Luan S, Ji Y, Liu Y, Zhu L, Zhou H, Ouyang J, Yang X, Zhao H, Zhu B. Real-Time Reconstruction of HIFU Focal Temperature Field Based on Deep Learning. BME Front 2024; 5:0037. [PMID: 38515637 PMCID: PMC10956737 DOI: 10.34133/bmef.0037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 02/07/2024] [Indexed: 03/23/2024] Open
Abstract
Objective and Impact Statement: High-intensity focused ultrasound (HIFU) therapy is a promising noninvasive method that induces coagulative necrosis in diseased tissues through thermal and cavitation effects, while avoiding surrounding damage to surrounding normal tissues. Introduction: Accurate and real-time acquisition of the focal region temperature field during HIFU treatment marked enhances therapeutic efficacy, holding paramount scientific and practical value in clinical cancer therapy. Methods: In this paper, we initially designed and assembled an integrated HIFU system incorporating diagnostic, therapeutic, and temperature measurement functionalities to collect ultrasound echo signals and temperature variations during HIFU therapy. Furthermore, we introduced a novel multimodal teacher-student model approach, which utilizes the shared self-expressive coefficients and the deep canonical correlation analysis layer to aggregate each modality data, then through knowledge distillation strategies, transfers the knowledge from the teacher model to the student model. Results: By investigating the relationship between the phantoms, in vitro, and in vivo ultrasound echo signals and temperatures, we successfully achieved real-time reconstruction of the HIFU focal 2D temperature field region with a maximum temperature error of less than 2.5 °C. Conclusion: Our method effectively monitored the distribution of the HIFU temperature field in real time, providing scientifically precise predictive schemes for HIFU therapy, laying a theoretical foundation for subsequent personalized treatment dose planning, and providing efficient guidance for noninvasive, nonionizing cancer treatment.
Collapse
Affiliation(s)
- Shunyao Luan
- School of Integrated Circuits, Laboratory for Optoelectronics,
Huazhong University of Science and Technology, Wuhan, China
| | - Yongshuo Ji
- HIFU Center of Oncology Department,
Huadong Hospital Affiliated to Fudan University, Shanghai, China
| | - Yumei Liu
- HIFU Center of Oncology Department,
Huadong Hospital Affiliated to Fudan University, Shanghai, China
| | - Linling Zhu
- HIFU Center of Oncology Department,
Huadong Hospital Affiliated to Fudan University, Shanghai, China
| | - Haoyu Zhou
- School of Integrated Circuits, Laboratory for Optoelectronics,
Huazhong University of Science and Technology, Wuhan, China
| | - Jun Ouyang
- School of Integrated Circuits, Laboratory for Optoelectronics,
Huazhong University of Science and Technology, Wuhan, China
| | - Xiaofei Yang
- School of Integrated Circuits, Laboratory for Optoelectronics,
Huazhong University of Science and Technology, Wuhan, China
| | - Hong Zhao
- HIFU Center of Oncology Department,
Huadong Hospital Affiliated to Fudan University, Shanghai, China
| | - Benpeng Zhu
- School of Integrated Circuits, Laboratory for Optoelectronics,
Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
2
|
Huang W, Ning C, Zhang R, Xu J, Chen B, Li Z, Cui Y, Shao W. Evaluation of the dual-frequency transducer for controlling thermal ablation morphology using frequency shift keying signal. Int J Hyperthermia 2022; 39:1344-1357. [PMID: 36223887 DOI: 10.1080/02656736.2022.2130999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
PURPOSE The catheter-based ultrasound (CBUS) can reach the target tissue directly and achieve rapid treatment. The frequency shift keying (FSK) signal is proposed to regulate and evaluate tumor ablation by a miniaturized dual-frequency transducer. METHODS A dual-frequency transducer prototype (3 × 7 × 0.4 mm) was designed and fabricated for the CBUS applicator (OD: 3.8 mm) based on the fundamental frequency of 5.21 MHz and the third harmonic frequency of 16.88 MHz. Then, the acoustic fields and temperature field distributions using the FSK signals (with 0, 25, 50, 75, and 100% third harmonic frequency duty ratios) were simulated by finite element analysis. Finally, tissue ablation and temperature monitoring were performed in phantom and ex vivo tissue, respectively. RESULTS At the same input electrical power (20 W), the output acoustic power of the fundamental frequency of the transducer was 10.03 W (electroacoustic efficiencies: 50.1%), and that of the third harmonic frequency was 6.19 W (30.6%). As the third harmonic frequency duty ratios increased, the shape of thermal lesions varied from strip to droplet in simulated and phantom experimental results. The same trend was observed in ex vivo tests. CONCLUSION Dual-frequency transducers excited by the FSK signal can control the morphology of lesions. SIGNIFICANCE The acoustic power deposition of CBUS was optimized to achieve precise ablation.
