Acuña J, Situ-LaCasse E, Yarnish AA, McNinch NL, Adhikari S. Does Size Matter? A Prospective Study on the Feasibility of Using a Handheld Ultrasound Device in Place of a Cart-Based System in the Evaluation of Trauma Patients. J Emerg Med 2024; 66:e483-e491. [PMID: 38429215 DOI: 10.1016/j.jemermed.2023.11.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 11/06/2023] [Accepted: 11/16/2023] [Indexed: 03/03/2024]
Abstract
BACKGROUND As emergency physicians are looking at handheld devices as alternatives to the traditional, cart-based systems, concerns center around whether they are forsaking image quality for a lower price point and whether the handheld can be trusted for medical decision making. OBJECTIVE We aimed to determine the feasibility of using a handheld ultrasound device in place of a cart-based system during the evaluation of trauma patients using the Focused Assessment with Sonography for Trauma (FAST) examination. METHODS This was a prospective study of adult trauma patients who received a FAST examination as part of their evaluation. A FAST examination was performed using a cart-based machine and a handheld device. The results of the examinations were compared with computed tomography imaging. Images obtained from both ultrasound devices were reviewed by an expert for image quality. RESULTS A total of 62 patients were enrolled in the study. The mean (SD) time to perform a FAST examination using the handheld device was 307.3 (65.3) s, which was significantly less (p = 0.002) than the 336.1 (86.8) s with the cart-based machine. There was strong agreement between the examination results of the handheld and cart-based devices and between the handheld and computed tomography. Image quality scores obtained with the handheld device were lower than those from the cart-based system. Most operators and reviewers agreed that the images obtained from the handheld were adequate for medical decision making. CONCLUSIONS Data support that it is feasible to use the handheld ultrasound device for evaluation of the trauma patient in place of the cart-based system.
Collapse
Affiliation(s)
- Josie Acuña
- Department of Emergency Medicine, The University of Arizona, College of Medicine, Tucson, Arizona
| | - Elaine Situ-LaCasse
- Department of Emergency Medicine, The University of Arizona, College of Medicine, Tucson, Arizona
| | - Adrienne A Yarnish
- Department of Emergency Medicine, The University of Arizona, College of Medicine, Tucson, Arizona
| | | | - Srikar Adhikari
- Department of Emergency Medicine, The University of Arizona, College of Medicine, Tucson, Arizona
| |
Collapse
|
2
|
Giangregorio F, Mosconi E, Debellis MG, Palermo E, Provini S, Mendozza M, Ricevuti L, Esposito C. Bedside Clinical Hand-held Ultrasound in an Internal Medicine Department: The "Bed Med-Us" Experience of Codogno and its Clinical Utility in the Management of Diagnosis and Therapy in 1007 Patients. Ultrasound Int Open 2024; 10:a21961599. [PMID: 38304447 PMCID: PMC10829908 DOI: 10.1055/a-2196-1599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Accepted: 10/22/2023] [Indexed: 02/03/2024] Open
Abstract
Purpose Handheld ultrasound (HH-US) answers simple clinical questions in emergencies. We performed conventional US with HH-US at the patient's bedside (BED) during a medical visit (MED) (BED MED-US). The purpose of this prospective study is to estimate BED MED-US reliability, its clinical impact in helping the clinician to formulate correct diagnoses, and its ability to save time and money. Materials and Methods 1007 patients (519 M; age:76.42) were assessed (from March 2021 to November 2022) in one or more districts. Final diagnosis was determined with clinical and reference tests (chest RX/CT, abdominal CT, endoscopy, etc.). Sensitivity, specificity, LR+ and LR-, and corresponding AUROC were evaluated. HH-US diagnoses were classified as: confirmation (HH-US revealed the sonographic signs that confirmed the clinical diagnosis) (CO), exclusion (HH-US excluded the presence of the ultrasound signs of other pathologies, in the clinical differential diagnosis) (EX), etiological (HH-US reaches diagnosis in clinically doubtful cases) (ET), or clinically relevant incidental (HH-US diagnoses that change the patient's process completely) (INC). Results HH-US reliability: true-pos: 752; true-neg: 242; false-pos: 7; false-neg: 6 (sens: 99.1%, spec: 97.6%, LR+: 98.5; LR-: 00.15, AUROC: 0.997); clinical impact: CO-diagnosis: 21%; EX: 25%; ET: 47%; INC: 7%; saved time and money: approximately 35,572 minutes of work and 9324 euros. Conclusion BED MED-US is a reliable clinical imaging system, with an important clinical impact both in diagnosis (etiological in 47%, incidental in 7%) and in the management of personnel resources.
