1
|
Park HJ, Kim SY, Baik GH, Seo M, Seo HI, Park SC, Kim H, Kim HS. Efficacy of a novel one-step knife compared to conventional knife for colorectal endoscopic submucosal dissection: a prospective multicenter randomized controlled trial. Int J Colorectal Dis 2025; 40:116. [PMID: 40366393 DOI: 10.1007/s00384-025-04910-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/06/2025] [Indexed: 05/15/2025]
Abstract
PURPOSE For the treatment of advanced colorectal neoplasms, colon endoscopic submucosal dissection (ESD) is a crucial technique, although it is time-consuming. The purpose of this study was to evaluate the efficacy of a recently developed one-step knife (OSK) in colon ESD and compare its performance with that of a conventional knife (CK). METHODS Between July 2020 and November 2021, patients scheduled to undergo colorectal ESD were randomly assigned to either the OSK group or the CK group. The primary outcome was the total submucosal injection time. Additionally, total procedure time, treatment outcomes, adverse events, and operator convenience were analyzed. RESULTS Data from 53 patients (28 in the OSK group and 25 in the CK group) were analyzed. The mean total injection time was lower in the OSK group than in the CK group (186 s [IQR, 116.8-249.5] vs. 265 s [IQR, 130.5-553.0]), but the difference was not statistically significant (P = 0.082). The total procedure time tended to be shorter in the OSK group than in the CK group (15.5 min [IQR, 11.3-22.8] vs. 20 min [IQR, 13.5-42.5], P = 0.110). Resection rates and adverse events did not differ between the two groups. A greater proportion of endoscopists expressed high satisfaction with the OSK, particularly regarding submucosal injection. CONCLUSION Compared to the CK, OSK use led to shorter injection and procedure times, though not statistically significant. The use of this newly developed endoscopic knife can potentially enhance the effectiveness and efficiency of colorectal ESD (Clinical Research Information Service: KCT0005123).
Collapse
Affiliation(s)
- Hong Jun Park
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University Wonju College of Medicine, 20 Ilsan-Ro, Wonju, 26426, Republic of Korea
| | - Su Young Kim
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University Wonju College of Medicine, 20 Ilsan-Ro, Wonju, 26426, Republic of Korea.
| | - Gwang Ho Baik
- Department of Internal Medicine, Hallym University College of Medicine, Chuncheon, Korea
| | - Myeongsook Seo
- Department of Gastroenterology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Republic of Korea
| | - Hyun Il Seo
- Department of Gastroenterology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Republic of Korea
| | - Sung Chul Park
- Department of Internal Medicine, Kangwon National University College of Medicine, Chuncheon, Republic of Korea
| | - Hyunil Kim
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University Wonju College of Medicine, 20 Ilsan-Ro, Wonju, 26426, Republic of Korea
| | - Hyun-Soo Kim
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University Wonju College of Medicine, 20 Ilsan-Ro, Wonju, 26426, Republic of Korea
| |
Collapse
|
2
|
Cocomazzi F, Carparelli S, Labarile N, Capogreco A, Gentile M, Maselli R, Dhar J, Samanta J, Repici A, Hassan C, Perri F, Facciorusso A. Is there a best choice of equipment for colorectal endoscopic submucosal dissection? Expert Rev Med Devices 2024; 21:561-577. [PMID: 38829122 DOI: 10.1080/17434440.2024.2364022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Accepted: 05/31/2024] [Indexed: 06/05/2024]
Abstract
INTRODUCTION Endoscopic submucosal dissection (ESD) is a widely used technique to remove early neoplastic lesions. It was primarily used in the initial days to treat gastric lesions, but recently, the horizon of this endoscopic procedure has expanded, which has allowed us to manage other technically more complex locations, such as the colorectum. AREAS COVERED There has been an exponential growth regarding the wide range of devices available in the market for performing colorectal ESD. As a result, the aim of this review is to highlight the indication of this endoscopic technique, which device is best suited for which indication, as well as future trajectories in this field. EXPERT OPINION Although some devices have proven to be more advantageous than others in this area, very often the choice is still subjective, which is commonly attributed to individual preferences and experience. However, an accurate knowledge of the available tools and their functioning, with their pros and cons, is fundamental for any endoscopist venturing into the field of third space endoscopy. In this way, one can choose which device best suits a particular situation, along with simultaneously having the wealth of knowledge related to therapeutic armamentarium at our disposal in the endoscopy suite.
