1
|
Decrease of 7T MR short-term effects with repeated exposure. Neuroradiology 2024; 66:567-575. [PMID: 38270624 PMCID: PMC10937769 DOI: 10.1007/s00234-024-03292-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 01/10/2024] [Indexed: 01/26/2024]
Abstract
PURPOSE Although participants in 7 T magnetic resonance (MR) studies tolerate ultra-high field (UHF) well, subjectively experienced short-term effects, such as dizziness, inconsistent movement, nausea, or metallic taste, are reported. Evidence on subjectively experienced short-term effects in multiple exposures to UHF MR is scarce. The purpose of this study is to investigated experience of short-term effects, and occurrence of motion in healthy subjects exposed to seven weekly 7 T MR examinations. METHODS A questionnaire on short-term effects was completed by participants in an fMRI motor skill study. Seven UHF MR examinations were conducted over 7 weeks (exposure number: 1 to 7). Changes of experienced short-term effects were analyzed. Motion in fMRI images was quantified. RESULTS The questionnaire was completed 360 times by 67 participants after one to seven 7T MR examinations. Logistic mixed model analysis showed a significant association between dizziness, inconsistent movement, nausea, and headache and the examination numbers (p<0.03). Exposure to repeated examinations had no significant effect on peripheral nerve stimulation (PNS) or motion of the subjects. The overall experience of a 7T examination improved significantly (p<0.001) with increasing examination numbers. CONCLUSION During multiple 7T examinations, subjects adapt to the strong static field. The short-term effects dizziness, inconsistent movement, nausea, and headache decrease over time as the MR sessions continue and experienced comfort increases. There was no significant difference in motion during the multiple fMRI examinations.
Collapse
|
2
|
Texture Analysis of Temporomandibular Joint Disc Changes Associated with Effusion Using Magnetic Resonance Images. Dent J (Basel) 2024; 12:82. [PMID: 38534306 DOI: 10.3390/dj12030082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 02/27/2024] [Accepted: 03/19/2024] [Indexed: 03/28/2024] Open
Abstract
The purpose of this study was to identify changes in the temporomandibular joint disc affected by effusion by using texture analysis of magnetic resonance images (MRIs). METHODS A total of 223 images of the TMJ, 42 with joint effusion and 181 without, were analyzed. Three consecutive slices were then exported to MaZda software, in which two oval ROIs (one in the anterior band and another in the intermediate zone of the joint disc) were determined in each slice and eleven texture parameters were calculated by using a gray-level co-occurrence matrix. Spearman's correlation coefficient test was used to assess the correlation between texture variables and to select variables for analysis. The Mann-Whitney test was used to compare the groups. RESULTS The significance level was set at 5%, with the results demonstrating that there was no high correlation between the parameter directions. It was possible to observe a trend between the average parameters, in which the group with effusion always had smaller values than the group without effusion, except for the parameter measuring the difference in entropy. CONCLUSION The trend towards lower overall values for the texture parameters suggested a different behavior between TMJ discs affected by effusion and those not affected, indicating that there may be intrinsic changes.
Collapse
|
3
|
First implementation of dynamic oxygen-17 ( 17O) magnetic resonance imaging at 7 Tesla during neuronal stimulation in the human brain. MAGMA (NEW YORK, N.Y.) 2024; 37:27-38. [PMID: 37737942 PMCID: PMC10876824 DOI: 10.1007/s10334-023-01119-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 08/27/2023] [Accepted: 08/31/2023] [Indexed: 09/23/2023]
Abstract
OBJECTIVE First implementation of dynamic oxygen-17 (17O) MRI at 7 Tesla (T) during neuronal stimulation in the human brain. METHODS Five healthy volunteers underwent a three-phase 17O gas (17O2) inhalation experiment. Combined right-side visual stimulus and right-hand finger tapping were used to achieve neuronal stimulation in the left cerebral hemisphere. Data analysis included the evaluation of the relative partial volume (PV)-corrected time evolution of absolute 17O water (H217O) concentration and of the relative signal evolution without PV correction. Statistical analysis was performed using a one-tailed paired t test. Blood oxygen level-dependent (BOLD) experiments were performed to validate the stimulation paradigm. RESULTS The BOLD maps showed significant activity in the stimulated left visual and sensorimotor cortex compared to the non-stimulated right side. PV correction of 17O MR data resulted in high signal fluctuations with a noise level of 10% due to small regions of interest (ROI), impeding further quantitative analysis. Statistical evaluation of the relative H217O signal with PV correction (p = 0.168) and without (p = 0.382) did not show significant difference between the stimulated left and non-stimulated right sensorimotor ROI. DISCUSSION The change of cerebral oxygen metabolism induced by sensorimotor and visual stimulation is not large enough to be reliably detected with the current setup and methodology of dynamic 17O MRI at 7 T.
Collapse
|
4
|
MRI Coil Development Strategies for Hybrid MR-PET Systems: A Review. IEEE Rev Biomed Eng 2024; 17:342-350. [PMID: 37015609 DOI: 10.1109/rbme.2022.3227337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Simultaneously operating MR-PET systems have the potential to provide synergetic multi-parametric information, and, as such, interest surrounding their use and development is increasing. However, despite the potential advantages offered by fully combined MR-PET systems, implementing this hybrid integration is technically laborious, and any factors degrading the quality of either modality must be circumvented to ensure optimal performance. In order to attain the best possible quality from both systems, most full MR-PET integrations tend to place the shielded PET system inside the MRI system, close to the target volume of the subject. The radiofrequency (RF) coil used in MRI systems is a key factor in determining the quality of the MR images, and, in simultaneous acquisition, it is generally positioned inside the PET system and PET imaging region, potentially resulting in attenuation and artefacts in the PET images. Therefore, when designing hybrid MR-PET systems, it is imperative that consideration be given to the RF coils inside the PET system. In this review, we present current state-of-the-art RF coil designs used for hybrid MR-PET experiments and discuss various design strategies for constructing PET transparent RF coils.
