1
|
Liarakos AL, Hasan N, Crabtree TSJ, Leelarathna L, Hammond P, Hussain S, Haq M, Aslam A, Gatdula E, Gibb FW, Lumb A, Bull K, Chinnasamy E, Carrieri G, Williams DM, Choudhary P, Ryder REJ, Wilmot EG. Real-world outcomes of Omnipod DASH system use in people with type 1 diabetes: Evidence from the Association of British Clinical Diabetologists (ABCD) study. Diabetes Res Clin Pract 2024; 209:111597. [PMID: 38417535 DOI: 10.1016/j.diabres.2024.111597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 02/22/2024] [Accepted: 02/24/2024] [Indexed: 03/01/2024]
Abstract
AIMS To evaluate real-world outcomes in people with Type 1 Diabetes (PwT1D) initiated on Omnipod DASH® Insulin Management System. METHODS Anonymized clinical data were submitted to a secure web-based tool within the National Health Service network. Hemoglobin A1c (HbA1c), sensor-derived glucometrics, total daily dose of insulin (TDD), and patient-reported outcome changes between baseline and follow-up were assessed. Individuals were classified to "new-to-pump" (switched from multiple daily injections) and "established-on-pump" (switched from a tethered insulin pump) groups. RESULTS 276 individuals from 11 centers [66.7 % female; 92 % White British; median age 41 years (IQR 20-50); diabetes duration 20 years (IQR 11-31); 49.3 % within "new-to-pump" group] were included. Baseline HbA1c was 8.0 ± 1.3 % (64 ± 14 mmol/mol). At follow-up [3 years (IQR 1.5-3.2)], HbA1c reduced by 0.3 % [(3 mmol/mol); p = 0.002] across the total population, 0.4 % [(5 mmol/mol); p = 0.001] in those "new-to-pump" and remained unchanged in those "established-on-pump". TDD decreased in the "new-to-pump" cohort (baseline:44.9 ± 21.0units vs follow-up:38.1 ± 15.4units, p = 0.002). Of those asked, 141/143 (98.6 %) stated Omnipod DASH had a positive impact on quality of life. CONCLUSIONS Omnipod DASH was associated with improvements in HbA1c in PwT1D "new-to-pump" and maintained previous HbA1c levels in those "established-on-pump". User satisfaction in all groups and TDD reduction in those "new-to-pump" were reported.
Collapse
Affiliation(s)
- Alexandros L Liarakos
- Department of Diabetes and Endocrinology, University Hospitals of Derby and Burton NHS Foundation Trust, Royal Derby Hospital, Derby, UK; School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham, UK
| | - Nebras Hasan
- Department of Diabetes and Endocrinology, University Hospitals of Derby and Burton NHS Foundation Trust, Royal Derby Hospital, Derby, UK
| | - Thomas S J Crabtree
- Department of Diabetes and Endocrinology, University Hospitals of Derby and Burton NHS Foundation Trust, Royal Derby Hospital, Derby, UK; School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham, UK
| | - Lalantha Leelarathna
- Diabetes, Endocrinology and Metabolism Center, Manchester University NHS Foundation Trust, Manchester Royal Infirmary, Manchester, UK
| | - Peter Hammond
- Department of Diabetes and Endocrinology, Harrogate and District NHS Trust, Harrogate, UK
| | - Sufyan Hussain
- Department of Diabetes and Endocrinology, Guy's and St. Thomas' NHS Foundation Trust, London, UK; Department of Diabetes, School of Cardiovascular, Metabolic Medicine and Sciences, King's College London, London, UK
| | - Masud Haq
- Maidstone & Tunbridge Wells NHS Trust, Tunbridge Wells Hospital, Royal Tunbridge Wells, UK
| | - Aisha Aslam
- Diabetes, Endocrinology and Metabolism Center, Manchester University NHS Foundation Trust, Manchester Royal Infirmary, Manchester, UK
| | - Erneda Gatdula
- Cardiff and Vale University Health Board, University Hospital of Llandough, Llandough, UK
| | - Fraser W Gibb
