• Reference Citation Analysis
  • v
  • v
  • Find an Article
  • Find an Author
Download
For: Choi S, Park K, Lee S, Lim Y, Oh B, Chae HY, Park CS, Shin H, Kim JJ. A Three-Step Resolution-Reconfigurable Hazardous Multi-Gas Sensor Interface for Wireless Air-Quality Monitoring Applications. Sensors (Basel) 2018;18:s18030761. [PMID: 29498686 PMCID: PMC5876904 DOI: 10.3390/s18030761] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Revised: 02/22/2018] [Accepted: 03/01/2018] [Indexed: 11/28/2022]
Number Cited by Other Article(s)
1
Fadhil MJ, Gharghan SK, Saeed TR. Air pollution forecasting based on wireless communications: review. Environ Monit Assess 2023;195:1152. [PMID: 37670163 DOI: 10.1007/s10661-023-11756-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Accepted: 08/19/2023] [Indexed: 09/07/2023]
2
Chen L, Chang C, Chien L, Lee B, Shieh W. A Novel Packaging of the MEMS Gas Sensors Used for Harsh Outdoor and Human Exhale Sampling Applications. Sensors (Basel) 2023;23:s23115087. [PMID: 37299814 DOI: 10.3390/s23115087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 05/22/2023] [Accepted: 05/24/2023] [Indexed: 06/12/2023]
3
Lee DY, Yu JB, Byun HG, Kim HJ. Chemoresistive Sensor Readout Circuit Design for Detecting Gases with Slow Response Time Characteristics. Sensors (Basel) 2022;22:s22031102. [PMID: 35161847 PMCID: PMC8839109 DOI: 10.3390/s22031102] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 01/20/2022] [Accepted: 01/29/2022] [Indexed: 06/02/2023]
4
Al-Okby MFR, Neubert S, Roddelkopf T, Thurow K. Mobile Detection and Alarming Systems for Hazardous Gases and Volatile Chemicals in Laboratories and Industrial Locations. Sensors (Basel) 2021;21:8128. [PMID: 34884132 PMCID: PMC8662412 DOI: 10.3390/s21238128] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 11/30/2021] [Accepted: 12/01/2021] [Indexed: 11/16/2022]
5
Yang TS, Chiou JC. A High-Efficiency Driver Circuit for a Gas-Sensor Microheater Based on a Switch-Mode DC-to-DC Converter. Sensors (Basel) 2020;20:E5367. [PMID: 32961704 DOI: 10.3390/s20185367] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 09/14/2020] [Accepted: 09/16/2020] [Indexed: 02/03/2023]
6
Fahim F, Bianconi S, Rabinowitz J, Joshi S, Mohseni H. Dynamically Reconfigurable Data Readout of Pixel Detectors for Automatic Synchronization with Data Acquisition Systems. Sensors (Basel) 2020;20:E2560. [PMID: 32365939 DOI: 10.3390/s20092560] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Revised: 04/12/2020] [Accepted: 04/21/2020] [Indexed: 11/29/2022]
7
Lee K, Chae HY, Park K, Lee Y, Cho S, Ko H, Kim JJ. A Multi-Functional Physiological Hybrid-Sensing E-Skin Integrated Interface for Wearable IoT Applications. IEEE Trans Biomed Circuits Syst 2019;13:1535-1544. [PMID: 31613778 DOI: 10.1109/tbcas.2019.2946875] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA