1
|
El Ouaridi A, Ait Elcadi Z, Mkimel M, Bougteb M, El Baydaoui R. The detection instrumentation and geometric design of clinical PET scanner: towards better performance and broader clinical applications. Biomed Phys Eng Express 2024; 10:032002. [PMID: 38412520 DOI: 10.1088/2057-1976/ad2d61] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 02/27/2024] [Indexed: 02/29/2024]
Abstract
Positron emission tomography (PET) is a powerful medical imaging modality used in nuclear medicine to diagnose and monitor various clinical diseases in patients. It is more sensitive and produces a highly quantitative mapping of the three-dimensional biodistribution of positron-emitting radiotracers inside the human body. The underlying technology is constantly evolving, and recent advances in detection instrumentation and PET scanner design have significantly improved the medical diagnosis capabilities of this imaging modality, making it more efficient and opening the way to broader, innovative, and promising clinical applications. Some significant achievements related to detection instrumentation include introducing new scintillators and photodetectors as well as developing innovative detector designs and coupling configurations. Other advances in scanner design include moving towards a cylindrical geometry, 3D acquisition mode, and the trend towards a wider axial field of view and a shorter diameter. Further research on PET camera instrumentation and design will be required to advance this technology by improving its performance and extending its clinical applications while optimising radiation dose, image acquisition time, and manufacturing cost. This article comprehensively reviews the various parameters of detection instrumentation and PET system design. Firstly, an overview of the historical innovation of the PET system has been presented, focusing on instrumental technology. Secondly, we have characterised the main performance parameters of current clinical PET and detailed recent instrumental innovations and trends that affect these performances and clinical practice. Finally, prospects for this medical imaging modality are presented and discussed. This overview of the PET system's instrumental parameters enables us to draw solid conclusions on achieving the best possible performance for the different needs of different clinical applications.
Collapse
Affiliation(s)
- Abdallah El Ouaridi
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| | - Zakaria Ait Elcadi
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
- Electrical and Computer Engineering, Texas A&M University at Qatar, Doha, 23874, Qatar
| | - Mounir Mkimel
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| | - Mustapha Bougteb
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| | - Redouane El Baydaoui
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| |
Collapse
|
2
|
Kim H, Hua Y, Epel B, Sundramoorthy S, Halpern H, Chen CT, Kao CM. A Preclinical Positron Emission Tomography (PET) and Electron-Paramagnetic-Resonance-Imaging (EPRI) Hybrid System: PET Detector Module. IEEE Trans Radiat Plasma Med Sci 2023; 7:794-801. [PMID: 37981977 PMCID: PMC10655702 DOI: 10.1109/trpms.2023.3301788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2023]
Abstract
We report the design and experimental validation of a compact positron emission tomography (PET) detector module (DM) intended for building a preclinical PET and electron-paramagnetic-resonance-imaging hybrid system that supports sub-millimeter image resolution and high-sensitivity, whole-body animal imaging. The DM is eight detector units (DU) in a row. Each DU contains 12×12 lutetium-yttrium oxyorthosilicate (LYSO) crystals having a 1.05 mm pitch read by 4×4 silicon photomultipliers (SiPM) having a 3.2 mm pitch. A small-footprint, highly-multiplexing readout employing only passive electronics is devised to produce six outputs for the DM, including two outputs derived from SiPM cathodes for determining event time and active DU and four outputs derived from SiPM anodes for determining energy and active crystal. Presently, we have developed two DMs that are 1.28×10.24 cm2 in extent and approximately 1.8 cm in thickness, with their outputs sampled at 0.7 GS/s and analyzed offline. For both DMs, our results show successfully discriminated DUs and crystals. With no correction for SiPM nonlinearity, the average energy resolution for crystals in a DU ranges from 14% to 16%. While not needed for preclinical imaging, the DM may support 300-400 ps time-of-flight resolution.
