1
|
Takahashi K, Ozawa E, Shimakura A, Mori T, Miyaaki H, Nakao K. Recent Advances in Endoscopic Ultrasound for Gallbladder Disease Diagnosis. Diagnostics (Basel) 2024; 14:374. [PMID: 38396413 PMCID: PMC10887964 DOI: 10.3390/diagnostics14040374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 02/01/2024] [Accepted: 02/05/2024] [Indexed: 02/25/2024] Open
Abstract
Gallbladder (GB) disease is classified into two broad categories: GB wall-thickening and protuberant lesions, which include various lesions, such as adenomyomatosis, cholecystitis, GB polyps, and GB carcinoma. This review summarizes recent advances in the differential diagnosis of GB lesions, focusing primarily on endoscopic ultrasound (EUS) and related technologies. Fundamental B-mode EUS and contrast-enhanced harmonic EUS (CH-EUS) have been reported to be useful for the diagnosis of GB diseases because they can evaluate the thickening of the GB wall and protuberant lesions in detail. We also outline the current status of EUS-guided fine-needle aspiration (EUS-FNA) for GB lesions, as there have been scattered reports on EUS-FNA in recent years. Furthermore, artificial intelligence (AI) technologies, ranging from machine learning to deep learning, have become popular in healthcare for disease diagnosis, drug discovery, drug development, and patient risk identification. In this review, we outline the current status of AI in the diagnosis of GB.
Collapse
Affiliation(s)
- Kosuke Takahashi
- Department of Gastroenterology and Hepatology, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki 852-8501, Japan; (E.O.); (T.M.); (H.M.); (K.N.)
| | | | | | | | | | | |
Collapse
|
2
|
Hashimoto S, Ohno E, Yamamoto S, Nakaoka K, Hirooka Y. The role of contrast-enhanced endoscopic ultrasound for biliary diseases. J Med Ultrason (2001) 2023:10.1007/s10396-023-01385-w. [PMID: 37991545 DOI: 10.1007/s10396-023-01385-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 09/29/2023] [Indexed: 11/23/2023]
Abstract
Contrast-enhanced endoscopic ultrasound (CE-EUS) has emerged as a promising diagnostic modality for assessing biliary diseases. CE-EUS is a noninvasive imaging technique that utilizes contrast agents to enhance the visualization of blood vessels and perfusion within target tissues. In the context of biliary diseases, CE-EUS allows for improved characterization of biliary lesions, aiding in differential diagnosis and treatment planning. This review highlights several key findings regarding the usefulness of CE-EUS in biliary disease assessment and therapeutic procedures.
Collapse
Affiliation(s)
- Senju Hashimoto
- Department of Gastroenterology and Hepatology, School of Medicine, Fujita Health University Bantane Hospital, 3-6-10 Otoubashi, Nakagawa-ku, Nagoya, Aichi, 454-8509, Japan.
| | - Eizaburo Ohno
- Department of Gastroenterology and Hepatology, School of Medicine, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan
| | - Satoshi Yamamoto
- Department of Gastroenterology and Hepatology, School of Medicine, Fujita Health University Bantane Hospital, 3-6-10 Otoubashi, Nakagawa-ku, Nagoya, Aichi, 454-8509, Japan
| | - Kazunori Nakaoka
- Department of Gastroenterology and Hepatology, School of Medicine, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan
| | - Yoshiki Hirooka
- Department of Gastroenterology and Hepatology, School of Medicine, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan
| |
Collapse
|
3
|
Yamashita Y, Ashida R, Tamura T, Shimokawa T, Yamazaki H, Kawaji Y, Tamura T, Hatamaru K, Itonaga M, Kitano M. Novel Technique of Endoscopic Ultrasonography for the Differential Diagnosis of Gallbladder Lesions and Intraductal Papillary Mucinous Neoplasms: A Single-Center Prospective Study. Diagnostics (Basel) 2023; 13:2132. [PMID: 37443527 DOI: 10.3390/diagnostics13132132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 06/17/2023] [Accepted: 06/19/2023] [Indexed: 07/15/2023] Open
Abstract
Detective flow imaging endoscopic ultrasonography (DFI-EUS) is an innovative imaging modality that was developed to detect fine vessels and low-velocity blood flow without contrast agents. We evaluate its utility for the differential diagnosis of gallbladder lesions and intraductal papillary mucinous neoplasms (IPMNs). We enrolled patients who underwent DFI-EUS, e-FLOW EUS, and contrast-enhanced EUS for gallbladder lesions or IPMNs. The detection of vessels using DFI-EUS and e-FLOW EUS was compared with that via contrast-enhanced EUS and pathological findings. The vessel pattern was also categorized as regular or irregular. Of the 33 lesions included, there were final diagnoses of 13 IPMNs and 20 gallbladder lesions. DFI-EUS was significantly superior to e-FLOW EUS for discriminating between mural nodules and mucous clots and between solid gallbladder lesions and sludge using the presence or absence of vessel detection in lesions (p = 0.005). An irregular vessel pattern with DFI-EUS was a significant predictor of malignant gallbladder lesions (p = 0.002). DFI-EUS is more sensitive than e-FLOW-EUS for vessel detection and the differential diagnosis of gallbladder lesions and IPMNs. Vessel evaluation using DFI-EUS may be a useful and simple method for differentiating between mural nodules and mucous clots in IPMN, between solid gallbladder lesions and sludge, and between malignant and benign gallbladder lesions.
Collapse
Affiliation(s)
- Yasunobu Yamashita
- Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama 641-0012, Japan
| | - Reiko Ashida
- Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama 641-0012, Japan
| | - Takaaki Tamura
- Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama 641-0012, Japan
- Department of Human Pathology, Wakayama Medical University, 811-1, Kimiidera, Wakayama 641-0012, Japan
| | - Toshio Shimokawa
- Clinical Study Support Center, Wakayama Medical University Hospital, 811-1, Kimiidera, Wakayama 641-0012, Japan
| | - Hirofumi Yamazaki
- Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama 641-0012, Japan
| | - Yuki Kawaji
- Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama 641-0012, Japan
| | - Takashi Tamura
- Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama 641-0012, Japan
| | - Keiichi Hatamaru
- Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama 641-0012, Japan
| | - Masahiro Itonaga
- Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama 641-0012, Japan
| | - Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama 641-0012, Japan
| |
Collapse
|
4
|
Li Q, Zhang J, Cai Z, Jia P, Wang X, Geng X, Zhang Y, Lei D, Li J, Yang W, Yang R, Zhang X, Yang C, Yao C, Hao Q, Liu Y, Guo Z, Si S, Geng Z, Zhang D. A Bayesian network prediction model for gallbladder polyps with malignant potential based on preoperative ultrasound. Surg Endosc 2023; 37:518-527. [PMID: 36002683 DOI: 10.1007/s00464-022-09532-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 07/31/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND It is important to identify gallbladder polyps (GPs) with malignant potential and avoid unnecessary cholecystectomy by constructing prediction model. The aim of the study is to develop a Bayesian network (BN) prediction model for GPs with malignant potential in a long diameter of 8-15 mm based on preoperative ultrasound. METHODS The independent risk factors for GPs with malignant potential were screened by χ2 test and Logistic regression model. Prediction model was established and validated using data from 1296 patients with GPs who underwent cholecystectomy from January 2015 to December 2019 at 11 tertiary hospitals in China. A BN model was established based on the independent risk variables. RESULTS Independent risk factors for GPs with malignant potential included age, number of polyps, polyp size (long diameter), polyp size (short diameter), and fundus. The BN prediction model identified relationships between polyp size (long diameter) and three other variables [polyp size (short diameter), fundus and number of polyps]. Each variable was assigned scores under different status and the probabilities of GPs with malignant potential were classified as [0-0.2), [0.2-0.5), [0.5-0.8) and [0.8-1] according to the total points of [- 337, - 234], [- 197, - 145], [- 123, - 108], and [- 62,500], respectively. The AUC was 77.38% and 75.13%, and the model accuracy was 75.58% and 80.47% for the BN model in the training set and testing set, respectively. CONCLUSION A BN prediction model was accurate and practical for predicting GPs with malignant potential patients in a long diameter of 8-15 mm undergoing cholecystectomy based on preoperative ultrasound.
Collapse
Affiliation(s)
- Qi Li
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi, China
| | - Jingwei Zhang
- Department of Industrial Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, Shaanxi, China
| | - Zhiqiang Cai
- Department of Industrial Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, Shaanxi, China
| | - Pengbo Jia
- Department of Hepatobiliary Surgery, The First People's Hospital of Xianyang City, Xianyang, 712000, Shaanxi, China
| | - Xintuan Wang
- Department of Hepatobiliary Surgery, The First People's Hospital of Xianyang City, Xianyang, 712000, Shaanxi, China
| | - Xilin Geng
- Department of Hepatobiliary Surgery, Shaanxi Provincial People's Hospital, Xi'an, 710068, Shaanxi, China
| | - Yu Zhang
- Department of Hepatobiliary Surgery, Shaanxi Provincial People's Hospital, Xi'an, 710068, Shaanxi, China
| | - Da Lei
- Department of Hepatobiliary Surgery, Central Hospital of Baoji City, Baoji, 721000, Shaanxi, China
| | - Junhui Li
- Department of General Surgery, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, Shaanxi, China
| | - Wenbin Yang
- Department of General Surgery, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, Shaanxi, China
| | - Rui Yang
- Department of Hepatobiliary Surgery, Central Hospital of Hanzhong City, Hanzhong, 723000, Shaanxi, China
| | - Xiaodi Zhang
- Department of General Surgery, No. 215 Hospital of Shaanxi Nuclear Industry, Xianyang, 712000, Shaanxi, China
| | - Chenglin Yang
- Department of General Surgery, Central Hospital of Ankang City, Ankang, 725000, Shaanxi, China
| | - Chunhe Yao
- Department of General Surgery, Xianyang Hospital of Yan'an University, Xianyang, 712000, Shaanxi, China
| | - Qiwei Hao
- Department of Hepatobiliary Surgery, The Second Hospital of Yulin City, Yulin, 719000, Shaanxi, China
| | - Yimin Liu
- Department of Hepatobiliary Surgery, People's Hospital of Baoji City, Baoji, 721000, Shaanxi, China
| | - Zhihua Guo
- Department of Hepatobiliary Surgery, People's Hospital of Baoji City, Baoji, 721000, Shaanxi, China
| | - Shubin Si
- Department of Industrial Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, Shaanxi, China
| | - Zhimin Geng
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi, China.
| | - Dong Zhang
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi, China.
| |
Collapse
|
5
|
Zhu L, Han P, Jiang B, Li N, Jiao Z, Zhu Y, Tang W, Fei X. Value of Conventional Ultrasound-based Scoring System in Distinguishing Adenomatous Polyps From Cholesterol Polyps. J Clin Gastroenterol 2022; 56:895-901. [PMID: 34907919 DOI: 10.1097/mcg.0000000000001639] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 10/18/2021] [Indexed: 12/10/2022]
Abstract
BACKGROUND AND AIM Ultrasound has increased the detection of gallbladder polyps, but it has limitations in evaluating the nature of gallbladder polyps, especially the maximum size of 1.0 to 1.5 cm. We assessed the value of ultrasound scoring system based on independent predictive parameters in distinguishing adenomatous polyps from cholesterol polyps with the maximum size of 1.0 to 1.5 cm. MATERIALS AND METHODS We enrolled 163 patients with gallbladder polyps (1.0 to 1.5 cm) who underwent ultrasonography and cholecystectomy. Ultrasound image characteristics were compared between cholesterol polyps and adenomatous polyps in the training cohort from April 2018 to January 2020. An ultrasound scoring system was constructed in the training cohort, and its diagnostic performance was evaluated in the validation cohort from February 2020 to February 2021. RESULTS Maximum size, height/width ratio, stone or sludge, vascularity, and hyperechoic spot were significantly different between cholesterol polyps and adenomatous polyps in the training cohort ( P <0.05). The independent predictive parameters for adenomatous polyps were lower height/width ratio, presence of vascularity and absence of hyperechoic spot. The total score was as follows: (height/width ratio, <0.9=4, ≥0.9=0) + (vascularity, present=3, absent=0) + (hyperechoic spot, absent=2, present=0). The sensitivity, specificity and accuracy of ultrasound scoring system ≥5 for diagnosis of adenomatous polyps in the validation cohort were 73.33%, 80.49%, and 78.57%, respectively. CONCLUSIONS The ultrasound scoring system aids in distinguishing adenomatous polyps from cholesterol polyps, and effectively decreasing unnecessary cholecystectomy.
Collapse
Affiliation(s)
| | | | | | - Nan Li
- Departments of Ultrasound
| | | | | | - Wenbo Tang
- Hepatobiliary Surgery, the First Medical Center, Chinese PLA General Hospital, Beijing, China
| | | |
Collapse
|
6
|
Zhu L, Han P, Jiang B, Li N, Fei X. [Differential diagnosis of gallbladder polypoid lesions by micro-flow imaging]. Nan Fang Yi Ke Da Xue Xue Bao 2022; 42:922-928. [PMID: 35790444 DOI: 10.12122/j.issn.1673-4254.2022.06.17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
OBJECTIVE To explore the value of micro-flow imaging (MFI) in evaluating blood flow characteristics and differential diagnosis of gallbladder polypoid lesions. METHODS We retrospectively analyzed the clinical data and ultrasound images of 73 patients with gallbladder polypoid lesions, including 24 patients with pathologically confirmed neoplastic polyps (n=24) and 49 with non-neoplastic polyps (n=49). All the patients underwent conventional ultrasound, MFI and contrast enhanced ultrasound (CEUS) before cholecystectomy. The blood flow characteristics of the lesions in color Doppler flow imaging (CDFI) and MFI were compared, and the consistency of the findings by these two modalities with those of CEUS were evaluated by weighted Kappa consistency test. The diagnostic performance of MFI for gallbladder polypoid lesions was assessed. RESULTS There were significant differences between MFI and CDFI in the evaluation of blood flow characteristics of gallbladder polypoid lesions (χ2=37.684, P < 0.001). MFI showed better performance than CDFI in displaying the blood flow characteristics of the polyps. The consistency in the findings was 0.118 between CDFI and CEUS and 0.816 between MFI and CEUS. The sensitivity, specificity and accuracy of MFI in distinguishing neoplastic polyps from non-neoplastic polyps were 75.00%, 93.88% and 87.67%, respectively. CONCLUSION MFI has a good consistency with CEUS in displaying the blood flow characteristics of gallbladder polypoid lesions and can accurately distinguish neoplastic polyps from non-neoplastic polyps, thus providing new ultrasound diagnostic evidence to support clinical decisions on optimal treatments of gallbladder polypoid lesions.
