1
|
Hung CH, Kwok YC, Yip J, Wong HH, Leung YY. Bioabsorbable Magnesium-Based Materials Potential and Safety in Bone Surgery: A Systematic Review. Craniomaxillofac Trauma Reconstr 2025; 18:24. [PMID: 40276521 PMCID: PMC12015880 DOI: 10.3390/cmtr18020024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2024] [Revised: 03/28/2025] [Accepted: 04/01/2025] [Indexed: 04/26/2025] Open
Abstract
The goal of this study was to evaluate the clinical outcomes, safety, and clinical applications of bioabsorbable magnesium-based materials for fixation in bone surgeries. The review was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. An initial search was performed on electronic databases, followed by manual and reference searches. The articles selected were evaluated for patient characteristics, biocompatibility, the need for revision surgery, bone union rates, and the incidence of gas formation associated with implant degradation. Out of the 631 initially identified articles, 8 studies including a total of 386 patients were included in the final qualitative analysis. The magnesium (Mg) group carried a lower rate of revision surgery (1/275) when compared to the titanium (Ti) group (18/111). A high rate of bone union was found in the Mg group and a low infection rate (3/275) was found in the Mg group. The serum level of Mg and calcium (Ca) were not found to be affected. Mg implants are applied in various orthopedic surgeries but they are not applied in in oral or maxillofacial surgeries. Mg implants appear to be a safe alternative for bone fixation and are resorbable. Future research into the application of Mg implants in bone fixation in different anatomical sites is essential to fully harness their potential benefits for patients.
Collapse
Affiliation(s)
- Chun Ho Hung
- Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China; (C.H.H.); (Y.C.K.); (J.Y.); (H.H.W.)
| | - Yui Chit Kwok
- Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China; (C.H.H.); (Y.C.K.); (J.Y.); (H.H.W.)
| | - Jason Yip
- Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China; (C.H.H.); (Y.C.K.); (J.Y.); (H.H.W.)
| | - Ho Hin Wong
- Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China; (C.H.H.); (Y.C.K.); (J.Y.); (H.H.W.)
| | - Yiu Yan Leung
- Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China; (C.H.H.); (Y.C.K.); (J.Y.); (H.H.W.)
| |
Collapse
|
2
|
Fang C, Premchand AXR, Park DH, Toon DH. Peri-articular elbow fracture fixations with magnesium implants and a review of current literature: A case series. World J Orthop 2024; 15:215-229. [PMID: 38596190 PMCID: PMC10999966 DOI: 10.5312/wjo.v15.i3.215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Revised: 01/11/2024] [Accepted: 02/02/2024] [Indexed: 03/15/2024] Open
Abstract
BACKGROUND In recent years, the use of Magnesium alloy implants have gained renewed popularity, especially after the first commercially available Conformité Européenne approved Magnesium implant became available (MAGNEZIX® CS, Syntellix) in 2013. AIM To document our clinical and radiographical outcomes using magnesium implants in treating peri-articular elbow fractures. METHODS Our paper was based on a retrospective case series design. Intra-operatively, a standardized surgical technique was utilized for insertion of the magnesium implants. Post - operatively, clinic visits were standardized and physical exam findings, functional scores, and radiographs were obtained at each visit. All complications were recorded. RESULTS Five patients with 6 fractures were recruited (2 coronoid, 3 radial head and 1 capitellum). The mean patient age and length of follow up was 54.6 years and 11 months respectively. All fractures healed, and none exhibited loss of reduction or complications requiring revision surgery. No patient developed synovitis of the elbow joint or suffered electrolytic reactions when titanium implants were used concurrently. CONCLUSION Although there is still a paucity of literature available on the subject and further studies are required, magnesium implants appear to be a feasible tool for fixation of peri-articular elbow fractures with promising results in our series.
