1
|
Francica A, Benvegnù L, San Biagio L, Tropea I, Luciani GB, Faggian G, Onorati F. Ten-year clinical and echocardiographic follow-up of third-generation biological prostheses in the aortic position. J Thorac Cardiovasc Surg 2024; 167:1705-1713.e8. [PMID: 36404144 DOI: 10.1016/j.jtcvs.2022.10.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 10/12/2022] [Accepted: 10/13/2022] [Indexed: 11/11/2022]
Abstract
OBJECTIVES PERIMOUNT Magna Ease (Carpentier-Edwards; PME) prostheses have been widely implanted during the past decade for aortic valve replacement (AVR). Although promising results at midterm follow-up were reported, long-term outcome has yet to be confirmed. On this study we aimed to evaluate long-term results in terms of structural valve degeneration (SVD), major clinical outcomes, long-term hemodynamic valve performance, and left ventricular remodeling. METHODS From 2010 to 2012, 689 consecutive patients underwent AVR with PME. Complete clinical 10-year follow-up was obtained. The degree of SVD was categorized on the basis of the latest guidelines. Echocardiographic data were analyzed at 1, 5, and 10 years. Competing risk analysis was performed for major events. Cumulative incidence of SVD, reoperation, and endocarditis were also assessed according to prosthetic sizes (19-21-23 mm vs 25-27-29 mm) and age (<65 vs 65-75 vs >75 years old). RESULTS The overall cumulative incidence reported for SVD ≥2 and reoperation were 3.6% and 1.9% at 10 years, respectively. An early left ventricular reverse remodeling was noted after implantation and confirmed at follow-up. Patients younger than 65 years showed higher cumulative incidence of SVD ≥2 at 10 years compared with patients aged 65 to 75 and older than 75 years (9.7% vs 2.6% vs 2.7%; P = .013), as well as of redo AVR (7.8% vs 3.3% vs 0.4%; P = .002). There was no difference in terms of SVD and redo AVR for different prosthetic size categories (P > .05). The risk of endocarditis was similar among age and size groups. CONCLUSIONS PME provides very good durability at long-term and could be considered one of the high performing third-generation bioprostheses for AVR.
Collapse
Affiliation(s)
- Alessandra Francica
- Division of Cardiac Surgery, Departments of Surgery, Dentistry, Paediatrics, and Gynaecology, University of Verona Medical School, Verona, Italy.
| | - Luciana Benvegnù
- Division of Cardiac Surgery, Departments of Surgery, Dentistry, Paediatrics, and Gynaecology, University of Verona Medical School, Verona, Italy
| | - Livio San Biagio
- Division of Cardiac Surgery, Departments of Surgery, Dentistry, Paediatrics, and Gynaecology, University of Verona Medical School, Verona, Italy
| | - Ilaria Tropea
- Division of Cardiac Surgery, Departments of Surgery, Dentistry, Paediatrics, and Gynaecology, University of Verona Medical School, Verona, Italy
| | - Giovanni Battista Luciani
- Division of Cardiac Surgery, Departments of Surgery, Dentistry, Paediatrics, and Gynaecology, University of Verona Medical School, Verona, Italy
| | - Giuseppe Faggian
- Division of Cardiac Surgery, Departments of Surgery, Dentistry, Paediatrics, and Gynaecology, University of Verona Medical School, Verona, Italy
| | - Francesco Onorati
- Division of Cardiac Surgery, Departments of Surgery, Dentistry, Paediatrics, and Gynaecology, University of Verona Medical School, Verona, Italy
| |
Collapse
|
2
|
Netsanet A, Cotton J, Suarez-Pierre A, Hoffman J, Aftab M, Reece B, Rove JY. Cardiac Surgeons Highlight the Need for Innovation Stewardship: Noteworthy in 2022. Semin Cardiothorac Vasc Anesth 2023; 27:136-144. [PMID: 37098029 DOI: 10.1177/10892532231173090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2023]
Abstract
Modern cardiac surgery has rapidly evolved to treat complex cardiovascular disease. This past year boasted noteworthy advances in xenotransplantation, prosthetic cardiac valves, and endovascular thoracic aortic repair. Newer devices often offer incremental design changes while demanding significant cost increases that leave surgeons to decide if the benefit to patients justifies the increased cost. As innovations are introduced, surgeons must continuously aim to harmonize short- and long-term benefits with financial costs). We must also ensure quality patient outcomes while embracing innovations that will advance equitable cardiovascular care.
