Hess R, Faessler J, Yun D, Mama A, Saleh D, Grosch JH, Wang G, Schwab T, Hubbuch J. Predicting multimodal chromatography of therapeutic antibodies using multiscale modeling. J Chromatogr A 2024; 1718:464706. [PMID: 38335881 DOI: 10.1016/j.chroma.2024.464706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Revised: 01/30/2024] [Accepted: 01/31/2024] [Indexed: 02/12/2024]
Abstract
Multimodal chromatography has emerged as a powerful method for the purification of therapeutic antibodies. However, process development of this separation technique remains challenging because of an intricate and molecule-specific interaction towards multimodal ligands, leading to time-consuming and costly experimental optimization. This study presents a multiscale modeling approach to predict the multimodal chromatographic behavior of therapeutic antibodies based on their sequence information. Linear gradient elution (LGE) experiments were performed on an anionic multimodal resin for 59 full-length antibodies, including five different antibody formats at pH 5.0, 6.0, and 7.0 that were used for parameter determination of a linear adsorption model at low loading density conditions. Quantitative structure-property relationship (QSPR) modeling was utilized to correlate the adsorption parameters with up to 1374 global and local physicochemical descriptors calculated from antibody homology models. The final QSPR models employed less than eight descriptors per model and demonstrated high training accuracy (R² > 0.93) and reasonable test set prediction accuracy (Q² > 0.83) for the adsorption parameters. Model evaluation revealed the significance of electrostatic interaction and hydrophobicity in determining the chromatographic behavior of antibodies, as well as the importance of the HFR3 region in antibody binding to the multimodal resin. Chromatographic simulations using the predicted adsorption parameters showed good agreement with the experimental data for the vast majority of antibodies not employed during the model training. The results of this study demonstrate the potential of sequence-based prediction for determining chromatographic behavior in therapeutic antibody purification. This approach leads to more efficient and cost-effective process development, providing a valuable tool for the biopharmaceutical industry.
Collapse
Affiliation(s)
- Rudger Hess
- Karlsruhe Institute of Technology (KIT), Institute of Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe, Germany; DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jan Faessler
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Doil Yun
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Ahmed Mama
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - David Saleh
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jan-Hendrik Grosch
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Gang Wang
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Thomas Schwab
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jürgen Hubbuch
- Karlsruhe Institute of Technology (KIT), Institute of Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe, Germany.
| |
Collapse
|
2
|
Yang YX, Chen YC, Yao SJ, Lin DQ. Parameter-by-parameter estimation method for adsorption isotherm in hydrophobic interaction chromatography. J Chromatogr A 2024; 1716:464638. [PMID: 38219627 DOI: 10.1016/j.chroma.2024.464638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 01/06/2024] [Accepted: 01/08/2024] [Indexed: 01/16/2024]
Abstract
Hydrophobic interaction chromatography (HIC) is used as a critical polishing step in the downstream processing of biopharmaceuticals. Normally the process development of HIC is a cumbersome and time-consuming task, and the mechanical models can provide a powerful tool to characterize the process, assist process design and accelerate process development. However, the current estimation of model parameters relies on the inverse method, which lacks an efficient and logical parameter estimation strategy. In this study, a parameter-by-parameter (PbP) method based on the theoretical derivation and simplifying assumptions was proposed to estimate the Mollerup isotherm parameters for HIC. The method involves three key steps: (1) linear regression (LR) to estimate the salt-protein interaction parameter and the equilibrium constant; (2) linear approximation (LA) to estimate the stoichiometric parameter and the maximum binding capacity; and (3) inverse method to estimate the protein-protein interaction parameter and the kinetic coefficient. The results indicated that the LR step should be used for dilution condition (loading factor below 5%), while the LA step should be conducted when the isotherm is in the transition or nonlinear regions. Six numerical experiments were conducted to implement the PbP method. The results demonstrated that the PbP method developed allows for the systematic estimation of HIC parameters one-by-one, effectively reducing the number of parameters required for inverse method estimation from six to two. This helps prevent non-identifiability of structural parameters. The feasibility of the PbP-HIC method was further validated by real-world experiments. Moreover, the PbP method enhances the mechanistic understanding of adsorption behavior of HIC and shows a promising application to other stoichiometric displacement model-derived isotherms.