Collapse
Affiliation(s)
- Wenchang Huang
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Suzhou, Jiangsu, China.,Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| | - Chuanlong Ning
- College of Mechanical and Electrical Engineering, Hohai University, Changzhou, Jiangsu, China
| | - Rui Zhang
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Suzhou, Jiangsu, China.,Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| | - Jie Xu
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| | - Beiyi Chen
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Suzhou, Jiangsu, China.,Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| | - Zhangjian Li
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| | - Yaoyao Cui
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| | - Weiwei Shao
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| |
Collapse
|
3
|
Behnia A, Behnam H, Shaswary E, Tavakkoli J. Thermometry using entropy imaging of ultrasound radio frequency signal time series. Proc Inst Mech Eng H 2022; 236:1502-1512. [DOI: 10.1177/09544119221122645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Low intensity focused ultrasound (LIFU) is a novel approach that could activate drug release and considerably improve the delivery of anticancer drug. LIFU treatment has some features like is able to penetrate deep into the tissue and being non-invasive, as a consequence LIFU displays great capability for controlling the drug release and improving the chemotherapy treatment efficiency. The goal of this study is to research the feasibility of the entropy parameter of RF time series of ultrasound backscattered signals for measuring the changes in temperature induced by a LIFU device. Entropy Imaging is a technique for reconstructing ultrasound images based on the average uncertainty of time-series in a signal. Furthermore, the Shannon Entropy can quantify the uncertainty of a random process and is usually used as a measure for the information content of probability distributions. In this study, we use the Entropy Imaging method for measuring the LIFU-induced temperature changes in the deep region of ex vivo porcine tissue samples. The results obtained show that the changes of entropy parameter of RF time series signal are proportional to temperature changes recorded by a calibrated thermocouple in the temperature range of 37–47°C. In conclusion, in this study we show that Shannon entropy of RF time series signal possesses promising features like succinctly capturing the available information in a system by considering the uncertainty in a given data that can be used, as a new method, to measure temperature changes non-invasively and quantitatively in the deep region of tissue.
Collapse
Affiliation(s)
- Ashkan Behnia
- School of Electrical Engineering, Department of Biomedical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Hamid Behnam
- School of Electrical Engineering, Department of Biomedical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Elyas Shaswary
- Department of Physics, Ryerson University, Toronto, ON, Canada
| | - Jahan Tavakkoli
- Department of Physics, Ryerson University, Toronto, ON, Canada
- Keenan Research Centre for Biomedical Science, Institute for Biomedical Engineering, Science and Technology (iBEST), St. Michael’s Hospital, Toronto, ON, Canada
| |
Collapse
|
4
|
Xin Y, Zhang A, Xu LX, Fowlkes JB. Numerical Study of Bubble Cloud and Thermal Lesion Evolution During Acoustic Droplet Vaporization Enhanced HIFU Treatment. J Biomech Eng 2022; 144:1119457. [PMID: 34505142 DOI: 10.1115/1.4052374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Indexed: 11/08/2022]
Abstract
Acoustic droplet vaporization (ADV) has been proven to enhance high intensity focused ultrasound (HIFU) thermal ablation of tumor. It has also been demonstrated that triggering droplets before HIFU exposure could be a potential way to control both the size and the shape of the thermal lesion. In this paper, a numerical model is proposed to predict the thermal lesion created in ADV enhanced HIFU treatment. Bubble oscillation was coupled into a viscoelastic medium in the model to more closely represent real applications in tissues. Several physical processes caused by continuous wave ultrasound and elevated temperature during the HIFU exposure were considered, including rectified diffusion, gas solubility variation with temperature in the medium, and boiling. Four droplet concentrations spanning two orders of magnitude were calculated. The bubble cloud formed from triggering of the droplets by the pulse wave ultrasound, along with the evolution of the shape and location of the bubble cloud and thermal lesion during the following continuous wave exposure was obtained. The increase of bubble void fraction caused by continuous wave exposure was found to be consistent with the experimental observation. With the increase of droplet concentration, the predicted bubble cloud shapes vary from tadpole to triangular and double triangular, while the thermal lesions move toward the transducer. The results show that the assumptions used in this model increased the accuracy of the results. This model may be used for parametrical study of ADV enhanced HIFU treatment and be further used for treatment planning and optimization in the future.