Collapse
Affiliation(s)
- Adom Netsanet
- Department of Surgery, University of Colorado Anschutz Medical Campus School of Medicine, Aurora, CO, USA
| | - Jake Cotton
- Department of Surgery, University of Colorado Anschutz Medical Campus School of Medicine, Aurora, CO, USA
| | | | - Jordan Hoffman
- Department of Surgery, University of Colorado Anschutz Medical Campus School of Medicine, Aurora, CO, USA
| | - Muhammad Aftab
- Department of Surgery, University of Colorado Anschutz Medical Campus School of Medicine, Aurora, CO, USA
| | - Brett Reece
- Department of Surgery, University of Colorado Anschutz Medical Campus School of Medicine, Aurora, CO, USA
| | - Jessica Y Rove
- University of Colorado - Anschutz Medical Campus, Aurora, CO, USA
| |
Collapse
|
3
|
Francica A, Tonelli F, Rossetti C, Galeone A, Perrone F, Luciani GB, Onorati F. Perimount MAGNA Ease vs. INSPIRIS Resilia Valve: A PS-Matched Analysis of the Hemodynamic Performances in Patients below 70 Years of Age. J Clin Med 2023; 12. [PMID: 36902862 DOI: 10.3390/jcm12052077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 02/23/2023] [Accepted: 03/04/2023] [Indexed: 03/09/2023] Open
Abstract
BACKGROUND During the past decade, the Perimount Magna Ease (PME) bioprosthesis has been implanted worldwide for aortic valve replacement (AVR). Recently, the INSPIRIS Resilia (IR) valve has been introduced as the newest generation of pericardial bioprostheses. However, few data have been reported about patients ≤70 years, and no comparisons in terms of hemodynamic performance between these two bioprostheses have been ever reported. METHODS Patients aged <70 years undergoing AVR were considered for comparison between PME (n = 238) and IR (n = 192). Propensity score (PS) matching was performed by logistic regression with adjustment for eight key baseline variables. The two prostheses were compared in terms of hemodynamic performances up to 3 years postoperatively. Sub-analysis according to prosthetic size-category was accomplished. RESULTS A total of 122 pairs with similar baseline characteristics were obtained from the PS-matching. The two prostheses showed comparable hemodynamic performances at one year (Gmean: 11.3 ± 3.5 mmHg vs. 11.9 ± 5.4 mmHg; p = 0.8) and at 3 years postoperatively (Gmean: 12.2 ± 7.9 mmHg vs. 12.8 ± 5.2 mmHg for; p = 0.3). The sub-analysis of size-category confirmed no statistical differences concerning the hemodynamic performances for each annulus size. CONCLUSIONS This first PS-matched analysis demonstrated that the newly developed IR valve achieves the same safety and efficacy of the PME valve during mid-term follow-up in patients aged <70 years.
Collapse
|
4
|
Bartus K, Bavaria JE, Thourani VH, Xu K, Keuffel EL. Structural hemodynamic valve deterioration durability of RESILIA-tissue versus contemporary aortic bioprostheses. J Comp Eff Res 2023; 12:e220180. [PMID: 36691718 PMCID: PMC10288964 DOI: 10.2217/cer-2022-0180] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Accepted: 01/03/2023] [Indexed: 01/25/2023] Open
Abstract
Aim: Durability of aortic valve replacement is becoming increasingly important. Aortic bioprostheses with RESILIA tissue have demonstrated outstanding outcomes thus far, but only in single-arm studies. Methods: We compared structural valve deterioration (SVD)-related hemodynamic valve deterioration (HVD) of grade ≥2 of RESILIA tissue valves from the COMMENCE trial (n = 689) to those from the PARTNER 2A contemporary AVR arm (n = 936) based upon annual core laboratory echocardiograms through 5 years of follow-up. Results: SVD-related HVD in the COMMENCE and PARTNER 2A cohorts were 1.8 versus 3.5%, respectively (one-sided 95% lower-bound hazard ratio of 0.92; p = 0.07). In propensity-matched cohorts (n = 239), these outcomes were 1.0 versus 4.8%, respectively (one-sided 95% lower-bound hazard ratio of 1.15; p = 0.03). Conclusion: RESILIA tissue-based AVR exhibited reduced SVD-related HVD compared with a contemporary AVR cohort devoid of RESILIA tissue.
Collapse
Affiliation(s)
- Krzysztof Bartus
- Department of Cardiovascular Surgery & Transplantology, Jagiellonian University Medical College, Institute of Cardiology, John Paul II Hospital, Krakow, Poland
| | - Joseph E Bavaria
- Department of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Vinod H Thourani
- Department of Cardiovascular Surgery, Marcus Valve Center, Piedmont Heart Institute, Atlanta, GA, USA
| | - Ke Xu
- Edwards Lifesciences, Irvine, CA, USA
| | | |
Collapse
|
5
|
Tsui S, Rosenbloom M, Abel J, Swanson J, Haverich A, Zacharias J, Schorlemmer G, Cohen G, Moulton M, Lange R. Eight-year outcomes of aortic valve replacement with the Carpentier-Edwards PERIMOUNT Magna Ease valve. J Card Surg 2022; 37:4999-5010. [PMID: 36378942 PMCID: PMC10100054 DOI: 10.1111/jocs.17140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Accepted: 10/29/2022] [Indexed: 11/16/2022]
Abstract
INTRODUCTION The Carpentier-Edwards PERIMOUNT Magna Ease valve is a third-generation bioprosthesis for aortic valve replacement (AVR). This is a postapproval study reporting on its 8-year outcomes. METHODS Adults undergoing AVR with the Magna Ease valve between October 2007 and December 2012 were enrolled for this prospective, nonrandomized, single-arm, and multicenter study. Assessments occurred preoperatively, at hospital discharge, 6 months, 1 year, and annually thereafter for up to 8 years. Outcomes included safety endpoints, hemodynamic performance, and New York Heart Association (NYHA) functional class. RESULTS Of the 258 study patients, 67.5% were in NYHA Class I or II, and 32.5% were in NYHA Class III or IV at baseline. Concomitant procedures were performed in 44.2%. Total follow-up was 1597.6 patient-years, and median follow-up was 7 years (interquartile range: 5.5-8.0 years). Eight years following AVR, the functional class remained improved from baseline with 93.9% in NYHA Class I/II and 6.1% in NYHA Class III; 38 deaths had occurred, 8 of which were valve related; freedom from all-cause mortality was 80.7% (95% confidence intervals: 74.9, 86.4); freedom from valve-related mortality was 95.8% (92.8, 98.8); freedom from reintervention, explant, major bleeding events, and structural valve deterioration was 89.8% (85.1, 94.6), 94.8% (91.7, 97.9), 85.1% (80.0, 90.1), and 90.1% (84.7, 95.4), respectively; effective orifice area was 1.5 ± 0.5 cm2 , the mean gradient was 14.8 ± 8.3 mmHg, and 88.6% of patients had no or trivial aortic regurgitation. CONCLUSIONS This study demonstrated satisfactory safety and sustained hemodynamic and functional improvements at 8 years following AVR with the Magna Ease valve.
