Javadi H, Mahmoud-Pashazadeh A, Mogharrabi M, Iranpour D, Amini A, Pourbehi M, Akbarzadeh M, Nabipour I, Assadi M. Comparison of 180° and 360° Arc Data Acquisition to Measure Scintigraphic Parameters from Gated Single Photon Emission Computed Tomography Myocardial Perfusion Imaging: Is There Any Difference?
Mol Imaging Radionucl Ther 2016;
25:26-31. [PMID:
27299285 PMCID:
PMC4807346 DOI:
10.4274/mirt.96720]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Objective:
The aim of the current study was to compare 180° and 360° data collection modes to measure end diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) values of the cardiac system by gated myocardial perfusion tomography.
Methods:
Thirty-three patients underwent gated myocardial perfusion tomography. Single photon emission computed tomography data of patients’ heart were acquired by 180°, 45° left posterior oblique to 45° right anterior oblique, and 360° to obtain EDV, ESV, EF and cardiac volume changes (V1, V2, V3, V4, V5, V6, V7 and V8) throughout each cardiac cycle.
Results:
Results of the current study indicated that there were no significant differences between 180° and 360° angular sampling in terms of measuring EDV, ESV and EF in myocardial perfusion imaging. Cardiac volume change patterns during a cardiac cycle were also similar in 360° and 180° scans. We also observed that there was no difference in EDV, ESV and EF values between the group with stress induced by exercise and the group with stress imposed by dipyridamole.
Conclusion:
As there is no difference between 180°and 360° cardiac scanning in terms of EDV, ESV and EF, half-orbit scan is recommended to study these cardiac system parameters because it offers more comfort to patients and a shorter scanning time.