1
|
Miyaji N, Miwa K, Iimori T. [Eye Lens Monitoring for Nuclear Medicine]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:1367-1375. [PMID: 36403970 DOI: 10.6009/jjrt.2022-2110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Affiliation(s)
- Noriaki Miyaji
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research
| | - Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University
| | | |
Collapse
|
2
|
Miyaji N, Miwa K, Iimori T, Wagatsuma K, Tsushima H, Yokotsuka N, Murata T, Kasahara T, Terauchi T. Determination of a reliable assessment for occupational eye lens dose in nuclear medicine. J Appl Clin Med Phys 2022; 23:e13713. [PMID: 35775691 PMCID: PMC9359038 DOI: 10.1002/acm2.13713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 05/31/2022] [Accepted: 06/14/2022] [Indexed: 11/29/2022] Open
Abstract
The most recent statement published by the International Commission on Radiological Protection describes a reduction in the maximum allowable occupational eye lens dose from 150 to 20 mSv/year (averaged over 5‐year periods). Exposing the eye lens to radiation is a concern for nuclear medicine staff who handle radionuclide tracers with various levels of photon energy. This study aimed to define the optimal dosimeter and means of measuring the amount of exposure to which the eye lens is exposed during a routine nuclear medicine practice. A RANDO human phantom attached to Glass Badge and Luminess Badge for body or neck, DOSIRIS and VISION for eyes, and nanoDot for body, neck, and eyes was exposed to 99mTc, 123I, and 18F radionuclides. Sealed syringe sources of each radionuclide were positioned 30 cm from the abdomen of the phantom. Estimated exposure based on measurement conditions (i.e., air kerma rate constants, conversion coefficient, distance, activity, and exposure time) was compared measured dose equivalent of each dosimeter. Differences in body, neck, and eye lens dosimeters were statistically analyzed. The 10‐mm dose equivalent significantly differed between the Glass Badge and Luminess Badge for the neck, but these were almost equivalent at the body. The 0.07‐mm dose equivalent for the nanoDot dosimeters was greatly overestimated compared to the estimated exposure of 99mTc and 123I radionuclides. Measured dose equivalents of exposure significantly differed between the body and eye lens dosimeters with respect to 18F. Although accurately measuring radiation exposure to the eye lenses of nuclear medicine staff is conventionally monitored using dosimeters worn on the chest or abdomen, eye lens dosimeters that provide a 3‐mm dose equivalent near the eye would be a more reliable means of assessing radiation doses in the mixed radiation environment of nuclear medicine.
Collapse
Affiliation(s)
- Noriaki Miyaji
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| | - Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Fukushima, Japan
| | - Takashi Iimori
- Department of Radiology, Chiba University Hospital, Chiba, Japan
| | - Kei Wagatsuma
- School of Allied Health Science, Kitasato University, Kanagawa, Japan
| | - Hiroyuki Tsushima
- Department of Radiological Technology, Faculty of Health Sciences, Kobe Tokiwa University, Hyogo, Japan
| | - Noriyo Yokotsuka
- Department of Radiological Technology, Faculty of Medical Technology, Teikyo University, Tokyo, Japan
| | - Taisuke Murata
- Department of Radiology, Chiba University Hospital, Chiba, Japan
| | | | - Takashi Terauchi
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| |
Collapse
|
3
|
Zuhayra M, Helm A, Ranjan J, Jüptner M, Zhao Y, Marx M, Assam I, Alfteimi A, Lützen U. A simple, reliable and accurate approach for assessing [ 131I]-capsule activity leading to significant reduction of radiation exposure of medical staff during radioiodine therapy. Phys Med 2022; 96:157-165. [PMID: 35306454 DOI: 10.1016/j.ejmp.2022.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 03/09/2022] [Accepted: 03/14/2022] [Indexed: 11/28/2022] Open
Abstract
PURPOSE According to German law, the [131I]-capsule activity has to be checked in the context of radioiodine therapy (RIT) immediately before application. The measurement leads to significant radiation exposure of the medical personnel, especially of their hands. We aimed to establish a method for estimating [131I]-capsule activity by measuring the dose rate (DR) at contact of the delivered lead closed container carrying the [131I]-capsules and to evaluate radiation exposure in comparison to conventional [131I]-capsule measurement using a dose calibrator. METHODS DR on the surface of the closed lead container was measured at two locations and correlated linearly with the [131I]-capsule activity measured in a dose calibrator to create calibrating curves. The hand and whole body (effective) doses were determined with official dose meters during validation of our method in clinical practice. RESULTS The determination coefficients (R2) of linear calibration curves were greater than 0.9974. The total relative uncertainty for estimating [131I]-capsule activity with our method was <±7.5% which is lower than the uncertainty of the nominal activity and quite close to the threshold limit for the maximum allowed uncertainty of ± 5% for measuring activity in radioactive drugs. The reduction of the hand dose caused by our method was 97% compared with the conventional measurements of the [131I]-capsules in a dose calibrator. CONCLUSION Measuring DR on the surface of the closed lead containers enables the [131I]-capsules activity to be estimated simply, reliably and with sufficient accuracy leading to significant reduction of the radiation exposure for the medical staff.
