1
|
Bogni A, Laera L, Cucchi C, Iwata R, Seregni E, Pascali C. An improved automated one-pot synthesis of O-(2-[18F]fluoroethyl)-L-tyrosine ([18F]FET) based on a purification by cartridges. Nucl Med Biol 2019; 72-73:11-19. [DOI: 10.1016/j.nucmedbio.2019.05.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 05/09/2019] [Accepted: 05/14/2019] [Indexed: 10/26/2022]
|
2
|
Crippa F, Agresti R, Donne VD, Pascali C, Bogni A, Chiesa C, De Sanctis V, Schiavini M, Decise D, Bombardieri E. The Contribution of Positron Emission Tomography (Pet) with 18F-Fluorodeoxyglucose (Fdg) in the Preoperative Detection of Axillary Metastases of Breast Cancer: The Experience of the National Cancer Institute of Milan. Tumori 2018; 83:542-3. [PMID: 9226015 DOI: 10.1177/030089169708300211] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- F Crippa
- Nuclear Medicine Division, National Cancer Institute, Milan, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Crippa F, Gavazzi C, Bozzetti F, Chiesa C, Pascali C, Bogni A, De Sanctis V, Decise D, Schiavini M, Cucchetti G, Bombardieri E. The Influence of Blood Glucose Levels on [18F]Fluorodeoxyglucose (Fdg) Uptake in Cancer: A Pet Study in Liver Metastases from Colorectal Carcinomas. Tumori 2018; 83:748-52. [PMID: 9349315 DOI: 10.1177/030089169708300407] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Aims and background To study the influence of blood glucose levels on the clinical reliability of positron emission tomography (PET) with [18F]-2-fluoro-2-deoxy-D-glucose (FDG) in the detection of liver metastases from colorectal carcinomas and in the analysis of tumor uptake of FDG. Methods After having given their informed consent, 8 patients with 20 liver metastases (mean size, 31.5 mm; range, 10–75 mm) detected by means of CT were submitted to a first FDG-PET examination under fasting conditions and, 2 days later, to a second FDG-PET examination performed after iv infusion of a glucose solution (4 mg/kg/min for 2 hrs). The results of the two studies were compared in each patient, considering both the localization of the metastases and the FDG uptake in the lesions. A non-kinetic method was used, calculating the Standardized Uptake Value (SUV). Results All 20 metastases were clearly visible on FDG-PET under fasting conditions. Moreover, in 2 patients FDG-PET detected a number of unknown liver metastases. The blood glucose levels after glucose infusion were significantly higher than the levels under fasting conditions, 158 ± 13.8 mg/100 ml (mean ± sd) and 92.4 ± 10.2, respectively (P « 0.001), and the quality of the FDG-PET images showed a marked deterioration. FDG-PET was unable to detect 6 of the 20 lesions and another 10 lesions were localized less clearly. Moreover, 80% of the unknown liver metastases were not detected after glucose loading. The SUVs of metastases decreased from 9.4 ± 5.7 (mean ± sd) under fasting conditions to 4.3 ± 8.3 after glucose loading (P « 0.001). Conclusions FDG-PET studies may be particularly unreliable under conditions of high levels of blood glucose. Therefore, patients entering FDG-PET studies should fast, and blood glucose concentration needs to be taken into account when evaluating FDG uptakes in follow-up studies.
