1
|
Meierhans R, Gelpke H, Hetzel J, Madjdpour C. Bronchoscope-assisted Tritube® placement for resection of sequential tracheal stenosis. Anaesth Rep 2022; 10:e12195. [PMID: 36439297 PMCID: PMC9681651 DOI: 10.1002/anr3.12195] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/07/2022] [Indexed: 11/24/2023] Open
Abstract
Symptomatic tracheal stenosis is a rare but significant complication of long-term tracheal intubation and mechanical ventilation. Airway management for tracheal resection in severe tracheal stenosis, especially sequential stenoses, requires multidisciplinary planning. A valuable method of airway management is the insertion of a small-bore, cuffed tracheal tube (Tritube®, Ventinova Medical B.V., Eindhoven, The Netherlands) in combination with flow-controlled ventilation. In this case, a patient with tracheal stenosis following prolonged ventilation required resection of the stenosed tissue. A Tritube was placed via a J-tipped guidewire inserted through the working channel of a bronchoscope. Bronchoscopic cuff visualisation along the tube in severe stenosis is impossible because of the outer diameter of the tracheal tube. In this case, we therefore estimated the position of the tube tip based on the distance from the vocal cords to the carina measured on pre-operative computed tomography imaging. During completion of the dorsal tracheal anastomosis, cross field ventilation using a conventional tracheal tube had to be started due to impeded ventilation caused by the Tritube protruding distal to the carina. In severe sequential tracheal stenosis, a small-bore tracheal tube can safely be placed by guidance with a J-tipped guidewire. However, it is important to plan a backup method of ventilation, such as cross field ventilation, prior to commencing a critical procedure.
Collapse
Affiliation(s)
- R. Meierhans
- Department of AnaesthesiologyCantonal HospitalWinterthurSwitzerland
| | - H. Gelpke
- Department of Visceral and Thoracic SurgeryCantonal HospitalWinterthurSwitzerland
| | - J. Hetzel
- Department of PneumologyCantonal HospitalWinterthurSwitzerland
| | - C. Madjdpour
- Department of AnaesthesiologyCantonal HospitalWinterthurSwitzerland
| |
Collapse
|
2
|
Abdallah FW, Patel V, Madjdpour C, Cil T, Brull R. Quality of recovery scores in deep serratus anterior plane block vs. sham block in ambulatory breast cancer surgery: a randomised controlled trial. Anaesthesia 2021; 76:1190-1197. [PMID: 33492696 DOI: 10.1111/anae.15373] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/07/2020] [Indexed: 12/13/2022]
Abstract
Deep serratus anterior plane block has been widely adopted as an analgesic adjunct for patients undergoing breast surgery, but robust supporting evidence of efficacy is lacking. We randomly allocated 40 patients undergoing simple or partial mastectomy with sentinel node biopsy to receive either a pre-operative deep serratus anterior plane block (serratus group) or a placebo injection (sham group), in addition to systemic analgesia. The primary outcome measure was the quality of recovery score at discharge, as assessed by the quality of recovery-15 questionnaire at various time-points. Secondary analgesic outcomes included: pain severity; postoperative opioid consumption; opioid-related side-effects; patient satisfaction up to 7 days postoperatively; and persistent postoperative pain up to 3 months after surgery. All patients who were recruited completed the study. There were no differences in the quality of recovery-15 scores between patients in the serratus and control groups, with mean (SD) scores of 96 (14) and 102 (20) for the control and serratus groups, respectively. We were also unable to detect differences in any of the secondary analgesic outcomes examined. The addition of a deep serratus anterior plane block to systemic analgesia does not enhance quality of recovery in patients undergoing ambulatory breast cancer surgery.
