1
|
P MK, Nagate RR, Chaturvedi S, Al-Ahmari MMM, Al-Qarni MA, Gokhale ST, Ahmed AR, Bariqi AA, Cicciù M, Minervini G. Importance of periodontal phenotype in periodontics and restorative dentistry: a systematic review. BMC Oral Health 2024; 24:41. [PMID: 38191372 PMCID: PMC10773067 DOI: 10.1186/s12903-023-03777-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 12/14/2023] [Indexed: 01/10/2024] Open
Abstract
BACKGROUND Periodontal phenotype is regarded to be one of the key factors influencing the efficacy of restorative therapies in dental practice. The objective of the systematic review was to explore the importance of thin and thick periodontal phenotypes and how they affect the outcome of periodontal and restorative therapies by looking at a number of academic publications from various online databases. METHODS Following the PRISMA guidelines (Preferred Reporting Items for Systematic Review standards), relevant data will be searched and retrieved from three significant scientific databases, including PubMed, EBSCO, and Scopus. The articles with full texts that matched the keywords and published in English between 2018 and 2023 were taken into consideration. RESULTS The majorities of these articles were based on the type of periodontal phenotype and their impact on periodontal and restorative treatment outcomes were selected. The initial search yielded a total of 530 articles. Only 273 were relevant to the review's objectives, and these were considered for determining eligibility. Only 20 publications were eligible for analysis. CONCLUSION Understanding these anatomical aspects of periodontal phenotype is crucial to both periodontology and restorative dentistry. The clinical outcome of restorative, prosthetic, orthodontic, surgical, and periodontal therapies is determined in large part by the periodontal phenotype, which also plays a significant role in clinical failure or success in dental treatments. TRIAL REGISTRATION This study protocol registered with the International Prospective Register of Systematic Reviews (PROSPERO) dated 16th June 2023 with the registration ID CRD42023432568.
Collapse
Affiliation(s)
- Mohan Kumar P
- Department of Periodontics and Implantology, Vishnu Dental College, West Godavari, Vishnupur, Bhimavaram, 534202, Andhra Pradesh, India.
| | - Raghavendra Reddy Nagate
- Department of Periodontics and Community Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Saurabh Chaturvedi
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
| | - Manae Musa Musleh Al-Ahmari
- Department of Periodontics and Community Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Mohammed A Al-Qarni
- Consultant in Restorative Dentistry, College of Dentistry, King Khalid University, P.O.Box 3263, Abha, 61471, Saudi Arabia
| | - Shankar T Gokhale
- Department of Periodontics and Community Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Abdul Razzaq Ahmed
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Ahmed Al Bariqi
- Department of Periodontics and Community Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Marco Cicciù
- Department of Biomedical and Surgical and Biomedical Sciences, Catania University, Catania, 95123, Italy
| | - Giuseppe Minervini
- Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Chennai, Tamil Nadu, India.
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania "Luigi Vanvitelli", Caserta, 81100, Italy.
| |
Collapse
|
2
|
Alghazzawi TF. A Comparison of Failure Loads for Polycrystalline Zirconia Ceramics with Varying Amounts of Yttria, Glass-Ceramics and Polymers in Two Different Test Conditions. Polymers (Basel) 2023; 15:4506. [PMID: 38231917 PMCID: PMC10708478 DOI: 10.3390/polym15234506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/14/2023] [Accepted: 11/21/2023] [Indexed: 01/19/2024] Open
Abstract
It is unclear how zirconia dental crowns with different yttria compositions will perform clinically, and how they will compare with crowns made of glass-ceramics and polymers. The present objective was to determine failure loads of crowns and discs made of glass ceramics or polymers as compared to yttria-partially stabilized zirconia (Y-PSZ) crowns and discs with varying yttria concentrations. Crowns of zirconia (Cercon XT, Katana UTML, BruxZir Anterior), glass ceramic (Celtra press, IPS e.max press, Lisi press), and polymeric materials (Trilor, Juvora, Pekkton) were fabricated and cemented to epoxy abutments. The total number of specimens was 135 for crowns and 135 for discs (n = 15 specimens per material type and design). A universal testing machine was used to perform compressive loading of crowns/discs to failure with a steel piston along the longitudinal axis of the abutments. Energy dispersive spectroscopy (EDS) was used to identify the yttria concentration for each zirconia brand. The data were analyzed using generalized linear models and regression analyses. The results revealed significant differences (p < 0.05) in mean failure loads for different crown materials: Trilor (6811 ± 960 N) > Juvora (5215 ± 151 N) > Cercon (4260 ± 520 N) = BruxZir (4186 ± 269 N) = e.max (3981 ± 384 N) > Katana (3195 ± 350 N) = Lisi (3173 ± 234 N) = Pekkton (3105 ± 398 N) > Celtra (2696 ± 393 N). The general linear model revealed significant differences (p < 0.05) in mean failure loads when comparing the different materials for the discs, i.e., Trilor (5456 ± 1748 N) > Juvora (4274 ± 869 N) > Pekkton (3771 ± 294 N) > Katana (2859 ± 527 N) > Cercon (2319 ± 342 N) = BuxZir (2250 ± 515 N) = e.max (2303 ± 721 N) = Lisi (2333 ± 535 N) > Celtra (1965 ± 659 N). EDS showed that the zirconia materials contained yttria at different concentrations (BruxZir = 5Y-PSZ, Cercon = 4Y-PSZ, Katana = 3Y-PSZ). The yttria concentration had a significant effect on the failure load of the Katana (3Y-PSZ) crowns, which revealed lower failure loads than the Cercon (4Y-PSZ) and BruxZir (5Y-PSZ) crowns, whose failure loads were comparable or higher than e.max glass ceramic. The failure load of the trilayer disc specimens did not correlate with the failure load of the respective crown specimens for the zirconia, glass-ceramic and polymeric materials.
