Takaseya T, Itaya N, Sasaki KI, Sasaki M, Yokomizo M, Honda A, Oshita K, Azuma J, Fukumoto Y, Tayama E. Cusp overlap technique decreases paravalvular leakage in self-expandable transcatheter aortic valve replacement. Heart Vessels 2024; 39:48-56. [PMID: 37606754 DOI: 10.1007/s00380-023-02307-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Accepted: 08/16/2023] [Indexed: 08/23/2023]
Abstract
The cusp overlap technique allows greater visual separation between the basal annular plane and the conduction system and decreases the permanent pacemaker implantation rate. We assessed the impact of the cusp overlap technique on conduction disturbance and paravalvular leakage after transcatheter aortic valve replacement. A total of 97 patients underwent transfemoral transcatheter aortic valve replacement with self-expandable valves at our institution from November 2018 to January 2023. The mean age of the patients was 85 years, and 23% were male. The patients were divided into two groups: the cusp overlap technique group and the non-cusp overlap technique group. We compared the clinical results between the two groups. The 30-day permanent pacemaker implantation rate was similar between the two groups (cusp overlap technique: 6.3% vs. non-cusp overlap technique: 10.2%, p = 0.48). The rate of new-onset conduction disturbance was slightly lower in the cusp overlap than non-cusp overlap technique group (18.8% vs. 34.7%, respectively; p = 0.08). The implanted valve function was similar between the two groups, but the rate of trivial or less paravalvular leakage (PVL) was significantly higher in the cusp overlap technique group on echocardiography (69% vs. 45%, p = 0.02). On multidetector computed tomography, the implantation depth at the membranous septum was significantly shorter in the cusp overlap technique group (2.0 ± 2.3 vs. 2.9 ± 1.5 mm, p = 0.02). The degree of canting was slightly smaller in the cusp overlap technique group (1.0 ± 2.2 vs. 1.7 ± 1.9 mm, p = 0.07). The relative risk of PVL equal to or greater than mild was 1.76 times higher for valve implantation without the cusp overlap technique (adjusted odds ratio, 3.74; 95% confidence interval, 1.45-9.69; p < 0.01). Transcatheter aortic valve replacement using the cusp overlap technique is associated with an optimized implantation depth, leading to fewer conduction disturbances. Optimal deployment may also maximize the radial force of self-expanding valves to reduce paravalvular leakage.
Collapse
Affiliation(s)
- Tohru Takaseya
- Division of Cardiovascular Surgery, Department of Surgery, Kurume University School of Medicine, 67 Asahi-Machi, Kurume-Shi, Fukuoka, 830-0011, Japan.
| | - Naoki Itaya
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kurume University School of Medicine, Kurume-Shi, Fukuoka, 830-0011, Japan
| | - Ken-Ichiro Sasaki
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kurume University School of Medicine, Kurume-Shi, Fukuoka, 830-0011, Japan
| | - Masahiro Sasaki
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kurume University School of Medicine, Kurume-Shi, Fukuoka, 830-0011, Japan
| | - Michiko Yokomizo
- Department of Anesthesiology, Kurume University School of Medicine, Kurume-Shi, Fukuoka, 830-0011, Japan
| | - Akihiro Honda
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kurume University School of Medicine, Kurume-Shi, Fukuoka, 830-0011, Japan
| | - Kensuke Oshita
- Department of Anesthesiology, Kurume University School of Medicine, Kurume-Shi, Fukuoka, 830-0011, Japan
| | - Junpei Azuma
- Division of Radiology, Kurume University Hospital, Kurume-Shi, Fukuoka, 830-0011, Japan
| | - Yoshihiro Fukumoto
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kurume University School of Medicine, Kurume-Shi, Fukuoka, 830-0011, Japan
| | - Eiki Tayama
- Division of Cardiovascular Surgery, Department of Surgery, Kurume University School of Medicine, 67 Asahi-Machi, Kurume-Shi, Fukuoka, 830-0011, Japan
| |
Collapse
|
2
|
Gutierrez L, Boiago M, De Biase C, Oliva O, Laforgia P, Feliachi S, Beneduce A, Dumonteil N, Tchetche D. Transcatheter Aortic Valve Implantation for Bicuspid Aortic Valve Disease: Procedural Planning and Clinical Outcomes. J Clin Med 2023; 12:7074. [PMID: 38002687 PMCID: PMC10672483 DOI: 10.3390/jcm12227074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 10/15/2023] [Accepted: 10/24/2023] [Indexed: 11/26/2023] Open
Abstract
Bicuspid aortic valve (BAV) is the most common congenital heart disease, with a prevalence of 1-2% and occurring in >20% of octogenarians referred for aortic valve replacement. However, BAV patients have been systematically excluded from pivotal randomized trials. Since TAVI indications are moving toward low-risk patients, an increase in the number of BAV patients who undergo TAVI is expected. BAV represents a challenge due to its unique morphological features (raphe, extreme asymmetrical valve calcifications, cusp asymmetry and aortopathy) and the lack of consensus about the accurate sizing method. The role of multi-slice computed tomography (MSCT) in the planification of the TAVI procedure is well-established, being useful to define the optimal valve sizing and the implantation strategy. New-generation devices, more experience of the operators and better planification of the procedure have been associated with similar clinical outcomes in bicuspid and tricuspid patients undergoing TAVI.
