Pinelo A, Almeida P, Loureiro L, Rego D, Teixeira S, Mendes D, Teles P, Sousa C, de Matos N. Use of a Paclitaxel Drug-Eluting Stent for the Treatment of Hemodialysis Access Outflow Stenosis. J Vasc Interv Radiol 2024; 35:384-389. [PMID: 37995865 DOI: 10.1016/j.jvir.2023.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 10/17/2023] [Accepted: 11/13/2023] [Indexed: 11/25/2023] Open
Abstract
PURPOSE To evaluate the outcomes and durability of drug-eluting stents (DESs) for the treatment of hemodialysis access outflow stenosis. MATERIAL AND METHODS A single-center retrospective analysis was conducted of all patients with hemodialysis vascular access outflow stenosis treated with a paclitaxel-coated DES (Eluvia; Boston Scientific, Marlborough, Massachusetts) between January 2020 and July 2022. A total of 34 DESs were implanted to treat outflow stenosis in 32 patients. Primary target lesion patency after stent deployment was the main outcome. Comparison between the time interval free from target lesion reintervention (TLR) after previous plain balloon angioplasty (PBA) and that after stent deployment for the same target lesion was considered a secondary outcome. RESULTS The primary patency at 6, 12, and 18 months was 63.1%, 47.6%, and 41.7%, respectively. The secondary patency rate was 100% at 18 months. The median time interval free from TLR increased from 4.1 to 11.9 months (P < .001). No adverse events were observed during the median follow-up period of 387 days. CONCLUSIONS The patency rates after use of DES for hemodialysis access outflow stenosis were comparable with results for drug-coated balloons and stent grafts, addressing recoil and minimizing the risk of jailing by a covered stent.
Collapse
Affiliation(s)
- Andreia Pinelo
- Grupo de Estudos Vasculares, Vascular Access Center, Porto, Portugal; Department of Angiology and Vascular Surgery, Centro Hospitalar Universitário do Porto, Porto, Portugal.
| | - Paulo Almeida
- Grupo de Estudos Vasculares, Vascular Access Center, Porto, Portugal; Department of Angiology and Vascular Surgery, Centro Hospitalar Universitário do Porto, Porto, Portugal
| | - Luís Loureiro
- Grupo de Estudos Vasculares, Vascular Access Center, Porto, Portugal; Department of Angiology and Vascular Surgery, Centro Hospitalar Universitário do Porto, Porto, Portugal
| | - Duarte Rego
- Grupo de Estudos Vasculares, Vascular Access Center, Porto, Portugal; Department of Angiology and Vascular Surgery, Centro Hospitalar Universitário do Porto, Porto, Portugal
| | - Sérgio Teixeira
- Grupo de Estudos Vasculares, Vascular Access Center, Porto, Portugal; Department of Angiology and Vascular Surgery, Centro Hospitalar Universitário do Porto, Porto, Portugal
| | - Daniel Mendes
- Grupo de Estudos Vasculares, Vascular Access Center, Porto, Portugal; Department of Angiology and Vascular Surgery, Centro Hospitalar Universitário do Porto, Porto, Portugal
| | - Paulo Teles
- Scientific Department of Mathematics and Information Systems, School of Economics and LIAAD-INESC Porto LA, Porto University, Porto, Portugal
| | - Clemente Sousa
- Grupo de Estudos Vasculares, Vascular Access Center, Porto, Portugal; Nursing School Porto, Porto, Portugal
| | - Norton de Matos
- Grupo de Estudos Vasculares, Vascular Access Center, Porto, Portugal
| |
Collapse
|
2
|
Lee K, Won JH, Kwon Y, Lee SH, Bang JB, Kim J. Bare-Metal Stent in Dysfunctional Hemodialysis Access: An Assessment of Circuit Patency according to Access Type and Stent Location. JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY 2023; 84:197-211. [PMID: 36818700 PMCID: PMC9935964 DOI: 10.3348/jksr.2022.0069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2022] [Revised: 06/14/2022] [Accepted: 06/29/2022] [Indexed: 01/21/2023]
Abstract
Purpose To evaluate the circuit patency after nitinol bare-metal stent (BMS) placement according to the type of access and location of the stent in dysfunctional hemodialysis access. Materials and Methods Between January 2017 and December 2019, 159 patients (mean age, 64.1 ± 13.2 years) underwent nitinol BMS placement for dysfunctional access. The location of stents was as follows: 18 brachiocephalic vein, 51 cephalic arch, 40 upper arm vein, 10 juxta-anastomotic vein, 7 arteriovenous (AV) anastomosis, and 33 graft-vein (GV) anastomosis. Circuit patency was evaluated by the Kaplan-Meier method, and cox regression model. Results A total of 159 stents were successfully deployed in 103 AV fistula (AVF) and 56 AV graft (AVG). AVG showed lower primary and secondary patency at 12-months compared with AVF (primary patency; 25.0% vs. 44.7%; p = 0.005, secondary patency; 76.8% vs. 92.2%; p = 0.014). Cox regression model demonstrated poorer primary patency at 12 months after stenting in the cephalic arch and GV anastomosis compared with the other sites. Conclusion AVF showed better primary and secondary circuit patency at 12 months following the placement of BMS compared with AVG. Stents in the cephalic arch and GV anastomosis were associated with poorer primary patency at 12 months compared to those in other locations.