- Edinburgh Centre for Endocrinology & Diabetes, Royal Infirmary of Edinburgh, Edinburgh, UK; University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | - Alistair Lumb
- Oxford Centre for Diabetes, Endocrinology and Metabolism, Churchill Hospital, Oxford, UK; NIHR Oxford Biomedical Research Centre, Oxford, UK
| | - Kirsty Bull
- Stockport Foundation Trust, Stepping Hill Hospital, Stockport, UK
| | - Eswari Chinnasamy
- Kingston Hospital NHS Foundation Trust, Kingston Hospital, Surrey, UK
| | - Giorgio Carrieri
- Somerset NHS Foundation Trust, Musgrove Park Hospital, Taunton, UK
| | - David M Williams
- Swansea Bay University Health Board, Morriston Hospital, Swansea, UK
| | - Pratik Choudhary
- Leicester Diabetes Center, University Hospitals of Leicester, Leicester, UK; Diabetes Research Center, College of Health Sciences, University of Leicester, Leicester, UK
| | - Robert E J Ryder
- Department of Diabetes and Endocrinology, City Hospital, Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, UK
| | - Emma G Wilmot
- Department of Diabetes and Endocrinology, University Hospitals of Derby and Burton NHS Foundation Trust, Royal Derby Hospital, Derby, UK; School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham, UK.
| |
Collapse
|
2
|
Aleppo G, DeSalvo DJ, Lauand F, Huyett LM, Chang A, Vienneau T, Ly TT. Improvements in Glycemic Outcomes in 4738 Children, Adolescents, and Adults with Type 1 Diabetes Initiating a Tubeless Insulin Management System. Diabetes Ther 2023; 14:593-610. [PMID: 36763329 PMCID: PMC9913031 DOI: 10.1007/s13300-023-01366-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 01/09/2023] [Indexed: 02/11/2023] Open
Abstract
INTRODUCTION Despite recent advances in diabetes technology, most people living with type 1 diabetes mellitus (T1D) are unable to meet glycemic targets. Real-world evidence can provide insight into outcomes achieved with specific treatment devices when used in clinical practice. The aim of this study was to analyze real-world outcomes collected from a large cohort of people living with T1D and initiating treatment with the Omnipod DASH System. METHODS In this retrospective observational study, real-world outcomes were analyzed from a database of information collected from people with T1D initiating the Omnipod DASH System. Information in the database was either taken directly from the patient's medical record or self-reported if medical records were unavailable. The primary outcome was change in glycated hemoglobin (HbA1c) from baseline (before initiation) to 3 months after initiation. Secondary outcomes were changes in total daily dose of insulin (TDD) and self-reported frequency of hypoglycemic events (< 70 mg/dL). Results are separated for the adult (≥ 18 years, N = 3341) and pediatric (< 18 years, N = 1397) cohorts. RESULTS The change in HbA1c from baseline was - 0.9 ± 1.6% ( - 10 ± 18 mmol/mol; p < 0.0001) in adults and - 0.9 ± 2.0% ( - 10 ± 22 mmol/mol; p < 0.0001) in the pediatric cohort. For those previously using multiple daily injections, HbA1c decreased by - 1.0 ± 1.7% ( - 11 ± 19 mmol/mol) in adults and - 1.0 ± 2.1% ( - 11 ± 23 mmol/mol) in the pediatric cohort (both p < 0.0001). Hypoglycemic events decreased in adults from 2.9 to 1.3 episodes per week ( - 1.6 ± 3.2 events/week; p < 0.0001), and in the pediatric cohort from 2.8 to 1.5 episodes per week ( - 1.3 ± 2.7 events/week; p < 0.0001). In adults, TDD decreased by 19.9% (p < 0.0001), and it remained stable in the pediatric cohort (p > 0.05). CONCLUSIONS Real-world outcomes from this large cohort of people initiating therapy with the Omnipod DASH System showed significant improvement in HbA1c and a substantial reduction in hypoglycemic events after 3 months of use.