Collapse
Affiliation(s)
- Ying Xin
- School of Biomedical Engineering, Shanghai Jiao Tong University, 400 Med-X Research Institute, 1954 Huashan Road, Shanghai 200030, China
| | - Aili Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, 400 Med-X Research Institute, 1954 Huashan Road, Shanghai 200030, China
| | - Lisa X Xu
- School of Biomedical Engineering, Shanghai Jiao Tong University, 400 Med-X Research Institute, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030, China
| | - J Brian Fowlkes
- Department of Radiology, University of Michigan Health System, 3226C, Medical Sciences Building I, 1301 Catherine Street, Ann Arbor, MI 48109
| |
Collapse
|
5
|
Dong H, Liu G, Tong X. Influence of temperature-dependent acoustic and thermal parameters and nonlinear harmonics on the prediction of thermal lesion under HIFU ablation. Math Biosci Eng 2021; 18:1340-1351. [PMID: 33757188 DOI: 10.3934/mbe.2021070] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
According to the traditional method of high intensity focused ultrasound (HIFU) treatment, the acoustic and thermal characteristic parameters of constant temperature (room temperature or body temperature) are used to predict thermal lesion. Based on the nonlinear spherical beam equation (SBE) and Pennes bio-heat transfer equation, and a new acoustic-thermal coupled model is proposed. The constant and temperature-dependent acoustic and thermal characteristic parameters are used to predict thermal lesion, and the predicted lesion area are compared with each other. Moreover, the relationship between harmonic amplitude ratio (P2/P1) and thermal lesion is studied. Combined with the known experimental data of acoustic and thermal characteristic parameters of biological tissue and data fitting method, the relationship between acoustic and thermal characteristic parameters and temperature is obtained; and the thermal lesion simulation calculation is carried out by using the acoustic and thermal characteristic parameters under constant temperature and temperature- dependent acoustic and thermal characteristic parameters, respectively. The simulation results show that under the same irradiation condition, the thermal lesion predicted by temperature-dependent acoustic and thermal characteristic parameters is larger than that predicted by traditional method, and the thermal lesion increases with the decrease of harmonic amplitude ratio.
Collapse
Affiliation(s)
- Hu Dong
- School of Information Science and Engineering, Changsha Normal University, Changsha 410100, China
| | - Gang Liu
- School of Physics and Electronics, Central South University, Changsha 410083, China
| | - Xin Tong
- School of Information Science and Engineering, Changsha Normal University, Changsha 410100, China
| |
Collapse
|
6
|
Tang Y, Chen LY, Zhang A, Liao CP, Gross ME, Kim ES. In Vivo Non-Thermal, Selective Cancer Treatment With High-Frequency Medium-Intensity Focused Ultrasound. IEEE Access 2021; 9:122051-122066. [PMID: 35321234 PMCID: PMC8939762 DOI: 10.1109/access.2021.3108548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Focused ultrasound (FUS) has proven its efficacy in non-invasive, radiation-free cancer treatment. However, the commonly used low-frequency high-intensity focused ultrasound (HIFU) destroys both cancerous and healthy tissues non-specifically through extreme heat and inertial cavitation with low spatial resolution. To address this issue, we evaluate the therapeutic effects of pulsed (60 Hz pulse repetition frequency, 1.45 ms pulse width) high-frequency (20.7 MHz) medium-intensity (spatial-peak pulse-average intensity ISPPA < 279.1 W/cm2, spatial-peak temporal-average intensity ISPTA < 24.3 W/cm2) focused ultrasound (pHFMIFU) for selective cancer treatment without thermal damage and with low risk of inertial cavitation (mechanical index < 0.66), in an in vivo subcutaneous B16F10 melanoma tumor growth model in mice. The pHFMIFU with 104 μm focal diameter is generated by a microfabricated self-focusing acoustic transducer (SFAT) with a Fresnel acoustic lens. A three-axis positioning system has been developed for automatic scanning of the transducer to cover a larger treatment volume, while a water-cooling system is custom-built for dissipating non-acoustic heat from the transducer surface. Initial testing revealed that pHFMIFU treatment can be applied to a living animal while maintaining skin temperature under 35.6 °C without damaging normal skin and tissue. After eleven days of treatment with pHFMIFU, the treated tumors were significantly smaller with large areas of necrosis and apoptosis in the treatment field compared to untreated controls. Potential mechanisms of this selective, non-thermal killing effect, as well as possible causes of and solutions to the variation in treatment results, have been analyzed and proposed. The pHFMIFU could potentially be used as a new therapeutic modality for safer cancer treatment especially in critical body regions, due to its cancer-specific effects and high spatial resolution.
