Wu X, Zhao D, Hu W, Zheng Z, Zha S, Zhang Q, Hu K. Randomised, controlled crossover trial of intermittent and continuous transcutaneous electrical stimulation of the genioglossus muscle for obstructive sleep apnoea.
Thorax 2023;
78:713-720. [PMID:
36690924 DOI:
10.1136/thorax-2021-218277]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 08/13/2022] [Indexed: 01/25/2023]
Abstract
PURPOSE
Continuous transcutaneous electrical stimulation (CTES) of the genioglossus muscle may benefit patients with obstructive sleep apnoea (OSA). However, the therapeutic value of intermittent transcutaneous electrical stimulation (ITES) for OSA is unclear.
METHODS
This was a randomised, controlled, crossover study to compare the effects of ITES and CTES of the genioglossus muscle. Over three single-night sessions, participants were alternately subjected to three genioglossus stimulation modalities during sleep (sham, CTES and ITES). The apnoea-hypopnoea index (AHI) and oxygen desaturation index (ODI) were used for OSA diagnosis and to evaluate efficacy. A responder was defined as an individual with a ≥50% reduction in AHI together with <10 AHI events per hour and/or an ODI reduction of ≥25% between sham stimulation and electrical stimulation nights.
RESULTS
Fifteen men with OSA completed the study. Compared with sham, the median AHI with ITES decreased by 13.3 events/hour (95% CI 3.1 to 23.5, p=0.030) and by 7.3 events/hour (95% CI -3.9 to 18.5, p=0.825) with CTES. The median ODI was reduced by 9.25 events/hour (95% CI 0.5 to 18.0) with ITES and 3.3 events/hour (95% CI -5.6 to 12.2) with CTES; however, there was no significant difference between groups. Furthermore, ITES outperformed CTES with respect to longest apnoea duration (median (95% CI), 9.5 (0.0 to 19.0), p=0.011)) and the highest sleep efficiency (12.2 (2.7 to 21.7), p=0.009). Of the 15 participants, 8 responded to ITES and 3 responded to CTES (p=0.058), of whom all eight cases and two out of three cases had ODIs <5 events/hour, respectively. All participants tolerated ITES well.
CONCLUSIONS
ITES improved upper airway obstruction in patients with OSA, suggesting that further prospective validation of the intermittent approach is warranted.
TRIAL REGISTRATION NUMBER
ChiCTR2100050138.