Rohr N, Karakas-Stupar I, Karlin S, Zitzmann NU, Zaugg LK. Effect of implant type on the stability of cantilever fixed dental prostheses: An in vitro study. Clin Oral Implants Res 2024; 35:419-426. [PMID: 38329172 DOI: 10.1111/clr.14240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 11/30/2023] [Accepted: 01/11/2024] [Indexed: 02/09/2024]
Abstract
OBJECTIVES To simulate the replacement of a premolar with an implant-supported cantilever fixed dental prosthesis (ICFDP) and how the fracture load is affected by implant type, positioning within the zirconia blank, and aging protocol. MATERIALS AND METHODS Seventy-two ICFDPs were designed either within the enamel- or dentin layer of a 4Y-PSZ blank for bone-level and tissue-level titanium-zirconium implants. Fracture load was obtained on the cantilever at baseline (no aging) or after aging in a chewing simulator with the load applied within the implant axis (axial aging) or on the cantilever (12 groups with n = 6). A three-way ANOVA was applied (α = .05). RESULTS A three-way ANOVA revealed a significant effect on fracture load values of implant type (p = .006) and aging (p < .001) but not for the position within the zirconia blank (p = .847). Fracture load values significantly increased from baseline bone level (608 ± 118 N) and tissue level (880 ± 293 N) when the implants were aged axially, with higher values for tissue level (1065 ± 182 N) than bone level (797 ± 113 N) (p < .001). However, when the force was applied to the cantilever, fracture load values decreased significantly for tissue-level (493 ± 70 N), while values for bone-level implants remained stable (690 ± 135 N). CONCLUSIONS For ICFDPs, the use of bone-level implants is reasonable as catastrophic failures are likely to be restricted to the restoration, whereas with tissue-level implants, the transmucosal portion of the implant is susceptible to deformation, making repair more difficult.
Collapse
Affiliation(s)
- Nadja Rohr
- Biomaterials and Technology, Department of Research, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| | - Irina Karakas-Stupar
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| | - Sabrina Karlin
- Biomaterials and Technology, Department of Research, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| | - Nicola U Zitzmann
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| | - Lucia K Zaugg
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| |
Collapse
|
2
|
Stoilov M, Boehmer T, Stoilov L, Stark H, Marder M, Enkling N, Kraus D. Influence of Cementation Mode and Ferrule Design on the Fatigue Resistance of Monolithic Zirconia Endocrowns. J Clin Med 2024; 13:1165. [PMID: 38398475 PMCID: PMC10889707 DOI: 10.3390/jcm13041165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 02/13/2024] [Accepted: 02/17/2024] [Indexed: 02/25/2024] Open
Abstract
Background: Classic endocrowns made of dental ceramics are considered a promising alternative to traditional post-endodontic restorations. The use of circular ferrules in endocrowns is a topic of controversial discussion. Therefore, the present study aims to evaluate the effect of ferrule design and cementation mode on the fatigue resistance of zirconia endocrowns. Methods: Eighty human molars were divided into four groups (n = 20): NFC (no-ferrule, conventional cementation), NFA (no-ferrule, adhesive luting), FC (ferrule, conventional cementation) and FA (ferrule, adhesive luting). Both the classic and the modified endocrown preparation with a two-millimeter ferrule design were carried out. Endocrowns were fabricated from zirconia using the CEREC system. After thermocycling, specimens were loaded according to the step-stress test up to 1500 N. Results: Failure rate was low; 88.8% of total specimens passed the step-stress test. Fractures were distributed between all groups; no significant differences in fatigue resistance were detected for preparation design and cementation mode. Conclusions: Endocrowns appear to be a promising concept for endodontically treated molars. Ferrule and also cementation mode have only a minor influence on fatigue resistance of zirconia endocrowns. However, at very high forces, the marginal area of the ferrule represents a weak point.
Collapse
Affiliation(s)
- Milan Stoilov
- Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany; (T.B.); (L.S.); (H.S.); (M.M.); (N.E.); (D.K.)
| | - Tobias Boehmer
- Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany; (T.B.); (L.S.); (H.S.); (M.M.); (N.E.); (D.K.)
| | - Lea Stoilov
- Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany; (T.B.); (L.S.); (H.S.); (M.M.); (N.E.); (D.K.)
| | - Helmut Stark
- Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany; (T.B.); (L.S.); (H.S.); (M.M.); (N.E.); (D.K.)
| | - Michael Marder
- Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany; (T.B.); (L.S.); (H.S.); (M.M.); (N.E.); (D.K.)
| | - Norbert Enkling
- Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany; (T.B.); (L.S.); (H.S.); (M.M.); (N.E.); (D.K.)
- Department of Reconstructive Dentistry and Gerodontology, Bern University, 3012 Bern, Switzerland
| | - Dominik Kraus
- Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany; (T.B.); (L.S.); (H.S.); (M.M.); (N.E.); (D.K.)
| |
Collapse
|
3
|
Klotz AL, Halfmann J, Rues S, Bömicke W, Rammelsberg P, Zenthöfer A. Fracture Resistance of Posterior Tooth-Supported Cantilever Fixed Dental Prostheses of Different Zirconia Generations and Framework Thicknesses: An In Vitro Study. Materials (Basel) 2024; 17:263. [PMID: 38204115 PMCID: PMC10779861 DOI: 10.3390/ma17010263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 12/20/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024]
Abstract
The rehabilitation of free-end situations is a frequent indication in prosthetic dentistry. Cantilever fixed dental prostheses (cFDPs) made of 1st and 2nd generation zirconia are one treatment option. Due to a unique gradient technology, combinations of different zirconium dioxide generations are thus feasible in one restoration. However, data about these materials are rare. The purpose of this study was therefore to investigate the fracture resistance and fracture modes of tooth-supported cFDPs fabricated from different zirconia materials (gradient technology) and different framework thicknesses. A total of 40 cFDPs were fabricated using the CAD/CAM approach and belonged to five test groups. The different groups differed in the yttria content, the proportion of the tetragonal/cubic phases, or in wall thickness (0.7 mm or 1 mm). After completion, the cFDPs were subjected to thermal cycling and chewing simulation (1.2 × 106 load cycles, 108 N load). Afterwards, cFDPs were statically loaded until fracture in a universal testing machine. A non-parametric ANOVA was compiled to determine the possible effects of group membership on fracture resistance. In addition, post-hoc Tukey tests were used for bivariate comparisons. The mean fracture loads under axial load application ranged from 288 to 577 N. ANOVA detected a significant impact of the used material on the fracture resistances (p < 0.001). Therefore, the use of cFDPs fabricated by gradient technology zirconia may not be unreservedly recommended for clinical use, whereas cFPDs made from 3Y-TZP exhibit fracture resistance above possible masticatory loads in the posterior region.
Collapse
Affiliation(s)
- Anna-Luisa Klotz
- Department of Prosthodontics, Dental School, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; (J.H.); (S.R.); (W.B.); (P.R.); (A.Z.)
| | | | | | | | | | | |
Collapse
|
4
|
Karasan D, Pitta J, Zarauz C, Strasding M, Liu X, Fehmer V, Sailer I. The influence of titanium-base abutment geometry and height on mechanical stability of implant-supported single crowns. Clin Oral Implants Res 2023. [PMID: 37929698 DOI: 10.1111/clr.14207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 10/22/2023] [Accepted: 11/01/2023] [Indexed: 11/07/2023]
Abstract
AIM This study aimed to investigate the influence of titanium base (ti-base) abutment macro- and micro-geometry on the mechanical stability of polymer-infiltrated ceramic network (PICN) screw-retained implant-supported single crowns (iSCs). MATERIALS AND METHODS Twelve specimens per group were used, comprising six different implant/ti-base abutment combinations restored with PICN iSCs: Nb-T (gingival height [GH]: 1.5 mm, prosthetic height [PH]: 4.3 mm), CC (GH: 0.8 mm, PH: 4.3 mm), CC-P (GH: 0.8 mm, PH: 7 mm), Nb-V (GH: 1.5 mm, PH: 6 mm), St (GH: 1.5 mm, PH: 5.5 mm), and Th (GH: 0.5 mm, PH: 9 mm). The specimens underwent thermo-mechanical aging, and those that survived were subsequently subjected to static loading until failure. The data were analyzed using a one-way ANOVA test followed by Tukey post hoc test (α = .05). RESULTS All specimens survived thermo-mechanical aging without complications, namely, visible cracks, debonding, or screw loosening. Th group demonstrated the highest strength values among all the groups, with significant differences compared to Nb-T (p < .05), CC (p < .001), and St (p < .001). Additionally, CC-P group exhibited significantly superior fracture strength results compared to CC (p < .05) and St (p < .05). CONCLUSION The choice of ti-base, particularly prosthetic height, had a significant influence on fracture resistance of PICN iSCs. Nevertheless, the height or geometrical features of the ti-base did not exhibit a significant influence on the mechanical behavior of the iSC/ti-base assembly under thermomechanical loading, as all specimens withstood the aging without complication or failure.
Collapse
Affiliation(s)
- Duygu Karasan
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - João Pitta
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Cristina Zarauz
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Malin Strasding
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Xinran Liu
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
- Department of Comprehensive Dentistry, Peking University and Hospital of Stomatology First Clinical Division, Beijing, China
| | - Vincent Fehmer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
5
|
Mangoush E, Garoushi S, Vallittu P, Lassila L. Load-bearing capacity and wear characteristics of short fiber-reinforced composite and glass ceramic fixed partial dentures. Eur J Oral Sci 2023; 131:e12951. [PMID: 37641165 DOI: 10.1111/eos.12951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Accepted: 08/15/2023] [Indexed: 08/31/2023]
Abstract
The aim of this study was to evaluate load-bearing capacity and wear performance of experimental short fiber-reinforced composite (SFRC) and conventional lithium-disilicate CAD/CAM fabricated fixed partial dentures (FPDs). Two groups (n = 12/group) of three-unit CAD/CAM fabricated posterior FPDs were made. The first group used experimental SFRC blocks, and the second group fabricated from lithium-disilicate (IPS e.max CAD). All FPDs were luted on a zirconia testing jig with dual-curing resin cement. Half of FPDs per group were quasi-statically loaded until fracture. The other half experienced cyclic fatigue aging (100.000 cycles, Fmax = 500 N) before loading quasi-statically until fracture. Fracture mode was examined using SEM. Wear test was performed using 15,000 loading cycles. Both material type and aging had a significant effect on the load-bearing capacity of FPDs. Experimental SFRC CAD without fatigue aging had significantly the highest load-bearing capacity (2096 ± 149N). Cyclic fatigue aging decreased the load-bearing capacity of the SFRC group (1709 ± 188N) but increased it for the lithium-disilicate group (1546 ± 155N). Wear depth values of SFRC CAD (29.3μm) were significantly lower compared to lithium-disilicate (54.2μm). Experimental SFRC CAD demonstrated the highest load-bearing capacity before and after cyclic fatigue aging, and superior wear behavior compared to the control material.
