1
|
Lin S, Lin W, Hu T, Yan M, Tang C. Evaluation of the Bonding Strength between Various Dental Zirconia Models and Human Teeth for Dental Posts through In Vitro Aging Tests. Coatings 2021; 11:1017. [DOI: 10.3390/coatings11091017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
In dentistry, root canal treatment reduces support of the tooth, making it necessary to insert a cylindrical body into the treated tooth to strengthen the crown. In the past, metal or fiberglass was often used. However, metal is too different in color from teeth, so the esthetics are poor, and fiberglass is not as strong as metal. Therefore, an alternative is zirconia, which has the characteristics of high light transmittance, esthetics, good biocompatibility, and high breaking strength. The surface morphology and composition of zirconia ceramics are the key to their bond strength with teeth. Therefore, in this study, the surface characteristics of different brands of zirconia commonly used in clinical practice were evaluated in terms of their surface morphology and surface elements. The surface was modified by sandblasting, and its effect on the bonding strength was discussed. Finally, the stability of the material was evaluated through artificial aging. The results showed that the surface roughness of the zirconia specimens increased after sandblasting, whereas the surface microhardness decreased. The shear test results showed that the 3D shape of the zirconia surface could help improve the bonding strength. The bonding strength of DeguDent increased the most after sandblasting. After 20,000 cycles of aging treatment, the shear strength of each specimen decreased. Field emission scanning electron microscopy results showed that the adhesive remained intact on the surface of zirconia, indicating that adhesion failure occurred between the adhesive and the teeth. This confirms that sandblasting can improve the bonding strength of zirconia. Based on the results obtained, it was concluded that the surface roughness of zirconia is the main factor affecting the bond strength.
Collapse
|
2
|
Yang L, Chen B, Meng H, Zhang H, He F, Xie H, Chen C. Bond durability when applying phosphate ester monomer-containing primers vs. self-adhesive resin cements to zirconia: Evaluation after different aging conditions. J Prosthodont Res 2020; 64:193-201. [PMID: 31690540 DOI: 10.1016/j.jpor.2019.06.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Revised: 04/13/2019] [Accepted: 06/13/2019] [Indexed: 11/21/2022]
Abstract
PURPOSE This study aimed to evaluate bond durability when applying 2 phosphate ester monomer-containing self-adhesive resin cements alone, versus a combination of phosphate ester monomer-containing primer conditioning plus 2 conventional resin cements requiring primers, to zirconia after different artificial aging methods. METHODS We cemented air-abraded zirconia plates to composite resin cylinders with self-adhesive resin cements (MS; RU) alone or cemented them with traditional resin cements (ZRV; ZVN) after pre-conditioning with a zirconia primer. A shear bond strength (SBS) test were performed after subjecting them to 19 different aging conditions (n = 15) comprising 30,000× thermocycles, air storage at room temperature (RT), water storage at RT, or at 37 °C for 24 h, 1 week, 1, 3, 6, and 12 months. Zirconia powders mixed with zirconia primer or 2 self-adhesive resin cements were characterized by X-ray photoelectron spectroscopy. RESULTS Groups MS and ZVN obtained the highest SBS after all of aging methods. SBS after 6 months of storage was similar to SBS after 24 h of storage, while both were higher than SBS after 1 year of storage. Water storage at 37 °C provided higher SBS than RT water storage did. We detected a Zr-O-P bond in both self-adhesive resin cement/zirconia powder mixtures. CONCLUSIONS Application of self-adhesive resin cements alone could be an alternative to pre-conditioning with a zirconia primer followed by the application of conventional resin cements. Formation of Zr-O-P bonds contributed to the bonding improvement of self-adhesive resin cements. Different aging conditions affected SBS values.
Collapse
|
3
|
Aung SSMP, Takagaki T, Lyann SK, Ikeda M, Inokoshi M, Sadr A, Nikaido T, Tagami J. Effects of alumina-blasting pressure on the bonding to super/ultra-translucent zirconia. Dent Mater 2019; 35:730-739. [PMID: 30826073 DOI: 10.1016/j.dental.2019.02.025] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Accepted: 02/13/2019] [Indexed: 02/07/2023]
Abstract
OBJECTIVES Translucent zirconia has brought the advantages such as less tooth preparation, biological compatibility, high strength, good mechanical properties, and less antagonist wear. This study's aim was to elucidate how clinically relevant surface treatments; alumina-abrasion and priming effect on bond strength of Y-PSZ in three different translucency grades after long-term water storage. MATERIALS AND METHODS Three highly translucent Y-PSZ grades were ground flat with #600-grit SiC paper. Four different surface treatments (untreated, alumina blasting at 0.1 MPa or 0.2 MPa or 0.4 MPa) and two resin cements (PANAVIA V5 and PANAVIA SA CEMENT PLUS AUTOMIX) were tested. The bonded specimens were stored in water for 1 day, 30 days and 150 days and tensile bond strength (TBS) were measured with universal testing machine at a crosshead speed of 2 mm/min (n=10). The surface roughness (Sa) measurement and surface morphology analysis without alumina-blasting pressure (untreated) and with alumina-blasting pressures (0.1 MPa, 0.2 MPa and 0.4 MPa) for three different zirconia grades were evaluated with 3D-Laser Scanning Confocal Microscope. RESULTS Different alumina-blasting pressures and different storage periods affected the bonding of resin cement to translucent zirconia. The Weibull moduli increased in some groups after 150 days storage. After 1 day and 30 days storage, 0.4 MPa alumina-blasting pressure provided superior bond strength, however, after 150 days, 0.2 MPa gave reliable and stable bond strength. SIGNIFICANCE Alumina-blasting pressure of 0.2 MPa was the most effective for reliable and durable bonding performance to translucent zirconia after long-term water storage.
Collapse
Affiliation(s)
- San San May Phyo Aung
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Tomohiro Takagaki
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan.
| | - Sai Kham Lyann
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Masaomi Ikeda
- Department of Oral Prosthetic Engineering, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Masanao Inokoshi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8510, Japan
| | - Alireza Sadr
- Biomimetics Biomaterials Biophotonics & Technology Laboratory, Department of Restorative Dentistry, University of Washington School of Dentistry, 1959 NE Pacific St. Box 357456, Seatle, WA, 98195-7456, USA
| | - Toru Nikaido
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan; Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University, Hozumi 1851, Mizuho, Gifu 501-0296, Japan
| | - Junji Tagami
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| |
Collapse
|
4
|
Moura DMD, do Nascimento Januário AB, de Araújo AMM, de Oliveira Dal Piva AM, Özcan M, Bottino MA, Souza ROA. Effect of primer-cement systems with different functional phosphate monomers on the adhesion of zirconia to dentin. J Mech Behav Biomed Mater 2018; 88:69-77. [DOI: 10.1016/j.jmbbm.2018.08.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2018] [Revised: 08/02/2018] [Accepted: 08/03/2018] [Indexed: 11/28/2022]
|