Collapse
|
5
|
7 T Lesion-Attenuated Magnetization-Prepared Gradient Echo Acquisition for Detection of Posterior Fossa Demyelinating Lesions in Multiple Sclerosis. Invest Radiol 2024:00004424-990000000-00187. [PMID: 38193790 DOI: 10.1097/rli.0000000000001050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2024]
Abstract
OBJECTIVES Detection of infratentorial demyelinating lesions in multiple sclerosis (MS) presents a challenge in magnetic resonance imaging (MRI), a difficulty that is further heightened in 7 T MRI. This study aimed to assess the efficacy of a novel MRI approach, lesion-attenuated magnetization-prepared gradient echo acquisition (LAMA), for detecting demyelinating lesions within the posterior fossa and upper cervical spine on 7 T MRI and contrast its performance with conventional double-inversion recovery (DIR) and T2-weighted turbo spin echo sequences. MATERIALS AND METHODS We conducted a retrospective cross-sectional study in 42 patients with a confirmed diagnosis of MS. All patients had 7 T MRI that incorporated LAMA, 3D DIR, and 2D T2-weighted turbo spin echo sequences. Three readers assessed lesion count in the brainstem, cerebellum, and upper cervical spinal cord using both DIR and T2-weighted images in one session. In a separate session, LAMA was analyzed alone. Contrast-to-noise ratio was also compared between LAMA and the conventional sequences. Lesion counts between methods were assessed using nonparametric Wilcoxon signed rank test. Interrater agreement in lesion detection was estimated by intraclass correlation coefficients. RESULTS LAMA identified a significantly greater number of lesions than DIR + T2 (mean 6.4 vs 3.0; P < 0.001). LAMA also exhibited better interrater agreement (intraclass correlation coefficient [95% confidence interval], 0.75 [0.41-0.88] vs 0.61 [0.35-0.78]). The contrast-to-noise ratio for LAMA (3.7 ± 0.9) significantly exceeded that of DIR (1.94 ± 0.7) and T2 (1.2 ± 0.7) (all P's < 0.001). In cases with no lesions detected using DIR + T2, at least 1 lesion was identified in 83.3% with LAMA. Across all analyzed brain regions, LAMA consistently detected more lesions than DIR + T2. CONCLUSIONS LAMA significantly improves the detection of infratentorial demyelinating lesions in MS patients compared with traditional methods. Integrating LAMA with standard magnetization-prepared 2 rapid acquisition gradient echo acquisition provides a valuable tool for accurately characterizing the extent of MS disease.
Collapse
|
6
|
Whole-Brain Intracellular pH Mapping of Gliomas Using High-Resolution 31P MR Spectroscopic Imaging at 7.0 T. Radiol Imaging Cancer 2024; 6:e220127. [PMID: 38133553 PMCID: PMC10825708 DOI: 10.1148/rycan.220127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 10/24/2023] [Accepted: 11/02/2023] [Indexed: 12/23/2023]
Abstract
Malignant tumors commonly exhibit a reversed pH gradient compared with normal tissue, with a more acidic extracellular pH and an alkaline intracellular pH (pHi). In this prospective study, pHi values in gliomas were quantified using high-resolution phosphorous 31 (31P) spectroscopic MRI at 7.0 T and were used to correlate pHi alterations with histopathologic findings. A total of 12 participants (mean age, 58 years ± 18 [SD]; seven male, five female) with histopathologically proven, newly diagnosed glioma were included between September 2018 and November 2019. The 31P spectroscopic MRI scans were acquired using a double-resonant 31P/1H phased-array head coil together with a three-dimensional (3D) 31P chemical shift imaging sequence (5.7-mL voxel volume) performed with a 7.0-T whole-body system. The 3D volumetric segmentations were performed for the whole-tumor volumes (WTVs); tumor subcompartments of necrosis, gadolinium enhancement, and nonenhancing T2 (NCE T2) hyperintensity; and normal-appearing white matter (NAWM), and pHi values were compared. Spearman correlation was used to assess association between pHi and the proliferation index Ki-67. For all study participants, mean pHi values were higher in the WTV (7.057 ± 0.024) compared with NAWM (7.006 ± 0.012; P < .001). In eight participants with high-grade gliomas, pHi was increased in all tumor subcompartments (necrosis, 7.075 ± 0.033; gadolinium enhancement, 7.075 ± 0.024; NCE T2 hyperintensity, 7.043 ± 0.015) compared with NAWM (7.004 ± 0.014; all P < .01). The pHi values of WTV positively correlated with Ki-67 (R2 = 0.74, r = 0.78, P = .001). In conclusion, 31P spectroscopic MRI at 7.0 T enabled high-resolution quantification of pHi in gliomas, with pHi alteration associated with the Ki-67 proliferation index, and may aid in diagnosis and treatment monitoring. Keywords: 31P MRSI, pH, Glioma, Glioblastoma, Ultra-High-Field MRI, Imaging Biomarker, 7 Tesla Supplemental material is available for this article. © RSNA, 2023.
Collapse
|
7
|
Recent technical developments and clinical research applications of sodium ( 23Na) MRI. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2023; 138-139:1-51. [PMID: 38065665 DOI: 10.1016/j.pnmrs.2023.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 04/11/2023] [Accepted: 04/13/2023] [Indexed: 12/18/2023]
Abstract
Sodium is an essential ion that plays a central role in many physiological processes including the transmembrane electrochemical gradient and the maintenance of the body's homeostasis. Due to the crucial role of sodium in the human body, the sodium nucleus is a promising candidate for non-invasively assessing (patho-)physiological changes. Almost 10 years ago, Madelin et al. provided a comprehensive review of methods and applications of sodium (23Na) MRI (Madelin et al., 2014) [1]. More recent review articles have focused mainly on specific applications of 23Na MRI. For example, several articles covered 23Na MRI applications for diseases such as osteoarthritis (Zbyn et al., 2016, Zaric et al., 2020) [2,3], multiple sclerosis (Petracca et al., 2016, Huhn et al., 2019) [4,5] and brain tumors (Schepkin, 2016) [6], or for imaging certain organs such as the kidneys (Zollner et al., 2016) [7], the brain (Shah et al., 2016, Thulborn et al., 2018) [8,9], and the heart (Bottomley, 2016) [10]. Other articles have reviewed technical developments such as radiofrequency (RF) coils for 23Na MRI (Wiggins et al., 2016, Bangerter et al., 2016) [11,12], pulse sequences (Konstandin et al., 2014) [13], image reconstruction methods (Chen et al., 2021) [14], and interleaved/simultaneous imaging techniques (Lopez Kolkovsky et al., 2022) [15]. In addition, 23Na MRI topics have been covered in review articles with broader topics such as multinuclear MRI or ultra-high-field MRI (Niesporek et al., 2019, Hu et al., 2019, Ladd et al., 2018) [16-18]. During the past decade, various research groups have continued working on technical improvements to sodium MRI and have investigated its potential to serve as a diagnostic and prognostic tool. Clinical research applications of 23Na MRI have covered a broad spectrum of diseases, mainly focusing on the brain, cartilage, and skeletal muscle (see Fig. 1). In this article, we aim to provide a comprehensive summary of methodological and hardware developments, as well as a review of various clinical research applications of sodium (23Na) MRI in the last decade (i.e., published from the beginning of 2013 to the end of 2022).