Collapse
Affiliation(s)
- F Crippa
- PET Unit, National Cancer Institute, Milan, Italy
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Seregni E, Maccauro M, Chiesa C, Mariani L, Pascali C, Mazzaferro V, De Braud F, Buzzoni R, Milione M, Lorenzoni A, Bogni A, Coliva A, Vullo SL, Bombardieri E. Treatment with tandem [90Y]DOTA-TATE and [177Lu]DOTA-TATE of neuroendocrine tumours refractory to conventional therapy. Eur J Nucl Med Mol Imaging 2013; 41:223-30. [DOI: 10.1007/s00259-013-2578-5] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2013] [Accepted: 09/12/2013] [Indexed: 11/28/2022]
|
5
|
Bombardieri E, Crippa F, Maffioli L, Chiti A, Castellani M, Greco M, Agresti R, Bogni A, Chiesa C, Desanctis V, Massaron S, Pascali C. Axillary lymph node metastases detection with nuclear medicine approaches in patients with newly diagnosed breast cancer. Int J Oncol 2012; 8:693-9. [PMID: 21544415 DOI: 10.3892/ijo.8.4.693] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Three different tracers, Tc-99m-Sesta MIBI, In-111-Pentetreotide and F-18-FDG, were evaluated in a preliminary study in three different groups of 10 breast cancer patients programmed for breast cancer resection and axillary dissection. Planar scintigraphy and single photon emission tomography (SPET) technique were used for imaging with Tc-99m-Sesta-MIBI and In-111-Pentetreotide, positron emission tomography (PET) was used for imaging with F-18-FDG. We studied 30 breast cancer patients; their clinical stage according to the TNM classification was 30 T1-T2, 1 T4 and 1 Tx (one patient had bilateral cancer and one had bifocal cancer). The lymph nodal status ranged from NO to N2 (14 NO, 16 N1, 1 N2). Tc-99m-Sesta MIBI, In-111 Pentetreotide SPET and F-18-FDG PET were randomly performed before surgery to visualize the primary tumors and to detect axillary lymph node invasion. Tc-99m-Sesta MIBI correctly visualized 10 out of 11 primary cancers in 10 patients. In-111-Pentetreotide detected 9 out of 10 primary cancers. F-18-FDG imaged all the tumors (10). As regards the axillary nodes, Tc-99m-MIBI excluded axilla involvement in 7 out of 7 negative axillae (N-), while it was positive in 2 out of 3 positive cases (N+); In-111-Pentetreotide correctly identified 7 out of 8 negative axillae (N-), while it detected 2 of 3 positive sites. F-18-FDG visualized all positive axillary lymph nodes (4 out of 4 N+ patients) and correctly excluded involvement in all negative patients (6 out of 6 N- cases). This study demonstrated that all three tracers are adequate to be proposed as tumor seeking agents with the aim of developing non-invasive diagnostic methods for pre-operative detection of axillary metastases, so that surgical dissection can be limited to selected patients. The authors discuss the advantages and disadvantages of the different radiopharmaceuticals and conclude that in centers with PET facilities F-18-FDG is the best tumor seeking agent for the evaluation of axillary status. Between Tc-99m-Sesta MIBI and In-111-Pentetreotide the former seems to present more advantages in this kind of application, considering also its lower cost and easier availability. These results encourage further study, including the simultaneous comparison of these tracers in breast cancer staging.
Collapse
Affiliation(s)
- E Bombardieri
- IST NAZL TUMORI,DEPT SURG ONCOL B,I-20133 MILAN,ITALY
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Pascali C, Bogni A, Cucchi C, Laera L, Crispu O, Maiocchi G, Crippa F, Bombardieri E. Detection of additional impurities in the UV-chromatogram of l-[S-methyl-11C]methionine. J Radioanal Nucl Chem 2011. [DOI: 10.1007/s10967-011-0995-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
7
|
Bogni A, Crispu O, Fugazza L, Cucchi C, Laera L, Iwata R, Crippa F, Bombardieri E, Pascali C. [N-Methyl-11C]choline by on-column reaction: a study on [11C]CH3I incorporation and the residual amount of precursor in the product. J Labelled Comp Radiopharm 2010. [DOI: 10.1002/jlcr.1838] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
8
|
Iwata R, Pascali C, Bogni A, Yanai K, Kato M, Ido T, Ishiwata K. A combined loop-SPE method for the automated preparation of [11C]doxepin. J Labelled Comp Radiopharm 2002. [DOI: 10.1002/jlcr.557] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
9
|
Iwata R, Pascali C, Bogni A, Miyake Y, Yanai K, Ido T. A simple loop method for the automated preparation of (11C)raclopride from (11C)methyl triflate. Appl Radiat Isot 2001; 55:17-22. [PMID: 11339532 DOI: 10.1016/s0969-8043(00)00368-7] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A simple automated preparation of [11C]raclopride by reaction of [11C]methyl triflate with demethylraclopride triflate is described. The conventional bubbling of [11C]methyl triflate into the precursor solution was compared with two alternative methods which used a commercially available C18 cartridge (on-column method) or an empty PTFE tube (loop method) as support for the precursor solution. The influence of several solvents was assessed for all three methods. The on-column method showed excellent trapping efficiencies of [11C]methyl triflate but gave the lowest radiochemical yields. The loop method proved to be a simplified alternative to the bubbling method, giving comparable radiochemical yields with less precursor and offering an easy way to transfer the reaction mixture into an HPLC column. By the simple-loop method [11C]raclopride could be prepared in over 40% radiochemical yields (decay-corrected and based on [11C]methyl triflate).
