Ruan X, Yang G, Xia Z, Zhang J, Gu X, Tan Y, Liu Z, Luo L. Agreement of Anterior Segment Parameter Measurements With CASIA 2 and IOLMaster 700. Front Med (Lausanne) 2022; 9:777443. [PMID: 35223893 PMCID: PMC8874008 DOI: 10.3389/fmed.2022.777443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 01/11/2022] [Indexed: 11/13/2022] Open
Abstract
PurposeTo compare the difference and agreement in central corneal thickness (CCT), keratometry (K), anterior chamber depth (ACD), aqueous depth (AQD), and lens thickness (LT) measured with CASIA 2 and IOLMaster 700 in patients with cataract.MethodsA total of 81 patients with cataract (81 eyes) scheduled for phacoemulsification were prospectively collected from March to May, 2020 in the cataract department of Zhongshan Ophthalmic Center, Sun Yat-sen University, including 43 males and 38 females with age of 61.5 ± 10.6 years. CCT, anterior Kf, anterior Ks, real Kf, real Ks, ACD, AQD, and LT were measured with CASIA 2 and IOLMaster 700. Paired t-test, intraclass correlation coefficients (ICCs), 95% limit of agreement (95% LoA), and Bland-Altman plots were performed and used to analyze the difference and agreement between the two devices.ResultsThere was no statistically significant difference in anterior K measurement with the CASIA 2 (44.3 ± 1.66 mm) and IOLMaster 700 (44.31 ± 1.67 mm, P = 0.483). Differences among the CCT, anterior Kf, real Kf, real Ks, ACD, AQD, and LT measured by the two instruments were statistically significant (P < 0.001). The ICCs of CCT, anterior Kf, anterior Ks, real Kf, real Ks, ACD, AQD, and LT measurements between the two devices were 0.892, 0.991, 0.991, 0.827, 0.817, 0.937, 0.926, and 0.997, respectively. The 95% LoA between CASIA 2 and IOLMaster 700 was −30.06 to 0.43 μm for CCT, −0.3 to 0.48 D for anterior Kf, −0.46 to −0.43 D for anterior Ks, −1.49 to −0.49 D for real Kf, −1.62 to −0.49 D for Real Ks, −0.03 to 0.24 mm for ACD, 0.04 to 0.25 mm for AQD, and −0.06 to 0.09 mm for LT.ConclusionAnterior Kf, anterior Ks, ACD, AQD, and LT have excellent agreement between the two devices. CCT, real Kf, and real Ks have moderate agreement between the two devices. It is recommended to use anterior Kf, anterior Ks, ACD, AQD, and LT interchangeably between CASIA 2 and IOLMaster 700.
Collapse
Affiliation(s)
- Xiaoting Ruan
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - GuangYao Yang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Zhaoxia Xia
- Department of Ophthalmology, The Sixth Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
| | - Jiaqing Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Xiaoxun Gu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Yuan Tan
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Zhenzhen Liu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
- Zhenzhen Liu
| | - Lixia Luo
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
- *Correspondence: Lixia Luo
| |
Collapse
|
2
|
Chen X, Zhang D, Liu Z, Liu Y, Cai H, Wu Q, Zhang Y. Effect of Implantable Collamer Lens on Anterior Segment Measurement and Intraocular Lens Power Calculation Based on IOLMaster 700 and Sirius. J Ophthalmol 2021; 2021:8988479. [PMID: 34970453 DOI: 10.1155/2021/8988479] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Accepted: 12/04/2021] [Indexed: 11/20/2022] Open
Abstract
Purpose To investigate the possible effect of an implantable collamer lens (ICL) on ocular biometrics and intraocular lens (IOL) power calculation. Methods Ocular measurements were taken preoperatively and at the two-month follow-up using IOLMaster 700 and Sirius in 85 eyes (43 patients) who had previously undergone ICL surgery. IOL power was calculated using either IOLMaster 700 (Barrett Universal II formula) or Sirius (ray-tracing). All data were compared using the paired t-test. Results The difference between preoperative and postoperative anterior chamber depth (ACD), lens thickness (LT), and keratometry on the steep axis (K2) measured by IOLMaster 700 was statistically significant (p < 0.001). In 11 of 85 eyes, IOLMaster misjudged the anterior surface of the ICL as that of the lens, leading to an error in ACD and LT. There were no significant differences between preoperative and postoperative axial length (AL) (p = 0.223), white to white (WTW) (p = 0.100), keratometry on flat axis (K1) (p = 0.117), or central corneal thickness (CCT) (p = 0.648), measured using IOLMaster. The difference in IOL power calculated using the Barrett II formula was significant (p = 0.013). Regression analysis showed that AL and K had the greatest influence on IOL calculation (p < 0.001), and ACD and LT had less influence (p = 0.002, p = 0.218, respectively). K1 and K2 were modified to exclude the influence of K2, and modified IOLs showed no difference between pre and postoperation (p = 0.372). Preoperative and postoperative ACD measured using Sirius were significantly different (p < 0.001); however, the IOL power calculated using ray-tracing technology showed no significant differences (p > 0.05). Conclusions The ocular biometric apparatus may misjudge the anterior surface of the lens, resulting in measurement errors of ACD and LT, which has little effect on the calculation of IOL power when using IOLMaster 700 (Barrett Universal II formula) and Sirius (ray-tracing).
Collapse
|