Collapse
Affiliation(s)
- Lola Gutierrez
- Groupe Cardiovasculaire Interventionnel (GCVI), Clinique Pasteur, 31300 Toulouse, France; (M.B.); (C.D.B.); (O.O.); (P.L.); (S.F.); (A.B.); (N.D.); (D.T.)
| | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Moura AR, Rodrigues JA, Braga P, Melica B, Santos L, Pires-Morais G, Sampaio F, Fontes-Carvalho R. Impact of the use of cusp-overlap projection on the incidence of permanent pacemaker implantation post-transcatheter aortic valve implantation with self-expanding valves. Rev Port Cardiol 2023; 42:759-769. [PMID: 36948457 DOI: 10.1016/j.repc.2022.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 09/14/2022] [Accepted: 10/11/2022] [Indexed: 03/24/2023] Open
Abstract
INTRODUCTION Current rates of permanent pacemaker implantation (PPMI) after transcatheter aortic valve implantation (TAVI) range between 3.4% and 25.9%. PPMI is associated with a worse prognosis. A lower valve implantation depth is associated with an increased risk of conduction disturbances. Theoretically, cusp-overlap projection (COP) has the potential to enable higher valve deployment. OBJECTIVE To compare the 30-day PPMI incidence post-TAVI using self-expanding valves according to the fluoroscopic guidance technique. METHODS This retrospective single-center study assessed consecutive patients undergoing TAVI with CoreValve™ valves between April 2019 and November 2021, grouped according to the fluoroscopic guidance technique (COP vs. coplanar implantation technique [CIT]). RESULTS A total of 122 patients were included, predominantly women (52.5%), with a mean age of 81.6±5.5 years. COP was used in 49.2% of the sample. The CIT group had a significantly higher prevalence of previous beta-blocker use (p<0.01), lower baseline left ventricular ejection fraction (p=0.04) and a higher EuroSCORE II (p=0.02). The 30-day PPMI rate was 27.9% (n=34), with no significant difference between the COP and CIT groups (26.7% vs. 29.0%, p=0.77). Complete atrioventricular block was the main cause (38.5%). Likewise, mean fluoroscopy time (p=0.14) and contrast volume (p=0.35) used were similar between the two groups. Radiation dose was lower in the COP group (p=0.02). There was no significant difference between post-TAVI grades III and IV aortic valve regurgitation (p=0.27) and there were no cases of periprocedural acute coronary occlusion. CONCLUSIONS This study shows that the COP technique, although safe and not associated with increased complexity, did not significantly reduce the 30-day PPMI rate compared to the traditional CIT view.
Collapse
Affiliation(s)
- Ana Rita Moura
- Cardiology Department, Hospital Distrital de Santarém, Santarém, Portugal.
