1
|
Abstract
Lead is a naturally occurring, bluish-gray metal that is found in small quantities in the earth's crust. The existing literature demonstrates that non-biodegradable character and continuous use results in accumulation of lead concentration in the environment and causes various ill effects such as neurotoxicity, change in psychological and behavioral development of different organisms. Nowadays the most effective technique in the revival of the environment is bioremediation and it is environmentally friendly and cost-effective. Bacterial strains such as Oceanobacillus profundus and Lactobacillus acidophilus ATCC4356 have the ability to reduce lead 97% and 73.9%, respectively. Similarly some species of algae and fungal strains also showed lead removal efficiency as 74% (spirulina), 97.1% (Chlorella kessleri), 95.5% (Penicillium janthinillum) and 86% (Aspergillus flavus). Biodegradation of lead by various microbes would be the most efficient and sustainable approach. This review focuses on toxicity, fate of lead in the environment and its microbial degradation.
Collapse
Affiliation(s)
- Khushhal Kumar
- Department of Zoology, Central University of Jammu, Rahya-Suchani, Samba, Jammu and Kashmir, India
| | - Devinder Singh
- Department of Zoology, Chandigarh University, Mohali, Punjab, India
| |
Collapse
|
2
|
Lai WQ, Chang YF, Chou FN, Yang DM. Portable FRET-Based Biosensor Device for On-Site Lead Detection. Biosensors (Basel) 2022; 12:bios12030157. [PMID: 35323427 PMCID: PMC8946079 DOI: 10.3390/bios12030157] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 02/24/2022] [Accepted: 02/28/2022] [Indexed: 05/31/2023]
Abstract
Most methods for measuring environmental lead (Pb) content are time consuming, expensive, hazardous, and restricted to specific analytical systems. To provide a facile, safe tool to detect Pb, we created pMet-lead, a portable fluorescence resonance energy transfer (FRET)-based Pb-biosensor. The pMet-lead device comprises a 3D-printed frame housing a 405-nm laser diode-an excitation source for fluorescence emission images (YFP and CFP)-accompanied by optical filters, a customized sample holder with a Met-lead 1.44 M1 (the most recent version)-embedded biochip, and an optical lens aligned for smartphone compatibility. Measuring the emission ratios (Y/C) of the FRET components enabled Pb detection with a dynamic range of nearly 2 (1.96), a pMet-lead/Pb dissociation constant (Kd) 45.62 nM, and a limit of detection 24 nM (0.474 μg/dL, 4.74 ppb). To mitigate earlier problems with a lack of selectivity for Pb vs. zinc, we preincubated samples with tricine, a low-affinity zinc chelator. We validated the pMet-lead measurements of the characterized laboratory samples and unknown samples from six regions in Taiwan by inductively coupled plasma mass spectrometry (ICP-MS). Notably, two unknown samples had Y/C ratios significantly higher than that of the control (3.48 ± 0.08 and 3.74 ± 0.12 vs. 2.79 ± 0.02), along with Pb concentrations (10.6 ppb and 15.24 ppb) above the WHO-permitted level of 10 ppb in tap water, while the remaining four unknowns showed no detectable Pb upon ICP-MS. These results demonstrate that pMet-lead provides a rapid, sensitive means for on-site Pb detection in water from the environment and in living/drinking supply systems to prevent potential Pb poisoning.
Collapse
Affiliation(s)
- Wei-Qun Lai
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei 11217, Taiwan; (W.-Q.L.); (F.-N.C.)
- Institute of Biophotonics, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan
| | - Yu-Fen Chang
- LumiSTAR Biotechnology, Inc., Taipei City 115, Taiwan;
| | - Fang-Ning Chou
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei 11217, Taiwan; (W.-Q.L.); (F.-N.C.)
| | - De-Ming Yang
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei 11217, Taiwan; (W.-Q.L.); (F.-N.C.)