Collapse
Affiliation(s)
- Tariq F. Alghazzawi
- Department of Substitutive Dental Sciences, Taibah University, Madinah 42353, Saudi Arabia;
- Department of Mechanical and Materials Engineering, The University of Alabama at Birmingham, Birmingham, AL 35294, USA
| |
Collapse
|
3
|
Gad MM, Alalawi H, Akhtar S, Al-Ghamdi R, Alghamdi R, Al-Jefri A, Al-Qarni FD. Strength and Wear Behavior of Three-Dimensional Printed and Prefabricated Denture Teeth: An In Vitro Comparative Analysis. Eur J Dent 2023; 17:1248-1256. [PMID: 36669653 PMCID: PMC10756787 DOI: 10.1055/s-0042-1759885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
OBJECTIVES With advanced technology for complete denture fabrication, there is a lack of knowledge on the mechanical behavior of three-dimensional (3D) printed teeth despite the development of complete denture fabrication technologies. This study aimed to compare different types of 3D-printed teeth in terms of wear and fracture resistance in comparison to control prefabricated denture teeth. MATERIALS AND METHODS One prefabricated tooth was selected and fixed in a resin holder and half of the tooth remained in anatomic form, while the other half was flattened for the wear test. One from each type was scanned and then printed with different resins; Asiga (DentaTOOTH, Asiga, Alexandria 2015,NSW, Australia), FormLabs (Denture Base LP, FormLabs, Berlin, Germany), and NextDent (NextDent C&B MFH, NextDent B.V., Soesterberg, the Netherlands) according to manufacturer recommendations. A total of 60 specimens (20/resin, n = 10) were thermo cycled (5,000 cycles) and wear test samples were further subjected to cyclic loading (1,70,000 cycles) in a chewing simulator machine CS-4.2 (SD Mechatronik GmbH, Germany). The fracture strength of anatomic teeth was measured using a universal testing machine (Instron model 5965, Massachusetts, United States), while Geomagic Control X software was used to assess the amount of wear of flattened teeth. Statistical analyses were performed with one-way analysis of variance with Tukey's post hoc test at significance level of α = 0.05. RESULTS NextDent specimens showed the greatest volume loss, whereas FormLabs specimens showed the least volume loss. Comparing NextDent specimens to FromLabs specimens, FromLabs showed statistically significantly less volume loss (p < 0.001). No other group pairs differed significantly from one another in terms of volume loss (p > 0.06). CONCLUSION 3D-printed denture teeth showed comparable strength and wear resistance with the prefabricated denture teeth and were suitable for long-term clinical usage except for NextDent that significantly showed the lowest fracture resistance.
Collapse
Affiliation(s)
- Mohammed M. Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Haidar Alalawi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Raghad Al-Ghamdi
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Rahaf Alghamdi
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Alaa Al-Jefri
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Faisal D. Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| |
Collapse
|
4
|
Kongkiatkamon S, Rokaya D, Kengtanyakich S, Peampring C. Current classification of zirconia in dentistry: an updated review. PeerJ 2023; 11:e15669. [PMID: 37465158 PMCID: PMC10351515 DOI: 10.7717/peerj.15669] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 06/09/2023] [Indexed: 07/20/2023] Open
Abstract
Zirconia, a crystalline oxide of zirconium, holds good mechanical, optical, and biological properties. The metal-free restorations, mostly consisting of all-ceramic/zirconia restorations, are becoming popular restorative materials in restorative and prosthetic dentistry choices for aesthetic and biological reasons. Dental zirconia has increased over the past years producing wide varieties of zirconia for prosthetic restorations in dentistry. At present, literature is lacking on the recent zirconia biomaterials in dentistry. Currently, no article has the latest information on the various zirconia biomaterials in dentistry. Hence, the aim of this article is to present an overview of recent dental zirconia biomaterials and tends to classify the recent zirconia biomaterials in dentistry. This article is useful for dentists, dental technicians, prosthodontists, academicians, and researchers in the field of dental zirconia.