Collapse
Affiliation(s)
- Francesco Cocomazzi
- Gastroenterology and Endoscopy Unit, Fondazione "Casa Sollievo della Sofferenza", IRCCS, San Giovanni Rotondo, Foggia, Italy
| | - Sonia Carparelli
- Gastroenterology and Endoscopy Unit, Fondazione "Casa Sollievo della Sofferenza", IRCCS, San Giovanni Rotondo, Foggia, Italy
| | - Nunzia Labarile
- Department of Gastroenterology, National Institute of Gastroenterology - IRCCS "Saverio de Bellis" - Castellana Grotte, Bari, Italy
| | - Antonio Capogreco
- Endoscopy Unit, Humanitas Clinical and Research Center - IRCCS - Rozzano, Rozzano, Italy
| | - Marco Gentile
- Gastroenterology and Endoscopy Unit, Fondazione "Casa Sollievo della Sofferenza", IRCCS, San Giovanni Rotondo, Foggia, Italy
| | - Roberta Maselli
- Endoscopy Unit, Humanitas Clinical and Research Center - IRCCS - Rozzano, Rozzano, Italy
- Department of Biomedical Sciences, Humanitas University - Rozzano, Foggia, Italy
| | - Jahnvi Dhar
- Department of Gastroenterology, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Jayanta Samanta
- Department of Gastroenterology, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Alessandro Repici
- Endoscopy Unit, Humanitas Clinical and Research Center - IRCCS - Rozzano, Rozzano, Italy
- Department of Biomedical Sciences, Humanitas University - Rozzano, Foggia, Italy
| | - Cesare Hassan
- Endoscopy Unit, Humanitas Clinical and Research Center - IRCCS - Rozzano, Rozzano, Italy
- Department of Biomedical Sciences, Humanitas University - Rozzano, Foggia, Italy
| | - Francesco Perri
- Gastroenterology and Endoscopy Unit, Fondazione "Casa Sollievo della Sofferenza", IRCCS, San Giovanni Rotondo, Foggia, Italy
| | | |
Collapse
|
3
|
Jacques J, Neuhaus H, Enderle MD, Biber U, Linzenbold W, Schenk M, Khalaf K, Repici A. Colorectal Endoscopic Submucosal Dissection: Performance of a Novel Hybrid-Technology Knife in an Animal Trial. Diagnostics (Basel) 2023; 13:3347. [PMID: 37958243 PMCID: PMC10650536 DOI: 10.3390/diagnostics13213347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 10/18/2023] [Accepted: 10/26/2023] [Indexed: 11/15/2023] Open
Abstract
Endoscopic submucosal dissection (ESD) was developed for the removal of benign and early malignant lesions in the gastrointestinal tract. We aimed to evaluate the performance and safety of a novel high-pressure waterjet-assisted ESD knife in colorectal applications. Six female German Landrace pigs with an average weight of 62 kg (range 60-65 kg) were used in this prospective, randomized, and controlled study. Twenty-four ESDs were performed by three endoscopists: Twelve each with the new Erbe HYBRIDknife® flex T-Type (HK-T) and the Olympus DualKnife® J (DK-J), including six rectal and six colonic ESDs per instrument. The order of performance was randomized regarding anatomic position and instrument. As the primary endpoint, ESD knife performance characteristics were combined and rated on a 5-point Likert scale, with 5 Likert points (LP) representing the best response (5 = very good). The HK-T was rated significantly better than the DK-J (4.7 LP versus 4.4 LP, p = 0.0295), mainly because of HK-T injection ability (5 LP versus 3 LP, p < 0.0001) and hemostasis (5 LP versus 4 LP, p = 0.0452). There was no difference in procedure time (HK-T: 35 min versus DK-J: 34 min, p = 0.8005), resection diameter (3.1 cm versus 2.8 cm, p = 0.3492), injection volume (41 mL versus 46 mL, p = 0.5633), and complication rates. HK-T is as effective as DK-J in colorectal ESD in terms of dissection quality but has better injection and hemostatic properties. The impact of these technical advantages on the ESD treatment of patients with large superficial colorectal lesions remains to be clinically verified.
Collapse
Affiliation(s)
- Jérémie Jacques
- Department of Hepato-Gastro-Enterology, University Hospital Center, 87042 Limoges, France
| | - Horst Neuhaus
- Medical Clinic for Gastroenterology at the Hospital Duesseldorf, 40225 Duesseldorf, Germany
| | | | - Ulrich Biber
- Erbe Elektromedizin GmbH, 72072 Tuebingen, Germany
| | | | - Martin Schenk
- Department of Experimental Medicine, University Hospital Tuebingen, 72076 Tuebingen, Germany
| | - Kareem Khalaf
- Endoscopy Unit, Humanitas Clinical and Research Center IRCCS, 20089 Milan, Italy
- Department of Biomedical Science, Humanitas University, 20072 Milan, Italy
| | - Alessandro Repici
- Endoscopy Unit, Humanitas Clinical and Research Center IRCCS, 20089 Milan, Italy
- Department of Biomedical Science, Humanitas University, 20072 Milan, Italy
| |
Collapse
|
4
|
John S. Waterjet-assisted endoscopic submucosal dissection in the colorectum: safe and effective? Clin Endosc 2022; 55:755-756. [PMID: 36464823 PMCID: PMC9726437 DOI: 10.5946/ce.2022.271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Accepted: 11/14/2022] [Indexed: 11/30/2022] Open
Affiliation(s)
- Sneha John
- Endoscopy, Gold Coast University Hospital, Southport, Australia,Correspondence: Sneha John Endoscopy, Gold Coast University Hospital, Southport, Australia E-mail:
| |
Collapse
|