Collapse
Affiliation(s)
- Enas Mangoush
- Department of Biomaterials Science and Turku Clinical Biomaterial Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - Sufyan Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterial Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - Pekka Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterial Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland
- Wellbeing Services County of South-West Finland, Turku, Finland
| | - Lippo Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterial Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| |
Collapse
|
6
|
Gil A, Eliades G, Özcan M, Jung RE, Hämmerle CHF, Ioannidis A. Strength of implant-supported lithium disilicate and polymer-infiltrated ceramic network restorations after thermomechanical aging. Int J Comput Dent 2023; 26:237-245. [PMID: 36632986 DOI: 10.3290/j.ijcd.b3781703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
AIM To evaluate the fracture load and type of failure of two different monolithic restorative materials bonded to standardized titanium bases and fabricated by two different procedures regarding the bonding interface. MATERIALS AND METHODS All screw-retained implant crown specimens (n = 40), subjected to fatigue by thermomechanical loading, differed in the restorative material (lithium disilicate [LDS] or polymer-infiltrated ceramic network [PICN], referred to as 'hybrid ceramic' [HYC]) and the interface type between the restorative material and the titanium base abutment (prefabricated ex-factory or produced during a CAM-milling procedure). This resulted in the following groups (n = 10/group): 1) LDS-M: lithium disilicate crown with a CAM-milled interface; 2) LDS-P: lithium disilicate crown with a prefabricated interface; 3) HYC-M: PICN crown with a CAM-milled interface; and 4) HYC-P: PICN crown with a prefabricated interface. Aged specimens underwent static fracture load testing. The load (N) at which the initial crack occurred was denoted as Finitial, and the maximal load (N) at which the restorations fractured as Fmax. All specimens were examined under a stereomicroscope to determine the failure mode. RESULTS The median Finitial values were 180 N for LDS-M, 343 N for LDS-P, 340 N for HYC-M, and 190 N for HYC-P. The median Fmax values were 1822 N for LDS-M, 2039 N for LDS-P, 1454 N for HYC-M, and 1581 N for HYC-P. The intergroup differences were significant for Finitial (KW: P = 0.0042) and for Fmax (KW: P = 0.0010). The failure types also showed differences between the restorative groups. CONCLUSIONS The choice of restorative material had a stronger influence on the fracture load than the abutment interface workflow. Lithium disilicate showed the highest load for initial crack appearance (Finitial) and for complete fracture of the restoration (Fmax).
Collapse
|
7
|
Lu WJ, Chen WC, Srimaneepong V, Chen CS, Huang CH, Lin HC, Tung OH, Huang HH. Fracture Characteristics of Commercial PEEK Dental Crowns: Combining the Effects of Aging Time and TiO 2 Content. Polymers (Basel) 2023; 15:2720. [PMID: 37376366 DOI: 10.3390/polym15122720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 06/16/2023] [Accepted: 06/16/2023] [Indexed: 06/29/2023] Open
Abstract
Polyetheretherketone (PEEK) is an emerging thermoplastic polymer with good mechanical properties and an elastic modulus similar to that of alveolar bone. PEEK dental prostheses for computer-aided design/computer-aided manufacturing (CAD/CAM) systems on the market often have additives of titanium dioxide (TiO2) to strengthen their mechanical properties. However, the effects of combining aging, simulating a long-term intraoral environment, and TiO2 content on the fracture characteristics of PEEK dental prostheses have rarely been investigated. In this study, two types of commercially available PEEK blocks, containing 20% and 30% TiO2, were used to fabricate dental crowns by CAD/CAM systems and were aged for 5 and 10 h based on the ISO 13356 specifications. The compressive fracture load values of PEEK dental crowns were measured using a universal test machine. The morphology and crystallinity of the fracture surface were analyzed by scanning electron microscopy and an X-ray diffractometer, respectively. Statistical analysis was performed using the paired t-test (α = 0.05). Results showed no significant difference in the fracture load value of the test PEEK crowns with 20% and 30% TiO2 after 5 or 10 h of aging treatment; all test PEEK crowns have satisfactory fracture properties for clinical applications. Fracture surface analysis revealed that all test crowns fractured from the lingual side of the occlusal surface, with the fracture extending along the lingual sulcus to the lingual edge, showing a feather shape at the middle part of the fracture extension path and a coral shape at the end of the fracture. Crystalline analysis showed that PEEK crowns, regardless of aging time and TiO2 content, remained predominantly PEEK matrix and rutile phase TiO2. We would conclude that adding 20% or 30% TiO2 to PEEK crowns may have been sufficient to improve the fracture properties of PEEK crowns after 5 or 10 h of aging. Aging times below 10 h may still be safe for reducing the fracture properties of TiO2-containing PEEK crowns.
Collapse
Affiliation(s)
- Wen-Ju Lu
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
| | - Wei-Cheng Chen
- Department of Medicine, MacKay Medical College, New Taipei City 252, Taiwan
- Division of Sports Medicine & Surgery, Department of Orthopedic Surgery, MacKay Memorial Hospital, Taipei 104, Taiwan
| | - Viritpon Srimaneepong
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand
| | - Chiang-Sang Chen
- Department of Orthopedic Surgery, Far Eastern Memorial Hospital, New Taipei City 220, Taiwan
- Department of Materials and Textiles, Asia Eastern University of Science and Technology, New Taipei City 220, Taiwan
| | - Chang-Hung Huang
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Medical Research, MacKay Memorial Hospital, Taipei 251, Taiwan
| | - Hui-Ching Lin
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Stomatology, Taipei City Hospital, Zhongxing Branch, Taipei 103, Taiwan
- General Education Center, University of Taipei, Taipei 106, Taiwan
| | - Oi-Hong Tung
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Stomatology, Taipei Veterans General Hospital, Taipei 112, Taiwan
| | - Her-Hsiung Huang
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Stomatology, Taipei Veterans General Hospital, Taipei 112, Taiwan
- Institute of Oral Biology, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Medical Research, China Medical University Hospital, China Medical University, Taichung 404, Taiwan
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 413, Taiwan
- School of Dentistry, Kaohsiung Medical University, Kaohsiung 807, Taiwan
- Department of Education and Research, Taipei City Hospital, Taipei 103, Taiwan
| |
Collapse
|
8
|
Güleç C, Sarıkaya I. The influence of aging on the fracture load of milled monolithic crowns. BMC Oral Health 2022; 22:516. [PMCID: PMC9675227 DOI: 10.1186/s12903-022-02529-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 10/24/2022] [Indexed: 11/21/2022] Open
Abstract
Background This in-vitro study was conducted to assess the effect of aging on the fracture load of molar crowns fabricated with monolithic CAD/CAM materials. Methods The crown restorations were produced from Cerasmart, Vita Enamic, and IPS e.max CAD blocks. Aging was applied to the 10 samples each of monolithic CAD/CAM materials (n = 10). Dual-axis chewing simulator (50 N, 1.1 Hz, lateral movement: 1 mm, mouth opening: 2 mm, 1,200,000 cycles) and thermocycling (± 5–55 °C, 6000 cycles) were applied as an aging procedure. 10 samples each of monolithic CAD/CAM materials without aging (n = 10) were considered the control group. 6 tested groups were obtained. Then, all samples were evaluated in a universal testing machine to determine the fracture loading values’. Results There was not a statistically significant difference between the fracture load values before and after aging for all samples of Cerasmart, Vita Enamic, and IPS e.max CAD (p > 0.005). In a comparison of the monolithic materials together, a statistically significant difference was found between the fracture load values of IPS e.max CAD and Vita Enamic crowns before aging (p = 0.02). Also, Vita Enamic crowns (1978,71 ± 364,05 N) were found different from the IPS e.max CAD (p = 0.005) and Cerasmart crowns (p = 0.041) after aging. Conclusions Dynamic aging with 1.200.000 cycles was found to have no effect to fracture loading on milled Cerasmart, Vita Enamic, and IPS e.max CAD monolithic crowns.
Collapse
Affiliation(s)
- Ceyda Güleç
- grid.411550.40000 0001 0689 906XDepartment of Prosthodontics, Faculty of Dentistry, Tokat Gaziosmanpasa University, Ali Şevki Erek Campus, 60100 Tokat, Turkey
| | - Işıl Sarıkaya
- grid.411550.40000 0001 0689 906XDepartment of Prosthodontics, Faculty of Dentistry, Tokat Gaziosmanpasa University, Ali Şevki Erek Campus, 60100 Tokat, Turkey
| |
Collapse
|
9
|
Sasany R, Yilmaz B. Marginal discrepancy and fracture load of thermomechanically fatigued crowns fabricated with different CAD-CAM techniques. J Prosthodont 2022. [PMID: 36254611 DOI: 10.1111/jopr.13612] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 10/09/2022] [Indexed: 12/01/2022] Open
Abstract
PURPOSE To assess the effect of CAD-CAM technique (monolithic, CAD-on, or CAD-on cemented) and thermomechanical fatigue on the marginal discrepancy and fracture load of ceramic crowns. MATERIAL AND METHODS A total of 90 brass master dies were fabricated to investigate marginal adaptation and fracture load. A mandibular first molar crown's median measurements were loaded into CAD software and divided into 2 crown design groups: Monolithic (M)(IPS e.max zirCAD)(n = 30) or CAD-on core (IPS e.max zirCAD) and lithium disilicate veneer (IPS e.max CAD) (n = 60). The crowns and cores were milled, seated on their respective dies, and marginal discrepancy values were measured by using microcomputed tomography. After veneers were milled, the cores in veneer groups were divided into 2 groups; veneers bonded with fusion glass-ceramic (IPS e.max CAD Crystal) in CAD-on group (CO) and CAD-on cemented group (CO-C) where veneers were cemented (RelyX U200) onto cores (CO-C). The marginal discrepancy measurements were remade and the crowns were subjected to thermomechanical fatigue (TMF) by using a chewing simulator and thermocycling (5-55°C, 1,200,000 cycles). Marginal discrepancy measurements were repeated and the crowns were subjected to fracture load test by using a universal test device. Data were analyzed statistically by analysis of variance (ANOVA) and Tukey's honestly significant difference test (α = 0.05). RESULTS All crown groups had similar marginal discrepancy before veneering. Veneering and cementation on die increased the marginal discrepancy of crowns in cemented CAD-on group. Thermomechanical fatigue increased the marginal discrepancy of both CAD-on groups. Monolithic crown group had the lowest marginal discrepancy after thermomechanical fatigue (P<0.001), and the highest fracture load (P<0.001) CONCLUSIONS: Fabrication technique affected the marginal fit and fracture load of CAD-CAM crowns after thermomechanical fatigue. All crowns survived the thermomechanical fatigue test without dislodgement or fracture. Monolithic crowns had the best fit and highest fracture load after fatigue testing. The CAD-on systems had similar marginal discrepancies, and static loading reproduced veneer chipping. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Rafat Sasany
- Prosthodontist, Private Practice, Samsun, Turkey
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, University of Bern, School of Dental Medicine, Bern, Switzerland.,Department of Restorative, Preventive, and Pediatric Dentistry, University of Bern, School of Dental Medicine, Bern, Switzerland
| |
Collapse
|
10
|
Pöppel ML, Rosentritt M, Sturm R, Beuer F, Hey J, Schmid A, Schmidt F. Fracture Load and Fracture Patterns of Monolithic Three-Unit Anterior Fixed Dental Prostheses after In Vitro Artificial Aging-A Comparison between Color-Gradient and Strength-Gradient Multilayer Zirconia Materials with Varying Yttria Content. J Clin Med 2022; 11. [PMID: 36078912 DOI: 10.3390/jcm11174982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 08/18/2022] [Accepted: 08/19/2022] [Indexed: 12/02/2022] Open
Abstract
(1) Background: Due to advantages such as avoidance of chipping, pulp-friendly tooth preparation and cost reduction, zirconia is increasingly being used monolithically without veneering. Nevertheless, to enable good aesthetics, various multilayer systems have been developed. The aim of this study was to investigate the impact of different zirconia multilayer strategies and yttria levels on fracture load, fracture pattern, stress distribution and surface roughness. (2) Methods: Monolithic three-unit anterior FDPs were made from three different color-gradient zirconia multilayer materials with different yttria levels corresponding to varying strength and degrees of translucency grades (Katana HTML, STML, UTML, Kuraray) and one strength-gradient zirconia multilayer material (Katana YML, Kuraray) and artificially aged in a chewing simulator (1.2 × 106 load cycles, 50 N, 2 × 3000 thermocycles, 5−55 °C). Analyses of fracture load, fracture pattern, fracture surfaces, stress distribution and roughness were performed after the fracture load test. Shapiro−Wilk, Kruskal−Wallis, Mann−Whitney U-tests and one-way ANOVA were used (p < 0.05). (3) Results: Fracture loads of the high strength color-gradient material HTML and the strength-gradient material YML were comparable after 5 years of aging (p = 0.645). Increasing yttria levels resulted in a decrease in fracture resistance of 42−57% (p < 0.05). Surface roughness of different zirconia generations is comparable after polishing and aging. (4) Conclusions: Color-gradient multilayer zirconia materials and new strength-gradient zirconia materials with similar yttria levels in the basal layers show comparable mechanical properties and are suitable for anterior FDPs.