Collapse
Affiliation(s)
- Suchada Kongkiatkamon
- Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| | - Dinesh Rokaya
- Faculty of Dentistry, Zarqa University, Zarqa, Jordan
| | - Santiphab Kengtanyakich
- Prosthodontic Section, Department of Restorative Dentistry, Naresuan University, Phitsanulok, Thailand
| | - Chaimongkon Peampring
- Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| |
Collapse
|
5
|
Gavara SG, Jain S, Gupta H, Sharma S, Panwar P, Momin MS. Comparative Effect of No Finish Line, Heavy Chamfer, and Shoulder Marginal Designs on the Fracture Resistance of Zirconia (Cercon) Ceramic Restoration: An In Vitro Study. Cureus 2023; 15:e39009. [PMID: 37323304 PMCID: PMC10264088 DOI: 10.7759/cureus.39009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 05/14/2023] [Indexed: 06/17/2023] Open
Abstract
Background Because all-ceramic crowns are more aesthetic and biocompatible than metal-ceramic crowns, they have grown in popularity among patients and dentists. Poor finish line layout can result in restoration margin fracturing, hence, finish line arrangement is critical to maintaining the restoration's marginal integrity. The goal of this in-vitro study is to evaluate zirconia's resistance to fracture (Cercon) ceramic restorations with three marginal designs (no finish line, heavy chamfer, and shoulder). This study is important in contributing to the ongoing debate about the optimal finish line design for zirconia restorations. Methodology Three different finish lines, namely, biologically oriented preparation technique (BOPT) with a marginal width of less than 0.3 mm, heavy chamfer with a marginal width of up to 0.3 mm, and shoulder with a marginal width greater than 0.3 mm, were made on 10 extracted maxillary first premolar tooth to make 30 epoxy resin dies on which zirconia (Cercon) coping was done using CAD/CAM technology, and marginal discrepancies were measured using a three-dimensional scanner. All the copings were affixed to their respective dies using GIC luting cement, and fracture resistance was measured using a digital universal testing machine. Results The Kruskal-Wallis test revealed that the mean fracture resistance was more in the heavy chamfer finish line, followed by the no finish line (BOPT) and the shoulder finish line. No statistically significant difference was seen between the no finish line and the heavy chamfer finish line. There was a significant difference between the heavy chamfer and shoulder finish lines (p = 0.004). Conclusions To increase the biomechanical performance of posterior single zirconia restorations, heavy chamfer margins are indicated.
Collapse
Affiliation(s)
- Sai Govind Gavara
- Department of Prosthodontics, Crown and Bridge and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sriganganagar, IND
| | - Shashikala Jain
- Department of Prosthodontics, Crown and Bridge and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sriganganagar, IND
| | - Himanshu Gupta
- Department of Prosthodontics, Crown and Bridge and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sriganganagar, IND
| | - Suraj Sharma
- Department of Prosthodontics, Crown and Bridge and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sriganganagar, IND
| | - Pratibha Panwar
- Department of Prosthodontics, Crown and Bridge and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sriganganagar, IND
| | - Mariyam S Momin
- Department of Periodontics and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sriganganagar, IND
| |
Collapse
|
6
|
Oyar P, Durkan R. The effects of heating rate and sintering time on the biaxial flexural strength of monolithic zirconia ceramics. BIOMED ENG-BIOMED TE 2023:bmt-2022-0338. [PMID: 36930871 DOI: 10.1515/bmt-2022-0338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Accepted: 03/02/2023] [Indexed: 03/19/2023]
Abstract
The strength of zirconia ceramic materials used in restorations is dependent upon sintering. Varying sintering protocols may affect the biaxial flexural strength of zirconia materials. This in vitro study was conducted to investigate the effects of sintering parameters on the biaxial flexural strength of monolithic zirconia. Two different monoblock zirconia ceramics were used. Following coloration, samples of both types of ceramics were divided into groups according to whether or not biaxial flexural strength testing was performed directly after sintering or following thermocycling. Biaxial flexural strength data was analysed with a Shapiro Wilk normality test, followed by 1-way ANOVA, Tukey post hoc tests for inter-group comparisons, and paired samples t-tests for intra-group comparisons. A significant difference was found between the biaxial flexural strengths of Zircon X and Upcera ceramics before thermocycling (p<0.05). In both Zircon X and Upcera ceramic groups, the thermocycling process created a significant difference in the biaxial flexural strength values of the ceramic samples in Group 6 (p<0.05) which had the slowest heating rate and longest holding time. The zirconia ceramics have higher BFS at higher heating rates either before or after thermocycling. The holding time has significant effects on thermocycling and flexural strength. The zirconia achieved its optimum strength when it sintered at longer time regardless of heating rates.