Collapse
Affiliation(s)
- Grazia Aleppo
- Division of Endocrinology, Metabolism and Molecular Medicine, Feinberg School of Medicine, Northwestern University, 645 North Michigan Ave, Suite 530, Chicago, IL, 60611, USA
| | - Daniel J DeSalvo
- Baylor College of Medicine, 1 Moursund St., Houston, TX, 77030, USA
| | - Felipe Lauand
- Insulet Corporation, 100 Nagog Park, Acton, MA, 01720, USA
| | | | - Albert Chang
- Insulet Corporation, 100 Nagog Park, Acton, MA, 01720, USA
| | - Todd Vienneau
- Insulet Corporation, 100 Nagog Park, Acton, MA, 01720, USA
| | - Trang T Ly
- Insulet Corporation, 100 Nagog Park, Acton, MA, 01720, USA
| |
Collapse
|
3
|
Domingo-Lopez DA, Lattanzi G, H. J. Schreiber L, Wallace EJ, Wylie R, O'Sullivan J, Dolan EB, Duffy GP. Medical devices, smart drug delivery, wearables and technology for the treatment of Diabetes Mellitus. Adv Drug Deliv Rev 2022; 185:114280. [PMID: 35405298 DOI: 10.1016/j.addr.2022.114280] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 02/21/2022] [Accepted: 04/05/2022] [Indexed: 12/13/2022]
Abstract
Diabetes mellitus refers to a group of metabolic disorders which affect how the body uses glucose impacting approximately 9% of the population worldwide. This review covers the most recent technological advances envisioned to control and/or reverse Type 1 diabetes mellitus (T1DM), many of which will also prove effective in treating the other forms of diabetes mellitus. Current standard therapy for T1DM involves multiple daily glucose measurements and insulin injections. Advances in glucose monitors, hormone delivery systems, and control algorithms generate more autonomous and personalised treatments through hybrid and fully automated closed-loop systems, which significantly reduce hypo- and hyperglycaemic episodes and their subsequent complications. Bi-hormonal systems that co-deliver glucagon or amylin with insulin aim to reduce hypoglycaemic events or increase time spent in target glycaemic range, respectively. Stimuli responsive materials for the controlled delivery of insulin or glucagon are a promising alternative to glucose monitors and insulin pumps. By their self-regulated mechanism, these "smart" drugs modulate their potency, pharmacokinetics and dosing depending on patients' glucose levels. Islet transplantation is a potential cure for T1DM as it restores endogenous insulin and glucagon production, but its use is not yet widespread due to limited islet sources and risks of chronic immunosuppression. New encapsulation strategies that promote angiogenesis and oxygen delivery while protecting islets from recipients' immune response may overcome current limiting factors.
Collapse
|
4
|
Eichenlaub M, Ziegler R, Heinemann L, Waldenmaier D, Kamecke U, Haug C, Freckmann G. Patch Pumps: Periodic Insulin Delivery Patterns. J Diabetes Sci Technol 2022:19322968221091843. [PMID: 35466704 DOI: 10.1177/19322968221091843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Recent in vitro experiments with patch pumps (PP) Omnipod (OP), Omnipod DASH (OP-D), A6 TouchCare (A6), and Accu-Chek Solo (ACS) have observed periodic fluctuations in the delivered amount of insulin during basal rate and consecutive bolus delivery in some PP, calling for a more systematic characterization of these periodic delivery patterns. Here, it was found that during basal rate delivery of 1 U/h, some devices of OP, OP-D, and A6 showed deviations of up to ±30% from target delivery that consistently repeated every 5 hours, whereas ACS showed no clear periodicity with considerably lower deviations. Similar results were found during consecutive bolus delivery of 1 U, where deviations repeated consistently every five boluses in some devices of OP, OP-D, and A6. However, there was a large variability in the periodic delivery patterns between individual devices of the same PP model. Examining their pumping techniques indicated a connection between the insulin delivery mechanism and observed delivery patterns of the PP. However, the clinical impact of such patterns is unclear.
