1
|
Bazaga S, García-Alonso FJ, Aparicio Tormo JR, Martinez Moreno B, Sanchiz V, Gornals JB, Loras C, Terán Á, Vazquez-Sequeiros E, Pedraza Sanz R, Súbtil JC, Pérez-Millan A, Uceda Porta F, Vila JJ, de la Serna-Higuera C, Couto-Worner I, Guarner-Argente C, Perez-Miranda M. Endoscopic ultrasound-guided gallbladder drainage with long-term lumen-apposing metal stent indwell: 1-year results from a prospective nationwide observational study. J Gastroenterol Hepatol 2024; 39:360-368. [PMID: 37920889 DOI: 10.1111/jgh.16392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 10/10/2023] [Accepted: 10/12/2023] [Indexed: 11/04/2023]
Abstract
BACKGROUND AND AIM This study aimed to determine safety and risk factors for adverse events (AEs) of endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) with long-term indwell of lumen-apposing metal stents (LAMS). METHODS This study is a multicenter prospective observational study on consecutive high surgical-risk patients requiring gallbladder drainage who underwent EUS-GBD with LAMS over 12 months. Centralized telephone follow-up interviews were conducted every 3 months for 1 year. Patients were censored at LAMS removal, cholecystectomy, or death. AE-free survival was determined using log-rank tests. Cumulative risks were estimated using life-table analysis. RESULTS Eighty-two patients were included (53.7% male, median [interquartile range] age of 84.6 [76.5-89.8] years, and 85.4% with acute cholecystitis). Technical success was achieved in 79 (96.3%), and clinical success in 73 (89%). No patient was lost to follow-up; 45 patients (54.9%) completed 1-year follow-up with in situ LAMS. Median (interquartile range) LAMS indwell time was 364 (47-367) days. Overall, 12 (14.6%) patients presented 14 AEs, including 5 (6.1%) recurrent biliary events (3 acute cholangitis, 1 mild acute pancreatitis, and 1 acute cholecystitis). Patients with pancreatobiliary malignancy had an increased risk of recurrent biliary events (33% vs 1.5%, P = 0.001). The overall 1-year cumulative risk of recurrent biliary events was 9.7% (4.1-21.8%). The 1-year risk of AEs and of severe AEs was 18.8% (11-31.2%) and 7.9% (3.3-18.2%), respectively. Pancreatobiliary malignancy was the single risk factor for recurrent biliary events; LAMS misdeployment was the strongest risk factor for AEs. CONCLUSIONS Long-term LAMS indwell does not increase the risk of delayed AEs following EUS-GBD.
Collapse
Affiliation(s)
- Sergio Bazaga
- Department of Gastroenterology, Hospital Universitario Rio Hortega, Valladolid, Spain
- Department of Medicine, Universitat Autónoma de Barcelona, Universitat Autònoma de Barcelona, Barcelona, Spain
| | | | | | | | | | - Joan B Gornals
- Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
| | - Carme Loras
- Department of Gastroenterology, Hospital Universitari Mútua Terrassa, Fundació per la Recerca Mútua Terrassa, Terrassa, Spain
- Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd), Barcelona, Spain
| | - Álvaro Terán
- Hospital Universitario Marqués de Valdecilla, Santander, Spain
| | - Enrique Vazquez-Sequeiros
- Endoscopy Unit, Department of Gastroenterology and Hepatology, Hospital Ramón y Cajal, IRYCIS, Madrid, Spain
| | | | - José Carlos Súbtil
- Department of Gastroenterology, Endoscopy Unit, University of Navarra Clinic, University of Navarra, Pamplona, Spain
| | | | | | - Juan J Vila
- Complejo Hospitalario de Navarra, Pamplona, Spain
| | | | | | - Carlos Guarner-Argente
- Department of Medicine, Universitat Autónoma de Barcelona, Universitat Autònoma de Barcelona, Barcelona, Spain
- Department of Gastroenterology, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Manuel Perez-Miranda
- Department of Gastroenterology, Hospital Universitario Rio Hortega, Valladolid, Spain
| |
Collapse
|
2
|
Bazaga S, García-Alonso FJ, Aparicio Tormo JR, Martinez Moreno B, Sanchiz V, Suria C, Garcia-Sumalla A, Gornals JB, Chavarría C, Loras C, García-Fernandez FJ, Terán Á, Vazquez-Sequeiros E, Pedraza Sanz R, Pérez-Carazo L, Súbtil JC, Pérez-Millan A, Uceda Porta F, Busto Bea V, de la Serna-Higuera C, Pinto Garcia I, Colán-Hernández J, Huertas C, Guarner-Argente C, Perez-Miranda M. Endoscopic removal of lumen-apposing metal stents - risk factors for stent embedment, complex removals, and adverse events: analysis from a multicenter prospective case series. Endoscopy 2023; 55:591-598. [PMID: 36882089 DOI: 10.1055/a-2030-4158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/09/2023]
Abstract
BACKGROUND Removing lumen-apposing metal stents (LAMSs) may be difficult and even harmful, but these features have seldom been analyzed. We aimed to generate a comprehensive assessment of the feasibility and safety of LAMS retrieval procedures. METHODS A prospective multicenter case series including all technically successfully deployed LAMSs between January 2019 and January 2020 that underwent endoscopic stent removal. All retrieval-related data were prospectively recorded using standardized telephone questionnaires as part of centralized follow-up that ended after stent removal had been performed. Multivariable logistic regression models assessed the potential risk factors for complex removal. RESULTS For the 407 LAMSs included, removal was attempted in 158 (38.8 %) after an indwell time of 46.5 days (interquartile range [IQR] 31-70). The median (IQR) removal time was 2 (1-4) minutes. Removal was labelled as complex in 13 procedures (8.2 %), although advanced endoscopic maneuvers were required in only two (1.3 %). Complex removal risk factors were stent embedment (relative risk [RR] 5.84, 95 %CI 2.14-15.89; P = 0.001), over-the-wire deployment (RR 4.66, 95 %CI 1.60-13.56; P = 0.01), and longer indwell times (RR 1.14, 95 %CI 1.03-1.27; P = 0.01). Partial and complete embedment were observed in 14 (8.9 %) and five cases (3.2 %), respectively. The embedment rate during the first 6 weeks was 3.1 % (2/65), reaching 15.9 % (10/63) during the following 6 weeks (P = 0.02). The adverse event rate was 5.1 %, including seven gastrointestinal bleeds (5 mild, 2 moderate). CONCLUSIONS LAMS removal is a safe procedure, mostly requiring basic endoscopic techniques attainable in conventional endoscopy rooms. Referral to advanced endoscopy units should be considered for stents with known embedment or long indwell times, which may require more technically demanding procedures.
