1
|
Pellow C, Jafari Sojahrood A, Zhao X, Kolios MC, Exner AA, Goertz DE. Synchronous Intravital Imaging and Cavitation Monitoring of Antivascular Focused Ultrasound in Tumor Microvasculature Using Monodisperse Low Boiling Point Nanodroplets. ACS Nano 2024; 18:410-427. [PMID: 38147452 PMCID: PMC10786165 DOI: 10.1021/acsnano.3c07711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 12/18/2023] [Accepted: 12/20/2023] [Indexed: 12/28/2023]
Abstract
Focused ultrasound-stimulated microbubbles can induce blood flow shutdown and ischemic necrosis at higher pressures in an approach termed antivascular ultrasound. Combined with conventional therapies of chemotherapy, immunotherapy, and radiation therapy, this approach has demonstrated tumor growth inhibition and profound synergistic antitumor effects. However, the lower cavitation threshold of microbubbles can potentially yield off-target damage that the polydispersity of clinical agent may further exacerbate. Here we investigate the use of a monodisperse nanodroplet formulation for achieving antivascular effects in tumors. We first develop stable low boiling point monodisperse lipid nanodroplets and examine them as an alternative agent to mediate antivascular ultrasound. With synchronous intravital imaging and ultrasound monitoring of focused ultrasound-stimulated nanodroplets in tumor microvasculature, we show that nanodroplets can trigger blood flow shutdown and do so with a sharper pressure threshold and with fewer additional events than conventionally used microbubbles. We further leverage the smaller size and prolonged pharmacokinetic profile of nanodroplets to allow for potential passive accumulation in tumor tissue prior to antivascular ultrasound, which may be a means by which to promote selective tumor targeting. We find that vascular shutdown is accompanied by inertial cavitation and complex-order sub- and ultraharmonic acoustic signatures, presenting an opportunity for effective feedback control of antivascular ultrasound.
Collapse
Affiliation(s)
- Carly Pellow
- Sunnybrook Research Institute, Toronto M4N 3M5, Canada
| | - Amin Jafari Sojahrood
- Sunnybrook Research Institute, Toronto M4N 3M5, Canada
- Department of Physics, Toronto Metropolitan University, Toronto M5B 2K3, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), a partnership between St. Michael's Hospital, a site of Unity Health Toronto and Toronto Metropolitan University, Toronto M5B 1T8, Canada
| | - Xiaoxiao Zhao
- Sunnybrook Research Institute, Toronto M4N 3M5, Canada
- Department of Medical Biophysics, University of Toronto, Toronto M5G 1L7, Canada
| | - Michael C Kolios
- Department of Physics, Toronto Metropolitan University, Toronto M5B 2K3, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), a partnership between St. Michael's Hospital, a site of Unity Health Toronto and Toronto Metropolitan University, Toronto M5B 1T8, Canada
| | - Agata A Exner
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio 44106, United States
| | - David E Goertz
- Sunnybrook Research Institute, Toronto M4N 3M5, Canada
- Department of Medical Biophysics, University of Toronto, Toronto M5G 1L7, Canada
| |
Collapse
|
2
|
Li T, Li S, Shi J, Li X, Liu J, Yang H, Wu W, Zhao L, Zhao Z. Real-time analysis of metabolites in vivo by online extraction electrospray ionization mass spectrometry coupled to microdialysis. Anal Chim Acta 2022; 1205:339760. [DOI: 10.1016/j.aca.2022.339760] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Revised: 03/16/2022] [Accepted: 03/22/2022] [Indexed: 01/10/2023]
|
3
|
Wang S, Hossack JA, Klibanov AL. From Anatomy to Functional and Molecular Biomarker Imaging and Therapy: Ultrasound Is Safe, Ultrafast, Portable, and Inexpensive. Invest Radiol 2020; 55:559-72. [PMID: 32776766 DOI: 10.1097/RLI.0000000000000675] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Ultrasound is the most widely used medical imaging modality worldwide. It is abundant, extremely safe, portable, and inexpensive. In this review, we consider some of the current development trends for ultrasound imaging, which build upon its current strength and the popularity it experiences among medical imaging professional users.Ultrasound has rapidly expanded beyond traditional radiology departments and cardiology practices. Computing power and data processing capabilities of commonly available electronics put ultrasound systems in a lab coat pocket or on a user's mobile phone. Taking advantage of new contributions and discoveries in ultrasound physics, signal processing algorithms, and electronics, the performance of ultrasound systems and transducers have progressed in terms of them becoming smaller, with higher imaging performance, and having lower cost. Ultrasound operates in real time, now at ultrafast speeds; kilohertz frame rates are already achieved by many systems.Ultrasound has progressed beyond anatomical imaging and monitoring blood flow in large vessels. With clinical approval of ultrasound contrast agents (gas-filled microbubbles) that are administered in the bloodstream, tissue perfusion studies are now routine. Through the use of modern ultrasound pulse sequences, individual microbubbles, with subpicogram mass, can be detected and observed in real time, many centimeters deep in the body. Ultrasound imaging has broken the wavelength barrier; by tracking positions of microbubbles within the vasculature, superresolution imaging has been made possible. Ultrasound can now trace the smallest vessels and capillaries, and obtain blood velocity data in those vessels.Molecular ultrasound imaging has now moved closer to clinic; the use of microbubbles with a specific affinity to endothelial biomarkers allows selective accumulation and retention of ultrasound contrast in the areas