Collapse
|
8
|
Imaging in inflammatory arthritis: progress towards precision medicine. Nat Rev Rheumatol 2023; 19:650-665. [PMID: 37684361 DOI: 10.1038/s41584-023-01016-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/31/2023] [Indexed: 09/10/2023]
Abstract
Imaging techniques such as ultrasonography and MRI have gained ground in the diagnosis and management of inflammatory arthritis, as these imaging modalities allow a sensitive assessment of musculoskeletal inflammation and damage. However, these techniques cannot discriminate between disease subsets and are currently unable to deliver an accurate prediction of disease progression and therapeutic response in individual patients. This major shortcoming of today's technology hinders a targeted and personalized patient management approach. Technological advances in the areas of high-resolution imaging (for example, high-resolution peripheral quantitative computed tomography and ultra-high field MRI), functional and molecular-based imaging (such as chemical exchange saturation transfer MRI, positron emission tomography, fluorescence optical imaging, optoacoustic imaging and contrast-enhanced ultrasonography) and artificial intelligence-based data analysis could help to tackle these challenges. These new imaging approaches offer detailed anatomical delineation and an in vivo and non-invasive evaluation of the immunometabolic status of inflammatory reactions, thereby facilitating an in-depth characterization of inflammation. By means of these developments, the aim of earlier diagnosis, enhanced monitoring and, ultimately, a personalized treatment strategy looms closer.
Collapse
|
9
|
Quantification of regional CMRO 2 in human brain using dynamic 17O-MRI at 3T. Z Med Phys 2023:S0939-3889(23)00086-7. [PMID: 37558527 DOI: 10.1016/j.zemedi.2023.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 07/12/2023] [Accepted: 07/14/2023] [Indexed: 08/11/2023]
Abstract
OBJECTIVE To investigate the feasibility of cerebral metabolic rate of oxygen consumption (CMRO2) measurements with MRI at 3 Tesla in different brain regions. METHODS CMRO2 represents a key indicator of the physiological state of brain tissue. Dynamic 17O-MRI with inhalation of isotopically enriched 17O gas has been used to quantify global CMRO2 in brain white (WM) and gray matter (GM). However, global CMRO2 can only reflect the overall oxygen metabolism of the brain and cannot provide enough information on local tissue oxygen metabolism. To investigate the feasibility of determination of regional CMRO2 at a clinical 3 T MRI system, CMRO2 values in frontal, parietal and occipital WM and GM were determined in 5 healthy volunteers and compared to evaluate the regional differences of oxygen metabolism in WM and GM. Additionally, regional CMRO2 values were determined in deep brain structures including thalamus, dorsal striatum, caudate nucleus and insula cortex and in the cerebella, and compared with literature values from 15O-PET studies. RESULTS In cortical GM the determined CMRO2 values were in good agreement with the literature, whereas values in WM were about 32-48% higher than literature values. Regional analysis revealed a significantly higher CMRO2 in the occipital GM compared to the frontal and parietal GM. By contrast, no significant difference of CMRO2 was observed across the WM. In addition, CMRO2 in deep brain structures was lower compared to literature values and in the cerebella a good hemispheric symmetry of the tissue oxygen metabolism was found. CONCLUSION Dynamic 17O-MRI enables direct, non-invasive determination of regional CMRO2 in brain structures in healthy volunteers at 3T.
Collapse
|
10
|
Cardiothoracic and Vascular Surgery Implant Compatibility With Ultrahigh Field Magnetic Resonance Imaging (4.7 Tesla and 7 Tesla). Am J Cardiol 2023; 201:239-246. [PMID: 37392607 DOI: 10.1016/j.amjcard.2023.05.062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 05/23/2023] [Accepted: 05/31/2023] [Indexed: 07/03/2023]
Abstract
The use of 7 Tesla (T) magnetic resonance imaging (MRI) is expanding across medical specialties, particularly, clinical neurosciences and orthopedics. Investigational 7 T MRI has also been performed in cardiology. A limiting factor for expansion of the role of 7 T, irrespective of the body part being imaged, is the sparse testing of biomedical implant compatibility at field strengths >3 T. Implant compatibility can be tested following the American Society for Testing and Materials International guidelines. To assess the current state of cardiovascular implant safety at field strengths >3 T, a systematic search was performed using PubMed, Web of Science, and citation matching. Studies written in English that included at least 1 cardiovascular-related implant and at least 1 safety outcome (deflection angle, torque, or temperature change) were included. Data were extracted for the implant studied, implant composition, deflection angle, torque, and temperature change, and the American Society for Testing and Materials International standards were followed. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses reporting guidelines for scoping reviews were followed. A total of 9 studies were included. A total of 34 cardiovascular-related implants tested ex vivo at 7 T and 91 implants tested ex vivo at 4.7 T were included. The implants included vascular grafts and conduits, vascular access ports, peripheral and coronary stents, caval filters, and artificial valves. A total of 2 grafts, 1 vascular access port, 2 vena cava filters, and 5 stents were identified as incompatible with the 7 T MRI. All incompatible stents were 40 mm in length. Based on the safety outcomes reported, we identify several implants that may be compatible with >3 T MRI. This scoping review seeks to concisely summarize all the cardiovascular-related implants tested for ultrahigh field MRI compatibility to date.