Collapse
Affiliation(s)
- L Zhu
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - P Han
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - B Jiang
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - N Li
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - X Fei
- Department of Ultrasound, First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| |
Collapse
|
7
|
Wang X, Zhu JA, Liu YJ, Liu YQ, Che DD, Niu SH, Gao S, Chen DB. Conventional Ultrasound Combined With Contrast-Enhanced Ultrasound in Differential Diagnosis of Gallbladder Cholesterol and Adenomatous Polyps (1-2 cm). J Ultrasound Med 2022; 41:617-626. [PMID: 33938029 DOI: 10.1002/jum.15740] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 04/15/2021] [Accepted: 04/17/2021] [Indexed: 05/23/2023]
Abstract
OBJECTIVES This study aimed to determine ultrasonic image characteristics that enable differentiation between cholesterol and adenomatous polyps and to assess the diagnostic efficacy of combining conventional ultrasound (CUS) with contrast-enhanced ultrasound (CEUS). METHODS Eighty-nine patients with gallbladder polyps of 1-2 cm in diameter were enrolled and examined by CUS and CEUS before cholecystectomy. The appearances on CUS and CEUS were recorded and analyzed. The receiver operating characteristic (ROC) curve was used to calculate the optimal size threshold for distinguishing cholesterol from adenomatous polyps. A logistic regression analysis was performed to identify diagnostic variables. ROC analysis was performed to evaluate the diagnostic efficacy of the size, the independent variables, and the combined factors. RESULTS There were differences in size, number, vascularity on CUS and intralesional vascular shape, wash-out, and area under the curve on CEUS between the two groups (P < .05). ROC analysis indicated that a maximum diameter of 1.45 cm was the optimal threshold for the prediction of adenomatous polyps. The logistic regression analysis proved that the single polyp, presence of vascularity, and intralesional linear vessels were associated with adenomatous polyps (P < .05). ROC analysis showed that the area under the ROC curve, sensitivity, and specificity for the combination of the three independent variables were 0.858, 87.3%, and 67.6%. The number combined with intralesional vascular shape had the highest diagnostic sensitivity of 91.2%. CONCLUSIONS The combination of CUS and CEUS demonstrated great significance in the differential diagnosis of cholesterol and adenomatous polyps.
Collapse
Affiliation(s)
- Xue Wang
- Department of Ultrasound, Peking University People's Hospital, Beijing, China
| | - Jia-An Zhu
- Department of Ultrasound, Peking University People's Hospital, Beijing, China
| | - Yue-Jie Liu
- Department of Ultrasound, Peking University People's Hospital, Beijing, China
| | - Yi-Qun Liu
- Department of Ultrasound, Peking University People's Hospital, Beijing, China
| | - Dong-Dong Che
- Department of Ultrasound, Peking University People's Hospital, Beijing, China
| | - Si-Hua Niu
- Department of Ultrasound, Peking University People's Hospital, Beijing, China
| | - Shuang Gao
- Department of Ultrasound, Peking University People's Hospital, Beijing, China
| | - Ding-Bao Chen
- Department of Pathology, Peking University People's Hospital, Beijing, China
| |
Collapse
|
8
|
Jang SI, Kim YJ, Kim EJ, Kang H, Shon SJ, Seol YJ, Lee DK, Kim KG, Cho JH. Diagnostic performance of endoscopic ultrasound-artificial intelligence using deep learning analysis of gallbladder polypoid lesions. J Gastroenterol Hepatol 2021; 36:3548-3555. [PMID: 34431545 DOI: 10.1111/jgh.15673] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 08/14/2021] [Accepted: 08/20/2021] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIM Endoscopic ultrasound (EUS) is the most accurate diagnostic modality for polypoid lesions of the gallbladder (GB), but is limited by subjective interpretation. Deep learning-based artificial intelligence (AI) algorithms are under development. We evaluated the diagnostic performance of AI in differentiating polypoid lesions using EUS images. METHODS The diagnostic performance of the EUS-AI system with ResNet50 architecture was evaluated via three processes: training, internal validation, and testing using an AI development cohort of 1039 EUS images (836 GB polyps and 203 gallstones). The diagnostic performance was verified using an external validation cohort of 83 patients and compared with the performance of EUS endoscopists. RESULTS In the AI development cohort, we developed an EUS-AI algorithm and evaluated the diagnostic performance of the EUS-AI including sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. For the differential diagnosis of neoplastic and non-neoplastic GB polyps, these values for EUS-AI were 57.9%, 96.5%, 77.8%, 91.6%, and 89.8%, respectively. In the external validation cohort, we compared diagnostic performances between EUS-AI and endoscopists. For the differential diagnosis of neoplastic and non-neoplastic GB polyps, the sensitivity and specificity were 33.3% and 96.1% for EUS-AI; they were 74.2% and 44.9%, respectively, for the endoscopists. Besides, the accuracy of the EUS-AI was between the accuracies of mid-level (66.7%) and expert EUS endoscopists (77.5%). CONCLUSIONS This newly developed EUS-AI system showed favorable performance for the diagnosis of neoplastic GB polyps, with a performance comparable to that of EUS endoscopists.
Collapse
Affiliation(s)
- Sung Ill Jang
- Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Young Jae Kim
- Department of Biomedical Engineering, Gachon University College of Health Science, Incheon, South Korea
| | - Eui Joo Kim
- Department of Internal Medicine, Gil Medical Center, Gachon University College of Medicine, Incheon, South Korea
| | - Huapyong Kang
- Department of Internal Medicine, Gil Medical Center, Gachon University College of Medicine, Incheon, South Korea
| | - Seung Jin Shon
- Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Yu Jin Seol
- Department of Biomedical Engineering, Gachon University College of Health Science, Incheon, South Korea
| | - Dong Ki Lee
- Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Kwang Gi Kim
- Department of Biomedical Engineering, Gachon University College of Health Science, Incheon, South Korea
| | - Jae Hee Cho
- Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| |
Collapse
|
9
|
Fei X, Li N, Zhu L, Han P, Jiang B, Tang W, Sang M, Zhang X, Luo Y. Value of high frame rate contrast-enhanced ultrasound in distinguishing gallbladder adenoma from cholesterol polyp lesion. Eur Radiol 2021; 31:6717-6725. [PMID: 33569621 DOI: 10.1007/s00330-021-07730-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 12/10/2020] [Accepted: 01/28/2021] [Indexed: 02/05/2023]
Abstract
OBJECTIVES To compare the diagnostic value of high frame rate contrast-enhanced ultrasound (H-CEUS) in distinguishing gallbladder adenomas from cholesterol polyp lesions with that of CEUS. METHODS This study enrolled 94 patients with gallbladder polyp lesions (GPLs) who underwent laparoscopic cholecystectomy. CEUS and H-CEUS were performed before surgery. The perfusion features of GPLs and the final diagnosis as determined by both technologies were compared. RESULTS There were differences in vascular types between gallbladder adenomas and cholesterol polyp lesions observed on H-CEUS (p < 0.05), while there were no differences in vascular types between gallbladder adenomas and cholesterol polyp lesions observed on CEUS (p > 0.05). In the cholesterol polyp lesion group, there were no differences in vascular types between CEUS and H-CEUS (p > 0.05), while the vascular types were different between CEUS and H-CEUS in the gallbladder adenoma group (p < 0.05). The diagnostic value of H-CEUS in distinguishing gallbladder adenomas from cholesterol polyp lesions was better than that of CEUS. CONCLUSIONS H-CEUS improved the time resolution by increasing the frame rate, which helped to accurately reflect the difference in the microcirculation of GPLs and improved the ability of a differential diagnosis between cholesterol polyp lesions and adenomas. H-CUES may provide an effective means of imaging for patients with GPLs regarding the choice of treatment options. KEY POINTS • High frame rate CEUS improves the time resolution of CEUS by increasing the frame rate. • High frame rate CEUS is helpful to accurately evaluate the microvascular morphology of a gallbladder polyp lesion in the arterial phase. • High frame rate CEUS helps patients with gallbladder polyp lesions to choose the appropriate treatment means.
Collapse
Affiliation(s)
- Xiang Fei
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, No. 28, Fuxing Road, Haidian District, Beijing, 100853, China
| | - Nan Li
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, No. 28, Fuxing Road, Haidian District, Beijing, 100853, China
| | - Lianhua Zhu
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, No. 28, Fuxing Road, Haidian District, Beijing, 100853, China
| | - Peng Han
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, No. 28, Fuxing Road, Haidian District, Beijing, 100853, China
| | - Bo Jiang
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, No. 28, Fuxing Road, Haidian District, Beijing, 100853, China
| | - Wenbo Tang
- Department of Hepatobiliary Surgery, the First Medical Center, Chinese PLA General Hospital, No. 28, Fuxing Road, Haidian District, Beijing, 100853, China
| | - Maodong Sang
- Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Nanshan District, Shenzhen, 518055, China
| | - Xirui Zhang
- Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Nanshan District, Shenzhen, 518055, China
| | - Yukun Luo
- Department of Ultrasound, the First Medical Center, Chinese PLA General Hospital, No. 28, Fuxing Road, Haidian District, Beijing, 100853, China.
| |
Collapse
|
10
|
Hijioka S, Nagashio Y, Ohba A, Maruki Y, Okusaka T. The Role of EUS and EUS-FNA in Differentiating Benign and Malignant Gallbladder Lesions. Diagnostics (Basel) 2021; 11:diagnostics11091586. [PMID: 34573929 PMCID: PMC8467412 DOI: 10.3390/diagnostics11091586] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2021] [Revised: 08/25/2021] [Accepted: 08/26/2021] [Indexed: 12/17/2022] Open
Abstract
Endoscopic ultrasonography (EUS) has greater spatial resolution than other diagnostic imaging modalities. In addition, if gallbladder lesions are found and gallbladder cancer is suspected, EUS is an indispensable modality, enabling detailed tests for invasion depth evaluation using the Doppler mode and ultrasound agents. Furthermore, for gallbladder lesions, EUS fine-needle aspiration (EUS-FNA) can be used to differentiate benign and malignant forms of conditions, such as xanthogranulomatous cholecystitis, and collect evidence before chemotherapy. EUS-FNA is also useful for highly precise and specific diagnoses. However, the prevention of bile leakage, an accidental symptom, is highly important. Advancements in next-generation sequencing (NGS) technologies facilitate the application of multiple parallel sequencing to EUS-FNA samples. Several biomarkers are expected to stratify treatment for gallbladder cancer; however, NGS can unveil potential predictive genomic biomarkers for the treatment response. It is believed that NGS may be feasible with samples obtained using EUS-FNA, further increasing the demand for EUS-FNA.
Collapse
Affiliation(s)
- Susumu Hijioka
- Correspondence: ; Tel.: +81-52-762-6111; Fax: +81-52-763-5233
| | | | | | | | | |
Collapse
|
11
|
Jang SI, Cho JH, Lee DK. [Recent Updates on Diagnosis, Treatment, and Follow-up of Gallbladder Polyps]. Korean J Gastroenterol 2021; 76:102-107. [PMID: 32969359 DOI: 10.4166/kjg.2020.76.3.102] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 08/15/2020] [Accepted: 08/15/2020] [Indexed: 01/28/2023]
Abstract
A gallbladder (GB) polyp is an elevation of the GB mucosa that protrudes into the GB lumen. GB polyps have an estimated prevalence of 0.3-9.5% and can be divided into neoplastic (true) polyps and nonneoplastic polyps (pseudopolyps). Pseudopolyps are most commonly cholesterol polyps but also include focal adenomyomatosis and inflammatory polyps with no malignant potential. Neoplastic polyps, however, can be benign or malignant. Benign polyps are most commonly adenomas, while malignant polyps are usually adenocarcinoma. Transabdominal ultrasonography is the main radiological modality used for diagnosing and surveilling GB polyps. On the other hand, because it is difficult to diagnose GB polyps before surgery, alternative imaging modalities, such as endoscopic ultrasound, are being further evaluated. The current guidelines recommend cholecystectomy for GB polyps ≥ 10 mm in size as well as suboptimal sized GB polyps (6-9 mm) with other risk factors, including age >50, sessile, and symptoms. The quality of the evidence behind this practice is relatively low. Therefore, this review identifies the current gaps in the available evidence and guidelines and introduces methods that can help make decisions regarding patients who require a cholecystectomy or follow-up.
Collapse
Affiliation(s)
- Sung Ill Jang
- Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Jae Hee Cho
- Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Dong Ki Lee
- Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
12
|
Kitano M, Yamashita Y, Kamata K, Ang TL, Imazu H, Ohno E, Hirooka Y, Fusaroli P, Seo DW, Napoléon B, Teoh AYB, Kim TH, Dietrich CF, Wang HP, Kudo M. The Asian Federation of Societies for Ultrasound in Medicine and Biology (AFSUMB) Guidelines for Contrast-Enhanced Endoscopic Ultrasound. Ultrasound Med Biol 2021; 47:1433-1447. [PMID: 33653627 DOI: 10.1016/j.ultrasmedbio.2021.01.030] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 01/25/2021] [Accepted: 01/28/2021] [Indexed: 06/12/2023]
Abstract
The Asian Federation of Societies for Ultrasound in Medicine and Biology aimed to provide information on techniques and indications for contrast-enhanced harmonic endoscopic ultrasound (CH-EUS), and to create statements including the level of recommendation. These statements are based on current scientific evidence reviewed by a Consensus Panel of 15 internationally renowned experts. The reliability of clinical questions was measured by agreement rates after voting. Six statements were made on techniques, including suitable contrast agents for CH-EUS, differences between contrast agents, setting of mechanical index, dual imaging and duration and phases for observation. Thirteen statements were made on indications, including pancreatic solid masses, pancreatic cancer staging, pancreatic cystic lesions and mural nodules, detection of subtle pancreatic lesions, gallbladder sludge and polyps, hepatic lesions, lymph nodes, subepithelial lesions, visceral vascular diseases, guidance of fine needle aspiration and evaluation for local therapy. These international expert consensus guidelines will assist endosonographers in conducting CH-EUS according to evidence-based information.
Collapse
Affiliation(s)
- Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan.
| | - Yasunobu Yamashita
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Ken Kamata
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka-Sayama, Japan
| | - Tiing Leong Ang
- Department of Gastroenterology and Hepatology, Changi General Hospital, Singapore
| | - Hiroo Imazu
- Division of Gastroenterology and Hepatology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Eizaburo Ohno
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School, Nagoya, Japan
| | - Yoshiki Hirooka
- Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University, Aichi, Japan
| | - Pietro Fusaroli
- Gastroenterology Unit, Department of Medical and Surgical Sciences, University of Bologna/Hospital of Imola, Imola, Italy
| | - Dong-Wan Seo
- Department of Gastroenterology, Asan Medical Centre, Seoul, Korea
| | - Bertrand Napoléon
- Department of Gastroenterology, Jean Mermoz Private Hospital, Ramsay Generale de Sante, Lyon, France
| | - Anthony Yuen Bun Teoh
- Department of Surgery, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong, China
| | - Tae Hyeon Kim
- Department of Internal Medicine, Wonkwang University College of Medicine, Iksan, South Korea
| | - Christoph F Dietrich
- Department of Internal Medicine (DAIM), Hirslanden Kliniken Beau Site, Salem und Permanence Bern, Switzerland
| | - Hsiu-Po Wang
- Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Masatoshi Kudo
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka-Sayama, Japan
| |
Collapse
|
13
|
Gautam A, Pandey A, Masood S, Chauhan S, Choudhary D, Kumar S, Madhawan S, Jha S, Saini V. Incidental Gallbladder Carcinoma in Gallbladder Polyps: Challenges of Gallbladder Malignancy for an Endemic Population. Malays J Med Sci 2021; 28:27-34. [PMID: 33679217 PMCID: PMC7909354 DOI: 10.21315/mjms2021.28.1.4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2020] [Accepted: 11/05/2020] [Indexed: 11/17/2022] Open
Abstract
Background Gallbladder polyps are considered pre-malignant lesions of gallbladder carcinoma. This study aims to highlight the role of early cholecystectomy in the management of gallbladder polyps in an endemic population. Methods A retrospective analysis of 2,076 lap cholecystectomy procedures performed at the Department of Surgical Gastroenterology at a tertiary referral centre in Northern India was conducted and incidental malignancy in gallbladder polyps analysed. The 8th edition of the American Joint Committee on Cancer for tumour-node-metastasis (TNM) staging of gallbladder carcinoma was used. Results Of 54 patients with gallbladder polyps, 53 had benign histology and one had malignant cells in the lamina propria suggestive of T1a adenocarcinoma. The patient with the malignant polyp was older (57 years old) than the patients in the non-cancer group, which had a mean age of 45 (P = 0.039). The size of the malignant polyp was approximately 4 mm, significantly smaller than the average 7.9 mm size of the benign polys (P = 0.031). Conclusion Cholecystectomy needs to be considered early in the management of small-sized gallbladder polyps, particularly in areas endemic for gallbladder carcinoma.
Collapse
Affiliation(s)
- Abhishek Gautam
- Department of Surgical Gastroenterology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Anshuman Pandey
- Department of Surgical Gastroenterology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Shakeel Masood
- Department of Surgical Gastroenterology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Smita Chauhan
- Department of Surgical Gastroenterology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Dinesh Choudhary
- Department of Surgical Gastroenterology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Suneed Kumar
- Department of Surgical Gastroenterology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Shibumon Madhawan
- Department of Surgical Gastroenterology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Sneha Jha
- Department of Surgical Gastroenterology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Vijay Saini
- Department of Surgical Gastroenterology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| |
Collapse
|
14
|
Yamamiya A, Irisawa A, Kashima K, Kunogi Y, Nagashima K, Minaguchi T, Izawa N, Yamabe A, Hoshi K, Tominaga K, Iijima M, Goda K. Interobserver Reliability of Endoscopic Ultrasonography: Literature Review. Diagnostics (Basel) 2020; 10:E953. [PMID: 33203069 PMCID: PMC7696989 DOI: 10.3390/diagnostics10110953] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 11/10/2020] [Accepted: 11/12/2020] [Indexed: 12/12/2022] Open
Abstract
Endoscopic ultrasonography (EUS) has been applied to the diagnosis of various digestive disorders. Although it has been widely accepted and its diagnostic value is high, the dependence of EUS diagnosis on image interpretation done by the endosonographer has persisted as an important difficulty. Consequently, high interobserver reliability (IOR) in EUS diagnosis is important to demonstrate the reliability of EUS diagnosis. We reviewed the literature on the IOR of EUS diagnosis for various diseases such as chronic pancreatitis, pancreatic solid/cystic mass, lymphadenopathy, and gastrointestinal and subepithelial lesions. The IOR of EUS diagnosis differs depending on the disease; moreover, EUS findings with high IOR and those with IOR that was not necessarily high were used as diagnostic criteria. Therefore, to further increase the value of EUS diagnosis, EUS diagnostic criteria with high diagnostic characteristics based on EUS findings with high IOR must be established.
Collapse
Affiliation(s)
| | - Atsushi Irisawa
- Department of Gastroenterology, Dokkyo Medical University School of Medicine, 880 Kitakobayashi Mibu, Tochigi 321-0293, Japan; (A.Y.); (K.K.); (Y.K.); (K.N.); (T.M.); (N.I.); (A.Y.); (K.H.); (K.T.); (M.I.); (K.G.)
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Behzadmehr R, Salarzaei M. Is contrast enhanced ultrasonography an accurate way to diagnose gallbladder adenoma? A systematic review and meta-analysis. J Med Imaging Radiat Sci 2020; 52:127-136. [PMID: 33129756 DOI: 10.1016/j.jmir.2020.09.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 08/26/2020] [Accepted: 09/29/2020] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Gallbladder adenoma (GA) is a precancerous neoplasm and needs surgical resection. It is difficult to differentiate adenoma from other gallbladder polyps using imaging examinations. The aim of present systematic review and meta-analysis was to evaluate the diagnostic accuracy of contrast-enhanced ultrasound in the diagnosis of gallbladder adenoma. METHODS The searches were conducted by two independent researchers to find the relevant studies published from 1/1/2009 until end of 30/06/2019. The search included published literature in the English language in MEDLINE via PubMed, EMBASE via Ovid, The Cochrane Library, and Trip databases. For literature published in other languages, national databases (Magiran and SID), KoreaMed, and LILACS were searched. The risk of bias of every article was evaluated by using QUADAS-2. On the basis of the results from the 2 × 2 tables, pooled measures for sensitivity, specificity, diagnostic odds ratio (DOR), and area under the curves (AUC) along with their 95% confidence intervals (CIs) were calculated using the DerSimonian Lair methodology. RESULTS Overall, 868 patients were studied in the 10 studies chosen for inclusion. Of these 10 studies, 5 (50%) were retrospective and 5 (50%) were prospective. The total prevalence of gallbladder adenoma in 10 studies was 16% (95% CI 13%, 18%). The sensitivity and specificity of contrast-enhanced ultrasound were 0.846 (95% CI 0.818-0.871) and 0.870 (95% CI: 0.844-0.894), respectively. The diagnostic odds ratio was 40.807 (95% CI 18.838-88.393). CONCLUSION CEUS is a reliable, non-invasive, and no-radiation-exposure imaging modality with a high sensitivity and specificity for detection of gallbladder adenoma. Nonetheless, it should be applied cautiously, and large scale, well-designed trials are necessary to assess its clinical value.
Collapse
Affiliation(s)
- Razieh Behzadmehr
- Associate Professor of Radiology, Zabol University of Medical Sciences, Zabol, Iran
| | - Morteza Salarzaei
- Student Research Committee, Zabol University of Medical Sciences, Zabol, Iran.
| |
Collapse
|
16
|
Abstract
Gallbladder (GB) polyp is a mucosal projection into the GB lumen. With increasing health awareness, GB polyps are frequently found using ultrasonography during health screening. The prevalence of GB polyps ranges between 1.3% and 9.5%. Most patients are asymptomatic and have benign characteristics. Of the nonneoplastic polyps, cholesterol polyps are most common, accounting for 60%-70% of lesions. However, a few polyps have malignant potential. Currently, the guidelines recommend laparoscopic cholecystectomy for polyps larger than 1 cm in diameter due to their malignan potential. The treatment algorithm can be influenced by the size, shape, and numbers of polyps, old age (>50 years), the presence of primary sclerosing cholangitis, and gallstones. This review summarizes the commonly recognized concepts on GB polyps from diagnosis to an algorithm of treatment.
Collapse
Affiliation(s)
- Kook Hyun Kim
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Yeungnam University College of Medicine, Daegu, Korea
| |
Collapse
|
17
|
Yuan HX, Yu QH, Zhang YQ, Yu Q, Zhang Q, Wang WP. Ultrasound Radiomics Effective for Preoperative Identification of True and Pseudo Gallbladder Polyps Based on Spatial and Morphological Features. Front Oncol 2020; 10:1719. [PMID: 33042816 PMCID: PMC7518113 DOI: 10.3389/fonc.2020.01719] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Accepted: 07/31/2020] [Indexed: 12/12/2022] Open
Abstract
Purpose: To explore the value of ultrasound radiomics in the preoperative identification of true and pseudo gallbladder polyps and to evaluate the associated diagnostic accuracy. Methods: Totally, 99 pathologically proven gallbladder polyps in 96 patients were enrolled, including 58 cholesterol polyps (55 patients) and 41 gallbladder tubular adenomas (41 patients). Features on preoperative ultrasound images, including spatial and morphological features, were acquired for each lesion. Following this, two-stage feature selection was adopted using Fisher's inter-intraclass variance ratios and Z-scores for the selection of intrinsic features important for differential diagnosis achievement with support vector machine use. Results: Eighty radiomic features were extracted from each polyp. Eight intrinsic features were identified after two-stage selection. The contrast 14 (Cont14) and entropy 6 (Entr6) values in the cholesterol polyp group were significantly higher than those in the gallbladder adenoma group (4.063 ± 1.682 vs. 2.715 ± 1.867, p < 0.001 for Cont14; 4.712 ± 0.427 vs. 4.380 ± 0.720, p = 0.003 for Entr6); however, the homogeneity 13 (Homo13) and energy 8 (Ener8) values in the cholesterol polyp group were significantly lower (0.500 ± 0.069 vs. 0.572 ± 0.057, p < 0.001 for Homo13; 0.050 ± 0.023 vs. 0.068 ± 0.038, p = 0.002 for Ener8). These results indicate that the pixel distribution of cholesterol polyps was more uneven than that of gallbladder tubular adenomas. The dispersion degree was also significantly lower in the cholesterol polyp group than the gallbladder adenoma group (0.579 ± 0.054 vs. 0.608 ± 0.041, p = 0.005), indicating a lower dispersion of high-intensity areas in the cholesterol polyps. The long axis length of the fitting ellipse (Maj.Len), diameter of a circle equal to the lesion area (Eq.Dia) and perimeter (Per) values in the cholesterol polyp group were significantly lower than those in the gallbladder adenoma group (0.971 ± 0.485 vs. 1.738 ± 0.912, p < 0.001 for Maj.Len; 0.818 ± 0.393 vs. 1.438 ± 0.650, p < 0.001 for Eq.Dia; 2.637 ± 1.281 vs. 5.033 ± 2.353, p < 0.001 for Per), demonstrating that the cholesterol polyps were smaller and more regular in terms of morphology. The classification accuracy, sensitivity, specificity, and area under the curve values were 0.875, 0.885, 0.857, and 0.898, respectively. Conclusions: Ultrasound radiomic analysis based on the spatial and morphological features extracted from ultrasound images effectively contributed to the preoperative diagnosis of true and pseudo gallbladder polyps and may be valuable in their clinical management.
Collapse
Affiliation(s)
- Hai-Xia Yuan
- Department of Ultrasound, Zhongshan Hospital of Fudan University, Shanghai, China.,Department of Ultrasound, Xiamen Branch, Zhongshan Hospital of Fudan University, Xiamen, China
| | - Qi-Hui Yu
- The SMART (Smart Medicine and AI-based Radiology Technology) Lab, School of Communication and Information Engineering, Shanghai University, Shanghai, China
| | - Yan-Qun Zhang
- Department of Ultrasound, Zhongshan Hospital of Fudan University, Shanghai, China.,Department of Ultrasound, Xiamen Branch, Zhongshan Hospital of Fudan University, Xiamen, China
| | - Qing Yu
- Shanghai Institute of Medical Imaging, Shanghai, China
| | - Qi Zhang
- The SMART (Smart Medicine and AI-based Radiology Technology) Lab, School of Communication and Information Engineering, Shanghai University, Shanghai, China.,Hangzhou YITU Healthcare Technology, Hangzhou, China
| | - Wen-Ping Wang
- Department of Ultrasound, Zhongshan Hospital of Fudan University, Shanghai, China.,Department of Ultrasound, Xiamen Branch, Zhongshan Hospital of Fudan University, Xiamen, China.,Shanghai Institute of Medical Imaging, Shanghai, China
| |
Collapse
|
18
|
Yang X, Liu Y, Guo Y, Chai R, Niu M, Xu K. Utility of radiomics based on contrast-enhanced CT and clinical data in the differentiation of benign and malignant gallbladder polypoid lesions. Abdom Radiol (NY) 2020; 45:2449-2458. [PMID: 32166337 DOI: 10.1007/s00261-020-02461-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
PURPOSE To develop and validate a novel method based on radiomics for the preoperative differentiation of benign and malignant gallbladder polypoid lesions (PLG). PATIENTS AND METHODS A total of 145 patients with pathological proven gallbladder polypoid lesions ≥ 1 cm were included in this retrospective study. All the patients underwent abdominal contrast-enhanced computed tomography (CT) examinations 3 weeks before cholecystectomy from January 2013 to January 2019. Seventy percent of the cases were randomly selected for the training dataset, and 30% of the cases were independently used for testing. Radiomics features extracted from portal venous-phase CT of the PLG and clinical features were analyzed, and the LASSO regression algorithm was used for data dimension reduction. Multivariable logistic regression was used to generate radiomics signatures, clinical signatures, and combination signatures. The receiver operating characteristic (ROC) curve and decision curve were plotted to assess the differentiating performance of the three signatures. RESULTS The area under the ROC curve (AUC) of the radiomics signature and clinical signature was 0.924 and 0.861 in the testing dataset, respectively. For the radiomics signature, the accuracy was 88.6%, with 88.0% specificity and 89.5% sensitivity. When combined, the AUC was 0.931, the specificity was 84.0%, and the sensitivity was 89.5%. The differences between the AUC values of the two sole models and the combination model were statistically nonsignificant. CONCLUSION Radiomics based on CT images can be helpful to differentiate benign and malignant gallbladder polyps ≥ 1 cm in size.
Collapse
Affiliation(s)
- Xiaodong Yang
- Department of Radiology, The First Affiliated Hospital of China Medical University, No.155 Nanjing Road Heping Area, Shenyang, 110000, Liaoning Province, China
| | - Yi Liu
- Department of Radiology, The First Affiliated Hospital of China Medical University, No.155 Nanjing Road Heping Area, Shenyang, 110000, Liaoning Province, China
| | - Yan Guo
- GE Health, Shanghai, 200000, China
| | - Ruimei Chai
- Department of Radiology, The First Affiliated Hospital of China Medical University, No.155 Nanjing Road Heping Area, Shenyang, 110000, Liaoning Province, China
| | - Meng Niu
- Department of Radiology, The First Affiliated Hospital of China Medical University, No.155 Nanjing Road Heping Area, Shenyang, 110000, Liaoning Province, China
| | - Ke Xu
- Department of Radiology, The First Affiliated Hospital of China Medical University, No.155 Nanjing Road Heping Area, Shenyang, 110000, Liaoning Province, China.
| |
Collapse
|
19
|
Metman MJH, Olthof PB, van der Wal JBC, van Gulik TM, Roos D, Dekker JWT. Clinical relevance of gallbladder polyps; is cholecystectomy always necessary? HPB (Oxford) 2020; 22:506-510. [PMID: 31481314 DOI: 10.1016/j.hpb.2019.08.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 08/02/2019] [Accepted: 08/09/2019] [Indexed: 12/12/2022]
Abstract
BACKGROUND Gallbladder polyps are common incidental findings during abdominal ultrasonography. Cholecystectomy is recommended for polyps equal or greater than 10 mm on ultrasound due to their malignant potential. However, the majority of lesions appear to be pseudopolyps with no malignant potential. Our aim was to determine the correlation between ultrasonographic findings and histopathological findings after cholecystectomy for gallbladder polyps in two institutions. METHOD A retrospective analysis was performed at two Dutch institutions of patients who underwent cholecystectomy. All cholecystectomies for suspected gallbladder polyps between January 2010 and August 2017 were included. Ultrasonographic and histopathological reports were analyzed. RESULTS A total of 108 patients underwent cholecystectomy for gallbladder polyps. At abdominal ultrasound sixty-five patients (60.2%) were diagnosed with multiple gallbladder polyps. The mean diameter of the polyps was 11 mm. On pathological examination after cholecystectomy, only three specimens harbored true polyps. No anomalies were found in 48 (44%) patients and 51 (47%) had cholesterolosis. CONCLUSION The prevalence of true gallbladder polyps was much lower in this study than reported in literature. After cholecystectomy for gallbladder polyps diagnosed by ultrasound, 97% of patients had non-neoplastic or not identifiable lesions in the gallbladder. These findings question the usefulness of current guidelines for management of suspected gallbladder polyps.
Collapse
Affiliation(s)
- Madelon J H Metman
- Department of Surgery, Reinier de Graaf Gasthuis, Delft, the Netherlands.
| | - Pim B Olthof
- Department of Surgery, Reinier de Graaf Gasthuis, Delft, the Netherlands; Department of Surgery, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands; Department of Surgery, Erasmus Medical Center, Rotterdam, the Netherlands
| | | | - Thomas M van Gulik
- Department of Surgery, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands
| | - Daphne Roos
- Department of Surgery, Reinier de Graaf Gasthuis, Delft, the Netherlands
| | | |
Collapse
|
20
|
Saftoiu A, Napoleon B, Arcidiacono PG, Braden B, Burmeister S, Carrara S, Cui XW, Fusaroli P, Gottschalk U, Hocke M, Hollerbach S, Iglesias-Garcia J, Jenssen C, Kitano M, Larghi A, Oppong KW, Sahai AV, Sun S, Burmester E, Di Leo M, Petrone MC, Santos E, Teoh AYB, Hwang JH, Rimbas M, Sharma M, Puri R, Kahaleh M, Dietrich CF. Do we need contrast agents for EUS? Endosc Ultrasound 2020; 9:361-368. [PMID: 32675463 PMCID: PMC7811706 DOI: 10.4103/eus.eus_20_20] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
We recently introduced a series of articles that dealt with controversies in EUS. In Part I, the authors discussed which clinical information is necessary prior to EUS and whether other imaging modalities are required before embarking on EUS examinations. Part II focuses on technical details and controversies about the use of EUS in special situations. In this article, important practical issues regarding the application of contrast-enhanced EUS in various clinical settings are raised and controversially discussed from different points of view.
Collapse
Affiliation(s)
- Adrian Saftoiu
- Department of Gastroenterology, Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy of Craiova, Craiova, Romania
| | - Bertrand Napoleon
- Digestive Endoscopy Unit, Hopital Privé J Mermoz Ramsay Générale de Santé, Lyon, France
| | - Paolo Giorgio Arcidiacono
- Pancreatico/Biliary Endoscopy & Endosonography Division, Pancreas Translational & Clinical Research Center, San Raffaele Scientific Institute, Vita Salute San Raffaele University, Milan, Italy
| | - Barbara Braden
- Johann Wolfgang Goethe University Frankfurt, Germany; Translational Gastroenterology Unit I John Radcliffe Hospital I Oxford OX3 9DU UK
| | - Sean Burmeister
- Surgical Gastroenterology unit, Groote Schuur Hospital, Cape Town, South Africa
| | - Silvia Carrara
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center, Milan, Italy
| | - Xin Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, Hubei, China
| | - Pietro Fusaroli
- Department of Medical and Surgical Sciences, Gastroenterology Unit, University of Bologna/Imola Hospital, Imola, Italy
| | - Uwe Gottschalk
- Department of Medical, Dietrich Bonhoeffer Klinikum, Neubrandenburg, Germany
| | - Michael Hocke
- Medical Department, Helios Klinikum Meiningen, Germany
| | - Stephan Hollerbach
- Department of Gastroenterology, Allgemeines Krankenhaus Celle, Celle, Germany
| | - Julio Iglesias-Garcia
- Department of Gastroenterology and Hepatology, Health Research Institute of Santiago de Compostela (IDIS), University Hospital of Santiago de Compostela, Santiago de Compostela, Spain
| | - Christian Jenssen
- Department of Internal Medicine, Krankenhaus Märkisch Oderland Strausberg/Wriezen; Brandenburg Institute of Clinical Ultrasound, Medical University Brandenburg, Neuruppin, Germany
| | - Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Alberto Larghi
- Digestive Endoscopy Unit, Fondazione Policlinico A. Gemelli IRCCS, Rome, Italy
| | | | - Anand V Sahai
- Center Hospitalier de l'Université de Montréal, Montreal, Canada
| | - Siyu Sun
- Endoscopy Center, ShengJing Hospital of China Medical University, Shenyang, Liaoning province, China
| | | | - Milena Di Leo
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Clinical and Research Center, Milan, Italy
| | - Maria Chiara Petrone
- Pancreatico/Biliary Endoscopy & Endosonography Division, Pancreas Translational & Clinical Research Center, San Raffaele Scientific Institute, Vita Salute San Raffaele University, Milan, Italy
| | - Erwin Santos
- Department of Gastroenterology and Liver Diseases, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Anthony Y B Teoh
- Department of Surgery, The Prince of Wales Hospital, The Chinese University of Hong Kong, China
| | - Joo Ha Hwang
- Division of Gastroenterology and Hepatology, Stanford University, Stanford, CA 94305, USA
| | - Mihai Rimbas
- Gastroenterology Department, Colentina Clinical Hospital Internal Medicine Department, Carol Davila University of Medicine Bucharest, Romania
| | - Malay Sharma
- Department of Gastroenterology, Jaswant Rai Speciality Hospital, Meerut, Uttar Pradesh, India
| | - Rajesh Puri
- Interventional Gastroenterology, Institute of Digestive and Hepatobiliary Sciences Medanta the Medicity Gurugram, Haryana, India
| | - Michel Kahaleh
- Department of Gastroenterology, The State University of New Jersey, New Jersey, USA
| | - Christoph F Dietrich
- Johann Wolfgang Goethe University Frankfurt, Germany; Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, Hubei, China; Department Allgemeine Innere Medizin, Kliniken Hirslanden, Beau Site, Salem und Permanence, Bern, Switzerland
| |
Collapse
|
21
|
Chen T, Tu S, Wang H, Liu X, Li F, Jin W, Liang X, Zhang X, Wang J. Computer-aided diagnosis of gallbladder polyps based on high resolution ultrasonography. Comput Methods Programs Biomed. 2020;185:105118. [PMID: 31671340 DOI: 10.1016/j.cmpb.2019.105118] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 09/06/2019] [Accepted: 10/03/2019] [Indexed: 02/05/2023]
Abstract
BACKGROUND AND OBJECTIVE Gallbladder polyp is a common disease with an overall population prevalence between 4 and 7%. It can be classified as neoplastic and non-neoplastic lesions. Surgical treatment is necessary for neoplastic polyps. Due to its easy accessibility and nonradioactive, ultrasonography is the mostly used preoperative diagnosis tool for gallbladder polyps. However, human image analysis depends greatly on levels of experience, which results in many overtreatment cases and undertreatment cases in clinics. METHODS In this study, we proposed an ultrasound image segmentation algorithm, combined with principal components analysis (PCA) and AdaBoost algorithms to construct a computer-aided diagnosis system for the differentiate diagnosis of neoplastic and non-neoplastic gallbladder polyps. RESULTS The proposed segmentation method achieved a high accuracy of 95% for outlining the gallbladder region. The accuracy, sensitivity, specificity for the proposed computer-aided diagnosis system based on the segmented images are 87.54%, 86.52% and 89.40%, compared to 69.05%, 67.86% and 70.17% with convolutional neural network. The diagnosis result is also slightly higher than the human eyes of sonologists (86.22%, 85.19% and 89.18% as an average of four sonologists), while with a much faster diagnosis speed (0.02s vs 3s). CONCLUSIONS We proposed an efficient ultrasound image segmentation approach and a reliable system of automatic diagonals of neoplastic and non-neoplastic gallbladder polyps. The results show that the diagnosis accuracy is competitive to the expert sonologists while requires much less diagnosis time.
Collapse
|
22
|
Yamin Z, Xuesong B, Guibin Y, Liwei L, Fei L. Risk factors of gallbladder polyps formation in East Asian population: A meta-analysis and systematic review. Asian J Surg 2019; 43:52-59. [PMID: 31109764 DOI: 10.1016/j.asjsur.2019.03.015] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2018] [Revised: 02/21/2019] [Accepted: 03/20/2019] [Indexed: 02/07/2023] Open
Abstract
To perform Meta-analysis to identify risk factors associated with gallbladder polyps (GBP) formation in east Asian population. Three English electronic bibliographic databases includes PubMed, Embase and Medline, with reviewed researches from 1986 to 2017. All possible risk factors of GBP formation were recorded. Meta-analyses were performed by Review Manager Software. Pooled odds ratios (OR) or the mean difference (MD) were used to determine risk factors. Sixteen studies and 227021 people were recruited, including 17261 people with GBP and 209760 without GBP. For categorical variables evaluated by OR test., risk factors of GBP formation were male gender (OR, 1.63; 95%CI, 1.42-1.87) and positive HBsAg. GBP formation were not correlated with age <50 years old, hypertension, DM, BMI ≥ 25kg/m2, smoking, drinking, HDL decrease, TC increase, TG increase, fatty liver and GBS. For continuous variables evaluated by MD test, risk factors of GBP formation were DBP (MD, 1.08; 95%CI, 0.15-2.02), mean BMI (MD,0.19; 95%CI,0.02-0.35), waist circumference (MD,1.780; 95%CI, 0.17,3.40), mean LDL (MD,0.89; 95%CI,0.03-1.75), mean HDL (MD,-1.87; 95%CI,-3.21 to -0.52). GBP formation were not correlated with mean age, SBP, mean TC, mean TG, ASL and ALT. In conclusion, risk factors of gallbladder polyp formation included male gender, higher BMI, higher waist circumference, higher DBP, higher LDL, lower HDL and positive HBsAg in east Asian population. GBP formation was not correlated with age, hypertension, DM, smoking, drinking, fatty liver, GBS, TC, TG, SBP, ASL and ALT. The mechanism of Dyslipidemias causing GBP needs deeper study in future.
Collapse
Affiliation(s)
- Zheng Yamin
- Department of General Surgery, Xuanwu Hospital, Capital Medical University, Beijing, China.
| | - Bai Xuesong
- Xuanwu Hospital, The First Clinical Medical College, Capital Medical University, Beijing, China
| | - Yao Guibin
- Xuanwu Hospital, The First Clinical Medical College, Capital Medical University, Beijing, China
| | - Liu Liwei
- Xuanwu Hospital, The First Clinical Medical College, Capital Medical University, Beijing, China
| | - Li Fei
- Department of General Surgery, Xuanwu Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
23
|
Lin LY, Chiou HJ, Chou YH, Wang HK, Lai YC, Lin YH. A Case of Tubular Adenoma of Gallbladder Diagnosed Using Contrast-Enhanced Ultrasonography. J Med Ultrasound 2018; 26:218-221. [PMID: 30662155 PMCID: PMC6314087 DOI: 10.4103/jmu.jmu_47_18] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2018] [Accepted: 06/07/2018] [Indexed: 12/18/2022] Open
Abstract
Contrast-enhanced ultrasound (CEUS) has been used to diagnose gallbladder (GB) diseases for recent years because it is sensitive to visualize vascularity. Herein, we report a case who had a 1.7 cm × 1.2 cm polypoid lesion located in the gallbladder fundus with a feeding artery located in the stalk. On CEUS, the lesion showed early arterial phase enhancement (time to peak enhancement 18 s), persisting throughout the venous and delay phases. This enhancing pattern suggested that the lesion was a GB adenoma rather than a GB carcinoma. Cholecystectomy was performed, and pathology of the tissue revealed tubular adenoma of the GB.
Collapse
Affiliation(s)
- Lo-Yi Lin
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Hong-Jen Chiou
- Division of Ultrasound and Breast Imaging, Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan.,School of Medicine, National Yang Ming University, Taipei, Taiwan.,National Defense Medical Center, Taipei, Taiwan
| | - Yi-Hong Chou
- Division of Ultrasound and Breast Imaging, Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan.,School of Medicine, National Yang Ming University, Taipei, Taiwan
| | - Hsin-Kai Wang
- Division of Ultrasound and Breast Imaging, Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Yi-Chen Lai
- Division of Ultrasound and Breast Imaging, Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Yun-Hui Lin
- Division of Ultrasound and Breast Imaging, Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
| |
Collapse
|
24
|
Cokkinos DD, Antypa EG, Tsolaki S, Skylakaki M, Skoura A, Mellou V, Kalogeropoulos I. Contrast-enhanced ultrasound examination of the gallbladder and bile ducts: A pictorial essay. J Clin Ultrasound 2018; 46:48-61. [PMID: 28984361 DOI: 10.1002/jcu.22537] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2017] [Revised: 07/25/2017] [Accepted: 08/09/2017] [Indexed: 05/23/2023]
Abstract
The gallbladder and bile ducts are usually assessed initially with conventional gray-scale ultrasound (US). Contrast enhanced US (CEUS) is used when a diagnosis cannot be reached with conventional US. CEUS is easy to learn and perform. US contrast agents can be safely administered in patients with renal function impairment. In this pictorial essay the physics, examination technique and indications of CEUS for examining the gallbladder and bile ducts are reviewed. Gallbladder indications include elucidating normal variants, differentiating sludge from neoplastic lesions, benign and malignant pathology, infection, wall rupture and hemobilia. In the biliary tree CEUS is used for studying benign and malignant tumors, including metastases and cholangiocarcinoma, as well as intrabiliary injection.
Collapse
Affiliation(s)
| | - Eleni G Antypa
- Radiology Department, Evangelismos Hospital, Athens, Greece
| | - Sofia Tsolaki
- Radiology Department, Evangelismos Hospital, Athens, Greece
| | | | - Alkmini Skoura
- Radiology Department, Evangelismos Hospital, Athens, Greece
| | | | | |
Collapse
|
25
|
Kim SY, Cho JH, Kim EJ, Chung DH, Kim KK, Park YH, Kim YS. The efficacy of real-time colour Doppler flow imaging on endoscopic ultrasonography for differential diagnosis between neoplastic and non-neoplastic gallbladder polyps. Eur Radiol 2017; 28:1994-2002. [PMID: 29218621 DOI: 10.1007/s00330-017-5175-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2017] [Revised: 10/23/2017] [Accepted: 11/06/2017] [Indexed: 12/14/2022]
Abstract
OBJECTIVES We evaluated the usefulness of real-time colour Doppler flow (CDF) endoscopic ultrasonography (EUS) for differentiating neoplastic gallbladder (GB) polyps from non-neoplastic polyps. METHODS Between August 2014 and December 2016, a total of 233 patients with GB polyps who underwent real-time CDF-EUS were consecutively enrolled in this prospective study. CDF imaging was subjectively categorized for each patient as: strong CDF pattern, weak CDF pattern and no CDF pattern. RESULTS Of the 233 patients, 115 underwent surgical resection. Of these, there were 90 cases of non-neoplastic GB polyps and 23 cases of neoplastic GB polyps. In a multivariate analysis, a strong CDF pattern was the most significant predictive factor for neoplastic polyps; sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 52.2 %, 79.4 %, 38.7 %, 86.9 % and 73.9 %, respectively. Solitary polyp and polyp size were associated with an increased risk of neoplasm. CONCLUSIONS The presence of a strong CDF pattern as well as solitary and larger polyps on EUS may be predictive of neoplastic GB polyps. As real-time CDF-EUS poses no danger to the patient and requires no additional equipment, it is likely to become a supplemental tool for the differential diagnosis of GB polyps. KEY POINTS • Differential diagnosis between neoplastic polyps and non-neoplastic polyps of GB is limited. • The use of real-time CDF-EUS was convenient, with high agreement between operators. • The real-time CDF-EUS is helpful in differential diagnosis of GB polyps.
Collapse
Affiliation(s)
- Su Young Kim
- Division of Gastroenterology, Department of Internal Medicine, Gachon University, Gil Medical Center, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, Republic of Korea
| | - Jae Hee Cho
- Division of Gastroenterology, Department of Internal Medicine, Gachon University, Gil Medical Center, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, Republic of Korea.
| | - Eui Joo Kim
- Division of Gastroenterology, Department of Internal Medicine, Gachon University, Gil Medical Center, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, Republic of Korea
| | - Dong Hae Chung
- Department of Pathology, Gachon University, Gil Medical Center, Incheon, Republic of Korea
| | - Kun Kuk Kim
- Department of Surgery, Gachon University, Gil Medical Center, Incheon, Republic of Korea
| | - Yeon Ho Park
- Department of Surgery, Gachon University, Gil Medical Center, Incheon, Republic of Korea
| | - Yeon Suk Kim
- Division of Gastroenterology, Department of Internal Medicine, Gachon University, Gil Medical Center, 21, Namdong-daero 774beon-gil, Namdong-gu, Incheon, Republic of Korea
| |
Collapse
|
26
|
Chen LD, Huang Y, Xie XH, Chen W, Shan QY, Xu M, Liu JY, Nie ZQ, Xie XY, Lu MD, Shen SL, Wang W. Diagnostic nomogram for gallbladder wall thickening mimicking malignancy: using contrast-enhanced ultrasonography or multi-detector computed tomography? Abdom Radiol (NY) 2017; 42:2436-2446. [PMID: 28447109 DOI: 10.1007/s00261-017-1162-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
OBJECTIVES To establish a diagnostic nomogram using contrast-enhanced ultrasonography (CEUS) in gallbladder wall thickening mimicking malignancy and compare with multi-detector computed tomography (MDCT). METHODS Seventy-two patients with gallbladder wall thickening on B-mode ultrasonography (BUS) were examined by CEUS to develop independent predictors for diagnosing gallbladder carcinoma. Among the 72 cases, 48 patients underwent both CEUS and MDCT. The diagnostic performances of different sets of CEUS criteria and MDCT were compared. A prediction model of malignancy using CEUS was developed. The performance of the nomogram was assessed with respect to its calibration, discrimination, and clinical usefulness. RESULTS Multivariate logistic regression indicated that inhomogeneous enhancement in the arterial phase was the strongest independent predictor of malignancy (odds ratio, OR 51.162), followed by interrupted inner layer (OR 19.788), washout time ≤40 s (OR 16.686), and wall thickness >1.6 cm (OR 3.019), which were all selected into the nomogram. Combined with the above significant features, the diagnostic performance of CEUS (AUC = 0.917) was higher than that of MDCT (AUC = 0.788, P = 0.070). The predictive model using CEUS showed good discrimination, with a concordance index of 0.974 (0.950 through internal validation), and good calibration. Decision curve analysis demonstrated that the nomogram was clinically useful. CONCLUSIONS CEUS could accurately differentiate between malignant and benign gallbladder wall thickening with equivalent efficacy compared to MDCT. The proposed nomogram could be conveniently used to facilitate the preoperative individualized prediction of malignancy in patients with gallbladder wall thickening.
Collapse
Affiliation(s)
- Li-Da Chen
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou, 510080, China
| | - Yang Huang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou, 510080, China
| | - Xiao-Hua Xie
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou, 510080, China
| | - Wei Chen
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Quan-Yuan Shan
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou, 510080, China
| | - Ming Xu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou, 510080, China
| | - Jin-Ya Liu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou, 510080, China
| | - Zhi-Qiang Nie
- Department of Epidemiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academic of Medical Science, Guangzhou, China
| | - Xiao-Yan Xie
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou, 510080, China
| | - Ming-De Lu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou, 510080, China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Shun-Li Shen
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.
| | - Wei Wang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou, 510080, China.
| |
Collapse
|
27
|
Leem G, Chung MJ, Park JY, Bang S, Song SY, Chung JB, Park SW. Clinical Value of Contrast-Enhanced Harmonic Endoscopic Ultrasonography in the Differential Diagnosis of Pancreatic and Gallbladder Masses. Clin Endosc 2017; 51:80-88. [PMID: 28928356 PMCID: PMC5806916 DOI: 10.5946/ce.2017.044] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Revised: 07/03/2017] [Accepted: 07/06/2017] [Indexed: 11/30/2022] Open
Abstract
Background/Aims Recent studies have revealed that contrast-enhanced harmonic endoscopic ultrasonography (CEH-EUS) is beneficial in the differential diagnosis of malignant neoplasms of the pancreas and gallbladder from benign masses, in terms of the evaluation of microvasculature and real-time perfusion. In this study, we aimed to prove the clinical value of CEH-EUS in the differential diagnosis of pancreatic and gallbladder masses by direct comparison with that of conventional EUS.
Methods We reviewed the sonographic images and medical information of 471 patients who underwent conventional EUS and CEH-EUS for the diagnosis of pancreatic and gallbladder masses at a single medical center (Severance Hospital, Seoul, Korea) between March 2010 and March 2016.
Results The enhancement pattern of CEH-EUS of the pancreatic solid masses showed higher sensitivity and specificity in differentiating pancreatic adenocarcinoma and neuroendocrine tumors (82.0% and 87.9% for pancreatic adenocarcinoma and 81.1% and 90.9% for neuroendocrine tumors, respectively), and the area under the receiver operating characteristic curves was higher than that of conventional EUS. The enhancement texture of CEH-EUS of the gallbladder masses showed a higher sensitivity in differentiating malignant masses than that of conventional EUS; however, the difference between the areas under the receiver operating characteristic curves was not statistically significant.
Conclusions CEH-EUS can complement conventional EUS in the diagnosis of pancreatic and gallbladder masses, in terms of the limitations of the latter.
Collapse
Affiliation(s)
- Galam Leem
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Moon Jae Chung
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Jeong Youp Park
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Seungmin Bang
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Si Young Song
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Jae Bock Chung
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Seung Woo Park
- Division of Gastroenterology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
28
|
Sugimoto M, Takagi T, Suzuki R, Konno N, Asama H, Watanabe K, Nakamura J, Kikuchi H, Waragai Y, Takasumi M, Sato Y, Hikichi T, Ohira H. Contrast-enhanced harmonic endoscopic ultrasonography in gallbladder cancer and pancreatic cancer. Fukushima J Med Sci 2017; 63:39-45. [PMID: 28680009 DOI: 10.5387/fms.2017-04] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Endoscopic ultrasonography (EUS) plays a major role in diagnosing gallbladder (GB) cancer and pancreatic cancer (PC). In cases of GB cancer, EUS allows for precise observations of morphology and wall layers. However, proficiency is required for the morphologic diagnosis of GB tumors. Therefore, contrast-enhanced harmonic EUS (CH-EUS) began to be performed to diagnose GB lesions. CH-EUS enables real-time observation of the hemodynamics of GB tumors. The enhanced patterns generated by CH-EUS improve precision in the diagnosis of such tumors.PC appears as a hypoechoic mass on EUS. However, distinguishing between PC and mass-forming pancreatitis or focal autoimmune pancreatitis (AIP) is difficult via conventional EUS. CH-EUS allows for differentiating among these diseases (PC is hypoenhanced and heterogeneously enhanced, pancreatitis is isoenhanced, and a pancreatic neuroendocrine tumor is hyperenhanced). EUS-guided fine needle aspiration (EUS-FNA) also contributes to pathological diagnoses of pancreatic lesions. However, certain PC patients cannot be diagnosed via EUS-FNA. PC is heterogeneously enhanced on CH-EUS, and unenhanced regions have been reported to be areas of fibrosis or necrosis. CH-EUS-guided fine needle aspiration (CH-EUS-FNA) permits puncturing of the enhanced area while avoiding necrotic and fibrotic regions. Moreover, as CH-EUS findings have been quantitatively analyzed, a time-intensity curve (TIC) has become usable for diagnosing solid pancreatic lesions. CH-EUS-related techniques have been developed and increasingly utilized in the pancreaticobiliary area.
Collapse
Affiliation(s)
- Mitsuru Sugimoto
- Department of Gastroenterology, Fukushima Medical University, School of Medicine
| | - Tadayuki Takagi
- Department of Gastroenterology, Fukushima Medical University, School of Medicine
| | - Rei Suzuki
- Department of Gastroenterology, Fukushima Medical University, School of Medicine
| | - Naoki Konno
- Department of Gastroenterology, Fukushima Medical University, School of Medicine
| | - Hiroyuki Asama
- Department of Gastroenterology, Fukushima Medical University, School of Medicine
| | - Ko Watanabe
- Department of Gastroenterology, Fukushima Medical University, School of Medicine.,Department of Endoscopy, Fukushima Medical University Hospital
| | - Jun Nakamura
- Department of Gastroenterology, Fukushima Medical University, School of Medicine.,Department of Endoscopy, Fukushima Medical University Hospital
| | - Hitomi Kikuchi
- Department of Gastroenterology, Fukushima Medical University, School of Medicine.,Department of Endoscopy, Fukushima Medical University Hospital
| | - Yuichi Waragai
- Department of Gastroenterology, Fukushima Medical University, School of Medicine
| | - Mika Takasumi
- Department of Gastroenterology, Fukushima Medical University, School of Medicine
| | - Yuki Sato
- Department of Gastroenterology, Fukushima Medical University, School of Medicine
| | - Takuto Hikichi
- Department of Endoscopy, Fukushima Medical University Hospital
| | - Hiromasa Ohira
- Department of Gastroenterology, Fukushima Medical University, School of Medicine
| |
Collapse
|
29
|
Chae HD, Lee JY, Jang JY, Chang JH, Kang J, Kang MJ, Han JK. Photoacoustic Imaging for Differential Diagnosis of Benign Polyps versus Malignant Polyps of the Gallbladder: A Preliminary Study. Korean J Radiol 2017; 18:821-827. [PMID: 28860899 PMCID: PMC5552465 DOI: 10.3348/kjr.2017.18.5.821] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Accepted: 04/04/2017] [Indexed: 12/13/2022] Open
Abstract
OBJECTIVE To investigate the feasibility of ex vivo multispectral photoacoustic (PA) imaging in differentiating cholesterol versus neoplastic polyps, and benign versus malignant polyps, of the gallbladder. MATERIALS AND METHODS A total of 38 surgically confirmed gallbladder polyps (24 cholesterol polyps, 4 adenomas, and 10 adenocarcinomas) from 38 patients were prospectively included in this study. The surgical specimens were set on a gel pad immersed in a saline-filled container. The PA intensities of polyps were then measured, using two separate wavelength intervals (421-647 nm and 692-917 nm). Mann-Whitney U test was performed for the comparison of normalized PA intensities between the cholesterol and neoplastic polyps, and between the benign and malignant polyps. Kruskal-Wallis test was conducted for the comparison of normalized PA intensities among the cholesterol polyps, adenomas, and adenocarcinomas. RESULTS A significant difference was observed in the normalized PA intensities between the cholesterol and neoplastic polyps at 459 nm (median, 1.00 vs. 0.73; p = 0.032). Comparing the benign and malignant polyps, there were significant differences in the normalized PA intensities at 765 nm (median, 0.67 vs. 0.78; p = 0.013), 787 nm (median, 0.65 vs. 0.77; p = 0.034), and 853 nm (median, 0.59 vs. 0.85; p = 0.028). The comparison of the normalized PA intensities among cholesterol polyps, adenomas, and adenocarcinomas demonstrated marginally significant differences at 765 nm (median, 0.67 vs. 0.66 vs. 0.78, respectively; p = 0.049). CONCLUSION These preliminary results indicate that benign versus malignant gallbladder polyps might exhibit different spectral patterns on multispectral PA imaging.
Collapse
Affiliation(s)
- Hee-Dong Chae
- Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital, Seoul 03080, Korea
| | - Jae Young Lee
- Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital, Seoul 03080, Korea
| | - Jin-Young Jang
- Division of Hepatobiliary-Pancreatic Surgery, Department of Surgery, Seoul National University College of Medicine, Seoul 03080, Korea
| | - Jin Ho Chang
- Sogang Institute of Advanced Technology, Sogang University, Seoul 04107, Korea.,Department of Biomedical Engineering, Sogang University, Seoul 04107, Korea
| | - Jeeun Kang
- Department of Electronic Engineering, Sogang University, Seoul 04107, Korea
| | - Mee Joo Kang
- Division of Hepatobiliary-Pancreatic Surgery, Department of Surgery, Seoul National University College of Medicine, Seoul 03080, Korea
| | - Joon Koo Han
- Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital, Seoul 03080, Korea
| |
Collapse
|
30
|
Seicean A, Mosteanu O, Seicean R. Maximizing the endosonography: The role of contrast harmonics, elastography and confocal endomicroscopy. World J Gastroenterol 2017; 23:25-41. [PMID: 28104978 PMCID: PMC5221284 DOI: 10.3748/wjg.v23.i1.25] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Revised: 11/17/2016] [Accepted: 12/08/2016] [Indexed: 02/07/2023] Open
Abstract
New technologies in endoscopic ultrasound (EUS) evaluation have been developed because of the need to improve the EUS and EUS-fine needle aspiration (EUS-FNA) diagnostic rate. This paper reviews the principle, indications, main literature results, limitations and future expectations for each of the methods presented. Contrast-enhanced harmonic EUS uses a low mechanical index and highlights slow-flow vascularization. This technique is useful for differentiating solid and cystic pancreatic lesions and assessing biliary neoplasms, submucosal neoplasms and lymph nodes. It is also useful for the discrimination of pancreatic masses based on their qualitative patterns; however, the quantitative assessment needs to be improved. The detection of small solid lesions is better, and the EUS-FNA guidance needs further research. The differentiation of cystic lesions of the pancreas and the identification of the associated malignancy features represent the main indications. Elastography is used to assess tissue hardness based on the measurement of elasticity. Despite its low negative predictive value, elastography might rule out the diagnosis of malignancy for pancreatic masses. Needle confocal laser endomicroscopy offers useful information about cystic lesions of the pancreas and is still under evaluation for use with solid pancreatic lesions of lymph nodes.
Collapse
|
31
|
Abstract
Over the last decade, the clinical applications of contrast-enhanced harmonic endoscopic ultrasound (CH-EUS) have increased steadily. The development of second-generation ultrasound contrast agents has allowed superior visualization of the microvasculature and tissue perfusion of the target lesion. This methodology has proven useful in the differential diagnosis of solid pancreatic masses and lymph nodes. In addition, the applicability of CH-EUS has expanded to nonpancreas structures such as biliary, focal liver lesions, and vascular disease. This article focuses primarily on the novel applications of CH-EUS in biliary tract and visceral vascular diseases.
Collapse
Affiliation(s)
- Jun-Ho Choi
- Department of Internal Medicine, Dankook University College of Medicine, Dankook University Hospital, Seoul, South Korea
| | - Dong-Wan Seo
- Department of Internal Medicine, Division of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| |
Collapse
|
32
|
Tang RSY. Contrast-enhanced endoscopic ultrasound for pancreatobiliary disease. Int J Gastrointest Interv 2016. [DOI: 10.18528/gii160017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Affiliation(s)
- Raymond Shing-Yan Tang
- Institute of Digestive Disease, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
33
|
Fusaroli P, Napoleon B, Gincul R, Lefort C, Palazzo L, Palazzo M, Kitano M, Minaga K, Caletti G, Lisotti A. The clinical impact of ultrasound contrast agents in EUS: a systematic review according to the levels of evidence. Gastrointest Endosc 2016; 84:587-596.e10. [PMID: 27311654 DOI: 10.1016/j.gie.2016.06.006] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Accepted: 06/02/2016] [Indexed: 02/06/2023]
Abstract
BACKGROUND AND AIMS The use of contrast-harmonic EUS (CH-EUS) in routine clinical practice is increasing rapidly but is not yet standardized. We present the levels of evidence (LEs) found in the literature to put its clinical outcomes in the appropriate perspective. METHODS We conducted a systematic review of the available English-language articles. The LEs were stratified according to the Oxford Centre for Evidence-Based Medicine guidelines. RESULTS Overall, 210 articles were included and presented according to different pathologic conditions. For pancreatic solid neoplasms, the pooled sensitivity and specificity in the diagnosis of pancreatic carcinoma were very high (LE 1); quantitative analysis and guidance of FNA were reported as investigational research (LE 2-3). For pancreatic cystic lesions, the identification of neoplastic solid components as hyperenhanced lesions represented a promising application of CH-EUS (LE 2). For lymph nodes, CH-EUS increased the diagnostic yield of B-mode EUS for the detection of malignancy (LE 2). For submucosal tumors, CH-EUS seemed useful for differential diagnosis and risk stratification (LE 2-3). For other applications, differential diagnosis of gallbladder and vascular abnormalities by CH-EUS were reported (LE 2-3). CONCLUSIONS The LEs of CH-EUS in the literature have evolved from the initial descriptive studies to multicenter and prospective trials, and even meta-analyses. The differential diagnosis between benign and malignant lesions is the main field of application of CH-EUS. With regard to pancreatic solid neoplasms, the concomitant use of both CH-EUS and EUS-FNA may have additive value in increasing the overall accuracy by overcoming the false-negative results associated with each individual technique. Other applications are promising but still investigational.
Collapse
Affiliation(s)
- Pietro Fusaroli
- Gastroenterology Unit, Hospital of Imola, University of Bologna, Bologna, Italy
| | - Bertrand Napoleon
- Department of Gastroenterology, Private Hospital Jean Mermoz, Lyon, France
| | - Rodica Gincul
- Department of Gastroenterology, Private Hospital Jean Mermoz, Lyon, France
| | - Christine Lefort
- Department of Gastroenterology, Private Hospital Jean Mermoz, Lyon, France
| | | | | | - Masayuki Kitano
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Kosuke Minaga
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Giancarlo Caletti
- Gastroenterology Unit, Hospital of Imola, University of Bologna, Bologna, Italy
| | - Andrea Lisotti
- Gastroenterology Unit, Hospital of Imola, University of Bologna, Bologna, Italy
| |
Collapse
|
34
|
Chantarojanasiri T, Hirooka Y, Kawashima H, Ohno E, Kongkam P, Goto H. The role of endoscopic ultrasound in the diagnosis of gallbladder diseases. J Med Ultrason (2001) 2017; 44:63-70. [PMID: 27619811 DOI: 10.1007/s10396-016-0742-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Accepted: 08/15/2016] [Indexed: 12/13/2022]
Abstract
Endoscopic ultrasound (EUS) has recently played an increasing role in the diagnosis of gallbladder diseases. This review aims to summarize the role of EUS in the diagnosis of gallbladder lesions. EUS provides high-resolution images that can improve the diagnosis of gallbladder polypoid lesions and microlithiasis, in addition to evaluating gallbladder thickness and staging of gallbladder carcinoma. Contrast-enhancing agents may be useful for the differential diagnosis of gallbladder lesions, but the evidence of their effectiveness is still limited and further studies are required in this area to establish its usefulness. Endoscopic ultrasound combined with fine needle aspiration has played an increasing role in providing histological diagnosis of gallbladder tumors in addition to gallbladder thickening.
Collapse
|
35
|
Abstract
Since its introduction into clinical practice in the 1980s, endoscopic ultrasound (EUS) has been described as a good imaging modality for the diagnosis of pancreatobiliary diseases. However, differential diagnosis of certain lesions based only on B-mode ultrasound images can be challenging. Clinical use of ultrasound contrast agents has expanded the utility of EUS from that of detection to characterization of pancreatobiliary lesions based on the enhancement features of contrast-enhanced EUS (CE-EUS). Current low mechanical index techniques for CE-EUS using second-generation contrast agents have a number of distinct advantages over conventional diagnostic modalities in evaluating pancreatobiliary lesions, including real-time assessment of perfusion pattern, availability, and the absence of exposure to radiation. This article describes the technical aspects of CE-EUS and reviews the expanding indications in pancreatobiliary diseases and further development of this technique.
Collapse
Affiliation(s)
- Jun-Ho Choi
- Department of Internal Medicine, Dankook University College of Medicine, Cheonan, Korea
| | - Dong Wan Seo
- Division of Gastroenterology, Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
36
|
Sugimoto M, Takagi T, Konno N, Suzuki R, Asama H, Hikichi T, Watanabe K, Waragai Y, Kikuchi H, Takasumi M, Ohira H. The efficacy of contrast-enhanced harmonic endoscopic ultrasonography in diagnosing gallbladder cancer. Sci Rep 2016; 6:25848. [PMID: 27162097 PMCID: PMC4861928 DOI: 10.1038/srep25848] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Accepted: 04/25/2016] [Indexed: 12/17/2022] Open
Abstract
The aim of this study was to review the efficacy of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) in diagnosing gallbladder (GB)-protruded lesions. Thirty-eight patients underwent CH-EUS for the diagnosis of GB-protruded lesions. Twenty-four patients whose major axes of their largest lesions were longer than 10 mm were recruited. The ability of CH-EUS to diagnose malignant or benign lesions was reviewed. We treated lesions with brindled enhanced patterns as malignant and those with uniformly enhanced or unenhanced patterns as benign. Furthermore, three gastroenterologists who were not familiar with pancreaticobiliary EUS compared the diagnostic abilities of CH-EUS and conventional EUS using photographs. The sensitivity, specificity, and malignant accuracy of CH-EUS were 100, 94.4, and 95.8%, respectively. The number of lesions that presented with enhanced patterns was significantly different between the malignant lesions and the benign lesions (P < 0.001). In the comparison of diagnostic abilities between CH-EUS and conventional EUS by the three gastroenterologists, CH-EUS was significantly superior to conventional EUS in terms of sensitivity, specificity, and accuracy (76.1 vs. 42.9%, P = 0.029; 66.7 vs. 39.2%, P = 0.005; and 69.4 vs. 40.3%, P < 0.001; respectively). In conclusion, CH-EUS was useful for diagnosing malignant and benign GB-protruded lesions.
Collapse
Affiliation(s)
- Mitsuru Sugimoto
- Department of Gastroenterology and Rheumatology, Fukushima Medical University, School of Medicine, Fukushima, Japan
| | - Tadayuki Takagi
- Department of Gastroenterology and Rheumatology, Fukushima Medical University, School of Medicine, Fukushima, Japan
| | - Naoki Konno
- Department of Gastroenterology and Rheumatology, Fukushima Medical University, School of Medicine, Fukushima, Japan
| | - Rei Suzuki
- Department of Gastroenterology and Rheumatology, Fukushima Medical University, School of Medicine, Fukushima, Japan
| | - Hiroyuki Asama
- Department of Gastroenterology and Rheumatology, Fukushima Medical University, School of Medicine, Fukushima, Japan
| | - Takuto Hikichi
- Department of Endoscopy, Fukushima Medical University Hospital, Fukushima, Japan
| | - Ko Watanabe
- Department of Gastroenterology and Rheumatology, Fukushima Medical University, School of Medicine, Fukushima, Japan.,Department of Endoscopy, Fukushima Medical University Hospital, Fukushima, Japan
| | - Yuichi Waragai
- Department of Gastroenterology and Rheumatology, Fukushima Medical University, School of Medicine, Fukushima, Japan.,Department of Endoscopy, Fukushima Medical University Hospital, Fukushima, Japan
| | - Hitomi Kikuchi
- Department of Gastroenterology and Rheumatology, Fukushima Medical University, School of Medicine, Fukushima, Japan
| | - Mika Takasumi
- Department of Gastroenterology and Rheumatology, Fukushima Medical University, School of Medicine, Fukushima, Japan
| | - Hiromasa Ohira
- Department of Gastroenterology and Rheumatology, Fukushima Medical University, School of Medicine, Fukushima, Japan
| |
Collapse
|
37
|
Zhao Y, Qian L, Li P, Zhang S. The diagnostic value of endoscopic ultrasonography and contrast-enhanced harmonic endoscopic ultrasonography in gastrointestinal stromal tumors. Endosc Ultrasound 2016; 5:111-7. [PMID: 27080610 PMCID: PMC4850790 DOI: 10.4103/2303-9027.180475] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Objective: To evaluate the diagnostic value of endoscopic ultrasonography (EUS) and contrast-enhanced harmonic (CEH) EUS in patients with gastrointestinal stromal tumors (GISTs). Patients and Methods: About 19 patients with suspected GISTs underwent EUS and CEH-EUS before tumor resection. The malignant potential was assessed according to the modified Fletcher classification system. Patients were divided into lower (Group I) and higher (Group II) malignant potential group. The clinical characteristics and EUS/CEH-EUS features were compared between two groups. Results: The tumor size in Group II was significantly larger than that in Group I (14.6 ± 5.8 mm vs. 32.1 ± 8.4 mm, P < 0.05). Heterogeneous echogenicity was observed in 4 (4/8) cases in Group II and none in Group I (P < 0.05). Irregular intratumoral vessels were detected in 6 cases in Group II and none in Group I (P < 0.05). The sensitivity and specificity of irregular vessel detection for discriminating higher from lower malignant potential GISTs were 75% and 100%, respectively. The positive predictive value and negative predictive value of detection of irregular vessels to high malignant potential GISTs were 33% and 100%, respectively. Conclusion: Detection of irregular intratumoral vessels can predict higher malignant potential before tumor resection. The tumor size and echogenicity are assistant factors for malignant potential assessment. Endoscopic resection is an efficacious treatment with good security for appropriate patients.
Collapse
Affiliation(s)
| | - Linxue Qian
- Department of Ultrasound, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing, China
| | | | - Shutian Zhang
- Department of Gastroenterology and Hepatology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing, China
| |
Collapse
|
38
|
Kamata K, Kitano M, Omoto S, Kadosaka K, Miyata T, Minaga K, Yamao K, Imai H, Kudo M. New endoscopic ultrasonography techniques for pancreaticobiliary diseases. Ultrasonography 2016; 35:169-79. [PMID: 27214660 PMCID: PMC4939715 DOI: 10.14366/usg.15042] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Revised: 04/10/2016] [Accepted: 04/12/2016] [Indexed: 12/20/2022] Open
Abstract
Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS. EUS-guided fine needle aspiration (EUS-FNA) has been used for diagnosing pancreatic tumors. In order to improve the histological diagnostic yield, a EUS-FNA needle with a core trap has recently been developed. Contrast-enhanced harmonic EUS is a new imaging modality that uses an ultrasonographic contrast agent to visualize blood flow in fine vessels. This technique is useful in the diagnosis of pancreatic solid lesions and in confirming the presence of vascularity in mural nodules for cystic lesions. EUS elastography analyzes several different variables to measure tissue elasticity, color patterns, and strain ratio, using analytical techniques such as hue-histogram analysis, and artificial neural networks, which are useful for the diagnosis of chronic pancreatitis and pancreatic cancer.
Collapse
Affiliation(s)
- Ken Kamata
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Masayuki Kitano
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Shunsuke Omoto
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Kumpei Kadosaka
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Takeshi Miyata
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Kosuke Minaga
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Kentaro Yamao
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Hajime Imai
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Masatoshi Kudo
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| |
Collapse
|
39
|
Hammad AY, Miura JT, Turaga KK, Johnston FM, Hohenwalter MD, Gamblin TC. A literature review of radiological findings to guide the diagnosis of gallbladder adenomyomatosis. HPB (Oxford) 2016; 18:129-135. [PMID: 26902131 PMCID: PMC4814619 DOI: 10.1016/j.hpb.2015.09.006] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Accepted: 09/27/2015] [Indexed: 12/12/2022]
Abstract
BACKGROUND Gallbladder adenomyomatosis (GA) is a benign gallbladder entity discovered as an asymptomatic gallbladder mass. Since gallbladder cancer is in the differential diagnosis for gallbladder masses, the ability to differentiate benign disease avoids a more extensive oncologic resection. This study sought to review imaging modalities used to diagnose GA. METHODS PubMed and SciVerse Scopus were systematically searched using the terms: "gallbladder adenomyomatosis" and "gallbladder imaging" for articles published between January 2000 and January 2015. RESULTS A total of 14 articles were reviewed in this analysis. Contemporary series report the use of ultrasound (US), computed tomography (CT) or magnetic resonance imaging (MRI) in GA imaging. Ultrasound detection of Rokitansky-Aschoff sinuses, visualized as small cystic spaces with associated "comet-tail" or "twinkling" artifact, is pathognomonic for GA. A "Pearl-Necklace" sign of small connected sinuses on MRI or "Rosary" sign on CT are additional characteristics that may assist in establishing a diagnosis. CONCLUSION Ultrasound is the most commonly used tool to investigate GA. If not diagnostic, CT or MRI are effective in attempting to differentiate a benign or malignant cholecystic mass. Characteristic signs should lead the surgeon to perform a laparoscopic cholecystectomy in symptomatic patients or manage non-operatively in asymptomatic patients.
Collapse
Affiliation(s)
- Abdulrahman Y. Hammad
- Division of Surgical Oncology, Department of Surgery, Medical College of Wisconsin, Milwaukee, WI, USA
| | - John T. Miura
- Division of Surgical Oncology, Department of Surgery, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Kiran K. Turaga
- Division of Surgical Oncology, Department of Surgery, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Fabian M. Johnston
- Division of Surgical Oncology, Department of Surgery, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Mark D. Hohenwalter
- Section of Abdominal Imaging, Division of Diagnostic Radiology, Department of Radiology, Medical College of Wisconsin, Milwaukee, WI, USA
| | - T. Clark Gamblin
- Division of Surgical Oncology, Department of Surgery, Medical College of Wisconsin, Milwaukee, WI, USA,Correspondence T. Clark Gamblin, Division of Surgical Oncology, Department of Surgery, Medical College of Wisconsin, 9200 West Wisconsin Ave, Milwaukee, WI 53226, USA. Tel: +1 414 805 5020. Fax: +1 414 805 5771.
| |
Collapse
|
40
|
Bhatt NR, Gillis A, Smoothey CO, Awan FN, Ridgway PF. Evidence based management of polyps of the gall bladder: A systematic review of the risk factors of malignancy. Surgeon 2016; 14:278-86. [PMID: 26825588 DOI: 10.1016/j.surge.2015.12.001] [Citation(s) in RCA: 59] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2015] [Revised: 11/29/2015] [Accepted: 12/04/2015] [Indexed: 12/25/2022]
Abstract
BACKGROUND There are no evidence-based guidelines to dictate when Gallbladder Polyps (GBPs) of varying sizes should be resected. AIM To identify factors that accurately predict malignant disease in GBP; to provide an evidence-based algorithm for management. METHODS A systematic review following PRISMA guidelines was performed using terms "gallbladder polyps" AND "polypoid lesion of gallbladder", from January 1993 and September 2013. Inclusion criteria required histopathological report or follow-up of 2 years. RTI-IB tool was used for quality analysis. Correlation with GBP size and malignant potential was analysed using Euclidean distance; a logistics mixed effects model was used for assessing independent risk factors for malignancy. RESULTS Fifty-three articles were included in review. Data from 21 studies was pooled for analysis. Optimum size cut-off for resection of GBPs was 10 mm. Probability of malignancy is approximately zero at size <4.15 mm. Patient age >50 years, sessile and single polyps were independent risk factors for malignancy. For polyps sized 4 mm-10 mm, a risk assessment model was formulated. CONCLUSIONS This review and analysis has provided an evidence-based algorithm for the management of GBPs. Longitudinal studies are needed to better understand the behaviour of polyps <10 mm, that are not at a high risk of malignancy, but may change over time.
Collapse
Affiliation(s)
- Nikita R Bhatt
- Department of Surgery, University of Dublin, Trinity College, at the Adelaide and Meath Hospital, Tallaght, Dublin, Ireland
| | - Amy Gillis
- Department of Surgery, University of Dublin, Trinity College, at the Adelaide and Meath Hospital, Tallaght, Dublin, Ireland
| | - Craig O Smoothey
- School of Mechanical and Materials Engineering, University College Dublin, Ireland
| | - Faisal N Awan
- Department of Hepatobiliary Surgery, St. Vincent's University Hospital, Dublin, Ireland
| | - Paul F Ridgway
- Department of Surgery, University of Dublin, Trinity College, at the Adelaide and Meath Hospital, Tallaght, Dublin, Ireland.
| |
Collapse
|
41
|
Tang S, Huang L, Wang Y, Wang Y. Contrast-enhanced ultrasonography diagnosis of fundal localized type of gallbladder adenomyomatosis. BMC Gastroenterol. 2015;15:99. [PMID: 26239485 PMCID: PMC4524444 DOI: 10.1186/s12876-015-0326-y] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2015] [Accepted: 07/27/2015] [Indexed: 12/15/2022] Open
Abstract
Background Adenomyomatosis of gallbladder is an acquired hyperplastic lesion, characterized by focal or diffuse thickening of the gallbladder with intramural cysts or echogenic areas with comet tail on ultrasonography. But in some cases, especially in the localized fundal type of adenomyomatosis, the intramural anechoic cystic spaces are uncertainty which causes difficult to differential adenomyomatosis from GB cancer. The purpose of this study was to determine the accuracy of real-time contrast-enhanced ultrasonography(CEUS) in the diagnosis of the fundal localized type of gallbladder adenomyomatosis. Methods We performed a retrospective study of 21 patients with pathologically proven fundal localized type of gallbladder (GB) adenomyomatosis. All patients underwent preoperative grayscale ultrasound (US) and real-time CEUS examination. The study’s reviewers made the diagnosis of adenomyomatosis according to the presence of the focal thickening of the fundal gallbladder wall with intramural cyst or intramural echogenic foci on grayscale US or CEUS. The diagnostic accuracy of US and CEUS was compared. The enhanced pattern and degree of intactness of the GB wall were also recorded. Results The fundal portion of the GB wall showed localized thickness in all 21 patients. Small anechoic spaces or intramural echogenic foci were detected in 14 (66.7 %) and 21 (100 %) of cases respectively, and the intactness of the GB wall’s outer hyper-echoic layer was demonstrated in 17 (81 %) and 20 (95 %) on grayscale US and CEUS, respectively. The accuracy rate of the above two examination modalities was significantly different (p < 0.05). In the arterial phase of the CEUS, areas of focal thickened GB wall were iso-enhanced in 18 cases and hyper-enhanced in 3 cases. All 21 cases appeared to show heterogeneous enhancement with small non-enhancement spaces. The mucosal and serosal layers of the GB wall surrounding the lesions were enhanced, which presented as two “hyper-echoic lines” in the arterial phase of CEUS. In the venous phase of the CEUS, 19 lesions were iso-enhanced and 2 lesions were hypo-enhanced. The small non-enhancement spaces were more clearly during the venous phase. Conclusion The small non-enhancement space is a characteristic finding of the fundal localized type of gallbladder adenomyomatosis on CEUS. CEUS could increase the degree of visualization of Rokitansky-Aschoff sinuses (RAS) and intactness of the GB wall, which play an important role in differential diagnosis.