Collapse
|
3
|
Osterwalder J, Polyzogopoulou E, Hoffmann B. Point-of-Care Ultrasound-History, Current and Evolving Clinical Concepts in Emergency Medicine. Medicina (Kaunas) 2023; 59:2179. [PMID: 38138282 PMCID: PMC10744481 DOI: 10.3390/medicina59122179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Revised: 12/10/2023] [Accepted: 12/13/2023] [Indexed: 12/24/2023]
Abstract
Point-of-care ultrasound (PoCUS) has become an indispensable standard in emergency medicine. Emergency medicine ultrasound (EMUS) is the application of bedside PoCUS by the attending emergency physician to assist in the diagnosis and management of many time-sensitive health emergencies. In many ways, using PoCUS is not only the mere application of technology, but also a fusion of already existing examiner skills and technology in the context of a patient encounter. EMUS practice can be defined using distinct anatomy-based applications. The type of applications and their complexity usually depend on local needs and resources, and practice patterns can vary significantly among regions, countries, or even continents. A different approach suggests defining EMUS in categories such as resuscitative, diagnostic, procedural guidance, symptom- or sign-based, and therapeutic. Because EMUS is practiced in a constantly evolving emergency medical setting where no two patient encounters are identical, the concept of EMUS should also be practiced in a fluid, constantly adapting manner driven by the physician treating the patient. Many recent advances in ultrasound technology have received little or no attention from the EMUS community, and several important technical advances and research findings have not been translated into routine clinical practice. The authors believe that four main areas have great potential for the future growth and development of EMUS and are worth integrating: 1. In recent years, many articles have been published on novel ultrasound applications. Only a small percentage has found its way into routine use. We will discuss two important examples: trauma ultrasound that goes beyond e-FAST and EMUS lung ultrasound for suspected pulmonary embolism. 2. The more ultrasound equipment becomes financially affordable; the more ultrasound should be incorporated into the physical examination. This merging and possibly even replacement of aspects of the classical physical exam by technology will likely outperform the isolated use of stethoscope, percussion, and auscultation. 3. The knowledge of pathophysiological processes in acute illness and ultrasound findings should be merged in clinical practice. The translation of this knowledge into practical concepts will allow us to better manage many presentations, such as hypotension or the dyspnea of unclear etiology. 4. Technical innovations such as elastography; CEUS; highly sensitive color Doppler such as M-flow, vector flow, or other novel technology; artificial intelligence; cloud-based POCUS functions; and augmented reality devices such as smart glasses should become standard in emergencies over time.
Collapse
Affiliation(s)
| | - Effie Polyzogopoulou
- Emergency Medicine Department, Attikon University Hospital, 12462 Athens, Greece;
| | - Beatrice Hoffmann
- Department of Emergency Medicine BIDMC, One Deaconess Rd., WCC2, Boston, MA 02215, USA
| |
Collapse
|
4
|
Corroenne R, Chesnais M, Khawand C, Attali I, Boucherie AS, Defrance M, Morgan R, Maurey L, Ville Y, Salomon LJ. Physicians' perceptions of the daily use of a handheld ultrasound device in the labor room. J Gynecol Obstet Hum Reprod 2023; 52:102618. [PMID: 37290728 DOI: 10.1016/j.jogoh.2023.102618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 05/23/2023] [Accepted: 06/05/2023] [Indexed: 06/10/2023]
Abstract
OBJECTIVE The objective of our study was to describe the perception of physicians who use a handheld ultrasound (US) device in an intensive perinatal care unit. METHODS We conducted a prospective observational study in the labor ward of an intensive perinatal care unit between November 2021 and May 2022. Obstetrics & Gynecology residents in rotation in our department during this time were recruited as participants in this study. All the participants were provided with a handheld US device Vscan Air™ (GE Healthcare, Zipf, Austria) to use during their normal days and nights practice in labor ward. At the end of their 6 months rotation, participants completed an anonymous surveys about their perceptions of the handheld US device. The survey included questions about the ease of use in clinical situations, the amount of time of initial diagnosis, performances of the device, feasibility to use, and patient's satisfaction with the use of the device. RESULTS 6 residents in their last year of residency were included. All the participants were satisfied with the device and would like to use it in their future practice. They all agreed that the probe was easy to handle and that the mobile application was easy to use. Image quality was always considered good by the participants and 5/6 of them declared that the handheld US device was always sufficient and did not require any confirmation with a conventional US machine. 5/6 of the participants considered that the handheld US device allowed them to gain time for clinical decision but half of them did not estimate that the use of the handheld US device improved their ability to make a clinical diagnosis. CONCLUSION Our study suggests that the Vscan Air™ is easy to use, with a good quality image and reduces the amount of time to make a clinical diagnosis. Handheld US device could be useful in the daily practice in maternity hospital.
