1
|
Yıldız K, Kir M, Prencuva P, Genc HZ, Celiktepe V, Bozyer HE, Akcura YD, Bardak H, Bayam YS, Unal N. Transcatheter Patent Ductus Arteriosus Closure in Children With Different Devices and Long-Term Results. Cureus 2023; 15:e46504. [PMID: 37808606 PMCID: PMC10551573 DOI: 10.7759/cureus.46504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/04/2023] [Indexed: 10/10/2023] Open
Abstract
INTRODUCTION With the development of transcatheter interventional techniques and the introduction of next-generation duct occluder devices, transcatheter closure has become the first treatment option for patent ductus arteriosus (PDA) in pediatric patients. In this study, we compared the effectiveness and safety of different devices for transcatheter PDA closure in pediatric patients, focusing on long-term outcomes. METHODS A total of 235 patients aged 0-18 years who underwent transcatheter PDA closure at a tertiary care center between January 2005 and February 2020 were included. The medical records of the cases were retrospectively evaluated. RESULTS The median age of the patients was 2.3 years (range: 3.5 months to 17 years), with a mean weight of 12.8 kg (range: 5.7-43.2 kg). The mean PDA diameter at its narrowest point was 2.9 mm (range: 2.2-5.1 mm). Ductal anatomy was as follows: Type A in 98 (41.7%) patients, Type E in 36 (15.6%) patients, Type C in 32 (13.5%) patients, Type F in 27 (11.4%) patients, Type D in 23 (9.7%) patients, and Type B in 19 (8.1%) patients. Arterial access was used in 138 (57.1%) patients, venous + arterial access in 58 (24.6%) patients, and venous access only in 39 (16.5%) patients. Closure was performed with Amplatzer Duct Occluder (ADO; AGA Medical Corp., Golden Valley, MN, USA) II in 151 (64.2%) cases, ADO I in 43 (18.2%) cases, and coils in 41 (17.4%) cases. The mean fluoroscopy time and mean procedural time were 10.3 ± 4.2 minutes and 41 ± 7.2 minutes, respectively. The mean radiation dose was 1364 ± 497 cGy/min. The early closure rate after the procedure was 92%, while residual shunting on the first day post-procedure was observed in 1.8% of cases, decreasing to 0.1% at the one-month follow-up. The overall procedural success rate for all cases was 96.0%. The mean follow-up duration was 9.7 years (range: 2.9-13.8 years). CONCLUSION For percutaneous PDA closure, ADO I devices are preferred for larger defects, whereas ADO II devices are prioritized for small- to medium-sized defects instead of coils.
Collapse
Affiliation(s)
- Kaan Yıldız
- Pediatric Cardiology, Dokuz Eylul University Faculty of Medicine, Izmir, TUR
| | - Mustafa Kir
- Pediatric Cardiology, Dokuz Eylul University Faculty of Medicine, Izmir, TUR
| | - Pinar Prencuva
- Pediatrics, Dokuz Eylul University Faculty of Medicine, Izmir, TUR
| | - Halise Z Genc
- Pediatric Cardiology, Dokuz Eylul University Faculty of Medicine, Izmir, TUR
| | - Veysel Celiktepe
- Pediatric Cardiology, Dokuz Eylul University Faculty of Medicine, Izmir, TUR
| | - Hazer E Bozyer
- Pediatric Cardiology, Dokuz Eylul University Faculty of Medicine, Izmir, TUR
| | - Yagmur D Akcura
- Pediatric Cardiology, Dokuz Eylul University Faculty of Medicine, Izmir, TUR
| | - Huseyin Bardak
- Pediatric Cardiology, Dokuz Eylul University Faculty of Medicine, Izmir, TUR
| | - Yunus S Bayam
- Pediatrics, Dokuz Eylul University Faculty of Medicine, Izmir, TUR
| | - Nurettin Unal
- Pediatric Cardiology, Dokuz Eylul University Faculty of Medicine, Izmir, TUR
| |
Collapse
|
2
|
Transcatheter device closure of patent ductus arteriosus by exclusive venous access under echocardiographic guidance without angiography. Cardiol Young 2022; 32:55-59. [PMID: 33896438 DOI: 10.1017/s104795112100158x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
