Chai HH, Ye RZ, Xiong LF, Xu ZN, Chen X, Xu LJ, Hu X, Jiang LF, Peng CZ. Successful Use of a 5G-Based Robot-Assisted Remote Ultrasound System in a Care Center for Disabled Patients in Rural China.
Front Public Health 2022;
10:915071. [PMID:
35923952 PMCID:
PMC9339711 DOI:
10.3389/fpubh.2022.915071]
[Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 06/22/2022] [Indexed: 12/07/2022] Open
Abstract
Background
Disability has become a global population health challenge. Due to difficulties in self-care or independent living, patients with disability mainly live in community-based care centers or institutions for long-term care. Nonetheless, these settings often lack basic medical resources, such as ultrasonography. Thus, remote ultrasonic robot technology for clinical applications across wide regions is imperative. To date, few experiences of remote diagnostic systems in rural care centers have been reported.
Objective
To assess the feasibility of a fifth-generation cellular technology (5G)-based robot-assisted remote ultrasound system in a care center for disabled patients in rural China.
Methods
Patients underwent remote robot-assisted and bedside ultrasound examinations of the liver, gallbladder, spleen, and kidneys. We compared the diagnostic consistency and differences between the two modalities and evaluated the examination duration, image quality, and safety.
Results
Forty-nine patients were included (21 men; mean age: 61.0 ± 19.0 [range: 19–91] years). Thirty-nine and ten had positive and negative results, respectively; 67 lesions were detected. Comparing the methods, 41 and 8 patients had consistent and inconsistent diagnoses, respectively. The McNemar and kappa values were 0.727 and 0.601, respectively. The mean duration of remote and bedside examinations was 12.2 ± 4.5 (range: 5–26) min and 7.5 ± 1.8 (range: 5–13) min (p < 0.001), respectively. The median image score for original images on the patient side and transmitted images on the doctor side was 5 points (interquartile range: [IQR]: 4.7–5.0) and 4.7 points (IQR: 4.5–5.0) (p = 0.176), respectively. No obvious complications from the examination were reported.
Conclusions
A 5G-based robot-assisted remote ultrasound system is feasible and has comparable diagnostic efficiency to traditional bedside ultrasound. This system may provide a unique solution for basic ultrasound diagnostic services in primary healthcare settings.