Collapse
Affiliation(s)
- Romain Corroenne
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France; EA fetus 7328 and LUMIERE Platform, University of Paris, Paris, France
| | - Marion Chesnais
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Chelsea Khawand
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Isabelle Attali
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Anne Sophie Boucherie
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Manon Defrance
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Rosemary Morgan
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Louise Maurey
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France
| | - Yves Ville
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France; EA fetus 7328 and LUMIERE Platform, University of Paris, Paris, France
| | - Laurent J Salomon
- Department of Obstetrics, Fetal Medicine and Surgery, Necker Enfants Malades Hospital, Paris, France; EA fetus 7328 and LUMIERE Platform, University of Paris, Paris, France.
| |
Collapse
|
5
|
Karlas T, Blank V, Trenker C, Ignee A, Dietrich CF. [Ultrasound systems for abdominal diagnostics - current methods, clinical applications and new technologies]. Z Gastroenterol 2023; 61:1235-1245. [PMID: 36634681 DOI: 10.1055/a-1993-5356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Abdominal ultrasound is the method of first choice in many clinical situations. Gray scale imaging (B-mode) and conventional Doppler techniques are nowadays complemented by contrast-enhanced ultrasound (CEUS), elastography, fat quantification and further technologies which allow multimodal characterization of organs and tissue structure using panoramic imaging, 3D-techniques and image fusion. The development of small portable devices augments the spectrum for sonographic diagnostics. In this review, we describe the current status of ultrasound technology based on published evidence. In addition, we provide guidance for quality assurance.
Collapse
Affiliation(s)
- Thomas Karlas
- Medizinischen Klinik 2, Bereich Gastroenterologie, Universitätsklinikum Leipzig, Leipzig, Germany
| | - Valentin Blank
- Medizinischen Klinik 2, Bereich Gastroenterologie, Universitätsklinikum Leipzig, Leipzig, Germany
- Klinik für Innere Medizin I (Gastroenterologie, Pneumologie) und Interdisziplinäre Ultraschallabteilung, Universitätsklinikum Halle (Saale), Halle, Germany
| | - Corinna Trenker
- Klinik für Hämatologie, Onkologie und Immunologie, Universitätsklinikum Marburg, Marburg, Germany
| | - André Ignee
- Medizinische Klinik mit Schwerpunkt Gastroenterologie & Rheumatologie, Klinikum Würzburg Mitte gGmbH Standort Juliusspital, Wurzburg, Germany
| | - Christoph F Dietrich
- Allgemeine Innere Medizin (DAIM), Kliniken Hirslanden Beau Site, Salem und Permanence, Bern, Switzerland
| |
Collapse
|
6
|
Schäfer VS, Recker F, Kretschmer E, Putensen C, Ehrentraut SF, Staerk C, Fleckenstein T, Mayr A, Seibel A, Schewe JC, Petzinna SM. Lung Ultrasound in Predicting Outcomes in Patients with COVID-19 Treated with Extracorporeal Membrane Oxygenation. Viruses 2023; 15:1796. [PMID: 37766203 PMCID: PMC10535976 DOI: 10.3390/v15091796] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 08/17/2023] [Accepted: 08/22/2023] [Indexed: 09/29/2023] Open
Abstract
Pulmonary involvement due to SARS-CoV-2 infection can lead to acute respiratory distress syndrome in patients with COVID-19. Consequently, pulmonary imaging is crucial for management of COVID-19. This study aimed to evaluate the prognostic value of lung ultrasound (LUS) with a handheld ultrasound device (HHUD) in patients with COVID-19 treated with extracorporeal membrane oxygenation (ECMO). Therefore, patients underwent LUS with a HHUD every two days until they were either discharged from the intensive care unit or died. The study was conducted at the University Hospital of Bonn's anesthesiological intensive care ward from December 2020 to August 2021. A total of 33 patients (median [IQR]: 56.0 [53-60.5] years) were included. A high LUS score was associated with a decreased P/F ratio (repeated measures correlation [rmcorr]: -0.26; 95% CI: -0.34, -0.15; p < 0.001), increased extravascular lung water, defined as fluid accumulation in the pulmonary interstitium and alveoli (rmcorr: 0.11; 95% CI: 0.01, 0.20; p = 0.030), deteriorated electrolyte status (base excess: rmcorr: 0.14; 95% CI: 0.05, 0.24; p = 0.004; pH: rmcorr: 0.12; 95% CI: 0.03, 0.21; p = 0.001), and decreased pulmonary compliance (rmcorr: -0.10; 95% CI: -0.20, -0.01; p = 0.034). The maximum LUS score was lower in survivors (median difference [md]: -0.35; 95% CI: -0.55, -0.06; p = 0.006). A cutoff value for non-survival was calculated at a LUS score of 2.63. At the time of maximum LUS score, P/F ratio (md: 1.97; 95% CI: 1.12, 2.76; p < 0.001) and pulmonary compliance (md: 18.67; 95% CI: 3.33, 37.15; p = 0.018) were higher in surviving patients. In conclusion, LUS with a HHUD enables continuous evaluation of cardiopulmonary function in COVID-19 patients receiving ECMO support therapy and provides prognostic value in determining the patients' likelihood of survival.