Collapse
|
42
|
Babu BI, Dennison AR, Garcea G. Management and diagnosis of gallbladder polyps: a systematic review. Langenbecks Arch Surg 2015; 400:455-62. [PMID: 25910600 DOI: 10.1007/s00423-015-1302-2] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2014] [Accepted: 04/13/2015] [Indexed: 12/14/2022]
Abstract
PURPOSE Recommendation for management of gallbladder polyps (GBPs) >1 cm is cholecystectomy. No consensus exists on management of GBPs <1 cm. This systematic review examines current evidence on management of GBPs. METHODS MEDLINE, EMBASE and Cochrane library databases were searched from January 1991 to June 2013 using specified terms. A predefined protocol for data extraction was used to retrieve specified end points. RESULTS Literature search yielded 43 manuscripts with a dataset of 11,685 patients with GBPs. M:F ratio was 1.3:1. Average age (range) was 49 years (32-83). Patients with malignant GBPs had an average (range) age of 58 (50-66) years with M:F ratio of 0.78:1. Cholesterol polyps constituted 60.5% of GBPs followed by adenomas (15.2%) and cancer (11.6%). Malignant GBPs ≥1 cm, <1 cm and <5 mm constituted 8.5, 1.2 and 0% of GBPs, respectively. Majority of patients requiring surgical intervention had laparoscopic cholecystectomy. CONCLUSIONS Presently employed policy of cholecystectomy for GBPs >1 cm is appropriate. For GBPs <1 cm, the authors propose (accepting existence of differing proposals) the following: 1. Surveillance may not be needed for GBPs <5 mm. 2. For GBPs between 5 and 10 mm, two scans at six monthly intervals is suggested and after that, tailor surveillance to age, growth and ethnicity. In the non-Asian population, if GBP remains the same size or number, discontinuation of surveillance may be considered. In the Asian population, if GBPs remain the same, yearly surveillance is continued for a suggested period of 3 years. 3. Discontinue surveillance if GBPs is/are smaller/ disappeared. Cholecystectomy is advised where size increases to >10 mm.
Collapse
Affiliation(s)
- Benoy I Babu
- Leicester HPB Unit, University Hospitals of Leicester, Gwendolen Road, LE5 4PW, Leicester, UK,
| | | | | |
Collapse
|
43
|
Teoh AYB, Tang RSY. Clinical evaluation of new diagnostic modalities of endoscopic ultrasound for pancreaticobiliary diseases. Dig Endosc 2015; 27 Suppl 1:55-9. [PMID: 25645516 DOI: 10.1111/den.12444] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2014] [Accepted: 01/19/2015] [Indexed: 12/19/2022]
Abstract
Endoscopic ultrasonography (EUS) is currently an integral tool for work-up of pancreaticobiliary neoplasms. Tissue acquisition by EUS is possible with fine-needle aspiration (FNA) cytology and histology. However, FNA still carries some limitations and risks of complications. The use of image-enhanced EUS may improve detection and characterization of pancreaticobiliary neoplasms and complement FNA. The present article aims to provide an overview of the current development of contrast-enhanced imaging and elastography in EUS and their potential application in the diagnosis of pancreaticobiliary diseases.
Collapse
|
44
|
Kitano M, Kamata K, Imai H, Miyata T, Yasukawa S, Yanagisawa A, Kudo M. Contrast-enhanced harmonic endoscopic ultrasonography for pancreatobiliary diseases. Dig Endosc 2015; 27 Suppl 1:60-7. [PMID: 25639788 DOI: 10.1111/den.12454] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2014] [Accepted: 01/27/2015] [Indexed: 02/08/2023]
Abstract
The combination of second-generation ultrasound contrast agents and an endoscopic ultrasonography (EUS) system with a broad-band transducer has allowed contrast-enhanced harmonic imaging in the field of EUS. In contrast-enhanced harmonic EUS (CH-EUS), diffuse homogeneous enhancement is obtained in normal parenchyma of the pancreas. The bile duct and pancreatic duct are depicted as non-enhanced ductal structures with strong contrast in comparison to the surrounding parenchyma. CH-EUS identifies pancreatic adenocarcinomas as solid lesions exhibiting hypo-enhancement with a sensitivity and specificity of 88-96% and 88-94%, respectively. In particular, 80-100% of false-negative cases in endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) are correctly classified by CH-EUS, suggesting CH-EUS complements EUS-FNA. Moreover, CH-EUS improves depiction of some subtle lesions in conventional EUS, thus facilitating EUS-FNA. For quantitative perfusion analysis, a time-intensity curve (TIC) for the region of interest can be generated during CH-EUS. The maximum intensity gain and the echo intensity reduction rate from the peak at 1 min obtained by TIC can be used for differentiation of pancreatic adenocarcinoma from other tumors. CH-EUS is also useful for differentiation of invasive intraductal papillary mucinous neoplasms (IPMN) from non-invasive IPMN, identification of malignant lesions in the gallbladder, and T- and N-staging of pancreatobiliary tumors.
Collapse
Affiliation(s)
- Masayuki Kitano
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka, Japan
| | | | | | | | | | | | | |
Collapse
|
45
|
Abstract
BACKGROUND Gallbladder adenoma is a pre-cancerous neoplasm and needs surgical resection. It is difficult to differentiate adenoma from other gallbladder polyps using imaging examinations. The study aimed to illustrate characteristics of contrast-enhanced ultrasound (CEUS) and its diagnostic value in gallbladder adenoma. METHODS Thirty-seven patients with 39 gallbladder adenomatoid lesions (maximal diameter ≥10 mm and without metastasis) were enrolled in this study. Lesion appearances in conventional ultrasound and CEUS were documented. The imaging features were compared individually among gallbladder cholesterol polyp, gallbladder adenoma and malignant lesion. RESULTS Adenoma lesions showed iso-echogenicity in ultrasound, and an eccentric enhancement pattern, "fast-in and synchronous-out" contrast enhancement pattern and homogeneous at peak-time enhancement in CEUS. The homogenicity at peak-time enhancement showed the highest diagnostic ability in differentiating gallbladder adenoma from cholesterol polyps. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy and Youden index were 100%, 90.9%, 92.9%, 100%, 95.8% and 0.91, respectively. The characteristic of continuous gallbladder wall shown by CEUS had the highest diagnostic ability in differentiating adenoma from malignant lesion (100%, 86.7%, 86.7%, 100%, 92.9% and 0.87, respectively). The characteristic of the eccentric enhancement pattern had the highest diagnostic ability in differentiating adenoma from cholesterol polyp and malignant lesion, with corresponding indices of 69.2%, 88.5%, 75.0%, 85.2%, 82.1% and 0.58, respectively. CONCLUSIONS CEUS is valuable in differentiating gallbladder adenoma from other gallbladder polyps (≥10 mm in diameter). Homogeneous echogenicity on peak-time enhancement, a continuous gallbladder wall, and the eccentric enhancement pattern are important indicators of gallbladder adenoma on CEUS.
Collapse
Affiliation(s)
- Hai-Xia Yuan
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China.
| | | | | | | | | | | |
Collapse
|
46
|
Hammoud GM, Almashhrawi A, Ibdah JA. Usefulness of endoscopic ultrasound-guided fine needle aspiration in the diagnosis of hepatic, gallbladder and biliary tract Lesions. World J Gastrointest Oncol 2014; 6:420-429. [PMID: 25400873 PMCID: PMC4229785 DOI: 10.4251/wjgo.v6.i11.420] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Revised: 09/17/2014] [Accepted: 10/27/2014] [Indexed: 02/05/2023] Open
Abstract
Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) of the liver is a safe procedure in the diagnosis and staging of hepatobiliary malignancies with a minimal major complication rate. EUS-FNA is useful for liver lesions poorly accessible to other imaging modalities of the liver. EUS-guided FNA of biliary neoplasia and malignant biliary stricture is superior to the conventional endoscopic brushing and biopsy.
Collapse
|
47
|
Alvarez-Sánchez MV, Napoléon B. Contrast-enhanced harmonic endoscopic ultrasound imaging: Basic principles, present situation and future perspectives. World J Gastroenterol 2014; 20:15549-15563. [PMID: 25400439 PMCID: PMC4229520 DOI: 10.3748/wjg.v20.i42.15549] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2013] [Revised: 04/23/2014] [Accepted: 05/19/2014] [Indexed: 02/06/2023] Open
Abstract
Over the last decade, the development of stabilised microbubble contrast agents and improvements in available ultrasonic equipment, such as harmonic imaging, have enabled us to display microbubble enhancements on a greyscale with optimal contrast and spatial resolution. Recent technological advances made contrast harmonic technology available for endoscopic ultrasound (EUS) for the first time in 2008. Thus, the evaluation of microcirculation is now feasible with EUS, prompting the evolution of contrast-enhanced EUS from vascular imaging to images of the perfused tissue. Although the relevant experience is still preliminary, several reports have highlighted contrast-enhanced harmonic EUS (CH-EUS) as a promising noninvasive method to visualise and characterise lesions and to differentiate benign from malignant focal lesions. Even if histology remains the gold standard, the combination of CH-EUS and EUS fine needle aspiration (EUS-FNA) can not only render EUS more accurate but may also assist physicians in making decisions when EUS-FNA is inconclusive, increasing the yield of EUS-FNA by guiding the puncture with simultaneous imaging of the vascularity. The development of CH-EUS has also opened up exciting possibilities in other research areas, including monitoring responses to anticancer chemotherapy or to ethanol-induced pancreatic tissue ablation, anticancer therapies based on ultrasound-triggered drug and gene delivery, and therapeutic adjuvants by contrast ultrasound-induced apoptosis. Contrast harmonic imaging is gaining popularity because of its efficacy, simplicity and non-invasive nature, and many expectations are currently resting on this technique. If its potential is confirmed in the near future, contrast harmonic imaging will become a standard practice in EUS.
Collapse
|
48
|
Morris-Stiff G, Farid S. When to CHEUS contrast-enhanced endoscopic ultrasound to assess gallbladder wall thickening. Dig Dis Sci 2014; 59:1679-80. [PMID: 24906698 DOI: 10.1007/s10620-014-3241-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2014] [Accepted: 05/29/2014] [Indexed: 12/09/2022]
Affiliation(s)
- Gareth Morris-Stiff
- Division of Hepato-Pancreato-Biliary Surgery, Department of General Surgery, A100 Cleveland Clinic Foundation, Cleveland, OH, 44195, USA,
| | | |
Collapse
|
49
|
Ogura T, Kurisu Y, Masuda D, Imoto A, Onda S, Kamiyama R, Hayashi M, Mohamed M, Uchiyama K, Higuchi K. Can endoscopic ultrasound-guided fine needle aspiration offer clinical benefit for thick-walled gallbladders? Dig Dis Sci 2014; 59:1917-24. [PMID: 24615550 DOI: 10.1007/s10620-014-3100-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2013] [Accepted: 02/26/2014] [Indexed: 02/07/2023]
Abstract
BACKGROUND No previous studies have compared cytology obtained under endoscopic transpapillary gallbladder drainage (ETGD) and EUS-guided fine needle aspiration (EUS-FNA) for thick-walled gallbladders. AIM The present study investigated the diagnostic yield of bile cytology under ETGD and EUS-FNA for gallbladder tumors. METHODS A total of 69 patients were diagnosed as having gallbladder wall thickening. Among these patients, 28 patients were diagnosed by clinical follow-up, solely by imaging such as computed tomography or by histological examination of surgical specimens. The remaining 41 patients underwent ETGD and/or EUS-FNA. In these 41 patients, the clinical data collected included gender, age, diameter of gallbladder wall, site of gallbladder wall thickening, final diagnosis, adverse events, and diagnostic yield of ETGD and EUS-FNA. RESULTS Cyto-histological diagnosis with EUS-FNA was higher than that with ETGD, with a sensitivity of 100 versus 71%, specificity of 100 versus 94%, and accuracy of 100 versus 88%, respectively, in the two groups. In addition, the sampling adequacy of EUS-FNA was 100%. Adverse events were seen in five patients in the ETGD group (mild pancreatitis), although no adverse events were seen in the EUS-FNA group (P = 0.08). CONCLUSION Our results suggest that EUS-FNA can be safely performed for the diagnosis of gallbladder lesions. Further, this procedure may be the diagnostic method of choice over cytology of bile juice obtained via ETGD to obtain histological evidence of gallbladder cancer.
Collapse
|
50
|
Imazu H, Mori N, Kanazawa K, Chiba M, Toyoizumi H, Torisu Y, Koyama S, Hino S, Ang TL, Tajiri H. Contrast-enhanced harmonic endoscopic ultrasonography in the differential diagnosis of gallbladder wall thickening. Dig Dis Sci 2014; 59:1909-16. [PMID: 24664415 DOI: 10.1007/s10620-014-3115-5] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2014] [Accepted: 03/12/2014] [Indexed: 01/01/2023]
Abstract
BACKGROUND AND AIMS Differentiation of gallbladder (GB) carcinoma from benign GB wall thickening is challenging. The recent introduction of second-generation ultrasonic contrast agents has made contrast harmonic imaging with EUS possible. The aim of our study was to evaluate the utility of contrast-enhanced harmonic EUS (CH-EUS) for the differential diagnosis of GB wall thickening. METHODS Thirty-six consecutive patients with GB wall thickening imaged by CH-EUS and then underwent surgery were enrolled in this study. After the lesions were observed with conventional harmonic EUS (H-EUS), CH-EUS was performed with intravenous injection of 0.015 ml/kg of Sonazoid. Three reviewers with various levels of experience of EUS (Reviewer A: experienced endosonographer, B: EUS trainee, C: experienced gastroenterologist with expertise in transabdominal ultrasound but no EUS experience) were blinded to findings of recorded video of H-EUS and CH-EUS. The diagnostic accuracy of H-EUS and CH-EUS for malignant GB wall thickening was compared. RESULTS Final diagnoses based on surgical histology were GB carcinoma in 16, cholecystitis in 11, adenomyomatosis in 6 and cholesterolosis in 3. Overall sensitivity, specificity and accuracy for diagnosing malignant GB wall thickening of H-EUS and CH-EUS were 83.3 versus 89.6, 65 versus 98% (p < 0.001) and 73.1 versus 94.4% (p < 0.001). The inter-observer agreement for H-EUS was moderate (κ = 0.51), whereas that for CH-EUS was substantial (κ = 0.77). The inhomogeneous enhanced pattern on CH-EUS was a strong predictive factor of malignant GB wall thickening. CONCLUSION CH-EUS has the potential to improve the preoperative diagnostic accuracy and inter-observer agreement in the differential diagnosis of GB wall thickening.
Collapse
Affiliation(s)
- Hiroo Imazu
- Department of Endoscopy, The Jikei University School of Medicine, 3-25-8 Nishishinbashi, Minato-ku, Tokyo, 105-8461, Japan,
| | | | | | | | | | | | | | | | | | | |
Collapse
|