1
|
Campos I, Gonçalves H, Bernardes J, Castro L. Fetal Heart Rate Preprocessing Techniques: A Scoping Review. Bioengineering (Basel) 2024; 11:368. [PMID: 38671789 DOI: 10.3390/bioengineering11040368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 04/01/2024] [Accepted: 04/06/2024] [Indexed: 04/28/2024] Open
Abstract
Monitoring fetal heart rate (FHR) through cardiotocography is crucial for the early diagnosis of fetal distress situations, necessitating prompt obstetrical intervention. However, FHR signals are often marred by various contaminants, making preprocessing techniques essential for accurate analysis. This scoping review, following PRISMA-ScR guidelines, describes the preprocessing methods in original research articles on human FHR (or beat-to-beat intervals) signal preprocessing from PubMed and Web of Science, published from their inception up to May 2021. From the 322 unique articles identified, 54 were included, from which prevalent preprocessing approaches were identified, primarily focusing on the detection and correction of poor signal quality events. Detection usually entailed analyzing deviations from neighboring samples, whereas correction often relied on interpolation techniques. It was also noted that there is a lack of consensus regarding the definition of missing samples, outliers, and artifacts. Trends indicate a surge in research interest in the decade 2011-2021. This review underscores the need for standardizing FHR signal preprocessing techniques to enhance diagnostic accuracy. Future work should focus on applying and evaluating these methods across FHR databases aiming to assess their effectiveness and propose improvements.
Collapse
Affiliation(s)
- Inês Campos
- Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
- Institute of Biomedical Sciences Abel Salazar, University of Porto, 4050-313 Porto, Portugal
| | - Hernâni Gonçalves
- Center for Health Technology and Services Research (CINTESIS@RISE), Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
- Department of Community Medicine, Information and Health Decision Sciences (MEDCIDS), Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
| | - João Bernardes
- Center for Health Technology and Services Research (CINTESIS@RISE), Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
- Department of Obstetrics and Gynecology, Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
- Department of Obstetrics and Gynecology, São João Hospital, 4200-319 Porto, Portugal
| | - Luísa Castro
- Center for Health Technology and Services Research (CINTESIS@RISE), Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
- Department of Community Medicine, Information and Health Decision Sciences (MEDCIDS), Faculty of Medicine, University of Porto, 4200-319 Porto, Portugal
| |
Collapse
|
2
|
Giordano N, Sbrollini A, Morettini M, Rosati S, Balestra G, Gambi E, Knaflitz M, Burattini L. Acquisition Devices for Fetal Phonocardiography: A Scoping Review. Bioengineering (Basel) 2024; 11:367. [PMID: 38671788 DOI: 10.3390/bioengineering11040367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 03/29/2024] [Accepted: 04/09/2024] [Indexed: 04/28/2024] Open
Abstract
Timely and reliable fetal monitoring is crucial to prevent adverse events during pregnancy and delivery. Fetal phonocardiography, i.e., the recording of fetal heart sounds, is emerging as a novel possibility to monitor fetal health status. Indeed, due to its passive nature and its noninvasiveness, the technique is suitable for long-term monitoring and for telemonitoring applications. Despite the high share of literature focusing on signal processing, no previous work has reviewed the technological hardware solutions devoted to the recording of fetal heart sounds. Thus, the aim of this scoping review is to collect information regarding the acquisition devices for fetal phonocardiography (FPCG), focusing on technical specifications and clinical use. Overall, PRISMA-guidelines-based analysis selected 57 studies that described 26 research prototypes and eight commercial devices for FPCG acquisition. Results of our review study reveal that no commercial devices were designed for fetal-specific purposes, that the latest advances involve the use of multiple microphones and sensors, and that no quantitative validation was usually performed. By highlighting the past and future trends and the most relevant innovations from both a technical and clinical perspective, this review will represent a useful reference for the evaluation of different acquisition devices and for the development of new FPCG-based systems for fetal monitoring.