Collapse
Affiliation(s)
- R Iwata
- Graduate School of Engineering, Tohoku University, Sendai, Japan.
| | | | | | | | | | | |
Collapse
|
10
|
Iwata R, Pascali C, Bogni A, Yanai K, Kato M, Ido T, Ishiwata K. Preparation of [11C]doxepin from [11C]methyl triflate by loop method: Effect of specific activity on [11C]methylation. J Labelled Comp Radiopharm 2001. [DOI: 10.1002/jlcr.25804401347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
11
|
Iwata R, Pascali C, Bogni A, Horvath G, Kovacs Z, Yanai K, Ido T. A new, convenient method for the preparation of 4-[18F]fluorobenzyl halides. Appl Radiat Isot 2000; 52:87-92. [PMID: 10670927 DOI: 10.1016/s0969-8043(99)00117-7] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
A convenient method suitable for automated preparation of 4-[18F]fluorobenzyl halides from no-carrier-added [18F]fluoride has been developed. 4-[18F]Fluorobenzaldehyde, synthesized from [18F]fluoride by aromatic nucleophilic substitution on 4-trimethylammoniumbenzaldehyde triflate, was first retained on a C18 cartridge and there efficiently reduced to 4-[18F]fluorobenzyl alcohol simply by flowing an aqueous solution of NaBH4. The conversion of 4-[18F]fluorobenzyl alcohol to 4-[18F]fluorobenzyl halide was investigated using PBr3, PI3, P2I4, Ph3PBr2 and Ph3PI2 in CH2Cl2. 4-[18F]Fluorobenzyl halides were purified by passing through a disposable silica cartridge. The conversion rapidly proceeded in radiochemical yields of nearly 90% at 40 degrees C with P2I4 and almost quantitatively at room temperature with Ph3PBr2. With this last reagent 4-[18F]fluorobenzyl bromide was obtained in overall radiochemical yields of 50-60% within 30 min from EOB.
Collapse
Affiliation(s)
- R Iwata
- CYRIC Tohoku University, Sendai, Japan.