Collapse
Affiliation(s)
- Heejong Kim
- Department of Radiology, University of Chicago, Chicago, Illinois, USA
| | - Yuexuan Hua
- Raycan Technology Co., Ltd., Suzhou, Jiangsu, China
| | - Boris Epel
- Department of Radiation and Cellular Oncology, University of Chicago, Chicago, Illinois, USA
| | | | - Howard Halpern
- Department of Radiation and Cellular Oncology, University of Chicago, Chicago, Illinois, USA
| | - Chin-Tu Chen
- Department of Radiology, University of Chicago, Chicago, Illinois, USA
| | - Chien-Min Kao
- Department of Radiology, University of Chicago, Chicago, Illinois, USA
| |
Collapse
|
3
|
Shida JF, Spieglan E, Adams BW, Angelico E, Domurat-Sousa K, Elagin A, Frisch HJ, La Riviere P, Squires AH. Low-Dose High-Resolution TOF-PET Using Ionization-activated Multi-State Low-Z Detector Media. Nucl Instrum Methods Phys Res A 2021; 1017:165801. [PMID: 34690392 PMCID: PMC8530277 DOI: 10.1016/j.nima.2021.165801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a 'Switchillator', that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.
Collapse
Affiliation(s)
- J F Shida
- Enrico Fermi Institute, The University of Chicago, 5640 S Ellis Ave, Chicago, IL 60637
| | - E Spieglan
- Enrico Fermi Institute, The University of Chicago, 5640 S Ellis Ave, Chicago, IL 60637
| | - B W Adams
- Quantum Optics Applied Research, Naperville, IL 60564
| | - E Angelico
- Enrico Fermi Institute, The University of Chicago, 5640 S Ellis Ave, Chicago, IL 60637
| | - K Domurat-Sousa
- Enrico Fermi Institute, The University of Chicago, 5640 S Ellis Ave, Chicago, IL 60637
| | - A Elagin
- Enrico Fermi Institute, The University of Chicago, 5640 S Ellis Ave, Chicago, IL 60637
| | - H J Frisch
- Enrico Fermi Institute, The University of Chicago, 5640 S Ellis Ave, Chicago, IL 60637
| | - P La Riviere
- Department of Radiology, The University of Chicago, Billings Hospital, P220, 5841 South Maryland Avenue, MC2026, Chicago, IL 60637
| | - A H Squires
- Pritzker School of Molecular Engineering, The University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637
| |
Collapse
|
4
|
Abstract
A recent trend in PET instrumentation is the use of silicon photomultipliers (SiPMs) for high-resolution and time-of-flight (TOF) detection. Due to its small size, a PET system can use a large number of SiPMs and hence effective and scalable multiplexing readout methods become important. Unfortunately, multiplexing readout generally degrades the fast timing properties necessary for TOF, especially at high channel reduction. Previously, we developed a stripline (SL) based readout method for PET that uses a time-based multiplexing mechanism. This method maintains fast timing by design and has been successfully used for TOF PET detectors. In this paper, we present a more systematic study in which we examine how two important design parameters of the readout - the number of inputs on an SL (n SL) and the pathlength between adjacent input positions (Δℓ) - affect its detection performance properties for PET. Our result shows that, up to n SL = 32 the readout can achieve accurate pixel discrimination and causes little degradation in the energy resolution. The TOF resolution is compromised mildly and a coincidence resolving time on the order of 300 ps FWHM can be achieved for LYSO- and SiPM-based detectors. We also discuss strategies in using the readout to further reduce the number of electronic channels that a PET system would otherwise need.
Collapse
Affiliation(s)
- Heejong Kim
- Department of Radiology, University of Chicago, Chicago, IL 60637 USA
| | - Chien-Min Kao
- Department of Radiology, University of Chicago, Chicago, IL 60637 USA
| | - Yuexuan Hua
- Raycan Technology Co., Ltd., Suzhou, Jiangsu 215163, China
| | - Qingguo Xie
- Biomedical Engineering Department, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Chin-Tu Chen
- Department of Radiology, University of Chicago, Chicago, IL 60637 USA
| |
Collapse
|
5
|
Angelico E, Elagin A, Frisch HJ, Spieglan E, Adams BW, Foley MR, Minot MJ. Air-transfer production method for large-area picosecond photodetectors. Rev Sci Instrum 2020; 91:053105. [PMID: 32486706 DOI: 10.1063/5.0008606] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 05/02/2020] [Indexed: 06/11/2023]
Abstract
We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single LAPPDTM modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside the vacuum tube and of hermetically sealing the large-perimeter window-body interface. We have also synthesized a photocathode in a large-area low-aspect-ratio volume and have shown that the micro-channel plates recover their functionality after cathode synthesis. These steps inform a design for a multi-module batch facility employing dual nested low-vacuum and ultra-high-vacuum systems in a small-footprint. The facility design provides full access to multiple MCP-PMT modules prior to hermetic pinch-off for leak-checking and real-time photocathode optimization.
Collapse
Affiliation(s)
- E Angelico
- Enrico Fermi Institute, University of Chicago, Chicago, Illinois 60637, USA
| | - A Elagin
- Enrico Fermi Institute, University of Chicago, Chicago, Illinois 60637, USA
| | - H J Frisch
- Enrico Fermi Institute, University of Chicago, Chicago, Illinois 60637, USA
| | - E Spieglan
- Enrico Fermi Institute, University of Chicago, Chicago, Illinois 60637, USA
| | - B W Adams
- Incom, Inc., Charlton, Massachusetts 01507, USA
| | - M R Foley
- Incom, Inc., Charlton, Massachusetts 01507, USA
| | - M J Minot
- Incom, Inc., Charlton, Massachusetts 01507, USA
| |
Collapse
|
6
|
Ullah MN, Pratiwi E, Cheon J, Choi H, Yeom JY. Instrumentation for Time-of-Flight Positron Emission Tomography. Nucl Med Mol Imaging 2016; 50:112-22. [PMID: 27275359 DOI: 10.1007/s13139-016-0401-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2015] [Revised: 12/08/2015] [Accepted: 01/25/2016] [Indexed: 10/22/2022] Open
Abstract
Positron emission tomography (PET) is a molecular imaging modality that provides information at the molecular level. This system is composed of radiation detectors to detect incoming coincident annihilation gamma photons emitted from the radiopharmaceutical injected into a patient's body and uses these data to reconstruct images. A major trend in PET instrumentation is the development of time-of-flight positron emission tomography (ToF-PET). In ToF-PET, the time information (the instant the radiation is detected) is incorporated for image reconstruction. Therefore, precise and accurate timing recording is crucial in ToF-PET. ToF-PET leads to better localization of the annihilation event and thus results in overall improvement in the signal-to-noise ratio (SNR) of the reconstructed image. Several factors affect the timing performance of ToF-PET. In this article, the background, early research and recent advances in ToF-PET instrumentation are presented. Emphasis is placed on the various types of scintillators, photodetectors and electronic circuitry for use in ToF-PET, and their impact on timing resolution is discussed.
Collapse
Affiliation(s)
- Muhammad Nasir Ullah
- Graduate School of Bio-Convergence Engineering, College of Health Sciences, Korea University, Seoul, South Korea
| | - Eva Pratiwi
- Graduate School of Bio-Convergence Engineering, College of Health Sciences, Korea University, Seoul, South Korea
| | - Jimin Cheon
- School of Electronic Engineering, Kumoh National Institute of Technology, Gumi, South Korea
| | - Hojong Choi
- Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi, South Korea
| | - Jung Yeol Yeom
- Graduate School of Bio-Convergence Engineering, College of Health Sciences, Korea University, Seoul, South Korea ; Department of Biomedical Engineering, Korea University, Seoul, South Korea
| |
Collapse
|
7
|
Kim H, Chen CT, Frisch H, Tang F, Kao CM. An Application of Micro-channel Plate Photomultiplier Tube to Positron Emission Tomography. Phys Procedia 2012; 37:1480-1487. [PMID: 23227135 DOI: 10.1016/j.phpro.2012.03.748] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
We are developing a Time-of-Flight Positron Emission Tomography detector using flat panel micro-channel plate photomultiplier tubes (MCP PMT). The high-speed waveform sampling data acquisition is adopted to exploit the fast time response of MCP PMT efficiently by using transmission-line readout scheme. To demonstrate the feasibility of the proposed detector, prototype detector modules were built using Photonis XP85022 MCP PMT, transmission-line board (TL), and high-speed waveform sampling electronics equipped with DRS4 chips. The MCP/TL module was coupled to single LYSO crystal, and experimental tests have been conducted in a coincidence setup to measure the responses to 511 keV annihilation photon. The details of the prototype module, experimental setup, and the preliminary results are presented and discussed.