Collapse
Affiliation(s)
- Maaz Zuhayra
- Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Karl Lennert Cancer Center North, Feld-Str. 21, D-24105, Germany.
| | - Alexander Helm
- Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Karl Lennert Cancer Center North, Feld-Str. 21, D-24105, Germany.
| | - Joshua Ranjan
- Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Karl Lennert Cancer Center North, Feld-Str. 21, D-24105, Germany.
| | - Michael Jüptner
- Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Karl Lennert Cancer Center North, Feld-Str. 21, D-24105, Germany.
| | - Yi Zhao
- Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Karl Lennert Cancer Center North, Feld-Str. 21, D-24105, Germany.
| | - Marlies Marx
- Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Karl Lennert Cancer Center North, Feld-Str. 21, D-24105, Germany.
| | - Isong Assam
- Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Karl Lennert Cancer Center North, Feld-Str. 21, D-24105, Germany.
| | - Ammar Alfteimi
- Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Karl Lennert Cancer Center North, Feld-Str. 21, D-24105, Germany.
| | - Ulf Lützen
- Department of Nuclear Medicine, Molecular Diagnostic Imaging and Therapy, University Hospital of Schleswig-Holstein (UKSH), Karl Lennert Cancer Center North, Feld-Str. 21, D-24105, Germany.
| |
Collapse
|
4
|
Lindholm C, Pekkarinen A, Sipilä O, Manninen AL, Lehtinen M, Siiskonen T. ESTIMATION OF HP(3) AMONG STAFF MEMBERS IN TWO NUCLEAR MEDICINE UNITS IN FINLAND. Radiat Prot Dosimetry 2020; 190:176-184. [PMID: 32662509 PMCID: PMC7455372 DOI: 10.1093/rpd/ncaa096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 05/25/2020] [Accepted: 06/10/2020] [Indexed: 06/11/2023]
Abstract
The eye lens exposure among 16 technicians in two nuclear medicine departments at university hospitals in Finland was investigated by measuring the operational quantity Hp(3) using EYE-D dosemeters. For all workers, the annual mean Hp(3) was estimated to be 1.1 mSv (max. 3.9 mSv). The relation between Hp(3) to routinely monitored personal dose equivalent Hp(10) was clearly correlated. Considering individual dose measurement periods (2-4 weeks), the Hp(3)/Hp(10) ratio was 0.7 (Pearson's coefficient r = 0.90, p < 0.001, variation of ratio 0.1-2.3). The variation decreased considerably with increasing Hp(10) (σ2 = 0.04 vs. 0.43 for Hp(10) > 0.1 mSv vs. < 0.1 mSv, respectively), i.e. higher Hp(10) predicts Hp(3) more reliably. Moreover, annual Hp(10) data from national dose register during 2009-2018 were used to derive the annual Hp(3) applying the Hp(3)/Hp(10) ratio. The data from Finnish nuclear medicine departments imply that routine measurements of Hp(3) among nuclear medicine technicians are not justified.
Collapse
Affiliation(s)
- C Lindholm
- STUK-Radiation and Nuclear Safety Authority, POB 14, Helsinki 00811, Finland
| | - A Pekkarinen
- STUK-Radiation and Nuclear Safety Authority, POB 14, Helsinki 00811, Finland
- HUS Medical Imaging Center, Helsinki University Hospital, Helsinki, Finland
- Department of Physics, University of Helsinki, Helsinki, Finland
| | - O Sipilä
- HUS Medical Imaging Center, Clinical Physiology and Nuclear Medicine, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - A-L Manninen
- OYS Department of Nuclear Medicine and Radiology, Oulu University Hospital, Oulu, Finland
- Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - M Lehtinen
- STUK-Radiation and Nuclear Safety Authority, POB 14, Helsinki 00811, Finland
| | - T Siiskonen
- STUK-Radiation and Nuclear Safety Authority, POB 14, Helsinki 00811, Finland
| |
Collapse
|
5
|
Lecchi M, Malaspina S, Del Sole A. Effective and equivalent dose minimization for personnel in PET procedures: how far are we from the goal? Eur J Nucl Med Mol Imaging 2016; 43:2279-2282. [DOI: 10.1007/s00259-016-3513-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
6
|
Guiu-Souto J, Sánchez-García M, Vázquez-Vázquez R, Otero C, Luna V, Mosquera J, Busto RL, Aguiar P, Ruibal Á, Pardo-Montero J, Pombar-Cameán M. Evaluation and optimization of occupational eye lens dosimetry during positron emission tomography (PET) procedures. J Radiol Prot 2016; 36:299-308. [PMID: 27182832 DOI: 10.1088/0952-4746/36/2/299] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The last recommendations of the International Commission on Radiological Protection for eye lens dose suggest an important reduction on the radiation limits associated with early and late tissue reactions. The aim of this work is to quantify and optimize the eye lens dose associated to nurse staff during positron emission tomography (PET) procedures. PET is one of the most important diagnostic methods of oncological and neurological cancer disease involving an important number of workers exposed to the high energy isotope F-18. We characterize the relevant stages as preparation and administration of monodose syringes in terms of occupational dose. A direct reading silicon dosimeter was used to measure the lens dose to staff. The highest dose of radiation was observed during preparation of the fluorodesoxyglucose (FDG) syringes. By optimizing a suitable vials' distribution of FDG we find an important reduction in occupational doses. Extrapolation of our data to other clinical scenarios indicates that, depending on the work load and/or syringes activity, safety limits of the dose might be exceeded.
Collapse
Affiliation(s)
- Jacobo Guiu-Souto
- Department of Medical Physics and Radiological Protection, University Hospital of Santiago de Compostela, Santiago de Compostela, Spain
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|