Collapse
Affiliation(s)
- Sergio Bazaga
- Department of Gastroenterology, Hospital Universitario Rio Hortega, Valladolid, Spain
- Universitat Autònoma de Barcelona, Barcelona, Spain
| | | | | | | | | | - Carles Suria
- Hospital Clínico Universitario de Valencia, Valencia, Spain
| | - Albert Garcia-Sumalla
- Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
| | - Joan B Gornals
- Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
| | - Carlos Chavarría
- Department of Gastroenterology, Hospital Universitario Rio Hortega, Valladolid, Spain
| | - Carme Loras
- Department of Gastroenterology, Hospital Universitari Mútua Terrassa, Fundació per la Recerca Mútua Terrassa, Barcelona, Spain
- Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd), Spain
| | | | - Álvaro Terán
- Hospital Universitario Marqués de Valdecilla, Santander, Spain
| | - Enrique Vazquez-Sequeiros
- Endoscopy Unit, Department of Gastroenterology and Hepatology, Hospital Ramón y Cajal, IRYCIS, Madrid, Spain
| | | | | | - José Carlos Súbtil
- Department of Gastroenterology, Endoscopy Unit, University of Navarra Clinic, University of Navarra, Pamplona, Spain
| | | | | | | | | | | | | | - Carlos Huertas
- Hospital Universitari de Girona Josep Trueta, Girona, Spain
| | - Carlos Guarner-Argente
- Universitat Autònoma de Barcelona, Barcelona, Spain
- Department of Gastroenterology, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Manuel Perez-Miranda
- Department of Gastroenterology, Hospital Universitario Rio Hortega, Valladolid, Spain
| |
Collapse
|
3
|
Bazaga S, García-Alonso FJ, Aparicio Tormo JR, Martinez Moreno B, Sanchiz V, Suria C, Garcia-Sumalla A, Gornals JB, Chavarría C, Loras C, García-Fernandez FJ, Terán Á, Vazquez-Sequeiros E, Pedraza Sanz R, Pérez-Carazo L, Súbtil JC, Pérez-Millan A, Uceda Porta F, Busto Bea V, de la Serna-Higuera C, Pinto Garcia I, Colán-Hernández J, Huertas C, Guarner-Argente C, Perez-Miranda M. Correction: Endoscopic removal of lumen-apposing metal stents - risk factors for stent embedment, complex removals, and adverse events: analysis from a multicenter prospective case series. Endoscopy 2023; 55:C8. [PMID: 38016667 DOI: 10.1055/a-2215-2453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2023]
Affiliation(s)
- Sergio Bazaga
- Department of Gastroenterology, Hospital Universitario Rio Hortega, Valladolid, Spain
- Department of Medicine, Universitat Autònoma de Barcelona, Barcelona, Spain
| | | | | | | | | | - Carles Suria
- Hospital Clínico Universitario de Valencia, Valencia, Spain
| | - Albert Garcia-Sumalla
- Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
| | - Joan B Gornals
- Endoscopy Unit, Department of Digestive Diseases, Hospital Universitari de Bellvitge, Bellvitge Biomedical Research Institute (IDIBELL), University of Barcelona, Barcelona, Spain
| | - Carlos Chavarría
- Department of Gastroenterology, Hospital Universitario Rio Hortega, Valladolid, Spain
| | - Carme Loras
- Department of Gastroenterology, Hospital Universitari Mútua Terrassa, Fundació per la Recerca Mútua Terrassa, Barcelona, Spain
- Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd), Spain
| | | | - Álvaro Terán
- Hospital Universitario Marqués de Valdecilla, Santander, Spain
| | - Enrique Vazquez-Sequeiros
- Endoscopy Unit, Department of Gastroenterology and Hepatology, Hospital Ramón y Cajal, IRYCIS, Madrid, Spain
| | | | | | - José Carlos Súbtil
- Department of Gastroenterology, Endoscopy Unit, University of Navarra Clinic, University of Navarra, Pamplona, Spain
| | | | | | | | | | | | | | - Carlos Huertas
- Hospital Universitari de Girona Josep Trueta, Girona, Spain
| | - Carlos Guarner-Argente
- Department of Gastroenterology, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Manuel Perez-Miranda
- Department of Gastroenterology, Hospital Universitario Rio Hortega, Valladolid, Spain
| |
Collapse
|