Chen X, Hendrik Pretorius P, Zhou B, Liu H, Johnson K, Liu YH, King MA, Liu C. Cross-vender, cross-tracer, and cross-protocol deep transfer learning for attenuation map generation of cardiac SPECT. J Nucl Cardiol 2022; 29:3379-3391. [PMID: 35474443 PMCID: PMC11407548 DOI: 10.1007/s12350-022-02978-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 03/28/2022] [Indexed: 01/18/2023]
Abstract
It has been proved feasible to generate attenuation maps (μ-maps) from cardiac SPECT using deep learning. However, this assumed that the training and testing datasets were acquired using the same scanner, tracer, and protocol. We investigated a robust generation of CT-derived μ-maps from cardiac SPECT acquired by different scanners, tracers, and protocols from the training data. We first pre-trained a network using 120 studies injected with 99mTc-tetrofosmin acquired from a GE 850 SPECT/CT with 360-degree gantry rotation, which was then fine-tuned and tested using 80 studies injected with 99mTc-sestamibi acquired from a Philips BrightView SPECT/CT with 180-degree gantry rotation. The error between ground-truth and predicted μ-maps by transfer learning was 5.13 ± 7.02%, as compared to 8.24 ± 5.01% by direct transition without fine-tuning and 6.45 ± 5.75% by limited-sample training. The error between ground-truth and reconstructed images with predicted μ-maps by transfer learning was 1.11 ± 1.57%, as compared to 1.72 ± 1.63% by direct transition and 1.68 ± 1.21% by limited-sample training. It is feasible to apply a network pre-trained by a large amount of data from one scanner to data acquired by another scanner using different tracers and protocols, with proper transfer learning.
Collapse
Affiliation(s)
- Xiongchao Chen
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - P Hendrik Pretorius
- Department of Radiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, MA, 01655, USA
| | - Bo Zhou
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Hui Liu
- Department of Radiology and Biomedical Imaging, Yale University, PO Box 208048, New Haven, CT, 06520, USA
- Department of Engineering Physics, Tsinghua University, Beijing, People's Republic of China
| | - Karen Johnson
- Department of Radiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, MA, 01655, USA
| | - Yi-Hwa Liu
- Department of Internal Medicine (Cardiology), Yale University, New Haven, CT, USA
- Department of Biomedical Imaging and Radiological Sciences, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Michael A King
- Department of Radiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, MA, 01655, USA.
| | - Chi Liu
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
- Department of Radiology and Biomedical Imaging, Yale University, PO Box 208048, New Haven, CT, 06520, USA.
| |
Collapse
|
2
|
Chen X, Zhou B, Xie H, Shi L, Liu H, Holler W, Lin M, Liu YH, Miller EJ, Sinusas AJ, Liu C. Direct and indirect strategies of deep-learning-based attenuation correction for general purpose and dedicated cardiac SPECT. Eur J Nucl Med Mol Imaging 2022; 49:3046-3060. [PMID: 35169887 PMCID: PMC9253078 DOI: 10.1007/s00259-022-05718-8] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 02/06/2022] [Indexed: 12/22/2022]
Abstract
PURPOSE Deep-learning-based attenuation correction (AC) for SPECT includes both indirect and direct approaches. Indirect approaches generate attenuation maps (μ-maps) from emission images, while direct approaches predict AC images directly from non-attenuation-corrected (NAC) images without μ-maps. For dedicated cardiac SPECT scanners with CZT detectors, indirect approaches are challenging due to the limited field-of-view (FOV). In this work, we aim to 1) first develop novel indirect approaches to improve the AC performance for dedicated SPECT; and 2) compare the AC performance between direct and indirect approaches for both general purpose and dedicated SPECT. METHODS For dedicated SPECT, we developed strategies to predict truncated μ-maps from NAC images reconstructed with a small matrix, or full μ-maps from NAC images reconstructed with a large matrix using 270 anonymized clinical studies scanned on a GE Discovery NM/CT 570c SPECT/CT. For general purpose SPECT, we implemented direct and indirect approaches using 400 anonymized clinical studies scanned on a GE NM/CT 850c SPECT/CT. NAC images in both photopeak and scatter windows were input to predict μ-maps or AC images. RESULTS For dedicated SPECT, the averaged normalized mean square error (NMSE) using our proposed strategies with full μ-maps was 1.20 ± 0.72% as compared to 2.21 ± 1.17% using the previous direct approaches. The polar map absolute percent error (APE) using our approaches was 3.24 ± 2.79% (R2 = 0.9499) as compared to 4.77 ± 3.96% (R2 = 0.9213) using direct approaches. For general purpose SPECT, the averaged NMSE of the predicted AC images using the direct approaches was 2.57 ± 1.06% as compared to 1.37 ± 1.16% using the indirect approaches. CONCLUSIONS We developed strategies of generating μ-maps for dedicated cardiac SPECT with small FOV. For both general purpose and dedicated SPECT, indirect approaches showed superior performance of AC than direct approaches.