Collapse
Affiliation(s)
- Perihan Oyar
- Professor, Dental Prosthetics Technology, Vocational School of Health Services, Hacettepe University, Ankara, Türkiye
| | - Rukiye Durkan
- Department of Prosthodontics, Faculty of Dentistry, Istanbul Okan University, Istanbul, Türkiye
| |
Collapse
|
7
|
Alghazzawi TF, Janowski GM, Ning H, Eberhardt AW. Qualitative SEM analysis of fracture surfaces for dental ceramics and polymers broken by flexural strength testing and crown compression. J Prosthodont 2023. [PMID: 36739572 DOI: 10.1111/jopr.13659] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 01/22/2023] [Indexed: 02/06/2023] Open
Abstract
PURPOSE To perform qualitative analysis using scanning electron microscopy (SEM) of fracture surfaces for ceramic and polymeric dental materials broken via standardized flexural and crunch-the-crown (CTC) tests. MATERIALS AND METHODS Zirconia, glass-ceramic, and polymeric (Trilor; TRI, Juvora; JUV, Pekkton; PEK) materials were loaded using crowns for CTC tests, discs (zirconia and glass-ceramics) for piston-on-3 ball tests, bars (polymer) for 3-point bend tests, and bars (zirconia, glass-ceramics) for 4-point bend tests. SEM was used to characterize the fracture surfaces and identify fracture surface features (e.g., origin, mist, hackle, and the direction of crack propagation [DCP]). Electron dispersive spectroscopy was used to identify the local chemistry. RESULTS Fracture surface features were found to be less visually apparent for glass-ceramics than zirconia. For zirconia bars, fractures originated roughly midway between the corner and center for processing defects related to sintering. Fractures originated at the bottom corners of glass-ceramic bars (void or surface flaw) and PEK bars (surface flaw). TRI bar failures exposed glassy fibers. Fracture features were generally less discernable for discs compared to bars for zirconia and glass-ceramics. Ceramic crowns fractured into 2 to 3 pieces, with fractures originating at the occlusal surface and clear evidence for the DCP. Failures of TRI and JUV specimens (bars and crowns) were less catastrophic than for the ceramics, with exposed fibers (TRI) and surface cracks (JUV). PEK crown and bar fractures presented dimple (ductile) features formed due to microvoid coalescence followed by brittle crack propagation. CONCLUSIONS The critical flaws responsible for failure initiation were a function of material composition and test configuration. Fractographic analysis can reveal problems associated with the manufacturing of materials, their handling, grinding and finishing/polishing procedures, the structural design and choice of material, and the quality of the final laboratory-delivered restoration.
Collapse
Affiliation(s)
- Tariq F Alghazzawi
- Department of Substitutive Dental Sciences, Taibah University, Madina, Saudi Arabia.,Department of Mechanical and Materials Engineering, The University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Gregg M Janowski
- Department of Mechanical and Materials Engineering, The University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Haibin Ning
- Department of Mechanical and Materials Engineering, The University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Alan W Eberhardt
- Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, Alabama, USA
| |
Collapse
|
8
|
El Shahawy OI, Azab MM. Fracture resistance of prefabricated versus custom-made zirconia crowns after thermo-mechanical aging: an in-vitro study. BMC Oral Health 2022; 22:587. [PMID: 36494637 PMCID: PMC9733029 DOI: 10.1186/s12903-022-02628-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Accepted: 11/29/2022] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Prefabricated zirconia crowns for a young permanent molar is a child-friendly solution for restoring a permanent molar at a young age. This in-vitro study aimed to compare the fracture resistance of prefabricated versus custom-made permanent molar crowns. METHODS 16 identical resin dies were fabricated to receive permanent molar zirconia crowns, dies were divided into 2 groups, 1) received perfricated crowns, 2) custom-made crowns. Thermo-dynamic cycling was performed to simulate 6 months in the oral cavity, Fracture resistance of each group was assessed by applying increasing load till fracture. Data were tested for normality using Shapiro-Wilk and Levene's tests. Data were analyzed using independent t test. RESULTS No statistically significant difference was found between fracture resistance of prefabricated and custom-made crowns (1793.54 ± 423.82) and (1987.38 ± 414.88) respectively. 3 crowns of the custom-made group fractured with the underlying die, versus zero dies fractured in the prefabricated group. CONCLUSIONS Prefabricated permanent molars zirconia crowns can perform as well as custom-made crowns for an adult in terms of fracture resistance, it is suitable for children and can withstand the occlusal forces of an adult.