INTRODUCTION The standard transcatheter technique to profile the patent ductus arteriosus requires arterial access through the femoral artery and is associated with arterial complications, longer fluoroscopic time, contrast volume, and longer hospital stay. AIM OF THE STUDY To compare exclusive transvenous access with the standard procedures for patent ductus arteriosus closure and evaluate whether exclusive venous approach is a safe and effective alternative. METHODS A total of 320 patients were included. A detailed echocardiographic evaluation of the duct morphology was performed. Patients were classified into group 1 included patients who underwent exclusive femoral venous access, without any injections of contrast media and group 2 included patients who underwent arterial and venous access. RESULTS Arterial access was achieved in 210 (65.6%). Successful closure of patent ductus arteriosus was achieved in 109 (99.1%) patients in group 1 and in 203 (96.7%) patients in group 2. The patent ductus arteriosus was large and was referred for surgical closure in one patient from group 1 and 7 patients from group 2. Residual patent ductus arteriosus was seen in 6 cases from group 1 (5.4%) and 12 patients from group 2 (5.7%). None of the cases in group 1 had vascular complications, while vascular complications were seen in 20 cases, all of them in group 2 (9.5%). Nonvascular complications were seen in one patient from group 1 (0.9%) and 15 patients in group 2 (7.1%). The procedure time and fluoroscopy times were less in patients with exclusive transvenous access. CONCLUSION Patent ductus arteriosus device closure without arterial access can be accomplished safely and effectively.
Collapse
|
3
|
Percutaneous Closure of Patent Ductus Arteriosus in Infants 1.5 kg or Less: A Meta-Analysis. J Pediatr 2021; 230:84-92.e14. [PMID: 33098843 DOI: 10.1016/j.jpeds.2020.10.035] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 10/15/2020] [Accepted: 10/16/2020] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To investigate technical success and safety of percutaneous patent ductus arteriosus closure in infants ≤1.5 kg. STUDY DESIGN A systematic review and meta-analysis was performed. Data sources included Scopus, Web of Science, Embase, CINAHL, Cochrane, and PubMed from inception to April 2020. Publications were included if they had a clear definition of the intervention as percutaneous patent ductus arteriosus closure in infants ≤1.5 kg. Data extraction was independently performed by multiple observers. Primary outcome was technical success and secondary outcomes were adverse events (AEs). Subgroup analysis was performed in infants ≤6.0 kg. Data were pooled by using a random-effects model. RESULTS We included 28 studies, including 373 infants ≤1.5 kg and 69 studies enrolling 1794 infants ≤6.0 kg. In patients ≤1.5 kg, technical success was 96% (95% CI, 93%-98%; P = .16; I2 = 23%). The overall incidence of AE was 27% (95% CI, 17%-38%; P < .001; I2 = 70%) and major AEs was 8% (95% CI, 5%-10%; P = .63; I2 = 0%). There were 5 deaths related to the procedure (2%; 95% CI, 1%-4%; P = .99; I2 = 0%); 4 of these deaths occurred in infants <0.8 kg. The probability of technical failure was inversely related to age at the time of the procedure (OR, 0.9; 95% CI, 0.830-0.974; P = .009). Weight at intervention has decreased over time and procedural success has increased. CONCLUSIONS Percutaneous patent ductus arteriosus closure is feasible in infants ≤1.5 kg with few major AEs. The procedural success rate is high, despite performing the intervention in smaller patients. PROSPERO REGISTRATION CRD42020145230.
Collapse
|
4
|
Uppal L, Rohit MK, Barwad P, Naganur S, Debi U, Kasinadhuni G, Santosh K, Cr P, Sahoo S. Comparison of isolated venous approach with the standard approach in children undergoing patent ductus arteriosus device closure. Egypt Heart J 2020; 72:65. [PMID: 32990909 PMCID: PMC7524916 DOI: 10.1186/s43044-020-00100-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 09/21/2020] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND Transcatheter device closure is a safe procedure recommended in children with patent ductus arteriosus (PDA). While the standard procedure uses arterial and venous femoral access, it poses risk of vascular complications especially in young infants. Isolated venous approach has been tried in a few studies and was found to be non-inferior to the standard technique. In this prospective observational study, we have compared the two vascular approaches of PDA device closure in pediatric patients and have also studied the feasibility of this approach in young children with weight < 6 kg. RESULTS PDA device occlusion was performed with either one of the approaches-venous alone (group I) or standard approach (group II) in a total of 135 children enrolled prospectively. The baseline data, procedural outcomes, vascular complications, and radiation dose were compared between the two groups. Fifty-two and 83 children were included in group I and group II, respectively. A total of 22 children (16%) (13 in group I; 9 in group II) had weight < 6 kg. In group II, 6 children (7.2%) had vascular site complications treated with heparin infusion with two children requiring thrombolysis. Another child in group II developed intravascular hemolysis following residual shunt, requiring surgical device retrieval and closure. No significant differences were observed in mean fluoroscopic time (p = 0.472) and air kerma between the two groups (p = 0.989). CONCLUSION Transcatheter PDA device closure without arterial access is a feasible and safe option in children including young infants. This technique avoids the risk of vascular complications although requires careful case selection.
Collapse
Affiliation(s)
- Lipi Uppal
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Manoj Kumar Rohit
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India.
| | - Parag Barwad
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Sanjeev Naganur
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Uma Debi
- Department of Radiodiagnosis, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Ganesh Kasinadhuni
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Krishna Santosh
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Pruthvi Cr
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | - Saroj Sahoo
- Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, 160012, India
| |
Collapse
|
5
|
Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus. Anatol J Cardiol 2019; 20:30-34. [PMID: 29952360 PMCID: PMC6237790 DOI: 10.14744/anatoljcardiol.2018.90001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
Objective: We aimed to investigate the feasibility and safety of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus (PDA) without the use of X-ray equipment. Methods: From January to December 2015, we performed stand-alone transthoracic echocardiography-guided percutaneous PDA occlusion using an occluder delivered via a delivery sheath introduced via femoral vein access without the use of X-ray equipment in 12 PDA patients. Results: PDA occlusion was successfully performed in all 12 patients. The procedure duration ranged from 30 to 110 min (50.4±22.8 min), and the size of the implanted occluder ranged from 12 to 20 mm (15.2±2.8 mm). No occluder migration, residual shunt, or thrombotic complications were observed in the perioperative period. There was no clinical death, hemolysis, infection, or embolism during patients’ hospitalization and the follow-up period. Conclusion: Stand-alone transthoracic echocardiography-guided percutaneous PDA occlusion without the use of X-ray equipment is a safe and effective procedure.
Collapse
|
6
|
Liu J, Gao L, Tan HL, Zheng QH, Liu L, Wang Z. Transcatheter closure through single venous approach for young children with patent ductus arteriosus: A retrospective study of 686 cases. Medicine (Baltimore) 2018; 97:e11958. [PMID: 30170394 PMCID: PMC6393149 DOI: 10.1097/md.0000000000011958] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
The objective is to explore the feasibility and safety of transcatheter closure of patent ductus arteriosus (PDA) through single venous approach in Chinese young children.A total of 1088 patients aged between 9 months old to 3 years old who underwent transcatheter closure of PDA from May 2004 to May 2015 were retrospectively reviewed. All the procedures were under ultrasound monitoring. The shape and size of PDA as well as immediate therapeutic results were recorded by angiography and ultrasonography. The size of occluder was individually selected according to the smallest diameter of the PDAs. Echocardiography was respectively performed 3 days, 1month, 6 months, and 12 months after the procedure to evaluate the outcomes.Among the total 1088 children, transcatheter closure of PDA was accomplished through single venous approach that was performed in 686 cases. The average weight and age of the children were 10.9 ± 3.6 kg (5.0-14.3 kg) and 1.8 ± 1.6 years (9 months-3 years), respectively. The fluoroscopic time was about 5.1 to 11.6 minutes. Successful device placement with the initially selected occluder was achieved in 662 cases. In other 14 cases, the procedure was eventually completed after being replaced with a larger occluder; while in the other 10 cases, smaller occluders were applied to replace the initial ones. Technically, all the procedures were successfully performed. All the patients were followed up for 15.6 ± 8.2 years. No serious complications and death were observed during the follow-up.Transcatheter closure of PDA with occluder by single venous approach is an effective and reliable method in vast majority of young children.