Collapse
Affiliation(s)
- Christopher Fang
- Department of Orthopaedic Surgery, Khoo Teck Puat Hospital, National Healthcare Group, Singapore 768828, Singapore
| | - Antony Xavier Rex Premchand
- Department of Orthopaedic Surgery, Khoo Teck Puat Hospital, National Healthcare Group, Singapore 768828, Singapore
| | - Derek Howard Park
- Department of Orthopaedic Surgery, Khoo Teck Puat Hospital, National Healthcare Group, Singapore 768828, Singapore
| | - Dong Hao Toon
- Department of Orthopaedic Surgery, Khoo Teck Puat Hospital, National Healthcare Group, Singapore 768828, Singapore
| |
Collapse
|
3
|
Nasr Azadani M, Zahedi A, Bowoto OK, Oladapo BI. A review of current challenges and prospects of magnesium and its alloy for bone implant applications. Prog Biomater 2022; 11:1-26. [PMID: 35239157 DOI: 10.1007/s40204-022-00182-x] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 01/29/2022] [Indexed: 02/08/2023] Open
Abstract
Medical application materials must meet multiple requirements, and the designed implant must mimic the bone structure in shape and support the formation of bone tissue (osteogenesis). Magnesium (Mg) alloys, as a "smart" biodegradable material and as "the green engineering material in the twenty-first century", have become an outstanding bone implant material due to their natural degradability, smart biocompatibility, and desirable mechanical properties. Magnesium is recognised as the next generation of orthopaedic appliances and bioresorbable scaffolds. At the same time, improving the mechanical properties and corrosion resistance of magnesium alloys is an urgent challenge to promote the application of magnesium alloys. Nevertheless, the excessively quick deterioration rate generally results in premature mechanical integrity disintegration and local hydrogen build-up, resulting in restricted clinical bone restoration applicability. The condition of Mg bone implants is thoroughly examined in this study. The relevant approaches to boost the corrosion resistance, including purification, alloying treatment, surface coating, and Mg-based metal matrix composite, are comprehensively revealed. These characteristics are reviewed to assess the progress of contemporary Mg-based biocomposites and alloys for biomedical applications. The fabricating techniques for Mg bone implants also are thoroughly investigated. Notably, laser-based additive manufacturing fabricates customised forms and complicated porous structures based on its distinctive additive manufacturing conception. Because of its high laser energy density and strong controllability, it is capable of fast heating and cooling, allowing it to modify the microstructure and performance. This review paper aims to provide more insight on the present challenges and continued research on Mg bone implants, highlighting some of the most important characteristics, challenges, and strategies for improving Mg bone implants.
Collapse
Affiliation(s)
- Meysam Nasr Azadani
- School of Engineering and Sustainable Development, De Montfort University, Leicester, LE1 9BH, UK.
| | - Abolfazl Zahedi
- School of Engineering and Sustainable Development, De Montfort University, Leicester, LE1 9BH, UK
| | - Oluwole Kingsley Bowoto
- School of Engineering and Sustainable Development, De Montfort University, Leicester, LE1 9BH, UK
| | - Bankole Ibrahim Oladapo
- School of Engineering and Sustainable Development, De Montfort University, Leicester, LE1 9BH, UK
| |
Collapse
|
4
|
Magnesium-Based Alloys Used in Orthopedic Surgery. MATERIALS 2022; 15:ma15031148. [PMID: 35161092 PMCID: PMC8840615 DOI: 10.3390/ma15031148] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/18/2021] [Revised: 01/27/2022] [Accepted: 01/29/2022] [Indexed: 02/04/2023]
Abstract
Magnesium (Mg)-based alloys have become an important category of materials that is attracting more and more attention due to their high potential use as orthopedic temporary implants. These alloys are a viable alternative to nondegradable metals implants in orthopedics. In this paper, a detailed overview covering alloy development and manufacturing techniques is described. Further, important attributes for Mg-based alloys involved in orthopedic implants fabrication, physiological and toxicological effects of each alloying element, mechanical properties, osteogenesis, and angiogenesis of Mg are presented. A section detailing the main biocompatible Mg-based alloys, with examples of mechanical properties, degradation behavior, and cytotoxicity tests related to in vitro experiments, is also provided. Special attention is given to animal testing, and the clinical translation is also reviewed, focusing on the main clinical cases that were conducted under human use approval.