Collapse
Affiliation(s)
- Noemi Giordano
- Department of Electronics and Telecommunications and PoliToBIOMedLab, Politecnico di Torino, 10129 Torino, Italy
| | - Agnese Sbrollini
- Department of Information Engineering, Engineering Faculty, Università Politecnica delle Marche, 60131 Ancona, Italy
| | - Micaela Morettini
- Department of Information Engineering, Engineering Faculty, Università Politecnica delle Marche, 60131 Ancona, Italy
| | - Samanta Rosati
- Department of Electronics and Telecommunications and PoliToBIOMedLab, Politecnico di Torino, 10129 Torino, Italy
| | - Gabriella Balestra
- Department of Electronics and Telecommunications and PoliToBIOMedLab, Politecnico di Torino, 10129 Torino, Italy
| | - Ennio Gambi
- Department of Information Engineering, Engineering Faculty, Università Politecnica delle Marche, 60131 Ancona, Italy
| | - Marco Knaflitz
- Department of Electronics and Telecommunications and PoliToBIOMedLab, Politecnico di Torino, 10129 Torino, Italy
| | - Laura Burattini
- Department of Information Engineering, Engineering Faculty, Università Politecnica delle Marche, 60131 Ancona, Italy
| |
Collapse
|
3
|
Chen X, Li H, Huang Y, Han W, Yu X, Zhang P, Tao R. Heart sound classification based on equal scale frequency cepstral coefficients and deep learning. BIOMED ENG-BIOMED TE 2023:bmt-2021-0254. [PMID: 36780471 DOI: 10.1515/bmt-2021-0254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 01/17/2023] [Indexed: 02/15/2023]
Abstract
Heart diseases represent a serious medical condition that can be fatal. Therefore, it is critical to investigate the measures of its early prevention. The Mel-scale frequency cepstral coefficients (MFCC) feature has been widely used in the early diagnosis of heart abnormity and achieved promising results. During feature extraction, the Mel-scale triangular overlapping filter set is applied, which makes the frequency response more in line with the human auditory property. However, the frequency of the heart sound signals has no specific relationship with the human auditory system, which may not be suitable for processing of heart sound signals. To overcome this issue and obtain a more objective feature that can better adapt to practical use, in this work, we propose an equal scale frequency cepstral coefficients (EFCC) feature based on replacing the Mel-scale filter set with a set of equally spaced triangular overlapping filters. We further designed classifiers combining convolutional neural network (CNN), recurrent neural network (RNN) and random forest (RF) layers, which can extract both the spatial and temporal information of the input features. We evaluated the proposed algorithm on our database and the PhysioNet Computational Cardiology (CinC) 2016 Challenge Database. Results from ten-fold cross-validation reveal that the EFCC-based features show considerably better performance and robustness than the MFCC-based features on the task of classifying heart sounds from novel patients. Our algorithm can be further used in wearable medical devices to monitor the heart status of patients in real time with high precision, which is of great clinical importance.
