Béal L, Navel V, Pereira B, Magnier F, Watson SL, Baker JS, Chiambaretta F, Dutheil F. Efficacy of Thin and Ultrathin Descemet Stripping Automated Endothelial Keratoplasty and Influence of Graft Thickness on Postoperative Outcomes: Systematic Review and Meta-analysis.
Am J Ophthalmol 2022;
240:170-86. [PMID:
35346623 DOI:
10.1016/j.ajo.2022.03.022]
[Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 03/08/2022] [Accepted: 03/17/2022] [Indexed: 12/29/2022]
Abstract
PURPOSE
To conduct a systematic review and meta-analysis on the efficacy of thin and ultrathin Descemet stripping automated endothelial keratoplasty (T-DSAEK and UT-DSAEK, with graft thickness <130 and <100 µm, respectively), depending on graft thickness.
DESIGN
Systematic review and meta-analysis.
METHOD
PubMed, Cochrane Library, Embase, ClinicalTrials.gov, and ScienceDirect databases were searched until October 1, 2021. We computed random-effect meta-analysis on postoperative outcomes of T/UT-DSAEK, stratified by graft thickness (<80 μm, 80-100 μm, and 100-130 μm). The main postoperative outcome was visual acuity (logarithm of the minimum angle of resolution [logMAR]). Secondary outcomes were pachymetry (μm), endothelial cell count (cell/mm2), spherical equivalent (diopter [D]), rebubbling rate (%), and rejection rate (%). Meta-regressions compared postoperative outcomes depending on graft thickness and search for putative confusion factors.
RESULTS
We included 47 articles for a total of 2141 eyes of 2040 patients. T/UT-DSAEK globally improved visual acuity (effect size = -0.38 logMAR [95% confidence interval {CI} -0.46 to -0.30 logMAR]), without difference depending on graft thickness. Overall, pachymetry improved (-60.6 µm [95% CI -101 to -19.7 µm]), endothelial cell count decreased (-1039 cells/mm2 [95% CI -1209 to -868 cells/mm2), spherical equivalent resulted in a hyperopic shift (0.74 D [95% CI -0.50 to 1.97 D), the graft rejection rate was 0.2% (95% CI -0.1% to 0.4%), and the rebubbling rate was 8.7% (95% CI 6.8%-10.5%). Grafts >100 μm induced a hyperopic shift. Metaregressions did not demonstrate differences between the 3 groups (<80 μm, 80-100 μm, or 100-130 μm) in any outcomes.
CONCLUSION
All T/UT-DSAEK thickness groups provided similar visual acuity, pachymetry, endothelial cell count, rejection rate, and rebubbling rate regardless of graft thickness. A hyperopic shift was induced by grafts >100 μm.
Collapse