Collapse
Affiliation(s)
- Yu-Xiang Yang
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Yu-Cheng Chen
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Shan-Jing Yao
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Dong-Qiang Lin
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
3
|
Hess R, Faessler J, Yun D, Saleh D, Grosch JH, Schwab T, Hubbuch J. Antibody sequence-based prediction of pH gradient elution in multimodal chromatography. J Chromatogr A 2023; 1711:464437. [PMID: 37865026 DOI: 10.1016/j.chroma.2023.464437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 10/03/2023] [Accepted: 10/05/2023] [Indexed: 10/23/2023]
Abstract
Multimodal chromatography has emerged as a promising technique for antibody purification, owing to its capacity to selectively capture and separate target molecules. However, the optimization of chromatography parameters remains a challenge due to the intricate nature of protein-ligand interactions. To tackle this issue, efficient predictive tools are essential for the development and optimization of multimodal chromatography processes. In this study, we introduce a methodology that predicts the elution behavior of antibodies in multimodal chromatography based on their amino acid sequences. We analyzed a total of 64 full-length antibodies, including IgG1, IgG4, and IgG-like multispecific formats, which were eluted using linear pH gradients from pH 9.0 to 4.0 on the anionic mixed-mode resin Capto adhere. Homology models were constructed, and 1312 antibody-specific physicochemical descriptors were calculated for each molecule. Our analysis identified six key structural features of the multimodal antibody interaction, which were correlated with the elution behavior, emphasizing the antibody variable region. The results show that our methodology can predict pH gradient elution for a diverse range of antibodies and antibody formats, with a test set R² of 0.898. The developed model can inform process development by predicting initial conditions for multimodal elution, thereby reducing trial and error during process optimization. Furthermore, the model holds the potential to enable an in silico manufacturability assessment by screening target antibodies that adhere to standardized purification conditions. In conclusion, this study highlights the feasibility of using structure-based prediction to enhance antibody purification in the biopharmaceutical industry. This approach can lead to more efficient and cost-effective process development while increasing process understanding.
Collapse
Affiliation(s)
- Rudger Hess
- Institute of Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany; DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jan Faessler
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Doil Yun
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - David Saleh
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jan-Hendrik Grosch
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Thomas Schwab
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jürgen Hubbuch
- Institute of Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.
| |
Collapse
|
4
|
Lorek JK, Karkov HS, Matthiesen F, Dainiak M. High throughput screening for rapid and reliable prediction of monovalent antibody binding behavior in flowthrough mode. Biotechnol Bioeng 2023. [PMID: 37926999 DOI: 10.1002/bit.28572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 09/11/2023] [Accepted: 09/21/2023] [Indexed: 11/07/2023]
Abstract
Flowthrough (FT) anion exchange (AEX) chromatography is a widely used polishing step for the purification of monoclonal antibody (mAb) formats. To accelerate downstream process development, high throughput screening (HTS) tools have proven useful. In this study, the binding behavior of six monovalent mAbs (mvAbs) was investigated by HTS in batch binding mode on different AEX and mixed-mode resins at process-relevant pH and NaCl concentrations. The HTS entailed the evaluation of mvAb partition coefficients (Kp ) and visualization of results in surface-response models. Interestingly, the HTS data grouped the mvAbs into either a strong-binding group or a weak-binding/FT group independent of theoretical Isoelectric point. Mapping the charged and hydrophobic patches by in silico protein surface property analyses revealed that the distribution of patches play a major role in predicting FT behavior. Importantly, the conditions identified by HTS were successfully verified by 1 mL on-column experiments. Finally, employing the optimal FT conditions (7-9 mS/cm and pH 7.0) at a mini-pilot scale (CV = 259 mL) resulted in 99% yield and a 21-23-fold reduction of host cell protein to <100 ppm, depending on the varying host cell protein (HCP) levels in the load. This work opens the possibility of using HTS in FT mode to accelerate downstream process development for mvAb candidates in early research.