Collapse
Affiliation(s)
- F W Abdallah
- Department of Anesthesiology and Pain Medicine, University of Ottawa and University of Toronto, ON, Canada
| | - V Patel
- Department of Anesthesiology and Pain Medicine, Toronto Western Hospital, Toronto, ON, Canada
| | - C Madjdpour
- Anaesthetics Department, Northumbria Healthcare NHS Foundation Trust, North Tyneside General Hospital, North Shields, UK
| | - T Cil
- Department of Surgery, Women's College Hospital, Toronto, ON, Canada
| | - R Brull
- Department of Anesthesiology and Pain Medicine, Toronto Western Hospital, Toronto, ON, Canada
| |
Collapse
|
3
|
El-Boghdadly K, Madjdpour C, Chin K. Thoracic paravertebral blocks in abdominal surgery – a systematic review of randomized controlled trials. Br J Anaesth 2016; 117:297-308. [DOI: 10.1093/bja/aew269] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
4
|
|
5
|
Haas T, Spielmann N, Mauch J, Madjdpour C, Speer O, Schmugge M, Weiss M. Comparison of thromboelastometry (ROTEM®) with standard plasmatic coagulation testing in paediatric surgery. Br J Anaesth 2011; 108:36-41. [PMID: 22086509 DOI: 10.1093/bja/aer342] [Citation(s) in RCA: 267] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Thromboelastometry (ROTEM(®)) might be useful to detect intraoperative coagulation disorders early in major paediatric surgery. This observational trial compares this technique to standard coagulation tests. METHODS Intraoperative blood sampling was obtained in children undergoing elective major surgery. At each time point, standard coagulation tests [activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen level] and ROTEM(®) analyses (InTEM, ExTEM, and FibTEM) were performed simultaneously by trained hospital laboratory staff. RESULTS A total of 288 blood samples from 50 subjects were analysed. While there was a poor correlation between PT and aPTT to ExTEM clotting time (CT) and InTEM CT, respectively, a good correlation was detected between PT and aPTT to clot formation time, and a very good correlation between fibrinogen level and FibTEM assay (r=0.882, P<0.001). Notably, 64% of PT and 94% of aPTT measurements were outside the reference range, while impaired CT was observed in 13% and 6.3%, respectively. Standard coagulation test results were available after a median of 53 min [inter-quartile range (IQR): 45-63 min], whereas 10 min values of ROTEM(®) results were available online after 23 min (IQR: 21-24 min). CONCLUSIONS PT and aPTT cannot be interchangeably used with ROTEM(®) CT. Based on the results of ROTEM(®), recommended thresholds for PT and aPTT might overestimate the need for coagulation therapy. A good correlation was found between the fibrinogen level and the FibTEM assay. In addition, ROTEM(®) offered faster turnaround times.
Collapse
Affiliation(s)
- T Haas
- Department of Anaesthesia, University Children’s Hospital Zurich, Steinwiesstrasse 75, Zurich 8032, Switzerland.
| | | | | | | | | | | | | |
Collapse
|
6
|
Mauch J, Kutter A, Madjdpour C, Spielmann N, Balmer C, Frotzler A, Bettschart-Wolfensberger R, Weiss M. Electrocardiographic changes during continuous intravenous application of bupivacaine in neonatal pigs. Br J Anaesth 2010; 105:437-41. [DOI: 10.1093/bja/aeq197] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
7
|
Dave M, Frotzler A, Spielmann N, Madjdpour C, Weiss M. Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study. Br J Anaesth 2010; 105:538-43. [DOI: 10.1093/bja/aeq202] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
|
8
|
Mauch J, Kutter A, Madjdpour C, Koepfer N, Frotzler A, Bettschart-Wolfensberger R, Weiss M. Electrocardiographic alterations during intravascular application of three different test doses of bupivacaine and epinephrine: experimental study in neonatal pigs. Br J Anaesth 2010; 104:94-7. [DOI: 10.1093/bja/aep313] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
9
|
Weiss M, Doell C, Koepfer N, Madjdpour C, Woitzek K, Bernet V. Rapid pressure compensation by automated cuff pressure controllers worsens sealing in tracheal tubes. Br J Anaesth 2009; 102:273-8. [DOI: 10.1093/bja/aen355] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
10
|