Collapse
Affiliation(s)
- Yongkui Tang
- Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA 90089, USA
| | - Leng-Ying Chen
- Lawrence J. Ellison Institute for Transformative Medicine, University of Southern California, Los Angeles, CA 90064, USA
| | - Ailin Zhang
- Lawrence J. Ellison Institute for Transformative Medicine, University of Southern California, Los Angeles, CA 90064, USA
| | - Chun-Peng Liao
- Lawrence J. Ellison Institute for Transformative Medicine, University of Southern California, Los Angeles, CA 90064, USA
| | - Mitchell Eric Gross
- Lawrence J. Ellison Institute for Transformative Medicine, University of Southern California, Los Angeles, CA 90064, USA
| | - Eun Sok Kim
- Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA 90089, USA
| |
Collapse
|
7
|
Zhang J, Chauhan S. Fast computation of soft tissue thermal response under deformation based on fast explicit dynamics finite element algorithm for surgical simulation. Comput Methods Programs Biomed 2020; 187:105244. [PMID: 31805458 DOI: 10.1016/j.cmpb.2019.105244] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 11/03/2019] [Accepted: 11/26/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND AND OBJECTIVES During thermal heating surgical procedures such as electrosurgery, thermal ablative treatment and hyperthermia, soft tissue deformation due to surgical tool-tissue interaction and patient movement can affect the distribution of thermal energy induced. Soft tissue temperature must be obtained from the deformed tissue for precise delivery of thermal energy. However, the classical Pennes bio-heat transfer model can handle only the static non-moving state of tissue. In addition, in order to enable a surgeon to visualise the simulated results immediately, the solution procedure must be suitable for real-time thermal applications. METHODS This paper presents a formulation of bio-heat transfer under the effect of soft tissue deformation for fast or near real-time tissue temperature prediction, based on fast explicit dynamics finite element algorithm (FED-FEM) for transient heat transfer. The proposed thermal analysis under deformation is achieved by transformation of the unknown deformed tissue state to the known initial static state via a mapping function. The appropriateness and effectiveness of the proposed formulation are evaluated on a realistic virtual human liver model with blood vessels to demonstrate a clinically relevant scenario of thermal ablation of hepatic cancer. RESULTS For numerical accuracy, the proposed formulation can achieve a typical 10-3 level of normalised relative error at nodes and between 10-4 and 10-5 level of total errors for the simulation, by comparing solutions against the commercial finite element analysis package. For computation time, the proposed formulation under tissue deformation with anisotropic temperature-dependent properties consumes 2.518 × 10-4 ms for one element thermal loads computation, compared to 2.237 × 10-4 ms for the formulation without deformation which is 0.89 times of the former. Comparisons with three other formulations for isotropic and temperature-independent properties are also presented. CONCLUSIONS Compared to conventional methods focusing on numerical accuracy, convergence and stability, the proposed formulation focuses on computational performance for fast tissue thermal analysis. Compared to the classical Pennes model that handles only the static state of tissue, the proposed formulation can achieve fast thermal analysis on deformed states of tissue and can be applied in addition to tissue deformable models for non-linear heating analysis at even large deformation of soft tissue, leading to great translational potential in dynamic tissue temperature analysis and thermal dosimetry computation for computer-integrated medical education and personalised treatment.
