1
|
Karasan D, Pitta J, Zarauz C, Strasding M, Liu X, Fehmer V, Sailer I. The influence of titanium-base abutment geometry and height on mechanical stability of implant-supported single crowns. Clin Oral Implants Res 2023. [PMID: 37929698 DOI: 10.1111/clr.14207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 10/22/2023] [Accepted: 11/01/2023] [Indexed: 11/07/2023]
Abstract
AIM This study aimed to investigate the influence of titanium base (ti-base) abutment macro- and micro-geometry on the mechanical stability of polymer-infiltrated ceramic network (PICN) screw-retained implant-supported single crowns (iSCs). MATERIALS AND METHODS Twelve specimens per group were used, comprising six different implant/ti-base abutment combinations restored with PICN iSCs: Nb-T (gingival height [GH]: 1.5 mm, prosthetic height [PH]: 4.3 mm), CC (GH: 0.8 mm, PH: 4.3 mm), CC-P (GH: 0.8 mm, PH: 7 mm), Nb-V (GH: 1.5 mm, PH: 6 mm), St (GH: 1.5 mm, PH: 5.5 mm), and Th (GH: 0.5 mm, PH: 9 mm). The specimens underwent thermo-mechanical aging, and those that survived were subsequently subjected to static loading until failure. The data were analyzed using a one-way ANOVA test followed by Tukey post hoc test (α = .05). RESULTS All specimens survived thermo-mechanical aging without complications, namely, visible cracks, debonding, or screw loosening. Th group demonstrated the highest strength values among all the groups, with significant differences compared to Nb-T (p < .05), CC (p < .001), and St (p < .001). Additionally, CC-P group exhibited significantly superior fracture strength results compared to CC (p < .05) and St (p < .05). CONCLUSION The choice of ti-base, particularly prosthetic height, had a significant influence on fracture resistance of PICN iSCs. Nevertheless, the height or geometrical features of the ti-base did not exhibit a significant influence on the mechanical behavior of the iSC/ti-base assembly under thermomechanical loading, as all specimens withstood the aging without complication or failure.
Collapse
Affiliation(s)
- Duygu Karasan
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - João Pitta
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Cristina Zarauz
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Malin Strasding
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Xinran Liu
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
- Department of Comprehensive Dentistry, Peking University and Hospital of Stomatology First Clinical Division, Beijing, China
| | - Vincent Fehmer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
2
|
Meier D, Astasov-Frauenhoffer M, Waltimo T, Zaugg LK, Rohr N, Zitzmann NU. Biofilm formation on metal alloys and coatings, zirconia, and hydroxyapatite as implant materials in vivo. Clin Oral Implants Res 2023; 34:1118-1126. [PMID: 37489537 DOI: 10.1111/clr.14146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 05/28/2023] [Accepted: 07/11/2023] [Indexed: 07/26/2023]
Abstract
OBJECTIVES Composition of implant material and its surface structure is decisive for oral biofilm accumulation. This study investigated biofilm formation on eight different materials. MATERIALS AND METHODS Eighteen healthy subjects wore intraoral splints fitted with two sets of eight materials for 24 h: zirconia [ZrO2 ]; silver-gold-palladium [AgAuPd]; titanium zirconium [TiZr]; Pagalinor [PA]; hydroxyapatite [HA]; silver-platinum [AgPt]; titanium aluminum niobium [TAN]; titanium grade4 [TiGr4]. Total biomass was stained by safranin to assess plaque accumulation while conventional culturing (CFU) was conducted to investigate viable parts of the biofilm. Cell viability of human gingival fibroblasts (HGF-1) was assessed in vitro. Statistical evaluation was performed with linear mixed-effects models to compare materials (geometric mean ratios, 95% CI), with the level of significance set at ɑ = .05. RESULTS Less biofilm mass and CFU were found on noble metal alloys (AgPt, AgAuPd, and PA). Compared to AgPt, PA had 2.7-times higher biofilm mass value, AgAuPd was 3.9-times, TiGr4 was 4.1-times, TiZr was 5.9-times, TAN was 7.7-times, HA was 7.8-times, and ZrO2 was 9.1-times higher (each p < .001). Similarly, CFU data were significantly lower on AgPt, AgAuPd had 4.1-times higher CFU values, PA was 8.9-times, TiGr4 was 11.2-times, HA was 12.5-times, TiZr was 13.3-times, TAN was 16.9-times, and ZrO2 was 18.5-times higher (each p < .001). HGF-1 viability varied between 47 ± 24.5% (HA) and 94.4 ± 24.6% (PA). CONCLUSION Noble alloys are considered as beneficial materials for the transmucosal part of oral implants, as less biofilm mass, lower bacterial counts, and greater cell viability were detected than on titanium- or zirconia-based materials.