Madjdpour C, Heindl V, Spahn DR. Risks, benefits, alternatives and indications of allogenic blood transfusions. Minerva Anestesiol 2006; 72:283-98. [PMID: 16675937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Allogeneic red blood cell (RBC) transfusions are associated with multiple disadvantages, such as limited availability, high costs, multiple risks and side effects. In addition, large outcome studies comparing liberal (hemoglobin transfusion trigger range 9-10 g/dL) and restrictive (hemoglobin transfusion trigger range 7-9 g/dL) transfusion regimens still need to be performed for surgical patients. Different transfusion alternatives are known for the pre-, intra- and postoperative period. Autologous blood donation and erythropoietin are efficacious in the preoperative period. Intraoperatively, acute normovolemic hemodilution (ANH), cell salvage, antifibrinolytics, specific anesthetic and surgical techniques, coagulation monitoring, acceptance of minimal hemoglobin values and hopefully soon artificial oxygen carriers can reduce allogeneic RBC transfusions. In the postoperative period cell salvage, antifibrinolytics, and accepting minimal hemoglobin values represent alternatives to RBC transfusions. When treating a bleeding patient, the initial administration of crystalloids and colloids to restore and maintain normovolemia is important. RBC transfusions are recommended under the following circumstances: for hemoglobin levels <6 g/dL and for physiologic signs of inadequate oxygenation such as hemodynamic instability, oxygen extraction rate >50% and myocardial ischemia, detectable by new ST-segment depressions >0.1 mV, new ST-segment elevations >0.2 mV or new wall motion abnormalities by transesophageal echocardiography. The aim of this article is to review the efficacy, risk and side effects of RBC transfusions, to discuss transfusion alternatives and to summarize current indications for RBC transfusions. This information will help the physician to judiciously use RBC transfusions when they are indeed indicated.
Collapse
Affiliation(s)
- C Madjdpour
- Department of Anesthesiology, University Hospital Lausanne, Lausanne, Switzerland
| | | | | |
Collapse
|
11
|
von Roten I, Madjdpour C, Frascarolo P, Burmeister MA, Fisch A, Schramm S, Bombeli T, Spahn DR. Molar substitution and C2/C6 ratio of hydroxyethyl starch: influence on blood coagulation. Br J Anaesth 2006; 96:455-63. [PMID: 16464978 DOI: 10.1093/bja/ael019] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Development of hydroxyethyl starches (HES) with a low impact on blood coagulation but a long intravascular persistence is of clinical interest. A previous in vitro study showed that low substituted high molecular weight HES does not compromise blood coagulation more than medium molecular weight HES. In the present study we assessed the individual effects on blood coagulation of molar substitution and C2/C6 ratio of a high molecular weight HES. METHODS Blood was obtained from 30 healthy patients undergoing elective surgery and mixed with six high molecular weight (700 kDa) HES solutions differing in their molar substitution (0.42 and 0.51) and C2/C6 ratio (2.7, 7 and 14) to achieve 20, 40 and 60% dilution. Blood coagulation was assessed by Thrombelastograph analysis (TEG) and plasma coagulation tests. Data were compared using a three-way analysis of variance model with repeated measures on the three factors. RESULTS Higher molar substitution compromised blood coagulation most (for all TEG parameters, P<0.05). The lowest C2/C6 ratio was associated with the lowest effect on blood coagulation; r (P<0.001), angle alpha (P=0.003) and coagulation index (P<0.001). No effect on k and maximum amplitude was observed (P for both >0.50). The higher molar substitution was associated with a lesser increase in PT (P=0.007) and a greater decrease in factor VIII (P=0.010). PTT, functional and antigenic von Willebrand factors were not significantly influenced by molar substitution (P for all >0.20). No significant differences between solutions with the same molar substitution but different C2/C6 ratios were found in plasma coagulation parameters (P for all >0.05). CONCLUSIONS TEG analysis indicates that high molecular HES with a molar substitution of 0.42 and a C2/C6 ratio of 2.7 has the lowest effect on in vitro human blood coagulation.