Collapse
|
11
|
First application of dynamic oxygen-17 magnetic resonance imaging at 7 Tesla in a patient with early subacute stroke. Front Neurosci 2023; 17:1186558. [PMID: 37404469 PMCID: PMC10317041 DOI: 10.3389/fnins.2023.1186558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Accepted: 05/26/2023] [Indexed: 07/06/2023] Open
Abstract
Dynamic oxygen-17 (17O) magnetic resonance imaging (MRI) is an imaging method that enables a direct and non-invasive assessment of cerebral oxygen metabolism and thus potentially the distinction between viable and non-viable tissue employing a three-phase inhalation experiment. The purpose of this investigation was the first application of dynamic 17O MRI at 7 Tesla (T) in a patient with stroke. In this proof-of-concept experiment, dynamic 17O MRI was applied during 17O inhalation in a patient with early subacute stroke. The analysis of the relative 17O water (H217O) signal for the affected stroke region compared to the healthy contralateral side revealed no significant difference. However, the technical feasibility of 17O MRI has been demonstrated paving the way for future investigations in neurovascular diseases.
Collapse
|
12
|
Abstract
Sodium ions are essential for the functions of biological cells, and they are maintained at the balance between intra- and extracellular environments. The quantitative assessment of intra- and extracellular sodium as well as its dynamics can provide crucial physiological information on a living system. 23Na nuclear magnetic resonance (NMR) is a powerful and noninvasive technique to probe the local environment and dynamics of sodium ions. However, due to the complex relaxation behavior of the quadrupolar nucleus in the intermediate-motion regime and because of the heterogeneous compartments and diverse molecular interactions in the cellular environment, the understanding of the 23Na NMR signal in biological systems is still at the early stage. In this work, we characterize the relaxation and diffusion of sodium ions in the solutions of proteins and polysaccharides, as well as in the in vitro samples of living cells. The multi-exponential behavior of 23Na transverse relaxation has been analyzed according to the relaxation theory to derive the crucial information related to the ionic dynamics and molecular binding in the solutions. The bi-compartment model of transverse relaxation and diffusion measurements can corroborate each other to quantify the fractions of intra- and extracellular sodium. We show that 23Na relaxation and diffusion can be used to monitor the viability of human cells, which offers versatile NMR metrics for in vivo studies.
Collapse
|
13
|
Scaling the mountains: what lies above 7 Tesla magnetic resonance? MAGMA (NEW YORK, N.Y.) 2023; 36:151-157. [PMID: 37072540 PMCID: PMC10140119 DOI: 10.1007/s10334-023-01087-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 03/27/2023] [Indexed: 04/20/2023]
|
14
|
Germany's journey toward 14 Tesla human magnetic resonance. MAGMA (NEW YORK, N.Y.) 2023; 36:191-210. [PMID: 37029886 PMCID: PMC10140098 DOI: 10.1007/s10334-023-01085-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 03/23/2023] [Accepted: 03/27/2023] [Indexed: 04/09/2023]
Abstract
Multiple sites within Germany operate human MRI systems with magnetic fields either at 7 Tesla or 9.4 Tesla. In 2013, these sites formed a network to facilitate and harmonize the research being conducted at the different sites and make this technology available to a larger community of researchers and clinicians not only within Germany, but also worldwide. The German Ultrahigh Field Imaging (GUFI) network has defined a strategic goal to establish a 14 Tesla whole-body human MRI system as a national research resource in Germany as the next progression in magnetic field strength. This paper summarizes the history of this initiative, the current status, the motivation for pursuing MR imaging and spectroscopy at such a high magnetic field strength, and the technical and funding challenges involved. It focuses on the scientific and science policy process from the perspective in Germany, and is not intended to be a comprehensive systematic review of the benefits and technical challenges of higher field strengths.
Collapse
|
15
|
Radiofrequency antenna concepts for human cardiac MR at 14.0 T. MAGMA (NEW YORK, N.Y.) 2023; 36:257-277. [PMID: 36920549 PMCID: PMC10140016 DOI: 10.1007/s10334-023-01075-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 02/23/2023] [Accepted: 02/27/2023] [Indexed: 04/28/2023]
Abstract
OBJECTIVE To examine the feasibility of human cardiac MR (CMR) at 14.0 T using high-density radiofrequency (RF) dipole transceiver arrays in conjunction with static and dynamic parallel transmission (pTx). MATERIALS AND METHODS RF arrays comprised of self-grounded bow-tie (SGBT) antennas, bow-tie (BT) antennas, or fractionated dipole (FD) antennas were used in this simulation study. Static and dynamic pTx were applied to enhance transmission field (B1+) uniformity and efficiency in the heart of the human voxel model. B1+ distribution and maximum specific absorption rate averaged over 10 g tissue (SAR10g) were examined at 7.0 T and 14.0 T. RESULTS At 14.0 T static pTx revealed a minimum B1+ROI efficiency of 0.91 μT/√kW (SGBT), 0.73 μT/√kW (BT), and 0.56 μT/√kW (FD) and maximum SAR10g of 4.24 W/kg, 1.45 W/kg, and 2.04 W/kg. Dynamic pTx with 8 kT points indicate a balance between B1+ROI homogeneity (coefficient of variation < 14%) and efficiency (minimum B1+ROI > 1.11 µT/√kW) at 14.0 T with a maximum SAR10g < 5.25 W/kg. DISCUSSION MRI of the human heart at 14.0 T is feasible from an electrodynamic and theoretical standpoint, provided that multi-channel high-density antennas are arranged accordingly. These findings provide a technical foundation for further explorations into CMR at 14.0 T.