Collapse
Affiliation(s)
- Donat Meier
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel (UZB), University of Basel, Basel, Switzerland
| | - Monika Astasov-Frauenhoffer
- Department Research, University Center for Dental Medicine Basel (UZB), University of Basel, Basel, Switzerland
| | - Tuomas Waltimo
- Department of Oral Health & Medicine, University Center for Dental Medicine Basel (UZB), University of Basel, Basel, Switzerland
| | - Lucia K Zaugg
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel (UZB), University of Basel, Basel, Switzerland
| | - Nadja Rohr
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel (UZB), University of Basel, Basel, Switzerland
- Department Research, University Center for Dental Medicine Basel (UZB), University of Basel, Basel, Switzerland
| | - Nicola U Zitzmann
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel (UZB), University of Basel, Basel, Switzerland
| |
Collapse
|
3
|
Humm VL, Sailer I, Thoma DS, Hämmerle CHF, Jung RE, Zembic A. 13-year follow-up of a randomized controlled study on zirconia and titanium abutments. Clin Oral Implants Res 2023; 34:911-919. [PMID: 37340530 DOI: 10.1111/clr.14117] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 05/22/2023] [Accepted: 06/04/2023] [Indexed: 06/22/2023]
Abstract
OBJECTIVES To assess survival rates and compare technical, biological, and esthetic outcomes of customized zirconia and titanium abutments at 13 years post loading. MATERIALS AND METHODS Initially, 22 patients with 40 implants in posterior regions were included. The sites were randomly assigned to 20 customized zirconia abutments with cemented all ceramic crowns (ACC) and 20 customized titanium abutments with cemented metal ceramic crowns (MCC). At a mean follow-up of 13.4 years, patients were examined and implants/restorations assessed for survival and technical complications, as well as biological and esthetic outcomes (pocket probing depth [PPD], bleeding on probing [BOP], plaque control record [PCR], bone level [BL], papilla index [PAP], mucosal thickness, and recession (distance of the margo mucosae [MM]/margo gingivae MG)). Descriptive analyses were performed for all outcome measures. RESULTS Fifteen patients with 21 abutments (13 zirconia, 8 titanium) were examined at 13 years. The drop-out rate was 25% (patient level). The technical survival rate of the abutments was 100%. The survival rate on the restorative level (crowns) was 100%. The assessed biological outcomes (PPD, PCR, BOP, BL) and esthetic outcomes (MG, PAP) were similar. CONCLUSIONS Zirconia and titanium abutments supporting single implant-borne restorations rendered a high survival rate and minimal differences in terms of technical, biological, and esthetic outcomes at 13 years of follow-up.
Collapse
Affiliation(s)
- Viviane Laura Humm
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zürich, Zürich, Switzerland
- Private practice, Winterthur, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Occlusion, University clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Daniel Stefan Thoma
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zürich, Zürich, Switzerland
| | | | - Ronald Ernst Jung
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zürich, Zürich, Switzerland
| | | |
Collapse
|
4
|
El-Mahdy M, Aboelfadl A, Ahmed F, El-Banna A, Wahsh M. Strain gauge analysis and fracture resistance of implant-supported PEKK hybrid abutments restored with two crown materials: An in vitro study. Dent Med Probl 2023; 60:497-503. [PMID: 37815514 DOI: 10.17219/dmp/170311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 07/30/2023] [Accepted: 08/03/2023] [Indexed: 10/11/2023] Open
Abstract
BACKGROUND Polyetherketoneketone (PEKK) was recently introduced as an alternative to titanium and ceramic implant abutments due to its apparent ability to dissipate excessive strain around dental implants. However, the biomechanical behaviors of implant abutment crown systems may change depending on the crown and abutment material combinations used. OBJECTIVES This study aimed to assess how the crown material affects strain generation and fracture resistance of PEKK hybrid abutment crowns. MATERIAL AND METHODS Sixteen dummy implants (Ø 3.7 x 11 mm), simulating maxillary first premolars, were restored with 16 milled PEKK hybrid abutments and randomly categorized into two groups according to the crown material (n = 8): Group C, milled composite crowns cemented on PEKK hybrid abutments; and Group Z, ultra-translucent zirconia crowns cemented on PEKK hybrid abutments. Before thermocycling, a cyanoacrylate-base adhesive was used to position two strain gauges on buccal and lingual crestal bone surfaces, and a vertical load (100 N) was applied to the central fossa to record the strain generated. Then, all samples were thermocycled between 5°C and 55°C before being loaded to fracture on a universal testing machine. Modes of failure were observed under an optical microscope, and representative samples were examined using a scanning electron microscope. Independent t-tests were used for intergroup comparisons. The significance level was set at (p < 0.05) for all tests.. RESULTS The results showed a significant difference between both groups. The zirconia group recorded significantly higher strain and fracture resistance values than the composite group (p < 0.001). There was a positive correlation between the strain developed in peri-implant crestal bone and fracture resistance of the abutment crown complex. CONCLUSIONS Strains developed in both groups were within the acceptable clinical range. The crown material substantially impacted the strain and fracture of the PEKK hybrid abutment crown system.