| | | | | | | | | | | | | |
Collapse
|
12
|
Crippa F, Seregni E, Agresti R, Chiesa C, Pascali C, Bogni A, Decise D, De Sanctis V, Greco M, Daidone MG, Bombardieri E. Association between [18F]fluorodeoxyglucose uptake and postoperative histopathology, hormone receptor status, thymidine labelling index and p53 in primary breast cancer: a preliminary observation. Eur J Nucl Med 1998; 25:1429-34. [PMID: 9818284 DOI: 10.1007/s002590050319] [Citation(s) in RCA: 143] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
To investigate the possible role of positron emission tomography (PET) with fluorine-18 fluorodeoxyglucose (FDG) in the prognostic evaluation of primary breast cancer, we studied 86 patients with T1-3 (TNM classification) breast tumours before surgery and compared the tumour FDG uptake, calculated as a standardized uptake value (SUV), with postoperative histopathological findings, steroid hormone receptor status of the tumour, thymidine labelling index (LI) and tissular expression of p53. SUV was significantly higher in infiltrating ductal carcinomas (n = 68; median SUV = 5.6) than in lobular ones (n = 18; median SUV = 3.8), and in grade 3 carcinomas (n = 26; median SUV = 6.2) than in grade 1-2 ones (n = 60; median SUV = 4.9). Moreover, SUV was significantly higher in carcinomas with high levels of p53 (n = 12; median SUV = 9.5) than in those with low levels (n = 48; median SUV = 4.25). By contrast, there was no significant correlation between SUV and the steroid hormone receptor status or LI of tumours. Our data demonstrate that FDG uptake, expressed as SUV, is associated with certain prognostic factors in breast cancer, such as histopathological grading and p53 expression, which can be assessed only by means of postoperative in vitro examinations. Hence, the information provided by FDG-PET is to some extent related to relevant information on tumour biology. The clinical value of these data will have to be confirmed by analysis of the independence of SUV from other prognostic factors by means of a multivariate analysis performed on a larger series of patients with adequate follow-up. If SUV is confirmed as an independent variable, FDG-PET could assume an important role in the determination of appropriate therapeutic strategies for primary breast cancer.
Collapse
Affiliation(s)
- F Crippa
- PET Unit, Division of Nuclear Medicine, National Cancer Institute, Milan, Italy
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Pascali C, Bogni A, Decise D, Remonti F, De Sanctis V, Chiesa C, Crippa F, Schiavini M, Cucchetti G, Bombardieri E. A simple and semi-automated system for increasing the recovery of aqueous [18F] fluoride from target. Anticancer Res 1998; 18:1563-7. [PMID: 9673371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
A simple semi-automated apparatus is described for rinsing the transport line from the [18F] fluoride. target to the hot-cell after recovery of aqueous [18F] fluoride. The additional activity thus recovered can then be added to that previously trapped on Dowex 1X8 (CO3=) or, alternatively, diverted to a second vial for other uses such as research, PET-camera calibration or bone investigations by PET. Inclusion of the target chamber in the rinsing procedure increased the additional recovery of activity up to ca. 15%, without a noticeable effect on the isotopic integrity of the recovered [18O]H2O.
Collapse
Affiliation(s)
- C Pascali
- National Cancer Institute, Department of Nuclear Medicine, Milan, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Bogni A, Pascali C, Iwata R, Cavalleri A, de Sanctis V, Decise D, Cucchetti G, Crippa F, Chiesa C, Schiavini M, Schiavini M, Bombardieri E. [18F]FDG synthesis by Anatech RB-86 robotic system: Improvements and general considerations. J Radioanal Nucl Chem 1998. [DOI: 10.1007/bf02387445] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
15
|
Crippa F, Agresti R, Seregni E, Greco M, Pascali C, Bogni A, Chiesa C, De Sanctis V, Delledonne V, Salvadori B, Leutner M, Bombardieri E. Prospective evaluation of fluorine-18-FDG PET in presurgical staging of the axilla in breast cancer. J Nucl Med 1998; 39:4-8. [PMID: 9443729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
METHODS The presurgical, noninvasive staging of axillary nodes for metastases was prospectively investigated in 68 patients who were diagnosed with primary breast cancer using PET with 18F-fluorodeoxyglucose (FDG). Four patients had bilateral nodules; therefore, the total number of evaluable cases was 72. Visual analyses of attenuation-corrected PET images and standardized uptake values (SUVs) of FDG uptake in carcinomas were compared with histopathological surgical findings. The SUV distribution differences between carcinomas with and without axillary metastases were evaluated by means of statistical and receiver operating characteristics analyses. RESULTS PET correctly classified 64 of the 72 cases; four false-positive and four false-negative PET results were found. The overall sensitivity, specificity and accuracy of PET for axillary metastases were 85%, 91% and 