aged ≥18y who had undergone Ahmed and Baerveldt implant surgery. Intraocular pressure (IOP), visual acuity, glaucoma medication, success rate, early and late postoperative complications, and the number of resurgeries were analyzed. RESULTS A total of 351 eyes in the Ahmed group and 94 eyes in the Baerveldt group were included in this study. At 1y follow-up, the mean IOP was found to be significantly lower in the Baerveldt group (13±4.47 mm Hg) compared to the Ahmed group (15.02±5.73 mm Hg; P=0.025). Glaucoma medication was required in both the Ahmed and Baerveldt groups (58.92% vs 71.67%). Comparable success rate was found in both groups. The Ahmed group revealed a complete and qualified success of 86.82%, and failure of 13.17%. Similarly, the Baerveldt group showed complete and qualified success in 87.75% and failure in 12.25% cases. In the Ahmed group, 11.97% early complications, 26.06% late complications and 9.97% resurgeries were observed. In comparison, in the Baerveldt group, 23.40% early complications, 30.95% late complications and 11.70% resurgeries were observed. CONCLUSION Both groups of glaucoma implants show significant IOP reduction, however, the Baerveldt implant group demonstrates greater IOP reduction with more failure rates and complications than the Ahmed implant group.
Collapse
Affiliation(s)
- Sara Listyani Koentjoro
- Glaucoma Division, Jakarta Eye Center Hospital, West Jakarta, Special District Region of Jakarta 11520, Indonesia
| | - Widya Artini
- Glaucoma Division, Jakarta Eye Center Hospital, West Jakarta, Special District Region of Jakarta 11520, Indonesia
| | - Iwan Soebijantoro
- Glaucoma Division, Jakarta Eye Center Hospital, West Jakarta, Special District Region of Jakarta 11520, Indonesia
| | - Vira Wardhana Istiantoro
- Glaucoma Division, Jakarta Eye Center Hospital, West Jakarta, Special District Region of Jakarta 11520, Indonesia
| | - Emma Rusmayani
- Glaucoma Division, Jakarta Eye Center Hospital, West Jakarta, Special District Region of Jakarta 11520, Indonesia
| | - Rini Sulastiwaty
- Glaucoma Division, Jakarta Eye Center Hospital, West Jakarta, Special District Region of Jakarta 11520, Indonesia
| | - Zeiras Eka Djamal
- Glaucoma Division, Jakarta Eye Center Hospital, West Jakarta, Special District Region of Jakarta 11520, Indonesia
| | - Arini Safira Nurul Akbar
- Glaucoma Division, Jakarta Eye Center Hospital, West Jakarta, Special District Region of Jakarta 11520, Indonesia
| | - Muhammad Yoserizal
- Glaucoma Division, Jakarta Eye Center Hospital, West Jakarta, Special District Region of Jakarta 11520, Indonesia
| |
Collapse
|
10
|
Kilgore KP, Wang F, Stern NC, Jamali Dogahe S, White LJ, Khanna CL. Health-related quality of life in Ahmed FP7, and Baerveldt 250 and 350 patients compared with medical controls. Br J Ophthalmol 2020; 106:356-361. [PMID: 33328185 DOI: 10.1136/bjophthalmol-2020-317856] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 10/14/2020] [Accepted: 10/30/2020] [Indexed: 12/14/2022]
Abstract
PURPOSE To compare health-related quality of life (HRQoL) in patients with Ahmed FP7 (FP7), Baerveldt 250 (B250) and Baerveldt 350 (B350) glaucoma drainage device (GDDs), and medically treated controls. METHODS This was a prospective cohort study from August 2017 to July 2019. The NEI 25-Item Visual Function Questionnaire (VFQ-25), the Adult Strabismus-20 questionnaire (AS-20) and the Diplopia Questionnaire were conducted ≥30 days postoperatively in GDD patients, on enrolment for controls. Age, sex, treatment type, visual acuity, mean deviation and diplopia were evaluated for association with HRQoL RESULTS: Of the 128 GDD patients enrolled, 35 (27.3%) had FP7, 32 (25.0%) had B250 and 61 (47.7%) had B350. In univariate analysis, decreased HRQoL was associated with younger age (r2 range 0.042-0.071), diplopia (r2 range 0.039-0.119), GDD treatment (r2 range 0.023-0.103), lower visual acuity (r2 range 0.021-0.215) and worse mean deviation (r2 range 0.029-0.131). All GDD groups had lower HRQoL subscores than the controls. HRQoL scores were lower compared with controls among B350 patients for AS-20 Self-perception subscale, B250 and B350 for Reading and General Function subscales, and FP7 and B350 for VFQ-25 Visual Functioning subscale. There were no significant differences among the GDDs. CONCLUSIONS Glaucoma patients with a younger age, diplopia, lower visual acuity, worse mean deviation or a GDD had lower HRQoL. Those with B350 had lower self-perception scores, consistent with previous reports in the literature. This subscale was not diminished in FP7 or B250, so the decreased self-perception scores may be due to greater visibility or awareness of the B350.