Collapse
Affiliation(s)
- Osama Ibrahim El Shahawy
- grid.7776.10000 0004 0639 9286Department of Pediatric Dentistry, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Maha Moussa Azab
- grid.411170.20000 0004 0412 4537Department of Pediatric Dentistry, Faculty of Dentistry, Fayoum University, Fayoum, Egypt ,grid.517528.c0000 0004 6020 2309Department of Pediatric Dentistry, School of Dentistry, Newgiza University NGU, Giza, Egypt
| |
Collapse
|
9
|
Kongkiatkamon S, Peampring C. Comparison of Regular and Speed Sintering on Low-Temperature Degradation and Fatigue Resistance of Translucent Zirconia Crowns for Implants: An In Vitro Study. J Funct Biomater 2022; 13:jfb13040281. [PMID: 36547541 PMCID: PMC9785840 DOI: 10.3390/jfb13040281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 11/22/2022] [Accepted: 12/04/2022] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Although there are a few studies which compare fast and slow sintering in normal zirconia crowns, it is essential to compare the cracks and load-bearing capacity in zirconia screw-retained implant crowns between regular and speed sintering protocols. This research aimed to compare the surface structure, cracks, and load-bearing capacity in zirconia screw-retained implant crowns between regular sintering (RS) and speed sintering (SS) protocol with and without cyclic loading (fatigue). METHODS A total of 60 screw-retained crowns were fabricated from zirconia (Katana STML Block) by the CAD/CAM system. Then, 30 crowns were subjected to the RS protocol and 30 crowns were subjected to the SS protocol. Cyclic loading was done in half zirconia crowns (15 crowns in each group) using a chewing simulator CS-4.8/CS-4.4 at room temperature. The loading force was applied on the middle of the crowns by a metal stylus underwater at room temperature with a chewing simulator at an axial 50 N load for 240,000 cycles and lateral movement at 2 mm. Scanning electron microscopy was done to study the surface of the crowns and the cracks in the crowns of the regular and speed sintering protocols, with and without fatigue. RESULTS For the speed sintering group, the surface looks more uniform, and the crack lines are present at a short distance compared to regular sintering. The sintering protocol with a larger Weibull module and durability increases the reliability. It showed that the Speed group showed the maximum fracture load, followed by the regular, speed fatigue, and regular fatigue groups. The fracture load in various groups showed significant differences. CONCLUSIONS It was found that the speed group showed the maximum fracture load followed by the regular, speed fatigue, and regular fatigue. The crack lines ran from occlusal to bottoms (gingiva) and the arrest lines were perpendicular to the crack propagations.
Collapse
|
10
|
Güleç C, Sarıkaya I. The influence of aging on the fracture load of milled monolithic crowns. BMC Oral Health 2022; 22:516. [PMCID: PMC9675227 DOI: 10.1186/s12903-022-02529-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 10/24/2022] [Indexed: 11/21/2022] Open
Abstract
Background This in-vitro study was conducted to assess the effect of aging on the fracture load of molar crowns fabricated with monolithic CAD/CAM materials. Methods The crown restorations were produced from Cerasmart, Vita Enamic, and IPS e.max CAD blocks. Aging was applied to the 10 samples each of monolithic CAD/CAM materials (n = 10). Dual-axis chewing simulator (50 N, 1.1 Hz, lateral movement: 1 mm, mouth opening: 2 mm, 1,200,000 cycles) and thermocycling (± 5–55 °C, 6000 cycles) were applied as an aging procedure. 10 samples each of monolithic CAD/CAM materials without aging (n = 10) were considered the control group. 6 tested groups were obtained. Then, all samples were evaluated in a universal testing machine to determine the fracture loading values’. Results There was not a statistically significant difference between the fracture load values before and after aging for all samples of Cerasmart, Vita Enamic, and IPS e.max CAD (p > 0.005). In a comparison of the monolithic materials together, a statistically significant difference was found between the fracture load values of IPS e.max CAD and Vita Enamic crowns before aging (p = 0.02). Also, Vita Enamic crowns (1978,71 ± 364,05 N) were found different from the IPS e.max CAD (p = 0.005) and Cerasmart crowns (p = 0.041) after aging. Conclusions Dynamic aging with 1.200.000 cycles was found to have no effect to fracture loading on milled Cerasmart, Vita Enamic, and IPS e.max CAD monolithic crowns.
Collapse
Affiliation(s)
- Ceyda Güleç
- grid.411550.40000 0001 0689 906XDepartment of Prosthodontics, Faculty of Dentistry, Tokat Gaziosmanpasa University, Ali Şevki Erek Campus, 60100 Tokat, Turkey
| | - Işıl Sarıkaya
- grid.411550.40000 0001 0689 906XDepartment of Prosthodontics, Faculty of Dentistry, Tokat Gaziosmanpasa University, Ali Şevki Erek Campus, 60100 Tokat, Turkey
| |
Collapse
|
11
|
Kongkiatkamon S, Peampring C. Effect of Speed Sintering on Low Temperature Degradation and Biaxial Flexural Strength of 5Y-TZP Zirconia. Molecules 2022; 27:molecules27165272. [PMID: 36014509 PMCID: PMC9416714 DOI: 10.3390/molecules27165272] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 08/03/2022] [Accepted: 08/15/2022] [Indexed: 11/16/2022] Open
Abstract
Translucent zirconia is becoming the material of choice for the esthetic restorative material. We aimed to evaluate the surface structure, phase determination, translucency, and flexural strength of 5Y-TZP Zirconia (Katana STML Block and Disc) between the regular sintering and the speed sintering with and without low-temperature degradation (LTD). A total of 60 zirconia discs (30 per group; regular sintering and speed sintering) were used in this study. A CAM machine was used to mill cylinders out of the zirconia blanks and then cut into smaller discs. For the speed sintering, the zirconia blocks were milled into smaller discs. The zirconia discs were subjected to regular and speed sintering with and without LTD. Scanning electron microscopy was used to characterize the zirconia specimens and the zirconia grain size. Furthermore, the zirconia specimens were analyzed for elemental analysis using energy dispersive spectroscopy and phase identification using X-ray diffraction. The zirconia specimens were subjected to translucency measurements and biaxial flexural strength testing. The results of the zirconia specimens were compared among the groups. Statistical analysis was completed using SPSS version 20.0 to detect the statistically significant differences (p value = 0.05). A one-way ANOVA with multiple comparisons was performed using Scheffe analysis among the groups. The speed sintering presented smaller grain sizes. The zirconia specimens with and without LTD in regular and speed sintering presented a similar surface structure. Regular sintering showed more translucency compared to speed sintering. Multiple comparisons of the translucency parameter were a significant difference (p value < 0.05) between the various groups except for the comparison between speed sintering and speed sintering LTD. The regular sintering showed bigger gain sizes and slightly more translucency compared to speed sintering. The speed sintering showed higher biaxial flexural strengths compared to regular sintering. This shows that speed sintering can be considered a suitable method of sintering zirconia.
