• Reference Citation Analysis
  • v
  • v
  • Find an Article
  • Find an Author
Download
For: Kamboj S, Kahn B. Evaluation of Monte Carlo simulation of photon counting efficiency for germanium detectors. Health Phys 1996;70:512-519. [PMID: 8617591 DOI: 10.1097/00004032-199604000-00008] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Number Cited by Other Article(s)
1
Alharshan GA. Photopeak Efficiency and Coincidence Summing Factors for HPGe Detectors Using Bulk Sources. Health Phys 2020;118:396-401. [PMID: 31855594 DOI: 10.1097/hp.0000000000001143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
2
Shypailo RJ, Ellis KJ. Whole body counter calibration using Monte Carlo modeling with an array of phantom sizes based on national anthropometric reference data. Phys Med Biol 2011;56:2979-97. [DOI: 10.1088/0031-9155/56/10/006] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
3
Dewey SC, Whetstone ZD, Kearfott KJ. A numerical method for the calibration of in situ gamma ray spectroscopy systems. Health Phys 2010;98:657-671. [PMID: 20386196 DOI: 10.1097/hp.0b013e3181ca8ba8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
4
Kearfott KJ, Dewey SC. A method for the quantitative gamma spectroscopic analysis of an unusually shaped unknown source. Health Phys 2009;96:S31-S36. [PMID: 19125054 DOI: 10.1097/01.hp.0000336989.95911.1d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
5
Abbas MI, Nafee S, Selim YS. A simple mathematical method to determine the efficiencies of log-conical detectors. Radiat Phys Chem Oxf Engl 1993 2006. [DOI: 10.1016/j.radphyschem.2005.12.034] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
6
Kamboj S, Kahn B. Use of Monte Carlo simulation to examine gamma-ray interactions in germanium detectors. RADIAT MEAS 2003;37:1-8. [DOI: 10.1016/s1350-4487(02)00133-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
7
Lépy MC, Altzitzoglou T, Arnold D, Bronson F, Capote Noye R, Décombaz M, De Corte F, Edelmaier R, Herrera Peraza E, Klemola S, Korun M, Kralik M, Neder H, Plagnard J, Pommé S, De Sanoit J, Sima O, Ugletveit F, Van Velzen L, Vidmar T. Intercomparison of efficiency transfer software for gamma-ray spectrometry. Appl Radiat Isot 2001;55:493-503. [PMID: 11545502 DOI: 10.1016/s0969-8043(01)00101-4] [Citation(s) in RCA: 87] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
8
Abbas MI. HPGe detector photopeak efficiency calculation including self-absorption and coincidence corrections for Marinelli beaker sources using compact analytical expressions. Appl Radiat Isot 2001;54:761-8. [PMID: 11258525 DOI: 10.1016/s0969-8043(00)00308-0] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
9
Laborie JM, Le Petit G, Abt D, Girard M. Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level gamma-ray spectrometry using well-type HPGe detectors. Appl Radiat Isot 2000;53:57-62. [PMID: 10879838 DOI: 10.1016/s0969-8043(00)00114-7] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
10
Arnold D, Sima O. Coincidence-summing in gamma-ray spectrometry by excitation of matrix X-rays. Appl Radiat Isot 2000;52:725-32. [PMID: 10724432 DOI: 10.1016/s0969-8043(99)00236-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA