1
|
Volle C, Núñez ME, Spain EM, Hart BC, Wengen MB, Lane S, Criollo A, Mahoney CA, Ferguson MA. AFM Force Mapping Elucidates Pilus Deployment and Key Lifestyle-Dependent Surface Properties in Bdellovibrio bacteriovorus. Langmuir 2023; 39:4233-4244. [PMID: 36926913 PMCID: PMC10062353 DOI: 10.1021/acs.langmuir.2c03134] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 03/03/2023] [Indexed: 06/18/2023]
Abstract
Bdellovibrio bacteriovorus is known for predation of a wide variety of Gram-negative bacteria, making it of interest as an alternative or supplement to chemical antibiotics. However, a fraction of B. bacteriovorus follows a nonpredatory, "host-independent" (HI) life cycle. In this study, live predatory and HI B. bacteriovorus were captured on a surface and examined, in buffer, by collecting force maps using atomic force microscopy (AFM). The approach curves obtained on HI cells are similar to those on other Gram-negative cells, with a short nonlinear region followed by a linear region. In contrast, the approach curves obtained on predatory cells have a large nonlinear region, reflecting the unusual flexibility of the predatory cell. As the AFM tip is retracted, it shows virtually no adhesion to predatory B. bacteriovorus but has multiple adhesion events on HI cells and the 200-500+ nm region immediately surrounding them. Measured pull-off forces, pull-off distances, and effective spring constants are consistent with the multiple stretching events of Type IV pili, both on and especially adjacent to the cells. Exposure of the HI B. bacteriovorus to a pH-neutral 10% cranberry juice solution, which contains type A proanthocyanidins that are known to interfere with the adhesion of multiple types of pili, results in a substantial reduction in adhesion. Type IV pili are required for successful predation by B. bacteriovorus, but pili used in the predation process are located at the non-flagellated pole of the cell and can retract when not in use. Such pili are rarely observed under the conditions of this study, where the predator has not encountered a prey cell. In contrast, HI cells appear to have many pili distributed on and around the whole cell, presumably ready to be utilized for a variety of HI cell activities including attachment to surfaces.
Collapse
Affiliation(s)
- Catherine
B. Volle
- Departments
of Chemistry and Biology, Cornell College, Mount Vernon, Iowa 52314, United States
| | - Megan E. Núñez
- Department
of Chemistry, Wellesley College, Wellesley, Massachusetts 02481, United States
| | - Eileen M. Spain
- Department
of Chemistry, Occidental College, Los Angeles, California 90041, United States
| | - Bridget C. Hart
- Department
of Chemistry, State University of New York, New Paltz, New York 12561, United States
| | - Michael B. Wengen
- Department
of Chemistry, State University of New York, New Paltz, New York 12561, United States
| | - Sophia Lane
- Department
of Chemistry, State University of New York, New Paltz, New York 12561, United States
| | - Alexa Criollo
- Department
of Chemistry, State University of New York, New Paltz, New York 12561, United States
| | - Catherine A. Mahoney
- Department
of Chemistry, State University of New York, New Paltz, New York 12561, United States
| | - Megan A. Ferguson
- Department
of Chemistry, State University of New York, New Paltz, New York 12561, United States
| |
Collapse
|
2
|
Allt-Graham J, Hart BC. Inspired oxygen and Cape Bristol ventilators. Anaesthesia 1979; 34:198-201. [PMID: 286561 DOI: 10.1111/j.1365-2044.1979.tb06279.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The Cape Bristol ventilator is a volume-preset machine which utilises oxygen from a flowmeter and air-entrainment attachment to provide a known inspired oxygen level. The level can be calculated from the oxygen flow rate and the patient's minute ventilation using a nomogram supplied by the manufacturers. Serious discrepancies between predicted and measured inspired oxygen levels delivered by these machines can occur and the advisability of using air entrainment devices in high oxygen dependent patients is questioned. Modification to the Cape Bristol ventilator to limit these errors are discussed and the more frequent use of oxygen monitors recommended.
Collapse
|