89%, respectively. With respect to the clinical axillary stage of the patients (TNM, or tumor-node-metastasis, classification), we obtained the following results: N0 patients, sensitivity = 70%, specificity = 92%, accuracy = 86%; N1a patients, sensitivity = 85.5%, specificity = 100%, accuracy = 95%; and N1b-2 patients, sensitivity = 100%, specificity = 67%, accuracy = 87%. The median SUV in carcinomas with axillary metastases (4.6) was significantly higher than that in carcinomas without metastases (2.9), but there was a great SUV overlap between the two groups (interquartile ranges = 2.7-7.2 and 1.9-4.5, respectively). Analysis of the receiver operating characteristics curve showed that a high sensitivity of SUV in predicting axillary metastases was associated with a very low specificity and vice versa. With the best SUV cutoff value of 2.9, the sensitivity and specificity were 74% and 56%, respectively. CONCLUSION PET showed good overall diagnostic accuracy in the detection of axillary metastases (86%). The very high accuracy (95%) in N1a patients is of particular importance. False-negative PET findings, however, can be encountered. SUVs of breast carcinoma cannot predict the spread of the disease to the axilla, even if higher values are often associated with axillary metastases. Any decision on the use of PET in the presurgical staging of breast cancer should be incorporated into a more general debate on axillary management. In selected patients with a very low probability of axillary metastases (T1a), in whom axillary surgery can already be avoided according to data from follow-up studies, 18F-FDG PET could be proposed as a noninvasive imaging modality to improve the diagnosis of axillary relapses.
Collapse
Affiliation(s)
- F Crippa
- Division of Nuclear Medicine, National Cancer Institute, Milan, Italy
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Chiesa C, De Sanctis V, Crippa F, Schiavini M, Fraigola CE, Bogni A, Pascali C, Decise D, Marchesini R, Bombardieri E. Radiation dose to technicians per nuclear medicine procedure: comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose. Eur J Nucl Med 1997; 24:1380-9. [PMID: 9371871 DOI: 10.1007/s002590050164] [Citation(s) in RCA: 90] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The aim of this study was to determine the non-extremity gamma dose received by a technician while performing an ordinary nuclear medicine procedure or a static (i.e. without blood sampling) fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) study. The dose per patient was measured by means of a commercial electronic pocket Geiger Mueller dosimeter, worn in the upper left pocket of the overalls. This was previously tested by exposure to known point sources of technetium-99m, gallium-67, iodine-131 and fluorine-18 in the air. A further test was performed with 99mTc, 131I and 18F sources inserted in a water phantom to simulate the condition of high scattering degradation of the primary radiation due to the patient's tissues. Subsequently, the dose was measured by two technicians for a total of 314 clinical cases, covering the most common nuclear medicine procedures, including 44 static, two-level FDG PET studies with repositioning of the patient on the couch between the transmission and the emission scan and seven whole-body PET studies. The dose read by the dosimeter was corrected for environmental background and for detector efficiency measured with sources in the air. For a limited subset of cases, the time spent close to patients was also measured. Doses were then estimated by a crude non-absorbing point source approximation and by using experimental dose rates. A comparison between experimental and estimated doses, as well as with previously published data, completed the work. For most of the conventional procedures, the measured dose per procedure proved to be within the range 0.2-0.4 microSv, except for equilibrium angiocardioscintigraphy (1.0+/-0.5 microSv) and 99mTc-sestamibi single-photon emission tomography (1. 7+/-1.0 microSv). Comparison with data published in the last 20 years shows that our values are generally lower. The current more favourable working conditions are a result of technological improvements (for instance two-head gamma cameras capable of whole-body studies), and safer shielding and distance from patients. Two-level PET gave 11.5+/-4.4 microSv and whole-body PET 5.9+/-1.2 microSv. In a subset of patients these values could be subdivided into the separate contributions from each phase of the procedure. They were: 0.11+/-0.04 microSv for daily quality assurance, 2.9+/-3.0 microSv for two transmission scans, 0.3+/-0.1 microSv for syringe preparation, 2.8+/-1.8 microSv for injection and escorting the patient to the waiting room, 1.7+/-1.5 microSv for a whole-body emission scan, 7.7+/-5.2 microSv for two emission scans, and 0.8+/-0. 2 microSv for patient departure. The higher value from PET by comparison with conventional procedures is attributable to the higher specific gamma constant of 18F, as well as the longer time required for accurate positioning.