Collapse
|
7
|
Bilici M, Demir F, Akın A, Türe M, Balık H, Kuyumcu M. Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder. Pediatr Cardiol 2017; 38:1598-1605. [PMID: 28828684 DOI: 10.1007/s00246-017-1702-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Accepted: 07/28/2017] [Indexed: 11/27/2022]
Abstract
The aim of this study was to evaluate the feasibility, efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with the Occlutech duct occluder (ODO) in children. We reviewed the clinical records of 71 patients who underwent percutaneous closure of PDA with an ODO between September 2014 and August 2016. The Occlutech duct occluder was applied to 71 patients during the study period (September 2014-August 2016), and the results were analyzed in this study. Forty-two of the patients were female and 29 male. The median age was 20.5 months (range, 6-194 months) and median weight was 16 kg (range, 6-68 kg). The PDA was classified as type A in 54 patients (76.1%), type E in 14 (19.7%), type C in 2 (2.8%) and type B in 1 (1.4%) based on the Krichenko classification. A standard ODO device was used for the transcatheter closure procedure in 66 patients and the long-shank ODO device in 5. In the echocardiographic measurement of PDA, the median smallest diameter was 2.7 mm (range, 1.5-7.0 mm), and in the angiographic measurement, the median smallest diameter was 2.5 mm (range, 1.5-6.5 mm). All 71 patients underwent successful PDA closure with the ODO. Angiography following the procedure showed complete closure in 47 patients (66.2%), mild residual shunt in 13 patients (18.3%) and a trivial shunt in 11 patients (15.5%). Color flow Doppler echocardiogpaphy at 24 h post-implantation showed that complete closure was achieved in 65 patients (91.5%), and 6 patients (8.5%) had mild residual shunt. All patients (100%) had complete closure at 30 days of follow-up. The results of this study showed that the Occlutech PDA occluder device is safe and effective in the closure of PDA. As the pulmonary artery side of the device is wider than the aortic side, protrusion toward the aortic side and embolization are prevented, but there is residual shunt in the early period, although this residual shunt disappeared after a few months.
Collapse
Affiliation(s)
- Meki Bilici
- Department of Pediatric Cardiology, Dicle University Medical Faculty, Sur, Diyarbakır, Turkey.
| | - Fikri Demir
- Department of Pediatric Cardiology, Dicle University Medical Faculty, Sur, Diyarbakır, Turkey
| | - Alper Akın
- Department of Pediatric Cardiology, Dicle University Medical Faculty, Sur, Diyarbakır, Turkey
| | - Mehmet Türe
- Department of Pediatric Cardiology, Dicle University Medical Faculty, Sur, Diyarbakır, Turkey
| | - Hasan Balık
- Department of Pediatric Cardiology, Dicle University Medical Faculty, Sur, Diyarbakır, Turkey
| | - Mahir Kuyumcu
- Department of Anesthesiology, Dicle University Medical Faculty, Sur, Diyarbakir, Turkey
| |
Collapse
|
8
|
Backes CH, Rivera BK, Bridge JA, Armstrong AK, Boe BA, Berman DP, Fick T, Holzer RJ, Hijazi ZM, Abadir S, Justino H, Bergersen L, Smith CV, Kirpalani H. Percutaneous Patent Ductus Arteriosus (PDA) Closure During Infancy: A Meta-analysis. Pediatrics 2017; 139:peds.2016-2927. [PMID: 28087683 DOI: 10.1542/peds.2016-2927] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/31/2016] [Indexed: 11/24/2022] Open
Abstract
CONTEXT Patent ductus arteriosus (PDA) is a precursor to morbidity and mortality. Percutaneous (catheter-based) closure is the procedure of choice for adults and older children with a PDA, but use during infancy (<1 year) is not well characterized. OBJECTIVE Investigate the technical success and safety of percutaneous PDA closure during infancy. DATA SOURCES Scopus, Web of Science, Embase, PubMed, and Ovid (Medline) were searched through December 2015 with no language restrictions. STUDY SELECTION Publications needed to clearly define the intervention as percutaneous PDA closure during infancy (<1 year of age