Collapse
Affiliation(s)
- Khin P Kilgore
- Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota, USA.,Department of Ophthalmology, Washington University in Saint Louis, Saint Louis, Missouri, USA
| | - Feng Wang
- Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota, USA.,Department of Ophthalmology, First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China
| | - Nicole C Stern
- Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota, USA
| | | | - Launia J White
- Department of Health Sciences Research, Mayo Clinic, Rochester, Minnesota, USA
| | - Cheryl L Khanna
- Department of Ophthalmology, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
11
|
Soebijantoro I, Noor NA. Tube Length Adjustment and Tube Trimming Technique in Refractory Glaucoma. Case Rep Ophthalmol Med 2020; 2020:8889448. [PMID: 32655960 PMCID: PMC7327559 DOI: 10.1155/2020/8889448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 06/10/2020] [Accepted: 06/15/2020] [Indexed: 11/17/2022] Open
Abstract
Secondary glaucoma may develop after vitreoretinal surgery as it is a known risk factor for its development. When the risk factors are more than one, for instance along with neovascular glaucoma (NVG), the secondary glaucoma may become recalcitrant and very difficult to manage. Surgical intervention is often warranted to control intraocular pressure (IOP) and prevent progressive glaucomatous damage in patients with refractory glaucoma, and glaucoma drainage implant may be preferred as the primary choice. We describe a patient who develop secondary glaucoma after vitrectomy and silicone oil (SO) injection due to unresolved vitreous hemorrhage in proliferative diabetic retinopathy (PDR) and subsequent NVG. Baerveldt glaucoma implant (BGI) was carried out and placed in the superotemporal quadrant with longer anterior chamber tube placement to prevent escape of SO through the tube. Qualified success was achieved with additional one fixed-drug combination (FDC). However, 3 years later, the tube was blocked by the iris tissue at the inferior edge of the pupil. Tube trimming was performed efficiently using a simple technique. The distal end of the tube was pulled out of the anterior chamber through a paracentesis just next to the tube entrance and trimmed to the appropriate length. More than a year after the surgery, IOP was still well controlled with the same FDC. Unfortunately, the visual acuity could not be recovered due to advanced PDR.