of ischemic injury, inflammation, or neoangiogenesis. This will aid in noninvasive molecular imaging and may provide additional help with real-time guidance of biopsy, surgery, and ablation procedures.The ultrasound field can be tightly focused inside the body, many centimeters deep, with millimeter precision, and ablate lesions by energy deposition, with thermal or mechanical bioeffects. Some of such treatments are already in clinical use, with more indications progressing through the clinical trial stage. In conjunction with intravascular microbubbles, focused ultrasound can be used for tissue-specific drug delivery; localized triggered release of sequestered drugs from particles in the bloodstream may take time to get to clinic. A combination of intravascular microbubbles with circulating drug and low-power ultrasound allows transient opening of vascular endothelial barriers, including blood-brain barrier; this approach has reached clinical trial stage. Therefore, the drugs that normally would not be getting to the target tissue in the brain will now have an opportunity to produce therapeutic efficacy.Overall, medical ultrasound is developing at a brisk rate, even in an environment where other imaging modalities are also advancing rapidly and may be considered more lucrative. With all the current advances that we discuss, and many more to come, ultrasound may help solve many problems that modern medicine is facing.
Collapse
|
4
|
Helfield BL, Yoo K, Liu J, Williams R, Sheeran PS, Goertz DE, Burns PN. Investigating the Accumulation of Submicron Phase-Change Droplets in Tumors. Ultrasound Med Biol 2020; 46:2861-2870. [PMID: 32732167 DOI: 10.1016/j.ultrasmedbio.2020.06.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 06/24/2020] [Accepted: 06/27/2020] [Indexed: 06/11/2023]
Abstract
Submicron phase-change droplets are an emerging class of ultrasound contrast agent. Compared with microbubbles, their relatively small size and increased stability offer the potential to passively extravasate and accumulate in solid tumors through the enhanced permeability and retention effect. Under exposure to sufficiently powerful ultrasound, these droplets can convert into in situ gas microbubbles and thus be used as an extravascular-specific contrast agent. However, in vivo imaging methods to detect extravasated droplets have yet to be established. Here, we develop an ultrasound imaging pulse sequence within diagnostic safety limits to selectively detect droplet extravasation in tumors. Tumor-bearing mice were injected with submicron perfluorobutane droplets and interrogated with our imaging-vaporization-imaging sequence. By use of a pulse subtraction method, median droplet extravasation signal relative to the total signal within the tumor was estimated to be Etumor=37±5% compared with the kidney Ekidney=-2±8% (p < 0.001). This work contributes toward the advancement of volatile phase-shift droplets as a next-generation ultrasound agent for imaging and therapy.
Collapse
Affiliation(s)
- Brandon L Helfield
- Department of Physics, Concordia University, Montreal, Canada; Department of Biology, Concordia University, Montreal, Canada.
| | - Kimoon Yoo
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Jingjing Liu
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Ross Williams
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
| | - Paul S Sheeran
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - David E Goertz
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Peter N Burns
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada
| |
Collapse
|
5
|
Aliabouzar M, Lu X, Kripfgans OD, Fowlkes JB, Fabiilli ML. Acoustic Droplet Vaporization in Acoustically Responsive Scaffolds: Effects of Frequency of Excitation, Volume Fraction and Threshold Determination Method. Ultrasound Med Biol 2019; 45:3246-3260. [PMID: 31561948 PMCID: PMC6823163 DOI: 10.1016/j.ultrasmedbio.2019.08.018] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Revised: 08/11/2019] [Accepted: 08/23/2019] [Indexed: 05/03/2023]
Abstract
Ultrasound-induced vaporization of liquid perfluorocarbon (PFC) droplets into microbubbles, termed acoustic droplet vaporization (ADV), has potential therapeutic and diagnostic applications. Recently, we demonstrated how ADV-a threshold-based phenomenon-can modulate the release of biomolecules from composite hydrogels, thereby stimulating regenerative processes, such as angiogenesis. These composite hydrogels, called acoustically responsive scaffolds (ARSs), consist of monodispersed, micron size PFC emulsions embedded within a fibrin matrix. This study investigated the effects of frequency of excitation (2.25, 5, 7.5 and 10 MHz) and volume fraction (0.05%, 0.2% and 1% [v/v]) of monodispersed, double emulsions in the ARSs on the ADV threshold. We determined and compared the ADV thresholds via acoustic methods, including active detection, passive detection and attenuation, as well as an echogenicity-based method using B-mode imaging. The ADV threshold determined via these four techniques showed an increasing trend with frequency of excitation. Further analysis of the wave propagation showed that the amplitudes of high frequency harmonics were diminished in ARSs with high volume fractions of emulsion. The ADV threshold inversely correlated with the volume fraction of emulsion at the lowest excitation frequency. However, at higher frequencies, possibly due to the high acoustic reflectivity of the PFC emulsions, the ADV threshold correlated directly with the volume fraction of the emulsion. Additionally, the ADV efficiency correlated with the supra-threshold acoustic pressure. Overall, these results elucidate fundamental acoustic properties of the ARSs, which can be used in future applications.