Collapse
|
16
|
MRI of Potassium and Sodium Enables Comprehensive Analysis of Ion Perturbations in Skeletal Muscle Tissue After Eccentric Exercise. Invest Radiol 2023; 58:265-272. [PMID: 36374200 PMCID: PMC9997635 DOI: 10.1097/rli.0000000000000931] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 08/22/2022] [Indexed: 11/16/2022]
Abstract
OBJECTIVES The aims were to investigate if potassium ( 39 K) magnetic resonance imaging (MRI) can be used to analyze changes in the apparent tissue potassium concentration (aTPC) in calf muscle tissue after eccentric exercise and in delayed-onset muscle soreness, and to compare these to corresponding changes in the apparent tissue sodium concentration (aTSC) measured with sodium ( 23 Na) MRI. MATERIALS AND METHODS Fourteen healthy subjects (7 female, 7 male; 25.0 ± 2.8 years) underwent 39 K and 23 Na MRI at a 7 T MR system, as well as 1 H MRI at a 3 T MR system. Magnetic resonance imaging data and blood samples were collected at baseline (t0), directly after performing eccentric exercise (t1) and 48 hours after exercise (t2). Self-reported muscle soreness was evaluated using a 10-cm visual analog scale for pain (0, no pain; 10, worst pain) at t0, t1, and t2. Quantification of aTPC/aTSC was performed after correcting the measured 39 K/ 23 Na signal intensities for partial volume and relaxation effects using 5 external reference phantoms. Edema volume and 1 H T 2 relaxation times were determined based on the 1 H MRI data. Participants were divided according to their increase in creatine kinase (CK) level into high (CK t2 ≥ 10·CK t0 ) and low CK (CK t2 < 10·CK t0 ) subjects. RESULTS Blood serum CK and edema volume were significantly increased 48 hours after exercise compared with baseline ( P < 0.001). Six participants showed a high increase in blood serum CK level at t2 relative to baseline, whereas 8 participants had only a low to moderate increase in blood serum CK. All participants reported increased muscle soreness both at rest and when climbing stairs at t1 (0.4 ± 0.7; 1.4 ± 1.2) and t2 (1.6 ± 1.4; 4.8 ± 1.9) compared with baseline (0 ± 0; 0 ± 0). Moreover, aTSC was increased at t1 in exercised muscles of all participants (increase by 57% ± 24% in high CK, 73% ± 33% in low CK subjects). Forty-eight hours after training, subjects with high increase in blood serum CK still showed highly increased aTSC (increase by 79% ± 57% compared with t0). In contrast, aTPC at t2 was elevated in exercised muscles of low CK subjects (increase by 19% ± 11% compared with t0), in which aTSC had returned to baseline or below. Overall, aTSC and aTPC showed inverse evolution, with changes in aTSC being approximately twice as high as in aTPC. CONCLUSIONS Our results showed that 39 K MRI is able to detect changes in muscular potassium concentrations caused by eccentric exercise. In combination with 23 Na MRI, this enables a more holistic analysis of tissue ion concentration changes.
Collapse
|
17
|
Neurosurgical Implant Safety in 7 T MRI: A Scoping Review. J Magn Reson Imaging 2023; 57:661-669. [PMID: 36173367 DOI: 10.1002/jmri.28449] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 09/13/2022] [Accepted: 09/15/2022] [Indexed: 11/11/2022] Open
Abstract
The use of 7 Tesla (T) magnetic resonance imaging (MRI) is expanding across neurosurgical and neurologic specialties. However, few neurosurgical-related implants have been tested for safety at 7 T, limiting its use in patients with cranial fixation, shunt placements, and other implants. Implant safety can be determined via the American Society for Testing Materials International (ASTM) guidelines. To assess the current state of neurosurgical implant safety at 7 T, a systematic search was performed using PubMed, MEDLINE, Web of Knowledge, and citation matching. Studies written in English that included at least one neurosurgical implant and at least one safety outcome were included. Data were extracted for implant studied, implant composition, deflection angle, torque, temperature change, and ASTM guidelines followed. PRISMA reporting guidelines for scoping reviews were followed. Overall, 18 studies consisting of 45 unique implants were included. Implants included cranial fixation devices, aneurysm clips, spinal rods, pedicle screws, ventriculoperitoneal (VP) shunts, deep brain stimulation devices, and electroencephalogram (EEG) caps and electrodes. Cranial fixation devices, deep brain stimulation devices, spinal rods, and pedicle screws are likely 7 T MRI compatible based on outcomes reported. Aneurysm clips and EEG devices had variable safety outcomes. The VP shunts studied lost functionality after 7 T MRI exposure. We identified several implants that are likely compatible with 7 T MRI. Given the growth in 7 T imaging and expansion of the technology, neurosurgical implants should be constructed with the aforementioned considerations. Caution must be taken with all implants, especially aneurysm clips, programmable VP shunts, and EEG recording devices. It is also noteworthy that several implant testing reports did not report following ASTM standards. This scoping review seeks to concisely summarize all neurosurgical-related implants that have been tested for safety in 7 T MRI. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.
Collapse
|
18
|
Clinical Application of Ultrahigh-Field-Strength Wrist MRI: A Multireader 3-T and 7-T Comparison Study. Radiology 2023; 307:e220753. [PMID: 36625744 DOI: 10.1148/radiol.220753] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Background Ultrahigh-field-strength MRI at 7 T may permit superior visualization of noninflammatory wrist pathologic conditions, particularly due to its high signal-to-noise ratio compared with the clinical standard of 3 T, but direct comparison studies are lacking. Purpose To compare the subjective image quality of 3-T and 7-T ultrahigh-field-strength wrist MRI through semiquantitative scoring of multiple joint tissues in a multireader study. Materials and Methods In this prospective study, healthy controls and participants with chronic wrist pain underwent 3-T and 7-T MRI (coronal T1-weighted turbo spin-echo [TSE], coronal fat-suppressed proton-density [PD]-weighted TSE, transversal T2-weighted TSE) on the same day, from July 2018 to June 2019. Images were scored by seven musculoskeletal radiologists. The overall image quality, presence of artifacts, homogeneity of fat suppression, and visualization of cartilage, the triangular fibrocartilage complex (TFCC), and scapholunate and lunotriquetral ligaments were semiquantitatively assessed. Pairwise differences between 3 T and 7 T were assessed using the Wilcoxon signed-rank test. Interreader reliability was determined using the Fleiss kappa. Results In total, 25 healthy controls (mean age, 25 years ± 4 [SD]; 13 women) and 25 participants with chronic wrist pain (mean age, 39 years ± 16; 14 men) were included. Overall image quality (P = .002) and less presence of artifacts at PD-weighted fat-suppressed MRI were superior at 7 T. T1- and T2-weighted MRI were superior at 3 T (both P < .001), as was fat suppression (P < .001). Visualization of cartilage was superior at 7 T (P < .001), while visualization of the TFCC (P < .001) and scapholunate (P = .048) and lunotriquetral (P = .04) ligaments was superior at 3 T. Interreader reliability showed slight to substantial agreement for the detected pathologic conditions (κ = 0.20-0.64). Conclusion A 7-T MRI of the wrist had potential advantages over 3-T MRI, particularly in cartilage assessment. However, superiority was not shown for all parameters; for example, visualization of the triangular fibrocartilage complex and wrist ligaments was superior at 3 T. © RSNA, 2023 Supplemental material is available for this article.
