1
|
Freire IS, Lopes TS, Afonso SG, Pereira DJ. From images to insights: a neuroradiologist's practical guide on white matter fiber tract anatomy and DTI patterns for pre-surgical planning. Neuroradiology 2024:10.1007/s00234-024-03362-7. [PMID: 38635028 DOI: 10.1007/s00234-024-03362-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Accepted: 04/13/2024] [Indexed: 04/19/2024]
Abstract
INTRODUCTION Diffusion tensor imaging (DTI) is a valuable non-invasive imaging modality for mapping white matter tracts and assessing microstructural integrity, and can be used as a "biomarker" in diagnosis, differentiation, and therapeutic monitoring. Although it has gained clinical importance as a marker of neuropathology, limitations in its interpretation underscore the need for caution. METHODS This review provides an overview of the principles and clinical applicability of DTI. We focus on major white matter fiber bundles, detailing their normal anatomy and pathological DTI patterns, with emphasis on tracts routinely requested in our neurosurgical department in the preoperative context (uncinate fasciculus, arcuate fasciculus, pyramidal pathway, optic radiation, and dentatorubrothalamic tract). RESULTS We guide neuroradiologists and neurosurgeons in defining volumes of interest for mapping individual tracts and demonstrating their 3D reconstructions. The intricate trajectories of white matter tracts pose a challenge for accurate fiber orientation recording, with each bundle exhibiting specific characteristics. Tracts adjacent to brain lesions are categorized as displaced, edematous, infiltrated, or disrupted, illustrated with clinical cases of brain neoplasms. To improve structured reporting, we propose a checklist of topics for inclusion in imaging evaluations and MRI reports. CONCLUSION DTI is emerging as a powerful tool for assessing microstructural changes in brain disorders, despite some challenges in standardization and interpretation. This review serves an educational purpose by providing guidance for fiber monitoring and interpretation of pathological patterns observed in clinical cases, highlighting the importance and potential pitfalls of DTI in neuroradiology and surgical planning.
Collapse
Affiliation(s)
- Inês S Freire
- Department of Neuroradiology - Centro Hospitalar Universitário de Lisboa Central (CHULC), Rua José António Serrano, 1150-199, Lisbon, Portugal.
- NOVA Medical School, Universidade Nova de Lisboa, Lisbon, Portugal.
| | - Tânia S Lopes
- Institute of Nuclear Sciences Applied to Health (ICNAS), Coimbra, Portugal
- Coimbra Institute for Biomedical Imaging and Translational Research (CIBIT), Coimbra, Portugal
| | - Sónia G Afonso
- Institute of Nuclear Sciences Applied to Health (ICNAS), Coimbra, Portugal
- Coimbra Institute for Biomedical Imaging and Translational Research (CIBIT), Coimbra, Portugal
| | - Daniela J Pereira
- Institute of Nuclear Sciences Applied to Health (ICNAS), Coimbra, Portugal
- Coimbra Institute for Biomedical Imaging and Translational Research (CIBIT), Coimbra, Portugal
- Functional Unit of Neuroradiology - Centro Hospitalar e Universitário de Coimbra (CHUC), Coimbra, Portugal
| |
Collapse
|
2
|
Zhong J, Liu X, Hu Y, Xing Y, Ding D, Ge X, Song Y, Wang S, Chen L, Zhu Y, Lu W, Zhang H, Yao W. Robustness of Quantitative Diffusion Metrics from Four Models: A Prospective Study on the Influence of Scan-Rescans, Voxel Size, Coils, and Observers. J Magn Reson Imaging 2023. [PMID: 38112305 DOI: 10.1002/jmri.29192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 12/01/2023] [Accepted: 12/02/2023] [Indexed: 12/21/2023] Open
Abstract
BACKGROUND Quantitative diffusion metrics provide additional microstructural information of diseases. The robustness of quantitative diffusion metrics should be established before clinical application. PURPOSE To evaluate the variability and reproducibility of quantitative diffusion MRI metrics. STUDY TYPE Prospective. POPULATION 14 volunteers (7 men; median age, range, 28, 26-59 years). FIELD STRENGTH/SEQUENCE 3.0-T/Diffusion spectrum imaging. ASSESSMENT Brain MRI studies were performed four times per subject: involving different combinations of coil types and voxel sizes. Regions of interest of 13 brain anatomical sites were drawn by one observer twice and another observer once to allow interobserver and intraobserver reproducibility assessment. Twenty-five quantitative metrics were calculated using four diffusion models. STATISTICAL TESTS The variability was evaluated with coefficients of variation (CV), and quartile coefficient of dispersion (QCD). The reproducibility was assessed with intraclass correlation coefficient (ICC), and concordance correlation coefficient (CCC). Wilcoxon signed rank test was used to compare the influence of factors on robustness of quantitative diffusion metrics. A two-tailed P < 0.05 was considered statistically significant. RESULTS The variability of quantitative diffusion metrics showed CV of 2.4%-68.2%, and QCD of 0.6%-48.2%, respectively. The reproducibility of scans using 20-channel coils with voxels of 2 × 2 × 2 mm3 and 3 × 3 × 3 mm3 , respectively (ICC 0.03-0.84, CCC 0.03-0.84) was significantly worse than that of repeated scans using a 20-channel coil with a voxel size of 2 × 2 × 2 mm3 (ICC of 0.74-0.97, CCC 0.74-0.97) and that of scans using 20- and 64-channel coils, respectively, with a voxel size of 2 × 2 × 2 mm3 (ICC 0.59-0.95, CCC 0.59-0.95). The intraobserver reproducibility (ICC 0.49-0.94, CCC 0.49-0.94) was significantly better than the interobserver reproducibility (ICC 0.28-0.91, CCC 0.28-0.91). DATA CONCLUSION Our study indicated that the voxel size has a greater influence on the reproducibility of quantitative diffusion metrics than scan-rescans and coils. The reproducibility within one observer was higher than that between two observers. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Jingyu Zhong
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xianwei Liu
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yangfan Hu
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yue Xing
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Defang Ding
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xiang Ge
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yang Song
- MR Scientific Marketing, Siemens Healthineers Ltd, Shanghai, China
| | - Silian Wang
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Liwei Chen
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Ying Zhu
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Wenjie Lu
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Huan Zhang
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Weiwu Yao
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
3
|
Petter E, Scheibenbogen C, Linz P, Stehning C, Wirth K, Kuehne T, Kelm M. Muscle sodium content in patients with Myalgic Encephalomyelitis/Chronic Fatigue Syndrome. J Transl Med 2022; 20:580. [PMID: 36494667 PMCID: PMC9733289 DOI: 10.1186/s12967-022-03616-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Accepted: 08/25/2022] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Muscle fatigue and pain are key symptoms of Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS). Although the pathophysiology is not yet fully understood, there is ample evidence for hypoperfusion which may result in electrolyte imbalance and sodium overload in muscles. Therefore, the aim of this study was to assess levels of sodium content in muscles of patients with ME/CFS and to compare these to healthy controls. METHODS Six female patients with ME/CFS and six age, BMI and sex matched controls underwent 23Na-MRI of the left lower leg using a clinical 3T MR scanner before and after 3 min of plantar flexion exercise. Sodium reference phantoms with solutions of 10, 20, 30 and 40 mmol/L NaCl were used for quantification. Muscle sodium content over 40 min was measured using a dedicated plugin in the open-source DICOM viewer Horos. Handgrip strength was measured and correlated with sodium content. RESULTS Baseline tissue sodium content was higher in all 5 lower leg muscle compartments in ME/CFS compared to controls. Within the anterior extensor muscle compartment, the highest difference in baseline muscle sodium content between ME/CFS and controls was found (mean ± SD; 12.20 ± 1.66 mM in ME/CFS versus 9.38 ± 0.71 mM in controls, p = 0.0034). Directly after exercise, tissue sodium content increased in gastrocnemius and triceps surae muscles with + 30% in ME/CFS (p = 0.0005) and + 24% in controls (p = 0.0007) in the medial gastrocnemius muscle but not in the extensor muscles which were not exercised. Compared to baseline, the increase of sodium content in medial gastrocnemius muscle was stronger in ME/CFS than in controls with + 30% versus + 17% to baseline at 12 min (p = 0.0326) and + 29% versus + 16% to baseline at 15 min (p = 0.0265). Patients had reduced average handgrip strength which was associated with increased average muscle tissue sodium content (p = 0.0319, R2 = 0.3832). CONCLUSION Muscle sodium content before and after exercise was higher in ME/CFS than in healthy controls. Furthermore, our findings indicate an inverse correlation between muscle sodium content and handgrip strength. These findings provide evidence that sodium overload may play a role in the pathophysiology of ME/CFS and may allow for potential therapeutic targeting.