Collapse
|
5
|
Merlo JL, Katunar MR, Tano de la Hoz MF, Carrizo S, Salemme Alonso L, Otaz MA, Ballarre J, Ceré S. Short-Term In Vivo Response to Anodized Magnesium Alloy as a Biodegradable Material for Bone Fracture Fixation Devices. ACS APPLIED BIO MATERIALS 2021; 4:7123-7133. [DOI: 10.1021/acsabm.1c00735] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Affiliation(s)
- Julieta L. Merlo
- Applied Electrochemistry Division, Materials Science and Technology Research Institute (INTEMA), CONICET-University of Mar del Plata, Colon 10850, Mar del Plata 7600, Argentina
| | - María R. Katunar
- Applied Electrochemistry Division, Materials Science and Technology Research Institute (INTEMA), CONICET-University of Mar del Plata, Colon 10850, Mar del Plata 7600, Argentina
| | - María Florencia Tano de la Hoz
- Applied Electrochemistry Division, Materials Science and Technology Research Institute (INTEMA), CONICET-University of Mar del Plata, Colon 10850, Mar del Plata 7600, Argentina
| | - Sabrina Carrizo
- Applied Electrochemistry Division, Materials Science and Technology Research Institute (INTEMA), CONICET-University of Mar del Plata, Colon 10850, Mar del Plata 7600, Argentina
| | | | - María A. Otaz
- Otaz Veterinary, Gral. Mariano Necochea 826, Hurlingham 1686, Argentina
| | - Josefina Ballarre
- Applied Electrochemistry Division, Materials Science and Technology Research Institute (INTEMA), CONICET-University of Mar del Plata, Colon 10850, Mar del Plata 7600, Argentina
| | - Silvia Ceré
- Applied Electrochemistry Division, Materials Science and Technology Research Institute (INTEMA), CONICET-University of Mar del Plata, Colon 10850, Mar del Plata 7600, Argentina
| |
Collapse
|
6
|
Leigheb M, Veneziano M, Tortia R, Bosetti M, Cochis A, Rimondini L, Grassi FA. Osteosynthesis devices in absorbable Magnesium alloy in comparison to standard ones: a Systematic Review on effectiveness and safety. ACTA BIO-MEDICA : ATENEI PARMENSIS 2021; 92:e2021025. [PMID: 34313658 PMCID: PMC8420826 DOI: 10.23750/abm.v92is3.11757] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Accepted: 06/21/2021] [Indexed: 11/23/2022]
Abstract
BACKGROUND AND AIM OF THE WORK Magnesium (Mg) is a metal physiologically present in bone tissue and essential for bone health. Mg-based-alloys exhibit mechanical properties, namely density and strength, similar to human cortical bone. These features have been exploited for the development of osteosynthesis devices in biodegradable Mg-based-alloys. Accordingly, the aim of this study was to rank the effectiveness and safety of Mg-based alloys applied in bone surgery in comparison to other suitable metals, focusing in particular on Mg superior biocompatibility and biodegradability. METHODS a systematic-review of the literature was conducted including only primary research studies dealing with patients suffering from fractured or osteotomized bones fixed using Mg-based osteosynthesis-devices. RESULTS literature revision suggested Mg-alloys holding comparable properties and side effects in comparison with titanium (Ti) screws, thus showing similar efficacy and safety. In particular, the gas formation in the carpal bones was identified as the main side effect of the Mg-alloys, during the corrosion/degradation phase of Mg. CONCLUSIONS according to the considered literature, the main advantages exploiting Mg-alloys for bone implants are related to their biocompatibility, bio-absorbability/-degradability, the lack of surgical removal, osteoconductivity and antibacterial activity. On the opposite, the main limitation of Mg-alloys is due to the poor mechanical resistance of small devices for internal fixation of bone fragments that lack of sufficient strength to withstand high forces. Therefore, an important future prospect could rely in the development of innovative hybrid systems aimed at fixing high load-bearing fractures, as well as in regenerative-medicine by developing new Mg-based engineered scaffolds.
Collapse
Affiliation(s)
- Massimiliano Leigheb
- Orthopaedics and Traumatology, A.O.U. "Maggiore d.c."Universiy of Eastern Piedmont, Novara.
| | - Michela Veneziano
- Department of Orthopaedics and Traumatology, "Maggiore della Carità" Hospital, Novara, Italy.
| | - Rosalba Tortia
- Department of Health Sciences, Università del Piemonte Orientale (UPO), Novara, Italy.
| | - Michela Bosetti
- Department of "Scienze del Farmaco", Università del Piemonte Orientale (UPO), Novara, Italy.
| | - Andrea Cochis
- Department of Health Sciences, Center for Translational Research on Autoimmune and Allergic Diseases-CAAD, Università del Piemonte Orientale (UPO), Novara, Italy.
| | - Lia Rimondini
- Department of Health Sciences, Center for Translational Research on Autoimmune and Allergic Diseases-CAAD, Università del Piemonte Orientale (UPO), Novara, Italy.
| | - Federico Alberto Grassi
- Department of Orthopaedics and Traumatology, "Maggiore della Carità" Hospital, Novara, Italy; Department of Health Sciences, Università del Piemonte Orientale (UPO), Novara, Italy.
