1
|
Camerlingo N, Shaafi Kabiri N, Psaltos DJ, Kelly M, Wicker MK, Messina I, Auerbach SH, Zhang H, Messere A, Isik Karahanoglu F, Santamaria M, Demanuele C, Caouette D, Thomas KC. Monitoring Gait and Physical Activity of Elderly Frail Individuals in Free-Living Environment: A Feasibility Study. Gerontology 2023; 70:439-454. [PMID: 37984340 PMCID: PMC11014463 DOI: 10.1159/000535283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 11/11/2023] [Indexed: 11/22/2023] Open
Abstract
INTRODUCTION Frailty is conventionally diagnosed using clinical tests and self-reported assessments. However, digital health technologies (DHTs), such as wearable accelerometers, can capture physical activity and gait during daily life, enabling more objective assessments. In this study, we assess the feasibility of deploying DHTs in community-dwelling older individuals, and investigate the relationship between digital measurements of physical activity and gait in naturalistic environments and participants' frailty status, as measured by conventional assessments. METHODS Fried Frailty Score (FFS) was used to classify fifty healthy individuals as non-frail (FFS = 0, n/female = 21/11, mean ± SD age: 71.10 ± 3.59 years), pre-frail (FFS = 1-2, n/female = 23/9, age: 73.74 ± 5.52 years), or frail (FFS = 3+, n/female = 6/6, age: 70.70 ± 6.53 years). Participants wore wrist-worn and lumbar-worn GENEActiv accelerometers (Activinsights Ltd., Kimbolton, UK) during three in-laboratory visits, and at-home for 2 weeks, to measure physical activity and gait. After this period, they completed a comfort and usability questionnaire. Compliant days at-home were defined as follows: those with ≥18 h of wear time, for the wrist-worn accelerometer, and those with ≥1 detected walking bout, for the lumbar-worn accelerometer. For each at-home measurement, a group analysis was performed using a linear regression model followed by ANOVA, to investigate the effect of frailty on physical activity and gait. Correlation between at-home digital measurements and conventional in-laboratory assessments was also investigated. RESULTS Participants were highly compliant in wearing the accelerometers, as 94% indicated willingness to wear the wrist device, and 66% the lumbar device, for at least 1 week. Time spent in sedentary activity and time spent in moderate activity as measured from the wrist device, as well as average gait speed and its 95th percentile from the lumbar device were significantly different between frailty groups. Moderate correlations between digital measurements and self-reported physical activity were found. CONCLUSIONS This work highlights the feasibility of deploying DHTs in studies involving older individuals. The potential of digital measurements in distinguishing frailty phenotypes, while unobtrusively collecting unbiased data, thus minimizing participants' travels to sites, will be further assessed in a follow-up study.
Collapse
Affiliation(s)
- Nunzio Camerlingo
- Early Clinical Development, Pfizer, Inc., Cambridge, Massachusetts, USA
| | - Nina Shaafi Kabiri
- Chobanian and Avedisian School of Medicine, Boston University, Boston, Massachusetts, USA
| | | | - Meredith Kelly
- Chobanian and Avedisian School of Medicine, Boston University, Boston, Massachusetts, USA
| | - Madisen K Wicker
- Chobanian and Avedisian School of Medicine, Boston University, Boston, Massachusetts, USA
| | - Isabelle Messina
- Chobanian and Avedisian School of Medicine, Boston University, Boston, Massachusetts, USA
| | - Sanford H Auerbach
- Chobanian and Avedisian School of Medicine, Boston University, Boston, Massachusetts, USA
| | - Hao Zhang
- Early Clinical Development, Pfizer, Inc., Cambridge, Massachusetts, USA
| | - Andrew Messere
- Early Clinical Development, Pfizer, Inc., Cambridge, Massachusetts, USA
| | | | - Mar Santamaria
- Early Clinical Development, Pfizer, Inc., Cambridge, Massachusetts, USA
| | | | - David Caouette
- Early Clinical Development, Pfizer, Inc., Cambridge, Massachusetts, USA
| | - Kevin C Thomas
- Chobanian and Avedisian School of Medicine, Boston University, Boston, Massachusetts, USA
| |
Collapse
|
2
|
Psaltos DJ, Mamashli F, Adamusiak T, Demanuele C, Santamaria M, Czech MD. Wearable-Based Stair Climb Power Estimation and Activity Classification. Sensors (Basel) 2022; 22:6600. [PMID: 36081058 PMCID: PMC9459813 DOI: 10.3390/s22176600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 08/25/2022] [Accepted: 08/26/2022] [Indexed: 06/15/2023]
Abstract
Stair climb power (SCP) is a clinical measure of leg muscular function assessed in-clinic via the Stair Climb Power Test (SCPT). This method is subject to human error and cannot provide continuous remote monitoring. Continuous monitoring using wearable sensors may provide a more comprehensive assessment of lower-limb muscular function. In this work, we propose an algorithm to classify stair climbing periods and estimate SCP from a lower-back worn accelerometer, which strongly agrees with the clinical standard (r = 0.92, p < 0.001; ICC = 0.90, [0.82, 0.94]). Data were collected in-lab from healthy adults (n = 65) performing the four-step SCPT and a walking assessment while instrumented (accelerometer + gyroscope), which allowed us to investigate tradeoffs between sensor modalities. Using two classifiers, we were able to identify periods of stair ascent with >89% accuracy [sensitivity = >0.89, specificity = >0.90] using two ensemble machine learning algorithms, trained on accelerometer signal features. Minimal changes in model performances were observed using the gyroscope alone (±0−6% accuracy) versus the accelerometer model. While we observed a slight increase in accuracy when combining gyroscope and accelerometer (about +3−6% accuracy), this is tolerable to preserve battery life in the at-home environment. This work is impactful as it shows potential for an accelerometer-based at-home assessment of SCP.
Collapse
|