Collapse
Affiliation(s)
- Elisabeth Petter
- grid.6363.00000 0001 2218 4662Institute of Medical Immunology, Charité Universitätsmedizin Berlin, Campus Virchow, Berlin, Germany ,grid.6363.00000 0001 2218 4662Institute of Computer-Assisted Cardiovascular Medicine, Charité Universitätsmedizin Berlin, Berlin, Germany ,grid.418209.60000 0001 0000 0404Department of Congenital Heart Disease, German Heart Center Berlin, Berlin, Germany
| | - Carmen Scheibenbogen
- grid.6363.00000 0001 2218 4662Institute of Medical Immunology, Charité Universitätsmedizin Berlin, Campus Virchow, Berlin, Germany
| | - Peter Linz
- grid.411668.c0000 0000 9935 6525Institute of Radiology, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
| | | | - Klaus Wirth
- Institute of General Pharmacology and Toxicology, University Hospital Frankfurt am Main, Goethe-University, Theodor-Stern Kai 7, Frankfurt am Main, Germany
| | - Titus Kuehne
- grid.6363.00000 0001 2218 4662Institute of Computer-Assisted Cardiovascular Medicine, Charité Universitätsmedizin Berlin, Berlin, Germany ,grid.418209.60000 0001 0000 0404Department of Congenital Heart Disease, German Heart Center Berlin, Berlin, Germany
| | - Marcus Kelm
- grid.6363.00000 0001 2218 4662Institute of Computer-Assisted Cardiovascular Medicine, Charité Universitätsmedizin Berlin, Berlin, Germany ,grid.418209.60000 0001 0000 0404Department of Congenital Heart Disease, German Heart Center Berlin, Berlin, Germany ,grid.484013.a0000 0004 6879 971XBerlin Institute of Health (BIH), Berlin, Germany ,grid.452396.f0000 0004 5937 5237German Centre for Cardiovascular Research (DZHK),
Partner Site, Berlin, Germany
| |
Collapse
|
4
|
Wu P, Huang C, Shi B, Jin A. Comparison of region-of-interest delineation methods for diffusion tensor imaging in patients with cervical spondylotic radiculopathy. BMC Musculoskelet Disord 2022; 23:677. [PMID: 35840941 PMCID: PMC9284815 DOI: 10.1186/s12891-022-05639-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Accepted: 07/06/2022] [Indexed: 11/20/2022] Open
Abstract
Background Diffusion tensor imaging is a promising technique for determining the responsible lesion of cervical radiculopathy, but the selection and delineation of the region of interest (ROI) affect the results. This study explored the impact of different ROI sketching methods on the repeatability and consistency of DTI measurement values in patients with cervical spondylotic radiculopathy (CSR). Methods This retrospective study included CSR patients who underwent DTI imaging. The images were analyzed independently by two radiologists. Four delineation methods were used: freehand method, maximum roundness, quadrilateral method, and multi-point averaging method. They re-examined the images 6 weeks later. The intra-class correlation coefficient (ICC) was used to investigate the consistency between the two measurements and the reproducibility between two radiologists. Results Forty-two CSR patients were included in this study. The distribution of the compressed nerve roots was five C4, eight C5, sixteen C6, eleven C7, and two C8. No differences were found among the four methods in fractional anisotropy (FA) or apparent diffusion coefficient (ADC), irrespective of radiologists (all P>0.05). Similar results were observed between the first and second measurements (all P>0.05), but some significant differences were observed for radiologist 2 for the four-small rounds method (P=0.033). The freehand and single largest circle methods were the two methods with the highest ICC between the two measurements and the two radiologists (all ICC >0.90). Conclusion The freehand and single largest circle methods were the most consistent methods for delineating DTI ROI in patients with CSR.
Collapse
Affiliation(s)
- Penghuan Wu
- Shaoguan First People's Hospital, Affiliated Shaoguan First People's Hospital, Southern Medical University, Guangdong, China
| | - Chengyan Huang
- Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Benchao Shi
- Department of Spinal Surgery, Orthopedics Center, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Anmin Jin
- Department of Spinal Surgery, Orthopedics Center, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
| |
Collapse
|