| |
Collapse
|
7
|
Prithivirajan S, Nyahale MB, Naik GM, Narendranath S, Prabhu A, Rekha PD. Bio-corrosion impacts on mechanical integrity of ZM21 Mg for orthopaedic implant application processed by equal channel angular pressing. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2021; 32:65. [PMID: 34117928 PMCID: PMC8197699 DOI: 10.1007/s10856-021-06535-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 05/28/2021] [Indexed: 06/12/2023]
Abstract
The mechanical integrity of rolled ZM21 Mg was improved by equal channel angular pressing (ECAP) to function as a potential biodegradable bone screw implant. Electron backscattered diffraction (EBSD) revealed deformed grains of 45 µm observed in rolled ZM21 Mg. They were transformed to equiaxed fine grains of 5.4 µm after 4th pass ECAP. The yield strength of rolled and ECAPed ZM21 Mg alloys were comparable. In contrast, 4th pass ZM21 Mg exhibited relatively higher elongation when compared to rolled sample. The mechanical properties of rolled and ECAPed ZM21 Mg were dependant on both grain refinement and crystallographic texture. The rolled and 4th pass ECAPed tensile samples exhibited nonlinear deterioration of mechanical properties when tested after 7, 14, 21 and 28 days immersion in Hank's solution. The evaluation signifies that regardless their processing condition, ZM21 Mg alloys are suitable for surgical areas that requires high mechanical strength. In addition, the 4th pass ECAP samples were viable to MG-63 cells proving themselves to be promising candidates for future in vivo studies.
Collapse
Affiliation(s)
- S Prithivirajan
- Corrosion Engineering Lab, Department of Mechanical Engineering, National Institute of Technology Karnataka, Surathkal, Srinivasanagar, Mangalore, Karnataka, India.
| | - Mayur Bapu Nyahale
- Corrosion Engineering Lab, Department of Mechanical Engineering, National Institute of Technology Karnataka, Surathkal, Srinivasanagar, Mangalore, Karnataka, India
| | - Gajanan M Naik
- Department of Mechanical Engineering, Mangalore Institute of Technology and Engineering, Moodbidri, Mangalore, Karnataka, India
| | - S Narendranath
- Corrosion Engineering Lab, Department of Mechanical Engineering, National Institute of Technology Karnataka, Surathkal, Srinivasanagar, Mangalore, Karnataka, India
| | - Ashwini Prabhu
- Yenepoya Research Centre, Yenepoya Medical College, Yenepoya (Deemed to be University), Deralakatte, Mangalore, Karnataka, India
| | - P D Rekha
- Yenepoya Research Centre, Yenepoya Medical College, Yenepoya (Deemed to be University), Deralakatte, Mangalore, Karnataka, India
| |
Collapse
|
8
|
Baldini M, Coppa V, Falcioni D, Senigagliesi E, Marinelli M, Gigante AP. Use of resorbable magnesium screws in children: systematic review of the literature and short-term follow-up from our series. J Child Orthop 2021; 15:194-203. [PMID: 34211595 PMCID: PMC8223084 DOI: 10.1302/1863-2548.15.210004] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Accepted: 04/06/2021] [Indexed: 02/03/2023] Open
Abstract
PURPOSE Biodegradable implants are of major interest in orthopaedics, especially in the skeletally immature population. Magnesium (Mg) implants are promising for selected surgical procedure in adults, but evidence is lacking. Thus, the aim of this study is to analyze the safety and efficacy of resorbable Mg screw in different orthopaedic procedures in skeletally immature patients. In addition, we present a systematic review of the current literature on the clinical use of Mg implants. METHODS From 2018 until the writing of this manuscript, consecutive orthopaedic surgical procedures involving the use of Mg screws performed at our centre in patients < 15 years of age were retrospectively reviewed. In addition, a systematic review of the literature was performed in the main databases. We included clinical studies conducted on humans, using Mg-alloy implants for orthopaedic procedures. RESULTS A total of 14 patients were included in this retrospective analysis. Mean age at surgery was 10.8 years (sd 2.4), mean follow-up was 13.8 months (sd 7.5). Healing was achieved in all the procedures, with no implant-related adverse reaction. No patients required any second surgical procedure. The systematic review evidenced 20 clinical studies, 19 of which conducted on an adult and one including paediatric patients. CONCLUSION Evidence on resorbable Mg implants is low but promising in adults and nearly absent in children. Our series included apophyseal avulsion, epiphyseal fractures, osteochondritis dissecans, displaced osteochondral fragment and tendon-to-bone fixation. Mg screws guaranteed stable fixation, without implant failure, with good clinical and radiological results and no adverse events. LEVEL OF EVIDENCE IV - Single cohort retrospective analysis with systematic review.