Collapse
Affiliation(s)
- C Chiesa
- Unita' PET, Divisione Medicina Nucleare, Istituto Nazionale Tumori, Milano, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Botti C, Negri DR, Seregni E, Ramakrishna V, Arienti F, Maffioli L, Lombardo C, Bogni A, Pascali C, Crippa F, Massaron S, Remonti F, Nerini-Molteni S, Canevari S, Bombardieri E. Comparison of three different methods for radiolabelling human activated T lymphocytes. Eur J Nucl Med 1997; 24:497-504. [PMID: 9142729 DOI: 10.1007/bf01267680] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
One approach in the treatment of ovarian cancer patients involves the infusion of autologous T lymphocytes coupled with a bispecific monoclonal antibody MOv18/anti-CD3 (biMAb OC/TR), which recognizes a 38-kDa glycoprotein expressed on ovarian carcinomas and the CD3 T cell receptor. However, little is known about the in vivo biodistribution of injected activated lymphocytes, information that could be obtained by scintigraphic imaging of radiolabelled T cells in order to visualize the migratory pattern. We compared the efficiency, stability and toxicity of technetium-99m hexamethylpropylene amine oxime (HMPAO), indium-111 oxine and fluorine-18 2-fluoro-2-deoxy-d-glucose (FDG) in radiolabelling activated lymphocytes targeted with biMAb OC/TR. The mean labelling efficiencies of 111In-oxine and 18F-FDG using 2.5x10(8) lymphocytes (68% and 64%, respectively) were more than twice that of 99mTc-HMPAO (31%). Retention of the radionuclide in the cell was highest in the case of 111In-oxine labelling (less than 25% of the initial cell-bound activity released after 240 min, as compared with 44% of the 99mTc label in the same period and 45% of 18F radionuclide released after 150 min). None of the three radiolabelling reagents induced any significant alteration in cell viability or immunophenotype. However, both 111In-oxine and 18F-FDG induced a loss of cytotoxic activity of lymphocytes against the ovarian carcinoma cell line IGROV1, and all three radiolabelling reagents caused a significant reduction in the proliferative ability of labelled lymphocytes compared to controls, with cell death occurring after 8-9 days. Radiolabelling with the more stable 111In-oxine reagent using a higher number of lymphocytes (1.4x10(9)) but the same total activity (around 55.5 MBq) resulted in improved labelled T cell viability and proliferative ability, although the mean labelling efficiency decreased (35.8%). Together the data suggest that 111In-oxine at low activity per cell is the most appropriate reagent for radiolabelling activated retargeted T lymphocytes useful for in vivo biodistribution studies.
Collapse
Affiliation(s)
- C Botti
- Nuclear Medicine Department, National Cancer Institute, Milano, Italy
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Hume SP, Lammertsma AA, Bench CJ, Pike VW, Pascali C, Cremer JE, Dolan RJ. Evaluation of S-[11C]citalopram as a radioligand for in vivo labelling of 5-hydroxytryptamine uptake sites. Int J Rad Appl Instrum B 1992; 19:851-5. [PMID: 1428913 DOI: 10.1016/0883-2897(92)90171-t] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The biologically active S-enantiomer of [N-methyl-11C]citalopram was evaluated as a radioligand for in vivo labelling of the 5-hydroxytryptamine uptake site in brain, using ex vivo tissue counting in rats and positron emission tomography in man. In rats, the maximal signal for total versus non-specific binding was approx. 2 at 60-120 min after radioligand injection. Subsequent studies in man failed to identify a specific signal over a 90 min scanning period, due to prolonged retention of non-specific label.