Collapse
Affiliation(s)
- Valentin Sebastian Schäfer
- Department of Internal Medicine III, Oncology, Hematology, Rheumatology and Clinical Immunology, University Hospital of Bonn, 53113 Bonn, Germany; (V.S.S.); (E.K.)
| | - Florian Recker
- Department of Obstetrics and Gynecology, University Hospital of Bonn, 53113 Bonn, Germany;
| | - Edgar Kretschmer
- Department of Internal Medicine III, Oncology, Hematology, Rheumatology and Clinical Immunology, University Hospital of Bonn, 53113 Bonn, Germany; (V.S.S.); (E.K.)
| | - Christian Putensen
- Department of Anaesthesiology and Intensive Care Medicine, University Hospital of Bonn, 53113 Bonn, Germany; (C.P.); (S.F.E.); (J.-C.S.)
| | - Stefan Felix Ehrentraut
- Department of Anaesthesiology and Intensive Care Medicine, University Hospital of Bonn, 53113 Bonn, Germany; (C.P.); (S.F.E.); (J.-C.S.)
| | - Christian Staerk
- Institute for Medical Biometry, Informatics and Epidemiology, Medical Faculty, University of Bonn, 53113 Bonn, Germany; (C.S.); (T.F.); (A.M.)
| | - Tobias Fleckenstein
- Institute for Medical Biometry, Informatics and Epidemiology, Medical Faculty, University of Bonn, 53113 Bonn, Germany; (C.S.); (T.F.); (A.M.)
| | - Andreas Mayr
- Institute for Medical Biometry, Informatics and Epidemiology, Medical Faculty, University of Bonn, 53113 Bonn, Germany; (C.S.); (T.F.); (A.M.)
| | - Armin Seibel
- Department of Intensive Care Medicine, DRK Hospital Kirchen, 57548 Kirchen, Germany;
| | - Jens-Christian Schewe
- Department of Anaesthesiology and Intensive Care Medicine, University Hospital of Bonn, 53113 Bonn, Germany; (C.P.); (S.F.E.); (J.-C.S.)
- Department of Anaesthesiology Intensive Care Medicine and Pain Therapy, University Medical Centre Rostock, 18057 Rostock, Germany
| | - Simon Michael Petzinna
- Department of Internal Medicine III, Oncology, Hematology, Rheumatology and Clinical Immunology, University Hospital of Bonn, 53113 Bonn, Germany; (V.S.S.); (E.K.)
| |
Collapse
|
7
|
Schneider E, Maimon N, Hasidim A, Shnaider A, Migliozzi G, Haviv YS, Halpern D, Abu Ganem B, Fuchs L. Can Dialysis Patients Identify and Diagnose Pulmonary Congestion Using Self-Lung Ultrasound? J Clin Med 2023; 12:jcm12113829. [PMID: 37298024 DOI: 10.3390/jcm12113829] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 05/22/2023] [Accepted: 05/31/2023] [Indexed: 06/12/2023] Open
Abstract
BACKGROUND With the recent developments in automated tools, smaller and cheaper machines for lung ultrasound (LUS) are leading us toward the potential to conduct POCUS tele-guidance for the early detection of pulmonary congestion. This study aims to evaluate the feasibility and accuracy of a self-lung ultrasound study conducted by hemodialysis (HD) patients to detect pulmonary congestion, with and without artificial intelligence (AI)-based automatic tools. METHODS This prospective pilot study was conducted between November 2020 and September 2021. Nineteen chronic HD patients were enrolled in the Soroka University Medical Center (SUMC) Dialysis Clinic. First, we examined the patient's ability to obtain a self-lung US. Then, we used interrater reliability (IRR) to compare the self-detection results reported by the patients to the observation of POCUS experts and an ultrasound (US) machine with an AI-based automatic B-line counting tool. All the videos were reviewed by a specialist blinded to the performer. We examined their agreement degree using the weighted Cohen's kappa (Kw) index. RESULTS A total of 19 patients were included in our analysis. We found moderate to substantial agreement between the POCUS expert review and the automatic counting both when the patient performed the LUS (Kw = 0.49 [95% CI: 0.05-0.93]) and when the researcher performed it (Kw = 0.67 [95% CI: 0.67-0.67]). Patients were able to place the probe in the correct position and present a lung image well even weeks from the teaching session, but did not show good abilities in correctly saving or counting B-lines compared to an expert or an automatic counting tool. CONCLUSIONS Our results suggest that LUS self-monitoring for pulmonary congestion can be a reliable option if the patient's count is combined with an AI application for the B-line count. This study provides insight into the possibility of utilizing home US devices to detect pulmonary congestion, enabling patients to have a more active role in their health care.
Collapse
Affiliation(s)
- Eyal Schneider
- Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva 7747629, Israel
| | - Netta Maimon
- Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva 7747629, Israel
| | - Ariel Hasidim
- Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva 7747629, Israel
| | - Alla Shnaider
- Department of Nephrology, Soroka University Medical Center, Beer-Sheva 8457108, Israel
| | - Gabrielle Migliozzi
- Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva 7747629, Israel
| | - Yosef S Haviv
- Department of Nephrology, Soroka University Medical Center, Beer-Sheva 8457108, Israel
| | - Dor Halpern
- Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva 7747629, Israel
| | - Basel Abu Ganem
- Department of Health Policy and Management, Ben-Gurion University of the Negev, Beer-Sheva 7747629, Israel
- Emergency Room, Joseftal Hospital, Eilat 8808024, Israel
| | - Lior Fuchs
- Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva 7747629, Israel
- Medical Intensive Care Unit and Clinical Research Center, Soroka University Medical Center, Beer-Sheva 8457108, Israel
| |
Collapse
|
8
|
Demi M, Soldati G. Lung Ultrasound: A Leading Diagnostic Tool. Diagnostics (Basel) 2023; 13:diagnostics13101710. [PMID: 37238195 DOI: 10.3390/diagnostics13101710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 05/08/2023] [Indexed: 05/28/2023] Open
Abstract
Thoracic ultrasound is an important diagnostic tool employed by many clinicians in well-defined applications [...].
Collapse
Affiliation(s)
- Marcello Demi
- Department of Bioengineering, Fondazione Toscana Gabriele Monasterio, 56126 Pisa, Italy
| | - Gino Soldati
- Diagnostic and Interventional Ultrasound Unit, Ippocrate Medical Center, 55032 Lucca, Italy
| |
Collapse
|
9
|
Le MPT, Voigt L, Nathanson R, Maw AM, Johnson G, Dancel R, Mathews B, Moreira A, Sauthoff H, Gelabert C, Kurian LM, Dumovich J, Proud KC, Solis-McCarthy J, Candotti C, Dayton C, Arena A, Boesch B, Flores S, Foster MT, Villalobos N, Wong T, Ortiz-Jaimes G, Mader M, Sisson C, Soni NJ. Comparison of four handheld point-of-care ultrasound devices by expert users. Ultrasound J 2022; 14:27. [PMID: 35796842 PMCID: PMC9263020 DOI: 10.1186/s13089-022-00274-6] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 05/16/2022] [Indexed: 11/30/2022] Open
Abstract
Background Point-of-care ultrasound (POCUS) is rapidly becoming ubiquitous across healthcare specialties. This is due to several factors including its portability, immediacy of results to guide clinical decision-making, and lack of radiation exposure to patients. The recent growth of handheld ultrasound devices has improved access to ultrasound for many clinicians. Few studies have directly compared different handheld ultrasound devices among themselves or to cart-based ultrasound machines. We conducted a prospective observational study comparing four common handheld ultrasound devices for ease of use, image quality, and overall satisfaction. Twenty-four POCUS experts utilized four handheld devices (Butterfly iQ+™ by Butterfly Network Inc., Kosmos™ by EchoNous, Vscan Air™ by General Electric, and Lumify™ by Philips Healthcare) to obtain three ultrasound views on the same standardized patients using high- and low-frequency probes. Results Data were collected from 24 POCUS experts using all 4 handheld devices. No single ultrasound device was superior in all categories. For overall ease of use, the Vscan Air™ was rated highest, followed by the Lumify™. For overall image quality, Lumify™ was rated highest, followed by Kosmos™. The Lumify™ device was rated highest for overall satisfaction, while the Vscan Air™ was rated as the most likely to be purchased personally and carried in one’s coat pocket. The top 5 characteristics of handheld ultrasound devices rated as being “very important” were image quality, ease of use, portability, total costs, and availability of different probes. Conclusions In a comparison of four common handheld ultrasound devices in the United States, no single handheld ultrasound device was perceived to have all desired characteristics. POCUS experts rated the Lumify™ highest for image quality and Vscan Air™ highest for ease of use. Overall satisfaction was highest with the Lumify™ device, while the most likely to be purchased as a pocket device was the Vscan Air™. Image quality was felt to be the most important characteristic in evaluating handheld ultrasound devices. Supplementary Information The online version contains supplementary material available at 10.1186/s13089-022-00274-6.