Collapse
Affiliation(s)
- Manar El-Mahdy
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Ahmad Aboelfadl
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Fatma Ahmed
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Ahmed El-Banna
- Department of Biomaterials, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Marwa Wahsh
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
- Department of Fixed Prosthodontics, Faculty of Dentistry, Galala University, Suez, Egypt
| |
Collapse
|
5
|
Ramidan JC, de Mendonça E Bertolini M, Júnior MRM, Portela MB, Lourenço EJV, de Moraes Telles D. Filling Materials Efficacy on Preventing Biofilm Formation Inside Screw Access Channels of Implant Abutments. J ORAL IMPLANTOL 2022; 48:573-577. [PMID: 35503968 DOI: 10.1563/aaid-joi-d-20-00191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 03/13/2022] [Accepted: 03/25/2022] [Indexed: 11/22/2022]
Abstract
The choice of the material used to fill screw access channels in implant-supported prostheses depends, in most cases, on operator's preference, without considering the susceptibility of biofilm colonization. Therefore, the aim of this study was to determine and compare the total amount of biofilm formed on different materials used to fill screw access channels in implant abutments. For this propose, titanium implant analogs were attached on abutments and divided into 5 groups: positive control (no filling material); negative control (closed with resin); and filled with cotton, gutta-percha, or polytetrafluoroethylene (PTFE). The analogs with attached abutments were then immersed in a brain heart infusion medium containing Candida albicans (strain 10231 from American Type Culture Collection [ATCC]) and incubated aerobically at 37°C with gentle agitation. After 15 days, materials were removed, and total viable biofilm on each material was quantified by methyl tetrazolium reduction assay at 490 nm. All experiments were performed in triplicate. Data were processed by IBM SPSS Statistic software using 1-way analysis of variance and Bonferroni post hoc tests to analyze differences between groups, with an overall significance level of P < .001. A significant difference was observed between cotton and gutta-percha (P < .017) and between cotton and PTFE (P < .025). However, there was no statistical difference between gutta-percha and PTFE (P > .050). Thus, this in vitro experiment showed that gutta-percha and PTFE presented lower biofilm formation compared with cotton when used to fill screw access channels. These results can provide a basis for future clinical studies that can be a guide to decreasing the occurrence of gaps and bacterial growth inside the implant/abutment attachment site. In addition, controlled in vivo studies are necessary to confirm the clinical viability of findings of this study.
Collapse
Affiliation(s)
- Juliana Cabral Ramidan
- Department of Prosthodontics, School of Dentistry, Rio de Janeiro State University, Rio de Janeiro, Brazil
| | - Martinna de Mendonça E Bertolini
- Department of Oral Health and Diagnostic Sciences, Division of Periodontology, University of Connecticut Health Center, Farmington, Connecticut, USA
| | | | - Maristela Barbosa Portela
- Department of Clinics and Pediatric Dentistry, School of Dentistry, Fluminense Federal University, Niteroi, Rio de Janeiro, Brazil
| | | | - Daniel de Moraes Telles
- Department of Prosthodontics, School of Dentistry, Rio de Janeiro State University, Rio de Janeiro, Brazil
| |
Collapse
|
6
|
Kraus RD, Espuelas C, Hämmerle CHF, Jung RE, Sailer I, Thoma DS. Five-year randomized controlled clinical study comparing cemented and screw-retained zirconia-based implant-supported single crowns. Clin Oral Implants Res 2022; 33:537-547. [PMID: 35224774 PMCID: PMC9313572 DOI: 10.1111/clr.13913] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 01/17/2022] [Accepted: 02/09/2022] [Indexed: 11/29/2022]
Abstract
Objectives To compare screw‐retained and cemented all‐ceramic implant‐supported single crowns regarding biological and technical outcomes over a 5‐year observation period. Materials and methods In 44 patients, 44 two‐piece dental implants were placed in single‐tooth gaps in the esthetic zone. Patients randomly received a screw‐retained (SR) or cemented (CR) all‐ceramic single crown and were then re‐examined annually up to 5 years. Outcome measures included: clinical, biological, technical, and radiographic parameters. Data were statistically analyzed with Wilcoxon–Mann–Whitney, Wilcoxon, and Fisher's exact tests. Results During the observation period, three patients (6.8%) were loss to follow‐up. Eight restorations (18.2%, CI (8.2%, 32.7%)) were lost due to technical (6 patients, 13.6% (CI (5.2%, 27.4%)), 2 CR and 4 SR group, intergroup p = .673; implants still present) or biological complications (2 patients, 4.5% (CI (0.6%, 16.5%)), only CR group, intergroup p = .201, both implants lost). This resulted in a survival rate of 81.2% (CI (65.9%, 90.1%)) on the restorative level (18 SR; 15 CR, 3 lost to follow‐up). At the 5‐year follow‐up, the median marginal bone levels were located slightly apical relative to the implant shoulder with 0.4 mm (0.5; 0.3) (SR) and 0.4 mm (0.8; 0.3) (CR) (intergroup p = .582). Cemented restorations demonstrated a significantly higher biological complication rate (36.8%, SR: 0.0%; intergroup p = .0022), as well as a significantly higher overall complication rate (68.4%, SR: 22.7%, intergroup p = .0049). All other outcomes did not differ significantly between the two groups (p > .05). Conclusions All‐ceramic single‐tooth restorations on two‐piece dental implants resulted in a relatively low survival rate. Cemented restorations were associated with a higher biological and overall complication rate than screw‐retained restorations.
Collapse
Affiliation(s)
- Riccardo D Kraus
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Catharina Espuelas
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Christoph H F Hämmerle
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Ronald E Jung
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Daniel S Thoma
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
7
|
Dini C, Borges GA, Costa RC, Magno MB, Maia LC, Barão VAR. Peri-implant and esthetic outcomes of cemented and screw-retained crowns using zirconia abutments in single implant-supported restorations-A systematic review and meta-analysis. Clin Oral Implants Res 2021; 32:1143-1158. [PMID: 34352144 DOI: 10.1111/clr.13824] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 06/23/2021] [Accepted: 07/07/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To evaluate the peri-implant tissue changes and esthetic outcomes of cemented and screw-retained crowns of single-tooth implants in the esthetic zone using zirconia abutments. MATERIAL AND METHODS An electronic search was performed on nine databases. The risk-of-bias was assessed by the revised Cochrane risk-of-bias tool for randomized (RoB 2) and non-randomized (ROBINS-I) clinical trials. Marginal bone level change, soft tissue thickness, bleeding on probing, probing depth, survival rates of implants and crowns, complications, plaque and papilla indexes, and pink esthetic score data were extracted and analyzed. The certainty of evidence was accessed through the GRADE approach. RESULTS Nine records were included and 7 were used in the meta-analyses. Screw-retained crowns presented greater marginal bone level change (MD -0.04 [-0.08, -0.00] p = 0.04, I2 = 0%) compared to cemented crowns up to 1-year. At 3 and 4 years no significant differences (p > 0.05) were observed. Soft tissue thickness did not differ between groups (p > 0.05). The bleeding on probing was higher in cemented group than in screw-retained crowns at 1-year (MD 0.17 [0.08, 0.27] p = 0.0005, I2 = 0%), at medium-term periods (3 and 4 years) no statistically significant differences (p > 0.05) were observed for this outcome. Probing depth, survival rates of implants and crowns, complications, and plaque index, as well as esthetic analysis using the papilla index and pink esthetic score did not differ statistically (p > 0.05) between both retention systems at short and medium-term periods. CONCLUSION The connection system considering zirconia abutments presented no influence on peri-implant parameters and esthetics evaluation for medium-term periods (3 and 4 years).
