1
|
Dalsasso LCF, Marchioni C. Post-mortem toxicological analysis of cocaine: main biological samples and analytical methods. Forensic Sci Med Pathol 2024; 20:1091-1101. [PMID: 37553490 DOI: 10.1007/s12024-023-00678-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/12/2023] [Indexed: 08/10/2023]
Abstract
This scoping review intends to identify the most used analytical methods and biological samples in the post-mortem forensic toxicological analysis of cocaine and its metabolites. A scoping review was performed based on the question "What are the analytical methods and types of biological samples most frequently used to identify and quantify cocaine in post-mortem forensic toxicology?" The studies were selected from five databases and, after exclusions, the data were tabulated, analyzed, and reported. Twenty-one articles published between 2012 and 2022 were filtered from five different databases to be studied. The collected data indicate that the most used biological samples were blood and hair. The most used sample preparation technique was solid phase extraction, while the most mentioned chromatography method was liquid chromatography with mass spectrometry. This review presents and discusses the state of the art regarding methods for the detection sensitivity spectrum, why limits of quantification are so important for these methods, and what are the most suitable biological samples to be utilized in each case. Cocaine and metabolites are important in forensic toxicologic post-mortem analysis. However, there is little concern in the development of miniaturized and automated sample preparation in this field. Besides, there is not enough understanding of post-mortem redistribution, tolerance, drug-drug interactions, and pre-existing medical conditions.
Collapse
Affiliation(s)
| | - Camila Marchioni
- Department of Pathology, Federal University of Santa Catarina, St. Delfino Conti S/N, Florianopolis, SC, 88040-370, Brazil.
| |
Collapse
|
2
|
Makhdoom HS, Afzal S, Sultana K, Shah SNH, Mujahid M, Hassan ZU, Munir F, Jahan F, Abbas Z, Abid AI, Khan NUH. SPE-UHPLC-ESI-MS/MS Analysis of Cocaine and Its Metabolites in Conventional and Alternative Biological Specimens: Application to Real Samples. ACS OMEGA 2024; 9:23355-23363. [PMID: 38854579 PMCID: PMC11154955 DOI: 10.1021/acsomega.3c09669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 03/26/2024] [Accepted: 05/15/2024] [Indexed: 06/11/2024]
Abstract
An increase in cocaine abuse has been observed globally since the past decade. Cocaine is among the commonly abused stimulants used for recreational purposes. In this study, the SPE-UHPLC-MS/MS method was developed and validated to be applied on real specimens of 20 chronic cocaine abusers to quantify cocaine/metabolites in conventional as well as alternative biological matrices. Cocaine was extracted from biological specimens using solid-phase extraction followed by liquid chromatography tandem mass spectrometry analysis. Chromatographic separation was achieved on a Poroshell120EC-18 column (2.1 mm × 50 mm, 2.7 μm particle size) using water-acetonitrile in 0.1% formic acid as a mobile phase in gradient elution mode. The flow rate of the mobile phase was 0.5 mL/min with a gradient varying the percentage of acetonitrile linearity ranging 15-95% in 6.0 min acquisition time, and the injection volume was set at 5 μL. Positive electrospray ionization with multireaction ion monitoring mode using two ion transitions for cocaine/metabolites and one for cocaine-d3 was employed. The quantification method demonstrated good linear ranges of 0.025-250 ng/mL in blood, urine, and oral fluid (ng/mg for hair and nail) with a ≥0.991% determination coefficient. The detection limit and lower quantification limit were 0.005 and 0.025 ng/mL in all matrices, respectively. The mean extraction recovery and ionization suppression ranged from 89.3 to 99.8% and -4.6 to -14.4% in the studied matrices. Within-run and between-days precisions were 1.8-7.2% and 1.9-6.1%, respectively. This study will not only help in quantifying cocaine/metabolites in alternative specimens (hair, nail, and oral fluid) but also guide clinical and forensic toxicologists in interpretation of exhumation cases. Furthermore, multiple specimens' analyses can be of significance in estimating the time/manner of drug exposure, in confirming the results of laboratories in cases of doubtful clinical histories, or in aiding medico-legal investigations.
Collapse
Affiliation(s)
- Humera Shafi Makhdoom
- Faculty of Pharmacy, University of Lahore, Lahore 44000, Pakistan
- Clinical
and Forensic Toxicology Department, Chughtai
Healthcare, Lahore 54000, Pakistan
| | - Saira Afzal
- Faculty of Pharmacy, University of Lahore, Lahore 44000, Pakistan
| | - Kishwar Sultana
- Department of Pharmacy, Iqra
University Islamabad Campus, Islamabad 440000, Pakistan
| | | | - Majida Mujahid
- Faculty of Pharmacy, University of Lahore, Lahore 44000, Pakistan
- Drug
Regulatory Authority of Pakistan, Lahore 54000, Pakistan
| | | | - Farida Munir
- Faculty of Pharmacy, University of Lahore, Lahore 44000, Pakistan
| | - Faryal Jahan
- Shifa Tameer e Millat University Islamabad, Islamabad 44000, Pakistan
| | - Zeerak Abbas
- Clinical
and Forensic Toxicology Department, Chughtai
Healthcare, Lahore 54000, Pakistan
| | - Ali Imran Abid
- Department of Regenerative
Nanomedicine, University of Strasbourg, Strasbourg 67081, France
| | | |
Collapse
|
3
|
Song Y, Zhang Y, Wang L, Hu C, Liu ZF, Feng XS, He ZW. Cocaine in Different Matrices: Recent Updates on Pretreatment and Detection Techniques. Crit Rev Anal Chem 2022; 54:529-548. [PMID: 35708993 DOI: 10.1080/10408347.2022.2087467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Cocaine abuse has attracted increased attention in the recent past since it can cause addiction and great harm to the normal human body. Due to cocaine exists in various complex matrices, the detection of it in different matrices is helpful to prevent abuse. It is thus imperative to establish efficient and accurate methods for pretreatment and detection of cocaine in different samples. The present study provides a summary of the research progress of cocaine pretreatment methods (such as different microextraction methods, QuEChERS, and solid phase extraction based on novel extraction materials) and detection approaches (such as liquid chromatography coupled with different detectors, gas chromatography and related techniques, capillary electrophoresis and sensors). A comparison of the pros and cons of different pretreatment and detection methods is presented. The findings of this study will provide a reference for selection of the most suitable cocaine pretreatment and detection techniques.
Collapse
Affiliation(s)
- Yang Song
- School of Pharmacy, China Medical University, Shenyang, China
| | - Yuan Zhang
- School of Pharmacy, China Medical University, Shenyang, China
| | - Ling Wang
- Department of Pharmacy, Xiangya Hospital, Central South University, Changsha, China
| | - Cong Hu
- School of Pharmacy, China Medical University, Shenyang, China
| | - Zhi-Fei Liu
- School of Pharmacy, China Medical University, Shenyang, China
| | - Xue-Song Feng
- School of Pharmacy, China Medical University, Shenyang, China
| | - Zhen-Wei He
- Department of Neurology, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
| |
Collapse
|
4
|
Blood and Plasma Volumetric Absorptive Microsampling (VAMS) Coupled to LC-MS/MS for the Forensic Assessment of Cocaine Consumption. Molecules 2020; 25:molecules25051046. [PMID: 32110941 PMCID: PMC7179185 DOI: 10.3390/molecules25051046] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 02/10/2020] [Accepted: 02/24/2020] [Indexed: 02/01/2023] Open
Abstract
Reliable, feasible analytical methods are needed for forensic and anti-doping testing of cocaine and its most important metabolites, benzoylecgonine, ecgonine methyl ester, and cocaethylene (the active metabolite formed in the presence of ethanol). An innovative workflow is presented here, using minute amounts of dried blood or plasma obtained by volumetric absorptive microsampling (VAMS), followed by miniaturized pretreatment by dispersive pipette extraction (DPX) and LC-MS/MS analysis. After sampling 20 µL of blood or plasma with a VAMS device, the sample was dried, extracted, and loaded onto a DPX tip. The DPX pretreatment lasted less than one minute and after elution with methanol the sample was directly injected into the LC-MS/MS system. The chromatographic analysis was carried out on a C8 column, using a mobile phase containing aqueous formic acid and acetonitrile. Good extraction yield (> 85%), precision (relative standard deviation, RSD < 6.0%) and matrix effect (< 12%) values were obtained. Analyte stability was outstanding (recovery > 85% after 2 months at room temperature). The method was successfully applied to real blood and plasma VAMS, with results in very good agreement with those of fluid samples. The method seems suitable for the monitoring of concomitant cocaine and ethanol use by means of plasma or blood VAMS testing.