Collapse
Affiliation(s)
- Manuel Eichenlaub
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Ralph Ziegler
- Diabetes Clinic for Children and Adolescents, Muenster, Germany
| | | | - Delia Waldenmaier
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | | | - Cornelia Haug
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Guido Freckmann
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| |
Collapse
|
5
|
Biester T, Schwandt A, Heidtmann B, Rami-Merhar B, Haak T, Festa A, Kostow S, Müller A, Mönkemöller K, Danne T. Declining Frequency of Acute Complications Associated with Tubeless Insulin Pump Use: Data from 2,911 Patients in the German/Austrian Diabetes Patienten Verlaufsdokumentation Registry. Diabetes Technol Ther 2021; 23:527-536. [PMID: 33684335 PMCID: PMC8377506 DOI: 10.1089/dia.2020.0675] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Objective: To characterize patients with diabetes treated with a tubeless insulin pump (Omnipod® Insulin Management System; Insulet Corp., Acton, MA), and to evaluate the frequency of acute complications with long-term use of the system. Methods: This retrospective analysis of the German/Austrian Diabetes Patienten Verlaufsdokumentation (DPV) registry included data from 3657 patients with diabetes (n = 3582 type 1, n = 25 type 2, n = 50 latent autoimmune diabetes in adults/other) treated with a tubeless insulin pump. Hemoglobin A1c (HbA1c) levels and frequency of diabetic ketoacidosis (DKA) and severe hypoglycemia (SH) were compared between 1 year pre- and 1 year (n = 2911) or up to 3 years (n = 1311) post-tubeless insulin pump initiation and compared with a contemporary cohort on multiple daily injections (MDI) with 3-year data (n = 1874). Results: Patients using tubeless insulin pump therapy had a median age of 13.7 years [interquartile range 10.8, 17.3], diabetes duration 3.7 years [1.7, 8.0], and HbA1c 7.5% [6.9, 8.2]. In patients with 3 years of follow-up data (n = 1311), the percentage with ≥1 episode of DKA, SH (Level 3, requiring assistance), and SH (coma) event with prior treatment was 6.3%, 5.5%, and 1.7%, respectively. After 3 years of tubeless insulin pump therapy, the frequency of DKA, SH (Level 3), and SH (coma) decreased to 2.2%, 4.1%, and 0.5%, respectively. Both DKA and SH remained significantly lower compared with MDI after adjustment in multiple regression analysis. High treatment retention rates (>90%) were observed. Conclusion: Real-world registry data document that tubeless insulin pump therapy is associated with good glycemic control and a low frequency of DKA and SH in an age group prone to acute complications.
Collapse
Affiliation(s)
- Torben Biester
- AUF DER BULT Diabetes Center for Children and Adolescents, Hannover, Germany
| | - Anke Schwandt
- Institute for Epidemiology and Medical Biometry,ZIBMT,Ulm University, Ulm, Germany
- German Center for Diabetes Research (DZD),Neuherberg, Germany
| | | | - Birgit Rami-Merhar
- Department of Pediatric and Adolescent Medicine,Medical University of Vienna, Vienna, Austria
| | - Thomas Haak
- Diabetes Clinic Bad Mergentheim,Bad Mergentheim,Germany
| | - Andreas Festa
- Landesklinikum Korneuburg Stockerau,Korneuburg Stockerau,Austria
| | - Susanne Kostow
- Sana Klinikum Lichtenberg—Oskar-Ziethen-Krankenhaus,Berlin,Germany
| | | | | | - Thomas Danne
- AUF DER BULT Diabetes Center for Children and Adolescents, Hannover, Germany
- Address correspondence to: Thomas Danne, MD, Diabetes Center for Children and Adolescents, Kinder-und Jugendkrankenhaus AUF DER BULT, Janusz-Korczak-Allee 12, Hannover 30173, Germany
| |
Collapse
|