1
|
Pyrene Derivative Incorporated Ni MOF as an Enzyme Mimic for Noninvasive Salivary Glucose Detection Toward Diagnosis of Diabetes Mellitus. ACS APPLIED MATERIALS & INTERFACES 2024; 16:17219-17231. [PMID: 38561895 DOI: 10.1021/acsami.3c19431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Herein, we demonstrate the detection of glucose in a noninvasive and nonenzymatic manner by utilizing an extended gate field-effect transistor (EGFET) based on the organic molecule pyrene phosphonic acid (PyP4OH8) incorporated nickel metal-organic framework (NiOM-MOF). The prepared electrode responds selectively to glucose instead of sucrose, fructose, maltose, ascorbic acid, and uric acid in a 1× phosphate buffer saline solution. Also, utilizing the scanning Kelvin probe system, the sensing electrode's work function (Φ) is measured to validate the glucose-sensing mechanism. The sensitivity, detection range, response time, limit of detection, and limit of quantification of the electrode are determined to be 24.5 μA mM-1 cm-2, 20 μM to 10 mM, less than 5 s, 2.73 μM, and 8.27 μM, respectively. Most interestingly, the developed electrode follows the Michaelis-Menten kinetics, and the calculated rate constant (km) 0.07 mM indicates a higher affinity of NiOM-MOF toward glucose. The real-time analysis has revealed that the prepared electrode is sensitive to detect glucose in real human saliva, and it can be an alternative device for the noninvasive detection of glucose. Overall, the outcomes of the EGFET studies demonstrate that the prepared electrodes are well-suited for expeditious detection of glucose levels in saliva.
Collapse
|
2
|
Electrodeposition of CoFeS nanoflakes on Cu 2O nanospheres as an ultrasensitive sensing platform for measurement of the hydrazine and hydrogen peroxide in seawater sample. CHEMOSPHERE 2024; 352:141340. [PMID: 38301836 DOI: 10.1016/j.chemosphere.2024.141340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 01/16/2024] [Accepted: 01/29/2024] [Indexed: 02/03/2024]
Abstract
Nanoarchitectured design of the metal sulfides with highly available surface and abundant electroactive centers and using them as electrocatalyst for fabricate the electrochemical sensors for the detection of hydrazine (N2H4) and hydrogen peroxide (H2O2) is challenging and desirable. Herein, Cu2O nanospheres powder is firstly prepared using chemical reduction of copper chloride and then drop-casted on the glassy carbon electrode (GCE) surface. In the next step, CoFeS nanoflakes are electrodeposited on Cu2O nanospheres by cyclic voltammetry method to form CoFeS/Cu2O nanocomposite as a detection platform for measuring N2H4 and H2O2. Accordingly, Cu2O nanospheres are not only used as substrate, but also guided the CoFeS nanoflakes to adhere to the electrode surface without need to any binder or conductive additive, which enhances the electrical conductivity of the sensing active materials. As the hydrazine sensor, the CoFeS/Cu2O/GCE displayed wide linear ranges (0.0001-0.021 mM and 0.021-1.771 mM), low detection limit (0.12 μM), very high sensitivities (103.33 and 21.23 mA mM-1 cm-2), and excellent selectivity. The as-made nanocomposite also exhibited low detection limit of 1.26 μM for H2O2 sensing with very high sensitivities (12.31 and 3.96 mA mM-1 cm-2) for linear ranges of 0.001-0.03 mM and 0.03-2.03 mM, respectively, and negligible response against interfering substances. The superior analytical performance of the CoFeS/Cu2O for N2H4 electro-oxidation and H2O2 electro-reduction can be attributed to structure stability, high electroactive surface area, and good availability to analyte species and electrolyte diffusion. Moreover, to examine the potency of the prepared nanocomposite in real applications, the seawater sample was analyzed and results display that the CoFeS/Cu2O/GCE can be utilized as a reliable and applicable platform for measuring N2H4 and H2O2.