Collapse
Affiliation(s)
- Marco Baldini
- Clinical Orthopedics, Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, Ancona, Italy
| | - Valentino Coppa
- Clinical Orthopedics, Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, Ancona, Italy
| | - Danya Falcioni
- Clinic of Adult and Paediatric Orthopedic, Azienda Ospedal-iero-Universitaria, Ospedali Riuniti di Ancona, Ancona, Italy
| | - Elisa Senigagliesi
- Clinical Orthopedics, Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, Ancona, Italy
| | - Mario Marinelli
- Clinical Orthopedics, Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, Ancona, Italy
| | - Antonio Pompilio Gigante
- Clinical Orthopedics, Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, Ancona, Italy
- Clinic of Adult and Paediatric Orthopedic, Azienda Ospedal-iero-Universitaria, Ospedali Riuniti di Ancona, Ancona, Italy
| |
Collapse
|
9
|
Herber V, Okutan B, Antonoglou G, Sommer NG, Payer M. Bioresorbable Magnesium-Based Alloys as Novel Biomaterials in Oral Bone Regeneration: General Review and Clinical Perspectives. J Clin Med 2021; 10:jcm10091842. [PMID: 33922759 PMCID: PMC8123017 DOI: 10.3390/jcm10091842] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 04/15/2021] [Accepted: 04/19/2021] [Indexed: 02/07/2023] Open
Abstract
Bone preservation and primary regeneration is a daily challenge in the field of dental medicine. In recent years, bioresorbable metals based on magnesium (Mg) have been widely investigated due to their bone-like modulus of elasticity, their high biocompatibility, antimicrobial, and osteoconductive properties. Synthetic Mg-based biomaterials are promising candidates for bone regeneration in comparison with other currently available pure synthetic materials. Different alloys based on Mg were developed to fit clinical requirements. In parallel, advances in additive manufacturing offer the possibility to fabricate experimentally bioresorbable metallic porous scaffolds. This review describes the promising clinical results of resorbable Mg-based biomaterials for bone repair in osteosynthetic application and discusses the perspectives of use in oral bone regeneration.
Collapse
Affiliation(s)
- Valentin Herber
- Department of Dentistry and Oral Health, Division of Oral Surgery and Orthodontics, Medical University of Graz, Billrothgasse 4, 8010 Graz, Austria; (G.A.); (M.P.)
- Department of Orthopaedics and Traumatology, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz, Austria; (B.O.); (N.G.S.)
- Correspondence:
| | - Begüm Okutan
- Department of Orthopaedics and Traumatology, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz, Austria; (B.O.); (N.G.S.)
| | - Georgios Antonoglou
- Department of Dentistry and Oral Health, Division of Oral Surgery and Orthodontics, Medical University of Graz, Billrothgasse 4, 8010 Graz, Austria; (G.A.); (M.P.)
| | - Nicole G. Sommer
- Department of Orthopaedics and Traumatology, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz, Austria; (B.O.); (N.G.S.)
| | - Michael Payer
- Department of Dentistry and Oral Health, Division of Oral Surgery and Orthodontics, Medical University of Graz, Billrothgasse 4, 8010 Graz, Austria; (G.A.); (M.P.)
| |
Collapse
|
10
|
Holweg P, Herber V, Ornig M, Hohenberger G, Donohue N, Puchwein P, Leithner A, Seibert F. A lean bioabsorbable magnesium-zinc-calcium alloy ZX00 used for operative treatment of medial malleolus fractures: early clinical results of a prospective non-randomized first in man study. Bone Joint Res 2020; 9:477-483. [PMID: 32874554 PMCID: PMC7437522 DOI: 10.1302/2046-3758.98.bjr-2020-0017.r2] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Aims This study is a prospective, non-randomized trial for the treatment of fractures of the medial malleolus using lean, bioabsorbable, rare-earth element (REE)-free, magnesium (Mg)-based biodegradable screws in the adult skeleton. Methods A total of 20 patients with isolated, bimalleolar, or trimalleolar ankle fractures were recruited between July 2018 and October 2019. Fracture reduction was achieved through bioabsorbable Mg-based screws composed of pure Mg alloyed with zinc (Zn) and calcium (Ca) ( Mg-Zn0.45-Ca0.45, in wt.%; ZX00). Visual analogue scale (VAS) and the presence of complications (adverse events) during follow-up (12 weeks) were used to evaluate the clinical outcomes. The functional outcomes were analyzed through the range of motion (ROM) of the ankle joint and the American Orthopaedic Foot and Ankle Society (AOFAS) score. Fracture reduction and gas formation were assessed using several plane radiographs. Results The follow-up was performed after at least 12 weeks. The mean difference in ROM of the talocrural joint between the treated and the non-treated sites decreased from 39° (SD 12°) after two weeks to 8° (SD 11°) after 12 weeks (p ≤ 0.05). After 12 weeks, the mean AOFAS score was 92.5 points (SD 4.1). Blood analysis revealed that Mg and Ca were within a physiologically normal range. All ankle fractures were reduced and stabilized sufficiently by two Mg screws. A complete consolidation of all fractures was achieved. No loosening or breakage of screws was observed. Conclusion This first prospective clinical investigation of fracture reduction and fixation using lean, bioabsorbable, REE-free ZX00 screws showed excellent clinical and functional outcomes. Cite this article: Bone Joint Res 2020;9(8):477–483.