Collapse
Affiliation(s)
- Mitra Aliabouzar
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA
| | - Xiaofang Lu
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA
| | - Oliver D Kripfgans
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA; Applied Physics Program, University of Michigan, Ann Arbor, Michigan, USA; Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - J Brian Fowlkes
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA; Applied Physics Program, University of Michigan, Ann Arbor, Michigan, USA; Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Mario L Fabiilli
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA; Applied Physics Program, University of Michigan, Ann Arbor, Michigan, USA; Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
| |
Collapse
|
6
|
Mercado-Shekhar KP, Su H, Kalaikadal DS, Lorenz JN, Manglik RM, Holland CK, Redington AN, Haworth KJ. Acoustic droplet vaporization-mediated dissolved oxygen scavenging in blood-mimicking fluids, plasma, and blood. Ultrason Sonochem 2019; 56:114-124. [PMID: 31101245 PMCID: PMC6659737 DOI: 10.1016/j.ultsonch.2019.03.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 12/20/2018] [Accepted: 03/27/2019] [Indexed: 05/20/2023]
Abstract
Acoustic droplet vaporization (ADV) has been shown to reduce the partial pressure of oxygen (PO2) in a fluid. The goals of this study were three-fold: 1) to determine the ADV pressure amplitude threshold in fluids that had physiologically relevant values for surface tension, protein concentration, and viscosity; 2) to assess whether these parameters and fluid mixing affect ADV-mediated PO2 reduction; and 3) to assess the feasibility of ADV-mediated PO2 reduction in plasma and whole blood. In vitro ADV experiments were conducted using perfluoropentane droplets (number density: 5 × 106 ± 0.2 × 106/mL) dispersed in fluids (saline, polyvinylpyrrolidone solutions, porcine plasma, or porcine whole blood) that had a physiological range of surface tensions (62-68 mN/m), protein concentrations (0 and 68.7 mg/mL), and viscosities (0.7-4 cP). Droplets were exposed to pulsed ultrasound (5 MHz, 4.25 MPa peak negative pressure) while passing through a 37 °C flow system with inline PO2 sensors. In select experiments, the fluid also passed through mixing channels after ultrasound exposure. Our results revealed that the ADV pressure thresholds were the same for all fluids. Surface tension and protein concentration had no effect on PO2 reduction. Increasing viscosity attenuated PO2 reduction. However, the attenuated effect was absent after fluid mixing. Furthermore, ADV-mediated PO2 reduction in whole blood (30.8 ± 3.2 mmHg) was less than that in a polyvinylpyrrolidone solution (40.2 ± 2.1 mmHg) with equal viscosity. These findings should be considered when planning clinical studies of ADV-mediated PO2 reduction and other biomedical applications of ADV.
Collapse
Affiliation(s)
| | - Haili Su
- Department of Internal Medicine, University of Cincinnati, Cincinnati, OH, USA
| | - Deepak S Kalaikadal
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - John N Lorenz
- Department of Pharmacology and Systems Physiology, University of Cincinnati, Cincinnati, OH, USA
| | - Raj M Manglik
- Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - Christy K Holland
- Department of Internal Medicine, University of Cincinnati, Cincinnati, OH, USA; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - Andrew N Redington
- Division of Cardiology, The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Kevin J Haworth
- Department of Internal Medicine, University of Cincinnati, Cincinnati, OH, USA; Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA; Division of Cardiology, The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.