Collapse
Affiliation(s)
- Xiaoqing Chen
- College of Information Science and Engineering, Northeastern University, Shenyang, China
| | - Hongru Li
- College of Information Science and Engineering, Northeastern University, Shenyang, China
| | - Youhe Huang
- College of Information Science and Engineering, Northeastern University, Shenyang, China
| | - Weiwei Han
- Shijiazhuang First People's Hospital, Shijiazhuang, China
| | - Xia Yu
- College of Information Science and Engineering, Northeastern University, Shenyang, China
| | - Pengfei Zhang
- Hebei Derui Health Technology Co., Ltd, Shijiazhuang, China
| | - Rui Tao
- College of Information Science and Engineering, Northeastern University, Shenyang, China
| |
Collapse
|
4
|
Barnova K, Kahankova R, Jaros R, Litschmannova M, Martinek R. A comparative study of single-channel signal processing methods in fetal phonocardiography. PLoS One 2022; 17:e0269884. [PMID: 35984866 PMCID: PMC9390939 DOI: 10.1371/journal.pone.0269884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Accepted: 05/29/2022] [Indexed: 11/18/2022] Open
Abstract
Fetal phonocardiography is a non-invasive, completely passive and low-cost method based on sensing acoustic signals from the maternal abdomen. However, different types of interference are sensed along with the desired fetal phonocardiography. This study focuses on the comparison of fetal phonocardiography filtering using eight algorithms: Savitzky-Golay filter, finite impulse response filter, adaptive wavelet transform, maximal overlap discrete wavelet transform, variational mode decomposition, empirical mode decomposition, ensemble empirical mode decomposition, and complete ensemble empirical mode decomposition with adaptive noise. The effectiveness of those methods was tested on four types of interference (maternal sounds, movement artifacts, Gaussian noise, and ambient noise) and eleven combinations of these disturbances. The dataset was created using two synthetic records r01 and r02, where the record r02 was loaded with higher levels of interference than the record r01. The evaluation was performed using the objective parameters such as accuracy of the detection of S1 and S2 sounds, signal-to-noise ratio improvement, and mean error of heart interval measurement. According to all parameters, the best results were achieved using the complete ensemble empirical mode decomposition with adaptive noise method with average values of accuracy = 91.53% in the detection of S1 and accuracy = 68.89% in the detection of S2. The average value of signal-to-noise ratio improvement achieved by complete ensemble empirical mode decomposition with adaptive noise method was 9.75 dB and the average value of the mean error of heart interval measurement was 3.27 ms.
Collapse
Affiliation(s)
- Katerina Barnova
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| | - Radana Kahankova
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| | - Rene Jaros
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
- * E-mail:
| | - Martina Litschmannova
- Department of Applied Mathematics, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| | - Radek Martinek
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
| |
Collapse
|
5
|
Alkhodari M, Widatalla N, Wahbah M, Al Sakaji R, Funamoto K, Krishnan A, Kimura Y, Khandoker AH. Deep learning identifies cardiac coupling between mother and fetus during gestation. Front Cardiovasc Med 2022; 9:926965. [PMID: 35966548 PMCID: PMC9372367 DOI: 10.3389/fcvm.2022.926965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Accepted: 06/29/2022] [Indexed: 11/18/2022] Open
Abstract
In the last two decades, stillbirth has caused around 2 million fetal deaths worldwide. Although current ultrasound tools are reliably used for the assessment of fetal growth during pregnancy, it still raises safety issues on the fetus, requires skilled providers, and has economic concerns in less developed countries. Here, we propose deep coherence, a novel artificial intelligence (AI) approach that relies on 1 min non-invasive electrocardiography (ECG) to explain the association between maternal and fetal heartbeats during pregnancy. We validated the performance of this approach using a trained deep learning tool on a total of 941 one minute maternal-fetal R-peaks segments collected from 172 pregnant women (20–40 weeks). The high accuracy achieved by the tool (90%) in identifying coupling scenarios demonstrated the potential of using AI as a monitoring tool for frequent evaluation of fetal development. The interpretability of deep learning was significant in explaining synchronization mechanisms between the maternal and fetal heartbeats. This study could potentially pave the way toward the integration of automated deep learning tools in clinical practice to provide timely and continuous fetal monitoring while reducing triage, side-effects, and costs associated with current clinical devices.