Collapse
Affiliation(s)
- Patrick Holweg
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Valentin Herber
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Martin Ornig
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Gloria Hohenberger
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Nicolas Donohue
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Paul Puchwein
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Andreas Leithner
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| | - Franz Seibert
- Department of Orthopaedics and Trauma, Medical University of Graz, Graz, Austria
| |
Collapse
|
11
|
Bioabsorbable magnesium screw versus conventional titanium screw fixation for medial malleolar fractures. J Orthop Traumatol 2020; 21:9. [PMID: 32451727 PMCID: PMC7248135 DOI: 10.1186/s10195-020-00547-7] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Accepted: 04/24/2020] [Indexed: 12/21/2022] Open
Abstract
Background It is still unknown whether bioabsorbable magnesium (Mg) screws provide an advantage over titanium screws in the treatment of medial malleolar (MM) fractures. The purpose of this retrospective study is to compare the clinical and radiological outcomes of MM fractures fixed with either bioabsorbable Mg screws or conventional titanium screws. Materials and methods A cohort of 48 patients with MM fractures who underwent compression screw fixation was retrospectively reviewed. Twenty-three patients (16 male, 7 female; mean age: 37.9 ± 17.7 years) were treated with bioabsorbable Mg screws, and 25 patients (14 male, 11 female; mean age: 45.0 ± 15.7 years) were treated with conventional titanium screw fixation. All patients were followed up for at least 1 year, with a mean time of 24.6 ± 10.5 months (12–53 months). The American Orthopedic Foot and Ankle Society (AOFAS) scale was used to evaluate the clinical results. The Kellgren–Lawrence (KL) osteoarthritis grading was used to evaluate posttraumatic osteoarthritis on final ankle radiographs. Fracture union, rate of implant removal, and complications were recorded. Comparative analysis of two independent groups was performed using the chi-squared test and the Mann–Whitney U-test. Results The two groups were comparable concerning demographic and clinical characteristics. Age (p = 0.146), sex (p = 0.252), side (p = 0.190), MM fracture type (p = 0.500), associated fractures (p = 0.470), and follow-up period (p = 0.903) were similar between the groups. At final follow-up examination, AOFAS score (p = 0.191) was similar between groups. Fracture union was achieved in all cases. Grade of posttraumatic osteoarthritis, according to KL, was equally distributed in both groups (p = 0.074). No deep infection or osteomyelitis was seen. Five patients in the titanium screw group underwent implant removal, due to pain in three of them and difficulty in wearing shoes in the other two (p = 0.031). Implant removal was performed after a mean of 14.2 ± 3.1 months (12–19 months). Conclusions Bioabsorbable Mg and titanium screws had similar therapeutic efficacy in MM fracture fixation regarding functional and radiological outcomes. However, the rate of implant removal was higher with titanium screws. Bioabsorbable Mg screws may be a favorable fixation option since secondary implant removal procedures can be prevented. Level of evidence Level IV, Retrospective case series.