Collapse
Affiliation(s)
- S P Hume
- MRC Cyclotron Unit, Hammersmith Hospital, London, England
| | | | | | | | | | | | | |
Collapse
|
19
|
Iwata R, Pascali C, Yuasa M, Yanai K, Takahashi T, Ido T. On-line [11C]methylation using [11C]methyl iodide for the automated preparation of 11C-radiopharmaceuticals. Int J Rad Appl Instrum A 1992; 43:1083-8. [PMID: 1330987 DOI: 10.1016/0883-2889(92)90048-j] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
A novel method for the efficient preparation of 11C-radiopharmaceuticals by on-line [11C]methylation using [11C]methyl iodide has been developed and applied to a rapid, convenient automated system. [11C]Methyl iodide is first trapped in a short column, containing an adsorber and coated substrate, which is connected to an HPLC injector. DMF is then introduced. Alternatively the substrate is added with the DMF. A whole reaction mixture can be easily injected onto an HPLC column for purification by switching the injector valve immediately after the reaction. Thus, radiochemical yields in the preparation of 11C-labeled doxepin, benztropine, cyproheptadine and N-methylspiperone have been improved remarkably and the synthetic procedure simplified.
Collapse
Affiliation(s)
- R Iwata
- CYRIC Tohoku University, Sendai, Japan
| | | | | | | | | | | |
Collapse
|
20
|
Hume SP, Pascali C, Pike VW, Turton DR, Ahier RG, Myers R, Bateman DM, Cremer JE, Manjil LG, Dolan R. Citalopram: labelling with carbon-11 and evaluation in rat as a potential radioligand for in vivo PET studies of 5-HT re-uptake sites. Int J Rad Appl Instrum B 1991; 18:339-51. [PMID: 1676995 DOI: 10.1016/0883-2897(91)90130-d] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
In vivo autoradiography of [N-methyl-3H]citalopram in rat brain shows a differential regional localization which correlates with the localization of 5-HT re-uptake binding sites defined in vitro. A comparison of the biodistribution of [N-methyl-3H]citalopram over 2 h after i.v. injection in (1) control rats (2) rats pre-dosed with either citalopram or paroxetine and (3) rats chemically-lesioned with p-chloroamphetamine provides an estimate of specific binding relative to total binding in vivo. The ratio of binding in certain regions (e.g. cingulate) to binding in a reference tissue (e.g. cerebellum) at 30-120 min post injection is c. 1.4. In view of these results a method was developed for labelling citalopram with carbon-11 (t1/2 = 20.3 min, beta + = 99.8%) to provide a potential radioligand for studies using positron emission tomography. Thus, reaction of nca [11C]iodomethane, prepared from cyclotron-produced [11C]carbon dioxide, with norcitalopram in ethanol containing 2,2,6,6-tetramethyl-piperidine for 5 min at 95 degrees C gives crude [N-methyl-11C]citalopram in 60% radiochemical yield, decay-corrected. HPLC on silica gel provides radiochemically and chemically pure [N-methyl-11C]citalopram, as assessed by TLC, HPLC and MS. This product (isolated radiochemical yield, 49%) is easily formulated for i.v. injection. Up to 2 GBq of formulated product with a specific activity of c. 15 GBq/mumol have been prepared within 40 min from the end of radionuclide production. The described radiosynthesis has also been applied to give the single biologically active (+)-enantiomer of [N-methyl-11C]citalopram rather than the racemate. This product gives enhanced specific signal in the rat following i.v. injection, the ratio of uptake in regions of interest relative to cerebellum approaching 2 at 90 min.