Collapse
|
10
|
Stoicescu ER, Manolescu DL, Iacob R, Cerbu S, Dima M, Iacob ER, Ciuca IM, Oancea C, Iacob D. The Assessment of COVID-19 Pneumonia in Neonates: Observed by Lung Ultrasound Technique and Correlated with Biomarkers and Symptoms. J Clin Med 2022; 11:3555. [PMID: 35743621 DOI: 10.3390/jcm11123555] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 06/18/2022] [Accepted: 06/19/2022] [Indexed: 02/01/2023] Open
Abstract
Newborns infected with SARS-CoV2 infection develop different symptoms in comparison with adults, but one thing is clear: some of the most common manifestations include cough and other respiratory symptoms that need to be evaluated. In these cases, lung ultrasound is a useful imaging technique that can evaluate the newborns’ lung damage caused by COVID-19 pneumonia and can be used for the surveillance of the patients as well, being non-irradiating and easy to use. Nineteen neonates who were confirmed as having SARS-CoV2 infection were investigated using this imaging tool, and the results were compared and correlated with their symptoms and biomarkers. The mean of LUSS was 12.21 ± 3.56 (S.D), while the 95% CI for the arithmetic mean was 10.49–13.93. The difference of an independent t-test between the LUSS for the patient who presented cough and the LUSS for the patient without cough was −4.48 with an associated p-value of p = 0.02. The Pearson’s correlation coefficient r = 0.89 (p = 0.03, 95% CI 0.0642 to 0.993) between the LUSS and IL-6 level showed a positive strong correlation. This reliable correlation between lung ultrasound score and inflammatory markers suggests that LUS could be used for monitoring inflammatory lung diseases in the future.
Collapse
|
11
|
Dadon Z, Levi N, Alpert EA, Orlev A, Belman D, Glikson M, Butnaru A, Gottlieb S. The quality, safety, feasibility, and interpretive accuracy of echocardiographic and lung ultrasound assessment of COVID-19 patients using a hand-held ultrasound. Echocardiography 2022; 39:886-894. [PMID: 35668047 PMCID: PMC9348495 DOI: 10.1111/echo.15372] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 05/01/2022] [Accepted: 05/13/2022] [Indexed: 11/27/2022] Open
Abstract
Background The association between COVID‐19 infection and the cardiovascular system necessitates the use of an echocardiogram in this setting. Information on the utilization, safety, and quality of point‐of‐care cardiac and lung ultrasound using a hand‐held device in these patients is scarce. Aims To investigate the safety, technical aspects, quality indices, and interpretive accuracy of a hand‐held echocardiogram in patients with COVID‐19. Methods From April‐28 through July‐27, 2020, consecutive patients with COVID‐19 underwent hand‐held echocardiogram and lung ultrasound evaluation (Vscan Extend™; GE Healthcare) within 48‐h of admission. The operators recorded a series of technical parameters and graded individual experiences. The examinations were further analyzed by a blinded fellowship‐trained echocardiographer for general quality, proper acquisition, and right ventricular (RV) demonstration. Results Among 103 patients, 66 (64.1%) were male. Twenty‐nine (28.2%) patients could not turn on their left side and 23 (22.3%) could not maintain effective communication. The mean length of each echocardiogram study was 8.5 ± 2.9 min, battery usage was 14 ± 5%, and mean operator‐to‐patient proximity was 59 ± 11 cm. Ninety‐five (92.2%) examinations were graded as fair/good quality. A fair agreement was demonstrated between the operator and the echocardiographer for general ultrasound quality (Kappa = 0.329, p < 0.001). A fair‐good correlation (r = 0.679, p < 0.001) and substantial agreement (Kappa = 0.612, p < 0.001) were demonstrated between the operator and echocardiographer for left ventricular ejection fraction (LVEF), whereas a fair agreement was demonstrated for RV systolic function (Kappa = 0.308, p = 0.002). LVEF agreement was also assessed using the Bland‐Altman analysis revealing a mean bias of −0.96 (95% limits of agreement 9.43 to −11.35; p = 0.075). Conclusions Among patients with COVID‐19, echocardiography with a hand‐held ultrasound is a safe and reasonable alternative for a complete formal study (<10% poor‐quality indices). Echocardiogram assessment by the operators during the exam acquisition is reliable for LVEF, while RV systolic function should be subsequently offline reassessed.