Collapse
Affiliation(s)
- Kyungmin Lee
- Department of Radiology, Ajou University Hospital, Ajou University School of Medicine, Suwon, Korea
| | - Je Hwan Won
- Department of Radiology, Ajou University Hospital, Ajou University School of Medicine, Suwon, Korea
| | - Yohan Kwon
- Department of Radiology, Ajou University Hospital, Ajou University School of Medicine, Suwon, Korea
| | - Su Hyung Lee
- Department of Surgery, Ajou University Hospital, Ajou University School of Medicine, Suwon, Korea
| | - Jun Bae Bang
- Department of Surgery, Ajou University Hospital, Ajou University School of Medicine, Suwon, Korea
| | - Jinoo Kim
- Department of Radiology, Ajou University Hospital, Ajou University School of Medicine, Suwon, Korea
| |
Collapse
|
3
|
Shaikh A, Albalas A, Desiraju B, Dwyer A, Haddad N, Almehmi A. The role of stents in hemodialysis vascular access. J Vasc Access 2023; 24:107-116. [PMID: 33993804 PMCID: PMC10896277 DOI: 10.1177/11297298211015069] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Vascular access is the Achilles' heel of dialysis therapy among patient with end stage kidney disease. The development of neointimal hyperplasia and subsequent stenosis is common in vascular access and is associated with significant morbidity. Percutaneous transluminal angioplasty using balloon inflation was the standard therapy of these lesions. However, the balloon-based approaches were associated with poor vascular access patency rate necessitating new inventions. It is within this context that different types of stents were developed in order to improve the overall dialysis vascular access functionality. In this article, we review the available literature regarding the use of stents in treating dialysis vascular access stenotic lesions. Further, we review the major clinical trials of stent use in different anatomic locations and in different clinical scenarios.
Collapse
Affiliation(s)
- Aisha Shaikh
- Department of Medicine, James J. Peters VA Medical Center, Bronx, NY, USA
| | - Alian Albalas
- Department of Biology, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Brinda Desiraju
- Department of Medicine, SUNY Downstate School of Medicine, Brooklyn, NY, USA
| | - Amy Dwyer
- Department of Medicine, University of Louisville, Louisville, KY, USA
| | - Nabil Haddad
- Department of Medicine, The Ohio State University Medical Center, Columbus, OH, USA
| | - Ammar Almehmi
- Department of Medicine and Radiology, University of Alabama at Birmingham, Birmingham, AL, USA
| |
Collapse
|
4
|
Angioplasty of Dysfunctional Dialysis Fistula or Graft with Resveratrol-Excipient and Paclitaxel-Coated Balloon Improves Primary Patency Rates Compared to Plain Angioplasty Alone. J Clin Med 2022; 11:jcm11247405. [PMID: 36556023 PMCID: PMC9785300 DOI: 10.3390/jcm11247405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/11/2022] [Accepted: 12/12/2022] [Indexed: 12/15/2022] Open
Abstract
In this prospective randomized single-blinded study (reg. ISRCTN11414306), 76 patients with a dysfunctional dialysis fistula or graft due to a single de novo or recurrent stenosis in the access circuit were randomized to receive either conventional PTA (POBA) as a standard of care (n = 38) or PTA + adjunctive PTA with a drug-coated (paclitaxel-resveratrol matrix) SeQuent® Please OTW balloon (n = 38, DCB). Patients were scheduled for follow-up PTA at 3, 6, 9, and 12 months. The time of clinically driven target-lesion reintervention rate (primary patency rate) after the index procedure was analyzed using the log-rank test. The primary patency rates at 12 months after the index procedure were 17% (DCB) vs. 11% (POBA). At 3 months, they were 87% vs. 74%, at 6 months they were 53% vs. 26%, and at 9 months they were 22% vs. 11%. The hazard ratio for DCB was 0.55 (95%CI 0.32 to 0.95). The median time needed for target-lesion reintervention was longer in the DCB group (181 days) than in the conventional PTA group (98 days, p = 0.019). We conclude that PTA with the paclitaxel-resveratrol drug-coated SeQuent® Please OTW balloon in patients with de novo or recurrent stenosis in dialysis arteriovenous fistulas or grafts prolongs the time needed for target lesion reintervention and improves primary patency rates in the first year after the index procedure.
Collapse
|
5
|
Fransson T, Gottsäter A, Abdulrasak M, Malina M, Resch T. Drug-eluting balloon (DEB) versus plain old balloon angioplasty (POBA) in the treatment of failing dialysis access: A prospective randomized trial. J Int Med Res 2022; 50:3000605221081662. [PMID: 35354342 PMCID: PMC8978321 DOI: 10.1177/03000605221081662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Objective To compare the efficacy of angioplasty using drug-eluting balloons (DEB) compared with plain old balloon angioplasty (POBA) to reduce the rate of restenosis. Methods This prospective, single-centre, single-blinded, 1:1 randomized, clinical trial enrolled patients that had primary or restenotic lesions in native upper extremity arteriovenous (AV) fistulas or at the graft-venous anastomosis. Patients were randomized to angioplasty with a POBA or a DEB. The primary effectiveness endpoints were freedom from target lesion revascularization (TLR) and functional status of access circuit at 12 months. Results A total of 42 (28 male, 14 female; age range, 42–83 years) patients were enrolled. Patients were followed for 12 months. No significant differences were detected between the POBA and DEB groups regarding total number of TLR procedures (31 versus 36, respectively), freedom from TLR (3 versus 4, respectively) and functional status of the access circuit at 12 months (14 of 20 patients [70%] versus 17 of 22 patients [77%], respectively). Conclusion This clinical trial did not demonstrate any significant differences between DEB angioplasty and standard balloon angioplasty when treating dysfunctional haemodialysis access.
Collapse
Affiliation(s)
- Torbjörn Fransson
- Department of Thoracic and Vascular Surgery, Skåne University Hospital, Malmö, Sweden.,Department of Clinical Sciences, Faculty of Medicine, Lund University, Malmö, Sweden
| | - Anders Gottsäter
- Department of Internal Medicine, Skåne University Hospital, Malmö, Sweden.,Department of Clinical Sciences, Faculty of Medicine, Lund University, Malmö, Sweden
| | - Mohammad Abdulrasak
- Department of Internal Medicine, Skåne University Hospital, Malmö, Sweden.,Department of Clinical Sciences, Faculty of Medicine, Lund University, Malmö, Sweden
| | - Martin Malina
- West London Vascular and Interventional Centre, Northwick Park University Hospital, Harrow, UK
| | - Timothy Resch
- Department of Vascular Surgery, Rigshospitalet, Copenhagen, Denmark.,Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| |
Collapse
|
6
|
Hongsakul K, Akkakrisee S, Bannangkoon K, Boonsrirat U, Premprabha D, Juntarapatin P. Results of drug-eluting stent in significant restenosis of the hemodialysis access: An initial study. Semin Dial 2021; 35:165-170. [PMID: 34131964 DOI: 10.1111/sdi.12993] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 05/13/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND This study aimed to report the 12-month results of drug-eluting stent (DES) for the treatment of significant restenosis of the hemodialysis access. MATERIALS AND METHODS A total of 14 patients (seven men and seven women; median age 70 years; range of 50-83 years) with significant restenosis of hemodialysis accesses were enrolled from January 2017 to December 2018. A total of 10 arteriovenous graft (AVG) and four arteriovenous fistulae were treated with DES. Study outcomes included primary patency of the target lesion and circuit. RESULTS Venous anastomosis of the AVG was the most common target lesion for DES insertion (nine hemodialysis accesses). The range of follow-up time was 12-36 months. Primary patency rates of target lesion before DES (patency for last conventional balloon angioplasty [CBA]) versus target lesion after DES at 6 and 12 months were 29% versus 100% and 7% versus 86% (p < 0.001). Primary patency rates of pre-DES circuit (patency for last CBA) versus post-DES circuit at 6 and 12 months were 29% versus 64% and 7% versus 29%, respectively (p = 0.058). CONCLUSION DES might improve the patency rate of target lesion in patients with significant restenosis of the hemodialysis access.