| |
Collapse
|
7
|
Teston E, Hingot V, Faugeras V, Errico C, Bezagu M, Tanter M, Couture O. A versatile and robust microfluidic device for capillary-sized simple or multiple emulsions production. Biomed Microdevices 2018; 20. [DOI: 10.1007/s10544-018-0340-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
8
|
Bezagu M, Clarhaut J, Renoux B, Monti F, Tanter M, Tabeling P, Cossy J, Couture O, Papot S, Arseniyadis S. In situ targeted activation of an anticancer agent using ultrasound-triggered release of composite droplets. Eur J Med Chem 2017; 142:2-7. [DOI: 10.1016/j.ejmech.2017.03.057] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Revised: 03/22/2017] [Accepted: 03/24/2017] [Indexed: 12/14/2022]
|
9
|
Urban A, Golgher L, Brunner C, Gdalyahu A, Har-Gil H, Kain D, Montaldo G, Sironi L, Blinder P. Understanding the neurovascular unit at multiple scales: Advantages and limitations of multi-photon and functional ultrasound imaging. Adv Drug Deliv Rev 2017; 119:73-100. [PMID: 28778714 DOI: 10.1016/j.addr.2017.07.018] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Revised: 07/17/2017] [Accepted: 07/22/2017] [Indexed: 02/07/2023]
Abstract
Developing efficient brain imaging technologies by combining a high spatiotemporal resolution and a large penetration depth is a key step for better understanding the neurovascular interface that emerges as a main pathway to neurodegeneration in many pathologies such as dementia. This review focuses on the advances in two complementary techniques: multi-photon laser scanning microscopy (MPLSM) and functional ultrasound imaging (fUSi). MPLSM has become the gold standard for in vivo imaging of cellular dynamics and morphology, together with cerebral blood flow. fUSi is an innovative imaging modality based on Doppler ultrasound, capable of recording vascular brain activity over large scales (i.e., tens of cubic millimeters) at unprecedented spatial and temporal resolution for such volumes (up to 10μm pixel size at 10kHz). By merging these two technologies, researchers may have access to a more detailed view of the various processes taking place at the neurovascular interface. MPLSM and fUSi are also good candidates for addressing the major challenge of real-time delivery, monitoring, and in vivo evaluation of drugs in neuronal tissue.
Collapse
Affiliation(s)
- Alan Urban
- Neuroelectronics Research Flanders, Leuven, Belgium; VIB, Leuven, Belgium and/or IMEC, Leuven, Belgium; Department of Neurosciences, KU Leuven, Leuven, Belgium; Neurobiology Dept., Wise Faculty of Life Sciences, Tel-Aviv University, Tel-Aviv, Israel
| | - Lior Golgher
- Sagol School of Neuroscience, Tel-Aviv University, Tel-Aviv, Israel
| | - Clément Brunner
- Neuroelectronics Research Flanders, Leuven, Belgium; VIB, Leuven, Belgium and/or IMEC, Leuven, Belgium
| | - Amos Gdalyahu
- Neurobiology Dept., Wise Faculty of Life Sciences, Tel-Aviv University, Tel-Aviv, Israel
| | - Hagai Har-Gil
- Sagol School of Neuroscience, Tel-Aviv University, Tel-Aviv, Israel
| | - David Kain
- Neurobiology Dept., Wise Faculty of Life Sciences, Tel-Aviv University, Tel-Aviv, Israel
| | - Gabriel Montaldo
- Neuroelectronics Research Flanders, Leuven, Belgium; VIB, Leuven, Belgium and/or IMEC, Leuven, Belgium
| | - Laura Sironi
- Physics Dept., Universita degli Studi di Milano Bicocca, Italy
| | - Pablo Blinder
- Neurobiology Dept., Wise Faculty of Life Sciences, Tel-Aviv University, Tel-Aviv, Israel; Sagol School of Neuroscience, Tel-Aviv University, Tel-Aviv, Israel.
| |
Collapse
|
10
|
Moncion A, Arlotta KJ, O’Neill EG, Lin M, Mohr LA, Franceschi RT, Kripfgans OD, Putnam AJ, Fabiilli ML. In vitro and in vivo assessment of controlled release and degradation of acoustically responsive scaffolds. Acta Biomater 2016; 46:221-233. [PMID: 27686040 DOI: 10.1016/j.actbio.2016.09.026] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2016] [Revised: 08/30/2016] [Accepted: 09/19/2016] [Indexed: 12/14/2022]
Abstract
Spatiotemporally controlled release of growth factors (GFs) is critical for regenerative processes such as angiogenesis. A common strategy is to encapsulate the GF within hydrogels, with release being controlled via diffusion and/or gel degradation (i.e., hydrolysis and/or proteolysis). However, simple encapsulation strategies do not provide spatial or temporal control of GF delivery, especially non-invasive, on-demand controlled release post implantation. We previously demonstrated that fibrin hydrogels, which are widely used in tissue engineering and GF delivery applications, can be doped with perfluorocarbon emulsion, thus yielding an acoustically responsive scaffold (ARS) that can be modulated with focused ultrasound, specifically via a mechanism termed acoustic droplet vaporization. This study investigates the impact of ARS and ultrasound properties on controlled release of a surrogate payload (i.e., fluorescently-labeled dextran) and fibrin degradation in vitro and in vivo. Ultrasound exposure (2.5MHz, peak rarefactional pressure: 8MPa, spatial peak time average intensity: 86.4mW/cm2), generated up to 7.7 and 21.7-fold increases in dextran release from the ARSs in vitro and in vivo, respectively. Ultrasound also induced morphological changes in the ARS. Surprisingly, up to 2.9-fold greater blood vessel density was observed in ARSs compared to fibrin when implanted subcutaneously, even without delivery of pro-angiogenic GFs. The results demonstrate the potential utility of ARSs in generating controlled release for tissue regeneration. STATEMENT OF SIGNIFICANCE Simple encapsulation of a molecular payload within a conventional hydrogel scaffold does not provide spatial or temporal control of payload release. Yet, spatiotemporally controlled release of bioactive payloads is critical for tissue regeneration, which often utilizes hydrogel scaffolds to facilitate processes such as angiogenesis. This work investigates the design and performance (both in vitro and in vivo) of hydrogel scaffolds where release of a fluorescent payload is non-invasively and spatiotemporally-controlled using focused ultrasound. We also quantitatively characterize the degradation and vascularization of the scaffolds. Our results may be of interest to groups working on controlled release strategies for implants, especially within the field of tissue engineering.
Collapse
|
11
|
Keravnou CP, De Cock I, Lentacker I, Izamis ML, Averkiou MA. Microvascular Injury and Perfusion Changes Induced by Ultrasound and Microbubbles in a Machine-Perfused Pig Liver. Ultrasound Med Biol 2016; 42:2676-2686. [PMID: 27554068 DOI: 10.1016/j.ultrasmedbio.2016.06.025] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 06/10/2016] [Accepted: 06/21/2016] [Indexed: 06/06/2023]
Abstract
Localized drug delivery and uptake can benefit from the combined action of ultrasound and microbubbles at a specific site. Some of the possible mechanisms suggested are vessel poration and/or cell poration, but the exact acoustic parameters that trigger those phenomena remain unknown. Ex vivo machine perfusion of human-sized organs is a technique that provides an ideal environment for pre-clinical investigations with high physiologic relevance not possible with in vitro experiments. In this work, ex vivo machine-perfused pig livers were combined with an image-guided therapy system to investigate microvascular flow changes caused by the interaction of ultrasound-driven microbubbles with the vasculature. The effects of acoustic pressure (1.7-4 MPa peak negative pressures) and number of cycles (1000 or 20 cycles) were examined. Perfusion changes caused by the action of ultrasound on microbubbles in the microcirculation were qualitatively and quantitatively assessed with contrast-enhanced ultrasound and used as a metric of the extent of vessel perforation, thus, extravasation. Areas that were exposed to peak negative pressures above 1.7 MPa underwent a detectable and irreversible perfusion change. Complete devascularization of the area exposed to ultrasound was observed at much larger acoustic pressures (∼4 MPa). Shorter acoustic pulses (20 cycles) produced markedly fewer perfusion changes than longer pulses (1000 cycles) under the same acoustic amplitude exposure.
Collapse
Affiliation(s)
- Christina P Keravnou
- Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus; Department of Bioengineering, University of Washington, Seattle, Washington, USA
| | - Ine De Cock
- Department of Bioengineering, University of Washington, Seattle, Washington, USA; Laboratory for General Biochemistry and Physical Pharmacy, Ghent University, Ghent, Belgium
| | - Ine Lentacker
- Laboratory for General Biochemistry and Physical Pharmacy, Ghent University, Ghent, Belgium
| | - Maria-Louisa Izamis
- Department of Mechanical and Manufacturing Engineering, University of Cyprus, Nicosia, Cyprus
| | | |
Collapse
|
12
|
Sheeran PS, Daghighi Y, Yoo K, Williams R, Cherin E, Foster FS, Burns PN. Image-Guided Ultrasound Characterization of Volatile Sub-Micron Phase-Shift Droplets in the 20-40 MHz Frequency Range. Ultrasound Med Biol 2016; 42:795-807. [PMID: 26725168 DOI: 10.1016/j.ultrasmedbio.2015.11.012] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2015] [Revised: 11/02/2015] [Accepted: 11/12/2015] [Indexed: 05/09/2023]
Abstract
Phase-shift perfluorocarbon droplets are designed to convert from the liquid to the gas state by the external application of acoustic or optical energy. Although droplet vaporization has been investigated extensively at ultrasonic frequencies between 1 and 10 MHz, few studies have characterized performance at the higher frequencies commonly used in small animal imaging. In this study, we use standard B-mode imaging sequences on a pre-clinical ultrasound platform to both image and activate sub-micron decafluorobutane droplet populations in vitro and in vivo at center frequencies in the range of 20-40 MHz. Results show that droplets remain stable against vaporization at low imaging pressures but are vaporized at peak negative pressures near 3.5 MPa at the three frequencies tested. This study also found that a small number of size outliers present in the distribution can greatly influence droplet performance. Removal of these outliers results in a more accurate assessment of the vaporization threshold and produces free-flowing microbubbles upon vaporization in the mouse kidney.
