1
|
Yenamandra MS, Joseph A, Singh P, Venkitachalam R, Maya R, Presannakumar G. Effect of Various Surface Treatments of Zirconia on its Adhesive Properties to Dentin: An In Vitro Study. J Contemp Dent Pract 2024; 25:226-230. [PMID: 38690694 DOI: 10.5005/jp-journals-10024-3663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
AIM To assess the effectiveness of various surface treatments and adhesives on the bond strength of zirconia-based ceramic to dentin. MATERIALS AND METHODS Eighty samples of zirconia were subjected to the four-surface treatment protocols (sandblasting, 48% hydrofluoric acid (HF), 48% hydrofluoric acid + 70% nitric acid (HNO3) and no treatment (control) following which the samples from each group were subdivided into two subgroups (n = 10) based on the resin cement employed for cementation (RelyX U200 and G-Cem Linkforce). The bonded specimens were subjected to shear stress to measure the bond strength using Universal testing machine. To test the difference in bond strength among the eight study groups, the Kruskal-Wallis ANOVA test was applied and for comparison between cements in each group, Mann-Whitney U test was applied. RESULTS The highest bond strength values were observed for 48% HF group cemented with G-Cem Linkforce resin cement (16.220 ± 1.574) and lowest for control group-RelyX (4.954 ± 0.972). G-Cem cement showed higher bond strength than RelyX for all surface treatments except 48% HF + 70% nitric acid. CONCLUSION It can be inferred that 48% HF can etch zirconia and generate a porous structure that proves to be beneficial for bonding. CLINICAL SIGNIFICANCE The increasing demand for esthetics has led to the replacement of metal-ceramic materials with zirconia-based ceramics. However, the chemical inertness of zirconia to various conventional surface treating agents has continuously challenged researchers to discover a new surface treatment protocol that could enhance the bond strength of zirconia. How to cite this article: Yenamandra MS, Joseph A, Singh P, et al. Effect of Various Surface Treatments of Zirconia on its Adhesive Properties to Dentin: An In Vitro Study. J Contemp Dent Pract 2024;25(3):226-230.
Collapse
Affiliation(s)
- Manasvi S Yenamandra
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India, Orcid: https://orcid.org/0000-0002-5097-0019
| | - Asha Joseph
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India, Phone: +91 9746473521, e-mail: , Orcid: https://orcid.org/0000-0001-7067-1529
| | - Prabath Singh
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India, Orcid: https://orcid.org/0000-0003-1960-4886
| | - Ramanarayanan Venkitachalam
- Department of Public Health Dentistry, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India, Orcid: https://orcid.org/0000-0002-5587-3453
| | - Remya Maya
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India, Orcid: https://orcid.org/0000-0003-3528-8537
| | - Gayathri Presannakumar
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India, Orcid: https://orcid.org/0000-0001-7400-6702
| |
Collapse
|
2
|
Dghaily D, Rayyan M, Ragab H, Sayed M, Ayash G, Alzahrani G. Comparison of Fracture Resistance between Different Treatment Modalities of Mutilated Endodontically Treated Teeth Using Polyether Ether Ketone. J Contemp Dent Pract 2023; 24:668-673. [PMID: 38152940 DOI: 10.5005/jp-journals-10024-3558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2023]
Abstract
AIM To compare fracture resistance of multiple treatment modalities intended for mutilated teeth using polyether ether ketone (PEEK) and zirconia materials. MATERIALS AND METHODS The study was divided into four groups according to treatment modality adopted (n = 14): fiber post (F), Nayyar core (N), endocrown (E), and Richmond crown (R). Each group was further subdivided into two groups (n = 7) according to the type of material used: zirconia (Z) and PEEK (P). Using computer-aided design/computer-aided manufacturing, restorations were constructed from both materials following tested treatment options and manufacturer direction. Finished restorations were then tried, seated, and cemented to their corresponding acrylic teeth. All specimens were tested for fracture resistance in universal testing machine with cross head speed of 0.5 mm/min speed until failure, which was confirmed by a sudden drop in the measurements of the testing machine. Results were recorded, tabulated, and statistically analyzed. Shapiro-Wilk normality tests were considered to evaluate the normality of the data distributions. One-way analysis of variance (ANOVA) followed by Tukey's post hoc analysis was conducted to analyze the fracture resistance significant differences. RESULTS Descriptive statistics of the restoration material revealed statistically a higher mean value for PEEK material (3609 ± 188.1) than zirconia (2404 ± 425.6). One-way ANOVA revealed statistically significant differences between zirconia group (p < 0.0001). Regarding zirconia group statistical significance was detected between fiber post vs endocrown (p = 0.0299), fiber post vs Richmond crown (p < 0.0001), and Nayyar core vs Richmond crown (p = 0.0004). However, there was no statistically significant difference between PEEK group (P = 0.1614). CONCLUSION Polyether ether ketone could present a reliable treatment option in endodontically treated teeth. CLINICAL SIGNIFICANCE Using one-piece Richmond crowns constructed of PEEK could present a viable treatment option against conventional treatment options of root canal treatment (RCT) single-rooted teeth.