Collapse
Affiliation(s)
- Keerati Hongsakul
- Division of Interventional Radiology, Department of Radiology, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| | - Surasit Akkakrisee
- Division of Interventional Radiology, Department of Radiology, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| | - Kittipitch Bannangkoon
- Division of Interventional Radiology, Department of Radiology, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| | - Ussanee Boonsrirat
- Division of Nephrology, Department of Internal Medicine, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| | - Dhanakom Premprabha
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| | - Pong Juntarapatin
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla, Thailand
| |
Collapse
|
7
|
Gu H, Wan Z, Lai QQ, Zhou Y, Tu B, Hu B, Chen L, Gao XJ. Efficacy of ultrasound-guided percutaneous transluminal angioplasty for arteriovenous fistula stenosis or occlusion at juxta-anastomosis: A 3-year follow-up cohort study. J Vasc Surg 2020; 74:217-224. [PMID: 33340700 DOI: 10.1016/j.jvs.2020.11.041] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2020] [Accepted: 11/17/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVE Arteriovenous fistula (AVF) is the preferred access for hemodialysis. Percutaneous transluminal angioplasty (PTA) has become a choice for AVF stenosis, and ultrasound has been used in PTA more frequently. METHODS This single-center retrospective cohort study analyzed 129 patients who underwent PTA in the First Affiliated Hospital of Chongqing Medical University from January 2016 to December 2016. Angioplasty was performed using a noncompliant high-pressure balloon. The process was visualized by duplex scan. Our inclusion criteria were as follows: (1) stenoses or occlusions were located at the juxta-anastomosis site: the first 5 cm of the vein distal to the anastomosis; (2) stenosis was confirmed with the following conditions: (a) flow rates are <500 mL/min in the brachial artery and <200 mL/min in the fistula during dialysis, and (b) the stenosis diameter is <1.7 mm. We used the Kaplan-Meier curve to show the postintervention primary and secondary patency rates of patients with stenosis and occlusion. RESULTS Altogether, 129 patients with 76 males were analyzed. Moreover, 104 have AVFs on the left arm, and only one patient had an ulnar-basilic AVF, whereas others had a radial-cephalic AVF. The postintervention primary patency rates are better in occlusion cases (P < .05), whereas secondary patency rates have no difference. The postintervention primary patency rates are better in patients without diabetes mellitus (P < .05), whereas the secondary patency rates had no difference. CONCLUSIONS For juxta-anastomosis site stenosis or occlusion, PTA can be used to obtain satisfactory results.
Collapse
Affiliation(s)
- Hui Gu
- Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Ziming Wan
- Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
| | - Qi-Quan Lai
- Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Yu Zhou
- Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Bo Tu
- Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Bo Hu
- Department of Nephrology, The First Affiliated Hospital of Jinan University, Guangzhou, China
| | - Ling Chen
- Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Xue-Jing Gao
- Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
8
|
Outcome of Percutaneous Intervention in Dysfunctional Loop versus Straight Arteriovenous Grafts in Hemodialysis Patients. J Belg Soc Radiol 2020; 104:46. [PMID: 32964187 PMCID: PMC7485400 DOI: 10.5334/jbsr.2146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Objective: To compare the patency control of dysfunctioning forearm arteriovenous graft (AVG) using percutaneous transluminal angioplasty (PTA) in patients with loop versus straight grafts. Materials and Methods: Between January 2012 and March 2017, hemodialysis patients with forearm AVG were treated with PTA at two hospitals. We reviewed technical and clinical success rates of each procedure. Procedure time and patency of the graft were compared for all patients as well as for subgroups of stenosis only and thrombosis using paired-sample t-test and Kaplan-Meier analysis. Results: Sixty-six patients (mean age, 62.11 ± 11.85 years) underwent PTA. Thirty-eight patients (58%) had loop grafts and 28 (42%) had straight grafts. Among 66 patients, 54 (82%) had thrombosis. Technical success rate was 95.5% (only stenosis: 100%; thrombosis: 94%) and the mean procedure time was 48.00 ± 16.75 minutes in all patients. Although there was a tendency towards shorter procedure time in patients with loop grafts (45.24 ± 20.24 minutes) than those with straight grafts (51.85 ± 22.76 minutes), the difference was not statistically significant (p = 0.217), with or without thrombi. There was no statistical significance in primary and assisted primary patency (log rank 0.78, p = 0.38 in primary patency; log rank 0.88, p = 0.35 in assisted primary patency). Conclusion: Our study suggests there is no different patency outcome between straight and loop arteriovenous grafts after PTA.