Collapse
|
19
|
Abstract
ABSTRACT This review summarizes the current state-of-the-art of musculoskeletal 7 T magnetic resonance imaging (MRI), the associated technological challenges, and gives an overview of current and future clinical applications of 1 H-based 7 T MRI. The higher signal-to-noise ratio at 7 T is predominantly used for increased spatial resolution and thus the visualization of anatomical details or subtle lesions rather than to accelerate the sequences. For musculoskeletal MRI, turbo spin echo pulse sequences are particularly useful, but with altered relaxation times, B1 inhomogeneity, and increased artifacts at 7 T; specific absorption rate limitation issues quickly arise for turbo spin echo pulse sequences. The development of dedicated pulse sequence techniques in the last 2 decades and the increasing availability of specialized coils now facilitate several clinical musculoskeletal applications. 7 T MRI is performed in vivo in a wide range of applications for the knee joint and other anatomical areas, such as ultra-high-resolution nerve imaging or bone trabecular microarchitecture imaging. So far, however, it has not been shown systematically whether the higher field strength compared with the established 3 T MRI systems translates into clinical advantages, such as an early-stage identification of tissue damage allowing for preventive therapy or an influence on treatment decisions and patient outcome. At the moment, results tend to suggest that 7 T MRI will be reserved for answering specific, targeted musculoskeletal questions rather than for a broad application, as is the case for 3 T MRI. Future data regarding the implementation of clinical use cases are expected to clarify if 7 T musculoskeletal MRI applications with higher diagnostic accuracy result in patient benefits compared with MRI at lower field strengths.
Collapse
|
20
|
The RPL/RPS gene signature of melanoma CTCs associates with brain metastasis. CANCER RESEARCH COMMUNICATIONS 2022; 2:1436-1448. [PMID: 36407834 PMCID: PMC9668078 DOI: 10.1158/2767-9764.crc-22-0337] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Melanoma brain metastasis (MBM) is linked to poor prognosis and low overall survival. We hypothesized that melanoma circulating tumor cells (CTCs) possess a gene signature significantly expressed and associated with MBM. Employing a multi-pronged approach, we provide first-time evidence identifying a common CTC gene signature for ribosomal protein large/small subunits (RPL/RPS) which associate with MBM onset and progression. Experimental strategies involved capturing, transcriptional profiling and interrogating CTCs, either directly isolated from blood of melanoma patients at distinct stages of MBM progression or from CTC-driven MBM in experimental animals. Second, we developed the first Magnetic Resonance Imaging (MRI) CTC-derived MBM xenograft model (MRI-MBM CDX) to discriminate MBM spatial and temporal growth, recreating MBM clinical presentation and progression. Third, we performed the comprehensive transcriptional profiling of MRI-MBM CDXs, along with longitudinal monitoring of CTCs from CDXs possessing/not possessing MBM. Our findings suggest that enhanced ribosomal protein content/ribogenesis may contribute to MBM onset. Since ribosome modifications drive tumor progression and metastatic development by remodeling CTC translational events, overexpression of the CTC RPL/RPS gene signature could be implicated in MBM development. Collectively, this study provides important insights for relevance of the CTC RPL/RPS gene signature in MBM, and identify potential targets for therapeutic intervention to improve patient care for melanoma patients diagnosed with or at high-risk of developing MBM.
Collapse
|
21
|
Assessing the influence of the menstrual cycle on APT CEST-MRI in the human breast. Magn Reson Imaging 2022; 91:24-31. [PMID: 35550841 DOI: 10.1016/j.mri.2022.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 05/05/2022] [Accepted: 05/05/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE In fibroglandular breast tissue, conventional dynamic contrast-enhanced MR-mammography is known to be affected by water content changes during the menstrual cycle. Likewise, amide proton transfer (APT) chemical exchange saturation transfer (CEST)-MRI might be inherently prone to the menstrual cycle, as CEST signals are indirectly detected via the water signal. The purpose of this study was to investigate the influence of the menstrual cycle on APT CEST-MRI in fibroglandular breast tissue. METHOD Ten healthy premenopausal women (19-34 years) were included in this IRB approved prospective study and examined twice during their menstrual cycle. Examination one and two were performed during the first half (day 2-8) and the second half (day 15-21) of the menstrual cycle, respectively. As a reference for the APT signal in malignant breast tumor tissue, previously reported data of nine breast cancer patients were included in this study. CEST-MRI (B1 = 0.7μT) was performed on a 7 T whole-body scanner followed by a multi-Lorentzian fit analysis. The APT signal was corrected for B0/B1-field inhomogeneities, fat signal contribution, and relaxation effects of the water signal and evaluated in the fibroglandular breast tissue. Intra-individual APT signal differences between examination one and two were compared using the Wilcoxon signed-rank test. The level of significance was set at p < 0.05. RESULTS The APT signal showed no significant difference in the fibroglandular breast tissue of healthy premenopausal volunteers throughout the menstrual cycle (p = 1.00) (examination 1 vs. examination 2: mean and standard deviation = 3.24 ± 0.68%Hz vs. 3.30 ± 0.73%Hz, median and IQR = 3.36%Hz and 0.87%Hz vs. 3.38%Hz and 0.71%Hz). CONCLUSION The present study provides an important basis for the clinical application of APT CEST-MRI as an additional contrast mechanism in MR-mammography, as menstrual cycle-related APT signal fluctuations seem to be negligible compared to the APT signal increase in breast cancer tissue.