Collapse
Affiliation(s)
- Diana Dghaily
- Department of Oral Rehabilitation Sciences, Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| | - Mohammad Rayyan
- Department of Fixed Prosthodontics, Faculty of Dentistry, Sinai University, Kantara Campus, Sinai, Egypt
| | - Hala Ragab
- Department of Restorative Sciences, Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| | - Mohamed Sayed
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ahram Canadian University, Egypt, Phone: +20 1288670943, e-mail:
| | - Ghada Ayash
- Department of Oral Rehabilitation Sciences, Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| | - Ghadah Alzahrani
- Department of Oral Rehabilitation Sciences, Faculty of Dentistry, Beirut Arab University, Beirut, Lebanon
| |
Collapse
|
3
|
Prott LS, Spitznagel FA, Bonfante EA, Malassa MA, Gierthmuehlen PC. Monolithic zirconia crowns: effect of thickness reduction on fatigue behavior and failure load. J Adv Prosthodont 2021; 13:269-280. [PMID: 34777717 PMCID: PMC8558575 DOI: 10.4047/jap.2021.13.5.269] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 08/30/2021] [Accepted: 09/14/2021] [Indexed: 11/23/2022] Open
Abstract
PURPOSE The objective of this study was to evaluate the effect of thickness reduction and fatigue on the failure load of monolithic zirconia crowns. MATERIALS AND METHODS 140 CAD-CAM fabricated crowns (3Y-TZP, inCorisTZI, Dentsply-Sirona) with different ceramic thicknesses (2.0, 1.5, 1.0, 0.8, 0.5 mm, respectively, named G2, G1.5, G1, G0.8, and G0.5) were investigated. Dies of a mandibular first molar were made of composite resin. The zirconia crowns were luted with a resin composite cement (RelyX Unicem 2 Automix, 3M ESPE). Half of the specimens (n = 14 per group) were mouth-motion-fatigued (1.2 million cycles, 1.6 Hz, 200 N/ 5 – 55℃, groups named G2-F, G1.5-F, G1-F, G0.8-F, and G0.5-F). Single-load to failure was performed using a universal testing-machine. Fracture modes were analyzed. Data were statistically analyzed using a Weibull 2-parameter distribution (90% CI) to determine the characteristic strength and Weibull modulus differences among the groups. RESULTS Three crowns (21%) of G0.8 and five crowns (36%) of G0.5 showed cracks after fatigue. Characteristic strength was the highest for G2, followed by G1.5. Intermediate values were observed for G1 and G1-F, followed by significantly lower values for G0.8, G0.8-F, and G0.5, and the lowest for G0.5-F. Weibull modulus was the lowest for G0.8, intermediate for G0.8-F and G0.5, and significantly higher for the remaining groups. Fatigue only affected G0.5-F. CONCLUSION Reduced crown thickness lead to reduced characteristic strength, even under failure loads that exceed physiological chewing forces. Fatigue significantly reduced the failure load of 0.5 mm monolithic 3Y-TZP crowns.
Collapse
Affiliation(s)
- Lea Sophia Prott
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany
| | - Frank Akito Spitznagel
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany
| | - Estevam Augusto Bonfante
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of Sao Paulo, Bauru, SP, Brazil
| | | | - Petra Christine Gierthmuehlen
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany
| |
Collapse
|
4
|
Comparison of Mechanical Properties of Chairside CAD/CAM Restorations Fabricated Using a Standardization Method. MATERIALS 2021; 14:ma14113115. [PMID: 34204092 PMCID: PMC8200951 DOI: 10.3390/ma14113115] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 06/02/2021] [Accepted: 06/03/2021] [Indexed: 11/18/2022]
Abstract
The aim of this in vitro study was to investigate the fracture resistance, fracture failure pattern, and fractography of four types of chairside computer-aided design/computer-aided manufacturing (CAD/CAM) restoration materials in teeth and titanium abutments fabricated using a standardization method. An artificial mandibular left first premolar prepared for all-ceramic crown restoration was scanned. Forty extracted mandibular molars and cylindrical titanium specimens were milled into a standardized shape. A total of eighty CAD/CAM restoration blocks were milled into a crown and twenty pieces of each lithium disilicate (LS), polymer-infiltrated-ceramic-network (PICN), resin nano ceramic (RNC), and zirconia-reinforced lithium silicate (ZLS) materials were used. Crowns were bonded to abutments, and all specimens underwent thermal cycling treatment for 10,000 cycles. Fracture resistance was measured using a universal testing machine and fracture failure patterns were analyzed using optical microscopy and scanning electron microscopy. Statistical differences were analyzed using appropriate ANOVA, Tukey HSD post hoc tests, and independent sample t-tests (α = 0.05). The results indicated that, in both teeth abutments and titanium abutments, the fracture resistances showed significantly the highest values in LS and the second highest in ZLS (p < 0.05). The fracture resistances based on teeth abutments and titanium abutments were significantly different in all the CAD/CAM restoration materials (p < 0.05). There are statistically significant correlations between the types of materials and the types of abutments (p < 0.05). Each of the different materials showed different fracture failure patterns, and there was no noticeable difference in fractographic analysis. Lithium disilicates and zirconia-reinforced lithium silicates exhibited statistically high fracture resistance, indicating their suitability as restoration materials for natural teeth or implant abutments. There were no distinct differences in the fracture pattern based on the restoration and abutment materials showed that the fracture initiated at the groove where the ball indenter was toughed and propagated toward the axial wall.