Collapse
|
9
|
Yuan Y, Cheng W, Lu H. Drug-Eluting Balloon Versus Plain Balloon Angioplasty For The Treatment of Failing Hemodialysis Access: A Systematic Review and Meta-analysis. Ann Vasc Surg 2020; 64:389-396. [DOI: 10.1016/j.avsg.2019.10.062] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 09/03/2019] [Accepted: 10/12/2019] [Indexed: 10/25/2022]
|
10
|
Wang T, Wang S, Gu J, Lou W, He X, Chen L, Chen G, Zee C, Chen BT. Transcatheter Thrombolysis with Percutaneous Transluminal Angioplasty Using a Trans-Brachial Approach to Treat Thrombosed Arteriovenous Fistulas. Med Sci Monit 2019; 25:2727-2734. [PMID: 30980711 PMCID: PMC6476234 DOI: 10.12659/msm.915755] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Background Arteriovenous fistulas (AVFs) are used to provide vascular access for hemodialysis in patients with end-stage renal failure. However, stenosis and thrombosis can compromise long-term AVF patency. The objective of this study was to evaluate catheter thrombolysis with percutaneous transluminal angioplasty (PTA), using a trans-brachial approach, for acutely thrombosed AVFs. Material/Methods This retrospective study examined 30 cases of AVF thrombosis treated between January 1, 2015 and January 1, 2017. All patients received transcatheter thrombolysis with PTA using a trans-brachial approach. AVF patency was assessed after 6 months. Results Thrombolysis with PTA was performed at 2 to 72 h after diagnosis of AVF occlusion due to acute thrombosis, and AVF patency was restored in all patients. After 6 months, the primary and secondary patency rates were 76.7% and 93.3%, respectively. For type I stenosis, primary patency was achieved in 10 of 16 patients (62.5%) and secondary patency was achieved in 14 of 16 patients (87.5%). For type II stenosis, primary patency was achieved in 13 of 14 patients (92.9%) and secondary patency was achieved in 14 of 14 patients (100%). Comparing type I and II stenosis, a significant difference was detected in the rates of primary patency (odds ratio=0.909, 95% confidence interval 0.754–1.096, P=0.049), but not secondary patency (P=0.178), after 6 months. Conclusions Our study provides preliminary evidence that catheter-directed thrombolysis with PTA using a trans-brachial approach can achieve high patency rates when used to treat acutely thrombosed AVFs.
Collapse
Affiliation(s)
- Tao Wang
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China (mainland).,Department of Diagnostic Radiology, City of Hope National Medical Center, Duarte, CA, USA
| | - Shukui Wang
- Central Laboratory, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China (mainland)
| | - Jianping Gu
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China (mainland)
| | - Wensheng Lou
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China (mainland)
| | - Xu He
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China (mainland)
| | - Liang Chen
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China (mainland)
| | - Guoping Chen
- Department of Interventional Radiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China (mainland)
| | - Chishing Zee
- Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Bihong T Chen
- Department of Diagnostic Radiology, City of Hope National Medical Center, Duarte, CA, USA
| |
Collapse
|
11
|
Drug-Eluting Balloon Angioplasty for Juxta-Anastomotic Stenoses in Distal Radiocephalic Hemodialysis Fistulas: Long-Term Patency Results. Cardiovasc Intervent Radiol 2019; 42:835-840. [DOI: 10.1007/s00270-019-02213-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Accepted: 03/26/2019] [Indexed: 10/27/2022]
|
12
|
Holden A, Hill AA, Buckley B, Connor B, Semple D, Merrilees S, Marsh E, Alfahad A, Iyer R. Clinical Evaluation of the Cook Advance Enforcer 35 Focal-Force PTA Balloon Catheter for Treatment of Hemodialysis Fistula Stenoses: A Feasibility Study. J Vasc Interv Radiol 2018; 30:61-68. [PMID: 30527650 DOI: 10.1016/j.jvir.2018.08.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Revised: 08/14/2018] [Accepted: 08/15/2018] [Indexed: 11/24/2022] Open
Abstract
PURPOSE A prospective, single-center, single-arm feasibility study evaluated procedural and short-term performance of the Advance Enforcer 35 focal-force percutaneous transluminal angioplasty (PTA) balloon catheter in treating stenoses of mature native arteriovenous (AV) hemodialysis access circuits. MATERIALS AND METHODS Twenty-eight patients undergoing treatment for stenosis of a mature native AV hemodialysis access circuit were enrolled at a single institution. Angiographic assessments of the study lesion were required at baseline and after the procedure. Adjunctive procedures for significant residual stenosis were permitted, and patients had clinical and imaging follow-up for as long as 6 months. RESULTS Treatment with the study balloon was effective in reducing the average percent diameter stenosis of the treated lesion from 66.3% (range, 43.8%-93.3%) before the procedure to 23.7% (range, -6.7% to 51.4%) after the procedure. The average inflation pressure required was 12.3 atm. Only 1 patient required an adjunctive procedure, and all patients could resume normal dialysis following the study procedure. At 3 months, 62.0% of study lesions remained patent, and the 6-month patency rate was 25.1%. Two adverse events associated with the study procedure were reported: access-site hematoma and forearm pain (3.6% each). CONCLUSIONS The results demonstrate safety of the study balloon in treating AV access stenosis. Nominal-diameter angioplasty was achieved at relatively low pressure in most study patients without the use of adjunctive procedures, and resumption of normal dialysis was achieved for all patients.