| | | | - Pedro Braga
- Cardiology Department, Centro Hospitalar Vila Nova de Gaia/Espinho, Porto, Portugal
| | - Bruno Melica
- Cardiology Department, Centro Hospitalar Vila Nova de Gaia/Espinho, Porto, Portugal
| | - Lino Santos
- Cardiology Department, Centro Hospitalar Vila Nova de Gaia/Espinho, Porto, Portugal
| | - Gustavo Pires-Morais
- Cardiology Department, Centro Hospitalar Vila Nova de Gaia/Espinho, Porto, Portugal
| | - Francisco Sampaio
- Cardiology Department, Centro Hospitalar Vila Nova de Gaia/Espinho, Porto, Portugal
| | | |
Collapse
|
4
|
Sá MP, Van den Eynde J, Jacquemyn X, Erten O, Dokollari A, Sicouri S, Ramlawi B. Cusp-overlap versus coplanar view in transcatheter aortic valve implantation with self-expandable valves: A meta-analysis of comparative studies. Catheter Cardiovasc Interv 2023; 101:639-650. [PMID: 36655511 DOI: 10.1002/ccd.30562] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 12/04/2022] [Accepted: 01/08/2023] [Indexed: 01/20/2023]
Abstract
BACKGROUND Permanent pacemaker implantation (PPI) is a common complication after transcatheter aortic valve implantation (TAVI). The cusp-overlap view (COV) was adopted to reduce PPI risk after TAVI with self-expandable valves (SEVs); however, the evidence remains scarce. We performed a systematic review with meta-analysis comparing COV and the standard coplanar view (CPV) technique to evaluate their effectiveness and safety. METHODS Following the PRISMA statement, data were extracted from studies published by August 2022 and found in PubMed/MEDLINE, EMBASE, CENTRAL/CCTR, ClinicalTrials.gov, SciELO, LILACS, and Google Scholar. The primary outcome of interest was post-procedural PPI and the secondary outcomes were new left bundle branch block (LBBB), moderate/severe paravalvular leak (PVL), valve dislocation (pop-out); need of second transcatheter heart valve, 30-day mortality, stroke, conversion to surgery, coronary obstruction, implantation depth (mm), and post-TAVI mean gradients (mmHg). RESULTS Eleven studies met our eligibility criteria and included 1464 patients in the COV group and 1743 patients in the CPV group. Patients who underwent TAVI with COV had lower risk of PPI (odds ratio 0.48; 95% confidence interval [CI] 0.33-0.70; p = 0.001) and higher implantation depths with COV (mean difference -0.83; 95% CI -1.2 to -0.45; p < 0.001). We did not observe any statistically significant differences in the rates of new LBBB, moderate/severe PVL, valve dislocation, need of second transcatheter heart valve, 30-day mortality, stroke, conversion to surgery, coronary obstruction, and post-TAVI mean gradients (mmHg). CONCLUSION In TAVI with SEVs, the application of COV is associated with lower risk of PPI compared with the standard CPV without increasing risk for adverse outcomes.
Collapse
Affiliation(s)
- Michel Pompeu Sá
- Department of Cardiothoracic Surgery, Lankenau Heart Institute, Lankenau Medical Center, Main Line Health, Wynnewood, Pennsylvania, USA.,Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | | | - Xander Jacquemyn
- Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | - Ozgun Erten
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Aleksander Dokollari
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Serge Sicouri
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Basel Ramlawi
- Department of Cardiothoracic Surgery, Lankenau Heart Institute, Lankenau Medical Center, Main Line Health, Wynnewood, Pennsylvania, USA.,Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| |
Collapse
|
5
|
Chen Y, Zhu G, Liu X, Wu W, Chai H, Tao M, Kong D, Li Y, Wang L. Comparison of cusp-overlap projection and standard three-cusp coplanar view during self-expanding transcatheter aortic valve replacement: A systematic review and meta-analysis. Front Cardiovasc Med 2022; 9:927642. [PMID: 36061562 PMCID: PMC9428452 DOI: 10.3389/fcvm.2022.927642] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 07/25/2022] [Indexed: 11/23/2022] Open
Abstract
Objective Permanent pacemaker implantation (PPI) is a common complication after transcatheter aortic valve replacement (TAVR). Recently, the cusp-overlap projection (COP) technique was thought to be a feasible method to reduce PPI risk. However, the evidence is still relatively scarce. Therefore, this meta-analysis was performed to compare COP and standard three-cusp coplanar (TCC) projection technique. Methods PubMed and EMBASE databases were systematically searched for relevant literature published from the inception (EMBASE from 1974 and PubMed from 1966) to 16 April 2022, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The primary outcome of interest was post-operative (including in-hospital and 30-day) PPI. Results Total of 3,647 subjects from 11 studies were included in this meta-analysis. Of those, 1,453 underwent self-expanding TAVR using COP and 2,194 using TCC technique. In a pooled analysis, the cumulative PPI incidence was 9.3% [95% confidence interval (CI): 6.9–11.7%] and 18.9% (95% CI: 15.5–22.3%) in the COP group and TCC group, respectively. The application of the COP technique was associated with a significant PPI risk reduction (I2 = 40.3% and heterogeneity Chi-square p = 0.070, random-effects OR: 0.49, 95% CI: 0.36–0.66, p < 0.001). A higher implantation depth was achieved in the COP group compared with the TCC group [standardized mean difference (SMD) = −0.324, 95% CI: (−0.469, −0.180)]. There was no significant difference between the two groups in second valve implantation, prosthesis pop-out, fluoroscopic time, post-operative left bundle branch block, mortality, stroke, moderate/severe paravalvular leakage, mean gradient, and length of hospital stay. However, radiation doses were higher in the COP group [SMD = 0.394, 95% CI: (0.216, 0.572), p < 0.001]. Conclusion In self-expanding TAVR, the application of the cusp overlap projection technique was associated with a lower risk of PPI compared with the standard TCC technique. Systematic review registration [https://inplasy.com/inplasy-2022-4-0092/], identifier [INPLASY202240092].
Collapse
Affiliation(s)
- Yujing Chen
- Department of Hepatobiliary Surgery, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
- *Correspondence: Yujing Chen,
| | - Gangjie Zhu
- Department of Cardiology, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Xin Liu
- Department of Cardiology, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Weilin Wu
- Department of Endocrinology, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Hui Chai
- Department of Hepatobiliary Surgery, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Minjie Tao
- Department of Hepatobiliary Surgery, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Dongmei Kong
- Department of Hepatobiliary Surgery, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Yingzi Li
- Department of Hepatobiliary Surgery, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Li Wang
- Department of Hepatobiliary Surgery, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
- Li Wang,
| |
Collapse
|
6
|
Pascual I, Almendárez M, Avanzas P, Álvarez R, Arboine LA, del Valle R, Hernández-Vaquero D, Alfonso F, Morís C. La técnica de superposición de cúspides en TAVI con dispositivo autoexpandible optimiza la profundidad del implante y reduce la necesidad de marcapasos permanente. Rev Esp Cardiol 2022. [DOI: 10.1016/j.recesp.2021.05.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
7
|
Pascual I, Almendárez M, Avanzas P, Álvarez R, Arboine LA, Del Valle R, Hernández-Vaquero D, Alfonso F, Morís C. Cusp-overlapping TAVI technique with a self-expanding device optimizes implantation depth and reduces permanent pacemaker requirement. Rev Esp Cardiol (Engl Ed) 2022; 75:412-420. [PMID: 34226165 DOI: 10.1016/j.rec.2021.05.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 05/20/2021] [Indexed: 12/29/2022]
Abstract
INTRODUCTION AND OBJECTIVES This study aimed to determine the safety and efficacy of modifying the classic implantation technique for aortic transcatheter heart valve (THV) implantation to a cusp-overlap-projection (COP) technique to achieve a higher implantation depth and to reduce the burden of new permanent pacemaker implantation (PPMI) at 30 days. Aortic self-expanding THV carries an elevated risk for PPMI. A higher implantation depth minimizes the damage in the conduction system and may reduce PPMI rates. METHODS From March 2017, 226 patients were consecutively included: 113 patients were treated using the COP implantation technique compared with the previous 113 consecutive patients treated using the classic technique. In all patients, implantation depth was assessed by 3 methods (noncoronary cusp to the THV, mean of the noncoronary cusp and the left coronary cusp to the THV, and the deepest edge from the left coronary cusp and the noncoronary cusp to the THV). RESULTS The COP group had a lower implantation depth than the group treated with the classic technique (4.8 mm± 2.2 vs 5.7 mm± 3.1; P=.011; 5.8 mm± 3.1 vs 6.5 mm± 2.4; P=.095; 7.1 mm± 2.8 vs 7.4 mm±3.2; P=.392). Forty patients (17.7%) required a new PPMI after the 30-day follow-up but this requirement was significantly lower in the COP group (12.4% vs 23%, P=.036). The COP implantation technique consistently protected against the main event (OR, 0.45; 95%CI, 0.21-0.97; P=.043), with similar procedural success rates and complications. CONCLUSIONS The COP implantation technique is a simple modification of the implantation protocol and provides a higher implantation depth of self-expanding-THV with lower conduction disturbances and PPMI rates.