Collapse
|
5
|
25-Hydroxyvitamin D Measurement in Human Hair: Results from a Proof-of-Concept study. Nutrients 2019; 11:nu11020423. [PMID: 30781610 PMCID: PMC6412768 DOI: 10.3390/nu11020423] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Revised: 02/03/2019] [Accepted: 02/14/2019] [Indexed: 12/27/2022] Open
Abstract
Vitamin D deficiency has been implicated in numerous human diseases leading to an increased interest in assessing vitamin D status. Consequentially, the number of requests for vitamin D measurement keeps dramatically increasing year-on-year. Currently, the recognised best marker of vitamin D status is the concentration of the 25-hydroxyvitamin D (25(OH)D3) in the blood circulation. While providing an accurate estimate of vitamin D status at the point in time of sampling, it cannot account for the high variability of 25(OH)D3 concentration. In this proof of concept study we set out to provide evidence that 25(OH)D3 can be extracted from hair samples in a similar fashion to steroid hormones. Two of the authors (L.Z. and M.H.) provided hair samples harvested from the crown area of the scalp and the third author (E.L.) provided beard samples. These samples, cut into 1 cm lengths, were weighed, washed and dried. 25(OH)D was extracted using a previously published steroid hormones extraction procedure. Blood samples were taken from the subjects at the same time all tissue samples were analysed using liquid-chromatography mass spectrometry. Hair samples showed presence of quantifiable 25(OH)D3 with concentrations ranging from 11.9–911 pg/mg. The beard sample had a concentration of 231 pg/mg. Serum levels of 25(OH)D3 ranged from 72–78 nmol/L. The results presented here confirm the feasibility of measuring 25(OH)D3 in hair samples. The findings warrant further validation and development and have the potential to yield valuable information relating to temporal trends in vitamin D physiology.
Collapse
|
6
|
Ambach L, Menzies E, Parkin MC, Kicman A, Archer JR, Wood DM, Dargan PI, Stove C. Quantification of cocaine and cocaine metabolites in dried blood spots from a controlled administration study using liquid chromatography–tandem mass spectrometry. Drug Test Anal 2018; 11:709-720. [DOI: 10.1002/dta.2537] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 10/25/2018] [Accepted: 10/26/2018] [Indexed: 01/17/2023]
Affiliation(s)
- Lars Ambach
- Faculty of Pharmaceutical Sciences, Department of Bioanalysis, Laboratory of ToxicologyGhent University Ottergemsesteenweg 460 9000 Ghent Belgium
| | - Eleanor Menzies
- School of Population Health & Environmental Sciences Drug Control CentreKing's College London London UK
| | - Mark C. Parkin
- School of Population Health & Environmental Sciences Drug Control CentreKing's College London London UK
| | - Andrew Kicman
- School of Population Health & Environmental Sciences Drug Control CentreKing's College London London UK
| | - John R.H. Archer
- Clinical ToxicologyGuy's and St. Thomas' NHS Foundation Trust London UK
- Faculty of Life Sciences and MedicineKing's College London London UK
| | - David M. Wood
- Clinical ToxicologyGuy's and St. Thomas' NHS Foundation Trust London UK
- Faculty of Life Sciences and MedicineKing's College London London UK
| | - Paul I. Dargan
- Clinical ToxicologyGuy's and St. Thomas' NHS Foundation Trust London UK
| | - Christophe Stove
- Faculty of Pharmaceutical Sciences, Department of Bioanalysis, Laboratory of ToxicologyGhent University Ottergemsesteenweg 460 9000 Ghent Belgium
| |
Collapse
|
7
|
Takitane J, Leyton V, Andreuccetti G, Gjerde H, Vindenes V, Berg T. Determination of cocaine, metabolites and a crack cocaine biomarker in whole blood by liquid–liquid extraction and UHPLC–MS/MS. Forensic Sci Int 2018; 289:165-174. [DOI: 10.1016/j.forsciint.2018.05.030] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Revised: 05/04/2018] [Accepted: 05/19/2018] [Indexed: 11/17/2022]
|
8
|
Chantada–Vázquez MP, de–Becerra–Sánchez C, Fernández–del–Río A, Sánchez–González J, Bermejo AM, Bermejo–Barrera P, Moreda–Piñeiro A. Development and application of molecularly imprinted polymer – Mn-doped ZnS quantum dot fluorescent optosensing for cocaine screening in oral fluid and serum. Talanta 2018; 181:232-238. [DOI: 10.1016/j.talanta.2018.01.017] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 01/04/2018] [Accepted: 01/07/2018] [Indexed: 11/17/2022]
|
9
|
Li GZ, Tang D. Bioresponsive controlled glucose release from TiO2 nanotube arrays: a simple and portable biosensing system for cocaine with a glucometer readout. J Mater Chem B 2017. [DOI: 10.1039/c7tb00670e] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Herein, we design a simple and portable biosensing platform for the quantitative detection of cocaine based on target-triggered glucose release from a TiO2 nanotube array (TiNTA) with a glucometer readout.
Collapse
Affiliation(s)
- Guang-Zhou Li
- Department of Sports and Health
- Chongqing Three Gorges University
- Wanzhou 404100
- China
- Key Laboratory of Analysis and Detection for Food Safety (MOE & Fujian Province)
| | - Dianping Tang
- Key Laboratory of Analysis and Detection for Food Safety (MOE & Fujian Province)
- Collaborative Innovation Center of Detection Technology for Haixi Food Safety and Products (Fujian Province)
- State Key Laboratory of Photocatalysis on Energy and Environment
- Department of Chemistry
- Fuzhou University
| |
Collapse
|