Collapse
|
22
|
Ultra-High-Field MRI in the Diagnosis and Management of Gliomas: A Systematic Review. Front Neurol 2022; 13:857825. [PMID: 35449515 PMCID: PMC9016277 DOI: 10.3389/fneur.2022.857825] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Accepted: 03/02/2022] [Indexed: 12/03/2022] Open
Abstract
Importance: Gliomas, tumors of the central nervous system, are classically diagnosed through invasive surgical biopsy and subsequent histopathological study. Innovations in ultra-high field (UHF) imaging, namely 7-Tesla magnetic resonance imaging (7T MRI) are advancing preoperative tumor grading, visualization of intratumoral structures, and appreciation of small brain structures and lesions. Objective Summarize current innovative uses of UHF imaging techniques in glioma diagnostics and treatment. Methods A systematic review in accordance with PRISMA guidelines was performed utilizing PubMed. Case reports and series, observational clinical trials, and randomized clinical trials written in English were included. After removing unrelated studies and those with non-human subjects, only those related to 7T MRI were independently reviewed and summarized for data extraction. Some preclinical animal models are briefly described to demonstrate future usages of ultra-high-field imaging. Results We reviewed 46 studies (43 human and 3 animal models) which reported clinical usages of UHF MRI in the diagnosis and management of gliomas. Current literature generally supports greater resolution imaging from 7T compared to 1.5T or 3T MRI, improving visualization of cerebral microbleeds and white and gray matter, and providing more precise localization for radiotherapy targeting. Additionally, studies found that diffusion or susceptibility-weighted imaging techniques applied to 7T MRI, may be used to predict tumor grade, reveal intratumoral structures such as neovasculature and microstructures like axons, and indicate isocitrate dehydrogenase 1 mutation status in preoperative imaging. Similarly, newer imaging techniques such as magnetic resonance spectroscopy and chemical exchange saturation transfer imaging can be performed on 7T MRI to predict tumor grading and treatment efficacy. Geometrical distortion, a known challenge of 7T MRI, was at a tolerable level in all included studies. Conclusion UHF imaging has the potential to preoperatively and non-invasively grade gliomas, provide precise therapy target areas, and visualize lesions not seen on conventional MRI.
Collapse
|
23
|
Ultra-High-Field 7 T Magnetic Resonance Imaging Including Dynamic and Static Contrast-Enhanced T1-Weighted Imaging Improves Detection of Secreting Pituitary Microadenomas. Invest Radiol 2022; 57:567-574. [PMID: 35925660 DOI: 10.1097/rli.0000000000000872] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVE A prospective preoperative evaluation of 7 T ultra-high-field magnetic resonance imaging (MRI) in patients with suspected pituitary microadenomas for both adenoma detection and intrasellar localization compared with 3 T MRI was carried out. MATERIALS AND METHODS Patients underwent prospective preoperative standardized 3 and 7 T MRI. A distinct qualitative (lesion detection, intrasellar lesion location) and quantitative (lesion diameters, T1/T2 signal intensity ratio of the lesion to normal pituitary gland tissue) analysis was performed, along with an evaluation of image quality (IQ) regarding overall IQ, anatomical parameters, and artifacts; the findings of the qualitative analysis were compared with intraoperative findings and endocrinological outcomes. RESULTS Sixteen patients (mean age, 43 ± 16 years; 13 women) with pituitary microadenomas were included. Using 7 T MRI allowed the detection of 15 microadenomas-3 more than 3 T MRI. In addition, 7 T MRI allowed more precise lesion localization with 93.75% (15/16) agreement with intraoperative findings, compared with 75% (12/16) agreement using 3 T MRI. Lesion diameters showed no significant difference between 3 and 7 T MRI. T1 and T2 signal intensity ratio between microadenomas and normal pituitary gland tissue were higher in 7 T MRI than in 3 T MRI. The overall IQ and the IQ of each anatomical parameter of 7 T MRI were rated higher than those of 3 T MRI. No significant differences in susceptibility or head motion artifacts were observed between 3 and 7 T MRI; however, 7 T MRI was more susceptible to pulsation artifacts. CONCLUSION Ultra-high-field MRI surpasses 3 T MRI in pituitary microadenoma detection and enables more precise delineation with higher correlation with intraoperative findings. Thus, 7 T sellar imaging is a promising option-especially in previously magnetic resonance-negative patients with endocrinologically confirmed hormone oversecretion-and helps reduce the need for invasive diagnostics.
Collapse
|
24
|
A Preliminary Study for Reference RF Coil at 11.7 T MRI: Based on Electromagnetic Field Simulation of Hybrid-BC RF Coil According to Diameter and Length at 3.0, 7.0 and 11.7 T. SENSORS 2022; 22:s22041512. [PMID: 35214409 PMCID: PMC8875900 DOI: 10.3390/s22041512] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 02/13/2022] [Accepted: 02/14/2022] [Indexed: 02/05/2023]
Abstract
Magnetic resonance imaging (MRI) systems must undergo quantitative evaluation through daily and periodic performance assessments. In general, the reference or standard radiofrequency (RF) coils for these performance assessments of 1.5 to 7.0 T MRI systems have been low-pass-type birdcage (LP-BC) RF coils. However, LP-BC RF coils are inappropriate for use as reference RF coils because of their relatively lower magnetic field (B1-field) sensitivity than other types of BC RF coils, especially in ultrahigh-field (UHF) MRI systems above 3.0 T. Herein, we propose a hybrid-type BC (Hybrid-BC) RF coil as a reference RF coil with improved B1-field sensitivity in UHF MRI system and applied it to an 11.7 T MRI system. An electromagnetic field (EM-field) analysis on the Hybrid-BC RF coil was performed to provide the proper dimensions for its use as a reference RF coil. Commercial finite difference time-domain program was used in EM-field simulation, and home-made analysis programs were used in analysis. The optimal specifications of the proposed Hybrid-BC RF coils for them to qualify as reference RF coils are proposed based on their B1+-field sensitivity under unnormalized conditions, as well as by considering their B1+-field uniformity and RF safety under normalized conditions.