at intervention) and must have reported adverse events (AEs). DATA EXTRACTION The study was performed according to the Systematic Reviews and Meta-Analysis checklist and registered prospectively. The quality of the selected studies was critically examined. Data extraction and assignment of AE attributability and severity were independently performed by multiple observers. Outcomes were agreed on a priori. Data were pooled by using a random-effects model. RESULTS Thirty-eight studies were included; no randomized controlled trials were found. Technical success of percutaneous PDA closure was 92.2% (95% confidence interval [CI] 88.8-95.0). Overall AE and clinically significant AE incidence was 23.3% (95% CI 16.5-30.8) and 10.1% (95% CI 7.8-12.5), respectively. Significant heterogeneity and publication bias were observed. LIMITATIONS Limitations include lack of comparative studies, lack of standardized AE reporting strategy, and significant heterogeneity in reporting. CONCLUSIONS Percutaneous PDA closure during infancy is feasible and associated with few catastrophic AEs; however, the limitations constrain the interpretability and generalizability of the current findings.
Collapse
Affiliation(s)
- Carl H Backes
- Centers for Perinatal Research, .,Cardiovascular and Pulmonary Research, and.,The Heart Center, The Research Institute at Nationwide Children's Hospital, Nationwide Children's Hospital, Columbus, Ohio.,Department of Pediatrics, The Ohio State University, Columbus, Ohio
| | | | - Jeffrey A Bridge
- Department of Pediatrics, The Ohio State University, Columbus, Ohio.,Innovation in Pediatric Practice, and
| | - Aimee K Armstrong
- Cardiovascular and Pulmonary Research, and.,The Heart Center, The Research Institute at Nationwide Children's Hospital, Nationwide Children's Hospital, Columbus, Ohio.,Department of Pediatrics, The Ohio State University, Columbus, Ohio
| | - Brian A Boe
- Cardiovascular and Pulmonary Research, and.,The Heart Center, The Research Institute at Nationwide Children's Hospital, Nationwide Children's Hospital, Columbus, Ohio.,Department of Pediatrics, The Ohio State University, Columbus, Ohio
| | - Darren P Berman
- Cardiovascular and Pulmonary Research, and.,The Heart Center, The Research Institute at Nationwide Children's Hospital, Nationwide Children's Hospital, Columbus, Ohio.,Department of Pediatrics, The Ohio State University, Columbus, Ohio
| | - Tyler Fick
- Department of Pediatrics, The Ohio State University, Columbus, Ohio
| | - Ralf J Holzer
- Department of Pediatrics, Weill Cornell Medical College, New York, New York.,Cardiac Catheterization and Interventional Therapy, Sidra Cardiac Program, Sidra Medical and Research Center, Doha, Qatar
| | - Ziyad M Hijazi
- Department of Pediatrics, Weill Cornell Medical College, New York, New York.,Cardiac Catheterization and Interventional Therapy, Sidra Cardiac Program, Sidra Medical and Research Center, Doha, Qatar
| | - Sylvia Abadir
- Department of Pediatric Cardiology, CHU mère-enfant Sainte-Justine, Université de Montréal, Quebec, Canada
| | - Henri Justino
- Section of Pediatric Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, Texas
| | - Lisa Bergersen
- Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts
| | - Charles V Smith
- Center for Developmental Therapeutics, Seattle Children's Research Institute, University of Washington School of Medicine, Seattle, Washington; and
| | - Haresh Kirpalani
- Division of Neonatology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania
| |
Collapse
|
9
|
Thanopoulos B(VD, Ninios V, Dardas P, Giannopoulos A, Deleanou D, Iancovici S. Catheter Closure Through a Venous Approach of Patent Ductus Arteriosus in Small Pediatric Patients Using Combined Angiographic and Echocardiographic Guidance. Am J Cardiol 2016; 118:1558-1562. [PMID: 27670796 DOI: 10.1016/j.amjcard.2016.08.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2016] [Revised: 08/09/2016] [Accepted: 08/09/2016] [Indexed: 10/21/2022]
Abstract
The standard technique of catheter closure of patent ductus arteriosus (PDA) may be associated with arterial complications particularly in small pediatric patients. The aim of this study was to evaluate whether catheter closure of PDA in small children using an exclusive venous approach is a safe and effective alternative to closure with the standard technique. One hundred-twelve patients, aged 2 to 24 months, were randomly assigned in a 1:1 ratio to catheter closure of PDA using the standard technique (group 1) and an exclusive venous approach (group 2), respectively. In group 2, the procedure was guided using hand injections of contrast media through the delivery sheath and 2-dimensional and color Doppler echocardiography. Group 1: the PDA diameter ranged from 2 to 5.5 mm and the device diameter ranged from 4 to 8 mm. The PDA occluders were permanently implanted in all patients. Five losses of the arterial pulses that were restored with intravenous infusion of heparin and recombinant tissue plasminogen activator (rtPA), and 4 groin hematomas were the main complications of the procedure. Group 2: the mean PDA diameter ranged from 2.5 to 6 mm and the device diameter ranged from 3 to 8 mm. The PDA occluders were permanently implanted in all but 2 patients. There were no complications. Complete echocardiographic closure of PDA at 1-month follow-up was observed in all 110 patients. Exclusive transvenous PDA occlusion is an effective and safe technique that prevents the arterial complications of the standard approach in small children.
Collapse
|
10
|
Abstract
Objective: Our hypothesis was that percutaneous PDA closure in babies less than 2 kg was a safe and effective method. The aim of this study is to share our experience in transcatheter PDA closure in infants whose body weight is less than 2 kg in order to support our hypothesis. Methods: Between July 1997 and October 2014, 382 percutaneous PDA closures were done in our center. Nineteen patients who weighed less than 2 kg were included in this retrospectively study. The other inclusion criteria were 1) being symptomatic and PDA was thought as a possible contributor of medical state and 2) persistence of PDA after medical closure treatment. Patients who had sepsis and bleeding diathesis were excluded. According to size and shape of PDA, different types of devices were used such as detachable coils and Amplatzer duct occluders. Data was expressed as mean (SD) or median (minimum–maximum). Comparisons of means and medians were performed with Student’s t-test and with Mann–Whitney U test, respectively. Results: The median patient age and weight were 32 days and 1603 g (range 910–2000 g) respectively. Mean PDA diameter was 3.2±1.3 mm. Morphology of PDA was type A in 7 patients, type C in 10, type E in 1, and type B in 1 patient. There were no reported major complications. Stenosis of left pulmonary artery was detected in four patients, all of which resolved in 6 months follow-up. Conclusion: Percutaneous PDA closure in babies less than 2 kg is a safe and effective method that can be an alternative to surgery. Main distinguishing feature of this study is that it includes the largest cohort of patients less than 2 kg whose PDA closed percutaneously.
Collapse
|
11
|
Abstract
Despite several reports describing echocardiography for the guidance of ductal closure, two-dimensional angiography remains the mainstay imaging tool; three-dimensional rotational angiography has the potential to overcome some of the drawbacks of standard angiography, and reconstructed image overlay provides reliable guidance for device placement. We describe arterial duct closure solely from venous approach guided by live three-dimensional image overlay.
Collapse
|
12
|
Thanopoulos BV. Do we need a femoral artery route for transvenous PDA closure in children with ADO I? Anatol J Cardiol 2015; 15:248. [PMID: 25880177 PMCID: PMC5337063 DOI: 10.5152/akd.2015.14638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|