Collapse
Affiliation(s)
- Jinao Zhang
- Department of Mechanical and Aerospace Engineering, Monash University, Wellington Road, Clayton, VIC 3800, Australia.
| | - Sunita Chauhan
- Department of Mechanical and Aerospace Engineering, Monash University, Wellington Road, Clayton, VIC 3800, Australia
| |
Collapse
|
8
|
Mohammadpour M, Firoozabadi B. Numerical study of the effect of vascular bed on heat transfer during high intensity focused ultrasound (HIFU) ablation of the liver tumor. J Therm Biol 2019; 86:102431. [DOI: 10.1016/j.jtherbio.2019.102431] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 08/30/2019] [Accepted: 10/04/2019] [Indexed: 01/20/2023]
|
9
|
Zhang J, Chauhan S. Neural network methodology for real-time modelling of bio-heat transfer during thermo-therapeutic applications. Artif Intell Med 2019; 101:101728. [DOI: 10.1016/j.artmed.2019.101728] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Revised: 07/30/2019] [Accepted: 09/26/2019] [Indexed: 12/26/2022]
|
10
|
Abdolhosseinzadeh A, Mojra A, Ashrafizadeh A. A numerical study on thermal ablation of brain tumor with intraoperative focused ultrasound. J Therm Biol 2019; 83:119-133. [DOI: 10.1016/j.jtherbio.2019.05.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 05/13/2019] [Accepted: 05/19/2019] [Indexed: 02/07/2023]
|
11
|
Tan Q, Zou X, Ding Y, Zhao X, Qian S. The Influence of Dynamic Tissue Properties on HIFU Hyperthermia: A Numerical Simulation Study. Applied Sciences 2018; 8:1933. [DOI: 10.3390/app8101933] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Accurate temperature and thermal dose prediction are crucial to high-intensity focused ultrasound (HIFU) hyperthermia, which has been used successfully for the non-invasive treatment of solid tumors. For the conventional method of prediction, the tissue properties are usually set as constants. However, the temperature rise induced by HIFU irradiation in tissues will cause changes in the tissue properties that in turn affect the acoustic and temperature field. Herein, an acoustic–thermal coupling model is presented to predict the temperature and thermal damage zone in tissue in terms of the Westervelt equation and Pennes bioheat transfer equation, and the individual influence of each dynamic tissue property and the joint effect of all of the dynamic tissue properties are studied. The simulation results show that the dynamic acoustic absorption coefficient has the greatest influence on the temperature and thermal damage zone among all of the individual dynamic tissue properties. In addition, compared with the conventional method, the dynamic acoustic absorption coefficient leads to a higher focal temperature and a larger thermal damage zone; on the contrary, the dynamic blood perfusion leads to a lower focal temperature and a smaller thermal damage zone. Moreover, the conventional method underestimates the focal temperature and the thermal damage zone, compared with the simulation that was performed using all of the dynamic tissue properties. The results of this study will be helpful to guide the doctors to develop more accurate clinical protocols for HIFU treatment planning.
Collapse
|
12
|
Dillon CR, Rieke V, Ghanouni P, Payne A. Thermal diffusivity and perfusion constants from in vivo MR-guided focussed ultrasound treatments: a feasibility study. Int J Hyperthermia 2017; 34:352-362. [DOI: 10.1080/02656736.2017.1340677] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Affiliation(s)
- Christopher R. Dillon
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Viola Rieke
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA
| | - Pejman Ghanouni
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Allison Payne
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
13
|
Sun MK, Shieh J, Chen CS, Chiang H, Huang CW, Chen WS. Effects of an implant on temperature distribution in tissue during ultrasound diathermy. Ultrason Sonochem 2016; 32:44-53. [PMID: 27150744 DOI: 10.1016/j.ultsonch.2016.02.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Revised: 02/02/2016] [Accepted: 02/02/2016] [Indexed: 06/05/2023]
Abstract
The effects of an implant on temperature distribution in a tissue-mimicking hydrogel phantom during the application of therapeutic ultrasound were investigated. In vitro experiments were conducted to compare the influences of plastic and metal implants on ultrasound diathermy and to calibrate parameters in finite element simulation models. The temperature histories and characteristics of the opaque (denatured) areas in the hydrogel phantoms predicted by the numerical simulations show good correlation with those observed in the in vitro experiments. This study provides an insight into the temperature profile in the vicinity of an implant by therapeutic ultrasound heating typically used for physiotherapy. A parametric study was conducted through numerical simulations to investigate the effects of several factors, such as implant material type, ultrasound operation frequency, implant thickness and tissue thickness on the temperature distribution in the hydrogel phantom. The results indicate that the implant material type and implant thickness are the main parameters influencing the temperature distribution. In addition, once the implant material and ultrasound operation frequency are chosen, an optimal implant thickness can be obtained so as to avoid overheating injuries in tissue.