- Institute of Biophotonics, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan
| |
Collapse
|
3
|
Yang DM, Chang YF. Versatile Cell and Animal Models for Advanced Investigation of Lead Poisoning. Biosensors (Basel) 2021; 11:371. [PMID: 34677327 DOI: 10.3390/bios11100371] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 10/01/2021] [Accepted: 10/02/2021] [Indexed: 12/30/2022]
Abstract
The heavy metal, lead (Pb) can irreversibly damage the human nervous system. To help understand Pb-induced damage, we applied a genetically encoded Förster resonance energy transfer (FRET)-based Pb biosensor Met-lead 1.44 M1 to two living systems to monitor the concentration of Pb: induced pluripotent stem cell (iPSC)-derived cardiomyocytes as a semi-tissue platform and Drosophila melanogaster fruit flies as an in vivo animal model. Different FRET imaging modalities were used to obtain FRET signals, which represented the presence of Pb in the tested samples in different spatial dimensions. Using iPSC-derived cardiomyocytes, the relationship between beating activity (20–24 beats per minute, bpm) determined from the fluctuation of fluorescent signals and the concentrations of Pb represented by the FRET emission ratio values of Met-lead 1.44 M1 was revealed from simultaneous measurements. Pb (50 μM) affected the beating activity of cardiomyocytes, whereas two drugs that stop the entry of Pb differentially affected this beating activity: verapamil (2 μM) did not reverse the cessation of beating, whereas 2-APB (50 μM) partially restored this activity (16 bpm). The results clearly demonstrate the potential of this biosensor system as an anti-Pb drug screening application. In the Drosophila model, Pb was detected within the adult brain or larval central nervous system (Cha-gal4 > UAS-Met-lead 1.44 M1) using fast epifluorescence and high-resolution two-photon 3D FRET ratio image systems. The tissue-specific expression of Pb biosensors provides an excellent opportunity to explore the possible Pb-specific populations within living organisms. We believe that this integrated Pb biosensor system can be applied to the prevention of Pb poisoning and advanced research on Pb neurotoxicology.
Collapse
|
4
|
Yang DM, Fu TF, Lin CS, Chiu TY, Huang CC, Huang HY, Chung MW, Lin YS, Manurung RV, Nguyen PNN, Chang YF. High-performance FRET biosensors for single-cell and in vivo lead detection. Biosens Bioelectron 2020; 168:112571. [PMID: 32892119 DOI: 10.1016/j.bios.2020.112571] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 08/25/2020] [Accepted: 08/27/2020] [Indexed: 12/31/2022]
Abstract
Forms of lead (Pb) have been insidiously invading human life for thousands of years without obvious signs of their considerable danger to human health. Blood lead level (BLL) is the routine measure used for diagnosing the degree of lead intoxication, although it is unclear whether there is any safe range of BLL. To develop a practical detection tool for living organisms, we engineered a genetically encoded fluorescence resonance energy transfer (FRET)-based Pb2+ biosensor, 'Met-lead 1.44 M1', with excellent performance. Met-lead 1.44 M1 has an apparent dissociation constant (Kd) of 25.97 nM, a detection limit (LOD) of 10 nM (2.0 ppb/0.2 μg/dL), and an enhancement dynamic ratio of nearly ~ 5-fold upon Pb2+ binding. The 10 nM sensitivity of Met-lead 1.44 M1 is five times below the World Health Organization-permitted level of lead in tap water (10 ppb; WHO, 2017), and fifteen times lower than the maximum BLL for children (3 μg/dL). We deployed Met-lead 1.44 M1 to measure Pb2+ concentrations in different living models, including two general human cell lines and one specific line, induced pluripotent stem cell (iPSC)-derived cardiomyocytes, as well as in widely used model species in plant (Arabidopsis thaliana) and animal (Drosophila melanogaster) research. Our results suggest that this new biosensor is suitable for lead toxicological research in vitro and in vivo, and will pave the way toward potential applications for both low BLL measures and rapid detection of environmental lead in its divalent form.
Collapse
Affiliation(s)
- De-Ming Yang
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei, 11217, Taiwan; Institute of Biophotonics, National Yang-Ming University, 155 Sec-2, Li Nong Street, Taipei, 11221, Taiwan; Biophotonics and Molecular Imaging Research Center (BMIRC), National Yang-Ming University, Taipei, 11221, Taiwan.
| | - Tsai-Feng Fu
- Department of Applied Chemistry, National Chi-Nan University, Nantou, 54561, Taiwan
| | - Choun-Sea Lin
- Agricultural Biotechnology Research Center (ABRC), Academia Sinica, Taipei, 115, Taiwan
| | - Tai-Yu Chiu
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei, 11217, Taiwan
| | - Chien-Chang Huang
- Core Facilities for Translational Medicines, BioTReC, Academia Sinica, Taipei, 115, Taiwan
| | - Hsin-Yi Huang
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei, 11217, Taiwan; LumiSTAR Biotechnology, Inc., National Biotechnology Research Park, Taipei, 115, Taiwan
| | - Min-Wen Chung
- LumiSTAR Biotechnology, Inc., National Biotechnology Research Park, Taipei, 115, Taiwan
| | - Yu-Syuan Lin
- Microscopy Service Laboratory, Basic Research Division, Department of Medical Research, Taipei Veterans General Hospital, Taipei, 11217, Taiwan
| | - Robeth Viktoria Manurung
- Research Center for Electronics and Telecommunication, Indonesian Institute of Sciences (LIPI), Indonesia
| | | | - Yu-Fen Chang
- LumiSTAR Biotechnology, Inc., National Biotechnology Research Park, Taipei, 115, Taiwan.
| |
Collapse
|