Collapse
Affiliation(s)
- Ziv Dadon
- Jesselson Integrated Heart Center, Shaare Zedek Medical Center, Jerusalem, Israel
| | - Nir Levi
- Jesselson Integrated Heart Center, Shaare Zedek Medical Center, Jerusalem, Israel
| | - Evan Avraham Alpert
- Department of Emergency Medicine, Shaare Zedek Medical Center, Jerusalem, Israel.,Faculty of Medicine, Hebrew University of Jerusalem, Israel
| | - Amir Orlev
- Jesselson Integrated Heart Center, Shaare Zedek Medical Center, Jerusalem, Israel
| | - Daniel Belman
- Intensive Care Unit, Shaare Zedek Medical Center, Jerusalem, Israel
| | - Michael Glikson
- Jesselson Integrated Heart Center, Shaare Zedek Medical Center, Jerusalem, Israel.,Faculty of Medicine, Hebrew University of Jerusalem, Israel
| | - Adi Butnaru
- Jesselson Integrated Heart Center, Shaare Zedek Medical Center, Jerusalem, Israel
| | - Shmuel Gottlieb
- Jesselson Integrated Heart Center, Shaare Zedek Medical Center, Jerusalem, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
12
|
Ibarra-Ríos D, Enríquez-Estrada AC, Serpa-Maldonado EV, Miranda-Vega AL, Villanueva-García D, Vázquez-Solano EP, Márquez-González H. Lung Ultrasound Characteristics in Neonates With Positive Real Time Polymerase Chain Reaction for SARS-CoV-2 on a Tertiary Level Referral Hospital in Mexico City. Front Pediatr 2022; 10:859092. [PMID: 35463891 PMCID: PMC9033263 DOI: 10.3389/fped.2022.859092] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 02/24/2022] [Indexed: 11/29/2022] Open
Abstract
INTRODUCTION Acute respiratory syndrome secondary to SARS-CoV-2 virus infection has been declared a pandemic since December 2019. On neonates, severe presentations are infrequent but possible. Lung ultrasound (LUS) has been shown to be useful in diagnosing lung involvement and following up patients, giving more information, and reducing exposure compared to traditional examination. METHODS LUS was performed after the diagnosis of SARS-CoV-2 infection with respiratory Real Time Polymerase Chain Reaction RT-PCR with portable equipment protected with a silicone sleeve. If hemodynamic or cardiology consultation was necessary, a prepared complete ultrasound machine was used. Ten regions were explored (anterior superior and inferior, lateral, and posterior superior and inferior, right and left), and a semiquantitative score (LUSS) was calculated. Disease severity was determined with a pediatric modified score. RESULTS Thirty-eight patients with positive RT-PCR were admitted, 32 (81%) of which underwent LUS. Included patients had heterogenous diagnosis and gestational ages as expected on a referral neonatal intensive care unit (NICU) (median, ICR: 36, 30-38). LUS abnormalities found were B-line interstitial pattern 90%, irregular/interrupted/thick pleural line 88%, compact B-lines 65%, small consolidations (≤5 mm) 34%, and extensive consolidations (≥5 mm) 37%. Consolidations showed posterior predominance (70%). LUSS showed a median difference between levels of disease severity and ventilatory support (Kruskal-Wallis, p = 0.001) and decreased with patient improvement (Wilcoxon signed-rank test p = 0.005). There was a positive correlation between LUSS and FiO2 needed (Spearman r = 0.72, p = 0.01). The most common recommendation to the attending team was pronation (41%) and increase in positive end expiratory pressure (34%). Five patients with comorbidities died. A significant rank difference of LUSS and FiO2 needed between survivors and non-survivors was found (Mann-Whitney U-test, p = 0.005). CONCLUSION LUS patterns found were like the ones described in other series (neonatal and pediatrics). Eighty-eight percent of the studies were performed with handheld affordable equipment. While there is no specific pattern, it varies according to gestational age and baseline diagnosis LUS, which were shown to be useful in assessing lung involvement that correlated with the degree of disease severity and respiratory support.