Collapse
Affiliation(s)
- I von Roten
- Department of Anaesthesiology, University Hospital Lausanne, Lausanne, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Madjdpour C, Dettori N, Frascarolo P, Burki M, Boll M, Fisch A, Bombeli T, Spahn DR. Molecular weight of hydroxyethyl starch: is there an effect on blood coagulation and pharmacokinetics? ‡ ‡Declaration of interest. This study was funded in part by B. Braun, of which MB and AF are employees and DS is a paid consultant. B. Braun has funded other research in this department in the past, as have other competitor companies. Br J Anaesth 2005; 94:569-76. [PMID: 15734780 DOI: 10.1093/bja/aei108] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. METHODS Thirty pigs were infused with three different HES solutions (20 ml kg(-1)) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. RESULTS Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre(-1), P<0.001, 1701 (321) g min litre(-1), P<0.001] than HES 130 [1156 (223) g min litre(-1)] and alpha half life (t(alpha)(1/2)) was longer for HES 500 [53.8 (8.6) min, P<0.01] and HES 900 [57.1 (12.3) min, P<0.01] than for HES 130 [39.9 (10.7) min]. Beta half life (t(beta)(1/2)), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. CONCLUSIONS In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight low-substituted HES might result in a longer lasting volume effect.
Collapse
Affiliation(s)
- C Madjdpour
- Department of Anaesthesiology, University Hospital Lausanne, CH-1011 Lausanne, Switzerland.
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Abstract
Surgical blood loss and trauma are the major causes of allogeneic blood transfusions, which still bear considerable risks. After the correction of hypovolemia, the anesthesiologist often has to deal with normovolemic anemia. The clinical relevance of this isolated decrease in hemoglobin concentration consists in an eventually compromised global or regional oxygen supply with the development of tissue hypoxia below a critical threshold. This is an individual threshold for each patient and depends on his or her capacity to compensate the decrease in blood oxygen content. Therefore, physiologic transfusion triggers should primarily be applied and not rigid numeric transfusion triggers, such as hemoglobin concentration, which do not take into account each patient's individual reserve.
Collapse
Affiliation(s)
- C. Madjdpour
- Institut für Anästhesiologie, Universitätsspital Lausanne (CHUV), Schweiz
| | - C. Marcucci
- Institut für Anästhesiologie, Universitätsspital Lausanne (CHUV), Schweiz
| | - J.-D. Tissot
- Unité de Médecine Transfusionelle, Universitätsspital Lausanne (CHUV), Schweiz
| | - D. R. Spahn
- Institut für Anästhesiologie, Universitätsspital Lausanne (CHUV), Schweiz
- Institut für Anästhesiologie, Universitätsspital Lausanne (CHUV), CH-1011 Lausanne
| |
Collapse
|
14
|
Abstract
Careful assessment of risks and benefits has to precede each decision on allogeneic red blood cell (RBC) transfusion. Currently, a number of key issues in transfusion medicine are highly controversial, most importantly the influence of different transfusion thresholds on clinical outcome. The aim of this article is to review current evidence on blood transfusions, to highlight 'hot topics' with respect to efficacy, outcome and risks, and to provide the reader with transfusion guidelines. In addition, a brief synopsis of transfusion alternatives will be given. Based on up-to-date information of current evidence, together with clinical knowledge and experience, the physician will be able to make transfusion decisions that bear the lowest risk for the patient.
Collapse
Affiliation(s)
- C Madjdpour
- Department of Anaesthesiology, University Hospital Lausanne, Switzerland
| | | |
Collapse
|
15
|
Madjdpour C, Bacic D, Kaissling B, Murer H, Biber J. Segment-specific expression of sodium-phosphate cotransporters NaPi-IIa and -IIc and interacting proteins in mouse renal proximal tubules. Pflugers Arch 2004; 448:402-10. [PMID: 15007650 DOI: 10.1007/s00424-004-1253-x] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2004] [Accepted: 02/10/2004] [Indexed: 10/26/2022]
Abstract
Sodium-dependent phosphate cotransport in renal proximal tubules (PTs) is heterogeneous with respect to proximal tubular segmentation (S1 vs. S3) and nephron generation (superficial vs. juxtamedullary). In the present study, S1 and S3 segments of superficial and juxtamedullary nephrons were laser-microdissected and mRNA and protein expression of the Na/Pi-cotransporters NaPi-IIa and NaPi-IIc and the PDZ proteins NHERF-1 and PDZK1 determined. Expression of NaPi-IIa mRNA decreased axially in juxtamedullary nephrons. There was no effect of dietary Pi content on NaPi-lla mRNA expression in any proximal tubular segment. The abundance of the NaPi-IIa cotransporter in the brush-border membrane showed inter- and intranephron heterogeneity and increased in response to a low-Pi diet (5 days), suggesting that up-regulation of NaPi-lla occurs via post-transcriptional mechanisms. In contrast, NaPi-IIc mRNA and protein was up-regulated by the low-Pi diet in all nephron generations analysed. NHERF-1 and PDZK1, at both mRNA and protein levels, were distributed evenly along the PTs and did not change after a low-Pi diet.