Collapse
Affiliation(s)
- Andrew Holden
- Department of Interventional Radiology, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand.
| | - Andrew A Hill
- Department of Vascular Surgery, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - Brendan Buckley
- Department of Interventional Radiology, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - Brigid Connor
- Department of Interventional Radiology, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - David Semple
- Department of Renal Medicine, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - Stephen Merrilees
- Department of Interventional Radiology, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - Emma Marsh
- Department of Renal Medicine, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | - Aws Alfahad
- Department of Interventional Radiology, Auckland District Health Board, 2 Park Rd., Grafton, Auckland 9, New Zealand
| | | |
Collapse
|
13
|
Tan RY, Chong TT, Tsai FC, Pang SC, Lee KG, Gogna A, Ong AH, Tan CS. A pilot study on adjunctive use of parametric colour-coded digital subtraction angiography in endovascular interventions of haemodialysis access. BMC Med Imaging 2018; 18:28. [PMID: 30219054 PMCID: PMC6139131 DOI: 10.1186/s12880-018-0270-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Accepted: 08/24/2018] [Indexed: 11/10/2022] Open
Abstract
Background Two-dimensional digital subtraction angiography (DSA) is the gold standard for angiographic evaluation of dysfunctional haemodialysis access. We aim to investigate the utility of parametric colour coded DSA in providing hemodynamic analysis during haemodialysis access interventions. Methods We retrospectively studied 20 patients who underwent access intervention and applied parametric colour-coding on selected DSA acquisitions before and after percutaneous transluminal angioplasty (PTA). The difference in time to peak (dTTP) contrast enhancement and time attenuation curve (TAC) of pre- and post-stenotic regions of interest (ROIs) were obtained and compared after treatment. Results Improvements were seen in mean percent of stenosis after PTA (p < 0.0001) for all cases. Median dTTP improved from 0.52 (IQR 0.26, 0.8) to 0.25 (IQR 0, 0.26) seconds (p = 0.001). Median 50% contrast washout time improved from 0.77 (IQR 0.39, 1.17) to 0.42 (IQR 0.23, 0.59) seconds (p = 0.031). Significant correlation was seen for dTTP vs. percent of stenosis (r = 0.723, p = 0.043) pre-PTA and for change in dTTP vs. percent change in stenosis post-PTA (r = 0.786, p = 0.021) for inflow lesions. Such correlation was however not seen in outflow lesions. Conclusions Adjunctive use of parametric colour-coded DSA may provide potentially useful hemodynamic information during vascular access interventions. Larger prospective studies are needed to validate our findings.
Collapse
Affiliation(s)
- Ru Yu Tan
- Department of Renal Medicine, Singapore General Hospital, Singapore, Singapore.