Collapse
|
12
|
Könneker S, Krockenberger K, Pieh C, von Falck C, Brandewiede B, Vogt PM, Kirschner MH, Ziegler A. Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: protocol for the randomized controlled SCAMAG clinical trial. BMC Musculoskelet Disord 2019; 20:357. [PMID: 31387574 PMCID: PMC6685162 DOI: 10.1186/s12891-019-2723-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Accepted: 06/26/2019] [Indexed: 11/10/2022] Open
Abstract
Background Scaphoid fractures are the most common carpal fractures. They often need to be treated by surgery, where the use of a compression screw is the globally accepted gold standard. Surgeons may choose between different implant materials including titanium alloys, which remain in the body or are removed after healing. An alternative are biodegradable magnesium-based implants. Properties of magnesium alloys include high stability, osteoconductivity, potential reduction of infections and few artifacts in magnetic resonance imaging (MRI). The aim of this trial is to demonstrate non-inferiority of magnesium-based compression screws compared with titanium Herbert screws for scaphoid fractures. Methods The trial is designed as a multicenter, blinded observer, randomized controlled parallel two-group post market trial. Approximately 190 patients will be randomized (1:1) with stratification by center either to titanium or magnesium-based compression screws. Follow-up is 1 year per patient. Surgical procedures and aftercare will be performed according to the German treatment guideline for scaphoid fractures. The first primary endpoint is the patient-rated wrist evaluation (PRWE) score after 6 months. The second primary endpoint is a composite safety endpoint including bone union until 6 months, no adverse device effect (ADE) during surgery or wound healing and no serious ADE or reoperation within 1 year. The third primary endpoint is the difference in change MRI artifacts over time. Non-inferiority will be investigated for primary endpoints 1 (t-test confidence interval) and 2 (Wilson’s score interval) using both the full analysis set (FAS) and the per protocol population at the one-sided 2.5% test-level. Superiority of magnesium over titanium screws will be established using the FAS at the two-sided 5% test-level (Welch test) only if non-inferiority has been established for both primary endpoints. Secondary endpoints include quality of life. Discussion This study will inform care providers whether biodegradable magnesium-based implants are non-inferior to standard titanium Herbert screws for the treatment of scaphoid fractures in terms of wrist function and safety. Furthermore, superiority of magnesium-based implants may be demonstrated using MRI, which is used as surrogate endpoint for screw degradation. Trial registration DRKS, DRKS00013368. Registered Dec 04, 2017. Electronic supplementary material The online version of this article (10.1186/s12891-019-2723-9) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Sören Könneker
- Department of Plastic, Aesthetic, Hand and Reconstructive Surgery, Hanover Medical School (MHH), Carl-Neuberg-Straße 1, 30625, Hannover, Germany.
| | | | - Claudia Pieh
- Syntellix AG, Aegidientorplatz 2a, 30159, Hannover, Germany
| | - Christian von Falck
- Institute for Diagnostic and Interventional Radiology, Hanover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | | | - Peter M Vogt
- Department of Plastic, Aesthetic, Hand and Reconstructive Surgery, Hanover Medical School (MHH), Carl-Neuberg-Straße 1, 30625, Hannover, Germany
| | - Martin H Kirschner
- Syntellix AG, Aegidientorplatz 2a, 30159, Hannover, Germany.,Department for General, Trauma and Reconstructive Surgery, Ludwig-Maximilians University of Munich, Marchioninistraße 15, 81377, Munich, Germany
| | - Andreas Ziegler
- StatSol, Moenring 2, 23560, Lübeck, Germany. .,School of Mathematics, Statistics and Computer Science, University of KwaZulu-Natal, Pietermaritzburg, South Africa.
| |
Collapse
|
13
|
Acar B, Kose O, Unal M, Turan A, Kati YA, Guler F. Comparison of magnesium versus titanium screw fixation for biplane chevron medial malleolar osteotomy in the treatment of osteochondral lesions of the talus. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2019; 30:163-173. [PMID: 31375999 DOI: 10.1007/s00590-019-02524-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Accepted: 07/30/2019] [Indexed: 11/24/2022]
Abstract
PURPOSE This retrospective study aimed to compare the clinical and radiological outcomes of patients who underwent biplane chevron medial malleolar osteotomy (MMO) for osteochondral lesions of the talus (OLT), fixed with either magnesium (Mg) or titanium (Ti) screws. METHODS A total of 22 patients (12 male and 10 female) with a mean age of 40.6 ± 12.5 years (range 18-56 years) who underwent MMO for OLT treatment were included in this retrospective study. Of the 22 patients, MMO was fixed with bioabsorbable Mg screws (Alloy: MgYREZr) in 11 patients, and in the remaining 11 patients (one bilateral) MMO was fixed with Ti screws. All patients were followed up for at least 1 year with a mean of 20.7 ± 8.9 months (range 12-49 months). The American Orthopedic Foot and Ankle Society (AOFAS) scale and the visual analog scale (VAS) were used to evaluate the clinical results. Union of the osteotomy, postoperative displacement and all other complications were followed and analyzed. RESULTS An improvement in the AOFAS scale and VAS points were recorded in both groups with no statistically significant difference between the groups (p 0.079 and 0.107, respectively). Complete union of the osteotomy was obtained in all patients. One patient in the Ti group required implant removal due to pain and irritation. There were no other significant complications in either group. CONCLUSIONS The results of this study showed that bioabsorbable Mg compression screws have similar therapeutic efficacy to Ti screws in respect of functional and radiological outcomes in MMO fixation. Bioabsorbable Mg screw is an alternative fixation material which can be safely used for MMO in ankle surgery. LEVEL OF EVIDENCE Level IV, retrospective case series.