Collapse
|
5
|
Harb O, Al-Zordk W, Özcan M, Sakrana AA. Influence of Hydrofluoric and Nitric Acid Pre-Treatment and Type of Adhesive Cement on Retention of Zirconia Crowns. MATERIALS 2021; 14:ma14040960. [PMID: 33670574 PMCID: PMC7923146 DOI: 10.3390/ma14040960] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 02/09/2021] [Accepted: 02/15/2021] [Indexed: 11/16/2022]
Abstract
Background: The aim of this study was to test the impact of hot acids etching and two types of adhesive cement on the retention of zirconia crowns. Methods: Forty maxillary premolars were prepared, and zirconia crowns were designed and fabricated with proximal extensions, then divided into 4 groups (n = 10). Group AP; the crowns were air-abraded and cemented using Panavia SA Cement. Group AL; the crowns were air- abraded and cemented using GC LinkForce. Group AHP; the crowns were air-abraded, etched with the hot acids (48% hydrofluoric acid and 69% nitric acid), and cemented using Panavia SA Cement. Group AHL; the crowns were air-abraded, etched with the hot acids, and cemented using GC LinkForce. Each zirconia crown was pre-treated and bonded to its corresponding tooth. After thermocycling (5–55 °C/10,000), the retention test was performed and the load required to dislodge the crown was reported in Newton (N), and mode of failure was recorded. The retention strength (MPa) was calculated for each tested variable and statistically analyzed. Results: Group AHP showed the highest mean value of the retention strength, followed by group AP then group AHL. Group AL showed the lowest value. A statistically significant effect (p = 0.001) of the hot acids etching on the retention of zirconia crown was found. Also, there was a significant effect (p = 0.000) of the cement type. The interaction between surface treatment and the cement type has no significant impact (p = 0.882). The main mode of failure for Panavia SA Cement is mixed mode of failure, while for G-CEM LinkForce is adhesive failure. Conclusions: Hot acid etching pre-treatment improved the retention of zirconia crown. Usage of Panavia SA Cement with hot acids etching is effective can be used for adhesive cementation of zirconia crown.
Collapse
Affiliation(s)
- Osama Harb
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura and Horus University, Mansoura 35511, Egypt; (O.H.); (W.A.-Z.)
| | - Walid Al-Zordk
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura and Horus University, Mansoura 35511, Egypt; (O.H.); (W.A.-Z.)
| | - Mutlu Özcan
- Center for Dental and Oral Medicine, Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, University of Zurich, 8032 Zurich, Switzerland;
| | - Amal Abdelsamad Sakrana
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura and Horus University, Mansoura 35511, Egypt; (O.H.); (W.A.-Z.)
- Correspondence: ; Tel.: +2-010-238-49099
| |
Collapse
|
6
|
Fracture Load of CAD/CAM Feldspathic Crowns Influenced by Abutment Material. MATERIALS 2020; 13:ma13153407. [PMID: 32748827 PMCID: PMC7435702 DOI: 10.3390/ma13153407] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Revised: 07/22/2020] [Accepted: 07/31/2020] [Indexed: 11/30/2022]
Abstract
In vitro studies investigating the mechanical properties of dental reconstructions use various materials to replicate prepared teeth. However, no uniform recommendation exists as to which material is most suitable for standardized testing. The purpose of this study was to identify a material that resembles human dentin in fracture load tests. Sixteen human teeth were scanned with an intraoral scanner to obtain copies of the original crown morphology and were then prepared for crowns. Replica dies of the prepared teeth including the root morphology were fabricated with a Computer-aided design and computer-aided manufacturing (CAD/CAM) system and divided into four groups: (A) reinforced composite (RC); (B) human dentin (HD); (C) polymethyl methacrylate (PM); and (D) hybrid ceramic (HC). Sixty-four feldspar ceramic crowns were designed with the biocopy mode, fabricated with a CAD/CAM system, luted on the dies, and then with the roots embedded in polymethyl methacrylate. Care was taken to position all specimens of the same morphology identically. Thermo-mechanical load cycling was performed in a chewing simulator followed by fractural loading of the crowns. A mixed effect linear model was fitted to the data, and pairwise contrasts were estimated on the marginal means and corrected for multiple testing according to Tukey (α = 0.05). The means for fracture load (N) were 2435 N (95% CI (2162, 2709)) for hybrid ceramic, 1838 N (95% CI (1565, 2112)) for reinforced composite, 1670 N (95% CI (1396, 1943)) for human tooth and 1142 N (95% CI (868, 1415)) for polymethyl methacrylate abutment materials. Post-hoc pairwise contrasts revealed a statistically significant (p < 0.05) difference among all groups except for reinforced composite and human dentin (p = 0.76). The results indicate that the mechanical properties of abutment dies play a significant role for a possible substitution of natural teeth in in vitro studies.
Collapse
|