Collapse
|
3
|
Current advancements and prospects of enzymatic and non-enzymatic electrochemical glucose sensors. Int J Biol Macromol 2023; 253:126680. [PMID: 37673151 DOI: 10.1016/j.ijbiomac.2023.126680] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/19/2023] [Accepted: 09/01/2023] [Indexed: 09/08/2023]
Abstract
This review discusses the most current developments and future perspectives in enzymatic and non-enzymatic glucose sensors, which have notably evolved over the preceding quadrennial period. Furthermore, a thorough exploration encompassed the sensor's intricate fabrication processes, the diverse range of materials employed, the underlying principles of detection, and an in-depth assessment of the sensors' efficacy in detecting glucose levels within essential bodily fluids such as human blood serums, urine, saliva, and interstitial fluids. It is worth noting that the accurate quantification of glucose concentrations within human blood has been effectively achieved by utilizing classical enzymatic sensors harmoniously integrated with optical and electrochemical transduction mechanisms. Monitoring glucose levels in various mediums has attracted exceptional attention from industrial to academic researchers for diabetes management, food quality control, clinical medicine, and bioprocess inspection. There has been an enormous demand for the creation of novel glucose sensors over the past ten years. Research has primarily concentrated on succeeding biocompatible and enhanced sensing abilities related to the present technologies, offering innovative avenues for more effective glucose sensors. Recent developments in wearable optical and electrochemical sensors with low cost, high stability, point-of-care testing, and online tracking of glucose concentration levels in biological fluids can aid in managing and controlling diabetes globally. New nanomaterials and biomolecules that can be used in electrochemical sensor systems to identify glucose concentration levels are developed thanks to advances in nanoscience and nanotechnology. Both enzymatic and non-enzymatic glucose electrochemical sensors have garnered much interest recently and have made significant strides in detecting glucose levels. In this review, we summarise several categories of non-enzymatic glucose sensor materials, including composites, non-precious transition metals and their metal oxides, hydroxides, precious metals and their alloys, carbon-based materials, conducting polymers, metal-organic framework (MOF)-based electrocatalysts, and wearable device-based glucose sensors deeply.
Collapse
|
4
|
Cu Aerogels with Sustainable Cu(I)/Cu(II) Redox Cycles for Sensitive Nonenzymatic Glucose Sensing. Adv Healthc Mater 2023; 12:e2301073. [PMID: 37285868 DOI: 10.1002/adhm.202301073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 06/05/2023] [Indexed: 06/09/2023]
Abstract
Developing functional nanomaterials for nonenzymatic glucose electrochemical sensing platforms is vital and challenging from the perspective of pathology and physiology. Accurate identification of active sites and thorough investigation of catalytic mechanisms are critical prerequisites for the design of advanced catalysts for electrochemical sensing. Herein, Cu aerogels are synthesized as a model system for sensitive nonenzymatic glucose sensing. The resultant Cu aerogels exhibit good catalytic activity for glucose electrooxidation with high sensitivity and a low detection limit. Significantly, in situ electrochemical investigations and Raman characterizations reveal the catalytic mechanism of Cu-based nonenzymatic glucose sensing. During the electrocatalytic oxidation of glucose, Cu(I) is electrochemically oxidized to generate Cu(II), and the resultant Cu(II) is spontaneously reduced back to Cu(I) by glucose, achieving the sustained Cu(I)/Cu(II) redox cycles. This study provides profound insights into the catalytic mechanism for nonenzymatic glucose sensing, which provides great potential guidance for a rational design of advanced catalysts in the future.
Collapse
|
5
|
A new formulation of Ni/Zn bi-metallic nanocomposite and evaluation of its applications for pollution removal, photocatalytic, electrochemical sensing, and anti-breast cancer. ENVIRONMENTAL RESEARCH 2023; 233:116462. [PMID: 37352956 DOI: 10.1016/j.envres.2023.116462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 06/17/2023] [Accepted: 06/17/2023] [Indexed: 06/25/2023]
Abstract
Nanocomposites have gained attention due to their variety of applications in different fields. In this research, we have reported a green synthesis of a bi-metallic nanocomposite of nickel and zinc using an aqueous extract of Citrus sinensis in the presence of chitosan (Ni/Zn@orange/chitosan). The nanocomposite was characterized using different techniques. We have examined various applications for Ni/Zn@orange/chitosan. The NPs were manufactured in spherical morphology with a particle range size of 17.34-90.51 nm. Ni/Zn@orange/chitosan showed an acceptable ability to remove dyes of Congo red and methyl orange from an aqueous solution after 80 min furthermore, it uptaking the drug mefenamic acid from a solution. Ni/Zn@orange/chitosan also exhibited great photocatalytic activity in synthesizing benzimidazole using benzyl alcohol and o-phenylenediamine. Ni/Zn@orange/chitosan was found as a potent electrochemical sensor to determine glucose. In the molecular and cellular section of the current research, the cells with composite nanoparticles were studied by MTT way about the anti-breast adenocarcinoma potentials malignant cell lines. The IC50 of composite nanoparticles were 320, 460, 328, 500, 325, 379, 350, and 396 μg/mL concering RBA, NMU, SK-BR-3, CAMA-1, MCF7, AU565, MDA-MB-468, and Hs 281.T breast adenocarcinoma cell lines, respectively. The results revealed the newly synthesized nanocomposite is a potent photocatalyst, dye pollution removal agent, and an acceptable new drug to treat breast cancer.
