Komarraju A, Maxwell C, Kung JW, Mhuircheartaigh JN, Kim W, Wu JS. Causes and diagnostic utility of musculoskeletal MRI recall examinations.
Clin Radiol 2023;
78:e221-e226. [PMID:
36517267 DOI:
10.1016/j.crad.2022.11.004]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 10/30/2022] [Accepted: 11/05/2022] [Indexed: 12/15/2022]
Abstract
AIM
To determine the causes and diagnostic utility of musculoskeletal (MSK) magnetic resonance imaging (MRI) recall examinations.
MATERIALS AND METHODS
An institutional review board-approved retrospective review was conducted of all MSK MRI examinations performed at a single academic institution over 10 years where radiologists requested the patient return for additional imaging. The reason for the recall was documented. Recalls were reviewed in consensus by two MSK radiologists to determine whether additional sequences resulted in a change in the final report. Recall causes were divided into four categories: (1) radiologist-related: incorrect field of view (FOV) or incorrect protocol; (2) technologist-related: incorrect FOV or incorrect/incomplete protocol performed, or technically poor-quality images; (3) patient-related motion artefact; (4) unexpected lesion discovered. Fisher's exact test was used to assess for statistical significance.
RESULTS
The recall rate was 0.25% (156/62,930). Of the total 129 recalls returning for imaging, 42 (33%) were radiologist-related, 45 (35%) were technologist-related, six (5%) were patient-related, and 36 (28%) had an unexpected lesion requiring additional sequences. For clinical utility, 42% resulted in a change from the initial report. Recalls due to radiologist error, incorrect FOV, or unexpected lesion caused a significant change in the final report; however, recalls due to technologist error, patient motion artefact, or incorrect protocol did not.
CONCLUSION
MRI MSK recalls are uncommon, and the most common reasons are incorrect FOV, incorrect protocol, and unexpected lesion. Radiologist-related errors in protocols and FOV led to a significant change in the final report and should be targeted as areas for improvement to reduce recall examinations.