Collapse
|
12
|
Vijayakumar A, Pugazhenthan T, Sathish Babu M, Sajitha V. Ophthalmology and Otorhinolaryngology. TOXICOLOGICAL ASPECTS OF MEDICAL DEVICE IMPLANTS 2020:33-66. [DOI: 10.1016/b978-0-12-820728-4.00003-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
|
13
|
EyeWatch Rescue of Refractory Hypotony After Baerveldt Drainage Device Implantation: Description of a New Technique. J Glaucoma 2019; 29:e7-e10. [DOI: 10.1097/ijg.0000000000001417] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
14
|
Yadav KS, Sharma S. Implantable drainage devices in glaucoma: Quo vadis? Eur J Pharm Sci 2019; 133:1-7. [DOI: 10.1016/j.ejps.2019.03.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2018] [Revised: 02/28/2019] [Accepted: 03/10/2019] [Indexed: 10/27/2022]
|
15
|
Schwerk B, Harder L, Windhövel C, Hewicker-Trautwein M, Wagner A, Bach JP, Voigt LC, Hinze U, Chichkov B, Haferkamp H, Lubatschowski H, Nikolic S, Nolte I. Comparison of two prototypes of a magnetically adjustable glaucoma implant in rabbits. PLoS One 2019; 14:e0215316. [PMID: 30973952 PMCID: PMC6459522 DOI: 10.1371/journal.pone.0215316] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Accepted: 03/30/2019] [Indexed: 01/03/2023] Open
Abstract
Glaucoma drainage devices are used in surgical glaucoma therapy. Success of controlling the intraocular pressure is limited due to fibrous implant encapsulation and fibrin coating on the implant which lead to drainage obstructions. An innovative implant with a magnetically adjustable valve was developed. The valve opening of the implant should eliminate inflammatory products from the outflow area and affect fibrous tissue formation to achieve a sufficient long-term aqueous humour outflow. Lifting of this valve should disturb cell adhesion by exerting mechanical forces. Before testing this hypothesis, the flow characteristics of glaucoma drainage devices, especially the outflow resistance by regular IOP, should be considered in a pilot study, as they are important in preventing too low postoperative intraocular pressure known as ocular hypotony. Therefore, two prototypes of the innovative implant differing in their valve area design were examined regarding their flow characteristics in a limited animal experiment lasting two weeks. Ten healthy New Zealand White rabbits were divided into two groups (A & B) with different implanted prototypes. Daily, tonometry and direct ophthalmoscopy were performed to assess the intraocular pressure and the inflammatory reaction of the eye. After two weeks, the rabbits were euthanised to evaluate the initially histological inflammatory reaction to the implant. In group A, one case of hypotony emerged. When considering the entire observation period, a highly statistically significant difference between the intraocular pressure in the operated eye and that in the control eye was detected in group A (p < 0.0001) in contrast to group B (p = 0.0063). The postoperative inflammatory signs decreased within two weeks. Histologically, a typical but low level foreign body reaction with macrophages and lymphocytes as well as mild to moderate fibrosis was seen after the short experimental period. Based on our tonometric results, prototype B seems to be the system of choice for further research assessing its long-term function and biocompatibility.
Collapse
Affiliation(s)
- Birthe Schwerk
- Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany
- * E-mail: (IN); (BS)
| | - Lisa Harder
- Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany
| | - Claudia Windhövel
- Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany
| | | | - Anna Wagner
- Institute for Pathology, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany
| | - Jan-Peter Bach
- Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany
| | - Lena Carolin Voigt
- Clinic for Small Mammals, Reptiles and Birds, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany
| | - Ulf Hinze
- Institute of Quantum Optics, Gottfried Wilhelm Leibniz University Hannover, Hannover, Germany
| | - Boris Chichkov
- Institute of Quantum Optics, Gottfried Wilhelm Leibniz University Hannover, Hannover, Germany
| | - Heinz Haferkamp
- Gottfried Wilhelm Leibniz University Hannover, Hannover, Germany
| | | | | | - Ingo Nolte
- Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany
- * E-mail: (IN); (BS)
| |
Collapse
|
16
|
Tekin K, Inanc M, Elgin U. Monitoring and management of the patient with pseudoexfoliation syndrome: current perspectives. Clin Ophthalmol 2019; 13:453-464. [PMID: 30880906 PMCID: PMC6402616 DOI: 10.2147/opth.s181444] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Pseudoexfoliation syndrome (PES) is a complex and age-related systemic disorder characterized by the progressive accumulation and granular deposition of pseudoexfoliative material in various intraocular and extraocular tissues. The diagnosis of PES is so important because it is a major risk factor for complications during cataract surgery and the most frequent cause of secondary glaucoma. In addition to ocular complications, PES is related with numerous systemic abnormalities, for which the list is growing steadily. Therefore, management and monitoring of patients with PES are crucial. The aim of this paper was to review current perspectives on monitoring patients with PES and addressing management of ocular and systemic associations of this clinically important and biologically fascinating disease.
Collapse
Affiliation(s)
- Kemal Tekin
- Ophthalmology Department, Erciş State Hospital, Erciş, Van, Turkey,
| | - Merve Inanc
- Ophthalmology Department, Erciş State Hospital, Erciş, Van, Turkey,
| | - Ufuk Elgin
- Ophthalmology Department, Ulucanlar Eye Training and Research Hospital, University of Health Sciences, Ankara, Turkey
| |
Collapse
|