Collapse
|
6
|
Pyridine-Regulated Lamellar Nickel-Based Metal-Organic Framework (Ni-MOF) for Nonenzymatic Electrochemical Glucose Sensor. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2304102. [PMID: 37470100 PMCID: PMC10520646 DOI: 10.1002/advs.202304102] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 07/09/2023] [Indexed: 07/21/2023]
Abstract
2D metal-organic frameworks (MOFs) are considered as promising electrochemical sensing materials and have attracted a lot of attention in recent years. Compared with bulk MOFs, the construction of 2D MOFs can increase the exposure of active sites by obtaining a larger surface area ratio. Herein, a facile one-pot hydrothermal synthesis of pyridine-regulated lamellar Ni-MOFs with ultrathin and well-defined 2D morphology is described. Compared with the bulk structure, the 2D lamellar Ni-MOF has higher surface area and active site density, showing better electrochemical glucose sensing performance. The 2D lamellar Ni-MOF exhibits a fast amperometric response of less than 3 s and a high sensitivity of 907.54 µA mm-1 cm-2 toward glucose with a wide linear range of 0.5-2665.5 µm. Furthermore, the 2D lamellar Ni-MOF also possesses excellent stability and reproducibility, and can be used to detect glucose with high accuracy and reliability in different environments.
Collapse
|
7
|
Feather-like Gold Nanostructures Anchored onto 3D Mesoporous Laser-Scribed Graphene: A Highly Sensitive Platform for Enzymeless Glucose Electrochemical Detection in Neutral Media. BIOSENSORS 2023; 13:678. [PMID: 37504077 PMCID: PMC10377420 DOI: 10.3390/bios13070678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 06/16/2023] [Accepted: 06/21/2023] [Indexed: 07/29/2023]
Abstract
The authors present a novel sensing platform for a disposable electrochemical, non-enzymatic glucose sensor strip at physiological pH. The sensing material is based on dendritic gold nanostructures (AuNs) resembling feather branches, which are electrodeposited onto a laser-scribed 3D graphene electrode (LSGE). The LSGEs were fabricated via a one-step laser scribing process on a commercially available polyimide sheet. This study investigates several parameters that influence the morphology of the deposited Au nanostructures and the catalytic activity toward glucose electro-oxidation. The electrocatalytic activity of the AuNs-LSGE was evaluated using cyclic voltammetry (CV), linear sweep voltammetry (LSV), and amperometry and was compared to commercially available carbon electrodes prepared under the same electrodeposition conditions. The sensor demonstrated good stability and high selectivity of the amperometric response in the presence of interfering agents, such as ascorbic acid, when a Nafion membrane was applied over the electrode surface. The proposed sensing strategy offers a wide linear detection range, from 0.5 to 20 mM, which covers normal and elevated levels of glucose in the blood, with a detection limit of 0.21 mM. The AuNs-LSGE platform exhibits great potential for use as a disposable glucose sensor strip for point-of-care applications, including self-monitoring and food management. Its non-enzymatic features reduce dependence on enzymes, making it suitable for practical and cost-effective biosensing solutions.
Collapse
|
8
|
Nickel Oxy-Hydroxy/Multi-Wall Carbon Nanotubes Film Coupled with a 3D-Printed Device as a Nonenzymatic Glucose Sensor. BIOSENSORS 2023; 13:646. [PMID: 37367011 DOI: 10.3390/bios13060646] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 06/07/2023] [Accepted: 06/09/2023] [Indexed: 06/28/2023]
Abstract
A rapid and simple method for the amperometric determination of glucose using a nanocomposite film of nickel oxyhydroxide and multi-walled carbon nanotube (MWCNTs) was evaluated. The NiHCF)/MWCNT electrode film was fabricated using the liquid-liquid interface method, and it was used as a precursor for the electrochemical synthesis of nickel oxy-hydroxy (Ni(OH)2/NiOOH/MWCNT). The interaction between nickel oxy-hydroxy and the MWCNTs provided a film that is stable over the electrode surface, with high surface area and excellent conductivity. The nanocomposite presented an excellent electrocatalytic activity for the oxidation of glucose in an alkaline medium. The sensitivity of the sensor was found to be 0.0561 μA μmol L-1, and a linear range from 0.1 to 150 μmol L-1 was obtained, with a good limit of detection (0.030 μmol L-1). The electrode exhibits a fast response (150 injections h-1) and a sensitive catalytic performance, which may be due to the high conductivity of MWCNT and the increased active surface area of the electrode. Additionally, a minimal difference in the slopes for ascending (0.0561 µA µmol L-1) and descending (0.0531 µA µmol L-1) was observed. Moreover, the sensor was applied to the detection of glucose in artificial plasma blood samples, achieving values of 89 to 98% of recovery.