Collapse
|
11
|
Atalay P, Öztaş DD. Fatigue resistance and fracture strength of narrow-diameter one-piece zirconia implants with angled abutments. J ESTHET RESTOR DENT 2022; 34:1060-1067. [PMID: 35855644 DOI: 10.1111/jerd.12944] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/05/2022] [Accepted: 07/07/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVE Zirconia implants are assumed to satisfy the esthetic requirements that titanium implants cannot meet, however, there are not enough studies in the literature about narrow-diameter and angled zirconia implants that can be preferred especially in the anterior region. This in vitro study aimed to evaluate the fatigue resistance and fracture strength of narrow-diameter zirconia implants with angled abutments. MATERIALS AND METHODS Forty-eight one-piece experimental zirconia implants and monolithic zirconia crowns were produced from 3-YTZP blanks. The implant diameters (3.0 or 3.7 mm) and the restoration types were determined according to three intraoral regions (upper central incisors, lower central incisors, and upper canine), and abutments were designed as straight or 15° angled. The samples were subjected to chewing simulation corresponding to 5 years of clinical performance and then the static loading test. The survival rates of groups were measured by the Kaplan-Meier log-rank test, and the fracture load values were estimated by using Kruskal-Wallis and Mann-Whitney U tests (p < 0.05). RESULTS All 3.0 mm diameter implants failed the fatigue test. The fatigue resistance of the implants with angled abutments was significantly lower than the straight abutments, and different crown designs were found to affect survival rates significantly. The fracture strengths of the surviving groups were above the maximum physiological chewing forces, and the differences were not significant. CONCLUSIONS The implant diameter, abutment angle, and restoration type have a significant effect on the fatigue behavior of zirconia implants. CLINICAL SIGNIFICANCE The fracture strengths of the one-piece zirconia implants with a 3.7 mm diameter and a 15° abutment angle are above the chewing forces for the anterior intraoral region.
Collapse
Affiliation(s)
- Pelin Atalay
- Department of Prosthodontics, Faculty of Dentistry, University of Niğde Ömer Halisdemir, Niğde, Turkey
| | - Doğan Derya Öztaş
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| |
Collapse
|
12
|
Alshahrani FA, Hamid SK, Alghamdi LA, Alqarawi FK, Al-Dulaijan YA, AlRumaih HS, Alalawi H, Al Ghamdi MA, Alzoubi F, Gad MM. Impact of Polymerization Technique and ZrO 2 Nanoparticle Addition on the Fracture Load of Interim Implant-Supported Fixed Cantilevered Prostheses in Comparison to CAD/CAM Material. Dent J (Basel) 2022; 10:102. [PMID: 35735644 DOI: 10.3390/dj10060102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 05/16/2022] [Accepted: 06/06/2022] [Indexed: 01/25/2023] Open
Abstract
ZrO2 nanoparticles (ZNPs) have excellent physical properties. This study investigated the fracture load of implant-supported, fixed cantilevered prosthesis materials, reinforced with ZNPs and various polymerization techniques, compared with conventional and CAD/CAM materials. Sixty specimens were made from two CAD/CAM; milled (MIL) (Ceramill TEMP); and 3D-printed (NextDent Denture 3D+). Conventional heat-polymerized acrylic resin was used to fabricate the other specimens, which were grouped according to their polymerization technique: conventionally (HP) and autoclave-polymerized (AP); conventionally cured and reinforced with 5 wt% ZNPs (HPZNP); and autoclave reinforced with 5 wt% ZNPs (APZNP). The specimens were thermocycled (5000 cycles/30 s dwell time). Each specimen was subjected to static vertical loading (1 mm/min) using a universal Instron testing machine until fracture. Scanning electron microscopy was used for fracture surface analyses. The ANOVA showed significant fracture load differences between all the tested groups (p = 0.001). The Tukey post hoc tests indicated a significant difference in fracture load between all tested groups (p ˂ 0.001) except HP vs. HPZNP and AP vs. MIL. APZNP had the lowest mean fracture load value (380.7 ± 52.8 N), while MIL had the highest (926.6 ± 82.8 N). The CAD/CAM materials exhibited the highest fracture load values, indicating that they could be used in long-term interim prostheses. Autoclave polymerization improved fracture load performance, whereas ZrO2 nanoparticles decreased the fracture load performance of cantilevered prostheses.
Collapse
|
13
|
Rohr N, Nüesch R, Greune R, Mainetti G, Karlin S, Zaugg LK, Zitzmann NU. Stability of Cantilever Fixed Dental Prostheses on Zirconia Implants. Materials (Basel) 2022; 15:3633. [PMID: 35629659 DOI: 10.3390/ma15103633] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 05/13/2022] [Accepted: 05/16/2022] [Indexed: 01/13/2023]
Abstract
Background: The objective was to determine the optimal connector size and position within zirconia disks for implant-supported cantilever fixed dental prostheses (ICFDP). Methods: Two-unit ICFDPs (n = 60) were designed for the premolar region with connector sizes of either 9 or 12 mm2 and positioned in the enamel or dentin layer of two different types of zirconia disks. The restorations were milled and cemented onto zirconia implants. After simulated chewing for 1.2 Mio cycles, the fracture load was measured and fractures were analyzed. Results: No fractures of ICFDPs or along the implants were detected after simulated aging. The mean fracture load values were significantly higher for a connector size of 9 mm2 (951 N) compared with 12 mm2 (638 N). For the zirconia material with a higher biaxial flexural strength, the fracture load values were increased from 751 to 838 N, but more implant fractures occurred. The position within the zirconia disk did not influence the fracture load. Conclusions: A connector size of 9 mm2 and a zirconia material with a lower strength should be considered when designing ICFDPS on zirconia implants to reduce the risk of fractures along the intraosseous implant portion.
Collapse
|
14
|
Schmidt MB, Rosentritt M, Hahnel S, Wertz M, Hoelzig H, Kloess G, Koenig A. Fracture behavior of cantilever fixed dental prostheses fabricated from different zirconia generations. Quintessence Int 2022; 53:414-422. [PMID: 35274515 DOI: 10.3290/j.qi.b2793243] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
OBJECTIVE The aim of this study was to compare the fracture behavior of cantilever fixed dental prostheses (FDPs) fabricated from 3Y-TZP, 4Y-TZP, or 5Y-TZP zirconia. METHOD AND MATERIALS Posterior cantilever FDPs (three groups, each n = 16) were digitally designed and milled. After sintering, eight specimens/group were stored in demineralized water for 72 hours; eight specimens/group were subjected to accelerated aging using chewing simulation with thermal cycling (1,200,000 × 50 N; 2 × 3,000 × 5°C/55°C; H2O, 2 minutes/cycle) and finally stored in demineralized water for 24 hours. The cantilever FDPs were then statically loaded to failure to determine fracture load. Phase transformation towards the monoclinic phase was controlled with x-ray diffractometry. RESULTS One failure was identified after accelerated aging in the 5Y-TZP group. Fracture load decreased with increasing yttria content and decreasing bending strength. Accelerated aging using chewing simulation with thermal cycling caused a significant decline in fracture load. All FDPs failed in the area of the prepared tooth and in proximity to the cantilever, where the largest bending moment occurred. The yttria content had no influence on the type of fracture. With increasing yttria content, the relation between deformation and fracture load decreased only slightly. On the surface of FDPs that had been subjected to chewing simulation, no phase transformation towards the monoclinic phase (eg, low temperature degradation) was detected. CONCLUSION Within the limitations of a laboratory study, the data indicate that 3Y-, 4Y-, and 5Y-TZP may be employed as material for the fabrication of permanent posterior cantilever FDPs. However, more data are necessary to finally advocate the application of 5-Y-TZP. (Quintessence Int 2022;53:414-422; doi: 10.3290/j.qi.b2793243).
Collapse
|
15
|
Heidari N, Amawi R, Seweryniak P, Bakitian F, Vult von Steyern P. Fracture Resistance and Fracture Behaviour of Monolithic Multi-Layered Translucent Zirconia Fixed Dental Prostheses with Different Placing Strategies of Connector: An in vitro Study. Clin Cosmet Investig Dent 2022; 14:61-69. [PMID: 35345450 PMCID: PMC8957397 DOI: 10.2147/ccide.s344941] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 02/03/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To evaluate the effect of different placing strategies performed in the connector area on fracture resistance and fracture behaviour of monolithic multi-layered translucent zirconia fixed dental prostheses (FDPs). Materials and Methods Thirty 3-unit monolithic FDPs were produced and divided into three groups (n = 10) based on the different strategies for placing the connector area of FDPs in multi-layered zirconia blank with varying contents of yttria ranging from 4 to 5 mol%. The groups were as follows: FDPs with connectors placed in dentin layer with 4 mol% yttria content, FDPs with connectors placed in gradient layer, and FDPs with connectors placed in translucent layer with 5 mol% yttria content. A final group (n = 10) of conventional monolithic zirconia with a monolayer of yttria content (4 mol%) has been used as a control group. The specimens were artificially aged using thermocycling and pre-loading procedures and subsequently loaded to fracture using a universal testing machine. Fracture loads and fracture behaviour were analyzed using one-way ANOVA and Fisher’s exact tests and statistically evaluated (p ≤ 0.05). Results There were no significant differences in fracture loads among the groups based on the placing strategies of the connector area of the FDPs in the multi-layered translucent zirconia blank (p > 0.05). There was no significant difference in fracture loads between monolithic multi-layered translucent zirconia and conventional monolithic translucent zirconia materials (p > 0.05). Fracture behaviour of FDPs with connector area placed in translucent layer differed significantly compared to FDPs with connector area placed in dentin layer and FDPs in control group (p = 0.004). Conclusion The placing strategies of the connector used in the computer aided design and manufacturing procedures do not considerably affect fracture resistance of monolithic FDPs made of multi-layered translucent zirconia. Monolithic FDPs made of multi-layered translucent zirconia show comparable strength to FDPs made of conventional translucent zirconia, but with different fracture behaviour.