Collapse
Affiliation(s)
- Mohanad Alkhodari
- Department of Biomedical Engineering, Healthcare Engineering Innovation Center, Khalifa University, Abu Dhabi, United Arab Emirates
- *Correspondence: Mohanad Alkhodari
| | - Namareq Widatalla
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan
| | - Maisam Wahbah
- Department of Biomedical Engineering, Healthcare Engineering Innovation Center, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Raghad Al Sakaji
- Department of Biomedical Engineering, Healthcare Engineering Innovation Center, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Kiyoe Funamoto
- Department of Biomedical Engineering, Healthcare Engineering Innovation Center, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Anita Krishnan
- Division of Cardiology, Children's National Hospital, Washington, DC, United States
| | - Yoshitaka Kimura
- Department of Maternal and Child Health Care Medical Science, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Ahsan H. Khandoker
- Department of Biomedical Engineering, Healthcare Engineering Innovation Center, Khalifa University, Abu Dhabi, United Arab Emirates
- Ahsan H. Khandoker
| |
Collapse
|
6
|
B A, J SK, George S, Arora M. Heart rate estimation and validation algorithm for fetal phonocardiography. Physiol Meas 2022; 43. [PMID: 35724646 DOI: 10.1088/1361-6579/ac7a8c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 06/20/2022] [Indexed: 11/11/2022]
Abstract
Fetal heart rate (FHR) is an important parameter for assessing fetal well-being and is usually measured by doppler ultrasound. Fetal phonocardiography can provide non-invasive, easy-to-use and passive alternative for fetal monitoring method if reliable FHR measurements can be made even in noisy clinical environments. In this work we present an automatic algorithm to determine fetal heart rate from the fetal heart sound recordings in a noisy clinical environment. Using an electronic stethoscope fetal heart sounds were recorded from the expecting mother's abdomen, during weeks 30-40 of their pregnancy. Of these, 60 recordings were analyzed manually by two observers to obtain reference heart rate measurement. An algorithm was developed to determine FHR using envelope detection and autocorrelation of the signals. Algorithm performance was improved by implementing peak validation algorithm utilizing knowledge of valid FHR from prior windows and power spectral density function. The improvements in accuracy and reliability of algorithm were measured by mean absolute error and positive precent agreement. By including the validation step, the mean absolute error reduced from 11.50 to 7.54 beats per minute and positive percent agreement improved from 81% to 87%. The proposed algorithms provide good accuracy overall but are sensitive to the noises in recording environment that influence the quality of the signals.
Collapse
Affiliation(s)
- Amrutha B
- Centre for Product Design and Manufacturing, Indian Institute of Science, CPDM office, CV raman, road,Devasandra Layout,, road,Devasandra Layout,, road,Devasandra Layout,, road,Devasandra Layout,, Bengalurur, Bangalore, 560012, INDIA
| | - Sidhesh Kumar J
- Indian Institute of Science, CPDM office, CV raman, road,Devasandra Layout,, road,Devasandra Layout,, road,Devasandra Layout,, road,Devasandra Layout,, Bengalurur, Bangalore, Karnataka, 560012, INDIA
| | - Shirley George
- St.Johns medical college Hospital, St. John's National Academy of Health Sciences, Sarjapur Road, Bangalore, 560034, INDIA
| | - Manish Arora
- Centre for Product Design and Manufacturing, Indian Institute of Science, CPDM office, CV raman, road,Devasandra Layout,, road,Devasandra Layout,, road,Devasandra Layout,, road,Devasandra Layout,, Bengalurur, Bangalore, 560012, INDIA
| |
Collapse
|
7
|
Vican I, Kreković G, Jambrošić K. Can empirical mode decomposition improve heartbeat detection in fetal phonocardiography signals? Comput Methods Programs Biomed 2021; 203:106038. [PMID: 33770544 DOI: 10.1016/j.cmpb.2021.106038] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Accepted: 03/01/2021] [Indexed: 06/12/2023]
Abstract
BACKGROUND AND OBJECTIVE A fetal phonocardiography signal can be hard to interpret and classify due to various sources of additive noise in the womb, spanning from fetal movement to maternal heart sounds. Nevertheless, the non-invasive nature of the method makes it potentially suitable for long-term monitoring of fetal health, especially since it can be implemented on ubiquitous devices such as smartphones. We have employed empirical mode decomposition for the extraction of intrinsic mode functions that would enable the utilization of additional characteristics from the signal. METHODS Fetal heart recordings from 7 pregnant women in the 3rd trimester or pregnancy were taken in parallel with a measurement microphone and a portable Doppler device. Signal peaks positions from the Doppler were taken as the locations of S1 heart sounds and subsequently used as classification labels for the microphone signal. After employing a moving window approach for segmentation, more than 7600 observations were stored in the final dataset. The 135 extracted features consisted of typical audio temporal and spectral characteristics, each taken from separate sets of audio signals and intrinsic mode functions. We have used a number of metrics and methods to validate the usability of features, including univariate analysis of feature ranking and importance. Furthermore, we have used machine learning to train a number of classifiers to validate the usability of features based on intrinsic mode functions, taking prediction accuracy as the comparison metric. RESULTS Features extracted from intrinsic mode functions combined with audio features significantly improve accuracy in comparison to using only audio features. The improvements of detection accuracy obtained with a selected set of combined features spanned from 3.8% to even 10.3% based on the employed classifier. CONCLUSIONS We have utilized empirical mode decomposition as a method of extracting features relevant for fetal heartbeat classification. The results show consistent improvements in detection accuracy when these characteristics are added to a set of conventional audio features. This implies substantial benefits of applying empirical mode decomposition and lays the groundwork for future research on fetal heartbeat detection.