Collapse
|
9
|
Progress on the influence of non-enzymatic electrodes characteristics on the response to glucose detection: a review (2016–2022). REV CHEM ENG 2023. [DOI: 10.1515/revce-2022-0058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
Abstract
Abstract
Glucose sensing devices have experienced significant progress in the last years in response to the demand for cost-effective monitoring. Thus, research efforts have been focused on achieving reliable, selective, and sensitive sensors able to monitor the glucose level in different biofluids. The development of enzyme-based devices is challenged by poor stability, time-consuming, and complex purification procedures, facts that have given rise to the synthesis of enzyme-free sensors. Recent advances focus on the use of different components: metal-organic frameworks (MOFs), carbon nanomaterials, or metal oxides. Motivated by this topic, several reviews have been published addressing the sensor materials and synthesis methods, gathering relevant information for the development of new nanostructures. However, the abundant information has not concluded yet in commercial devices and is not useful from an engineering point of view. The dependence of the electrode response on its physico-chemical nature, which would determine the selection and optimization of the materials and synthesis method, remains an open question. Thus, this review aims to critically analyze from an engineering vision the existing information on non-enzymatic glucose electrodes; the analysis is performed linking the response in terms of sensitivity when interferences are present, stability, and response under physiological conditions to the electrode characteristics.
Collapse
|
10
|
The synergistic effect of lamellar cobalt phosphate and sodium metaborate hydrate improves the flame retardancy of epoxy resin. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.129842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
11
|
Instantaneous synthesis and full characterization of organic-inorganic laccase-cobalt phosphate hybrid nanoflowers. Sci Rep 2022; 12:9297. [PMID: 35662266 PMCID: PMC9165545 DOI: 10.1038/s41598-022-13490-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 05/25/2022] [Indexed: 01/10/2023] Open
Abstract
A novel approach termed the "concentrated method" was developed for the instant fabrication of laccase@Co3(PO4)2•hybrid nanoflowers (HNFs). The constructed HNFs were obtained by optimizing the concentration of cobalt chloride and phosphate buffer to reach the highest activity recovery. The incorporation of 30 mM CoCl2 and 160 mM phosphate buffer (pH 7.4) resulted in a fast anisotropic growth of the nanomaterials. The purposed method did not involve harsh conditions and prolonged incubation of precursors, as the most reported approaches for the synthesis of HNFs. The catalytic efficiency of the immobilized and free laccase was 460 and 400 M−1S−1, respectively. Also, the enzymatic activity of the prepared biocatalyst was 113% of the free enzyme (0.5 U mL−1). The stability of the synthesized HNFs was enhanced by 400% at pH 6.5–9.5 and the elevated temperatures. The activity of laccase@Co3(PO4)2•HNFs declined to 50% of the initial value after 10 reusability cycles, indicating successful immobilization of the enzyme. Structural studies revealed a 32% increase in the α-helix content after hybridization with cobalt phosphate, which improved the activity and stability of the immobilized laccase. Furthermore, the fabricated HNFs exhibited a considerable ability to remove moxifloxacin as an emerging pollutant. The antibiotic (10 mg L−1) was removed by 24% and 75% after 24 h through adsorption and biodegradation, respectively. This study introduces a new method for synthesizing HNFs, which could be used for the fabrication of efficient biocatalysts, biosensors, and adsorbents for industrial, biomedical, and environmental applications.
Collapse
|
12
|
Nanoporous Cauliflower-like Pd-Loaded Functionalized Carbon Nanotubes as an Enzyme-Free Electrocatalyst for Glucose Sensing at Neutral pH: Mechanism Study. SENSORS 2022; 22:s22072706. [PMID: 35408320 PMCID: PMC9002983 DOI: 10.3390/s22072706] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 03/28/2022] [Accepted: 03/29/2022] [Indexed: 02/04/2023]
Abstract
In this work, we propose a novel functionalized carbon nanotube (f-CNT) supporting nanoporous cauliflower-like Pd nanostructures (PdNS) as an enzyme-free interface for glucose electrooxidation reaction (GOR) in a neutral medium (pH 7.4). The novelty resides in preparing the PdNS/f-CNT biomimetic nanocatalyst using a cost-effective and straightforward method, which consists of drop-casting well-dispersed f-CNTs over the Screen-printed carbon electrode (SPCE) surface, followed by the electrodeposition of PdNS. Several parameters affecting the morphology, structure, and catalytic properties toward the GOR of the PdNS catalyst, such as the PdCl2 precursor concentration and electrodeposition conditions, were investigated during this work. The electrochemical behavior of the PdNS/f-CNT/SPCE toward GOR was investigated through Cyclic Voltammetry (CV), Linear Sweep Voltammetry (LSV), and amperometry. There was also a good correlation between the morphology, structure, and electrocatalytic activity of the PdNS electrocatalyst. Furthermore, the LSV response and potential-pH diagram for the palladium–water system have enabled the proposal for a mechanism of this GOR. The proposed mechanism would be beneficial, as the basis, to achieve the highest catalytic activity by selecting the suitable potential range. Under the optimal conditions, the PdNS/f-CNT/SPCE-based biomimetic sensor presented a wide linear range (1–41 mM) with a sensitivity of 9.3 µA cm−2 mM−1 and a detection limit of 95 µM (S/N = 3) toward glucose at a detection potential of +300 mV vs. a saturated calomel electrode. Furthermore, because of the fascinating features such as fast response, low cost, reusability, and poison-free characteristics, the as-proposed electrocatalyst could be of great interest in both detection systems (glucose sensors) and direct glucose fuel cells.