Collapse
Affiliation(s)
| | | | - Finn Matthiesen
- Purification Technologies, Novo Nordisk A/S, Maaloev, Denmark
| | - Maria Dainiak
- Purification Technologies, Novo Nordisk A/S, Maaloev, Denmark
| |
Collapse
|
5
|
Altern SH, Welsh JP, Lyall JY, Kocot AJ, Burgess S, Kumar V, Williams C, Lenhoff AM, Cramer SM. Isotherm model discrimination for multimodal chromatography using mechanistic models derived from high-throughput batch isotherm data. J Chromatogr A 2023; 1693:463878. [PMID: 36827799 DOI: 10.1016/j.chroma.2023.463878] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2022] [Revised: 02/05/2023] [Accepted: 02/15/2023] [Indexed: 02/19/2023]
Abstract
In this work, we have examined an array of isotherm formalisms and characterized them based on their relative complexities and predictive abilities with multimodal chromatography. The set of isotherm models studied were all based on the stoichiometric displacement framework, with considerations for electrostatic interactions, hydrophobic interactions, and thermodynamic activities. Isotherm parameters for each model were first determined through twenty repeated fits to a set of mAb - Capto MMC batch isotherm data spanning a range of loading, ionic strength, and pH as well as a set of mAb - Capto Adhere batch data at constant pH. The batch isotherm data were used in two ways-spanning the full range of loading or consisting of only the high concentration data points. Predictive ability was defined through the model's capacity to capture prominent changes in salt gradient elution behavior with respect to pH for Capto MMC or unique elution patterns and yield losses with respect to gradient slope for Capto Adhere. In both cases, model performance was quantified using a scoring metric based on agreement in peak characteristics for column predictions and accuracy of fit for the batch data. These scores were evaluated for all twenty isotherm fits and their corresponding column predictions, thereby producing a statistical distribution of model performances. Model complexity (number of isotherm parameters) was then considered through use of the Akaike information criterion (AIC) calculated from the score distributions. While model performance for Capto MMC benefitted substantially from removal of low protein concentration data, this was not the case for Capto Adhere; this difference was likely due to the qualitatively different shapes of the isotherms between the two resins. Surprisingly, the top-performing (high accuracy with minimal number of parameters) isotherm model was the same for both resins. The extended steric mass action (SMA) isotherm (containing both protein-salt and protein-protein activity terms) accurately captured both the pH-dependent elution behavior for Capto MMC as well as loss in protein recovery with increasing gradient slope for Capto Adhere. In addition, this isotherm model achieved the highest median score in both resin systems, despite it lacking any explicit hydrophobic stoichiometric terms. The more complex isotherm models, which explicitly accounted for both electrostatic and hydrophobic interaction stoichiometries, were ill-suited for Capto MMC and had lower AIC model likelihoods for Capto Adhere due to their increased complexity. Interestingly, the ability of the extended SMA isotherm to predict the Capto Adhere results was largely due to the protein-salt activity coefficient, as determined via isotherm parameter sensitivity analyses. Further, parametric studies on this parameter demonstrated that it had a major impact on both binding affinity and elution behavior, therein fully capturing the impact of hydrophobic interactions. In summary, we were able to determine the isotherm formalisms most capable of consistently predicting a wide range of column behavior for both a multimodal cation-exchange and multimodal anion-exchange resin with high accuracy, while containing a minimized set of model parameters.
Collapse
Affiliation(s)
- Scott H Altern
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - John P Welsh
- Biologics Process Research and Development, Merck & Co., Inc., Rahway, NJ, USA
| | - Jessica Y Lyall
- Purification Development, Genentech, South San Francisco, CA, USA
| | - Andrew J Kocot
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Sean Burgess
- Purification Development, Genentech, South San Francisco, CA, USA
| | - Vijesh Kumar
- Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA
| | - Chris Williams
- Purification Development, Genentech, South San Francisco, CA, USA
| | - Abraham M Lenhoff
- Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA
| | - Steven M Cramer
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA.
| |
Collapse
|