Collapse
Affiliation(s)
- Caroline Dini
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP, Piracicaba, Brazil
| | - Guilherme Almeida Borges
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP, Piracicaba, Brazil
| | - Raphael Cavalcante Costa
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP, Piracicaba, Brazil
| | - Marcela Baraúna Magno
- Department of Pediatric Dentistry and Orthodontics, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Rua Rodolpho Paulo Rocco - Cidade Universitária, Rio de Janeiro, Brazil
| | - Lucianne Cople Maia
- Department of Pediatric Dentistry and Orthodontics, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Rua Rodolpho Paulo Rocco - Cidade Universitária, Rio de Janeiro, Brazil
| | - Valentim Adelino Ricardo Barão
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP, Piracicaba, Brazil
| |
Collapse
|
8
|
Handa M, Marya P, Gupta V, Chopra S. Comparative evaluation of microleakage of metallic copings luted with three different commercially available luting cements: An in vitro study. J Indian Prosthodont Soc 2021; 21:57-65. [PMID: 33835069 PMCID: PMC8061442 DOI: 10.4103/jips.jips_19_20] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Aim To evaluate the microleakage of metallic copings luted with three different commercially available luting cements. Setting and Design Comparative evaluation in vitro study. Materials and Methods Thirty replicas of abutment analog were milled and divided into 3 groups. Nickel chromium copings were fabricated; marginal gap was evaluated with optical microscope and luted with Zinc Oxide Non Eugenol cement, Zinc Polycarboxylate cement and Zinc Phosphate cement. After Thermocycling, cemented specimens were placed into 0.5% aqueous solution of basic fuchsin solution for 24 hours for dye penetration. Copings were longitudinally sectioned and microleakage scores were evaluated. Statistical Analysis Used Kruskal-Wallis analysis of variance (ANOVA) followed by Chi-Square test. Pairwise comparison of groups with Mann Whitney U test. Result Mean microleakage score was least for Zinc Phosphate cement (1.075 ± 0.85) followed by Zinc Polycarboxylate cement (1.80± 0.23) and most for Zinc Oxide Non Eugenol (2.1± 0.37). The results of the study were statistically significant, P < 0.05. Conclusions Within the limitations of the study, it was found that all cements exhibited certain amount of microleakage. Zinc Phosphate cement exhibited a mean microleakage score that was significantly lower than Zinc Oxide Non Eugenol cement and Zinc Polycarboxylate cement. When microleakage scores of Zinc Oxide Non Eugenol cement and Zinc Polycarboxylate cement were compared, the difference was found to be insignificant indicating that microleakage in these cements is similar.
Collapse
Affiliation(s)
- Mohit Handa
- Department of Prosthodontics, Genesis Institute of Dental Sciences and Research, Ferozepur, Punjab, India
| | - Pratibha Marya
- Department of Conservative Dentistry and Endodontics, Genesis Institute of Dental Sciences and Research, Ferozepur, Punjab, India
| | - Varun Gupta
- Private Practitioner, Prosthodontist, Kharar, Punjab, India
| | - Sumit Chopra
- Department of Prosthodontics, Genesis Institute of Dental Sciences and Research, Ferozepur, Punjab, India
| |
Collapse
|
9
|
Strauss FJ, Hämmerle CHF, Thoma DS. Short communication: Cemented implant reconstructions are associated with less marginal bone loss than screw-retained reconstructions at 3 and 5 years of loading. Clin Oral Implants Res 2021; 32:651-656. [PMID: 33686723 DOI: 10.1111/clr.13737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Revised: 01/28/2021] [Accepted: 03/03/2021] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To analyse whether there is a difference in marginal bone levels (MBL) and the respective changes between cemented and screw-retained reconstructions at 3 and 5 years of loading. METHODS Radiographic data from 14 prospective multicentre clinical trials following implant loading with fixed cemented (CEM) or screw-retained (SCREW) reconstructions with a 3- to 5-year follow-up were retrieved from a database. MBL and MBL changes were assessed at initiation of implant loading (BL), at 3 (FU-3) and 5 years (FU-5) thereafter. The presence of peri-implantitis was also determined. RESULTS Data from 1,672 implants at BL, 1,565 implants at FU-3 and 1,109 implants at FU-5 were available. The mean MBL amounted to 0.57 mm (SD 0.87) at BL, 0.55 mm (SD 0.86) at FU-3 and 0.65 mm (SD 1.18) at FU-5. At FU-3, the mean MBL was 0.44 mm (SD 0.65) in group CEM and 0.63 mm (SD 0.99) in group SCREW showing a significant difference between the groups (intergroup <0.05). At FU-5, the mean MBL was 0.42 mm (SD 0.77) in CEM and 0.80 mm (SD 1.37) in SCREW, again with significant differences between both groups (p < .05). MBL changes between BL and FU-3 amounted to 0.11 mm (SD 1.02) (bone loss) in SCREW and -0.17 mm (SD 1.03) (bone gain) in CEM. Similarly, mean MBL changes from BL to FU-5 amounted to 0.23 mm (SD 1.31) (bone loss) in SCREW and -0.26 mm (SD 1.27) (bone gain) in CEM. The prevalence of peri-implantitis amounted to 6.9% in CEM and 5.6% in group SCREW (intergroup p = .29063) at FU-3. At FU-5, peri-implantitis amounted to 4.6% in CEM and 6.2% in group SCREW (intergroup p = .28242). CONCLUSION Cemented implant reconstructions compared with screw-retained reconstructions revealed higher marginal bone levels and similar rates of peri-implantitis during 5 years. The difference in MBL and the respective changes between the two groups, however, appear to be clinically negligible.
Collapse
Affiliation(s)
- Franz-Josef Strauss
- Clinic of Reconstructive Dentistry, University of Zurich, Zurich, Switzerland
| | | | - Daniel S Thoma
- Clinic of Reconstructive Dentistry, University of Zurich, Zurich, Switzerland
| |
Collapse
|
10
|
Maminskas J, Pilipavicius J, Staisiunas E, Baranovas G, Alksne M, Daugela P, Juodzbalys G. Novel Yttria-Stabilized Zirconium Oxide and Lithium Disilicate Coatings on Titanium Alloy Substrate for Implant Abutments and Biomedical Application. Materials (Basel) 2020; 13:E2070. [PMID: 32365921 PMCID: PMC7254192 DOI: 10.3390/ma13092070] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 04/20/2020] [Accepted: 04/28/2020] [Indexed: 12/30/2022]
Abstract
This study aimed to create novel bioceramic coatings on a titanium alloy and evaluate their surface properties in comparison with conventional prosthetic materials. The highly polished titanium alloy Ti6Al4V (Ti) was used as a substrate for yttria-stabilized zirconium oxide (3YSZ) and lithium disilicate (LS2) coatings. They were generated using sol-gel strategies. In comparison, highly polished surfaces of Ti, yttria-stabilized zirconium oxide (ZrO2), polyether ether ketone (PEEK) composite, and poly(methyl methacrylate) (PMMA) were utilized. Novel coatings were characterized by an X-ray diffractometer (XRD) and scanning electron microscope (SEM). The roughness by atomic force microscope (AFM), water contact angle (WCA), and surface free energy (SFE) were determined. Additionally, biocompatibility and human gingival fibroblast (HGF) adhesion processes (using a confocal laser scanning microscope (CLSM)) were observed. The deposition of 3YSZ and LS2 coatings changed the physicochemical properties of the Ti. Both coatings were biocompatible, while Ti-3YSZ demonstrated the most significant cell area of 2630 μm2 (p ≤ 0.05) and the significantly highest, 66.75 ± 4.91, focal adhesions (FAs) per cell after 24 h (p ≤ 0.05). By contrast, PEEK and PMMA demonstrated the highest roughness and WCA and the lowest results for cellular response. Thus, Ti-3YSZ and Ti-LS2 surfaces might be promising for biomedical applications.
Collapse
Affiliation(s)
- Julius Maminskas
- Department of Prosthodontics, Lithuanian University of Health Sciences, 50106 Kaunas, Lithuania
| | - Jurgis Pilipavicius
- Department of Chemical Engineering and Technology, Center for Physical Sciences and Technology (FTMC), 02300 Vilnius, Lithuania;
- Faculty of Chemistry and Geosciences, Vilnius University, 10257 Vilnius, Lithuania; (E.S.); (G.B.)
| | - Edvinas Staisiunas
- Faculty of Chemistry and Geosciences, Vilnius University, 10257 Vilnius, Lithuania; (E.S.); (G.B.)
| | - Gytis Baranovas
- Faculty of Chemistry and Geosciences, Vilnius University, 10257 Vilnius, Lithuania; (E.S.); (G.B.)
| | - Milda Alksne
- Institute of Biochemistry, Life Sciences Center, Vilnius University, 10257 Vilnius, Lithuania;
| | - Povilas Daugela
- Department of Maxillofacial Surgery, Lithuanian University of Health Sciences, 50140 Kaunas, Lithuania; (P.D.); (G.J.)
| | - Gintaras Juodzbalys
- Department of Maxillofacial Surgery, Lithuanian University of Health Sciences, 50140 Kaunas, Lithuania; (P.D.); (G.J.)