Collapse
|
13
|
Highly sensitive and selective non-enzymatic measurement of glucose using arraying of two separate sweat sensors at physiological pH. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
14
|
3D Modeling of Silver Doped ZrO 2 Coupled Graphene-Based Mesoporous Silica Quaternary Nanocomposite for a Nonenzymatic Glucose Sensing Effects. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:193. [PMID: 35055212 PMCID: PMC8779333 DOI: 10.3390/nano12020193] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 12/27/2021] [Accepted: 01/04/2022] [Indexed: 01/27/2023]
Abstract
We described the novel nanocomposite of silver doped ZrO2 combined graphene-based mesoporous silica (ZrO2-Ag-G-SiO2,) in bases of low-cost and self-assembly strategy. Synthesized ZrO2-Ag-G-SiO2 were characterized through X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectrometry (EDX), transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM), Raman spectroscopy, Nitrogen adsorption-desorption isotherms, X-ray photoelectron spectroscopy (XPS), and Diffuse Reflectance Spectroscopy (DRS). The ZrO2-Ag-G-SiO2 as an enzyme-free glucose sensor active material toward coordinate electro-oxidation of glucose was considered through cyclic voltammetry in significant electrolytes, such as phosphate buffer (PBS) at pH 7.4 and commercial urine. Utilizing ZrO2-Ag-G-SiO2, glucose detecting may well be finished with effective electrocatalytic performance toward organically important concentrations with the current reaction of 9.0 × 10-3 mAcm-2 and 0.05 mmol/L at the lowest potential of +0.2 V, thus fulfilling the elemental prerequisites for glucose detecting within the urine. Likewise, the ZrO2-Ag-G-SiO2 electrode can be worked for glucose detecting within the interferometer substances (e.g., ascorbic corrosive, lactose, fructose, and starch) in urine at proper pH conditions. Our results highlight the potential usages for qualitative and quantitative electrochemical investigation of glucose through the ZrO2-Ag-G-SiO2 sensor for glucose detecting within the urine concentration.
Collapse
|
15
|
|
16
|
Recent Advances in Non-Enzymatic Glucose Sensors Based on Metal and Metal Oxide Nanostructures for Diabetes Management- A Review. Front Chem 2021; 9:748957. [PMID: 34631670 PMCID: PMC8493127 DOI: 10.3389/fchem.2021.748957] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 09/09/2021] [Indexed: 01/23/2023] Open
Abstract
There is an undeniable growing number of diabetes cases worldwide that have received widespread global attention by many pharmaceutical and clinical industries to develop better functioning glucose sensing devices. This has called for an unprecedented demand to develop highly efficient, stable, selective, and sensitive non-enzymatic glucose sensors (NEGS). Interestingly, many novel materials have shown the promising potential of directly detecting glucose in the blood and fluids. This review exclusively encompasses the electrochemical detection of glucose and its mechanism based on various metal-based materials such as cobalt (Co), nickel (Ni), zinc (Zn), copper (Cu), iron (Fe), manganese (Mn), titanium (Ti), iridium (Ir), and rhodium (Rh). Multiple aspects of these metals and their oxides were explored vis-à-vis their performance in glucose detection. The direct glucose oxidation via metallic redox centres is explained by the chemisorption model and the incipient hydrous oxide/adatom mediator (IHOAM) model. The glucose electrooxidation reactions on the electrode surface were elucidated by equations. Furthermore, it was explored that an effective detection of glucose depends on the aspect ratio, surface morphology, active sites, structures, and catalytic activity of nanomaterials, which plays an indispensable role in designing efficient NEGS. The challenges and possible solutions for advancing NEGS have been summarized.
Collapse
|
17
|
Developments of the Electroactive Materials for Non-Enzymatic Glucose Sensing and Their Mechanisms. ELECTROCHEM 2021. [DOI: 10.3390/electrochem2020025] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
A comprehensive review of the electroactive materials for non-enzymatic glucose sensing and sensing devices has been performed in this work. A general introduction for glucose sensing, a facile electrochemical technique for glucose detection, and explanations of fundamental mechanisms for the electro-oxidation of glucose via the electrochemical technique are conducted. The glucose sensing materials are classified into five major systems: (1) mono-metallic materials, (2) bi-metallic materials, (3) metallic-oxide compounds, (4) metallic-hydroxide materials, and (5) metal-metal derivatives. The performances of various systems within this decade have been compared and explained in terms of sensitivity, linear regime, the limit of detection (LOD), and detection potentials. Some promising materials and practicable methodologies for the further developments of glucose sensors have been proposed. Firstly, the atomic deposition of alloys is expected to enhance the selectivity, which is considered to be lacking in non-enzymatic glucose sensing. Secondly, by using the modification of the hydrophilicity of the metallic-oxides, a promoted current response from the electro-oxidation of glucose is expected. Lastly, by taking the advantage of the redistribution phenomenon of the oxide particles, the usage of the noble metals is foreseen to be reduced.