Collapse
Affiliation(s)
- H Kim
- Department of Radiology, University of Chicago, Chicago, IL 60637
| | | | | | | | | |
Collapse
|
8
|
Kim H, Chen CT, Frisch H, Tang F, Kao CM. A Prototype TOF PET Detector Module Using a Micro-Channel Plate Photomultiplier Tube with Waveform Sampling. Nucl Instrum Methods Phys Res A 2012; 662:26-32. [PMID: 22347762 PMCID: PMC3279923 DOI: 10.1016/j.nima.2011.09.059] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We are exploring a large area flat panel micro-channel plate photomultiplier tube (MCP PMT) under development for an application to time-of-flight positron emission tomography (TOF PET). High speed waveform sampling with transmission-lines is adopted for reading out the signal with precise time and space information with a small number of low-power channels. As a demonstration of the concept, detector modules have been built using 2″×2″ Photonis Planacon MCP PMTs (XP85022) and prototype transmission-line (TL) boards. The signals from the MCP PMT through the transmission-lines are sampled by DRS4 evaluation boards running at 5 giga-samples per second (GS/s). The event information is extracted by processing the digitized waveforms. For experimental tests, a single 3×3×10 mm(3) LYSO crystal is optically coupled to each MCP PMT; the detector responses to 511 keV annihilation photon from a (22)Na source are measured using the data taken in coincidence mode. As a preliminary result, we obtain a position resolution of ∼2.8 mm (0.3 mm) (FWHM) along (perpendicular to) the transmission-line, ∼309 ps (FWHM) for coincidence time resolution, and ∼14% (FWHM) of energy resolution at 511 keV. This initial result gives a promise that the large area MCP PMT is applicable to TOF PET.
Collapse
Affiliation(s)
- H. Kim
- Department of Radiology, University of Chicago, Chicago, IL 60637
| | - C.-T. Chen
- Department of Radiology, University of Chicago, Chicago, IL 60637
| | - H. Frisch
- Enrico Fermi Institute, University of Chicago, Chicago, IL 60637
| | - F. Tang
- Enrico Fermi Institute, University of Chicago, Chicago, IL 60637
| | - C.-M. Kao
- Department of Radiology, University of Chicago, Chicago, IL 60637
| |
Collapse
|
9
|
Spanoudaki VC, Levin CS. Investigating the temporal resolution limits of scintillation detection from pixellated elements: comparison between experiment and simulation. Phys Med Biol 2011; 56:735-56. [PMID: 21239845 DOI: 10.1088/0031-9155/56/3/013] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This study investigates the physical limitations involved in the extraction of accurate timing information from pixellated scintillation detectors for positron emission tomography (PET). Accurate physical modeling of the scintillation detection process, from scintillation light generation through detection, is devised and performed for varying detector attributes, such as the crystal element length, light yield, decay time and surface treatment. The dependence of light output and time resolution on these attributes, as well as on the photon interaction depth (DoI) of the annihilation quanta within the crystal volume, is studied and compared with experimental results. A theoretical background which highlights the importance of different time blurring factors for instantaneous ('ideal') and exponential ('realistic') scintillation decay is developed and compared with simulated data. For the case of a realistic scintillator, our experimental and simulation findings suggest that dependence of detector performance on DoI is more evident for crystal elements with rough ('as cut') compared to polished surfaces (maximum observed difference of 64% (25%) and 22% (19%) in simulation (measurement) for light output and time resolution, respectively). Furthermore we observe distinct trends of the detector performance dependence on detector element length and surface treatment. For short crystals (3 × 3 × 5 mm(3)) an improvement in light output and time resolution for 'as cut' compared to polished crystals is observed (3% (7%) and 9% (9%) for simulation (measurement), respectively). The trend is reversed for longer crystals (3 × 3 × 20 mm(3)) and an improvement in light output and time uncertainty for polished compared to 'as cut' crystals is observed (36% (6%) and 40% (20%) for simulation (measurement), respectively). The results of this study are used to guide the design of PET detectors with combined time of flight (ToF) and DoI features.
Collapse
Affiliation(s)
- V Ch Spanoudaki
- Molecular Imaging Program at Stanford (MIPS), Stanford University, Stanford, USA
| | | |
Collapse
|