Collapse
Affiliation(s)
- C Madjdpour
- Institute of Anatomy, University of Zurich, 8057, Zurich, Switzerland
| | | | | | | | | |
Collapse
|
16
|
Madjdpour C, Jewell UR, Kneller S, Ziegler U, Schwendener R, Booy C, Kläusli L, Pasch T, Schimmer RC, Beck-Schimmer B. Decreased alveolar oxygen induces lung inflammation. Am J Physiol Lung Cell Mol Physiol 2003; 284:L360-7. [PMID: 12388372 DOI: 10.1152/ajplung.00158.2002] [Citation(s) in RCA: 139] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Molecular mechanisms of the inflammatory reaction in hypoxia-induced lung injury are not well defined. Therefore, effects of alveolar hypoxia were studied in rat lungs, exposing rats to 10% oxygen over periods of 1, 2, 4, 6, and 8 h. An increase in the number of macrophages in bronchoalveolar lavage fluid of hypoxic animals was shown between 1 and 8 h. Extravasation of albumin was enhanced after 1 h and remained increased throughout the study period. NF-kappaB-binding activity as well as mRNA for TNF-alpha, macrophage inflammatory protein (MIP)-1beta, and monocyte chemoattractant protein (MCP)-1 were increased within the first 2 h of exposure to hypoxia. Hypoxia-inducible factor (HIF)-1alpha and intercellular adhesion molecule (ICAM)-1 mRNA were upregulated between 1 and 6 h. Elimination of alveolar macrophages by intratracheal application of liposome-encapsulated clodronate led to a decreased expression of NF-kappaB binding activity, HIF-1alpha, TNF-alpha, ICAM-1, and MIP-1beta. In summary, alveolar hypoxia induced macrophage recruitment, an increase in albumin leakage, and enhanced expression of inflammatory mediators, which were mainly macrophage dependent. Alveolar macrophages appear to have a prominent role in the inflammatory response in hypoxia-induced lung injury and the related upregulation of inflammatory mediators.
Collapse
Affiliation(s)
- C Madjdpour
- Institute of Physiology, Department of Surgery, University of Zurich, Winterthurerstrasse 190, CH-8057 Zurich, Switzerland
| | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Beck-Schimmer B, Madjdpour C, Kneller S, Ziegler U, Pasch T, Wüthrich RP, Ward PA, Schimmer RC. Role of alveolar epithelial ICAM-1 in lipopolysaccharide-induced lung inflammation. Eur Respir J 2002; 19:1142-50. [PMID: 12108870 DOI: 10.1183/09031936.02.00236602] [Citation(s) in RCA: 60] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Intercellular adhesion molecule-1 (ICAM-1) is known to play a central role in lung inflammation. Limited information, however, is available regarding the expression and biological function of ICAM-1 in the alveolar epithelial compartment. The current report analyses the expression pattern of ICAM-1 in primary cultures of rat alveolar epithelial cells (AECs) and in the rat lung following instillation of bacterial endotoxin (lipopolysaccharide (LPS)) in order to better define the role of alveolar epithelial ICAM-1. AECs stimulated in vitro with LPS were evaluated for ICAM-1 and ICAM-1 messenger ribonucleic acid content. Adherence assays with neutrophils and macrophages were performed. Endotoxin-induced ICAM-1 upregulation on AECs was demonstrated in vivo by immunofluorescence staining. In addition, the effect of intratracheally-instilled anti-ICAM-1 was assessed. Significant upregulation of ICAM-1 occurred in vitro and in vivo on AECs after LPS stimulation. Adherence assays showed a 114% increase in adhesion of neutrophils to AECs. Antibody directed against ICAM-1 reduced this adhesion by 40%. A significant reduction in the number of neutrophils in bronchoalveolar lavage fluid and whole lung was seen under airway ICAM-1 blockade. These data indicate that intercellular adhesion molecule-1 participates in the inflammatory response to lipopolysaccharide-induced lung injury in the distal airways by interacting mainly with neutrophils.