Collapse
|
18
|
Sulfonated glycosaminoglycan bioinspired carbon dots for effective cellular labelling and promotion of the differentiation of mesenchymal stem cells. J Mater Chem B 2021; 8:5655-5666. [PMID: 32500905 DOI: 10.1039/d0tb00795a] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Although carbon dots (CDs) have been synthesized and applied in a variety of biological fields, such as disease diagnosis and gene/drug delivery, the exploration of facile bioinspired synthesis and applications of CDs is still of great significance. Particularly, recent increasing research has clearly confirmed that nanomaterials can affect a series of physiological behaviors and functions of mesenchymal stem cells (MSCs) (e.g., differentiation and pluripotency). Therefore, it is very important to develop multifunctional nanomaterials to simultaneously realize the cellular labelling and regulation of MSC behaviors in practical applications. Herein, sulfonated glycosaminoglycan-bioinspired CDs as bi-functional nanomaterials were ingeniously designed for cellular imaging and promoting the differentiation of rat bone MSCs (rBMSCs) in different culture media, which simultaneously met the two fundamental requirements in the field of MSC-based treatments (e.g., precisely directing the differentiation of MSCs and effective cellular labeling). These bifunctional CDs were successfully prepared via one-pot hydrothermal synthesis by using d-glucosamine hydrochloride (GA·HCl) and sodium p-styrenesulfonate (NaSS) as the reactants. The synthesized CDs with a uniform particle size (around 4 nm) dispersed well in aqueous solutions and exhibited remarkable fluorescence stability under different conditions. Additionally, cell viability and proliferation results demonstrated that the CDs possessed good biocompatibility, having negligible effects on the self-renewal potential of rBMSCs. The as-prepared CDs presented a cytoplasmatic distribution after being ingested by rBMSCs; thus, they are particularly suitable for cellular imaging. More importantly, the addition of CDs to osteogenic and chondrogenic induction media (OIM and CIM), respectively, was capable of effectively promoting the osteogenic and chondrogenic differentiation of rBMSCs due to the generation of reactive oxygen species (ROS) while having no influence on their pluripotency. In brief, this study not only implements a cellular labeling method based on CDs that were synthesized by a biomimicking strategy, but also paves a new way to regulate the differentiation of MSCs by designing multifunctional nanomaterials; this will enable the extensive development of facile synthesis methods and new applications of CDs and will also provide some research foundations for MSC-based fields.
Collapse
|
19
|
2D metal azolate framework as nanozyme for amperometric detection of glucose at physiological pH and alkaline medium. Mikrochim Acta 2021; 188:77. [PMID: 33566156 DOI: 10.1007/s00604-021-04737-w] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 01/29/2021] [Indexed: 12/19/2022]
Abstract
The synthesis of Co-based two-dimensional (2D) metal azolate framework nanosheets (MAF-5-CoII NS) is described using a simple hydrothermal method. The product was isostructural to MAF-5 (Zn). The as-prepared MAF-5-CoII NS exhibited high surface area (1155 m2/g), purity, and crystallinity. The MAF-5-CoII NS-modified screen-printed electrode (MAF-5-CoII NS/SPE) was used for nonenzymatic detection of glucose in diluted human blood plasma (BP) samples with phosphate buffer saline (PBS, pH 7.4) and NaOH (0.1 M, pH 13.0) solutions. The MAF-5-CoII NS nanozyme displayed good redox activity in both neutral and alkaline media with the formation of CoII/CoIII redox pair, which induced the catalytic oxidation of glucose. Under the optimized detection potential, the sensor presented a chronoamperometric current response for the oxidation of glucose with two wide concentration ranges in PBS-diluted (62.80 to 180 μM and 305 to 8055 μM) and NaOH-diluted (58.90 to 117.6 μM and 180 to 10,055 μM) BP samples, which were within the limit of blood glucose levels of diabetic patients before (4.4-7.2 mM) and after (10 mM) meals (recommended by the American Diabetes Association). The sensor has a limit of detection of ca. 0.25 and 0.05 μM, respectively, and maximum sensitivity of ca. 36.55 and 1361.65 mA/cm2/mM, respectively, in PBS- and NaOH-diluted BP samples. The sensor also displayed excellent stability in the neutral and alkaline media due to the existence of hydrophobic linkers (2-ethyl imidazole) in the MAF-5-CoII NS, good repeatability and reproducibility, and interference-free signals. Thus, MAF-5-CoII NS is a promising nanozyme for the development of the disposable type of sensor for glucose detection in human body fluids. Graphical abstract.