| | - Tze Tec Chong
- Department of Vascular Surgery, Singapore General Hospital, Singapore, Singapore
| | - Fu Chieh Tsai
- Department of Vascular and Interventional Radiology, Singapore General Hospital, Singapore, Singapore
| | - Suh Chien Pang
- Department of Renal Medicine, Singapore General Hospital, Singapore, Singapore
| | - Kian Guan Lee
- Department of Renal Medicine, Singapore General Hospital, Singapore, Singapore
| | - Apoorva Gogna
- Department of Vascular and Interventional Radiology, Singapore General Hospital, Singapore, Singapore
| | | | - Chieh Suai Tan
- Department of Renal Medicine, Singapore General Hospital, Singapore, Singapore
| |
Collapse
|
14
|
Aktas A, Bozkurt A, Aktas B, Kirbas I. Percutaneous transluminal balloon angioplasty in stenosis of native hemodialysis arteriovenous fistulas: technical success and analysis of factors affecting postprocedural fistula patency. Diagn Interv Radiol 2016; 21:160-6. [PMID: 25698092 DOI: 10.5152/dir.2014.14348] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE We aimed to determine the predictors of technical success and patency after percutaneous transluminal angioplasty (PTA) of de novo dysfunctional hemodialysis arteriovenous fistulas (AVF). METHODS We performed a retrospective analysis of first time PTA in 228 patients (129 men, 99 women; mean age, 56.8±14.6 years). Anatomical (location, length, grade, and number of stenoses) and clinical variables (sex, age, prior AVF, diabetes mellitus, AVF age, side, and location) were reviewed. RESULTS A total of 330 stenoses were found in 228 patients. PTA was technically successful in 96.3% of the stenoses (n=319). Clinical success was achieved in 97.2% (n=321). Early dysfunction (within six months) was positively correlated with patient age (P < 0.001) and diabetes (P < 0.005). Older age (P < 0.001) and diabetes (P = 0.002) were associated with a lower primary patency rate. Patient age (P %lt; 0.001), presence of diabetes (P = 0.023), length of stenosis (P = 0.003), early recurrence (P = 0.003) and presence of residual stenosis (P = 0.014) were associated with a lower secondary patency rate. CONCLUSION Patency of dysfunctional hemodialysis fistulas can be maintained safely with continuous follow-up and repeated interventions without shortening the venous segment by surgical revision. Percutaneous approach to hemodialysis access stenosis is an alternative to the conventional surgical approach and PTA is an effective treatment method for dysfunctional AVF.
Collapse
Affiliation(s)
- Ayse Aktas
- Department of Radiology, Turgut Özal University School of Medicine, Ankara, Turkey.
| | | | | | | |
Collapse
|
15
|
Dariushnia SR, Walker TG, Silberzweig JE, Annamalai G, Krishnamurthy V, Mitchell JW, Swan TL, Wojak JC, Nikolic B, Midia M. Quality Improvement Guidelines for Percutaneous Image-Guided Management of the Thrombosed or Dysfunctional Dialysis Circuit. J Vasc Interv Radiol 2016; 27:1518-30. [DOI: 10.1016/j.jvir.2016.07.015] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2015] [Revised: 07/12/2016] [Accepted: 07/14/2016] [Indexed: 01/20/2023] Open
|
16
|
The primary patency of drug-eluting balloon versus conventional balloon angioplasty in hemodialysis patients with arteriovenous fistula stenoses. Jpn J Radiol 2016; 34:700-704. [DOI: 10.1007/s11604-016-0577-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2016] [Accepted: 08/15/2016] [Indexed: 10/21/2022]
|
17
|
Paclitaxel-Coated Balloon Angioplasty of Venous Stenoses in Native Dialysis Fistulas: Primary and Secondary Patencies at 6 and 12 Months. J Belg Soc Radiol 2016; 100:69. [PMID: 30038986 PMCID: PMC5854225 DOI: 10.5334/jbr-btr.1159] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Purpose: When dialysis access stenoses are dilated by noncoated balloons, respective primary and secondary patencies hardly reach 50 per cent and 85 per cent at one year. This study determines the primary and secondary patency rates at 6 and 12 months for venous stenoses treated by paclitaxel-coated balloon (PCB) angioplasty in native hemodialysis accesses. Materials and Methods: From 2012 to 2014, 70 venous stenoses in 41 patients benefited from PCB angioplasties. The patients’ mean age was 62.5 ± 13.8 years’ standard deviation (SD) with 75 per cent male gender, 31.7 per cent diabetes, and 65.9 per cent arterial hypertension. There were 58.5 per cent forearm fistulas and 41.5 per cent arm fistulas. Primary and secondary patency rates were prospectively established by using the Kaplan-Meier technique and tested by using the log-rank test. Results: The primary patency rates ± SD were 81.4 ± 4.6 per cent and 60 ± 5.9 per cent at 6 and 12 months, respectively. The secondary patency rates ± SD reached 94.3 ± 2.8 per cent at 6 months and 91.4 ± 3.3 per cent at 12 months. Conclusion: This study shows an improvement of the primary and secondary patency rates at 6 and 12 months when venous stenoses of native dialysis fistulas are treated by PCB. The indications for PCB, however, remain to be established by larger randomized studies.
