1
|
Bukke AN, Midha N, Mahalingam K, Beri N, Angmo D, Sharma N, Pandey S, Dada T. Outcomes of bent ab interno needle goniectomy with phacoemulsification in moderate to severe primary open angle glaucoma. Indian J Ophthalmol 2024; 72:1280-1284. [PMID: 38990629 PMCID: PMC11552815 DOI: 10.4103/ijo.ijo_1072_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Accepted: 06/03/2024] [Indexed: 07/12/2024] Open
Abstract
PURPOSE To assess the safety and efficacy of bent ab interno needle goniectomy (BANG) in moderate to severe primary open angle glaucoma (POAG) eyes undergoing phacoemulsification (phaco). DESIGN Single-arm, prospective, interventional study. METHODS POAG patients with medically uncontrolled intraocular pressure (IOP), >15 mmHg for moderate and >12 mmHg for severe POAG, with visually significant cataract were recruited. All patients underwent BANG using a 26-gauge needle to excise 30° of the trabecular meshwork, along with phaco. Primary outcome was IOP. Secondary outcomes were success rate, percentage reduction in IOP/antiglaucoma medications (AGMs), and intraoperative complications. Success at 12 months was defined as: criterion A: IOP <15 mmHg for moderate glaucoma or <12 mmHg for severe glaucoma with or without AGMs OR criterion B: reduction in number of AGMs by >1. RESULTS Thirty-two eyes of 32 patients underwent BANG + phaco. Mean age of the participants was 62.7 ± 8.4 years and there were 25 males and seven females. At 12 months, a significant decrease was noted in both IOP (from 17.6 ± 3.6 to 12 ± 1.6 mmHg, 31.8%; P < 0.001) and AGMs (from 3.7 ± 0.9 to 2.8 ± 0.8, 24.3%; P < 0.001). Twenty percent or more reduction in IOP was achieved in 62.5% (20/32) of eyes. Overall success (meeting either of the criteria A or B) at 12 months was achieved in 87.5% eyes. Mild postoperative hyphema was noted in 10 (31.2%) eyes, and two eyes (6.2%) required additional filtration surgery at 7 months. CONCLUSION A 30-degree BANG with phaco in patients of POAG appears to be a safe, effective and affordable MIGS for developing countries.
Collapse
Affiliation(s)
- Anand N Bukke
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, India
| | - Neha Midha
- Avantika Eye Care and Glaucoma Services, New Delhi, India
| | | | - Nitika Beri
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, India
| | - Dewang Angmo
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, India
| | - Namrata Sharma
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, India
| | - Shivam Pandey
- Department of Biostatistics, All India Institute of Medical Sciences, New Delhi, India
| | - Tanuj Dada
- Dr. Rajendra Prasad Centre for Ophthalmic Sciences, AIIMS, Delhi, India
| |
Collapse
|
3
|
Ni L, Zhang W, Kim W, Warchock A, Bicket A, Wang X, Moroi SE, Argento A, Xu G. 3D imaging of aqueous veins and surrounding sclera using a dual-wavelength photoacoustic microscopy. BIOMEDICAL OPTICS EXPRESS 2023; 14:6291-6300. [PMID: 38420307 PMCID: PMC10898558 DOI: 10.1364/boe.505288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 10/24/2023] [Accepted: 10/24/2023] [Indexed: 03/02/2024]
Abstract
Understanding aqueous outflow resistance at the level of aqueous veins has been a challenge to the management of glaucoma. This study investigated resolving the anatomies of aqueous veins and the textures of surrounding sclera using photoacoustic microscopy (PAM). A dual wavelength PAM system was established and validated using imaging phantoms, porcine and human globes perfused with an optical contrast agent ex vivo. The system shows lateral resolution of 8.23 µm and 4.70 µm at 1200 nm and 532 nm, respectively, and an axial resolution of 27.6 µm. The system is able to separately distinguish the aqueous veins and the sclera with high contrast in full circumference of the porcine and human globes.
Collapse
Affiliation(s)
- Linyu Ni
- Department of Ophthalmology and Visual Sciences, Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
- Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - Wei Zhang
- Department of Ophthalmology and Visual Sciences, Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
- Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - Wonsuk Kim
- Department of Mechanical Engineering, University of Michigan-Dearborn, 4901 Evergreen Road, Dearborn, MI 48128, USA
| | - Alexus Warchock
- Department of Ophthalmology and Visual Sciences, Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
- Department of Mechanical Engineering, University of Michigan-Dearborn, 4901 Evergreen Road, Dearborn, MI 48128, USA
| | - Amanda Bicket
- Department of Ophthalmology and Visual Sciences, Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - Xueding Wang
- Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
- Department of Radiology, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - Sayoko E. Moroi
- Department of Ophthalmology and Visual Sciences, Havener Eye Institute, The Ohio State University Wexner Medical Center, Columbus, OH 43210, USA
| | - Alan Argento
- Department of Mechanical Engineering, University of Michigan-Dearborn, 4901 Evergreen Road, Dearborn, MI 48128, USA
| | - Guan Xu
- Department of Ophthalmology and Visual Sciences, Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
- Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| |
Collapse
|