Collapse
Affiliation(s)
- Paul S Sheeran
- Physical Sciences Department, Sunnybrook Research Institute, Toronto, ON, Canada; Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada.
| | - Yasaman Daghighi
- Physical Sciences Department, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Kimoon Yoo
- Physical Sciences Department, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Ross Williams
- Physical Sciences Department, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Emmanuel Cherin
- Physical Sciences Department, Sunnybrook Research Institute, Toronto, ON, Canada
| | - F Stuart Foster
- Physical Sciences Department, Sunnybrook Research Institute, Toronto, ON, Canada; Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
| | - Peter N Burns
- Physical Sciences Department, Sunnybrook Research Institute, Toronto, ON, Canada; Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
13
|
Sheeran PS, Rojas JD, Puett C, Hjelmquist J, Arena CB, Dayton PA. Contrast-enhanced ultrasound imaging and in vivo circulatory kinetics with low-boiling-point nanoscale phase-change perfluorocarbon agents. Ultrasound Med Biol 2015; 41:814-31. [PMID: 25619781 PMCID: PMC5599113 DOI: 10.1016/j.ultrasmedbio.2014.10.020] [Citation(s) in RCA: 76] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Revised: 10/23/2014] [Accepted: 10/24/2014] [Indexed: 05/03/2023]
Abstract
Many studies have explored phase-change contrast agents (PCCAs) that can be vaporized by an ultrasonic pulse to form microbubbles for ultrasound imaging and therapy. However, few investigations have been published on the utility and characteristics of PCCAs as contrast agents in vivo. In this study, we examine the properties of low-boiling-point nanoscale PCCAs evaluated in vivo and compare data with those for conventional microbubbles with respect to contrast generation and circulation properties. To do this, we develop a custom pulse sequence to vaporize and image PCCAs using the Verasonics research platform and a clinical array transducer. Results indicate that droplets can produce contrast enhancement similar to that of microbubbles (7.29 to 18.24 dB over baseline, depending on formulation) and can be designed to circulate for as much as 3.3 times longer than microbubbles. This study also reports for the first time the ability to capture contrast washout kinetics of the target organ as a measure of vascular perfusion.
Collapse
Affiliation(s)
- Paul S Sheeran
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Juan D Rojas
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Connor Puett
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Jordan Hjelmquist
- Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Christopher B Arena
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA.
| |
Collapse
|
14
|
Abstract
We present a comprehensive study of the step-emulsification process for high-throughput production of colloidal monodisperse droplets. The 'microfluidic step emulsifier' combines a shallow microchannel operating with two co-flowing immiscible fluids and an abrupt (step-like) opening to a deep and wide reservoir. Based on Hele-Shaw hydrodynamics, we determine the quasi-static shape of the fluid interface prior to transition to oscillatory step-emulsification at low capillary numbers. The theoretically derived transition threshold yields an excellent agreement with experimental data. A closed-form expression for the size of the droplets generated in the step-emulsification regime and derived using geometric arguments also shows a very good agreement with the experiment.
Collapse
Affiliation(s)
- Z Li
- MMN, CNRS, ESPCI Paris-Tech, 10 rue Vauquelin, 75005 Paris, France
| | | | | | | | | |
Collapse
|
15
|
Reznik N, Lajoinie G, Shpak O, Gelderblom EC, Williams R, de Jong N, Versluis M, Burns PN. On the acoustic properties of vaporized submicron perfluorocarbon droplets. Ultrasound Med Biol 2014; 40:1379-84. [PMID: 24462162 DOI: 10.1016/j.ultrasmedbio.2013.11.025] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2013] [Revised: 11/19/2013] [Accepted: 11/20/2013] [Indexed: 05/22/2023]
Abstract
The acoustic characteristics of microbubbles created from vaporized submicron perfluorocarbon droplets with fluorosurfactant coating are examined. Utilizing ultra-high-speed optical imaging, the acoustic response of individual microbubbles to low-intensity diagnostic ultrasound was observed on clinically relevant time scales of hundreds of milliseconds after vaporization. It was found that the vaporized droplets oscillate non-linearly and exhibit a resonant bubble size shift and increased damping relative to uncoated gas bubbles due to the presence of coating material. Unlike the commercially available lipid-coated ultrasound contrast agents, which may exhibit compression-only behavior, vaporized droplets may exhibit expansion-dominated oscillations. It was further observed that the non-linearity of the acoustic response of the bubbles was comparable to that of SonoVue microbubbles. These results suggest that vaporized submicron perfluorocarbon droplets possess the acoustic characteristics necessary for their potential use as ultrasound contrast agents in clinical practice.