Collapse
Affiliation(s)
- Ivan Vican
- University of Zagreb, Faculty of Electrical Engineering and Computing, Unska 3, 10000 Zagreb, Croatia.
| | | | - Kristian Jambrošić
- University of Zagreb, Faculty of Electrical Engineering and Computing, Unska 3, 10000 Zagreb, Croatia
| |
Collapse
|
8
|
Khandoker AH, Al-Angari HM, Marzbanrad F, Kimura Y. Investigating myocardial performance in normal and sick fetuses by abdominal Doppler signal derived indices. Curr Res Physiol 2021; 4:29-38. [PMID: 34746824 PMCID: PMC8562139 DOI: 10.1016/j.crphys.2021.02.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 01/20/2021] [Accepted: 02/01/2021] [Indexed: 12/03/2022] Open
Abstract
INTRODUCTION Fetal myocardial performance indices are applied to assess aspects of systolic and diastolic function in developing fetal heart. The aim of this study was to determine normal values of Tei Index (TI) and modified TI (KI) for systolic and diastolic performance in early (<30 weeks), Mid (30-35 weeks) and late (36-41 weeks) relating to both normal fetuses as well as fetuses carrying a variety of fetal abnormalities, which do not call for precise anatomic imaging. MATERIAL AND METHODS Fetal Electrocardiogram Signals (FES) and Doppler Ultrasound Signal (DUS) were simultaneously documented from 55 normal and 25 abnormal fetuses with a variety of abnormalities including Congenital Heart Diseases (CHDs) and a variety of non-CHDs. The isovolumic contraction time (ICT), isovolumic relaxation time (IRT), ventricular ejection time (VET) and ventricular filling time (VFT) were estimated from continuous DUS signals by a hybrid of Hidden Markov and Support Vector Machine based automated model. The TI and the KI were calculated by using the formula (ICT + IRT)/VET and (ICT + IRT)/VFT respectively. RESULTS The TI was not found to show any significant change from early to late fetuses, nor between normal and abnormal cases. On the other hand, KI was shown to significantly decline in values from early to late normal cases and from normal to abnormal groups. Significant correlation (r = -0.36; p < 0.01) of gestational ages with only KI (not TI) was found in this study. CONCLUSION Modified TI (KI) may be a useful index to monitor the normal development of fetal myocardial function and identify fetuses with a variety of CHD and non-CHD cases.