Collapse
|
18
|
Drug-Eluting Balloon for the Treatment of Failing Hemodialytic Radiocephalic Arteriovenous Fistulas: Our Experience in the Treatment of Juxta-Anastomotic Stenoses. J Vasc Access 2014; 15:338-43. [DOI: 10.5301/jva.5000211] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/14/2013] [Indexed: 12/19/2022] Open
Abstract
Purpose The purpose of this article is to report our experience with drug-eluting balloons for the treatment of juxta-anastomotic stenoses of failing radiocephalic hemodialytic arteriovenous shunt and to evaluate the primary and secondary patency (PP and SP). Methods After approval by the local hospital's Ethical and Scientific Review Board, 26 consecutive patients with juxta-anastomotic stenosis of radiocephalic hemodialytic shunt were treated with angioplasty with drug-eluting balloon. The main objective was to evaluate PP defined, in accordance with the Kidney Disease Outcomes Quality Initiative recommendation, as the absence of dysfunction of the vascular access, patent lesion or residual stenosis <30% and no need for further reintervention of the target lesion (TL). PP and SP at 6, 12 and 24 months were evaluated, with echo color doppler and phlebography, for both arteriovenous fistulae, defined as absolute, and TL. Results Immediate postprocedural technical and clinical success was 100% for all the patients; we had only one technical failure in repeated treatments. At 6 months the absolute and TL PP was 96.1%; at 12 months the absolute PP was 81.8%, TL PP 90.9%, absolute SP 95.4%, TL SP 100%; at 24 months the absolute and TL PP was 57.8%; absolute and TL SP 94.7%; only one arteriovenous fistula was lost during the period. Conclusions The use of drug-eluting balloons, after standard angioplasty, improves primary patency and decreases reinterventions of TL in juxta-anastomotic stenoses of failing native dialytic arteriovenous shunts.
Collapse
|
19
|
Is Repeat PTA of a Failing Hemodialysis Fistula Durable? Int J Vasc Med 2014; 2014:369687. [PMID: 24587906 PMCID: PMC3920629 DOI: 10.1155/2014/369687] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2013] [Revised: 11/18/2013] [Accepted: 11/18/2013] [Indexed: 11/18/2022] Open
Abstract
Purpose. Our objective was to evaluate the outcome of percutaneous transluminal angioplasty (PTA) and particularly rePTA in a failing arteriovenous fistula (AV-fistula). Are multiple redilations worthwhile? Patients and Methods. All 159 stenoses of AV fistulas that were treated with PTA, with or without stenting, during 2008 and 2009, were included. Occluded fistulas that were dilated after successful thrombolysis were also included. Median age was 68 (interquartile range 61.5-78.5) years and 75% were male. Results. Seventy-nine (50%) of the primary PTAs required no further reintervention. The primary patency was 61% at 6 months and 42% at 12 months. Eighty (50%) of the stenoses needed at least one reintervention. Primary assisted patency (defined as patency after subsequent reinterventions) was 89% at 6 months and 85% at 12 months. The durability of repeated PTAs was similar to the durability of the primary PTA. However, an early primary PTA carried a higher risk for subsequent reinterventions. Successful dialysis was achieved after 98% of treatments. Nine percent of the stenoses eventually required surgical revision and 13% of the fistulas failed permanently. Conclusion. The present study suggests that most failing AV-fistulas can be salvaged endovascularly. Repeated PTA seems similarly durable as the primary PTA.
Collapse
|
20
|
Kim TK, Park JY, Bae JH, Choi JW, Ryu SK, Kim MJ, Kim JB, Sohn JW. Treatment of pulmonary thromboembolism using Arrow-Trerotola percutaneous thrombolytic device. Yeungnam Univ J Med 2014. [DOI: 10.12701/yujm.2014.31.1.28] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Affiliation(s)
- Tae Kyun Kim
- Department of Cardiology, Eulji General Hospital, Eulji University, Seoul, Korea
| | - Ji Young Park
- Department of Cardiology, Eulji General Hospital, Eulji University, Seoul, Korea
| | - Jun Ho Bae
- Department of Cardiology, Eulji General Hospital, Eulji University, Seoul, Korea
| | - Jae Woong Choi
- Department of Cardiology, Eulji General Hospital, Eulji University, Seoul, Korea
| | - Sung Kee Ryu
- Department of Cardiology, Eulji General Hospital, Eulji University, Seoul, Korea
| | - Min-Jung Kim
- Department of Cardiology, Eulji General Hospital, Eulji University, Seoul, Korea
| | - Jun Bong Kim
- Department of Cardiology, Eulji General Hospital, Eulji University, Seoul, Korea
| | - Jang Won Sohn
- Division of Cardiology, Department of Internal Medicine, College of Medicine, Yeungnam University, Daegu, Korea
| |
Collapse
|