Collapse
Affiliation(s)
- Daniel Ibarra-Ríos
- Neonatology Department, National Institutes of Health, Hospital Infantil de México Federico Gómez, Mexico City, Mexico
| | | | | | - Ana Luisa Miranda-Vega
- Neonatology Department, National Institutes of Health, Hospital Infantil de México Federico Gómez, Mexico City, Mexico
| | - Dina Villanueva-García
- Neonatology Department, National Institutes of Health, Hospital Infantil de México Federico Gómez, Mexico City, Mexico
| | - Edna Patricia Vázquez-Solano
- Neonatology Department, National Institutes of Health, Hospital Infantil de México Federico Gómez, Mexico City, Mexico
| | - Horacio Márquez-González
- Clinical Investigation Department, National Institutes of Health, Hospital Infantil de México Federico Gómez, Mexico City, Mexico
| |
Collapse
|
13
|
Stoicescu ER, Ciuca IM, Iacob R, Iacob ER, Marc MS, Birsasteanu F, Manolescu DL, Iacob D. Is Lung Ultrasound Helpful in COVID-19 Neonates?-A Systematic Review. Diagnostics (Basel) 2021; 11:diagnostics11122296. [PMID: 34943533 PMCID: PMC8699875 DOI: 10.3390/diagnostics11122296] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 12/01/2021] [Accepted: 12/03/2021] [Indexed: 12/23/2022] Open
Abstract
Background: The SARS-CoV-2 infection has occurred in neonates, but it is a fact that radiation exposure is not recommended given their age. The aim of this review is to assess the evidence on the utility of lung ultrasound (LUS) in neonates diagnosed with COVID-19. Methods: A systematic literature review was performed so as to find a number of published studies assessing the benefits of lung ultrasound for newborns diagnosed with COVID and, in the end, to make a comparison between LUS and the other two more conventional procedures of chest X-rays or CT exam. The key terms used in the search of several databases were: “lung ultrasound”, “sonography”, “newborn”, “neonate”, and “COVID-19′. Results: In total, 447 studies were eligible for this review, and after removing the duplicates, 123 studies referring to LU were further examined, but only 7 included cases of neonates. These studies were considered for the present research paper. Conclusions: As a non-invasive, easy-to-use, and reliable method for lung lesion detection in neonates with COVID-19, lung ultrasound can be used as a useful diagnosis tool for the evaluation of COVID-19-associated lung lesions. The benefits of this method in this pandemic period are likely to arouse interest in opening new research horizons, with immediate practical applicability.
Collapse
Affiliation(s)
- Emil Robert Stoicescu
- Department of Radiology and Medical Imaging, ‘Victor Babes’ University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania; (E.R.S.); (R.I.); (F.B.); (D.L.M.)
- Research Center for Pharmaco-Toxicological Evaluations, ‘Victor Babes’ University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania;
| | - Ioana Mihaiela Ciuca
- Pediatric Department, ‘Victor Babes’ University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
- Correspondence:
| | - Roxana Iacob
- Department of Radiology and Medical Imaging, ‘Victor Babes’ University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania; (E.R.S.); (R.I.); (F.B.); (D.L.M.)
| | - Emil Radu Iacob
- Department of Pediatric Surgery, ‘Victor Babes’ University of Medicine and Pharmacy, Eftimie Murgu Square 2, 300041 Timisoara, Romania;
| | - Monica Steluta Marc
- Pulmonology Department, ‘Victor Babes’ University of Medicine and Pharmacy, Eftimie Murgu Square 2, 300041 Timisoara, Romania;
| | - Florica Birsasteanu
- Department of Radiology and Medical Imaging, ‘Victor Babes’ University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania; (E.R.S.); (R.I.); (F.B.); (D.L.M.)
| | - Diana Luminita Manolescu
- Department of Radiology and Medical Imaging, ‘Victor Babes’ University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania; (E.R.S.); (R.I.); (F.B.); (D.L.M.)
- Center for Research and Innovation in Precision Medicine of Respiratory Diseases (CRIPMRD), ‘Victor Babeș’ University of Medicine and Pharmacy, 300041 Timișoara, Romania
| | - Daniela Iacob
- Research Center for Pharmaco-Toxicological Evaluations, ‘Victor Babes’ University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania;
- Department of Neonatology, ‘Victor Babes’ University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| |
Collapse
|