Collapse
|
12
|
Kongkiatkamon S, Rokaya D. Full Digital Workflow in the Esthetic Dental Restoration. Case Rep Dent 2022; 2022:8836068. [PMID: 35762014 DOI: 10.1155/2022/8836068] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 05/31/2022] [Accepted: 06/04/2022] [Indexed: 12/23/2022] Open
Abstract
This case report presented a fully digital workflow in esthetic dental restoration. A 51-year-old female patient was referred to BDMS Wellness Clinic due to a fracture of the maxillary left central incisor. An immediate dental implant was planned to restore tooth 21 with esthetic crown lengthening of upper front teeth and new zirconia crowns for teeth 11, 12, 13, 21, 22, and 23. Digital impression was made using a digital scanner (PRIMESCAN®, Dentsply Sirona, Bensheim, Germany); surgical guide (Cerec Guide 3, Dentsply Sirona, Bensheim, Germany) was designed by using a designing software (Galileos Software, Dentsply Sirona, Bensheim, Germany) and was milled by using a milling machine (MCXL milling machine, Dentsply Sirona, Bensheim, Germany) to create a precise surgical guide. 3D smile design was done by using the Digital Smile Design (DSD) program, the crown lengthening guide was designed according to DSD designed by using a designing software (Inlab 19 Software, Dentsply Sirona, Bensheim, Germany), and the guide was fabricated by a 3D printer (FormLabs Form 2, Formlab, MA, USA). Provisional crowns (splinted) for teeth 11, 12, 13, 21, 22, and 23 were milled by using polymer (VIPI BLOCK TRILUX®, VIPI Industria, Pirassununga, SP, Brazil) using a milling machine (MCX5, Dentsply Sirona, Bensheim, Germany). The zirconia crowns were designed by using software (Inlab19 Software, Dentsply Sirona, Bensheim, Germany) and milled using the same milling machine. At the implant position, Ti-base is cemented by using an abutment (Multilink Hybrid Abutment, Ivoclar Vivadent, Schaan, Lichtenstein, Germany) with zirconia coping (Cercon base white shade, Dentsply Sirona, Bensheim, Germany) utilized as the abutment. The zirconia crowns (Cercon Xt, Dentsply Sirona, Bensheim, Germany) were sintered and characterized and then cemented. The patient was satisfied with the esthetic outcome of the treatment.
Collapse
|
13
|
Wang B, Huang M, Dang P, Xie J, Zhang X, Yan X. PEEK in Fixed Dental Prostheses: Application and Adhesion Improvement. Polymers (Basel) 2022; 14:polym14122323. [PMID: 35745900 PMCID: PMC9228596 DOI: 10.3390/polym14122323] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/06/2022] [Accepted: 06/07/2022] [Indexed: 01/27/2023] Open
Abstract
Polyetheretherketone (PEEK) has been widely applied in fixed dental prostheses, comprising crowns, fixed partial dentures, and post-and-core. PEEK’s excellent mechanical properties facilitate better stress distribution than conventional materials, protecting the abutment teeth. However, the stiffness of PEEK is not sufficient, which can be improved via fiber reinforcement. PEEK is biocompatible. It is nonmutagenic, noncytotoxic, and nonallergenic. However, the chemical stability of PEEK is a double-edged sword. On the one hand, PEEK is nondegradable and intraoral corrosion is minimized. On the other hand, the inert surface makes adhesive bonding difficult. Numerous strategies for improving the adhesive properties of PEEK have been explored, including acid etching, plasma treatment, airborne particle abrasion, laser treatment, and adhesive systems.