Collapse
Affiliation(s)
- Xiongchao Chen
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Bo Zhou
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Huidong Xie
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Luyao Shi
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Hui Liu
- Department of Radiology and Biomedical Imaging, Yale University, CT, New Haven, USA
- Department of Engineering Physics, Tsinghua University, Beijing, People's Republic of China
| | | | - MingDe Lin
- Department of Radiology and Biomedical Imaging, Yale University, CT, New Haven, USA
- Visage Imaging, Inc, San Diego, CA, USA
| | - Yi-Hwa Liu
- Department of Internal Medicine (Cardiology), Yale University School of Medicine, New Haven, CT, USA
- Department of Biomedical Imaging and Radiological Sciences, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Edward J Miller
- Department of Radiology and Biomedical Imaging, Yale University, CT, New Haven, USA
- Department of Internal Medicine (Cardiology), Yale University School of Medicine, New Haven, CT, USA
| | - Albert J Sinusas
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
- Department of Radiology and Biomedical Imaging, Yale University, CT, New Haven, USA
- Department of Internal Medicine (Cardiology), Yale University School of Medicine, New Haven, CT, USA
| | - Chi Liu
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
- Department of Radiology and Biomedical Imaging, Yale University, CT, New Haven, USA.
| |
Collapse
|
3
|
Khan J, Rydèn T, Van Essen M, Svensson J, Bernhardt P. ACTIVITY CONCENTRATION ESTIMATION IN AUTOMATED KIDNEY SEGMENTATION BASED ON CONVOLUTION NEURAL NETWORK METHOD FOR 177LU-SPECT/CT KIDNEY DOSIMETRY. RADIATION PROTECTION DOSIMETRY 2021; 195:164-171. [PMID: 34080002 DOI: 10.1093/rpd/ncab079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 04/28/2021] [Accepted: 04/30/2021] [Indexed: 06/12/2023]
Abstract
For 177Lu-DOTATATE treatments, dosimetry based on manual kidney segmentation from computed tomography (CT) is accurate but time consuming and might be affected by misregistration between CT and SPECT images. This study develops a convolution neural network (CNN) for automated kidney segmentation that accurately aligns CT segmented volume of interest (VOI) to the kidneys in SPECT images. The CNN was trained with SPECT/CT images performed over the abdominal area of 137 patients treated with 177Lu-DOTATATE. Activity concentrations in automated and manual segmentations were strongly correlated for both kidneys (r > 0.96, p < 0.01) in the testing cohort (n = 20). The Bland-Altman analyses demonstrated higher accuracy for the CNN segmentation compared to the manual segmented kidneys without VOI adjustment. The CNN demonstrated a potential for accurate kidney segmentation. The CNN was a fast and robust approach for assessment of activity concentrations in SPECT images, and performed equally well as the manual segmentation method.
Collapse
Affiliation(s)
- Jehangir Khan
- Department of Medical Physics and Biomedical Engineering (MFT), Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Tobias Rydèn
- Department of Medical Physics and Biomedical Engineering (MFT), Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Martijn Van Essen
- Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Johanna Svensson
- Department of Oncology, Institution of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden
| | - Peter Bernhardt
- Department of Medical Physics and Biomedical Engineering (MFT), Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Sweden
| |
Collapse
|