Collapse
Affiliation(s)
- Ahsan H. Khandoker
- Healthcare Engineering Innovation Center (HEIC), Department of Biomedical Engineering Department, Khalifa University, PO Box 127788, Abu Dhabi, United Arab Emirates
| | - Haitham M. Al-Angari
- Healthcare Engineering Innovation Center (HEIC), Department of Biomedical Engineering Department, Khalifa University, PO Box 127788, Abu Dhabi, United Arab Emirates
| | - Faezeh Marzbanrad
- Department of Electrical and Electronic Engineering, Monash University, 14 Alliance Lane (Building 72), Clayton Victoria, 3800, Australia
| | - Yoshitaka Kimura
- Graduate School of Medicine, Tohoku University, Sendai, Miyagi, 980-8575, Japan
| |
Collapse
|
9
|
Alangari HM, Kimura Y, Khandoker AH. Preliminary Evaluation of Fetal Congenital Heart Defects Changes on Fetal-Maternal Heart Rate Coupling Strength. Annu Int Conf IEEE Eng Med Biol Soc 2019; 2018:251-254. [PMID: 30440385 DOI: 10.1109/embc.2018.8512272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Monitoring fetal heart rate in an important aspect in evaluating fetal well being. Maternal-fetal interaction has shown evolution during fetal maturation. In this work, we studied maternal-fetal heart rate synchronization in early and late gestation fetuses. We also evaluated variations in the synchronization due to congenital heart defect (CHD). Maternal-fetal heart rate synchronization for 22 early gestation (Age < 32 weeks), $late gestation (Age >32 weeks) and 7 CHD fetuses (5 of them with gestational age < 32 weeks). The synchronization ratio between the mother and the fetus was more localized at certain fetus heart rate in the early gestation group while it was spreading over more fetal heart rate for the late group. For example, for maternal primary cycle of 3 beat- to-beat (m=3), the synchronization ratio of 5 fetus beats (n=5) contributed 60±30% of the whole coupling ratios for the early group while it contributed 30°30% for the late group (p< 0.01). On the other hand, the coupling ratio of m:n=3:7 contributed 4±17% of the early group and 13±24% for the late group (p< 0.05). The standard deviation of the phase coherence index $(\lambda_{-\mathrm{S}\mathrm{D}})$ for both the late and the CHD groups were significantly higher than the early group at different values. For example, $\lambda -\mathrm{S}\mathrm{D} was 0.006\pm 0.004$ for the early group while it was 0.009±0.008 for the late group (p< 0.01) and 0.01± 0.002 for the CHD group (p< 0.01) for m=3. The variation between the early and late normal groups might indicate a healthy development of the autonomic nervous system while the higher variation in the CHD group could be a good marker for impairment of the cardiac autonomic activity. Further coupling analysis with more abnormal cases is needed to verify these findings.
Collapse
|
10
|
Khandoker A, Ibrahim E, Oshio S, Kimura Y. Validation of beat by beat fetal heart signals acquired from four-channel fetal phonocardiogram with fetal electrocardiogram in healthy late pregnancy. Sci Rep 2018; 8:13635. [PMID: 30206289 DOI: 10.1038/s41598-018-31898-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Accepted: 08/29/2018] [Indexed: 11/08/2022] Open
Abstract
Fetal heart rate monitoring is an essential obstetric procedure, however, false-positive results cause unnecessary obstetric interventions and healthcare cost. In this study, we propose a low cost and non-invasive fetal phonocardiography based signal system to measure the fetal heart sounds and fetal heart rate. Phonocardiogram (PCG) signals contain acoustic information reflecting the contraction and relaxation of the heart. We have developed a four-channel recording device with four separated piezoelectric sensors harnessed by a cloth sheet to record abdominal phonogram signals. A multi-lag covariance matrix based eigenvalue decomposition technique was used to extract fetal and maternal heart sounds as well as maternal breathing movement. In order to validate the fetal heart sounds extracted by PCG signal processing, 10 minutes' simultaneous recordings of fetal Electrocardiogram (fECG) and abdominal phonogram from 15 pregnant women (27 ± 5-year-old) with fetal gestation ages between 33 and 40 weeks were obtained and processed. Highly significant (p < 0.01) correlation (r = 0.96; N = 270) was found between beat to beat fetal heart rate (FHRECG) from fECG and the same (FHRPCG) from fetal PCG signals. Bland-Altman plot of FHRECG and FHRPCG shows good agreement (<5% difference). We conclude that the proposed beat to beat fetal heart rate measurement system would be useful for monitoring fetal neurological wellbeing as a better alternative to traditional cardiotocogram based antenatal fetal heart rate monitoring.
Collapse
|