Collapse
Affiliation(s)
- B Beck-Schimmer
- Institute of Anaesthesiology, University of Zurich Medical School, Switzerland.
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Beck-Schimmer B, Schimmer RC, Madjdpour C, Bonvini JM, Pasch T, Ward PA. Hypoxia mediates increased neutrophil and macrophage adhesiveness to alveolar epithelial cells. Am J Respir Cell Mol Biol 2001; 25:780-7. [PMID: 11726405 DOI: 10.1165/ajrcmb.25.6.4433] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Leukocyte infiltration is known to play an important role in hypoxia-induced tissue damage. There is a paucity of information on the role of hypoxia in the expression of adhesion molecules on respiratory epithelial cells. The current studies focus on the adhesion molecules intercellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1), their expression pattern on alveolar epithelial cells, and their biologic function under hypoxic conditions. Rat alveolar epithelial cells (AEC) were exposed to hypoxia for several time periods. With 5% oxygen, mRNA for ICAM-1 and VCAM-1 rose by 100%, peaking between 0.5 and 1 h. ICAM-1 and VCAM-1 protein showed an increase between 2 and 4 h. Neutrophil adherence to hypoxia-exposed AEC was enhanced by 115%. This increase was reduced by 83% with anti-ICAM-1 antibody. Adherence of alveolar macrophages to AEC increased by 118% and could be blocked by 95% with anti-VCAM-1 antibody. The present study shows for the first time an early increase of ICAM-1 and VCAM-1 expression on rat AEC under hypoxic conditions. These adhesion molecules are involved in increased adhesiveness of neutrophils and macrophages. Such responses might play an important role in the adhesion of leukocytes and macrophages to lung epithelial cells during hypoxic conditions.
Collapse
Affiliation(s)
- B Beck-Schimmer
- Institutes of Anesthesiology and Physiology, University of Zurich, Zurich, Switzerland.
| | | | | | | | | | | |
Collapse
|
19
|
Madjdpour C, Oertli B, Ziegler U, Bonvini JM, Pasch T, Beck-Schimmer B. Lipopolysaccharide induces functional ICAM-1 expression in rat alveolar epithelial cells in vitro. Am J Physiol Lung Cell Mol Physiol 2000; 278:L572-9. [PMID: 10710530 DOI: 10.1152/ajplung.2000.278.3.l572] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Lipopolysaccharide (LPS)-induced lung inflammation is known to increase pulmonary intercellular adhesion molecule-1 (ICAM-1) expression. In the present study, L2 cells, a cell line of alveolar epithelial cells, were stimulated with LPS, and ICAM-1 expression was studied. ICAM-1 protein on L2 cells peaked at 6 (38% increase; P < 0.01) and 10 (48% increase; P < 0.001) h after stimulation with Escherichia coli and Pseudomonas aeruginosa LPS, respectively. ICAM-1 mRNA expression was markedly increased, with a peak at 2-4 (E. coli) and 4-6 (P. aeruginosa) h. Adherence assays of neutrophils to LPS-stimulated L2 cells showed a threefold increase in adherence (P < 0.001). Pretreatment of the neutrophils with anti-lymphocyte function-associated antigen-1 and anti-Mac-1 antibodies reduced adherence by 54% (P < 0.001). Analysis of immunofluorescence staining for ICAM-1 showed an exclusive apical expression of ICAM-1. These results indicate that LPS upregulates functional active ICAM-1 on the apical part of the membrane in rat pneumocytes.
Collapse
Affiliation(s)
- C Madjdpour
- Institute of Anesthesiology, University of Zurich, 8091 Zurich, Switzerland
| | | | | | | | | | | |
Collapse
|