Collapse
Affiliation(s)
- Steven Tsui
- Department of Cardiothoracic Surgery and Transplantation, Royal Papworth Hospital, Cambridge, UK
| | - Michael Rosenbloom
- Division of Cardiothoracic Surgery, Cooper University Hospital, Camden, New Jersey, USA
| | - James Abel
- Division of Cardiac and Thoracic Surgery, St Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| | - Jeffrey Swanson
- Providence Heart Valve Clinic, Providence St Vincent's Hospital, Portland, Oregon, USA
| | - Axel Haverich
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Medizinische Hochschule Hannover, Hannover, Germany
| | - Joseph Zacharias
- Department of Cardiothoracic Surgery, Blackpool Victoria Hospital, Blackpool, UK
| | - Gilbert Schorlemmer
- Department of Cardiac, Vascular and Thoracic Surgery, St Mark's Hospital, Salt Lake, Utah, USA
| | - Gideon Cohen
- Department of Surgery, Division of Cardiac Surgery, Sunnybrook Health Sciences Center, North York, Ontario, Canada
| | - Michael Moulton
- Division of Cardiothoracic Surgery, University of Nebraska Medical Center, Omaha, Nebraska, USA
| | - Rüdiger Lange
- Department of Cardiovascular Surgery, German Heart Center Munich, Munich, Bavaria, Germany
| |
Collapse
|
6
|
El-Sayed Ahmad A, Giammarino S, Salamate S, Fehske W, Sirat S, Amer M, Bramlage P, Bakhtiary F, Doss M. Clinical performance of a novel bioprosthetic surgical aortic valve in a German high-volume center. J Card Surg 2022; 37:4833-4840. [PMID: 36403275 DOI: 10.1111/jocs.17198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 09/23/2022] [Accepted: 10/26/2022] [Indexed: 11/21/2022]
Abstract
BACKGROUND AND AIM Bioprosthetic surgical aortic valve replacement (SAVR) is increasingly adopted in younger patients. We aimed to analyze mid-term follow-up data after SAVR to assess the performance of the prosthesis. METHODS Data were collected from a single-center series of 154 patients, who underwent SAVR with a bioprosthetic heart valve with the RESILIA tissue at our Heart Centre in Siegburg. All procedural and midterm patient outcomes were documented. RESULTS Patients had a mean age of 56.8 ± 9.9 years, 35.7% were female, and the mean logistic European system for cardiac operative risk evaluation (EuroSCORE) was 3.4 ± 3.6%. Diabetes (12.3%), atrial fibrillation (10.4%), and chronic obstructive pulmonary disease (COPD) (5.8%) were common comorbidities. The mean surgery duration was 163.8 ± 73.4 min, with the 23 mm (34.4%) and 25 mm (33.8%) heart valves being most frequently implanted. At 3-year follow-up, mean pressure gradient was 13.9 ± 5.9 mmHg, peak gradient was 23.6 ± 7.7 mmHg, and effective orifice area (EOA) was 1.9 ± 0.4 cm². No patient died during the operation, 3 (2.1%) patients within 30 days, and 4 (2.7%) thereafter with an overall mortality of n = 7. Of the surviving patients, 97.8% were in New York Heart Association (NYHA) class I/II and none had structural valve deterioration (SVD). CONCLUSION Results of our single-center study indicate favorable procedural outcomes. The safety outcomes confirm preliminary earlier results of this novel bioprosthesis but include more patients and a longer midterm follow-up.
Collapse
Affiliation(s)
- Ali El-Sayed Ahmad
- Division of Cardiac Surgery, Heart Centre Siegburg-Wuppertal, University Witten-Herdecke, Witten, Germany
| | - Sabrina Giammarino
- Division of Cardiac Surgery, Heart Centre Siegburg-Wuppertal, University Witten-Herdecke, Witten, Germany
| | - Saad Salamate
- Division of Cardiac Surgery, Heart Centre Siegburg-Wuppertal, University Witten-Herdecke, Witten, Germany.,Department of Cardiac Surgery, University Hospital Bonn, Bonn, Germany
| | - Wolfgang Fehske
- Division of Cardiac Surgery, Heart Centre Siegburg-Wuppertal, University Witten-Herdecke, Witten, Germany
| | - Sami Sirat
- Division of Cardiac Surgery, Heart Centre Siegburg-Wuppertal, University Witten-Herdecke, Witten, Germany
| | - Mohamed Amer
- Division of Cardiac Surgery, Heart Centre Siegburg-Wuppertal, University Witten-Herdecke, Witten, Germany
| | - Peter Bramlage
- Institute for Pharmacology and Preventive Medicine, Cloppenburg, Germany
| | - Farhad Bakhtiary
- Division of Cardiac Surgery, Heart Centre Siegburg-Wuppertal, University Witten-Herdecke, Witten, Germany.,Department of Cardiac Surgery, University Hospital Bonn, Bonn, Germany
| | - Mirko Doss
- Division of Cardiac Surgery, Heart Centre Siegburg-Wuppertal, University Witten-Herdecke, Witten, Germany
| |
Collapse
|
7
|
OUP accepted manuscript. Eur J Cardiothorac Surg. [DOI: 10.1093/ejcts/ezac030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Accepted: 12/23/2021] [Indexed: 11/13/2022] Open
|