Collapse
|
25
|
Test-retest stability of spontaneous brain activity and functional connectivity in the core resting-state networks assessed with ultrahigh field 7-Tesla resting-state functional magnetic resonance imaging. Hum Brain Mapp 2022; 43:2026-2040. [PMID: 35044722 PMCID: PMC8933332 DOI: 10.1002/hbm.25771] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 11/26/2021] [Accepted: 12/14/2021] [Indexed: 12/12/2022] Open
Abstract
The growing demand for precise and reliable biomarkers in psychiatry is fueling research interest in the hope that identifying quantifiable indicators will improve diagnoses and treatment planning across a range of mental health conditions. The individual properties of brain networks at rest have been highlighted as a possible source for such biomarkers, with the added advantage that they are relatively straightforward to obtain. However, an important prerequisite for their consideration is their reproducibility. While the reliability of resting‐state (RS) measurements has often been studied at standard field strengths, they have rarely been investigated using ultrahigh‐field (UHF) magnetic resonance imaging (MRI) systems. We investigated the intersession stability of four functional MRI RS parameters—amplitude of low‐frequency fluctuations (ALFF) and fractional ALFF (fALFF; representing the spontaneous brain activity), regional homogeneity (ReHo; measure of local connectivity), and degree centrality (DC; measure of long‐range connectivity)—in three RS networks, previously shown to play an important role in several psychiatric diseases—the default mode network (DMN), the central executive network (CEN), and the salience network (SN). Our investigation at individual subject space revealed a strong stability for ALFF, ReHo, and DC in all three networks, and a moderate level of stability in fALFF. Furthermore, the internetwork connectivity between each network pair was strongly stable between CEN/SN and moderately stable between DMN/SN and DMN/SN. The high degree of reliability and reproducibility in capturing the properties of the three major RS networks by means of UHF‐MRI points to its applicability as a potentially useful tool in the search for disease‐relevant biomarkers.
Collapse
|
26
|
The Clinical Utility of Magnetic Resonance Imaging According to Field Strength, Specifically Addressing the Breadth of Current State-of-the-Art Systems, Which Include 0.55 T, 1.5 T, 3 T, and 7 T. Invest Radiol 2022; 57:1-12. [PMID: 34510100 DOI: 10.1097/rli.0000000000000824] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
ABSTRACT This review provides a balanced perspective regarding the clinical utility of magnetic resonance systems across the range of field strengths for which current state-of-the-art units exist (0.55 T, 1.5 T, 3 T, and 7 T). Guidance regarding this issue is critical to appropriate purchasing, usage, and further dissemination of this important imaging modality, both in the industrial world and in developing nations. The review serves to provide an important update, although to a large extent this information has never previously been openly presented. In that sense, it serves also as a position paper, with statements and recommendations as appropriate.
Collapse
|
27
|
Assessment of Sodium MRI at 7 Tesla as Predictor of Therapy Response and Survival in Glioblastoma Patients. Front Neurosci 2021; 15:782516. [PMID: 34924945 PMCID: PMC8671745 DOI: 10.3389/fnins.2021.782516] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 11/09/2021] [Indexed: 11/13/2022] Open
Abstract
The purpose of this work was to prospectively investigate sodium (23Na) MRI at 7 Tesla (T) as predictor of therapy response and survival in patients with glioblastoma (GBM). Thus, 20 GBM patients underwent 23Na MRI at 7T before, immediately after and 6 weeks after chemoradiotherapy (CRT). The median tissue sodium concentration (TSC) inside the whole tumor excluding necrosis was determined. Initial response to CRT was assessed employing the updated response assessment in neuro-oncology working group (RANO) criteria. Clinical parameters, baseline TSC and longitudinal TSC differences were compared between patients with initial progressive disease (PD) and patients with initial stable disease (SD) using Fisher’s exact tests and Mann-Whitney-U-tests. Univariate proportional hazard models for progression free survival (PFS) and overall survival (OS) were calculated using clinical parameters and TSC metrics as predictor variables. The analyses demonstrated that TSC developed heterogeneously over all patients following CRT. None of the TSC metrics differed significantly between cases of initial SD and initial PD. Furthermore, TSC metrics did not yield a significant association with PFS or OS. Conversely, the initial response according to the RANO criteria could significantly predict PFS [univariate HR (95%CI) = 0.02 (0.0001–0.21), p < 0.001] and OS [univariate HR = 0.17 (0.04–0.65), p = 0.005]. In conclusion, TSC showed treatment-related changes in GBM following CRT, but did not significantly correlate with the initial response according to the RANO criteria, PFS or OS. In contrast, the initial response according to the RANO criteria was a significant predictor of PFS and OS. Future investigations need to elucidate the reasons for treatment-related changes in TSC and their clinical value for response prediction in glioblastoma patients receiving CRT.
Collapse
|
28
|
Abstract
A stroke occurs when the blood flow to the brain is suddenly interrupted, depriving brain cells of oxygen and glucose and leading to further cell death. Neuroimaging techniques, such as computed tomography and magnetic resonance imaging, have greatly improved our ability to visualise brain structures and are routinely used to diagnose the affected vascular region of a stroke patient's brain and to inform decisions about clinical care. Currently, these multimodal imaging techniques are the backbone of the clinical management of stroke patients and have immensely improved our ability to visualise brain structures. Here, we review recent developments in the field of neuroimaging and discuss how different imaging techniques are used in the diagnosis, prognosis and treatment of stroke. Summary: Stroke imaging has undergone seismic shifts in the past decade. Although magnetic resonance imaging (MRI) is superior to computed tomography in providing vital information, further research on MRI is still required to bring its full potential into clinical practice.
Collapse
|