Collapse
Affiliation(s)
- Nada Heidari
- Department of Materials Science and Technology, Malmö University, Malmö, Sweden
| | - Rasha Amawi
- Department of Materials Science and Technology, Malmö University, Malmö, Sweden
| | | | - Fahad Bakitian
- Department of Restorative Dentistry, Umm Al-Qura University, Makkah, Saudi Arabia
| | | |
Collapse
|
16
|
Sadeqi HA, Baig MR, Al-Shammari M. Evaluation of Marginal/Internal Fit and Fracture Load of Monolithic Zirconia and Zirconia Lithium Silicate (ZLS) CAD/CAM Crown Systems. Materials (Basel) 2021; 14:ma14216346. [PMID: 34771872 PMCID: PMC8585271 DOI: 10.3390/ma14216346] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Revised: 10/15/2021] [Accepted: 10/20/2021] [Indexed: 11/24/2022]
Abstract
Fit accuracy and fracture strength of milled monolithic zirconia (Zi) and zirconia-reinforced lithium silicate (ZLS) crowns are important parameters determining the success of these restorations. This study aimed to evaluate and compare the marginal and internal fit of monolithic Zi and ZLS crowns, along with the fracture load, with and without mechanical aging. Thirty-two stone dies acquired from a customized master metal molar die were scanned, and ceramic crowns (16 Zi Ceramill Zolid HT+ and 16 ZLS Vita Suprinity) were designed and milled. Absolute marginal discrepancies (AMD), marginal gaps (MG), and internal gaps (IG) of the crowns, in relation to the master metal die, were evaluated using x-ray nanotomography (n = 16). Next, thirty-two metal dies were fabricated based on the master metal die, and crowns (16 Zi; 16 ZLS) cemented and divided into four groups of eight each; eight Zi with mechanical aging (MA), eight Zi without mechanical aging (WMA), eight ZLS (MA), and eight ZLS (WMA). Two groups of crowns (Zi-MA; ZLS-MA) were subjected to 500,000 mechanical cycles (200 ± 50 N, 10 Hz) followed by axial compressive strength testing of all crowns, until failure, and the values were recorded. Independent sample t tests (α = 0.05) revealed no significant differences between Zi and ZLS crowns (p > 0.05); for both internal and marginal gaps, however, there were significant differences in AMD (p < 0.005). Independent samples Mann–Whitney U and Kruskal–Wallis tests revealed significant differences between the two materials, Zi and ZLS, regardless of fatigue loading, and for the individual material groups based on aging (α = 0.05). Multiple comparisons using Bonferroni post-hoc analysis showed significant differences between Zi and ZLS material groups, with or without aging. Within the limitations of this study, the ZLS crown fit was found to be on par with Zi, except for the AMD parameter. As regards fracture resistance, both materials survived the normal range of masticatory forces, but the Zi crowns demonstrated greater resistance to fracture. The monolithic Zi and ZLS crowns seem suitable for clinical application, based on the fit and fracture strength values obtained.
Collapse
Affiliation(s)
- Haneen A. Sadeqi
- Department of Bioclinical Sciences, Faculty of Dentistry, Kuwait University, P.O. Box 24923,
Safat 13110, Kuwait; (H.A.S.); (M.A.-S.)
| | - Mirza Rustum Baig
- Department of Restorative Sciences (Prosthodontics), Faculty of Dentistry, Kuwait University, P.O. Box 24923,
Safat 13110, Kuwait
- Correspondence:
| | - Mohammad Al-Shammari
- Department of Bioclinical Sciences, Faculty of Dentistry, Kuwait University, P.O. Box 24923,
Safat 13110, Kuwait; (H.A.S.); (M.A.-S.)
| |
Collapse
|
17
|
Hanes B, Feitosa S, Phasuk K, Levon JA, Morton D, Lin WS. Fracture Resistance Behaviors of Titanium-Zirconium and Zirconia Implants. J Prosthodont 2021; 31:441-446. [PMID: 34632673 DOI: 10.1111/jopr.13440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/03/2021] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To evaluate the fracture resistance behaviors of titanium-zirconium, one-piece zirconia, and two-piece zirconia implants restored by zirconia crowns and different combinations of abutment materials (zirconia and titanium) and retention modes (cement-retained and screw-retained zirconia crowns). MATERIAL AND METHODS Three research groups (n=12) were evaluated according to combinations of abutment material, retention mode, and implant type. In the control group (TTC), titanium-zirconium implants (∅ 4.1 mm RN, 12 mm, Roxolid; Straumann USA, Andover, MA) and prefabricated titanium abutments (RN synOcta Cementable Abutment, H 5.5 mm; Straumann USA) were used to support cement-retained zirconia crowns. In the second group (ZZC), one-piece zirconia implants (PURE Ceramic Implant Monotype, ∅ 4.1 mm RD, 12 mm, AH 5.5 mm; Straumann USA) were used to support cement-retained zirconia crowns. In the third group (ZTS), two-piece zirconia implants (PURE Ceramic Implant, ∅ 4.1 mm RD, 12 mm) and prefabricated titanium abutments (CI RD PUREbase Abutment, H 5.5 mm) were used to support screw-retained zirconia crowns. All zirconia crowns were manufactured in the same anatomic contour with a 5-axis dental mill and blended 3 and 5 mol% yttria-stabilized zirconia (LayZir A2). Implants were inserted into specimen holders made of epoxy resin-glass fiber composite. All specimens were then subject to artificial aging in an incubator at 37°C for 90 days. Fracture resistance of specimen assemblies was tested under static compression load using the universal testing machine based on ISO14801 specification. The peak fracture loads were recorded. All specimens were examined at the end of the test microscopically at 5× and 10× magnification to detect any catastrophic failures. Comparisons between groups for differences in peak fracture load were made using Wilcoxon Rank Sum tests and Weibull and Kaplan-Meier survival analyses (α = 0.05). RESULTS The TTC group (942 ± 241 N) showed significantly higher peak fracture loads than the ZZC (645 ± 165 N) and ZTS (650 ± 124 N) groups (p < 0.001), while there was no significant difference between ZZC and ZTS groups (p = 0.940). The survival probability based on the Weibull and Kaplan-Meier models demonstrated different failure molds between titanium-zirconium and zirconia implants, in which the TTC group remained in the plastic strain zone for a longer period before fracture when compared to ZZC and ZTS groups. Catastrophic failures, with implant fractures at the embedding level or slightly below, were only observed in the ZZC and ZTS groups. CONCLUSIONS Cement-retained zirconia crowns supported by titanium-zirconium implants and prefabricated titanium abutments showed superior peak fracture loads and better survival probability behavior. One-piece zirconia implants with cement-retained zirconia crowns and two-piece zirconia implants with screw-retained zirconia crowns on prefabricated titanium abutment showed similar peak fracture loads and survival probability behavior. Titanium-zirconium and zirconia implants could withstand average intraoral mastication loads in the incisor region. This study was conducted under static load, room temperature (21.7°C), and dry condition, and full impacts of intraoral hydrothermal aging and dynamic loading conditions on the zirconia implants should be considered and studied further.
Collapse
Affiliation(s)
- Brenda Hanes
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN
| | - Sabrina Feitosa
- Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, Indianapolis, IN
| | - Kamolphob Phasuk
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN
| | - John A Levon
- Department of Prosthodontic Dentistry, Indiana University School of Dentistry, Indianapolis, IN
| | - Dean Morton
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN
| | - Wei-Shao Lin
- Advanced Education Program in Prosthodontics, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN
| |
Collapse
|
18
|
Zandinejad A, Das O, Barmak AB, Kuttolamadom M, Revilla-León M. The Flexural Strength and Flexural Modulus of Stereolithography Additively Manufactured Zirconia with Different Porosities. J Prosthodont 2021; 31:434-440. [PMID: 34580962 DOI: 10.1111/jopr.13430] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 09/01/2021] [Accepted: 09/09/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE Additive manufacturing (AM) technologies are capable of fabricating complex geometries with different porosities. However, the effect of such porosities on mechanical properties of stereolithography (SLA) AM zirconia with different porosities is unclear. The purpose of this in vitro study was to investigate the mechanical properties namely flexural strength, and flexural modulus of AM zirconia with different porosities. MATERIALS AND METHODS A bar (25 × 4 × 3 mm) for flexural strength test (ISO standard 6872/2015) was designed by CAD software program and standard tessellation language (STL) file was obtained. The STL file was used to fabricate a total of 80 bars in four groups. Three experimental groups each containing 20 samples were manufactured using an SLA ceramic printer (CeraMaker 900; 3DCeram Co) and zirconia material (3DMix ZrO2 paste; 3DCeram Co) with different sintering post processing to achieve different porosities including 0%-porosity (AMZ0), 20%-porosity (AMZ20), and 40%-porosity (AMZ40). The same STL file was used for subtractive manufacturing or milling of 20 zirconia bars as control group (CNCZ) with the same dimensions using a commercial zirconia. Three-point bending tests were performed for all groups following ISO standard 6872/2015 specification using a universal testing machine. Outcomes measured included load at fracture, mean flexural strength, and flexural modulus and they were compared across the experimental groups using a one-way ANOVA. Post hoc pair wise comparison between each pair of the groups were performed using Tukey test. RESULTS There was a significant difference between the four groups, in terms of fracture load, flexural strength and flexural modulus using one-way ANOVA. AM zirconia with 0% porosity (AMZ0) showed the highest value for fracture load (1132.7 ± 220.6 N), flexural strength (755.1 ± 147.1 MPa) and flexural modulus (41,273 ± 2193 MPa) and AM zirconia with 40% porosity (AMZ40) showed the lowest fracture load (72.13 ± 13.42 N), flexural strength (48.09 ± 8.95 MPa) and flexural modulus (7177 ± 506 MPa). Tukey's pairwise comparisons detected a significant difference between all the possible pairs for all variables except flexural modulus between AMZ0 and CNCZ. The Weibull moduli presented the lowest value for AMZ20 (4.4) followed by AMZ40 (6.1), AMZ0 (6.1), and the highest value was for CNCZ (8.1). CONCLUSION AM zirconia with 0% porosity showed significantly higher flexural strength and flexural modulus when compared to milled and AM zirconia with 20% and 40% porosities.
Collapse
Affiliation(s)
| | - Omprakash Das
- College of Engineering, Texas A&M University, College Station, TX
| | | | | | - Marta Revilla-León
- College of Dentistry, Texas A&M University, Dallas, TX.,School of Dentistry, University of Washington, Seattle, WA.,Revilla Research Center, Madrid, Spain
| |
Collapse
|
19
|
Kongkiatkamon S, Booranasophone K, Tongtaksin A, Kiatthanakorn V, Rokaya D. Comparison of Fracture Load of the Four Translucent Zirconia Crowns. Molecules 2021; 26:5308. [PMID: 34500741 DOI: 10.3390/molecules26175308] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 08/03/2021] [Accepted: 08/17/2021] [Indexed: 02/07/2023] Open
Abstract
Recently, translucent zirconia has become the most prevalent material used as a restorative material. This study aimed to compare the crown fracture load of the four most common different translucent zirconia brands available in the market at 1.5 mm thickness. Standardized tooth preparations for a full ceramic crown were designed digitally with software (AutoCAD) by placing a 1.0 mm chamfer margin and 1.5 mm occluso-cervical curvature for the crown sample manufacturing. Stylized crowns were chosen to control the thickness of the crown. The axial and occlusal thickness were standardized to 1.5 mm thickness except at the central pit, which was 1.3 mm thick. The STL file for the tooth dies was prepared using software (3Shape TRIOS® Patient Monitoring, Copenhagen, Denmark). The tooth dies were printed with a resin material (NextDent Model 2.0, Vertex-Dental B.V., Soesterberg, The Netherlands) using a 3D printing software (3D Sprint® Client Version 3.0.0.2494) from a 3D printer (NextDent™ 5100, Vertex-Dental B.V., Soesterberg, The Netherlands). The printing layer thickness was 50 µm. Then, a total of twenty-eight (N = 28) stylized crowns were milled out of AmannGirrbach (Amann Girrbach GmbH, Pforzheim, Germany) (n = 7), Cercon HT (Dentsply Sirona, Bensheim, Germany) (n = 7), Cercon XT (Dentsply Sirona, Bensheim, Germany) (n = 7), and Vita YZ XT (Zahnfabrik, Bäd Sackingen, Germany) (n = 7). Following sintering the crowns, sandblasting was performed and they were bonded to the tooth dies with the resin cement (RelyX U-200, 3M ESPE, Seefeld, Germany) and permitted to self-cure under finger pressure for 6 min. The crowns were loaded on the occlusal surface in a universal testing machine (MTS Centurion) with a stainless-steel ball indenter (7 mm radius) with a loading rate of 1 mm/min to contact the stylized crowns on each of the four cusps until failure. A rubber sheet (1.5 mm thickness) was positioned between the crown and indenter, which helped with the load distribution. Statistical analysis was done using SPSS version 20 (IBM Company, Chicago, USA). The fracture loads were analyzed using Dunnett’s T3 test, and the number of cracks was analyzed using the Mann–Whitney U test among the groups. The significant level was set at p value = 0.05. The mean fracture loads were 3086.54 ± 441.74 N, 4804.94 ± 70.12 N, 3317.76 ± 199.80 N, and 2921.87 ± 349.67 N for AmannGirrbac, Cercon HT, Cercon XT, and Vita YZ XT, respectively. The mean fracture loads for the surfaces with the greatest number of cracks (excluding the occlusal surfaces) were on the lingual surface for AmannGirrbach and Cercon HT, on the distal and mesial for Cercon XT, and on the buccal for Vita YZ XT. We found that the AmannGirrbach had the most overall cracks. Cercon XT had the greatest number of occlusal cracks and appeared to be the most shattered. Cercon HT had the least number of cracks. In conclusion, Cercon HT presented the best strength properties, the highest fracture load, and no visible cracks. AmannGirrbach presented the lowest strength properties.
Collapse
|
20
|
Alqahtani F, AlHomidhi M. Evaluation of the mode of failure of abutments supporting implant-supported fixed partial dentures via different retention techniques. Niger J Clin Pract 2021; 24:220-224. [PMID: 33605912 DOI: 10.4103/njcp.njcp_232_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Objective The objective was to in-vitro evaluate the mode of failure of abutments supporting fixed partial dentures (FPDs) via different retention techniques. Materials and Methods Thirty-six implants with diameter and length of 4.5 and 13 mm, respectively, were used to prepare 18 samples of FPDs. Based on the variations on abutment's design, the FPDs were divided into three groups: Group A is cement-based retention; Group B is screw-based retention; and Group C is multiunit screw-based retention. Using a chewing simulator, cyclic loads of 1,250,000 load cycles with the load of 70N were applied on all samples to simulate 5 years of human functional chewing. The samples were loaded until failure using an electromechanical test machine. Sample-size estimation was done and fracture-load values were recorded as means and corresponding standard deviations; and group comparisons were done using one-way analysis of variance and Tukey's post hoc tests. A P value below 0.01 was nominated as an indicator of statistical significance. Results In total, 36 samples (12 implant-abutment connections per group) were assessed. Abutment bending was observed in 6 (50%), 6 (50%) and 6 (50%) samples in groups A, B and C, respectively. De-attachment of the FPD form the abutment occurred in 5 (41.7%) and 5 (41.7%) samples in groups A and C, respectively. Screw fracture and fracture of FPD at the connector side occurred in 1 (8.3%) and 1 (8.3%) sample in groups A and C, correspondingly. Failure of the FPD was more often encountered in groups A (100%) and C (100%), compared to group B (50%). Conclusion All abutments underwent failures under cyclic loading with abutment bending being the most common failure mode. Cement- and multi-screw-supported abutments fail more often than screw-supported abutments.
Collapse
Affiliation(s)
- F Alqahtani
- Department of Prosthodontics, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj, Saudi Arabia
| | - M AlHomidhi
- Department of Prosthodontics, King Saud Medical City, Ministry of Health, Riyadh, Saudi Arabia
| |
Collapse
|
21
|
Rodríguez V, Tobar C, López-Suárez C, Peláez J, Suárez MJ. Fracture Load of Metal, Zirconia and Polyetheretherketone Posterior CAD-CAM Milled Fixed Partial Denture Frameworks. Materials (Basel) 2021; 14:959. [PMID: 33670544 DOI: 10.3390/ma14040959] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 02/10/2021] [Accepted: 02/15/2021] [Indexed: 01/02/2023]
Abstract
The aim of this study was to investigate the load to fracture and fracture pattern of prosthetic frameworks for tooth-supported fixed partial dentures (FPDs) fabricated with different subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Materials and Methods: Thirty standardized specimens with two abutments were fabricated to receive three-unit posterior FDP frameworks with an intermediate pontic. Specimens were randomly divided into three groups (n = 10 each) according to the material: group 1 (MM)—milled metal; group 2 (L)—zirconia; and group 3 (P)—Polyetheretherketone (PEEK). The specimens were thermo-cycled and subjected to a three-point bending test until fracture using a universal testing machine (cross-head speed: 1 mm/min). Axial compressive loads were applied at the central fossa of the pontics. Data analysis was made using one-way analysis of variance, Tamhane post hoc test, and Weibull statistics (α = 0.05). Results: Significant differences were observed among the groups for the fracture load (p < 0.0001). MM frameworks showed the highest fracture load values. The PEEK group registered higher fracture load values than zirconia samples. The Weibull statistics corroborated these results. The fracture pattern was different among the groups. Conclusions: Milled metal provided the highest fracture load values, followed by PEEK, and zirconia. However, all tested groups demonstrated clinically acceptable fracture load values higher than 1000 N. PEEK might be considered a promising alternative for posterior FPDs.
Collapse
|
22
|
Pitta J, Hjerppe J, Burkhardt F, Fehmer V, Mojon P, Sailer I. Mechanical stability and technical outcomes of monolithic CAD/CAM fabricated abutment-crowns supported by titanium bases: An in vitro study. Clin Oral Implants Res 2020; 32:222-232. [PMID: 33258267 DOI: 10.1111/clr.13693] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2020] [Revised: 11/08/2020] [Accepted: 11/21/2020] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To evaluate mechanical stability (survival and complication rates) and bending moments of different all-ceramic monolithic restorations bonded to titanium bases (hybrid abutment-crowns) or to customized titanium abutments compared to porcelain-fused-to-metal crowns (PFM) after thermo-mechanical aging. MATERIAL AND METHODS Sixty conical connection implants (4.3 mm-diameter) were divided in five groups (n = 12): PFM using gold abutment (GAbut-PFM), lithium disilicate crown bonded to customized titanium abutment (TAbut+LDS), lithium disilicate abutment-crown bonded to titanium base (TiBase+LDS), zirconia abutment-crown bonded to titanium base (TiBase+ZR), polymer-infiltrated ceramic-network (PICN) abutment-crown bonded to titanium base (TiBase+PICN). Simultaneous thermocycling (5°-55°C) and chewing simulation (1,200,000-cycles, 49 N, 1.67 Hz) were applied. Catastrophic and non-catastrophic events were evaluated under light microscope, and survival and complication rates were calculated. Specimens that survived aging were loaded until failure and bending moments were calculated. RESULTS Survival rates after aging were 100% (TAbut+LDS, TiBase+LDS), 91.7% (GA-PFM), 66.7% (TiBase+ZR) and 58.3% (TiBase+PICN) and differed among the groups (p = .006). Non-catastrophic events as screw loosening (GA-PFM) and loss of retention or micro-/macro-movement (TiBase groups) were observed. Complication rates varied among the groups (p < .001). TiBase+PICN had lower bending moment than all the other groups (p < .001). CONCLUSIONS Hybrid abutment-crowns made of lithium disilicate can be an alternative to PFM-based restorations, although concerns regarding the bonded interface between the titanium base and abutment-crown can be raised. PICN and zirconia may not be recommended due to its inferior mechanical and bonding outcomes, respectively. Titanium customized abutment with bonded lithium disilicate crown appears to be the most stable combination.
Collapse
Affiliation(s)
- João Pitta
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Jenni Hjerppe
- Departments of Oral and Maxillofacial Diseases, Helsinki University Hospital (HUH), Helsinki, Finland.,Department of Prosthodontics and Stomatognathic physiology, University of Turku, Turku, Finland
| | - Felix Burkhardt
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Vincent Fehmer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Philippe Mojon
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
23
|
Valenzuela EBS, Andrade JP, da Cunha PFJS, Bittencourt HR, Spohr AM. Fracture load of CAD/CAM ultrathin occlusal veneers luted to enamel or dentin. J ESTHET RESTOR DENT 2020; 33:516-521. [PMID: 32949221 DOI: 10.1111/jerd.12658] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 07/30/2020] [Accepted: 09/04/2020] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To evaluate, in vitro, the fracture load of IPS e.max CAD occlusal veneers at thicknesses of either 0.3 or 0.6 mm luted to enamel or dentin. MATERIALS AND METHODS Fifty human molars were randomly distributed into five groups (n = 10): G1 - healthy teeth (control); G2-0.3-mm-thick veneers luted to enamel; G3-0.6-mm-thick veneers luted to enamel; G4-0.3-mm-thick veneers luted to dentin; and G5-0.6-mm-thick veneers luted to dentin. After the luting procedures, the specimens were immersed in distilled water at 37°C for 24 hours and then subjected to mechanical loading (106 cycles at 200 N load). The specimens were subjected to a fracture load test in a universal testing machine. Two-way ANOVA and Tukey's test (α = 0.05) were used to analyze data. RESULTS Only the thickness factor was significant (P = .002). Values of fracture load followed by distinct letters represent significant differences (P < .05): G1 (3204 N ± 730)ab ; G2 (3144 N ± 729)ab ; G3 (2489 N ± 606)b ; G4 (3591 N ± 776)a ; and G5 (2770 N ± 598)ab . CONCLUSION IPS e.max ultrathin occlusal veneers luted to enamel or dentin obtained fracture load comparable to that of the healthy tooth. CLINICAL SIGNIFICANCE IPS e.max CAD ultrathin occlusal veneers at 0.3 or 0.6-mm-thick seem to provide good perspectives in relation to the clinical use.