Collapse
Affiliation(s)
- Biyao Wang
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Minghao Huang
- Liaoning Provincial Key Laboratory of Oral Diseases, Center of Implant Dentistry, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China;
| | - Pengrui Dang
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Jiahui Xie
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Xinwen Zhang
- Liaoning Provincial Key Laboratory of Oral Diseases, Center of Implant Dentistry, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China;
- Correspondence: (X.Z.); (X.Y.); Tel.: +86-024-31927731 (X.Z.); +86-024-31927715 (X.Y.)
| | - Xu Yan
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
- Correspondence: (X.Z.); (X.Y.); Tel.: +86-024-31927731 (X.Z.); +86-024-31927715 (X.Y.)
| |
Collapse
|
14
|
ZHOU SHANYU, YOU YUEHUA, HU CHEN, SUN TING, SHAO LONGQUAN. FRACTOGRAPHIC ANALYSIS OF LITHIUM DISILICATE CERAMICS AND MONOLITHIC ZIRCONIA CERAMICS. J MECH MED BIOL 2022. [DOI: 10.1142/s0219519422400127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Objective: To compare the fracture mode of lithium disilicate ceramics and zirconia ceramics through a single-load-to-failure test, and reveal the cause of failure through the fractographic analysis of fracture morphology. Methods: Based on the standardized preparations, 10 IPS e.max disilicate ceramic crowns (IPCs) and 10 monolithic zirconia ceramic crowns (MZCs) were designed and fabricated. All the specimens were placed on a universal material testing machine for a single-load-to-failure test. The fracture load was recorded, and two independent sample [Formula: see text]-tests were performed. Additionally, the type of fracture under a stereo-microscope was observed, and the morphological characteristics of the fracture with a scanning electron microscope (SEM) were investigated. Results: The fracture load of the IPC group was [Formula: see text][Formula: see text]N, and that of the MZC group was [Formula: see text][Formula: see text]N, with a statistically significant difference ([Formula: see text], [Formula: see text]). The fracture types of the IPC group and the MZC group were similar, namely, types II and III. The fracture modes of the two groups were all ceramic layer fracture. Through SEM, the origin of the crack on the occlusal surface could be traced back. The crystal fracture of IPC group had a rock sugar-like pattern, and the crystal distribution of MZC group was uniform. Conclusions: Zirconia ceramics have higher fracture load and a denser crystal structure compared to lithium disilicate. Fractographic analysis method could be a better way to analyze the failure mode of single-layer porcelain materials and reveal the origin of fracture.
Collapse
Affiliation(s)
- SHANYU ZHOU
- Department of Stomatology, Affiliated Longhua People’s Hospital, Southern Medical University, Shenzhen, Guangdong 518109, P. R. China
| | - YUEHUA YOU
- Department of Stomatology, Affiliated Longhua People’s Hospital, Southern Medical University, Shenzhen, Guangdong 518109, P. R. China
| | - CHEN HU
- Department of Stomatology, Nanfang Hospital, Southern Medical University Guangzhou, Guangdong 510515, P. R. China
| | - TING SUN
- The Affiliated Stomatology Hospital, Foshan University, Foshan, Guangdong 528000, P. R. China
| | - LONGQUAN SHAO
- Department of Stomatology, Nanfang Hospital, Southern Medical University Guangzhou, Guangdong 510515, P. R. China
| |
Collapse
|
15
|
Fischer P, Barbu HM, Fischer CAI, Pantea M, Baciu F, Vranceanu DM, Cotrut CM, Spinu TC. Bending Fracture of Different Zirconia-Based Bioceramics for Dental Applications: A Comparative Study. Materials (Basel) 2021; 14:ma14226887. [PMID: 34832293 PMCID: PMC8621405 DOI: 10.3390/ma14226887] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/08/2021] [Accepted: 11/10/2021] [Indexed: 01/09/2023]
Abstract
The fabrication of fixed dental prostheses using aesthetic materials has become routine in today’s dentistry. In the present study, three-unit full zirconia fixed prosthetic restorations obtained by computer-aided design/computer-aided manufacturing (CAD/CAM) technology were tested by bending trials. The prostheses were intended to replace the first mandibular left molar and were manufactured from four different types of zirconia bioceramics (KatanaTM Zirconia HTML and KatanaTM Zirconia STML/Kuraray Noritake Dental Inc.; NOVAZir® Fusion float® ml/NOVADENT/Dentaltechnik; and 3D PRO Zirconia/Bloomden Bioceramics). In total, sixteen samples were manufactured—four samples per zirconia material. Additionally, the morphology, grain size area distribution, and elemental composition were analyzed in parallelepiped samples made from the selected types of zirconia in three different areas, noted as the upper, middle, and lower areas. The scanning electron microscope (SEM) analysis highlighted that the grain size area varies with respect to the researched area and the type of material. Defects such as microcracks and pores were also noted to a smaller extent. In terms of grain size area, it was observed that most of the particles in all samples were under 0.5 μm2, while the chemical composition of the investigated materials did not vary significantly. The results obtained after performing the bending tests showed that a zirconia material with fewer structural defects and an increased percentage of grain size area under 0.5 µm2, ranging from ~44% in the upper area to ~74% in the lower area, exhibited enhanced mechanical behavior. Overall, the resulting values of all investigated parameters confirm that the tested materials are suitable for clinical use.