Collapse
Affiliation(s)
- Isaac Pascual
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain; Instituto de Investigación del Principado de Asturias, Oviedo, Spain; Departamento de Medicina, Facultad de Medicina, Universidad de Oviedo, Oviedo, Spain
| | - Marcel Almendárez
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain; Instituto de Investigación del Principado de Asturias, Oviedo, Spain
| | - Pablo Avanzas
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain; Instituto de Investigación del Principado de Asturias, Oviedo, Spain; Departamento de Medicina, Facultad de Medicina, Universidad de Oviedo, Oviedo, Spain.
| | - Rut Álvarez
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain
| | - Luis A Arboine
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain
| | - Raquel Del Valle
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain
| | - Daniel Hernández-Vaquero
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain; Instituto de Investigación del Principado de Asturias, Oviedo, Spain; Departamento de Medicina, Facultad de Medicina, Universidad de Oviedo, Oviedo, Spain
| | - Fernando Alfonso
- Departamento de Cardiología, Hospital Universitario de La Princesa, Madrid, Spain; Instituto de Investigación Sanitaria de La Princesa, Madrid, Spain
| | - César Morís
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain; Instituto de Investigación del Principado de Asturias, Oviedo, Spain; Departamento de Medicina, Facultad de Medicina, Universidad de Oviedo, Oviedo, Spain
| |
Collapse
|
8
|
Pascual I, Hernández-Vaquero D, Alperi A, Almendarez M, Avanzas P, Kalavrouziotis D, Lorca R, Mesnier J, Arboine L, Mohammadi S, Valle RD, Dumont E, Leon V, De Larochelliere R, Rodés-Cabau J, Moris C. Permanent Pacemaker Reduction Using Cusp-Overlapping Projection in TAVR: A Propensity Score Analysis. JACC Cardiovasc Interv 2022; 15:150-61. [PMID: 35057985 DOI: 10.1016/j.jcin.2021.10.002] [Citation(s) in RCA: 49] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 09/27/2021] [Accepted: 10/05/2021] [Indexed: 12/29/2022]
Abstract
OBJECTIVES The aim of this study was to determine if modifying the classical implantation technique for self-expanding (SE) transcatheter aortic valve replacement to a novel cusp-overlapping projection (COP) technique results in a higher implantation depth (ID) and subsequently reduces the rate of permanent pacemaker implantation (PPMI). BACKGROUND The COP technique presents the potential benefit of an optimized ID to reduce the rate of PPMI. However, only a few studies have compared clinical outcomes with those achieved using the standard technique. This is the first study to systematically evaluate this approach for SE transcatheter heart valves (THVs) in different populations METHODS: Beginning in February 2015, 444 patients were consecutively included. Propensity score matching was used to control baseline characteristics because of the observational nature of the study. In total, 161 pairs of patients were analyzed. Three methods were used to measure ID (noncoronary cusp [NCC] to the THV, mean of the NCC and the left coronary cusp [LCC] to the THV, and the deepest edge from the LCC and the NCC to the THV). RESULTS ID was significantly higher in COP cases when measuring from the NCC (4.2 mm vs 5.3 mm; P < 0.001) and the mean from the NCC and the LCC (5.3 mm vs 5.9 mm; P = 0.04), but not from the deepest edge. The PPMI rate was lower in the COP group: 19 (11.8%) vs 35 (21.7%) (P = 0.03; relative risk: 0.54; 95% CI: 0.32-0.91). CONCLUSIONS The present study showed that the COP technique significantly reduces PPMI in SE THV implantation compared with the classical implantation technique, with similar rates of complications.
Collapse
|
9
|
Sengupta A, Alexis SL, Lee T, Zaid S, Krishnamoorthy PM, Khera S, Lerakis S, Anastasius M, Dangas GD, Sharma SK, Kini AS, Tang GHL. Cusp Overlap Technique: Should It Become the Standard Implantation Technique for Self-expanding Valves? Curr Cardiol Rep 2021; 23:154. [PMID: 34599425 DOI: 10.1007/s11886-021-01583-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/17/2021] [Indexed: 12/19/2022]
Abstract
PURPOSE OF REVIEW Accurate imaging of the aortic root during valve implantation is crucial for proper prosthesis positioning during TAVR. The purpose of this review was to determine if routine use of the cusp-overlap view should be adopted for self-expanding valves. RECENT FINDINGS The use of the cusp-overlap view with the Evolut, Portico, ACURATE neo/neo2, and JenaValve systems is associated with lower post-procedural new permanent pacemaker implantation rates when compared with the standard 3-cusp view, presumably due to more precise valve implantation relative to the conduction system by the non-coronary cusp. By elongating the left ventricular outflow tract and accentuating the right-non commissure in the center of the fluoroscopic view, the cusp-overlap technique allows operators to more precisely control the prosthesis implant depth during self-expanding valve deployment. While the early experience with this approach in Evolut TAVR has been promising, the results of larger studies with longer follow-up across multiple self-expanding systems are warranted.
Collapse
|