Collapse
Affiliation(s)
| | - Jonas Pereira Andrade
- Department of Restorative Dentistry, School of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
| | | | - Hélio Radke Bittencourt
- Department of Statistics, School of Mathematics, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
| | - Ana Maria Spohr
- Department of Restorative Dentistry, School of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
| |
Collapse
|
24
|
Abdulmajeed A, Sulaiman T, Abdulmajeed A, Bencharit S, Närhi T. Fracture Load of Different Zirconia Types: A Mastication Simulation Study. J Prosthodont 2020; 29:787-791. [PMID: 32840940 DOI: 10.1111/jopr.13242] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/16/2020] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To assess the effect of yttria mol% concentration and material thickness on the biaxial fracture load (N) of zirconia with and without mastication simulation. MATERIALS AND METHODS Disk-shaped specimens (N = 120) of 3 mol% yttria-partially stabilized zirconia, 3Y-PSZ (Katana High Translucent, Kuraray Noritake), 4 mol% yttria-partially stabilized zirconia, 4Y-PSZ (Katana Super Translucent Multi Layered) and 5 mol% Yttria-partially stabilized zirconia, 5Y-PSZ (Katana Ultra Translucent Multi Layered) were prepared to thicknesses of 0.7 and 1.2 mm. For each thickness, the biaxial fracture load (N) was measured with and without mastication simulation with 1.2 million cycles at a 110-N load and simultaneous thermal cycling at 5°C to 55°C. The data were analyzed by three-way Analysis of Variance (α = 0.05) and Tukey-Kramer adjusted multiple comparison test. RESULTS Yttria mol% concentration and material thickness had a statistically significant effect on the mean biaxial fracture load (F = 388.16, p < 0.001 and F = 714.33, p < 0.001 respectively). The mean biaxial fracture load ranged from the highest to the lowest; 3Y-PSZ, 4Y-PSZ, and 5Y-PSZ (p = 0.012). The mean biaxial fracture load of the 1.2 mm thickness groups was significantly higher than 0.7 mm thickness at any given condition (p = 0.002). Not all specimens survived the mastication simulation protocol. Fifty percent of the 0.7-mm-thick 4Y-PSZ specimens, 70% of the 0.7-mm-thick 5Y-PSZ specimens and 20% of 1.2-mm-thick 5Y-PSZ specimens fractured during mastication simulation. Mastication simulation had no statistically significant effect on the biaxial fracture load (F = 1.24, p = 0.239) of the survived specimens. CONCLUSIONS Lowering yttria mol% concentration and increasing material thickness significantly increases the fracture load of zirconia. At 0.7 mm thickness, only 3Y-PSZ survived masticatory simulation. A minimum material thickness of 1.2 mm is required for 4Y-PSZ or 5Y-PSZ.
Collapse
Affiliation(s)
- Awab Abdulmajeed
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku, Finland.,Department of General Practice, School of Dentistry, Virginia Commonwealth University, Richmond, VA
| | - Taiseer Sulaiman
- Division of Comprehensive Oral Health, Adams School of Dentistry, University of North Carolina, Chapel Hill, NC
| | - Aous Abdulmajeed
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku, Finland.,Department of General Practice, School of Dentistry, Virginia Commonwealth University, Richmond, VA
| | - Sompop Bencharit
- Department of General Practice, School of Dentistry, Virginia Commonwealth University, Richmond, VA.,Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, VA
| | - Timo Närhi
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku, Finland.,City of Turku, Welfare Division, Turku, Finland
| |
Collapse
|
25
|
Bencun M, Ender A, Wiedemeier DB, Mehl A. Fracture Load of CAD/CAM Feldspathic Crowns Influenced by Abutment Material. Materials (Basel) 2020; 13:E3407. [PMID: 32748827 DOI: 10.3390/ma13153407] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Revised: 07/22/2020] [Accepted: 07/31/2020] [Indexed: 11/30/2022]
Abstract
In vitro studies investigating the mechanical properties of dental reconstructions use various materials to replicate prepared teeth. However, no uniform recommendation exists as to which material is most suitable for standardized testing. The purpose of this study was to identify a material that resembles human dentin in fracture load tests. Sixteen human teeth were scanned with an intraoral scanner to obtain copies of the original crown morphology and were then prepared for crowns. Replica dies of the prepared teeth including the root morphology were fabricated with a Computer-aided design and computer-aided manufacturing (CAD/CAM) system and divided into four groups: (A) reinforced composite (RC); (B) human dentin (HD); (C) polymethyl methacrylate (PM); and (D) hybrid ceramic (HC). Sixty-four feldspar ceramic crowns were designed with the biocopy mode, fabricated with a CAD/CAM system, luted on the dies, and then with the roots embedded in polymethyl methacrylate. Care was taken to position all specimens of the same morphology identically. Thermo-mechanical load cycling was performed in a chewing simulator followed by fractural loading of the crowns. A mixed effect linear model was fitted to the data, and pairwise contrasts were estimated on the marginal means and corrected for multiple testing according to Tukey (α = 0.05). The means for fracture load (N) were 2435 N (95% CI (2162, 2709)) for hybrid ceramic, 1838 N (95% CI (1565, 2112)) for reinforced composite, 1670 N (95% CI (1396, 1943)) for human tooth and 1142 N (95% CI (868, 1415)) for polymethyl methacrylate abutment materials. Post-hoc pairwise contrasts revealed a statistically significant (p < 0.05) difference among all groups except for reinforced composite and human dentin (p = 0.76). The results indicate that the mechanical properties of abutment dies play a significant role for a possible substitution of natural teeth in in vitro studies.
Collapse
|
26
|
Bethke A, Pieralli S, Kohal RJ, Burkhardt F, von Stein-Lausnitz M, Vach K, Spies BC. Fracture Resistance of Zirconia Oral Implants In Vitro: A Systematic Review and Meta-Analysis. Materials (Basel) 2020; 13:E562. [PMID: 31991565 PMCID: PMC7040771 DOI: 10.3390/ma13030562] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 01/15/2020] [Accepted: 01/21/2020] [Indexed: 12/27/2022]
Abstract
Various protocols are available to preclinically assess the fracture resistance of zirconia oral implants. The objective of the present review was to determine the impact of different treatments (dynamic loading, hydrothermal aging) and implant features (e.g., material, design or manufacturing) on the fracture resistance of zirconia implants. An electronic screening of two databases (MEDLINE/Pubmed, Embase) was performed. Investigations including > 5 screw-shaped implants providing information to calculate the bending moment at the time point of static loading to fracture were considered. Data was extracted and meta-analyses were conducted using multilevel mixed-effects generalized linear models (GLMs). The Šidák method was used to correct for multiple testing. The initial search resulted in 1864 articles, and finally 19 investigations loading 731 zirconia implants to fracture were analyzed. In general, fracture resistance was affected by the implant design (1-piece > 2-piece, p = 0.004), material (alumina-toughened zirconia/ATZ > yttria-stabilized tetragonal zirconia polycrystal/Y-TZP, p = 0.002) and abutment preparation (untouched > modified/grinded, p < 0.001). In case of 2-piece implants, the amount of dynamic loading cycles prior to static loading (p < 0.001) or anatomical crown supply (p < 0.001) negatively affected the outcome. No impact was found for hydrothermal aging. Heterogeneous findings of the present review highlight the importance of thoroughly and individually evaluating the fracture resistance of every zirconia implant system prior to market release.
Collapse
Affiliation(s)
- Annalena Bethke
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Stefano Pieralli
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Felix Burkhardt
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Manja von Stein-Lausnitz
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Kirstin Vach
- Institute of Medical Biometry and Statistics, Faculty of Medicine, Medical Center—University of Freiburg, University of Freiburg, Stefan-Meier-Str. 26, 79104 Freiburg, Germany;
| | - Benedikt Christopher Spies
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| |
Collapse
|
27
|
Li X, Zhu ZM, Li ZY, Zhou JR, Chen WC. [All-ceramic premolar guiding plate retains resin-bonded fixed partial dentures]. Hua Xi Kou Qiang Yi Xue Za Zhi 2019; 37:285-289. [PMID: 31218863 DOI: 10.7518/hxkq.2019.03.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE This study aims to investigate the fracture resistance and short-term restorative effects of resin-bonded fixed partial dentures (RBFPDs) made from heat-pressed lithium-disilicate-based glass-ceramic (IPS e.max press) and zirconia ceramic (WIELAND) and retained by all-ceramic guiding plates when used to restore missing mandibular second premolars. METHODS A total of 64 human mandibular first premolars and first molars were prepared as abutments, then were randomly divided into 4 groups (n=8): E0, heat-pressed ceramic RBFPDs, no cyclic loading; E1, heat-pressed ceramic RBFPDs exposed to 300 000 cycles of dynamic loading; W0, zirconia ceramic RBFPDs, no cyclic loading; and W1, zirconia ceramic RBFPDs exposed to 300 000 cycles of dynamic loading. Fracture strength was tested in a universal testing machine. RESULTS The medians of fracture strength were 1 242.85 N±260.11 N (E0), 1 650.85 N±206.77 N (W0), 1 062.60 N±179.98 N (E1), and 1 167.61 N±265.50 N (W1). Statistical analysis showed that all the groups exhibited significantly higher fracture strength compared with the maximum bite force in the premolar region (360 N; P<0.001). The W0 group had significantly higher fracture strength than the E0 group (P<0.05). Meanwhile, no significant difference in fracture strength was observed between the E1 and W1 groups (P>0.05). Significant statistical differences were found between the zirconia ceramic groups (W0 and W1, P<0.05) but not between the glassceramic groups (E0 and E1, P>0.05) after dynamic loading. CONCLUSIONS The RBFPDs retained by all-ceramic guiding plates exhibited promising fracture properties and optimal short-term restorative effects when used to restore missing mandibular second premolars.
Collapse
Affiliation(s)
- Xin Li
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China;Nanyuan Outpatient Department, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing 210029, China
| | - Zhi-Min Zhu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Zi-Yan Li
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Jin-Ru Zhou
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Wen-Chuan Chen
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| |
Collapse
|
28
|
Nueesch R, Conejo J, Mante F, Fischer J, Märtin S, Rohr N, Blatz MB. Loading capacity of CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants with different cements. Clin Oral Implants Res 2019; 30:178-186. [PMID: 30629769 DOI: 10.1111/clr.13404] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 11/22/2018] [Accepted: 12/23/2018] [Indexed: 11/29/2022]
Abstract
OBJECTIVE This study evaluated the loading capacity of CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants with different cements. MATERIAL AND METHODS Fifty one-piece zirconia implants were embedded in epoxy resin. The abutment aspect of one implant was optically scanned and a standardized upper canine was designed with CAD-software. Fifty feldspathic ceramic crowns were milled, polished, and mounted on the implants either without any cement, with a temporary cement or with three different composite resin cements after surface pretreatment as recommended by the manufacturers (n = 10). After storage in distilled water at 37°C for 24 hr, specimens were loaded until fracture on the palatal surface of the crown at an angle of 45° to the long axis of the implant and loads until fracture were detected and compared. Compressive strength of the investigated cement materials was determined. Statistical analyses were done with One-way ANOVA followed by post hoc Fisher LSD test (α = 0.05). RESULTS The cements revealed significantly different compressive strength values (temporary cement: 37.1 ± 7.0 MPa; composite resin cements: 185.8 ± 21.3, 277.9 ± 22.1, and 389.0 ± 13.6 MPa, respectively). Load-at-fracture values had an overall mean value of 237.1 ± 58.2 N with no significant difference among the composite resin cements (p > 0.05). Fracture load values with the temporary cement or without cement were significantly lower (p < 0.002). CONCLUSIONS CAD/CAM-fabricated anterior feldspathic ceramic crowns bonded to one-piece zirconia implants provide sufficient resistance to intraoral forces.