Collapse
Affiliation(s)
- Peter Fischer
- Oral Implantology Department, Titu Maiorescu University, 67A Gh. Petrascu Street, 040441 Bucharest, Romania; (P.F.); (H.M.B.)
| | - Horia Mihail Barbu
- Oral Implantology Department, Titu Maiorescu University, 67A Gh. Petrascu Street, 040441 Bucharest, Romania; (P.F.); (H.M.B.)
| | - Caroline Adela Ingrid Fischer
- Doctoral School, Faculty of Dental Medicine, Titu Maiorescu University, 67A Gh. Petrascu Street, 040441 Bucharest, Romania;
| | - Mihaela Pantea
- Department of Fixed Prosthodontics and Occlusology, Faculty of Dental Medicine, Carol Davila University of Medicine and Pharmacy, 17-23 Plevnei Street, 010221 Bucharest, Romania; (M.P.); (T.C.S.)
| | - Florin Baciu
- Department of Strength of Materials, Faculty of Industrial Engineering and Robotics, University Politehnica of Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania;
| | - Diana Maria Vranceanu
- Department of Metallic Materials Science, Physical Metallurgy, Faculty of Materials Science and Engineering, University Politehnica of Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania
- Correspondence: (D.M.V.); (C.M.C.); Tel.: +40-(0)21-316-9563 (D.M.V. & C.M.C.)
| | - Cosmin Mihai Cotrut
- Department of Metallic Materials Science, Physical Metallurgy, Faculty of Materials Science and Engineering, University Politehnica of Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania
- Correspondence: (D.M.V.); (C.M.C.); Tel.: +40-(0)21-316-9563 (D.M.V. & C.M.C.)
| | - Tudor Claudiu Spinu
- Department of Fixed Prosthodontics and Occlusology, Faculty of Dental Medicine, Carol Davila University of Medicine and Pharmacy, 17-23 Plevnei Street, 010221 Bucharest, Romania; (M.P.); (T.C.S.)
| |
Collapse
|
16
|
Abhay SS, Ganapathy D, Veeraiyan DN, Ariga P, Heboyan A, Amornvit P, Rokaya D, Srimaneepong V. Wear Resistance, Color Stability and Displacement Resistance of Milled PEEK Crowns Compared to Zirconia Crowns under Stimulated Chewing and High-Performance Aging. Polymers (Basel) 2021; 13:polym13213761. [PMID: 34771318 PMCID: PMC8587121 DOI: 10.3390/polym13213761] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 10/27/2021] [Accepted: 10/28/2021] [Indexed: 12/19/2022] Open
Abstract
Recently, polyetheretherketone (PEEK) has been introduced to the dental market as a high-performance and chemically inert biomaterial. This study aimed to compare the wear resistance, abrasiveness, color stability, and displacement resistance of zirconia and PEEK milled crowns. An ideal tooth preparation of a first maxillary molar was done and scanned by an intraoral scanner to make a digital model. Then, the prosthetic crown was digitally designed on the CAD software, and the STL file was milled in zirconia (CaroZiir S, Carol Zircolite Pvt. Ltd., Gujarat, India) and PEEK (BioHpp, Bredent GmbH, Senden, Germany) crowns using five-axis CNC milling machines. The wear resistance, color stability, and displacement resistance of the milled monolithic zirconia with unfilled PEEK crowns using a chewing simulator with thermocyclic aging (120,000 cycles) were compared. The antagonist wear, material wear, color stability, and displacement were evaluated and compared among the groups using the Wilcoxon-Mann-Whitney U-test. Zirconia was shown to be three times more abrasive than PEEK (p value < 0.05). Zirconia had twice the wear resistance of PEEK (p value < 0.05). Zirconia was more color stable than PEEK (p value < 0.05). PEEK had more displacement resistance than zirconia (p value < 0.05). PEEK offers minimal abrasion, better stress modulation through plastic deformation, and good color stability, which make it a promising alternative to zirconia crown.
Collapse
Affiliation(s)
- Simone Shah Abhay
- Department of Prosthodontics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, India; (S.S.A.); (D.G.); (D.N.V.); (P.A.); (A.H.)
| | - Dhanraj Ganapathy
- Department of Prosthodontics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, India; (S.S.A.); (D.G.); (D.N.V.); (P.A.); (A.H.)
| | - Deepak Nallaswamy Veeraiyan
- Department of Prosthodontics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, India; (S.S.A.); (D.G.); (D.N.V.); (P.A.); (A.H.)
| | - Padma Ariga
- Department of Prosthodontics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, India; (S.S.A.); (D.G.); (D.N.V.); (P.A.); (A.H.)
| | - Artak Heboyan
- Department of Prosthodontics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, India; (S.S.A.); (D.G.); (D.N.V.); (P.A.); (A.H.)
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Str. Koryun 2, Yerevan 0025, Armenia
| | - Pokpong Amornvit
- Golden Jubilee Medical Centre, Mahidol University, Nakon Pathom, Salaya 73170, Thailand;
| | - Dinesh Rokaya
- Department of Clinical Dentistry, International College of Dentistry, Walailak University, Bangkok 10400, Thailand
- Correspondence: (D.R.); (V.S.); Tel.: +66-2218-8535 (V.S.)
| | - Viritpon Srimaneepong
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand
- Correspondence: (D.R.); (V.S.); Tel.: +66-2218-8535 (V.S.)
| |
Collapse
|