Collapse
Affiliation(s)
- Nikita Reznik
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
| | - Guillaume Lajoinie
- Physics of Fluids Group and MIRA Institute of Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
| | - Oleksandr Shpak
- Physics of Fluids Group and MIRA Institute of Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
| | - Erik C Gelderblom
- Physics of Fluids Group and MIRA Institute of Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
| | - Ross Williams
- Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Nico de Jong
- Biomedical Engineering Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Michel Versluis
- Physics of Fluids Group and MIRA Institute of Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
| | - Peter N Burns
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada; Sunnybrook Research Institute, Toronto, Ontario, Canada
| |
Collapse
|
16
|
Abstract
Although the use of ultrasonic plane-wave transmissions rather than line-per-line focused beam transmissions has been long studied in research, clinical application of this technology was only recently made possible through developments in graphical processing unit (GPU)-based platforms. Far beyond a technological breakthrough, the use of plane or diverging wave transmissions enables attainment of ultrafast frame rates (typically faster than 1000 frames per second) over a large field of view. This concept has also inspired the emergence of completely novel imaging modes which are valuable for ultrasound-based screening, diagnosis, and therapeutic monitoring. In this review article, we present the basic principles and implementation of ultrafast imaging. In particular, present and future applications of ultrafast imaging in biomedical ultrasound are illustrated and discussed.
Collapse
|
17
|
Tabeling P. Recent progress in the physics of microfluidics and related biotechnological applications. Curr Opin Biotechnol 2013; 25:129-34. [PMID: 24484891 DOI: 10.1016/j.copbio.2013.11.009] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2013] [Revised: 11/18/2013] [Accepted: 11/25/2013] [Indexed: 10/25/2022]
Abstract
Since the mid-nineties, the physical understanding of microfluidic flows has reached a level sufficiently elaborate for envisaging applications in all sorts of domains. As the domain expanded, the existence of new situations where fluid dynamics at small or moderate Reynolds numbers combines with confinement, interfaces, transport, particles along with disordered substrates raised new challenges. The present review is restricted to three domains in which progress in the physical description has been made recently (droplet-based, inertial and paper-based microfluidics) and for which biotechnological applications are foreseeable.
Collapse
|
18
|
Fabiilli ML, Piert MR, Koeppe RA, Sherman PS, Quesada CA, Kripfgans OD. Assessment of the biodistribution of an [(18) F]FDG-loaded perfluorocarbon double emulsion using dynamic micro-PET in rats. Contrast Media Mol Imaging 2013; 8:366-74. [PMID: 23613440 DOI: 10.1002/cmmi.1532] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2012] [Revised: 12/17/2012] [Accepted: 01/04/2013] [Indexed: 12/11/2022]
Abstract
Perfluorocarbon (PFC) double emulsions loaded with a water-soluble, therapeutic agent can be triggered by ultrasound in a process known as acoustic droplet vaporization. Elucidating the stability and biodistribution of these sonosensitive vehicles and encapsulated agents is critical in developing targeted drug delivery strategies using ultrasound. [(18) F]fluorodeoxyglucose (FDG) was encapsulated in a PFC double emulsion and the in vitro diffusion of FDG was assessed using a Franz diffusion cell. Using dynamic micro-positron emission tomography and direct tissue sampling, the biodistribution of FDG administered as a solution (i.e. non-emulsified) or as an emulsion was studied in Fisher 344 rats (n = 6) bearing subcutaneous 9L gliosarcoma. Standardized uptake values (SUVs) and area under the curve of the SUV (AUCSUV ) of FDG were calculated for various tissues. The FDG flux from the emulsion decreased by up to a factor of 6.9 compared with the FDG solution. FDG uptake, calculated from the AUCSUV , decreased by 36% and 44% for brain and tumor, respectively, when comparing FDG solution vs FDG emulsion (p < 0.01). Decreases in AUCSUV in highly metabolic tissues such as brain and tumor demonstrated retention of FDG within the double emulsion. No statistically significant differences in lung AUCSUV were observed, suggesting minimal accumulation of the emulsion in the pulmonary capillary bed. The liver AUCSUV increased by 356% for the FDG emulsion, thus indicating significant hepatic retention of the emulsion.