Collapse
Affiliation(s)
- Reto Nueesch
- Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Julian Conejo
- Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, Pennsylvania
| | - Francis Mante
- Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, Pennsylvania
| | - Jens Fischer
- Division of Dental Materials and Engineering, Department of Reconstructive Dentistry, University Center for Dental Medicine, Basel, Switzerland.,VITA Zahnfabrik, Bad Säckingen, Germany
| | | | - Nadja Rohr
- Division of Dental Materials and Engineering, Department of Reconstructive Dentistry, University Center for Dental Medicine, Basel, Switzerland
| | - Markus B Blatz
- Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, Pennsylvania
| |
Collapse
|
29
|
Lopez-Suarez C, Tobar C, Sola-Ruiz MF, Pelaez J, Suarez MJ. Effect of Thermomechanical and Static Loading on the Load to Fracture of Metal-Ceramic, Monolithic, and Veneered Zirconia Posterior Fixed Partial Dentures. J Prosthodont 2018; 28:171-178. [PMID: 30548895 DOI: 10.1111/jopr.13008] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/06/2018] [Indexed: 12/01/2022] Open
Abstract
PURPOSE To evaluate the influence of static (not preloaded) and thermomechanical loading on the load to fracture of metal-ceramic, monolithic and veneered zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) posterior fixed partial dentures (FPDs). MATERIALS AND METHODS One hundred standardized specimens with 2 abutments screwed onto a platform were prepared from stainless steel to receive a posterior 3-unit FPD with an intermediate pontic. Specimens were randomly divided into 5 groups (n = 20): Metal-ceramic (control group), Lava Zirconia system, Vita In-Ceram YZ, IPS e.max ZirCAD, and Lava Plus. Half of the specimens of each group (n = 10) underwent no preloading, and the other half were subjected to thermomechanical loading in a masticatory simulator, and then all FPDs were loaded until fracture using a universal testing machine at a 1 mm/min crosshead speed. The load to fracture of the veneering ceramic and the load to fracture of framework (total fracture) were recorded for each specimen. Data were statistically analyzed using 2-way ANOVA, Tukey's HSD post-hoc test, Student's t test, and Weibull statistics, α = 0.05. RESULTS Significant differences were recorded between the metal-ceramic and veneered zirconia groups for the veneering ceramic load (p < 0.001; f = 36.62; f = 57.76) in no preloading and thermomechanical loading subgroups, respectively, but no differences were observed between the static and thermomechanical loading conditions. No differences were observed among the veneered zirconia groups. For the total load to fracture, significant differences were observed according to the material (p < 0.001; f = 500.8), between the metal-ceramic and Lava Plus group and the other zirconia groups in no preloading subgroup, and between metal-ceramic and the other groups (p < 0.001; f = 303.33) in thermomechanical loading subgroup. For the type of preloading, significant differences were observed (p = 0.02; f = 5.24) between the Lava Plus group and the other groups. Thermomechanical loading significantly decreased the fracture load of the Lava Plus group (p = 0.005). The Weibull statistics corroborated the results. CONCLUSIONS Monolithic zirconia restorations provided the highest load to fracture values among the zirconia groups tested; however, the results indicate that they must be used in the oral environment with caution, because their load to fracture was influenced by the aging simulation.
Collapse
Affiliation(s)
- Carlos Lopez-Suarez
- Department of Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Celia Tobar
- Department of Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Maria Fernanda Sola-Ruiz
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Jesus Pelaez
- Department of Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| | - Maria J Suarez
- Department of Buccofacial Prostheses, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain
| |
Collapse
|
30
|
Mahmood DJH, Braian M, Khan AS, Shabaz A, Larsson C. Fracture load of colored and non-colored high translucent zirconia three-unit fixed dental prosthesis frameworks. Acta Biomater Odontol Scand 2018; 4:38-43. [PMID: 29707612 PMCID: PMC5917306 DOI: 10.1080/23337931.2018.1459626] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Accepted: 03/28/2018] [Indexed: 11/29/2022]
Abstract
Aim: The use of colored translucent zirconia may enable restorations of a more natural tooth-like appearance than previous opaque white zirconia. The shift from non-colored to colored zirconia may however entail a risk of reduced strength. The aim of the present study was to compare fracture load and fracture mode of fixed dental prostheses frameworks made of colored translucent zirconia to that of non-colored controls. Methods: A total of forty three-unit FDP frameworks were manufactured from two different high translucent zirconia materials (Zenostar, Wieland Dental, and DD cubeX2, Dental Direkt). Each group contained two subgroups, one colored and one non-colored. Coloring was performed before final sintering using two different infiltration techniques. All FDPs underwent an artificial aging process in the form of heat treatment, thermocycling and preloading whereafter the specimens were subjected to load until fracture. Fracture load and mode was registered. Results: For one of the zirconia materials, Zenostar, the non-colored frameworks showed significantly higher fracture loads (p < .0001) compared to its colored counterpart. No significant difference (p > .05) was found between colored and non-colored frameworks in the other zirconia material, DD cubeX2. All FDPs fractured through the connector. Some fractures ran through the mesial and some through the distal side of the connector but there were no significant differences in fracture mode between groups. Conclusion: Coloring before sintering of high-translucent zirconia may decrease the fracture load of FDP frameworks for certain materials and techniques. Fracture mode however, does not appear to be affected.
Collapse
Affiliation(s)
| | - Michael Braian
- Department of Prosthetic Dentistry, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Abdul-Salam Khan
- Department of Prosthetic Dentistry, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Armin Shabaz
- Department of Prosthetic Dentistry, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Christel Larsson
- Department of Materials Science and Technology, Faculty of Odontology, Malmö University, Malmö, Sweden
| |
Collapse
|
31
|
Zaugg LK, Meyer S, Rohr N, Zehnder I, Zitzmann NU. Fracture behavior, marginal gap width, and marginal quality of vented or pre-cemented CAD/CAM all-ceramic crowns luted on Y-TZP implants. Clin Oral Implants Res 2017; 29:175-184. [PMID: 29090511 DOI: 10.1111/clr.13075] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/05/2017] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To investigate the fracture behavior and marginal gap region of CAD/CAM fabricated lithium disilicate (L) and zirconium dioxide (Z) crowns using palatal venting (PV), pre-cementation with custom analogs (CA), or conventional cementation technique (SP) with adhesive cement (A) or resin-modified glass ionomer cement (B). MATERIAL AND METHODS Twelve groups (n = 6) were set according to material (L, Z), cement (A, B), and technique (PV, CA, SP). Specimens were thermo-mechanical aged (TML), loaded until fracture (LF) and fracture patterns recorded. Marginal gap width and quality were assessed and compared to replicas obtained before and after TML. RESULTS Crown material significantly influenced LF with a mean of 1037.6 ± 282.4 N in L and 5356.3 ± 1207.0 N in Z groups (p < .001). Neither cement material nor cementation method affected the outcome. Fractures occurred along the mesial-distal central fissure in both materials. Gap width before TML was 22.04 ± 13.42 μm for L and 19.98 ± 12.72 μm for Z specimens, with overall no influence of crown material, cement type, or method. Marginal cleanliness just below the polished implant shoulder reached 66.7%-88.9% with A, and 91.7%-100% with B, and tended to increase in all groups during TML indicating a decrease in excess cement. Implant-crown junctions were cleaner with B compared to A (p ≤ .001) and along Z crown surfaces compared to L (p ≤ .007). CONCLUSIONS Crown venting of lithium disilicate and zirconium dioxide crowns did not affect the fracture load and patterns. Complete cement removal was rare, and the observed particle ablation requires further clinical attention, particularly with submucosal margins.
Collapse
Affiliation(s)
- Lucia K Zaugg
- Department of Periodontology, Endodontology and Cariology, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland.,Centre for Craniofacial and Regenerative Biology, Dental Institute, King's College London, London, UK
| | - Simon Meyer
- Department of Reconstructive Dentistry and Temporomandibular Disorders, Division of Dental Materials and Engineering, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| | - Nadja Rohr
- Department of Reconstructive Dentistry and Temporomandibular Disorders, Division of Dental Materials and Engineering, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| | - Isabella Zehnder
- Department of Periodontology, Endodontology and Cariology, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| | - Nicola U Zitzmann
- Department of Periodontology, Endodontology and Cariology, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland.,Department of Reconstructive Dentistry and Temporomandibular Disorders, Division of Dental Materials and Engineering, University Center for Dental Medicine Basel, University of Basel, Basel, Switzerland
| |
Collapse
|
32
|
Nawafleh N, Hatamleh MM, Öchsner A, Mack F. The Impact of Core/Veneer Thickness Ratio and Cyclic Loading on Fracture Resistance of Lithium Disilicate Crown. J Prosthodont 2016; 27:75-82. [PMID: 26965298 DOI: 10.1111/jopr.12473] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/29/2015] [Indexed: 11/28/2022] Open
Affiliation(s)
- Noor Nawafleh
- School of Dentistry and Oral Health, Griffith University, Queensland, Australia
| | - Muhanad M Hatamleh
- Cranio-Maxillofacial Prosthetics Unit, King's College Hospital NHS Foundation Trust, London, UK
| | - Andreas Öchsner
- School of Engineering, Griffith University, Queensland, Australia
| | - Florian Mack
- School of Dentistry and Oral Health, Griffith University, Queensland, Australia
| |
Collapse
|
33
|
Abstract
Purpose of the Study: It is difficult to achieve a reliable bond between the titanium and veneering porcelain. The aim of this study was to evaluate the bond strength between titanium ceramic crowns. Materials and Methods: The surfaces of titanium copings were divided in two groups. Group A sandblasted with 250 um (n = 10) and Group B without sandblasting (n = 10). Low-fusing porcelain was bonded over copings. A universal testing machine was used to determine the fracture load (N) of the crowns. All data were compared using Student's t-test. Results: There was a significant difference in fracture toughness between two groups (P = 0.05). The mean value of fracture strength for Group A was 721.66 N and for Group B was 396.39 N. Conclusions: Sandblasting improves the bond strength between titanium, and ceramic, mechanical bonding plays a crucial role in the bonding between titanium and ceramic.
Collapse
Affiliation(s)
- Arvind I Moldi
- Department of Prosthodontics, H.K.E.S's S.N Dental College, Gulbarga, Karnataka, India
| | - Kishor Singh Bhandari
- Department of Prosthodontics, H.K.E.S's S.N Dental College, Gulbarga, Karnataka, India
| | - Sharanbassapa Nagral
- Department of Prosthodontics, Al-Badar Rural Dental College and Hospital, Gulbarga, Karnataka, India
| | - Sumit Deshpandey
- Department of Prosthodontics, Pandit Deen Dayal Upadhyay Dental College, Solapur, Maharashtra, India
| | - Pawan Kulkarni
- Department of Prosthodontics, Al-Badar Rural Dental College and Hospital, Gulbarga, Karnataka, India
| |
Collapse
|
34
|
Kohal RJ, Kilian JB, Stampf S, Spies BC. All-Ceramic Single Crown Restauration of Zirconia Oral Implants and Its Influence on Fracture Resistance: An Investigation in the Artificial Mouth. Materials (Basel) 2015; 8:1577-1589. [PMID: 28788018 PMCID: PMC5507023 DOI: 10.3390/ma8041577] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Revised: 03/20/2015] [Accepted: 03/27/2015] [Indexed: 11/30/2022]
Abstract
The aim of the current investigation was to evaluate the fracture resistance of one-piece zirconia oral implants with and without all-ceramic incisor crowns after long-term thermomechanical cycling. A total of 48 implants were evaluated. The groups with crowns (C, 24 samples) and without crowns (N, 24 samples) were subdivided according to the loading protocol, resulting in three groups of 8 samples each: Group “0” was not exposed to cyclic loading, whereas groups “5” and “10” were loaded with 5 and 10 million chewing cycles, respectively. This resulted in 6 different groups: C0/N0, C5/N5 and C10/N10. Subsequently, all 48 implants were statically loaded to fracture and bending moments were calculated. All implants survived the artificial aging. For the static loading the following average bending moments were calculated: C0: 326 Ncm; C5: 339 Ncm; C10: 369 Ncm; N0: 339 Ncm; N5: 398 Ncm and N10: 355 Ncm. To a certain extent, thermomechanical cycling resulted in an increase of fracture resistance which did not prove to be statistically significant. Regarding its fracture resistance, the evaluated ceramic implant system made of Y-TZP seems to be able to resist physiological chewing forces long-term. Restauration with all-ceramic single crowns showed no negative influence on fracture resistance.
Collapse
Affiliation(s)
- Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Center for Dental Medicine, University Hospital Freiburg, Albert-Ludwigs-University, Freiburg 79106, Germany.
| | | | - Susanne Stampf
- Department for Medical Biometry and Medical Informatics, Institute for Medical Biometry and Statistics, Albert-Ludwigs-University, Freiburg 79104, Germany.
| | - Benedikt Christopher Spies
- Department of Prosthetic Dentistry, Center for Dental Medicine, University Hospital Freiburg, Albert-Ludwigs-University, Freiburg 79106, Germany.
| |
Collapse
|
35
|
Schwindling FS, Hartmann T, Panagidis D, Krisam J, Rues S, Schmitter M. In vitro investigation on extensively destroyed vital teeth: is fracture force a limiting factor for direct restoration? J Oral Rehabil 2014; 41:920-7. [PMID: 25155353 DOI: 10.1111/joor.12219] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/31/2014] [Indexed: 11/26/2022]
Abstract
To evaluate the in vitro fracture load of extensively damaged vital teeth after either direct or indirect restauration, severe tooth substance loss was simulated for 96 molars. Subsequently, two cavities were prepared with little (design 1) or more substantial (design 2) residual tooth support. All molars were provided with a 2-mm ferrule design and then divided into 12 test groups based on their occlusal surface size. They were restored with composite or with either of two types of single crown (cast metal or milled zirconia). After thermal ageing (10,000 cycles at 6.5 and 60 °C), 1.2 million cycles of chewing simulation were applied (64 N). Maximum fracture load was determined with a loading angle of 45°. Statistical analysis was performed by use of Kaplan-Meier modelling, Student's t-tests, one-way anova, post hoc Tukey's HSD tests and linear regression analysis. Regarding mean fracture load without ageing, the indirect restorations outperformed composite (design 1: direct: 508 ± 123 N, indirect: 741 ± 248 N; design 2: direct: 554 ± 167 N, indirect: 903 ± 221 N). After artificial ageing, however, these differences were no longer significant (design 1: direct: 328 ± 189 N, indirect: 506 ± 352 N; design 2: direct 399 ± 208 N, indirect 577 ± 292 N). Instead, the fracture load of the aged composite restorations was comparable with that for zirconia (design 1) and cast metal (design 2) crowns. Fracture loads of direct composite restorations after artificial ageing might fulfil clinical requirements.
Collapse
Affiliation(s)
- F S Schwindling
- Department of Prosthodontics, University Hospital Heidelberg, Heidelberg, Germany
| | | | | | | | | | | |
Collapse
|
36
|
Spohr AM, Borges GA, Platt JA. Thickness of immediate dentin sealing materials and its effect on the fracture load of a reinforced all-ceramic crown. Eur J Dent 2014; 7:474-483. [PMID: 24932124 PMCID: PMC4053674 DOI: 10.4103/1305-7456.120682] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Objectives: The objective of this study is to evaluate, in vitro, the thickness of immediate dentin sealing (IDS) materials on full crown preparations and its effect on the fracture load of a reinforced all-ceramic crown. Materials and Methods: Sixty premolars received full crown preparation and were divided into the following groups according to the IDS technique: G1-control; G2-Clearfil SE Bond; and G3-Clearfil SE Bond and Protect Liner F. After the impressions were taken, the preparations were temporized with acrylic resin crowns. IPS empress 2 restorations were fabricated and later cemented on the preparations with Panavia F. 10 specimens from each group were submitted to fracture load testing. The other 10 specimens were sectioned buccolingually before the thicknesses of Panavia F, Clearfil SE Bond and Protect Liner F were measured in 10 different positions using a microscope. Results: According to analysis of variance and Tukey's test, the fracture load of Group 3 (1300 N) was significantly higher than that of Group 1 (1001 N) (P < 0.01). Group 2 (1189 N) was not significantly different from Groups 1 and 3. The higher thickness of Clearfil SE Bond was obtained in the concave part of the preparation. Protect Liner F presented a more uniform range of values at different positions. The thickness of Panavia F was higher in the occlusal portion of the preparation. Conclusions: The film thickness formed by the IDS materials is influenced by the position under the crown, suggesting its potential to increase the fracture load of the IPS empress 2 ceramic crowns.
Collapse
Affiliation(s)
- Ana Maria Spohr
- Department of Dental Materials, Pontifical Catholic University of Rio Grande do Sul, Brazil
| | - Gilberto Antonio Borges
- Department of Dental Materials and Restorative Dentistry, University of Uberaba, Minas Gerais, Brazil
| | - Jeffrey A Platt
- Department of Restorative Dentistry, Division of Dental Biomaterials, Indiana University School of Dentistry, Indianapolis, IN, USA
| |
Collapse
|
37
|
Morishima T, Ginsel BL, Choy GGH, Wilson LJ, Whitehouse SL, Crawford RW. Periprosthetic fracture torque for short versus standard cemented hip stems: an experimental in vitro study. J Arthroplasty 2014; 29:1067-71. [PMID: 24295802 DOI: 10.1016/j.arth.2013.10.016] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2013] [Revised: 10/16/2013] [Accepted: 10/17/2013] [Indexed: 02/01/2023] Open
Abstract
In an attempt to preserve proximal femoral bone stock and achieve a better fit in smaller femora, especially in the Asian population, several new shorter stem designs have become available. We investigated the torque to periprosthetic femoral fracture of the Exeter short stem compared with the conventional length Exeter stem in a Sawbone model. Forty-two stems; 21 shorter and 21 conventional stems both with three different offsets were cemented in a composite Sawbone model and torqued to fracture. Results showed that Sawbone femurs break at a statistically significantly lower torque to failure with a shorter compared to conventional-length Exeter stem of the same offset. Both standard and short-stem designs are safe to use as the torque to failure is 7-10 times that seen in activities of daily living.
Collapse
Affiliation(s)
- Takkan Morishima
- Institute of Health and Biomedical Innovation, Queensland University of Technology, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | - Bastiaan L Ginsel
- Institute of Health and Biomedical Innovation, Queensland University of Technology, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | - Godwin G H Choy
- Institute of Health and Biomedical Innovation, Queensland University of Technology, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | - Lance J Wilson
- Institute of Health and Biomedical Innovation, Queensland University of Technology, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | - Sarah L Whitehouse
- Institute of Health and Biomedical Innovation, Queensland University of Technology, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | - Ross W Crawford
- Institute of Health and Biomedical Innovation, Queensland University of Technology, The Prince Charles Hospital, Brisbane, Queensland, Australia
| |
Collapse
|
38
|
Krishna VP, Premalatha A, Babu PJ, Raju DS, Kumar MP, Rao DB. Effect of various chemicals on the bond strength of acrylic tooth and denture base -An Invitro comparative study. J Int Oral Health 2014; 6:100-105. [PMID: 24653612 PMCID: PMC3959146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2013] [Accepted: 12/09/2013] [Indexed: 06/03/2023] Open
Abstract
BACKGROUND Debonding of acrylic teeth from the denture base is a common problem. Certain clinical conditions like ridge prominence leads to excess trimming of acrylic teeth and base, resulting in a weak interface. The denture base polymer debonds adhesively in the region of the highly cross -linked matrix of the teeth. To compare the effect of different chemical surface treatments on the bond between cross-linked acrylic teeth and different types of denture base material. MATERIALS & METHODS A total of 180 wax specimens were fabricated and divided into 3 groups: Heat-cure, high impact heat-cure, flexible denture base material bonded to acrylic teeth. Each group was further subdivided into 6 subgroups with 10 specimens each according to the surface treatment ofthe ridge lap area: control, monomer, acetone 99%, chloroform 99%, acrylic adhesive cyanoacrylate, ethyl acetate 99%. After processing, specimens were tested for bond strength using a universal testing machine. The resulting bond strengths were recorded, statistically analyzed and compared. RESULTS Among all the 3types of denture base resins, highimpact heat-cure denture base resin gave highest bond strength. There was no bonding of teeth with flexible denture base material. Chemical surface treatment of acrylic teeth with ethyl acetate gave highest bond strength followed by control, chloroform, acetone and cyanoacrylate groups. CONCLUSION Among all the 3types of denture base materials, high-impact heat-cure denture base resin gave highest bond strength with ethyl acetate surface treatment. Simple and quick tooth chemical surface treatment with ethylacetate could be an effective option in decreasing bonding failures and also avoid repeated denture repairs improving patient satisfaction. How to cite the article: Krishna VP, Premalatha A, Babu PJ, Raju DS, Kumar MP, Rao DB. Effect of various chemicals on the bond strength of acrylic tooth and denture base -An In-vitro comparative study. J Int Oral Health 2014;6(1):100-5.
Collapse
Affiliation(s)
- V Pridhvi Krishna
- Department of Prosthodontics, MNR Dental College, Sangareddy, Andhra Pradesh, India
| | - Averneni Premalatha
- Department of Prosthodontics, Dr. Sudha & Nageswara Rao Siddhartha Institute of Dental Sciences, Chinnaoutpalli, Gannavaram, Andhra Pradesh, India
| | - P Jithendra Babu
- Department of Prosthodontics, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India
| | - D Srinivasa Raju
- Department of Prosthodontics, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India
| | - M Praveen Kumar
- Department of Prosthodontics, MNR Dental College, Sangareddy, Andhra Pradesh, India
| | | |
Collapse
|