| |
Collapse
|
11
|
Guguloth H, Duggineni CR, Chitturi RK, Sujesh M, Ravvali T, Amiti RR. Correlation between abutment angulation and off-axial stresses on biomechanical behavior of titanium and zirconium implants in the anterior maxilla: A three-dimensional finite element analysis study. J Indian Prosthodont Soc 2019; 19:353-361. [PMID: 31649445 PMCID: PMC6803790 DOI: 10.4103/jips.jips_268_19] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2019] [Revised: 08/29/2019] [Accepted: 09/21/2019] [Indexed: 11/04/2022] Open
Abstract
Aim The aim of the present study was to evaluate the stress distribution around the titanium and zirconium implant with different abutment angulations in the anterior maxilla to off-axial load. Setting and Design In vitro - Comparative study. Materials and Methods Two models of titanium and zirconium implants (4 mm × 13 mm) and abutment with at 0°, 15°, 25° angulations were modeled to replace missing right central incisor using three-dimensional finite element analysis. A bite force of 178 N was applied on the lingual fossa of crowns at an angle of 120° off-axial to the long axis of implant. Statistical Analysis Used Nil. Results Von Misses stresses observed are as follows: (1) at the implant-bone interface Ti 0 (8.31 MPa), Zr 0 (8.57 MPa), Ti 15 (83.59 MPa), Zr 15 (98.07 MPa), Ti 25 (197.8 MPa), and Zr 25 (265.77 MPa); (2) at the implant-abutment interface Ti 0 (5.90 MPa), Zr 0 (6.45 MPa), Ti 15 (19.13 MPa), Zr 15 (19.32 MPa), Ti 25 (38.65 MPa), and Zr 25 (38.26 MPa); and (3) within superstructure Ti 0 (3.11 MPa), Zr 0 (5.02 MPa), Ti 15 (6.17 MPa), Zr 15 (5.02 MPa), Ti 25 (8.15 MPa), and Zr 25 (6.131 Mpa). Conclusion Stress behavior of titanium and zirconium implant with tested abutment angulation at implant-abutment interface and within the superstructure was similar, except at implant-bone interface.
Collapse
Affiliation(s)
- Harilal Guguloth
- Department of Prosthodontics, Mamata Dental College, Khammam, Telangana, India
| | | | - Ravi Kumar Chitturi
- Department of Prosthodontics, Mamata Dental College, Khammam, Telangana, India
| | - M Sujesh
- Department of Prosthodontics, Mamata Dental College, Khammam, Telangana, India
| | - T Ravvali
- Department of Prosthodontics, Mamata Dental College, Khammam, Telangana, India
| | - Roja Roshan Amiti
- Department of Prosthodontics, Mamata Dental College, Khammam, Telangana, India
| |
Collapse
|
12
|
Soo SY, Silikas N, Satterthwaite J. Measurement of Fracture Strength of Zirconia Dental Implant Abutments with Internal and External Connections Using Acoustic Emission. Materials (Basel) 2019; 12:E2009. [PMID: 31234580 DOI: 10.3390/ma12122009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 06/19/2019] [Accepted: 06/20/2019] [Indexed: 11/16/2022]
Abstract
A single paragraph of about 200 words maximum. For research articles, abstracts should give a pertinent overview of the work. We strongly encourage authors to use the following style of structured abstracts, but without headings: (1) Background: Place the question addressed in a broad context and highlight the purpose of the study; (2) Methods: Describe briefly the main methods or treatments applied; (3) Results: Summarize the article's main findings; and (4) Conclusions: Indicate the main conclusions or interpretations. The abstract should be an objective representation of the article, it must not contain results which are not presented and substantiated in the main text and should not exaggerate the main conclusions. Please add in this section. The aim of the study was to investigate the fracture behaviour of four different groups of zirconia abutments with internal and external connections: (A) Astra Tech ZirDesign™ abutment on Astra Tech Implants, (B) Procera® Esthetic abutment on Nobel Biocare MK III Groovy Implants, (C) IPS e.max® on Straumann Implants, and (D) ZiReal® Posts on Biomet 3I implants. The load was applied on the assemblies using a Zwick universal testing machine: the initial and final failure loads and amplitude were recorded using acoustic emission technique. Mean initial and final failure force was found to be significantly different in each group (P < 0.001). IPS e.max® Straumann abutments exhibited the highest resistance to final fracture force compared to other abutment types. Acoustic emission can be used as one of the methods to detect fracture behaviour of implant abutments. There were no significant differences in fracture loads between the internal and externally connected zirconia abutments studied. However, externally connected abutments demonstrated screw loosening and some deformations.
Collapse
|
13
|
Ramenzoni LL, Attin T, Schmidlin PR. In Vitro Effect of Modified Polyetheretherketone (PEEK) Implant Abutments on Human Gingival Epithelial Keratinocytes Migration and Proliferation. Materials (Basel) 2019; 12:E1401. [PMID: 31036797 DOI: 10.3390/ma12091401] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 04/26/2019] [Accepted: 04/27/2019] [Indexed: 12/29/2022]
Abstract
Improving soft tissue attachment to implant abutments is a crucial factor for enduring health and maintenance of soft peri-implant tissue health. In this in vitro study we aimed to compare the biocompatibility of three different abutment surfaces: titanium, zirconia and modified polyetheretherketone (PEEK). Surface topography, roughness and wettability were investigated with scanning electron microscopy, profilometer and contact angle meter, respectively. Human gingival epithelial keratinocytes were examined for viability, morphology, proliferation and migration by using tetrazolium salt colorimetric assay, scanning electron microscopy imaging, immunofluorescence bromodeoxyuridine analysis and scratch wound healing assays. Roughness measurements revealed differences between the investigated surfaces. Keratinocytes cultured on all examined surfaces indicated adhesion and attachment by means of scanning electron microscopy imaging. Cell viability assays showed no significant differences between the groups (p > 0.05). The modified PEEK surface similarly improved surface roughness in comparison to titanium and zirconia, which resulted in greater and equivalent cell proliferation and migration. The study methodology showed here may emphasize the importance of cell interactions with different abutment materials, which in part increases the changes of implant success. PEEK, titanium and zirconia surface types used in this study showed mostly similar epithelial biological responses.
