Yan S, Song C. An in-vitro study on corn-shaped balloon-enhanced thrombolysis.
MINIM INVASIV THER 2014;
24:86-93. [PMID:
25055250 DOI:
10.3109/13645706.2014.942670]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND
Glossy balloons were used to enhance deep vein thrombolysis. However, thrombi tend to yield in the balloon dilatation due to their smooth surface. It may be preferable to enhance thrombolysis by using balloons with a rough surface, instead of balloons with a smooth surface.
MATERIAL AND METHODS
Four rabbits were used for the experiment and 60 blood clot samples were obtained, and the samples were randomly separated into one control group and four balloon-solubilised groups. Urokinase solution (5000 U/ml) was used as the thrombolytic drug. The balloon-solubilised groups were enhanced respectively by 1 atm and 2 atm pressurised glossy balloons, and 1 atm and 2 atm pressurised corn-shaped balloons. Thrombolysis rates and residual rates for different granularities of blood clots were calculated for comparasion.
RESULTS
Thrombolysis rates of the groups using corn-shaped balloons were higher than those of the groups using glossy balloons (p = 0.003 and p = 0.002). Residual rates of Φ ≥ 3.7 mm blood clots for the groups using corn-shaped balloons were lower than those for the groups using glossy balloons (p < 0.001 and p < 0.001).
CONCLUSION
Balloons could be used to enhance thrombolysis; under the same balloon dilatation pressure, thrombolysis rates when using corn-shaped balloons are better than those when using glossy balloons.
Collapse