Collapse
Affiliation(s)
- Ming-Kuan Sun
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan
| | - Jay Shieh
- Department of Materials Science and Engineering, National Taiwan University, Taipei, Taiwan
| | - Chuin-Shan Chen
- Department of Civil Engineering, National Taiwan University, Taipei, Taiwan
| | - Hongsen Chiang
- Department of Orthopedic Surgery, National Taiwan University Hospital, Taipei, Taiwan
| | - Chang-Wei Huang
- Department of Civil Engineering, Chung Yuan Christian University, Taoyuan, Taiwan.
| | - Wen-Shiang Chen
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan; Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan.
| |
Collapse
|
14
|
Johnson SL, Dillon C, Odéen H, Parker D, Christensen D, Payne A. Development and validation of a MRgHIFU non-invasive tissue acoustic property estimation technique. Int J Hyperthermia 2016; 32:723-34. [PMID: 27441427 DOI: 10.1080/02656736.2016.1216184] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
MR-guided high-intensity focussed ultrasound (MRgHIFU) non-invasive ablative surgeries have advanced into clinical trials for treating many pathologies and cancers. A remaining challenge of these surgeries is accurately planning and monitoring tissue heating in the face of patient-specific and dynamic acoustic properties of tissues. Currently, non-invasive measurements of acoustic properties have not been implemented in MRgHIFU treatment planning and monitoring procedures. This methods-driven study presents a technique using MR temperature imaging (MRTI) during low-temperature HIFU sonications to non-invasively estimate sample-specific acoustic absorption and speed of sound values in tissue-mimicking phantoms. Using measured thermal properties, specific absorption rate (SAR) patterns are calculated from the MRTI data and compared to simulated SAR patterns iteratively generated via the Hybrid Angular Spectrum (HAS) method. Once the error between the simulated and measured patterns is minimised, the estimated acoustic property values are compared to the true phantom values obtained via an independent technique. The estimated values are then used to simulate temperature profiles in the phantoms, and compared to experimental temperature profiles. This study demonstrates that trends in acoustic absorption and speed of sound can be non-invasively estimated with average errors of 21% and 1%, respectively. Additionally, temperature predictions using the estimated properties on average match within 1.2 °C of the experimental peak temperature rises in the phantoms. The positive results achieved in tissue-mimicking phantoms presented in this study indicate that this technique may be extended to in vivo applications, improving HIFU sonication temperature rise predictions and treatment assessment.
Collapse
Affiliation(s)
- Sara L Johnson
- a Department of Bioengineering , University of Utah , Salt Lake City , UT , USA
| | - Christopher Dillon
- b Department of Radiology and Imaging Sciences , University of Utah , Salt Lake City , UT , USA
| | - Henrik Odéen
- b Department of Radiology and Imaging Sciences , University of Utah , Salt Lake City , UT , USA
| | - Dennis Parker
- b Department of Radiology and Imaging Sciences , University of Utah , Salt Lake City , UT , USA
| | - Douglas Christensen
- a Department of Bioengineering , University of Utah , Salt Lake City , UT , USA ;,c Department of Electrical and Computer Engineering , University of Utah , Salt Lake City , UT , USA
| | - Allison Payne
- b Department of Radiology and Imaging Sciences , University of Utah , Salt Lake City , UT , USA
| |
Collapse
|
15
|
Chartier T, Carpentier O, Genestie B, Hornez JC, Monchau F. Numerical and ex vivo studies of a bioprobe developed for laser-induced thermotherapy (LITT) in contact with liver tissue. Med Eng Phys 2016; 38:733-40. [PMID: 27212211 DOI: 10.1016/j.medengphy.2016.04.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2015] [Revised: 03/24/2016] [Accepted: 04/24/2016] [Indexed: 11/20/2022]
Abstract
This work is based on the production of a bioprobe that is compatible with magnetic resonance imaging (MRI) for laser-induced thermotherapy (LITT) in liver cancer laser therapy. This probe is made of an alumina tube (3-mm diameter) in which an optical fibre is centred and fixed. A shooting window (20mm) is created using a mechanical rectifier. The device is then consolidated by the injection of a transparent and heat-resistant resin. Through numerical modelling, the thermal power damping of the laser source is evaluated as well as the propagation of the heat in the ex vivo liver tissue according to different heating scenarios. These analyses allow for an estimation of the irradiated volume. Ex vivo tests were performed on bovine liver to confirm the adequacy of the bioprobe for LITT and of the irradiated volumes predicted by the numerical model. There was a difference of 8% between the simulations and ex vivo experiments. The pulsed mode heating scenario was the most effective under the experimental conditions.
Collapse
|