Collapse
|
14
|
Pjetursson BE, Zarauz C, Strasding M, Sailer I, Zwahlen M, Zembic A. A systematic review of the influence of the implant-abutment connection on the clinical outcomes of ceramic and metal implant abutments supporting fixed implant reconstructions. Clin Oral Implants Res 2019; 29 Suppl 18:160-183. [PMID: 30306682 DOI: 10.1111/clr.13362] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/07/2018] [Indexed: 11/29/2022]
Abstract
OBJECTIVES The objective of this systematic review was to assess the influence of implant-abutment connection and abutment material on the outcome of implant-supported single crowns (SCs) and fixed dental prostheses (FDPs). METHODS An electronic Medline search complemented by manual searching was conducted to identify randomized controlled clinical trials, prospective and retrospective studies with a mean follow-up time of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Failure and complication rates were analyzed using robust Poisson regression, and comparisons were made with multivariable Poisson regression models. RESULTS The search provided 1511 titles and 177 abstracts. Full-text analysis was performed for 147 articles resulting in 60 studies meeting the inclusion criteria. Meta-analysis of these studies indicated an estimated 5-year survival rate of 97.6% for SCs and 97.0% for FDPs supported by implants with internal implant-abutment connection and 95.7% for SCs and 95.8% for FDPs supported by implants with external connection. The 5-year abutment failure rate ranged from 0.7% to 2.8% for different connections with no differences between the types of connections. The total number of complications was similar between the two connections, yet, at external connections, abutment or occlusal screw loosening was more predominant. Ceramic abutments, both internally and externally connected, demonstrated a significantly higher incidence of abutment fractures compared with metal abutments. CONCLUSION For implant-supported SCs, both metal and ceramic abutments with internal and external connections exhibited high survival rates. Moreover, implant-supported FDPs with metal abutments with internal and external connections for also showed high survival rates.
Collapse
Affiliation(s)
- Bjarni Elvar Pjetursson
- Department of Reconstructive Dentistry, Faculty of Odontology, University of Iceland, Reykjavik, Iceland.,Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Cristina Zarauz
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Malin Strasding
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Marcel Zwahlen
- Institute of Social and Preventive Medicine, University of Bern, Bern, Switzerland
| | - Anja Zembic
- Clinic of Fixed and Removable Prosthodontics and Material Science, University of Zurich, Zurich, Switzerland
| |
Collapse
|
15
|
Abstract
INTRODUCTION The use of zirconia in medicine and dentistry has rapidly expanded over the past decade, driven by its advantageous physical, biological, esthetic, and corrosion properties. Zirconia orthopedic hip replacements have shown superior wear-resistance over other systems; however, risk of catastrophic fracture remains a concern. In dentistry, zirconia has been widely adopted for endosseous implants, implant abutments, and all-ceramic crowns. Because of an increasing demand for esthetically pleasing dental restorations, zirconia-based ceramic restorations have become one of the dominant restorative choices. Areas covered: This review provides an updated overview of the applications of zirconia in medicine and dentistry with a focus on dental applications. The MEDLINE electronic database (via PubMed) was searched, and relevant original and review articles from 2010 to 2016 were included. Expert commentary: Recent data suggest that zirconia performs favorably in both orthopedic and dental applications, but quality long-term clinical data remain scarce. Concerns about the effects of wear, crystalline degradation, crack propagation, and catastrophic fracture are still debated. The future of zirconia in biomedical applications will depend on the generation of these data to resolve concerns.
Collapse
Affiliation(s)
- Yen-Wei Chen
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - Joelle Moussi
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - Jeanie L Drury
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - John C Wataha
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| |
Collapse
|
16
|
Gutmacher Z, Levi G, Blumenfeld I, Machtei EE. Soft and Hard Tissue Changes around Tissue-Oriented Tulip-Design Implant Abutments: A 1-Year Randomized Prospective Clinical Trial. Clin Implant Dent Relat Res 2015; 17:891-7. [PMID: 26434929 DOI: 10.1111/cid.12209] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The advantages of platform switching using narrower abutments remain controversial. Many researchers suggest that platform switching can yield enhanced clinical results, while others remain skeptical. We hypothesize that the effectiveness of platform switching might be associated with the degree of reduction in size of the abutment. PURPOSE To radiographically and clinically examine a new abutment design created to move the implant-abutment interface farther medially. MATERIALS AND METHODS This was a prospective, randomized controlled clinical trial that included 27 patients (41 MIS Lance Plus® implants; MIS Implant Technologies, Karmiel, Israel). The patients' age ranged from 39 to 75 years. At the second stage of the surgery, the implants were randomly assigned to either the new platform switch Tulip abutment (TA) design or to the standard platform abutment (SA). Implant probing depth (IPD) and bleeding on probing (BOP) were recorded at baseline and after 12 months. Standardized periapical radiographs were taken (at baseline and at 12 months) and the marginal bone height measured. RESULTS All implants were successfully integrated. The mean IPD at 1 year post-op was 2.91 mm for the SA group and 2.69 mm for the TA group (p > .05). Similarly, the BOP at 1 year was almost identical in both groups. The mean values of bone resorption at baseline were 0.98 ± 0.37 mm and 0.69 ± 0.20 for the TA and SA groups, respectively (p > .05). Bone loss (baseline to 12 months) was significantly greater in the SA group compared with the TA group. CONCLUSIONS Use of the new TA, with its significantly downsized diameter, resulted in reduced bone loss at 1 year. Further research will be required to assess the long-term effect of this abutment on peri-implant health.
Collapse
Affiliation(s)
- Zvi Gutmacher
- Department of Maxillofacial Rehabilitation, School of Graduate Dentistry, Rambam Health Care Campus, Haifa, Israel
| | - Guy Levi
- Department of Periodontology, School of Graduate Dentistry, Rambam Health Care Campus, Haifa, Israel
| | - Israel Blumenfeld
- Department of Maxillofacial Rehabilitation, School of Graduate Dentistry, Rambam Health Care Campus, Haifa, Israel
| | - Eli E Machtei
- Department of Periodontology, School of Graduate Dentistry, Rambam Health Care Campus, Haifa, Israel.,Faculty of Medicine, Technion - Israeli Institute of Technology, Haifa, Israel
| |
Collapse
|
17
|
Zembic A, Philipp AOH, Hämmerle CHF, Wohlwend A, Sailer I. Eleven-Year Follow-Up of a Prospective Study of Zirconia Implant Abutments Supporting Single All-Ceramic Crowns in Anterior and Premolar Regions. Clin Implant Dent Relat Res 2014; 17 Suppl 2:e417-26. [PMID: 25180473 DOI: 10.1111/cid.12263] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Clinical studies on zirconia abutments report very good survival rates and biological and technical results, but few have an observation period of more than 5 years. PURPOSE The aim of this study was to assess the long-term performance of customized zirconia implant abutments supporting all-ceramic crowns. MATERIALS AND METHODS Twenty-seven patients receiving 54 single implants were included (25 incisors, 14 canines, 15 premolars in both jaws). Yttria-stabilized zirconia abutments were screwed to the implants with a defined torque. All-ceramic crowns were adhesively cemented onto the abutments. The implants, abutments, and crowns were clinically and radiographically examined after 11 years of use. Modified United States Public Health Service (USPHS) criteria were used to assess technical outcomes: fracture of abutment/crown framework/veneering ceramic, loosening of abutment screw/crown, marginal adaptation, anatomical form, occlusal wear, and abutment fit. The biological parameters were pocket probing depth, plaque control record, bleeding on probing, papilla index, and gingival/mucosal recession at implants and neighboring natural teeth. The cumulative success rate of abutments and crowns was calculated by the Kaplan-Meier method. The results of the USPHS criteria were analyzed descriptively. RESULTS Sixteen patients with 31 zirconia abutments were examined at 11.3 (±0.9) years after implantation. No abutment or crown was lost. The cumulative success rate was 96.3% for abutments and 90.7% for crowns. Two abutment screws loosened, and three crowns exhibited minor chipping. There were no biological complications. CONCLUSIONS Customized zirconia single implant abutments exhibited excellent long-term outcomes in anterior and premolar regions.
Collapse
Affiliation(s)
- Anja Zembic
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center for Dental Medicine, University of Zurich, Zurich, Switzerland.,Department of Oral Implantology and Prosthetic Dentistry, Academic Center for Dentistry Amsterdam, MOVE Research Institute, Amsterdam, The Netherlands
| | - Alexander Otto Hermann Philipp
- Effretikon, Switzerland.,Clinic for Preventive Dentistry, Periodontology and Cariology, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Christoph Hans Franz Hämmerle
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| | | | - Irena Sailer
- Clinic of Fixed Prosthodontics and Biomaterials, School of Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
18
|
Cosgarea R, Gasparik C, Dudea D, Culic B, Dannewitz B, Sculean A. Peri-implant soft tissue colour around titanium and zirconia abutments: a prospective randomized controlled clinical study. Clin Oral Implants Res 2014; 26:537-44. [PMID: 24961535 DOI: 10.1111/clr.12440] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/17/2014] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To objectively determine the difference in colour between the peri-implant soft tissue at titanium and zirconia abutments. MATERIALS AND METHODS Eleven patients, each with two contralaterally inserted osteointegrated dental implants, were included in this study. The implants were restored either with titanium abutments and porcelain-fused-to-metal crowns, or with zirconia abutments and ceramic crowns. Prior and after crown cementation, multi-spectral images of the peri-implant soft tissues and the gingiva of the neighbouring teeth were taken with a colorimeter. The colour parameters L*, a*, b*, c* and the colour differences ΔE were calculated. Descriptive statistics, including non-parametric tests and correlation coefficients, were used for statistical analyses of the data. RESULTS Compared to the gingiva of the neighbouring teeth, the peri-implant soft tissue around titanium and zirconia (test group), showed distinguishable ΔE both before and after crown cementation. Colour differences around titanium were statistically significant different (P = 0.01) only at 1 mm prior to crown cementation compared to zirconia. Compared to the gingiva of the neighbouring teeth, statistically significant (P < 0.01) differences were found for all colour parameter, either before or after crown cementation for both abutments; more significant differences were registered for titanium abutments. Tissue thickness correlated positively with c*-values for titanium at 1 mm and 2 mm from the gingival margin. CONCLUSIONS Within their limits, the present data indicate that: (i) The peri-implant soft tissue around titanium and zirconia showed colour differences when compared to the soft tissue around natural teeth, and (ii) the peri-implant soft tissue around zirconia demonstrated a better colour match to the soft tissue at natural teeth than titanium.
Collapse
Affiliation(s)
- Raluca Cosgarea
- Department of Periodontology, Philipps University Marburg, Marburg, Germany; Department of Prosthodontics, University Iuliu Hatieganu, Cluj-Napoca, Romania; Department of Periodontology, Dental School, University of Bern, Bern, Switzerland
| | | | | | | | | | | |
Collapse
|