Collapse
Affiliation(s)
- S P Hume
- MRC Cyclotron Unit, Hammersmith Hospital, London, England
| | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Price GW, Ahier RG, Hume SP, Myers R, Manjil L, Cremer JE, Luthra SK, Pascali C, Pike V, Frackowiak RS. In vivo binding to peripheral benzodiazepine binding sites in lesioned rat brain: comparison between [3H]PK11195 and [18F]PK14105 as markers for neuronal damage. J Neurochem 1990; 55:175-85. [PMID: 2355218 DOI: 10.1111/j.1471-4159.1990.tb08836.x] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Peripheral-type benzodiazepine binding sites are not normally present in most cerebral tissues, but following neuronal damage, the cells involved in the ensuing gliosis show a marked expression of these sites. In a unilateral excitotoxic striatal lesion in the rat, we sought to determine whether the isoquinoline derivatives PK11195 and PK14105 bind to these sites in vivo and whether demonstration of these sites offers the potential of indirectly localising areas of neuronal damage. Binding was studied at several intervals after coinjection of [3H]PK11195 and [18F]PK14105 to determine the time courses of specific binding. Both compounds were rapidly extracted into all cerebral tissues, but in the absence of binding sites in nonlesioned tissues, this was followed by a rapid clearance of radioactivity. In lesioned areas, both [3H]PK11195 and [18F]PK14105 accumulated over the first 5 min followed by a much slower clearance of radioactivity, resulting in a "specific signal." [3H]PK11195 binding peaked at 20-30 min postinjection, with radioactivity in the lesioned striatum being three times greater than in its contralateral homologue. The specific signal was present for at least 60 min. The maximal [18 F]PK14105-specific signal was of similar magnitude but peaked earlier and was retained for only 45 min. Specific signals with both ligands were also detected in regions remote from the primary lesion site, e.g., in the hippocampus and substantia nigra. Predosing animals with a large dose of PK11195 (3 mg/kg), sufficient to saturate peripheral-type benzodiazepine binding sites, abolished in vivo binding of both [3H]PK11195 and [18F]PK14105 to both primary- and remote-lesioned tissues. The specific signal with both ligands could be of sufficient magnitude and duration to make tomographic studies in humans feasible.
Collapse
Affiliation(s)
- G W Price
- MRC Cyclotron Unit, Hammersmith Hospital, London, England
| | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Pascali C, Luthra SK, Pike VW, Price GW, Ahier RG, Hume SP, Myers R, Manjil L, Cremer JE. The radiosynthesis of [18F]PK 14105 as an alternative radioligand for peripheral type benzodiazepine binding sites. Int J Rad Appl Instrum A 1990; 41:477-82. [PMID: 2166014 DOI: 10.1016/0883-2889(90)90008-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
A method has been developed for labelling PK 14105 [N-methyl-N-(1-methyl-propyl)-1(2-fluoro-5-nitrophenyl)isoquinoline-3- carboxamide], a ligand that has high affinity and selectivity for peripheral type benzodiazepine binding sites (PBBS), with NCA fluorine-18 (t1/2 = 109.8 min, beta + = 96.9%). The method involves treating the 2-chloro-analogue with cyclotron-produced NCA [18F]fluoride in dimethyl sulphoxide, with rubidium carbonate as base, at 140 degrees C for 20 min. Purification is achieved by separation on a reverse phase Sep-Pak followed by PHLC on a silica gel column, to give chemically and radiochemically pure product with a specific activity of ca 7.4 GBq/mumol (200 mCi/mumol), decay-corrected to the end of radionuclide production (EOB). The radiosynthesis requires 210 min. giving a radiochemical yield of 10-20%, decay-corrected to EOB. [18F]PK 14105 was found to bind avidly to sites associated with kainic acid-induced unilateral lesions of rat striata. Such binding was blocked by pre-dosing the rat with PK 11195, so providing evidence for specific binding to PBBS. These results suggest that [18F]PK 14105 has potential for studying phenomena associated with PBBS in man by PET.
Collapse
Affiliation(s)
- C Pascali
- MRC Cyclotron Unit, Hammersmith Hospital, London, U.K
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Pascali C. [The role of aircraft in the epidemiology of plague]. Minerva Med 1982; 73:2083-8. [PMID: 7099464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|