Collapse
|
20
|
Green fabrication of Cu/rGO decorated SWCNT buckypaper as a flexible electrode for glucose detection. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 120:111757. [PMID: 33545898 DOI: 10.1016/j.msec.2020.111757] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 10/27/2020] [Accepted: 11/21/2020] [Indexed: 12/17/2022]
Abstract
As a paper-like membrane composed of single-walled carbon nanotube (SWCNT), buckypaper possesses high conductivity, ideal flexibility, large surface area, great thermal/chemical stability and biocompatibility, which has manifested its potential as an alternative support material. However, due to the lack of defects, high quality SWCNT synthesized by arc-discharge method is difficult to be modified with metal nanoparticles for electro-catalysis. In this paper, a novel green strategy has been developed to fabricate SWCNT buckypaper decorated with Cu/reduced graphene oxide (Cu/rGO-BP) for the first time, in which graphene oxide functions as the intermediate between SWCNT and Cu nanoparticles. The fabricated Cu/rGO-BP was applied as a flexible electrode for electrochemical glucose detection. The electrode exhibited excellent electro-catalytic activity for glucose oxidation. The sensor based on Cu/rGO-BP performed a high upper limit of linear range (25 mM), which is close to commercial glucose sensors. The proposed strategy for Cu/rGO-BP fabrication can be extended to modify buckypaper with other metal or metal oxide nanoparticles, and thus opens an innovative route to potential practical applications of flexible buckypaper in wearable bioelectronics.
Collapse
|
21
|
Metal–Organic Framework‐Derived Nickel/Cobalt‐Based Nanohybrids for Sensing Non‐Enzymatic Glucose. ChemElectroChem 2020. [DOI: 10.1002/celc.202001135] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
22
|
Core-shell MOF@MOF composites for sensitive nonenzymatic glucose sensing in human serum. Anal Chim Acta 2020; 1110:35-43. [DOI: 10.1016/j.aca.2020.02.023] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 01/22/2020] [Accepted: 02/10/2020] [Indexed: 02/07/2023]
|
23
|
Role of Transition Metals in Layered Double Hydroxides for Differentiating the Oxygen Evolution and Nonenzymatic Glucose Sensing. ACS APPLIED MATERIALS & INTERFACES 2020; 12:6193-6204. [PMID: 31916748 DOI: 10.1021/acsami.9b18186] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Layered double hydroxides (LDH) belong to the class of two-dimensional materials having a wide variety of applications ranging from energy storage to catalysis. Often, these materials when used for nonenzymatic electrochemical glucose sensing tend to be interfering with oxygen evolution reaction (OER), resulting in overestimation of the glucose. Herein, to address this, NiFe-based LDH were selected because of their ability to vary the metal ratios. The synthesized LDH have been characterized using various spectroscopic and microscopic techniques. Among the LDH synthesized, Ni4Fe-LDH have been able to differentiate the glucose oxidation potential and the onset potential of OER with minimum interference. The Ni4Fe-LDH sensor shows a sensitivity of 20.43 μA mM-1 cm-2 in the linear range of 0-4 mM concentrations. To further enhance the sensitivity, composites of reduced graphene oxide (rGO) have been synthesized in situ, and the Ni4Fe/rGO5 composites have shown an increased sensitivity of 176.8 μA mM-1 cm-2 attributed to the charge-transfer interactions. To understand the experimental observations, detailed computational studies have been carried out to study the effect of the electronic structure on the metal ratios of the LDH and its role in differentiating glucose sensing and the oxygen evolution reaction. Along with this, theoretical calculations are also carried out on LDH-graphene composites to study the charge-transfer interactions.
Collapse
|
24
|
Controlled synthesis of flower-like cobalt phosphate microsheet arrays supported on Ni foam as a highly efficient 3D integrated anode for non-enzymatic glucose sensing. Inorg Chem Front 2020. [DOI: 10.1039/c9qi00948e] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
CoPO MA/NF was synthesized in a controlled way and utilized as an efficient 3D integrated electrode for enzyme-free glucose sensing.
Collapse
|
25
|
Nanoengineering multifunctional hybrid interfaces using adhesive glycogen nanoparticles. J Mater Chem B 2020; 8:4851-4858. [DOI: 10.1039/d0tb00299b] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Amphiphilic phytoglycogen nanoparticles are used as building blocks for engineering multifunctional hybrid films with catalytic and sensing properties.