Collapse
Affiliation(s)
- Baver Acar
- Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, University of Health Sciences, Soğuksu mah. Kazım Karabekir cd., Muratpaşa, 07100, Antalya, Turkey
| | - Ozkan Kose
- Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, University of Health Sciences, Soğuksu mah. Kazım Karabekir cd., Muratpaşa, 07100, Antalya, Turkey.
| | - Melih Unal
- Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, University of Health Sciences, Soğuksu mah. Kazım Karabekir cd., Muratpaşa, 07100, Antalya, Turkey
| | - Adil Turan
- Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, University of Health Sciences, Soğuksu mah. Kazım Karabekir cd., Muratpaşa, 07100, Antalya, Turkey
| | - Yusuf Alper Kati
- Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, University of Health Sciences, Soğuksu mah. Kazım Karabekir cd., Muratpaşa, 07100, Antalya, Turkey
| | - Ferhat Guler
- Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, University of Health Sciences, Soğuksu mah. Kazım Karabekir cd., Muratpaşa, 07100, Antalya, Turkey
| |
Collapse
|
14
|
Dang LHN, Kim YK, Kim SY, Lim KJ, Bode K, Lee MH, Lee KB. Radiographic and histologic effects of bone morphogenetic protein-2/hydroxyapatite within bioabsorbable magnesium screws in a rabbit model. J Orthop Surg Res 2019; 14:117. [PMID: 31036024 PMCID: PMC6489201 DOI: 10.1186/s13018-019-1143-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Accepted: 04/04/2019] [Indexed: 01/06/2023] Open
Abstract
Background Hydrogen gas formed by magnesium (Mg) screw corrosion can accumulate around the implant and create bone cysts, long-term osteolysis lesions, and bone healing delay. Thus, several authors currently do not recommend Mg implants for clinical use. In contrast, bone morphogenetic proteins (BMP)-2 have a very strong osteoinductive activity. The purpose of this study was to evaluate the effect of rhBMP-2/hydroxyapatite (HA) inside specially designed Mg cannulated screws in a rabbit femur model for hydrogen gas formation avoidance. Methods Fifteen rabbits underwent randomly different cannulated Mg screw implantation in both distal femora; 30 femora were divided into three groups depending on the materials fill in the cannulated Mg screw: control group (Mg screw with no treatment), HA group (Mg screw with HA), and BMP-2/HA group (Mg screw with a composite BMP-2/HA). Plain radiography, micro-CT, and histological analysis were accomplished, and the ability to release BMP-2 of the screws was evaluated by immersion of both the screw with no treatment and screw with a composite BMP-2/HA into the SBF for up to 7 days. Results X-ray assessment found the gas shadow around the implant was slightly smaller in the BMP-2/HA group than the HA and control groups at 8 weeks. Micro-CT analysis demonstrated statistically significant higher new bone formation in the BMP-2/HA group than the other groups, respectively, which also correlated with a decreased gas volume. Histological analysis showed higher osteointegration between implants and host femurs in the BMP-2/HA group than the HA and control groups at 12 weeks. Conclusions This study indicates that the combination of BMP-2/HA within Mg screws enhances new bone formation and therefore has the potential to decrease the complications of hydrogen gas formation around these implants.
Collapse
Affiliation(s)
- Le Hoang Nam Dang
- Department of Orthopedic Surgery, Chonbuk National University Medical School, Research Institute of Clinical Medicine of Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Jeonju, South Korea
| | - Yu Kyoung Kim
- Department of Dental Biomaterials and Institute of Biodegradable Materials, Institute of Oral Bioscience and BK 21 Plus project, School of Dentistry, Chonbuk National University, Jeonju, South Korea
| | - Seo Young Kim
- Department of Dental Biomaterials and Institute of Biodegradable Materials, Institute of Oral Bioscience and BK 21 Plus project, School of Dentistry, Chonbuk National University, Jeonju, South Korea
| | - Kuk Jin Lim
- Department of Orthopedic Surgery, Chonbuk National University Medical School, Research Institute of Clinical Medicine of Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Jeonju, South Korea
| | - Ken Bode
- Department of Orthopedic Surgery, Chonbuk National University Medical School, Research Institute of Clinical Medicine of Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Jeonju, South Korea
| | - Min Ho Lee
- Department of Dental Biomaterials and Institute of Biodegradable Materials, Institute of Oral Bioscience and BK 21 Plus project, School of Dentistry, Chonbuk National University, Jeonju, South Korea
| | - Kwang Bok Lee
- Department of Orthopedic Surgery, Chonbuk National University Medical School, Research Institute of Clinical Medicine of Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Jeonju, South Korea.
| |
Collapse
|