Collapse
Affiliation(s)
- Mario L Fabiilli
- Department of Radiology, University of Michigan, Ann Arbor, MI, USA.
| | | | | | | | | | | |
Collapse
|
19
|
Reznik N, Shpak O, Gelderblom EC, Williams R, de Jong N, Versluis M, Burns PN. The efficiency and stability of bubble formation by acoustic vaporization of submicron perfluorocarbon droplets. Ultrasonics 2013; 53:1368-76. [PMID: 23652262 DOI: 10.1016/j.ultras.2013.04.005] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2012] [Revised: 02/10/2013] [Accepted: 04/03/2013] [Indexed: 05/13/2023]
Abstract
Submicron droplets of liquid perfluorocarbon converted into microbubbles with applied ultrasound have been studied, for a number of years, as potential next generation extravascular ultrasound contrast agents. In this work, we conduct an initial ultra-high-speed optical imaging study to examine the vaporization of submicron droplets and observe the newly created microbubbles in the first microseconds after vaporization. It was estimated that single pulses of ultrasound at 10 MHz with pressures within the diagnostic range are able to vaporize on the order of at least 10% of the exposed droplets. However, only part of the newly created microbubbles survives immediately following vaporization - the bubbles may recondense back into the liquid droplet state within microseconds of nucleation. The probability of bubble survival within the first microseconds of vaporization was shown to depend on ultrasound excitation pressure as well as on bubble coalescence during vaporization, a behavior influenced by the presence of coating material on the newly created bubbles. The results of this study show for the first time that although initial vaporization of droplets is necessary to create echogenic bubbles, additional factors, such as coalescence and bubble shell properties, are important and should be carefully considered for the production of microbubbles for use in medical imaging.
Collapse
Affiliation(s)
- Nikita Reznik
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada.
| | | | | | | | | | | | | |
Collapse
|
20
|
Fabiilli ML, Wilson CG, Padilla F, Martín-Saavedra FM, Fowlkes JB, Franceschi RT. Acoustic droplet-hydrogel composites for spatial and temporal control of growth factor delivery and scaffold stiffness. Acta Biomater 2013; 9:7399-409. [PMID: 23535233 DOI: 10.1016/j.actbio.2013.03.027] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2012] [Revised: 01/29/2013] [Accepted: 03/13/2013] [Indexed: 10/27/2022]
Abstract
Wound healing is regulated by temporally and spatially restricted patterns of growth factor signaling, but there are few delivery vehicles capable of the "on-demand" release necessary for recapitulating these patterns. Recently we described a perfluorocarbon double emulsion that selectively releases a protein payload upon exposure to ultrasound through a process known as acoustic droplet vaporization (ADV). In this study, we describe a delivery system composed of fibrin hydrogels doped with growth factor-loaded double emulsion for applications in tissue regeneration. Release of immunoreactive basic fibroblast growth factor (bFGF) from the composites increased up to 5-fold following ADV and delayed release was achieved by delaying exposure to ultrasound. Releasates of ultrasound-treated materials significantly increased the proliferation of endothelial cells compared to sham controls, indicating that the released bFGF was bioactive. ADV also triggered changes in the ultrastructure and mechanical properties of the fibrin as bubble formation and consolidation of the fibrin in ultrasound-treated composites were accompanied by up to a 22-fold increase in shear stiffness. ADV did not reduce the viability of cells suspended in composite scaffolds. These results demonstrate that an acoustic droplet-hydrogel composite could have broad utility in promoting wound healing through on-demand control of growth factor release and/or scaffold architecture.
Collapse
|
21
|
Sheeran PS, Matsunaga TO, Dayton PA. Phase-transition thresholds and vaporization phenomena for ultrasound phase-change nanoemulsions assessed via high-speed optical microscopy. Phys Med Biol 2013; 58:4513-34. [PMID: 23760161 DOI: 10.1088/0031-9155/58/13/4513] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Ultrasonically activated phase-change contrast agents (PCCAs) based on perfluorocarbon droplets have been proposed for a variety of therapeutic and diagnostic clinical applications. When generated at the nanoscale, droplets may be small enough to exit the vascular space and then be induced to vaporize with high spatial and temporal specificity by externally-applied ultrasound. The use of acoustical techniques for optimizing ultrasound parameters for given applications can be a significant challenge for nanoscale PCCAs due to the contributions of larger outlier droplets. Similarly, optical techniques can be a challenge due to the sub-micron size of nanodroplet agents and resolution limits of optical microscopy. In this study, an optical method for determining activation thresholds of nanoscale emulsions based on the in vitro distribution of bubbles resulting from vaporization of PCCAs after single, short (<10 cycles) ultrasound pulses is evaluated. Through ultra-high-speed microscopy it is shown that the bubbles produced early in the pulse from vaporized droplets are strongly affected by subsequent cycles of the vaporization pulse, and these effects increase with pulse length. Results show that decafluorobutane nanoemulsions with peak diameters on the order of 200 nm can be optimally vaporized with short pulses using pressures amenable to clinical diagnostic ultrasound machines.
Collapse
Affiliation(s)
- Paul S Sheeran
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, NC 27599, USA
| | | | | |
Collapse
|