Collapse
|
26
|
MOF‐Derived Spinel NiCo
2
O
4
Hollow Nanocages for the Construction of Non‐enzymatic Electrochemical Glucose Sensor. ELECTROANAL 2019. [DOI: 10.1002/elan.201900558] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
27
|
Carbon fibers coated with urchin-like copper sulfide for nonenzymatic voltammetric sensing of glucose. Mikrochim Acta 2019; 186:807. [PMID: 31745655 DOI: 10.1007/s00604-019-3915-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Accepted: 10/11/2019] [Indexed: 11/28/2022]
Abstract
Urchin-like CuS was grown on xanthan gum-derived carbon nanofibers to obtain a sensor for enzyme-free electrochemical sensing of glucose. The unique nanostructure of the sensor provides a large specific surface, more electrocatalytically active sites, and high electrical conductivity. The voltammetric response to glucose, best measured at around 57 mV (vs. Ag/AgCl (E/V)) in 0.1 M NaOH solution, covers two linear ranges, one from 0.1-125 μM, another from 0.16 to 1.2 mM. The sensitivity is quite high (23.7 μA mM-1 cm-2), and the detection limit is low (19 nM at S/N = 3). The sensor has high selectivity against potentially interfering molecules such as fructose, appreciable operational stability, excellent durability, and good repeatability (with relative standard deviations of 2.3%). It was successfully applied to the determination of glucose in diluted serum samples. Graphical abstractSchematic representation of electrochemical detection of glucose based on the use of a screen printed carbon electrode (SPCE) modified with CuS and xanthan gum-derived carbon nanofibers (XGCNFs).
Collapse
|
28
|
Facile Non-Enzymatic Electrochemical Sensing for Glucose Based on Cu 2O-BSA Nanoparticles Modified GCE. SENSORS (BASEL, SWITZERLAND) 2019; 19:E2824. [PMID: 31238594 PMCID: PMC6631518 DOI: 10.3390/s19122824] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 06/20/2019] [Accepted: 06/21/2019] [Indexed: 12/12/2022]
Abstract
Transition-metal nanomaterials are very important to non-enzymatic glucose sensing because of their excellent electrocatalytic ability, good selectivity, the fact that they are not easily interfered with by chloride ion (Cl-), and low cost. However, the linear detection range needs to be expanded. In this paper, Cu2O-bovine serum albumin (BSA) core-shell nanoparticles (NPs) were synthesized for the first time in air at room temperature by a facile and green route. The structure and morphology of Cu2O-BSA NPs were characterized. The as-prepared Cu2O-BSA NPs were used to modify the glassy carbon electrode (GCE) in a Nafion matrix. By using cyclic voltammetry (CV), the influence from scanning speed, concentration of NaOH, and load of Cu2O-BSA NPs for the modified electrodes was probed. Cu2O-BSA NPs showed direct electrocatalytic activity for the oxidation of glucose in 50 mM NaOH solution at 0.6 V. The chronoamperometry result showed this constructing sensor in the detection of glucose with a lowest detection limit of 0.4 μM, a linear detection range up to 10 mM, a high sensitivity of 1144.81 μAmM-1cm-2 and reliable anti-interference property to Cl-, uric acid (UA), ascorbic acid (AA), and acetaminophen (AP). Cu2O-BSA NPs are promising nanostructures for the fabrication of non-enzymatic glucose electrochemical sensing devices.
Collapse
|
29
|
MOF-derived 3D leaf-like CuCo oxide arrays as an efficient catalyst for highly sensitive glucose detection. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.04.039] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
30
|
Facile Fabrication of NiO-Decorated Double-Layer Single-Walled Carbon Nanotube Buckypaper for Glucose Detection. ACS APPLIED MATERIALS & INTERFACES 2019; 11:10856-10861. [PMID: 30802407 DOI: 10.1021/acsami.9b00803] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A novel NiO-decorated flexible buckypaper (NiO-BP) was fabricated by a simple and scalable vacuum filtration method for electrochemical detection of glucose. The NiO-BP consists of two layers: one side is composed of purified single-walled carbon nanotubes, serving as the supporting layer, whereas the other side comprises NiO-loaded single-walled carbon nanotubes, serving as the catalyst layer. The morphology and structure of NiO-BP were characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction and Raman spectroscopy. The fabricated NiO-BP was applied to the electrochemical detection of glucose. Under optimized conditions, the sensor exhibited a wide linear range of 0.1-9 mM for the determination of glucose with high sensitivity (2701 μA mM-1 cm-2) and a short response time (<2.5 s). The present work reveals that the buckypaper with a unique double-layer structure is promising for wearable biosensors.
Collapse
|
31
|
A review of the advanced developments of electrochemical sensors for the detection of toxic and bioactive molecules. Inorg Chem Front 2019. [DOI: 10.1039/c9qi00602h] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The recent developments made regarding the novel, cost-effective, and environmentally friendly nanocatalysts for the electrochemical sensing of biomolecules, pesticides, nitro compounds and heavy metal ions are discussed in this review article.
Collapse
|